Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 189
Filtrar
1.
CNS Neurosci Ther ; 30(9): e70043, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39258798

RESUMEN

AIMS: Transcutaneous auricular vagus nerve stimulation (taVNS) is widely used to treat a variety of disorders because it is noninvasive, safe, and well tolerated by awake patients. However, long-term and repetitive taVNS is difficult to achieve in awake mice. Therefore, developing a new taVNS method that fully mimics the method used in clinical settings and is well-tolerated by awake mice is greatly important for generalizing research findings related to the effects of taVNS. The study aimed to develop a new taVNS device for use in awake mice and to test its reliability and effectiveness. METHODS: We demonstrated the reliability of this taVNS device through retrograde neurotropic pseudorabies virus (PRV) tracing and evaluated its effectiveness through morphological analysis. After 3 weeks of taVNS application, the open field test (OFT) and elevated plus maze (EPM) were used to evaluate anxiety-like behaviors, and the Y-maze test and novel object recognition test (NORT) were used to evaluate recognition memory behaviors, respectively. RESULTS: We found that repetitive taVNS was well tolerated by awake mice, had no effect on anxiety-like behaviors, and significantly improved memory. CONCLUSION: Our findings suggest that this new taVNS device for repetitive stimulation of awake mice is safe, tolerable, and effective.


Asunto(s)
Estudios de Factibilidad , Estimulación Eléctrica Transcutánea del Nervio , Estimulación del Nervio Vago , Vigilia , Animales , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Vigilia/fisiología , Masculino , Estimulación Eléctrica Transcutánea del Nervio/métodos , Estimulación Eléctrica Transcutánea del Nervio/instrumentación , Ratones , Ratones Endogámicos C57BL , Aprendizaje por Laberinto/fisiología , Ansiedad/terapia , Reconocimiento en Psicología/fisiología , Prueba de Campo Abierto , Herpesvirus Suido 1
2.
Nat Commun ; 15(1): 7993, 2024 Sep 12.
Artículo en Inglés | MEDLINE | ID: mdl-39266583

RESUMEN

Electroceuticals, through the selective modulation of peripheral nerves near target organs, are promising for treating refractory diseases. However, the small sizes and the delicate nature of these nerves present challenges in simplifying the fixation and stabilizing the electrical-coupling interface for neural electrodes. Herein, we construct a robust neural interface for fine peripheral nerves using an injectable bio-adhesive hydrogel bioelectronics. By incorporating a multifunctional molecular regulator during network formation, we optimize the injectability and conductivity of the hydrogel through fine-tuning reaction kinetics and multi-scale interactions within the conductive network. Meanwhile, the mechanical and electrical stability of the hydrogel is achieved without compromising its injectability. Minimal tissue damage along with low and stable impedance of the injectable neural interface enables chronic vagus neuromodulation for myocardial infarction therapy in the male rat model. Our highly-stable, injectable, conductive hydrogel bioelectronics are readily available to target challenging anatomical locations, paving the way for future precision bioelectronic medicine.


Asunto(s)
Conductividad Eléctrica , Hidrogeles , Animales , Masculino , Hidrogeles/química , Ratas , Ratas Sprague-Dawley , Infarto del Miocardio/terapia , Inyecciones , Modelos Animales de Enfermedad , Nervio Vago/fisiología , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Nervios Periféricos/fisiología
3.
Card Electrophysiol Clin ; 16(3): 315-324, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39084724

RESUMEN

The cardiac autonomic nervous system plays a key role in maintaining normal cardiac physiology, and once disrupted, it worsens the cardiac disease states. Neuromodulation therapies have been emerging as new treatment options, and various techniques have been introduced to mitigate autonomic nervous imbalances to help cardiac patients with their disease conditions and symptoms. In this review article, we discuss various neuromodulation techniques used in clinical settings to treat cardiac diseases.


Asunto(s)
Cardiopatías , Humanos , Cardiopatías/terapia , Cardiopatías/fisiopatología , Sistema Nervioso Autónomo/fisiopatología , Sistema Nervioso Autónomo/fisiología , Corazón/fisiología , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Estimulación del Nervio Vago/instrumentación
5.
Sensors (Basel) ; 24(10)2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38794024

RESUMEN

An electroceutical is a medical device that uses electrical signals to control biological functions. It can be inserted into the human body as an implant and has several crucial advantages over conventional medicines for certain diseases. This research develops a new vagus nerve simulation (VNS) electroceutical through an innovative approach to overcome the communication limitations of existing devices. A phased array antenna with a better communication performance was developed and applied to the electroceutical prototype. In order to effectively respond to changes in communication signals, we developed the steering algorithm and firmware, and designed the smart communication protocol that operates at a low power that is safe for the patients. This protocol is intended to improve a communication sensitivity related to the transmission and reception distance. Based on this technical approach, the heightened effectiveness and safety of the prototype have been ascertained, with the actual clinical tests using live animals. We confirmed the signal attenuation performance to be excellent, and a smooth communication was achieved even at a distance of 7 m. The prototype showed a much wider communication range than any other existing products. Through this, it is conceivable that various problems due to space constraints can be resolved, hence presenting many benefits to the patients whose last resort to the disease is the VNS electroceutical.


Asunto(s)
Algoritmos , Nervio Vago , Nervio Vago/fisiología , Animales , Humanos , Prótesis e Implantes , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Procesamiento de Señales Asistido por Computador
6.
Seizure ; 118: 65-70, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38642446

RESUMEN

INTRODUCTION: For patients with drug-resistant epilepsy (DRE) who are not suitable for surgical resection, neuromodulation with vagus nerve stimulation (VNS) is an established approach. However, there is limited evidence of seizure reduction when replacing traditional VNS (tVNS) device with a cardiac-based one (cbVNS). This meta-analysis compares the seizure reduction achieved by replacing tVNS with cbVNS in a population with DRE. METHODS: We systematically searched PubMed, Embase, and Cochrane Central following PRISMA guidelines. The main outcomes were number of patients experiencing a ≥ 50 % and ≥80 % reduction in seizures, as defined by the McHugh scale. Additionally, we assessed the number of patients achieving freedom from seizures. RESULTS: We included 178 patients with DRE from 7 studies who were initially treated with tVNS and subsequently had it replaced by cbVNS. The follow-up for cbVNS ranged from 6 to 37.5 months. There was a statistically significant reduction in seizure frequency with the replacement of tVNS by cbVNS, using a ≥ 50 % (OR 1.79; 95 % CI 1.07 to 2.97; I²=0 %; p = 0.03) and a ≥ 80 % (OR 2.06; 95 % CI 1.17 to 3.62; I²=0 %; p = 0.01) reduction threshold. Nineteen (13 %) participants achieved freedom from seizures after switching to cbVNS. There was no difference in the rate of freedom from seizures between groups (OR 1.85; 95 % CI 0.81 to 4.21; I²=0 %; p = 0.14). CONCLUSION: In patients with DRE undergoing battery replacement, cbVNS might be associated with seizure reduction (≥50 % and ≥80 % threshold) after switching from tVNS. Randomised controlled trials are necessary to validate these findings.


Asunto(s)
Convulsiones , Estimulación del Nervio Vago , Humanos , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Convulsiones/terapia , Epilepsia Refractaria/terapia
7.
Acta Neurochir (Wien) ; 166(1): 193, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38662025

RESUMEN

Vagal neuropathy causing vocal fold palsy is an uncommon complication of vagal nerve stimulator (VNS) placement. It may be associated with intraoperative nerve injury or with device stimulation. Here we present the first case of delayed, compressive vagal neuropathy associated with VNS coil placement which presented with progressive hoarseness and vocal cord paralysis. Coil removal and vagal neurolysis was performed to relieve the compression. Larger 3 mm VNS coils were placed for continuation of therapy. Coils with a larger inner diameter should be employed where possible to prevent this complication. The frequency of VNS-associated vagal nerve compression may warrant further investigation.


Asunto(s)
Estimulación del Nervio Vago , Parálisis de los Pliegues Vocales , Humanos , Masculino , Síndromes de Compresión Nerviosa/etiología , Síndromes de Compresión Nerviosa/cirugía , Nervio Vago , Enfermedades del Nervio Vago/etiología , Enfermedades del Nervio Vago/cirugía , Estimulación del Nervio Vago/efectos adversos , Estimulación del Nervio Vago/instrumentación , Estimulación del Nervio Vago/métodos , Parálisis de los Pliegues Vocales/etiología , Anciano
8.
Artículo en Inglés | MEDLINE | ID: mdl-38530712

RESUMEN

In the emerging research field of bioelectronic medicine, it has been indicated that neuromodulation of the vagus nerve (VN) has the potential to treat various conditions such as epilepsy, depression, and autoimmune diseases. In order to reduce side effects, as well as to increase the effectiveness of the delivered therapy, sub-fascicle stimulation specificity is required. In the electrical domain, increasing spatial selectivity can only be achieved using invasive and potentially damaging approaches like compressive forces or nerve penetration. To avoid these invasive methods while obtaining a high spatial selectivity, a 2-mm diameter extraneural cuff-shaped proof-of-concept design with integrated lead zirconate titanate (PZT) based ultrasound (US) transducers is proposed in this article. For the development of the proposed concept, wafer-level microfabrication techniques are employed. Moreover, acoustic measurements are performed on the device, in order to characterize the ultrasonic beam profiles of the integrated PZT-based US transducers. A focal spot size of around [Formula: see text] is measured for the proposed cuff. Moreover, the curvature of the device leads to constructive interference of the US waves originating from multiple PZT-based US transducers, which in turn leads to an increase of 45% in focal pressure compared to the focal pressure of a single PZT-based US transducer. Integrating PZT-based US transducers in an extraneural cuff-shaped design has the potential to achieve high-precision US neuromodulation of the VN without requiring intraneural implantation.


Asunto(s)
Diseño de Equipo , Estudios de Factibilidad , Transductores , Estimulación del Nervio Vago , Nervio Vago , Estimulación del Nervio Vago/instrumentación , Estimulación del Nervio Vago/métodos , Nervio Vago/fisiología , Nervio Vago/diagnóstico por imagen , Nervio Vago/efectos de la radiación , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Humanos , Plomo , Titanio , Circonio
9.
Neurotherapeutics ; 21(3): e00339, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38430811

RESUMEN

Prader-Willi syndrome (PWS) is a complex, genetic disorder characterized by multisystem involvement, including hyperphagia, maladaptive behaviors and endocrinological derangements. Recent developments in advanced neuroimaging have led to a growing understanding of PWS as a neural circuit disorder, as well as subsequent interests in the application of neuromodulatory therapies. Various non-invasive and invasive device-based neuromodulation methods, including vagus nerve stimulation (VNS), transcranial direct current stimulation (tDCS), repetitive transcranial magnetic stimulation (rTMS), and deep brain stimulation (DBS) have all been reported to be potentially promising treatments for addressing the major symptoms of PWS. In this systematic literature review, we summarize the recent literature that investigated these therapies, discuss the underlying circuits which may underpin symptom manifestations, and cover future directions of the field. Through our comprehensive search, there were a total of 47 patients who had undergone device-based neuromodulation therapy for PWS. Two articles described VNS, 4 tDCS, 1 rTMS and 2 DBS, targeting different symptoms of PWS, including aberrant behavior, hyperphagia and weight. Multi-center and multi-country efforts will be required to advance the field given the low prevalence of PWS. Finally, given the potentially vulnerable population, neuroethical considerations and dialogue should guide the field.


Asunto(s)
Estimulación Encefálica Profunda , Síndrome de Prader-Willi , Estimulación Transcraneal de Corriente Directa , Estimulación Magnética Transcraneal , Estimulación del Nervio Vago , Humanos , Síndrome de Prader-Willi/terapia , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Estimulación Magnética Transcraneal/métodos , Estimulación Encefálica Profunda/métodos , Estimulación Encefálica Profunda/instrumentación , Estimulación Transcraneal de Corriente Directa/métodos
10.
Brain Stimul ; 17(2): 382-391, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38499287

RESUMEN

BACKGROUND: Vagus nerve stimulation (VNS) at low frequencies (≤30 Hz) has been an established treatment for drug-resistant epilepsy (DRE) for over 25 years. OBJECTIVE: To examine the initial safety and efficacy performance of an investigational, high-frequency (≥250 Hz) VNS paradigm herein called "Microburst VNS" (µVNS). µVNS consists of short, high-frequency bursts of electrical pulses believed to preferentially modulate certain brain regions. METHODS: Thirty-three (33) participants were enrolled into an exploratory feasibility study, 21 with focal-onset seizures and 12 with generalized-onset seizures. Participants were titrated to a personalized target dose of µVNS using an investigational fMRI protocol. Participants were then followed for up to 12 months, with visits every 3 months, and monitored for side-effects at all time points. This study was registered as NCT03446664 on February 27th, 2018. RESULTS: The device was well-tolerated. Reported adverse events were consistent with typical low frequency VNS outcomes and tended to diminish in severity over time, including dysphonia, cough, dyspnea, and implant site pain. After 12 months of µVNS, the mean seizure frequency reduction for all seizures was 61.3% (median reduction: 70.4%; 90% CI of median: 48.9%-83.3%). The 12-month responder rate (≥50% reduction) was 63.3% (90% CI: 46.7%-77.9%) and the super-responder rate (≥80% reduction) was 40% (90% CI: 25.0%-56.6%). Participants with focal-onset seizures appeared to benefit similarly to participants with generalized-onset seizures (mean reduction in seizures at 12 months: 62.6% focal [n = 19], versus 59.0% generalized [n = 11]). CONCLUSION: Overall, µVNS appears to be safe and potentially a promising therapeutic alternative to traditional VNS. It merits further investigation in randomized controlled trials which will help determine the impact of investigational variables and which patients are most suitable for this novel therapy.


Asunto(s)
Epilepsia Refractaria , Estudios de Factibilidad , Estimulación del Nervio Vago , Humanos , Masculino , Femenino , Estimulación del Nervio Vago/métodos , Estimulación del Nervio Vago/instrumentación , Estimulación del Nervio Vago/efectos adversos , Adulto , Epilepsia Refractaria/terapia , Persona de Mediana Edad , Adulto Joven , Epilepsia Generalizada/terapia , Epilepsia Generalizada/fisiopatología , Resultado del Tratamiento , Epilepsias Parciales/terapia , Epilepsias Parciales/fisiopatología , Adolescente , Imagen por Resonancia Magnética
11.
Artículo en Inglés | MEDLINE | ID: mdl-38109242

RESUMEN

This article discusses the design and development of a wearable and portable ultrasound auricular nerve stimulator. The device is in the form of a headset that presses against the cymba concha depression in the ear and stimulates the auricular vagus nerve with ultrasound energy. This article reviews the development, design, and material structures for such a system, including the characterization of the working prototypes. The devices are being supplied to various organizations and universities for clinical trials, in which effectiveness will be assessed. The device is light, compact, and an effective neurostimulator to induce calm. To the best of our knowledge, the device is the first fully built ultrasonic auricular nerve stimulator in the world.


Asunto(s)
Diseño de Equipo , Estimulación del Nervio Vago , Dispositivos Electrónicos Vestibles , Humanos , Estimulación del Nervio Vago/instrumentación , Estimulación del Nervio Vago/métodos , Nervio Vago/fisiología
12.
J Neural Eng ; 19(6)2022 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-36356313

RESUMEN

Objective.Vagus nerve stimulation (VNS) is a promising approach for the treatment of a wide variety of debilitating conditions, including autoimmune diseases and intractable epilepsy. Much remains to be learned about the molecular mechanisms involved in vagus nerve regulation of organ function. Despite an abundance of well-characterized rodent models of common chronic diseases, currently available technologies are rarely suitable for the required long-term experiments in freely moving animals, particularly experimental mice. Due to challenging anatomical limitations, many relevant experiments require miniaturized, less invasive, and wireless devices for precise stimulation of the vagus nerve and other peripheral nerves of interest. Our objective is to outline possible solutions to this problem by using nongenetic light-based stimulation.Approach.We describe how to design and benchmark new microstimulation devices that are based on transcutaneous photovoltaic stimulation. The approach is to use wired multielectrode cuffs to test different stimulation patterns, and then build photovoltaic stimulators to generate the most optimal patterns. We validate stimulation through heart rate analysis.Main results.A range of different stimulation geometries are explored with large differences in performance. Two types of photovoltaic devices are fabricated to deliver stimulation: photocapacitors and photovoltaic flags. The former is simple and more compact, but has limited efficiency. The photovoltaic flag approach is more elaborate, but highly efficient. Both can be used for wireless actuation of the vagus nerve using light impulses.Significance.These approaches can enable studies in small animals that were previously challenging, such as long-termin vivostudies for mapping functional vagus nerve innervation. This new knowledge may have potential to support clinical translation of VNS for treatment of select inflammatory and neurologic diseases.


Asunto(s)
Estimulación del Nervio Vago , Tecnología Inalámbrica , Animales , Ratones , Estimulación del Nervio Vago/instrumentación
13.
Am Surg ; 88(3): 525-527, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33026229

RESUMEN

BACKGROUND: Refractory seizure activity represents a difficult problem for both patients and practitioners. Implantation of the vagal nerve stimulator has been posited as an effective treatment for refractory seizure activity. These devices are inserted by placing leads into the carotid sheath along the vagus nerve. We evaluated a vascular surgeon's experience placing vagal nerve stimulators. METHODS: We examined all patients treated with placement of vagal nerve stimulator by a single surgeon from October 2016 to October 2018. Data collected included demographics, medical and surgical history, intraoperative variables, and complications. RESULTS: Thirty-four patients underwent placement of a vagal nerve stimulator. About 29.4% had a previous vagal nerve stimulator placed on the ipsilateral side. Intraoperative bradycardia was seen in 1 patient. Postoperative complications were identified in 5 patients, all of which were transient dysphagia or changes in voice quality which did not require intervention. There was no significant difference between patients with the previous operation and those without for developing postoperative complications (P = .138). Average blood loss was higher in patients who had undergone previous stimulator placement than those who had not (P = .0223), and the operative time was longer (P ≤ .0001). DISCUSSION: Given the anatomical location of placement, vascular surgeons may be called upon to place these devices. In our single surgeon series, we found that the placement was safe, with minimal complications. Intraoperatively, this case appears to be more difficult (with higher blood loss and longer operative time) in patients who have had previous device placement, but this does not appear to lead to increased complications.


Asunto(s)
Epilepsia Refractaria/terapia , Implantación de Prótesis/métodos , Cirujanos , Estimulación del Nervio Vago/instrumentación , Adulto , Anciano , Pérdida de Sangre Quirúrgica/estadística & datos numéricos , Bradicardia/epidemiología , Arterias Carótidas , Trastornos de Deglución/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Tempo Operativo , Complicaciones Posoperatorias/epidemiología , Implantación de Prótesis/efectos adversos , Implantación de Prótesis/estadística & datos numéricos , Estudios Retrospectivos
14.
Emerg Med Clin North Am ; 39(3): 641-660, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34215407

RESUMEN

There are a growing number of medically complex children with implanted devices. Emergency physicians with a basic knowledge of these devices can troubleshoot and fix many of the issues that may arise. Recognition of malfunction of these devices can reduce morbidity and mortality among this special population. In this article, we review common issues that may arise in children with gastrostomy tubes, central nervous system shunts, cochlear implants, and vagal nerve stimulators.


Asunto(s)
Derivaciones del Líquido Cefalorraquídeo/efectos adversos , Implantes Cocleares/efectos adversos , Nutrición Enteral/efectos adversos , Estimulación del Nervio Vago/efectos adversos , Encéfalo/diagnóstico por imagen , Niño , Servicio de Urgencia en Hospital , Falla de Equipo , Gastrostomía/efectos adversos , Humanos , Infecciones/diagnóstico , Infecciones/etiología , Anamnesis , Medicina de Urgencia Pediátrica , Examen Físico , Estimulación del Nervio Vago/instrumentación
15.
Life Sci ; 282: 119805, 2021 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-34237313

RESUMEN

AIMS: Widespread pain and headache are common in Gulf War Illness with suboptimal treatments available. We tested the efficacy of non-invasive, transcutaneous vagal nerve stimulation (nVNS) for relief of widespread pain and migraine in Gulf War Veterans with GWI. MAIN METHODS: A 10-week double-blind, randomized controlled trial of nVNS used the gammaCore (ElectroCore, Inc.) compared to sham stimulation with the same device followed by a 10-week open-label follow up with active nVNS. The primary outcome was a numerical pain rating at the end of the blinded period. Secondary outcomes included physical function, migraine frequency and severity, and impression of change during the blinded and open-label periods. Two-factor MANOVA models tested for significant differences between groups from baseline to end of the blinded period and during the open-label period. KEY FINDINGS: Among 27 participants enrolled and issued a nVNS device, there was a slight improvement in pain ratings from baseline to the end of the blinded phase [6.18 (±0.82) vs. 5.05 (±2.3); p = 0.040] which did not differ between active and sham nVNS. Physical function was also slightly improved overall without group differences. There were no significant changes in migraine frequency or severity during the blinded period. Twenty participants started in the open-label phase; no statistically significant changes in pain, physical function, migraine measures, or impression of change were noted during this phase. SIGNIFICANCE: Veterans with GWI actively treated with nVNS reported no improvement in either widespread pain or migraine frequency or severity relative to Veterans with GWI who received sham nVNS.


Asunto(s)
Dolor Crónico/terapia , Síndrome del Golfo Pérsico/terapia , Estimulación del Nervio Vago/métodos , Adulto , Dolor Crónico/etiología , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Síndrome del Golfo Pérsico/complicaciones , Resultado del Tratamiento , Estimulación del Nervio Vago/efectos adversos , Estimulación del Nervio Vago/instrumentación , Veteranos
16.
Acta Otolaryngol ; 141(7): 719-723, 2021 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-34003719

RESUMEN

BACKGROUND: With the large number of VNS implants performed worldwide, the need for removal or replacement of the device in selected cases is emerging, this removal or replacement of VNS can be challenging. AIMS/OBJECTIVE: To describe the feasibility and safety of revising vagal nerve stimulation surgery in terms of the indications, surgical techniques, and outcomes. MATERIALS AND METHODS: A retrospective study, a series of eight cases with VNS implants that needed revision surgery have been reviewed, four devices were completely removed and four were only revised. The revision surgery was performed after a range of 7 months to 6 years, due to different reasons. Initial surgeries and revisions were performed at the otolaryngology department in a major tertiary center. CONCLUSIONS AND SIGNIFICANCE: We concluded that the previously implanted vagal nerve stimulation electrodes can be completely removed without any significant sequelae on the nerve. It may also be re-implanted safely at the previously used segment of the vagus nerve with a similar outcome in seizure control as the initial implantation.


Asunto(s)
Remoción de Dispositivos , Electrodos Implantados , Epilepsia/terapia , Reoperación/métodos , Estimulación del Nervio Vago/instrumentación , Nervio Vago/cirugía , Adolescente , Adulto , Niño , Preescolar , Falla de Equipo , Femenino , Humanos , Masculino , Estudios Retrospectivos
17.
Elife ; 102021 04 06.
Artículo en Inglés | MEDLINE | ID: mdl-33821789

RESUMEN

Vagus nerve stimulation (VNS) suppresses inflammation and autoimmune diseases in preclinical and clinical studies. The underlying molecular, neurological, and anatomical mechanisms have been well characterized using acute electrophysiological stimulation of the vagus. However, there are several unanswered mechanistic questions about the effects of chronic VNS, which require solving numerous technical challenges for a long-term interface with the vagus in mice. Here, we describe a scalable model for long-term VNS in mice developed and validated in four research laboratories. We observed significant heart rate responses for at least 4 weeks in 60-90% of animals. Device implantation did not impair vagus-mediated reflexes. VNS using this implant significantly suppressed TNF levels in endotoxemia. Histological examination of implanted nerves revealed fibrotic encapsulation without axonal pathology. This model may be useful to study the physiology of the vagus and provides a tool to systematically investigate long-term VNS as therapy for chronic diseases modeled in mice.


Asunto(s)
Electrodos Implantados/estadística & datos numéricos , Ratones/fisiología , Estimulación del Nervio Vago/instrumentación , Nervio Vago/fisiología , Animales , Fenómenos Electrofisiológicos , Masculino , Ratones Endogámicos C57BL , Modelos Animales
18.
Lancet ; 397(10284): 1545-1553, 2021 04 24.
Artículo en Inglés | MEDLINE | ID: mdl-33894832

RESUMEN

BACKGROUND: Long-term loss of arm function after ischaemic stroke is common and might be improved by vagus nerve stimulation paired with rehabilitation. We aimed to determine whether this strategy is a safe and effective treatment for improving arm function after stroke. METHODS: In this pivotal, randomised, triple-blind, sham-controlled trial, done in 19 stroke rehabilitation services in the UK and the USA, participants with moderate-to-severe arm weakness, at least 9 months after ischaemic stroke, were randomly assigned (1:1) to either rehabilitation paired with active vagus nerve stimulation (VNS group) or rehabilitation paired with sham stimulation (control group). Randomisation was done by ResearchPoint Global (Austin, TX, USA) using SAS PROC PLAN (SAS Institute Software, Cary, NC, USA), with stratification by region (USA vs UK), age (≤30 years vs >30 years), and baseline Fugl-Meyer Assessment-Upper Extremity (FMA-UE) score (20-35 vs 36-50). Participants, outcomes assessors, and treating therapists were masked to group assignment. All participants were implanted with a vagus nerve stimulation device. The VNS group received 0·8 mA, 100 µs, 30 Hz stimulation pulses, lasting 0·5 s. The control group received 0 mA pulses. Participants received 6 weeks of in-clinic therapy (three times per week; total of 18 sessions) followed by a home exercise programme. The primary outcome was the change in impairment measured by the FMA-UE score on the first day after completion of in-clinic therapy. FMA-UE response rates were also assessed at 90 days after in-clinic therapy (secondary endpoint). All analyses were by intention to treat. This trial is registered at ClinicalTrials.gov, NCT03131960. FINDINGS: Between Oct 2, 2017, and Sept 12, 2019, 108 participants were randomly assigned to treatment (53 to the VNS group and 55 to the control group). 106 completed the study (one patient for each group did not complete the study). On the first day after completion of in-clinic therapy, the mean FMA-UE score increased by 5·0 points (SD 4·4) in the VNS group and by 2·4 points (3·8) in the control group (between group difference 2·6, 95% CI 1·0-4·2, p=0·0014). 90 days after in-clinic therapy, a clinically meaningful response on the FMA-UE score was achieved in 23 (47%) of 53 patients in the VNS group versus 13 (24%) of 55 patients in the control group (between group difference 24%, 6-41; p=0·0098). There was one serious adverse event related to surgery (vocal cord paresis) in the control group. INTERPRETATION: Vagus nerve stimulation paired with rehabilitation is a novel potential treatment option for people with long-term moderate-to-severe arm impairment after ischaemic stroke. FUNDING: MicroTransponder.


Asunto(s)
Neuroestimuladores Implantables/efectos adversos , Accidente Cerebrovascular Isquémico/complicaciones , Rehabilitación de Accidente Cerebrovascular/métodos , Extremidad Superior/fisiopatología , Estimulación del Nervio Vago/instrumentación , Anciano , Estudios de Casos y Controles , Terapia Combinada/métodos , Terapia por Ejercicio/métodos , Femenino , Humanos , Accidente Cerebrovascular Isquémico/rehabilitación , Masculino , Persona de Mediana Edad , Evaluación de Resultado en la Atención de Salud , Paresia/etiología , Recuperación de la Función/fisiología , Resultado del Tratamiento , Parálisis de los Pliegues Vocales/epidemiología
19.
Acta Neurochir (Wien) ; 163(5): 1365-1368, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-32970237

RESUMEN

OBJECTIVE: Vagal nerve stimulation (VNS) therapy is among the growing options in the treatment of intractable epilepsy. The phenomenon of surprise lead impedance issues found at the time of surgery resulting in unplanned lead revision is a challenge with this type of device. We reviewed our experience with VNS revisions. MATERIAL AND METHODS: We retrospectively reviewed the records of all adult and pediatric patients between January 2009 and September 2018 who underwent surgery for VNS therapy, including revision surgery. Office and operative notes were reviewed to obtain the indications and operative details for VNS placement. RESULTS: A total of 570 operations were reviewed. The indication was intractable epilepsy in all cases. Primary implantation was performed in 232 patients, while the remaining 338 cases were revision cases of various natures. Surprise high lead impedance was found in 10 (3%) of these cases, resulting in a significantly increased complexity of surgery in those instances. CONCLUSION: Lead impedance issues can be caused by disconnection, electrode fracture, hardware failure, or tissue scarring but ultimately require a more extended surgery than may be initially planned. Anticipating the potential for a more extensive operation than a simple generator replacement may prevent perioperative frustrations on both sides.


Asunto(s)
Impedancia Eléctrica , Reoperación , Estimulación del Nervio Vago/instrumentación , Adulto , Niño , Electrodos , Humanos , Estudios Retrospectivos
20.
Clin Neurol Neurosurg ; 200: 106333, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33203592

RESUMEN

BACKGROUND: Vagal Nerve Stimulation (VNS) is one of the most common neuro-modulation based approaches for the treatment of medically intractable epilepsy. Despite advances in technology and surgical techniques, hardware infection remains a recognized and feared complication in VNS placement. Management of such infections is scarce in the literature with the majority of data available in case reports. It ranges from immediate removal of the VNS device to conservative treatment with antibiotics in an attempt to salvage the device, particularly in patients who demonstrated significant improvement in seizure frequency and quality of life. METHODS: We performed a review of the literature in accordance with PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines to identify reported cases of salvaged VNS infection. A literature search for relevant English articles was conducted using Medline. References of relevant articles were also reviewed. Articles that comprised an attempt to salvage an infected VNS were included. RESULTS: We obtained 12 articles describing an attempt to salvage an infected VNS. Out of a total of 62 reported VNS infections and 43 salvage attempts using a variety of antibiotic-based approaches, 17 cases were successfully salvaged and 26 cases failed the salvage attempt and had to be explanted eventually. Moreover, we report a case of an 18-year-old male with Lennox-Gastaut syndrome who presented21 days after VNS placement with a MRSA deep tissue infection. An attempt was made to treat the infection with long-term culture-based intravenous antibiotics, but it recurred three years later with neck wound dehiscence and positive wound culture for the same organism, and ex-plantation was thus performed. CONCLUSION: The management of VNS infections remains a dilemma for neurosurgeons. Although the idea of salvaging an infected VNS seems appealing, hardware removal seems to be inevitable despite adequate antibiotic treatment.


Asunto(s)
Síndrome de Lennox-Gastaut/terapia , Complicaciones Posoperatorias/terapia , Infecciones Relacionadas con Prótesis/terapia , Terapia Recuperativa/métodos , Estimulación del Nervio Vago/efectos adversos , Adolescente , Epilepsia Refractaria/diagnóstico por imagen , Epilepsia Refractaria/terapia , Humanos , Síndrome de Lennox-Gastaut/diagnóstico por imagen , Masculino , Complicaciones Posoperatorias/diagnóstico por imagen , Infecciones Relacionadas con Prótesis/diagnóstico por imagen , Recurrencia , Factores de Tiempo , Estimulación del Nervio Vago/instrumentación
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...