Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 12.640
Filtrar
1.
Molecules ; 29(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38731551

RESUMEN

The aim of this study is to solve the problems of the complicated pretreatment and high analytical cost in the detection technology of trace drugs and their metabolites in municipal wastewater. A high-performance magnetic sorbent was fsynthesized for the enrichment of trace drugs and their metabolites in wastewater to develop a magnetic solid-phase extraction pretreatment combined with the acoustic ejection mass spectrometry (AEMS) analytical method. The magnetic nanospheres were successfully prepared by magnetic nanoparticles modified with divinylbenzene and vinylpyrrolidone. The results showed that the linear dynamic range of 17 drugs was 1-500 ng/mL, the recovery was 44-100%, the matrix effect was more than 51%, the quantification limit was 1-2 ng/mL, and the MS measurement was fast. It can be seen that the developed magnetic solid-phase extraction (MSPE) method is a good solution to the problems of the complicated pretreatment and analytical cost in the analysis of drugs in wastewater. The developed magnetic material and acoustic excitation pretreatment coupled with mass spectrometry analysis method can realize the low-cost, efficient enrichment, and fast analysis of different kinds of drug molecules in urban sewage.


Asunto(s)
Drogas Ilícitas , Espectrometría de Masas , Aguas del Alcantarillado , Extracción en Fase Sólida , Aguas del Alcantarillado/análisis , Aguas del Alcantarillado/química , Extracción en Fase Sólida/métodos , Espectrometría de Masas/métodos , Drogas Ilícitas/análisis , Contaminantes Químicos del Agua/análisis , Aguas Residuales/análisis , Aguas Residuales/química , Nanopartículas de Magnetita/química
2.
Molecules ; 29(9)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38731605

RESUMEN

The aim of this study is to develop a rapid and accurate method for simultaneous analysis of multi-residue pesticides and conduct pesticide monitoring in agricultural products produced by the production and distribution stage in Korea. The representative agricultural products were selected as brown rice, soybean, potato, mandarin, and green pepper and developed using gas chromatography with tandem mass (GC-MS/MS) for the analysis of 272 pesticide residues. The experimental samples were extracted by the QuEChERS-EN method and then cleaned up by using d-SPE, including MgSO4 and primary secondary amine (PSA) sorbents. The established method was validated in accordance with Codex CAC-GL/40, and the limit of quantitation (LOQ) was determined to be 0.01 mg/kg. A total of 243 pesticides satisfied the guidelines in five samples at three levels with values of 60 to 120% (recovery) and ≤45% (coefficient of variation, CV). The remaining 29 pesticides did not satisfy the guidelines, and these pesticides are expected to be used as a screening method for the routine inspection of agricultural products. As a result of analyzing 223 agricultural products in South Korea by applying the simultaneous analysis method, none of the detected levels in the samples exceeded the standard values based on maximum residue limits (MRLs). The developed method in this study will be used to inspect residual pesticides in agricultural products, and it is anticipated to contribute to the distribution of safe agricultural products to consumers.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Residuos de Plaguicidas , Espectrometría de Masas en Tándem , Espectrometría de Masas en Tándem/métodos , Residuos de Plaguicidas/análisis , Cromatografía de Gases y Espectrometría de Masas/métodos , Plaguicidas/análisis , Productos Agrícolas/química , República de Corea , Contaminación de Alimentos/análisis , Límite de Detección , Extracción en Fase Sólida/métodos
3.
Anal Methods ; 16(19): 3142-3153, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38713147

RESUMEN

We develop and validate a method for the rapid determination and identification of 20 ß-lactamase antibiotics traces in goat's milk by combining the solid phase extraction technology with ultra-high performance liquid chromatography-tandem mass spectrometry. Goat milk samples were extracted with acetonitrile twice. The supernatant was then extracted and cleaned by solid-phase extraction using divinylbenzene and N-vinylpyrrolidone copolymer. The method was validated, with limits of quantification (LOQs) of 0.3 µg kg-1, specificities of 1/3 LOQ, linearities (R2) > 0.99, recoveries of 80-110%, repeatabilities <10.0%, and intermediate precisions <10.0%. The developed method was suitable for the routine analysis of ß-lactamase antibiotics residues in goat's milk and was used to test 76 goat milk samples produced in China.


Asunto(s)
Antibacterianos , Cabras , Leche , Extracción en Fase Sólida , Espectrometría de Masas en Tándem , beta-Lactamasas , Animales , Extracción en Fase Sólida/métodos , Leche/química , Espectrometría de Masas en Tándem/métodos , Antibacterianos/análisis , Cromatografía Líquida de Alta Presión/métodos , Límite de Detección , Reproducibilidad de los Resultados , Residuos de Medicamentos/análisis , Contaminación de Alimentos/análisis , Cromatografía Líquida con Espectrometría de Masas
4.
J Chromatogr A ; 1725: 464943, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38691924

RESUMEN

In this study, we proposed a novel method utilizing polyethyleneimine (PEI)-modified halloysite nanotubes (HNTs)-based hybrid silica monolithic spin tip to analyze hydrophilic ß-lactam antibiotics and ß-lactamases inhibitors in whole blood samples for the first time. HNTs were incorporated directly into the hybrid silica monolith via a sol-gel method, which improved the hydrophilicity of the matrix. The as-prepared monolith was further modified with PEI by glutaraldehyde coupling reaction. It was found that the PEI-modified HNTs-based hybrid silica monolith enabled a large adsorption capacity of cefoperazone at 35.7 mg g-1. The monolithic spin tip-based purification method greatly reduced the matrix effect of whole blood samples and had a detection limit as low as 0.1 - 0.2 ng mL-1. In addition, the spiked recoveries of sulbactam, cefuroxime, and cefoperazone in blank whole blood were in the range of 89.3-105.4 % for intra-day and 90.6-103.5 % for inter-day, with low relative standard deviations of 1.3-7.2 % and 4.9-10.5 %, respectively. This study introduces a new strategy for preparing nanoparticles incorporated in a hybrid silica monolith with a high adsorption capacity. Moreover, it offers a valuable tool to monitor sulbactam, cefoperazone, and cefuroxime in whole blood from pregnant women with the final aim of guiding their administration.


Asunto(s)
Cefoperazona , Cefuroxima , Interacciones Hidrofóbicas e Hidrofílicas , Límite de Detección , Nanotubos , Dióxido de Silicio , Extracción en Fase Sólida , Sulbactam , Cefoperazona/sangre , Cefoperazona/química , Humanos , Sulbactam/sangre , Sulbactam/química , Extracción en Fase Sólida/métodos , Dióxido de Silicio/química , Nanotubos/química , Cefuroxima/sangre , Cefuroxima/química , Arcilla/química , Adsorción , Antibacterianos/sangre , Antibacterianos/química , Polietileneimina/química , Cromatografía Líquida de Alta Presión/métodos , Reproducibilidad de los Resultados
5.
Food Res Int ; 187: 114359, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38763643

RESUMEN

Chinese Xiaokeng green tea (XKGT) possesses elegant and fascinating aroma characteristics, but its key odorants are still unknown. In this study, 124 volatile compounds in the XKGT infusion were identified by headspace-solid phase microextraction (HS-SPME), stir bar sorptive extraction (SBSE), and solvent extraction-solid phase extraction (SE-SPE) combined with gas chromatography-mass spectrometry (GC-MS). Comparing these three pretreatments, we found HS-SPME was more efficient for headspace compounds while SE-SPE was more efficient for volatiles with higher boiling points. Furthermore, SBSE showed more sensitive to capture ketones then was effective to the application of pretreatment of aroma analysis in green tea. The aroma intensities (AIs) were further identified by gas chromatography-olfactometry (GC-O). According to the AI and relative odor activity value (rOAV), 27 compounds were identified as aroma-active compounds. Quantitative descriptive analysis (QDA) showed that the characteristic aroma attributes of XKGT were chestnut-like, corn-like, fresh, and so on. The results of network analysis showed that (E, Z)-2,6-nonadienal, nonanal, octanal and nerolidol were responsible for the fresh aroma. Similarly, dimethyl sulfide, (E, E)-2,4-heptadienal, (E)-2-octenal and ß-cyclocitral contributed to the corn-like aroma. Furthermore, indole was responsible for the chestnut-like and soybean-like aroma. This study contributes to a better understanding of the molecular mechanism of the aroma characteristics of XKGT.


Asunto(s)
Cromatografía de Gases y Espectrometría de Masas , Odorantes , Olfatometría , Microextracción en Fase Sólida , , Compuestos Orgánicos Volátiles , Odorantes/análisis , Té/química , Compuestos Orgánicos Volátiles/análisis , Microextracción en Fase Sólida/métodos , Humanos , Camellia sinensis/química , Extracción en Fase Sólida/métodos
6.
J Pharm Biomed Anal ; 245: 116161, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38714135

RESUMEN

In this study, Fe3O4@ZnCr-layered double hydroxide/zeolitic imidazolate frameworks-8 (MLDH/ZIF-8) magnetically functionalized composites were synthesized by co-precipitation and in situ growth based on the advantages of LDHs and ZIF-8 using Fe3O4 nanoparticles as a magnetic substrate to obtain adsorbents with excellent performance. Moreover, the composite was used for the efficient enrichment of flavonoids in Chinese herbal medicines. The internal structures and surface properties were characterized by SEM, Fourier transform infrared spectroscopy, X-ray diffraction and so on. MLDH/ZIF-8 exhibited a large specific surface area and good paramagnetic properties. The MLDH/ZIF-8 magnetic composite was used as a magnetic solid-phase extraction (MSPE) adsorbent, and a MLDH/ZIF-8 MSPE-pressurized capillary electrochromatography coupling method was developed for the separation and detection of flavonoids (luteolin, kaempferol and apigenin) in a sample of the Chinese herb Ohwia caudata (Thunberg) H. Ohashi. The relevant parameters affecting the extraction efficiency were optimized to determine the ideal conditions for MSPE. 5 mg of adsorbent in sample solution at pH 6, vortex extraction for 5 min, elution with 1.5 mL of ethyl acetate for 15 min. The method showed good linearity in the concentration range of 3-50 µg mL-1 with correlation coefficients of 0.9934-0.9981, and displayed a relatively LODs of 0.07-0.09 µg mL-1. The spiked recoveries of all analytes ranged from 84.5% to 122.0% with RSDs (n=3) between 4.5% and 7.7%. This method is straightforward and efficient, with promising potential in the separation and analysis of active ingredients in various Chinese herbal medicines.


Asunto(s)
Medicamentos Herbarios Chinos , Flavonoides , Hidróxidos , Extracción en Fase Sólida , Flavonoides/aislamiento & purificación , Flavonoides/análisis , Flavonoides/química , Extracción en Fase Sólida/métodos , Hidróxidos/química , Medicamentos Herbarios Chinos/química , Adsorción , Nanopartículas de Magnetita/química , Estructuras Metalorgánicas/química , Espectroscopía Infrarroja por Transformada de Fourier/métodos
7.
J Chromatogr A ; 1726: 464965, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38733925

RESUMEN

Aristolochic acids (AAs) naturally occurring in the herbal genus Aristolochia are associated with a high risk of kidney failure, multiple tumors and cancers. However, approaches with high selectivity and rapidity for measuring AAs in biological samples are still inadequate. Inspired by the mechanism of AAs-induced nephrotoxicity, we designed a hybrid magnetic polymer-porous agarose (denoted as MNs@SiO2M@DNV-A), mimicking the effect of basic and aromatic residues of organic anion transporter 1 (OAT1) for efficient enriching aristolochic acid I (AA I) and aristolochic acid II (AA II) in the plasma. The monomers of vinylbenzyl trimethylammonium chloride (VBTAC), N-vinyl-2-pyrrolidinone (NVP) and divinylbenzene (DVB) were employed to construct the polymer layer, which provided a selective adsorption for AAs by multiple interactions. The porous agarose shell contributed to remove interfering proteins in the plasma samples. A magnetic solid-phase extraction (MSPE) based on the proposed composite enhanced the selectivity toward AA I and AA II in the plasma samples. In combination of HPLC analysis, the proposed method was proved to be applicable to fast and specific quantification of AAs in blood samples, which was characterized by a good linearity, high sensitivity, acceptable recovery, excellent repeatability and satisfactory reusability.


Asunto(s)
Ácidos Aristolóquicos , Compuestos de Amonio Cuaternario , Sefarosa , Extracción en Fase Sólida , Ácidos Aristolóquicos/química , Ácidos Aristolóquicos/aislamiento & purificación , Ácidos Aristolóquicos/sangre , Sefarosa/química , Extracción en Fase Sólida/métodos , Compuestos de Amonio Cuaternario/química , Cromatografía Líquida de Alta Presión/métodos , Porosidad , Límite de Detección , Animales , Humanos , Polímeros/química , Adsorción , Reproducibilidad de los Resultados
8.
Environ Sci Technol ; 58(19): 8518-8530, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38693060

RESUMEN

Wastewater-based epidemiology (WBE) has been widely implemented around the world as a complementary tool to conventional surveillance techniques to inform and improve public health responses. Currently, wastewater surveillance programs in the U.S. are evaluating integrated approaches to address public health challenges across multiple domains, including substance abuse. In this work, we demonstrated the potential of online solid-phase extraction coupled with liquid chromatography-high-resolution mass spectrometry to support targeted quantification and nontargeted analysis of psychoactive and lifestyle substances as a step toward understanding the operational feasibility of a statewide wastewater surveillance program for substance use assessment in New York. Target screening confirmed 39 substances in influent samples collected from 10 wastewater treatment plants with varying sewershed characteristics and is anticipated to meet the throughput demands as the statewide program scales up to full capacity. Nontarget screening prioritized additional compounds for identification at three confidence levels, including psychoactive substances, such as opioid analgesics, phenethylamines, and cathinone derivatives. Consumption rates of 12 target substances detected in over 80% of wastewater samples were similar to those reported by previous U.S.-based WBE studies despite the uncertainty associated with back-calculations. For selected substances, the relative bias in consumption estimates was sensitive to variations in monitoring frequency, and factors beyond human excretion (e.g., as indicated by the parent-to-metabolite ratios) might also contribute to their prevalence at the sewershed scale. Overall, our study marks the initial phase of refining analytical workflows and data interpretation in preparation for the incorporation of substance use assessment into the statewide wastewater surveillance program in New York.


Asunto(s)
Aguas Residuales , Aguas Residuales/química , New York , Humanos , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente/métodos , Trastornos Relacionados con Sustancias/epidemiología , Extracción en Fase Sólida
9.
Chemosphere ; 358: 142201, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38692367

RESUMEN

Thallium (Tl) is a potential toxicity element that poses significant ecological and environmental risks. Recently, a substantial amount of Tl has been released into the environment through natural and human activities, which attracts increasing attention. The determination of this hazardous and trace element is crucial for controlling its pollution. This article summarizes the advancement and progress in optimizing Tl detection techniques, including atomic absorption spectroscopy (AAS), voltammetry, inductively coupled plasma (ICP)-based methods, spectrophotometry, and X-ray-based methods. Additionally, it introduces sampling and pretreatment methods such as diffusive gradients in thin films (DGT), liquid-liquid extraction, solid phase extraction, and cloud point extraction. Among these techniques, ICP-mass spectrometry (MS) is the preferred choice for Tl detection due to its high precision in determining Tl as well as its species and isotopic composition. Meanwhile, some new materials and agents are employed in detection. The application of novel work electrode materials and chromogenic agents is discussed. Emphasis is placed on reducing solvent consumption and utilizing pretreatment techniques such as ultrasound-assisted processes and functionalized magnetic particles. Most detection is performed in aqueous matrices, while X-ray-based methods applied to solid phases are summarized which provide non-destructive analysis. This work improves the understanding of Tl determination technology while serving as a valuable resource for researchers seeking appropriate analytical techniques.


Asunto(s)
Monitoreo del Ambiente , Talio , Talio/análisis , Monitoreo del Ambiente/métodos , Contaminantes Ambientales/análisis , Espectrofotometría Atómica , Extracción en Fase Sólida/métodos , Espectrometría de Masas/métodos , Extracción Líquido-Líquido/métodos
10.
Mikrochim Acta ; 191(6): 297, 2024 05 06.
Artículo en Inglés | MEDLINE | ID: mdl-38709347

RESUMEN

A new detection platform based on a hydroxylated covalent organic framework (COF) integrated with liquid chromatography-tandem mass spectrometry (LC-MS/MS) was constructed and used for detecting adrenergic receptor agonists (ARAs) residues in milk. The hydroxylated COF was prepared by polymerization of tris(4-aminophenyl)amine and 1,3,5-tris(4-formyl-3-hydroxyphenyl)benzene and applied to solid-phase extraction (SPE) of ARAs. This hydroxylated COF was featured with hierarchical flower-like morphology, easy preparation, and copious active adsorption sites. The adsorption model fittings and molecular simulation were applied to explore the potential adsorption mechanism. This detection platform was suitable for detecting four α2- and five ß2-ARAs residues in milk. The linear ranges of the ARAs were from 0.25 to 50 µg·kg-1; the intra-day and the inter-day repeatability were in the range 2.9-7.9% and 2.0-10.1%, respectively. This work demonstrates this hydroxylated COF has great potential as SPE cartridge packing, and provides a new way to determine ARAs residues in milk.


Asunto(s)
Leche , Extracción en Fase Sólida , Espectrometría de Masas en Tándem , Extracción en Fase Sólida/métodos , Leche/química , Animales , Espectrometría de Masas en Tándem/métodos , Hidroxilación , Estructuras Metalorgánicas/química , Adsorción , Agonistas Adrenérgicos/química , Agonistas Adrenérgicos/análisis , Límite de Detección , Bovinos
11.
Food Res Int ; 183: 114240, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38760119

RESUMEN

Polycyclic aromatic hydrocarbons (PAHs) are carcinogenic organic pollutants found in various environments, notably aquatic ecosystems and the food chain, posing significant health risks. Traditional methods for detecting PAHs in food involve complex processes and considerable reagent usage, raising environmental concerns. This study explores eco-friendly approaches suing solid phases derived from natural sources in matrix solid phase dispersion. We aimed to develop, optimize, and validate a sample preparation technique for seafood, employing natural materials for PAH analysis. Ten natural phases were compared with a commercial reference phase. The methodology involved matrix solid phase dispersion and pressurized liquid extraction, followed by liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS). Three solid phases (perlite, sweet manioc starch, and barley) showed superior performance in LC-MS/MS and were further evaluated with gas chromatography-tandem mass spectrometry (GC-MS/MS), confirming perlite as the most effective phase. Validation followed Brazilian regulatory guidelines and European Community Regulation 2021/808/EC. The resulting method offered advantages in cost-effectiveness, reduced environmental impact, cleaner extracts, and enhanced analytical performance compared to the reference solid phase and LC-MS/MS. Proficiency analysis confirmed method reliability, with over 50% alignment with green analytical chemistry principles. In conclusion, this study developed an environmentally sustainable sample preparation technique for seafood analysis using natural solid phases, particularly perlite, for PAH determination.


Asunto(s)
Contaminación de Alimentos , Cromatografía de Gases y Espectrometría de Masas , Hidrocarburos Policíclicos Aromáticos , Alimentos Marinos , Espectrometría de Masas en Tándem , Hidrocarburos Policíclicos Aromáticos/análisis , Alimentos Marinos/análisis , Espectrometría de Masas en Tándem/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Cromatografía Liquida/métodos , Contaminación de Alimentos/análisis , Extracción en Fase Sólida/métodos , Reproducibilidad de los Resultados , Brasil , Tecnología Química Verde/métodos
12.
Anal Chim Acta ; 1308: 342662, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38740449

RESUMEN

BACKGROUND: The ongoing infusion of pharmaceutical and personal care products (PPCPs) into ecosystems sustains a perpetual life cycle and leads to multi-generational exposures. Limited understanding of their environmental impact and their intrinsic ability to induce physiological effect in humans, even at low doses, pose great risks to human health. Few scholarly works have conducted systematic research into the occurrence of PPCPs within potable water systems. Concurrently, the associated monitoring techniques have not been comprehensively examined with regards to the specific nature of drinking water, namely whether the significant presence of disinfectants may influence the detection of PPCPs. RESULTS: A modified approach in terms of detailed investigation of sample preservation and optimization of an in-lab fabricated solid phase extraction (SPE) cartridge filled with DVB-VP and PS-DVB sorbent was proposed. Favorable methodological parameters were achieved, with correlation coefficients spanning from 0.9866 to 0.9998. The LODs of the PPCPs fluctuated from 0.001 to 2 µg L-1, while the LOQs varied from 0.002 to 5 µg L-1. The analysis of spiked samples disclosed a methodological precision of 2.31-9.86 % and a recovery of 52.4-119 %. We utilized the established method for analyzing 14 water samples of three categories (source water, finished water and tap water) from five centralized water supply plants. A total of 24 categories encompassing 72 PPCPs were detected, with the concentrations of PPCPs manifested a marked decrease from source water to finished water and finally to tap water. SIGNIFICANCE: Our research meticulously examined the enhancement and purification effects of widely used commercial SPE cartridges and suggested the use of in-lab fabricated SPE cartridges packed with DVB-VP and PS-DVB adsorbents. We also conducted a systematic evaluation of the need to incorporate ascorbic acid and sodium thiosulfate as preservatives for PPCP measurement, in consideration of the unique characteristics of drinking water matrices, specifically, the significant concentration levels of disinfectants. Furthermore, the proposed method was effectively employed to study the presence of PPCPs in source water, finished water, and tap water collected from centralized water supply plants.


Asunto(s)
Extracción en Fase Sólida , Contaminantes Químicos del Agua , Extracción en Fase Sólida/métodos , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/aislamiento & purificación , Preparaciones Farmacéuticas/análisis , Abastecimiento de Agua , Agua Potable/análisis , Cosméticos/análisis , Cosméticos/química , Monitoreo del Ambiente/métodos
13.
J Sep Sci ; 47(9-10): e2300925, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38726740

RESUMEN

Deep eutectic solvents (DESs), as a new type of eco-friendly solvent, have attracted increasing attention on the extraction and separation of flavonoid compounds from various samples, owing to their excellent properties such as biodegradability and ease of handling with very low toxicity. This article provides a status review of the applications of DESs in the extraction of flavonoids, including the introduction of flavonoid compounds, the properties and superiority of DESs, and extraction methods (ultrasonic-assisted extraction, heating reflux extraction, matrix solid-phase dispersion, and solid-phase extraction). Finally, prospects and challenges in the application of DESs on extraction and separation are extensively elucidated and critically reviewed.


Asunto(s)
Disolventes Eutécticos Profundos , Flavonoides , Extracción en Fase Sólida , Flavonoides/aislamiento & purificación , Flavonoides/química , Disolventes Eutécticos Profundos/química , Solventes/química
14.
J Chromatogr A ; 1725: 464957, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38703458

RESUMEN

This study focuses on the purification and detection of glufosinate (GLUF) and its metabolites N-acetyl GLUF and MPP in plasma samples. A Dikma Polyamino HILIC column was used for the effective retention and separation of GLUF and its metabolites, and the innovative addition of a low concentration of ammonium fluoride solution to the mobile phase effectively improved the detection sensitivity of the target analytes. Monodisperse core-shell weak cation exchange (WCX)/C18 bifunctional magnetic polymer composites (Fe3O4@WCX/C18) were prepared in a controllable manner, and their morphology and composition were fully characterized. The Fe3O4@WCX/C18 microspheres were used as a magnetic solid-phase extraction (MSPE) adsorbent for the sample purification and detection of GLUF and its metabolites in plasma samples combined with liquid chromatography-tandem mass spectrometry (LC-MS/MS). The purification conditions of Fe3O4@WCX/C18 microspheres for GLUF and its metabolites in spiked plasma samples were optimized to achieve the best MSPE efficiency. The purification mechanisms of the target analytes in plasma samples include electrostatic attraction and hydrophobic interactions. Furthermore, the effect of the molar ratio of the two functional monomers 4-VBA and 1-octadecene in the adsorbent was optimized and it shows that the bifunctional components WCX/C18 have a synergistic effect on the determination of GLUF and its metabolites in plasma samples. In addition, the present study compared the purification performance of the Fe3O4@WCX/C18 microsphere-based MSPE method with that of the commercial Oasis WCX SPE method, and the results showed that the Fe3O4@WCX/C18 microsphere-based MSPE method established in this work had a stronger ability to remove matrix interferences. Under optimal purification conditions, the recoveries of GLUF and its metabolites in plasma were 87.6-111 % with relative standard deviations (RSDs) ranging from 0.2 % to 4.8 %. The limits of detection (LODs, S/N≥3) and limits of quantification (LOQs, S/N≥10) were 0.10-0.18 µg/L and 0.30-0.54 µg/L, respectively. The MSPE-LC-MS/MS method developed in this study is fast, simple, accurate and sensitive and can be used to confirm GLUF intoxication based not only on the detection of the GLUF prototype but also on the detection of its two metabolites.


Asunto(s)
Aminobutiratos , Extracción en Fase Sólida , Espectrometría de Masas en Tándem , Extracción en Fase Sólida/métodos , Espectrometría de Masas en Tándem/métodos , Aminobutiratos/sangre , Aminobutiratos/química , Cromatografía Liquida/métodos , Límite de Detección , Polímeros/química , Animales , Microesferas , Adsorción , Ratas , Cromatografía por Intercambio Iónico/métodos
15.
Chemosphere ; 358: 142227, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38704046

RESUMEN

The widespread detection of perfluorooctanoic acid (PFOA) in the environment has raised significant concerns. The standard PFOA analytical method relies on expensive solid-phase extraction (SPE) and liquid chromatography tandem mass spectrometry (LC-MS/MS) instruments, making routine use prohibitive. We herein proposed a cost-effective yet novel enrichment method for determining PFOA at ng L-1 level. This method entailed a two-step sample preparation process: firstly, PFOA was extracted and enriched using a forward-extraction under acidic conditions, followed by a backward-extraction and enrichment step utilizing alkaline water. The enriched samples were subsequently subjected to a common ion chromatography (IC). Results reveal that maintaining a forward-extraction pH below its pKa value (2.8) is essential, as protonated PFOA proves effective in enhancing the enrichment factor (EF). The challenge lied in driving PFOA from forward-extractant to aqueous backward-extractant due to the decreased hydrophobicity of deprotonated PFOA (log Kow2 = 1.0). In addition, we found that evaporating forward-extractant with alkaline backward-extractant (containing 5% methanol) reduced potential analytical uncertainties associated with PFOA evaporation and sorption. Under optimal conditions, the method achieved a detection limit of 9.2 ng L-1 and an impressive EF value of 719. Comparison with SPE-LC-MS/MS confirmed the proposed method as a promising alternative for PFOA determination. Although initially targeted for PFOA, the novel methodology is likely applicable to preconcentration of other poly-fluoroalkyl substances.


Asunto(s)
Caprilatos , Fluorocarburos , Extracción Líquido-Líquido , Espectrometría de Masas en Tándem , Contaminantes Químicos del Agua , Caprilatos/análisis , Caprilatos/química , Fluorocarburos/análisis , Fluorocarburos/aislamiento & purificación , Fluorocarburos/química , Contaminantes Químicos del Agua/análisis , Espectrometría de Masas en Tándem/métodos , Extracción Líquido-Líquido/métodos , Cromatografía Liquida/métodos , Extracción en Fase Sólida/métodos , Agua/química , Monitoreo del Ambiente/métodos
16.
Rapid Commun Mass Spectrom ; 38(11): e9738, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38572671

RESUMEN

RATIONALE: Accurate identification of old rice samples from new ones benefits their market circulation and consumers. However, the current detection methods are still not satisfactory because of their insufficient accuracy or (and) time-consuming process. METHODS: Chelating carboxylic acids (CCAs) were selectively extracted from rice, by stirring with chelating resin and a dilute Na2CO3 solution. The green analytical chemistry guidelines for sample preparation were investigated by using the green chemistry calculator AGREE prep. The extractant was determined by liquid chromatography-mass spectrometry (LC/MS), and statistical analysis of the analytical data was carried out to evaluate the significance of the difference by ChiPlot. RESULTS: The limit of quantitation for the CCAs is in the range of 1 to 50 ng/mL, with a reasonable reproducibility. The CCAs in 23 rice samples were determined within a wide concentration range from 0.03 to 1174 µg/g. Intriguingly, the content of citric acid, malonic acid, α-ketoglutaric acid and cis-aconite acid in new rice was each found to be distinctively higher than that in old rice by several times. Even mixtures of old and new rice were found to show much difference in the concentration of citric acid and malic acid. CONCLUSION: A green analytical method has been developed for the simultaneous determination of CCAs by LC/MS analysis, and the identification of old rice samples from new ones was easily carried out according to their CCA content for the first time. The results indicated that the described method has powerful potential for the accurate identification of old rice samples from new ones.


Asunto(s)
Cromatografía Líquida con Espectrometría de Masas , Oryza , Cromatografía Liquida/métodos , Ácidos Carboxílicos , Oryza/química , Espectrometría de Masas en Tándem/métodos , Reproducibilidad de los Resultados , Ácido Cítrico , Cromatografía Líquida de Alta Presión/métodos , Extracción en Fase Sólida
17.
Wei Sheng Yan Jiu ; 53(2): 288-293, 2024 Mar.
Artículo en Chino | MEDLINE | ID: mdl-38604966

RESUMEN

OBJECTIVE: To establish a method for the simultaneous determination of 6 benzodiazepine sedatives residue in aquatic products by high performance liquid chromatography-triple quadrupole mass spectrometry. METHODS: The samples were extracted with acetonitrile and purified by C_(18 )solid phase extraction column. The sample solution was separated by Waters ACQUITY UPLC BEH C_(18 )column(2.1 mm×50 mm, 1.7 µm) using 0.1% formic acid and methanol as mobile phase for gradient elution, determined in multiple reaction monitoring mode and quantified by internal standard method. RESULTS: Six benzodiazepine sedatives had a good linear relationship in the range of 1.0-50.0 µg/L with r>0.9990, the limits of detection and limits of quantification were 0.3 and 1.0 µg/kg. Average recoveries for the analytes at 3 spiked levels ranged from 74.2%-108.0% with relative standard deviations of 1.1%-6.7%(n=6). CONCLUSION: The method is simple, rapid, sensitive and accurate, which is suitable for simultaneous determination of 6 benzodiazepine sedatives residue in aquatic products.


Asunto(s)
Cromatografía Líquida con Espectrometría de Masas , Espectrometría de Masas en Tándem , Cromatografía Líquida de Alta Presión , Extracción en Fase Sólida , Hipnóticos y Sedantes
18.
Wei Sheng Yan Jiu ; 53(2): 310-315, 2024 Mar.
Artículo en Chino | MEDLINE | ID: mdl-38604969

RESUMEN

OBJECTIVE: To establish a method for twelve halobenzoquinones(HBQs) in drinking water by solid phase extraction-ultra-performance liquid chromatography coupled with electrospray-tandem mass spectrometry(SPE-UPLC-MS/MS). METHODS: The drinking water was acidified with formic acid and concentrated by Bond Elut Plexa solid phase extraction column. The sample solution was separated using Waters ACQUITY HSS T3 column(100 mm×2.1 mm, 1.8 µm) with gradient elution using methanol-water containing 0.1% formic acid as mobile phase. The target compouds were detected in negtive electrospray ionization(ESI~-) and multiple reaction monitoring. RESULTS: The concentration of twelve HBQs showed good linearity in the range 5.0-150.0 ng/mL, respectively, with the correlation coefficients greater than 0.999. The limits of detection(LOD) of twelve HBQs were lower than 2.0 ng/mL, and the limits of quantification(LOQ) for twelve HBQs were lower than 5.0 ng/mL, respectively. The recoveries of three levels in the matrix were 70.0%-84.0%. The matrix effffect was 0.08-0.64. CONCLUSION: The SPE-UPLC-MS/MS method has high sensitivity, good accuracy and fast analysis speed for the detection of halobenzoquinones in drinking water.


Asunto(s)
Agua Potable , Formiatos , Espectrometría de Masas en Tándem , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos , Agua Potable/química , Cromatografía Líquida de Alta Presión/métodos , Extracción en Fase Sólida
19.
Environ Sci Pollut Res Int ; 31(20): 29460-29471, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38578593

RESUMEN

This work proposes the use of multi-criteria decision analysis (MCDA) to select a more environmentally friendly analytical procedure. TOPSIS, which stands for Technique for Order of Preference by Similarity to Ideal Solution, is an example of a MCDA method that may be used to rank or select best alternative based on various criteria. Thirteen analytical procedures were used in this study as TOPSIS input choices for mifepristone determination in water samples. The input data, which consisted of these choices, was described using assessment criteria based on 12 principles of green analytical chemistry (GAC). Based on the objective mean weighting (MW), the weights for each criterion were assigned equally. The most preferred analytical method according to the ranking was solid phase extraction with micellar electrokinetic chromatography (SPE-MEKC), while solid phase extraction combined with ultra-high performance liquid chromatography tandem mass spectrometry (SPE-UHPLC-MS/MS) was ranked last. TOPSIS ranking results were also compared to the green metrics NEMI, Eco-Scale, GAPI, AGREE, and AGREEprep that were used to assess the greenness of thirteen analytical methods for mifepristone determination. The results demonstrated that only the AGREE metric tool correlated with TOPSIS; however, there was no correlation with other metric tools. The analysis results suggest that TOPSIS is a very useful tool for ranking or selecting the analytical procedure in terms of its greenness and that it can be easily integrated with other green metrics tools for method greenness assessment.


Asunto(s)
Mifepristona , Contaminantes Químicos del Agua , Mifepristona/análisis , Contaminantes Químicos del Agua/análisis , Técnicas de Apoyo para la Decisión , Extracción en Fase Sólida , Cromatografía Líquida de Alta Presión , Espectrometría de Masas en Tándem
20.
Environ Sci Pollut Res Int ; 31(20): 30126-30136, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38602641

RESUMEN

Globally, per- and polyfluoroalkyl substances (PFAS)-related research on paper products has focused on food packaging with less consideration on the presence of PFAS at different stages of the paper recycling chain. This study analysed the prevalence of PFAS in paper grades used for the manufacture of recycled paperboard. The presence of PFAS was attributed to the use of PFAS-containing additives, consumer usage, exposure to packed goods as well as contamination during mingling, sorting, collection, and recovery of paper recycling material. Q Orbitrap mass spectrometry was used to analyse the paper samples after accelerated solvent extraction and solid phase extraction. The distribution and possible propagation of 22 PFAS were determined in pre-consumer, retail and post-consumer paper products. Post-consumer samples had the highest combined average concentration (ΣPFAS) at 213 ng/g, while the ΣPFAS in retail (159 ng/g) and pre-consumer samples (121 ng/g) was detected at lower concentrations. This study showed that waste collection and recycling protocols may influence PFAS propagation and that measures must be developed to minimise and possibly eliminate exposure opportunities.


Asunto(s)
Fluorocarburos , Espectrometría de Masas , Papel , Reciclaje , Fluorocarburos/análisis , Cromatografía Líquida de Alta Presión , Extracción en Fase Sólida
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA