Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 6.236
Filtrar
3.
Circ Cardiovasc Imaging ; 17(5): e016267, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38771899

RESUMEN

BACKGROUND: Aortic valve calcification (AVC) indexation to the aortic annulus (AA) area measured by Doppler echocardiography (AVCdEcho) provides powerful prognostic information in patients with aortic stenosis (AS). However, the indexation by AA measured by multidetector computed tomography (AVCdCT) has never been evaluated. The aim of this study was to compare AVC, AVCdCT, and AVCdEcho with regard to hemodynamic correlations and clinical outcomes in patients with AS. METHODS: Data from 889 patients, mainly White, with calcific AS who underwent Doppler echocardiography and multidetector computed tomography within the same episode of care were retrospectively analyzed. AA was measured both by Doppler echocardiography and multidetector computed tomography. AVCdCT severity thresholds were established using receiver operating characteristic curve analyses in men and women separately. The primary end point was the occurrence of all-cause mortality. RESULTS: Correlations between gradient/velocity and AVCd were stronger (both P≤0.005) using AVCdCT (r=0.68, P<0.001 and r=0.66, P<0.001) than AVC (r=0.61, P<0.001 and r=0.60, P<0.001) or AVCdEcho (r=0.61, P<0.001 and r=0.59, P<0.001). AVCdCT thresholds for the identification of severe AS were 334 Agatston units (AU)/cm2 for women and 467 AU/cm2 for men. On a median follow-up of 6.62 (6.19-9.69) years, AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict all-cause mortality in multivariate analyses (hazard ratio [HR], 1.59 [95% CI, 1.26-2.00]; P<0.001 versus HR, 1.53 [95% CI, 1.11-1.65]; P=0.003 versus HR, 1.27 [95% CI, 1.11-1.46]; P<0.001; all likelihood test P≤0.004). AVCdCT ratio was superior to AVC ratio and AVCdEcho ratio to predict survival under medical treatment in multivariate analyses (HR, 1.80 [95% CI, 1.27-1.58]; P<0.001 compared with HR, 1.55 [95% CI, 1.13-2.10]; P=0.007; HR, 1.28 [95% CI, 1.03-1.57]; P=0.01; all likelihood test P<0.03). AVCdCT ratio predicts mortality in all subgroups of patients with AS. CONCLUSIONS: AVCdCT appears to be equivalent or superior to AVC and AVCdEcho to assess AS severity and predict all-cause mortality. Thus, it should be used to evaluate AS severity in patients with nonconclusive echocardiographic evaluations with or without low-flow status. AVCdCT thresholds of 300 AU/cm2 for women and 500 AU/cm2 for men seem to be appropriate to identify severe AS. Further studies are needed to validate these thresholds, especially in diverse populations.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Calcinosis , Ecocardiografía Doppler , Tomografía Computarizada Multidetector , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Tomografía Computarizada Multidetector/métodos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Estudios Retrospectivos , Anciano , Calcinosis/diagnóstico por imagen , Calcinosis/fisiopatología , Calcinosis/mortalidad , Ecocardiografía Doppler/métodos , Anciano de 80 o más Años , Pronóstico , Curva ROC , Hemodinámica , Persona de Mediana Edad , Factores de Riesgo
6.
Circ Cardiovasc Imaging ; 17(5): e015996, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38771906

RESUMEN

BACKGROUND: Extracellular volume fraction (ECV) is a marker for myocardial fibrosis and infiltration, can be quantified using cardiac computed tomography (ECVCT), and has prognostic utility in several diseases. This study aims to map out regional differences in ECVCT to obtain greater insights into the pathophysiological mechanisms of ECV expansion and its clinical implications. METHODS: Three prospective cohorts were included: patients with aortic stenosis (AS) and coexisting AS and transthyretin cardiac amyloidosis were referred for a transcatheter aortic valve replacement and had ECG-gated CT angiography and Technetium-99m-labelled 3,3-diphosphono-1,2-propanodicarboxylic acid scintigraphy to differentiate between the 2 cohorts. Controls had CT angiography and cardiac magnetic resonance demonstrating no significant coronary artery disease or infarction. Global and regional ECVCT was analyzed, and its association with mortality was assessed for patients with AS. RESULTS: In 199 patients, controls (n=65; 66% male), AS (n=115), and coexisting AS and transthyretin cardiac amyloidosis (n=19) had a global ECVCT of 26.1 (25.0-27.8%) versus 29.1 (27.5-31.1%) versus 37.4 (32.5-46.6%), respectively; P<0.001. Across cohorts, ECVCT was higher at the base (versus apex), the inferoseptum (versus anterolateral wall), and the subendocardium (versus subepicardium); P<0.05 for all. Among patients with AS, epicardial ECVCT, rather than any other regional value or global ECVCT, was the strongest predictor of mortality at a median of 3.9 (max 6.3) years (adjusted hazard ratio, 1.21 [95% CI, 1.08-1.36]; P=0.002). CONCLUSIONS: Regional differences in ECVCT suggest a predilection for fibrosis and amyloid infiltration at the base, subendocardium, inferior wall, and septum more than the anterior and lateral myocardium. ECVCT can predict long-term mortality with the subepicardium demonstrating the strongest discriminatory power. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifiers: NCT03029026 and NCT03094143.


Asunto(s)
Neuropatías Amiloides Familiares , Estenosis de la Válvula Aórtica , Angiografía por Tomografía Computarizada , Fibrosis , Miocardio , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Anciano , Estudios Prospectivos , Angiografía por Tomografía Computarizada/métodos , Anciano de 80 o más Años , Miocardio/patología , Neuropatías Amiloides Familiares/diagnóstico por imagen , Neuropatías Amiloides Familiares/complicaciones , Neuropatías Amiloides Familiares/mortalidad , Valor Predictivo de las Pruebas , Pronóstico , Angiografía Coronaria/métodos , Reemplazo de la Válvula Aórtica Transcatéter , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/patología , Cardiomiopatías/diagnóstico por imagen , Cardiomiopatías/fisiopatología , Persona de Mediana Edad
7.
Echocardiography ; 41(5): e15829, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38787527

RESUMEN

PURPOSE: Aortic stenosis (AS) is a common valvular heart disease with high morbidity and mortality. Recently, the association between peak atrial longitudinal strain (PALS) and AS clinical outcomes has been identified. This systematic review evaluates the prognostic value of PALS for adverse events in AS. METHODS: We performed a systematic literature review to identify clinical studies that evaluated Speckle-Tracking Echocardiography (STE)-derived PALS to predict adverse outcomes in patients with AS. We excluded studies that compared echocardiography to computed tomography and studies that focused on diseases other than AS. RESULTS: We included 18 studies reporting on 2660 patients. Patients with symptomatic AS had decreased PALS when compared to patients with asymptomatic AS. Patients with AS who had adverse events had decreased PALS when compared to patients with AS with no events. Each unit increase of PALS was independently associated with decreased risk for the primary endpoint. PALS cut-off values were associated with increased risk for the primary endpoint. CONCLUSION: This systematic review suggests PALS as an independent predictor for cardiovascular events in patients with AS and highlights the importance of evaluating LA mechanics for AS prognosis.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Atrios Cardíacos , Humanos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Pronóstico , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Femenino
8.
Open Heart ; 11(1)2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769066

RESUMEN

OBJECTIVE: Patients with moderate aortic stenosis (AS) exhibit high morbidity and mortality. Limited evidence exists on the role of aortic valve replacement (AVR) in this patient population. To investigate the benefit of AVR in moderate AS on survival and left ventricular function. METHODS: In a retrospective cohort study, patients with moderate AS between 2008 and 2016 were selected from the Cleveland Clinic echocardiography database and followed until 2018. Patients were classified as receiving AVR or managed medically (clinical surveillance). All-cause and cardiovascular mortality were assessed by survival analyses. Temporal haemodynamic and structural changes were assessed with longitudinal analyses using linear mixed effects models. RESULTS: We included 1421 patients (mean age, 75.3±5.4 years and 39.9% women) followed over a median duration of 6 years. Patients in the AVR group had lower risk of all-cause (adjusted HR (aHR)=0.51, 95% CI: 0.34 to 0.77; p=0.001) and cardiovascular mortality (aHR=0.50, 95% CI: 0.31 to 0.80; p=0.004) compared with those in the clinical surveillance group irrespective of sex, receipt of other open-heart surgeries and underlying malignancy. These findings were seen only in those with preserved left ventricular ejection fraction (LVEF) ≥50%. Further, patients in the AVR group had a significant trend towards an increase in LVEF and a decrease in right ventricular systolic pressure compared with those in the clinical surveillance group. CONCLUSIONS: In patients with moderate AS, AVR was associated with favourable clinical outcomes and left ventricular remodelling.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Función Ventricular Izquierda , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/diagnóstico , Femenino , Masculino , Estudios Retrospectivos , Anciano , Implantación de Prótesis de Válvulas Cardíacas/métodos , Función Ventricular Izquierda/fisiología , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Factores de Tiempo , Índice de Severidad de la Enfermedad , Estudios de Seguimiento , Factores de Riesgo , Ecocardiografía/métodos , Anciano de 80 o más Años , Tasa de Supervivencia/tendencias , Medición de Riesgo/métodos , Volumen Sistólico/fisiología
9.
Circ Cardiovasc Imaging ; 17(5): e016276, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38716653

RESUMEN

BACKGROUND: Quantification of left atrial (LA) conduit function and its contribution to left ventricular (LV) filling is challenging because it requires simultaneous measurements of both LA and LV volumes. The functional relationship between LA conduit function and the severity of diastolic dysfunction remains controversial. We studied the role of LA conduit function in maintaining LV filling in advanced diastolic dysfunction. METHODS: We performed volumetric and flow analyses of LA function across the spectrum of LV diastolic dysfunction, derived from a set of consecutive patients undergoing multiphasic cardiac computed tomography scanning (n=489). From LA and LV time-volume curves, we calculated 3 volumetric components: (1) early passive emptying volume; (2) late active (booster) volume; and (3) conduit volume. Results were prospectively validated on a group of patients with severe aortic stenosis (n=110). RESULTS: The early passive filling progressively decreased with worsening diastolic function (P<0.001). The atrial booster contribution to stroke volume modestly increases with impaired relaxation (P=0.021) and declines with more advanced diastolic function (P<0.001), thus failing to compensate for the reduction in early filling. The conduit volume increased progressively (P<0.001), accounting for 75% of stroke volume (interquartile range, 63-81%) with a restrictive filling pattern, compensating for the reduction in both early and booster functions. Similar results were obtained in patients with severe aortic stenosis. The pulmonary artery systolic pressure increased in a near-linear fashion when the conduit contribution to stroke volume increased above 60%. Maximal conduit flow rate strongly correlated with mitral E-wave velocity (r=0.71; P<0.0001), indicating that the increase in mitral E wave in diastolic dysfunction represents the increased conduit flow. CONCLUSIONS: An increase in conduit volume contribution to stroke volume represents a compensatory mechanism to maintain LV filling in advanced diastolic dysfunction. The increase in conduit volume despite increasing LV diastolic pressures is accomplished by an increase in pulmonary venous pressure.


Asunto(s)
Estenosis de la Válvula Aórtica , Función del Atrio Izquierdo , Diástole , Volumen Sistólico , Disfunción Ventricular Izquierda , Función Ventricular Izquierda , Humanos , Masculino , Femenino , Función del Atrio Izquierdo/fisiología , Anciano , Disfunción Ventricular Izquierda/fisiopatología , Disfunción Ventricular Izquierda/diagnóstico por imagen , Función Ventricular Izquierda/fisiología , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estudios Prospectivos , Volumen Sistólico/fisiología , Índice de Severidad de la Enfermedad , Atrios Cardíacos/fisiopatología , Atrios Cardíacos/diagnóstico por imagen , Persona de Mediana Edad , Anciano de 80 o más Años , Valor Predictivo de las Pruebas
10.
BMC Cardiovasc Disord ; 24(1): 253, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38750455

RESUMEN

BACKGROUND: Primary coronary slow flow (CSF) is defined as delayed opacification of the distal epicardial vasculature during coronary angiography in the absence of relevant coronary artery stenoses. Microvascular disease is thought to be the underlying cause of this pathology. Epicardial fat tissue (EFT) is an active endocrine organ directly surrounding the coronary arteries that provides pro-inflammatory factors to the adjacent tissue by paracrine and vasocrine mechanisms. The aim of the present study was to investigate a potential association between EFT and primary CSF and whether EFT can predict the presence of primary CSF. METHODS: Between 2016 and 2017, n = 88 patients with high-grade aortic stenosis who were planned for transcatheter aortic valve implantation (TAVI) were included in this retrospective study. EFT volume was measured by pre-TAVI computed tomography (CT) using dedicated software. The presence of primary CSF was defined based on the TIMI frame count from the pre-TAVI coronary angiograms. RESULTS: Thirty-nine of 88 TAVI patients had CSF (44.3%). EFT volume was markedly higher in patients with CSF (142 ml [IQR 107-180] vs. 113 ml [IQR 89-147]; p = 0.009) and was strongly associated with the presence of CSF (OR 1.012 [95%CI 1.002-1.021]; p = 0.014). After adjustment, EFT volume was still an independent predictor of CSF (OR 1.016 [95%CI 1.004-1.026]; p = 0.009). CONCLUSION: Primary CSF was independently associated with increased EFT volume. Further studies are needed to validate this finding and elucidate whether a causal relationship exists.


Asunto(s)
Tejido Adiposo , Estenosis de la Válvula Aórtica , Angiografía Coronaria , Circulación Coronaria , Pericardio , Valor Predictivo de las Pruebas , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Femenino , Masculino , Estudios Retrospectivos , Pericardio/diagnóstico por imagen , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Anciano , Tejido Adiposo/diagnóstico por imagen , Tejido Adiposo/fisiopatología , Anciano de 80 o más Años , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Válvula Aórtica/patología , Angiografía por Tomografía Computarizada , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Tejido Adiposo Epicárdico
11.
EuroIntervention ; 20(9): 579-590, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38726714

RESUMEN

BACKGROUND: Data on the performance of the latest-generation SAPIEN 3 Ultra RESILIA (S3UR) valve in patients who undergo transcatheter aortic valve replacement (TAVR) are scarce. AIMS: We aimed to assess the clinical outcomes, including valve performance, of the S3UR. METHODS: Registry data of 618 consecutive patients with S3UR and of a historical pooled cohort of 8,750 patients who had a SAPIEN 3 (S3) valve and underwent TAVR were collected. The clinical outcomes and haemodynamics, including patient-prosthesis mismatch (PPM), were compared between the 2 groups and in a propensity-matched cohort. RESULTS: The incidence of in-hospital death, vascular complications, and new pacemaker implantation was similar between the S3UR and the S3 groups (allp>0.05). However, both groups showed significant differences in the degrees of paravalvular leakage (PVL) (none-trivial: 87.0% vs 78.5%, mild: 12.5% vs 20.5%, ≥moderate: 0.5% vs 1.1%; p<0.001) and the incidence of PPM (none: 94.3% vs 85.1%, moderate: 5.2% vs 12.8%, severe: 0.5% vs 2.0%; p<0.001). The prevalence of a mean pressure gradient ≥20 mmHg was significantly lower in the S3UR group (1.6% vs 6.2%; p<0.001). Better haemodynamics were observed with the smaller 20 mm and 23 mm S3UR valves. The results were consistent in a matched cohort of patients with S3UR and with S3 (n=618 patients/group). CONCLUSIONS: The S3UR has equivalent procedural complications to the S3 but with lower rates of PVL and significantly better valve performance. The better valve performance of the S3UR, particularly in smaller valve sizes, overcomes the remaining issue of balloon-expandable valves after TAVR.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Femenino , Masculino , Anciano de 80 o más Años , Anciano , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Diseño de Prótesis , Hemodinámica , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Mortalidad Hospitalaria
12.
J Am Heart Assoc ; 13(9): e033872, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38700000

RESUMEN

BACKGROUND: The mortality risk attributable to moderate aortic stenosis (AS) remains incompletely characterized and has historically been underestimated. We aim to evaluate the association between moderate AS and all-cause death, comparing it with no/mild AS (in a general referral population and in patients with heart failure with reduced ejection fraction). METHODS AND RESULTS: A systematic review and pooled meta-analysis of Kaplan-Meier-derived reconstructed time-to-event data of studies published by June 2023 was conducted to evaluate survival outcomes among patients with moderate AS in comparison with individuals with no/mild AS. Ten studies were included, encompassing a total of 409 680 patients (11 527 with moderate AS and 398 153 with no/mild AS). In the overall population, the 15-year overall survival rate was 23.3% (95% CI, 19.1%-28.3%) in patients with moderate AS and 58.9% (95% CI, 58.1%-59.7%) in patients with no/mild aortic stenosis (hazard ratio [HR], 2.55 [95% CI, 2.46-2.64]; P<0.001). In patients with heart failure with reduced ejection fraction, the 10-year overall survival rate was 15.5% (95% CI, 10.0%-24.0%) in patients with moderate AS and 37.3% (95% CI, 36.2%-38.5%) in patients with no/mild AS (HR, 1.83 [95% CI, 1.69-2.0]; P<0.001). In both populations (overall and heart failure with reduced ejection fraction), these differences correspond to significant lifetime loss associated with moderate AS during follow-up (4.4 years, P<0.001; and 1.9 years, P<0.001, respectively). A consistent pattern of elevated mortality rate associated with moderate AS in sensitivity analyses of matched studies was observed. CONCLUSIONS: Moderate AS was associated with higher risk of death and lifetime loss compared with patients with no/mild AS.


Asunto(s)
Estenosis de la Válvula Aórtica , Humanos , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Índice de Severidad de la Enfermedad , Tasa de Supervivencia/tendencias , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Medición de Riesgo/métodos , Factores de Riesgo , Volumen Sistólico/fisiología , Causas de Muerte , Factores de Tiempo , Femenino , Anciano , Masculino
13.
J Am Heart Assoc ; 13(10): e034401, 2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38761080

RESUMEN

BACKGROUND: Coronary pressure indices to assess coronary artery disease are currently underused in patients with aortic stenosis due to many potential physiological effects that might hinder their interpretation. Studies with varying sample sizes have provided us with conflicting results on the effect of transcatheter aortic valve replacement (TAVR) on these indices. The aim of this meta-analysis was to study immediate and long-term effects of TAVR on fractional flow reserve (FFR) and nonhyperemic pressure ratios (NHPRs). METHODS AND RESULTS: Lesion-specific coronary pressure data were extracted from 6 studies, resulting in 147 lesions for immediate change in FFR analysis and 105 for NHPR analysis. To investigate the long-term changes, 93 lesions for FFR analysis and 68 for NHPR analysis were found. Lesion data were pooled and compared with paired t tests. Immediately after TAVR, FFR decreased significantly (-0.0130±0.0406 SD, P: 0.0002) while NHPR remained stable (0.0003±0.0675, P: 0.9675). Long-term after TAVR, FFR decreased significantly (-0.0230±0.0747, P: 0.0038) while NHPR increased nonsignificantly (0.0166±0.0699, P: 0.0543). When only borderline NHPR lesions were considered, this increase became significant (0.0249±0.0441, P: 0.0015). Sensitivity analysis confirmed our results in borderline lesions. CONCLUSIONS: TAVR resulted in small significant, but opposite, changes in FFR and NHPR. Using the standard cut-offs in patients with severe aortic stenosis, FFR might underestimate the physiological significance of a coronary lesion while NHPRs might overestimate its significance. The described changes only play a clinically relevant role in borderline lesions. Therefore, even in patients with aortic stenosis, an overtly positive or negative physiological assessment can be trusted.


Asunto(s)
Estenosis de la Válvula Aórtica , Reserva del Flujo Fraccional Miocárdico , Hiperemia , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/complicaciones , Enfermedad de la Arteria Coronaria/fisiopatología , Enfermedad de la Arteria Coronaria/cirugía , Enfermedad de la Arteria Coronaria/diagnóstico , Enfermedad de la Arteria Coronaria/complicaciones , Vasos Coronarios/fisiopatología , Reserva del Flujo Fraccional Miocárdico/fisiología , Hiperemia/fisiopatología , Resultado del Tratamiento
15.
PLoS One ; 19(5): e0303496, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38739622

RESUMEN

INTRODUCTION: Rheumatic heart disease (RHD), degenerative aortic stenosis (AS), and congenital valve diseases are prevalent in sub-Saharan Africa. Many knowledge gaps remain in understanding disease mechanisms, stratifying phenotypes, and prognostication. Therefore, we aimed to characterise patients through clinical profiling, imaging, histology, and molecular biomarkers to improve our understanding of the pathophysiology, diagnosis, and prognosis of RHD and AS. METHODS: In this cross-sectional, case-controlled study, we plan to recruit RHD and AS patients and compare them to matched controls. Living participants will undergo clinical assessment, echocardiography, CMR and blood sampling for circulatory biomarker analyses. Tissue samples will be obtained from patients undergoing valve replacement, while healthy tissues will be obtained from cadavers. Immunohistology, proteomics, metabolomics, and transcriptome analyses will be used to analyse circulatory- and tissue-specific biomarkers. Univariate and multivariate statistical analyses will be used for hypothesis testing and identification of important biomarkers. In summary, this study aims to delineate the pathophysiology of RHD and degenerative AS using multiparametric CMR imaging. In addition to discover novel biomarkers and explore the pathomechanisms associated with RHD and AS through high-throughput profiling of the tissue and blood proteome and metabolome and provide a proof of concept of the suitability of using cadaveric tissues as controls for cardiovascular disease studies.


Asunto(s)
Estenosis de la Válvula Aórtica , Biomarcadores , Cardiopatía Reumática , Humanos , Cardiopatía Reumática/diagnóstico por imagen , Cardiopatía Reumática/fisiopatología , Cardiopatía Reumática/metabolismo , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/metabolismo , Estenosis de la Válvula Aórtica/fisiopatología , Biomarcadores/metabolismo , Estudios de Casos y Controles , Estudios Transversales , Masculino , Femenino , Metabolómica/métodos , Ecocardiografía/métodos , Proteómica/métodos , Imagen por Resonancia Magnética/métodos , Multiómica
16.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658126

RESUMEN

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arteria Femoral , Estado de Salud , Prótesis Valvulares Cardíacas , Calidad de Vida , Recuperación de la Función , Índice de Severidad de la Enfermedad , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Femenino , Masculino , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Anciano , Anciano de 80 o más Años , Factores de Riesgo , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Medición de Riesgo , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Cateterismo Periférico/efectos adversos , Punciones , Diseño de Prótesis
17.
JACC Cardiovasc Interv ; 17(8): 992-1003, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38658128

RESUMEN

BACKGROUND: Extravalvular cardiac damage caused by aortic stenosis affects prognosis after transcatheter aortic valve replacement (TAVR). The long-term impact of changes in cardiac damage in response to relief from mechanical obstruction has not been fully investigated. OBJECTIVES: The authors aimed to investigate changes in cardiac damage early after TAVR and the prognostic impact of the cardiac damage classification after TAVR. METHODS: In this single-center observational study, patients undergoing transfemoral TAVR were retrospectively evaluated for cardiac damage before and after TAVR and classified into 5 stages of cardiac damage (0-4). RESULTS: Among 1,863 patients undergoing TAVR between January 2007 and June 2022, 56 patients (3.0%) were classified as stage 0, 225 (12.1%) as stage 1, 729 (39.1%) as stage 2, 388 (20.8%) as stage 3, and 465 (25.0%) as stage 4. Cardiac stage changed in 47.7% of patients (improved: 30.1% in stages 1-4 and deteriorated: 24.7% in stages 0-3) early after TAVR. Five-year all-cause mortality was associated with cardiac damage both at baseline (HRadjusted: 1.34; 95% CI: 1.24-1.44; P < 0.001 for linear trend) and after TAVR (HRadjusted: 1.40; 95% CI: 1.30-1.51; P < 0.001 for linear trend). Five-year all-cause mortality was stratified by changes in cardiac damage (improved, unchanged, or worsened) in patients with cardiac stage 2, 3, and 4 (log-rank P < 0.001 for stage 2, 0.005 for stage 3, and <0.001 for stage 4). CONCLUSIONS: The extent of extra-aortic valve cardiac damage before and after TAVR and changes in cardiac stage early after TAVR have important prognostic implications during long-term follow-up. (SwissTAVI Registry; NCT01368250).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/mortalidad , Masculino , Femenino , Estudios Retrospectivos , Factores de Tiempo , Anciano de 80 o más Años , Anciano , Factores de Riesgo , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Medición de Riesgo
18.
Int J Cardiol ; 407: 132103, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38677333

RESUMEN

BACKGROUND: Data regarding the prognostic value of left atrial (LA) strain in aortic stenosis (AS) is scarce, especially in Asian population and moderate AS. METHOD: Left ventricular global longitudinal strain (LVGLS), LA reservoir strain (LASr), conduit strain (LAScd), and contractile strain (LASct) were measured using automated speckle-tracking echocardiography in consecutive patients with moderate or severe AS. The primary endpoint was a composite of all-cause death (ACD) and major adverse cardiovascular events (MACE; myocardial infarction, syncope, and heart failure hospitalization). RESULTS: Of 712 patients (mean age, 78 ± 12 years; 370 [52%] moderate AS; 342 [48%] severe AS), average LV ejection fraction (LVEF) was 68 with SD of 12%. At a median follow-up of 18 months (interquartile range, 11-26 months), the primary endpoint occurred in 93 patients (60 deaths and 35 MACEs) and 221 patients underwent surgical or transcatheter aortic valve replacement (AVR). In the entire cohort, separate multivariable models adjusted for age, Charlson index, symptomatic status, time-dependent AVR, AS-severity, LA volume index and LVEF demonstrated that only LASr was associated with MACE+ACD (Hazard ratio, 0.97; P = 0.014). Subgroup analysis for MACE+ACD demonstrated consistent prognostication for LASr in moderate and severe AS; LVGLS was prognostic only in severe AS (all P ≤ 0.023). The optimal MACE+ACD cutoff for LASr from spline curves was 21.3%. Adjusted Kaplan-Meier curves demonstrated better event-free survival in patients with LASr >21.3% versus those with LASr ≤21.3% (P = 0.04). CONCLUSIONS: In both moderate and severe AS, only LASr robustly predicted outcomes; thus, including LASr in the AS staging algorithm should be considered.


Asunto(s)
Estenosis de la Válvula Aórtica , Pueblo Asiatico , Ecocardiografía , Índice de Severidad de la Enfermedad , Humanos , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico , Masculino , Femenino , Anciano , Pronóstico , Anciano de 80 o más Años , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/fisiopatología , Estudios de Seguimiento , Función Ventricular Izquierda/fisiología , Función del Atrio Izquierdo/fisiología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Estudios de Cohortes
19.
Medicina (Kaunas) ; 60(4)2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38674313

RESUMEN

Background and Objectives: The combination of aortic valve stenosis (AS) and ischemic heart disease (IHD) is quite common and is associated with myocardial fibrosis (MF). The purpose of this study was to evaluate the association between the histologically verified left ventricular (LV) MF and its geometry and function in isolated AS and AS within IHD groups. Materials and Methods: In a single-center, prospective trial, 116 patients underwent aortic valve replacement (AVR) with/without concomitant surgery. The study population was divided into groups of isolated AS with/without IHD. Echocardiography was used, and LV measurements and aortic valve parameters were obtained from all patients. Myocardial tissue was procured from all study patients undergoing elective surgery. Results: There were no statistical differences between isolated AS and AS+IHD groups in LV parameters or systolic and diastolic functions during the study periods. The collagen volume fraction was significantly different between the isolated AS and AS+IHD groups and was 7.3 ± 5.6 and 8.3 ± 6.4, respectively. Correlations between MF and left ventricular end-diastolic diameter (LVEDD) (r = 0.59, p = < 0.001), left ventricular mass (LVM) (r = 0.42, p = 0.011), left ventricular ejection fraction (LVEF) (r = -0.67, p < 0.001) and an efficient orifice area (EOA) (r = 0.371, p = 0.028) were detected in isolated AS during the preoperative period; the same was observed for LVEDD (r = 0.45, p = 0.002), LVM (r = 0.36, p = 0.026), LVEF (r = -0.35, p = 0.026) and aortic annulus (r = 0.43, p = 0.018) in the early postoperative period; and LVEDD (r = 0.35, p ≤ 0.05), LVM (r = 0.43, p = 0.007) and EOA (r = 0.496, p = 0.003) in the follow-up period. In the group of AS and IHD, correlations were found only with LV posterior wall thickness (r = 0.322, p = 0.022) in the follow-up period. Conclusions: Histological MF in AS was correlated with LVM and LVEDD in all study periods. No correlations between MF and LV parameters were found in aortic stenosis in the ischemic heart disease group across all study periods.


Asunto(s)
Estenosis de la Válvula Aórtica , Ecocardiografía , Fibrosis , Ventrículos Cardíacos , Humanos , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/complicaciones , Masculino , Femenino , Persona de Mediana Edad , Estudios Prospectivos , Anciano , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/patología , Ecocardiografía/métodos , Miocardio/patología , Función Ventricular Izquierda/fisiología , Isquemia Miocárdica/fisiopatología , Isquemia Miocárdica/complicaciones
20.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577931

RESUMEN

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Prótesis Valvulares Cardíacas , Hemodinámica , Diseño de Prótesis , Sistema de Registros , Reemplazo de la Válvula Aórtica Transcatéter , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Complicaciones Posoperatorias , Estudios Prospectivos , Recuperación de la Función , Factores de Riesgo , España , Factores de Tiempo , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA