Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.081
Filtrar
1.
Asian J Endosc Surg ; 17(3): e13348, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38965686

RESUMEN

Arterio-ureteral fistulas (AUFs), which are relatively rare but potentially life-threatening, require prompt diagnosis and treatment. We reported a case of AUFs following robot-assisted laparoscopic radical cystectomy (RARC) with extended pelvic lymph node dissection and ileal conduit urinary diversion for muscle-invasive bladder cancer, which resulted in massive hemorrhage. Urine leaked from the anastomosis between the ureter, and the end of the ileal conduit was infected, which resulted in an AUF between the pseudoaneurysm of the right common iliac artery and the ureter. The AUF was managed successfully by vascular intervention with an arterial stent graft.


Asunto(s)
Aneurisma Falso , Cistectomía , Arteria Ilíaca , Laparoscopía , Procedimientos Quirúrgicos Robotizados , Enfermedades Ureterales , Fístula Urinaria , Fístula Vascular , Humanos , Cistectomía/efectos adversos , Aneurisma Falso/etiología , Aneurisma Falso/cirugía , Fístula Urinaria/etiología , Fístula Urinaria/cirugía , Enfermedades Ureterales/etiología , Enfermedades Ureterales/cirugía , Arteria Ilíaca/cirugía , Fístula Vascular/etiología , Fístula Vascular/cirugía , Masculino , Complicaciones Posoperatorias/cirugía , Complicaciones Posoperatorias/etiología , Neoplasias de la Vejiga Urinaria/cirugía , Anciano , Persona de Mediana Edad
2.
J Med Case Rep ; 18(1): 285, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38902817

RESUMEN

BACKGROUND: An aortoesophageal fistula can prove to be fatal. Salvage thoracic endovascular aortic repair as a bridging therapy and radical surgery with thoracotomy should be considered while treating aortoesophageal fistula without spontaneous closure. Moreover, it is essential to select a technique that reduces the risk of reinfection. Here we report a rare case of a ruptured thoracic aortic aneurysm related to esophageal perforation by a fish bone that led to massive hematemesis and shock, and the surgical treatment of an aortoesophageal fistula that developed after salvage thoracic endovascular aortic repair. CASE PRESENTATION: A 70-year-old Japanese female patient was admitted with hematemesis, thoracic pain, and shock related to esophageal perforation of a ruptured descending aortic aneurysm caused by fish bone aspiration and esophageal perforation 1 month previously. An emergency thoracic endovascular aortic repair was performed. Postoperatively, an aortoesophageal fistula that remained open and a food intake-related increase in the inflammatory response was noted. Radical blood-vessel prosthesis implantation and fistula closure were performed. The patient's postoperative course was favorable and the patient was discharged 22 days after the blood vessel prosthesis implantation. CONCLUSION: Such a case of rupture of a descending aortic aneurysm related to perforation by a fish bone and an aortoesophageal fistula is considerably rare. Thus, we report the therapeutic strategy of this particular case and review the relevant literature.


Asunto(s)
Aneurisma de la Aorta Torácica , Rotura de la Aorta , Procedimientos Endovasculares , Fístula Esofágica , Perforación del Esófago , Humanos , Femenino , Fístula Esofágica/cirugía , Fístula Esofágica/etiología , Anciano , Procedimientos Endovasculares/métodos , Aneurisma de la Aorta Torácica/cirugía , Rotura de la Aorta/cirugía , Perforación del Esófago/cirugía , Perforación del Esófago/etiología , Fístula Vascular/cirugía , Fístula Vascular/etiología , Implantación de Prótesis Vascular , Terapia Recuperativa/métodos , Animales , Hematemesis/etiología , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/etiología , Aorta Torácica/cirugía , Resultado del Tratamiento , Peces , Reparación Endovascular de Aneurismas
3.
Artículo en Inglés | MEDLINE | ID: mdl-38695663

RESUMEN

A 72-year-old male with a history of a triple-vessel coronary artery bypass graft years ago presented with a DeBakey type 2 aortic dissection and an aorto-left atrial fistula with patent bypass grafts (left internal mammary artery and saphenous vein grafts). He developed pulmonary oedema and required intubation. The right axillary artery was cannulated. After the ascending aorta and left internal mammary artery were clamped, the aorta was transected, leaving aortic tissue around two saphenous vein grafts as two separate patches. An entry tear was found adjacent to the proximal anastomosis of the saphenous vein graft to the posterior descending artery. A fistula, which was located between a false lumen in the non-coronary sinus and the dome of the left atrium, was primarily closed. Because the adventitia was thinned out in the non-coronary sinus due to aortic dissection, partial aortic root remodelling was performed with resuspension of the commissures. Hemiarch repair was performed under moderate hypothermia and unilateral antegrade cerebral perfusion. After systemic perfusion was resumed, the locations of the saphenous vein graft buttons were determined. The ascending graft was cross-clamped again; the saphenous vein graft to the obtuse marginal branch graft was reimplanted using the Carrel patch technique while a saphenous vein graft to the posterior descending artery required interposition of a 10-mm Dacron graft to accommodate the length.


Asunto(s)
Disección Aórtica , Puente de Arteria Coronaria , Atrios Cardíacos , Humanos , Masculino , Anciano , Atrios Cardíacos/cirugía , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico , Puente de Arteria Coronaria/métodos , Puente de Arteria Coronaria/efectos adversos , Fístula Vascular/cirugía , Fístula Vascular/etiología , Fístula Vascular/diagnóstico , Fístula/cirugía , Fístula/etiología , Fístula/diagnóstico , Reoperación/métodos , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico , Vena Safena/trasplante
5.
J Cardiothorac Surg ; 19(1): 112, 2024 Mar 09.
Artículo en Inglés | MEDLINE | ID: mdl-38461352

RESUMEN

BACKGROUND: Aortoesophageal fistula (AEF) is a rare condition characterized by communication between the aorta and esophagus. AEF caused by an esophageal foreign body is even rare, and there is currently no recommended standard treatment protocol. We report a case of delayed aortic rupture after the endoscopic removal of a fish bone, which was successfully treated with a combined approach of vascular stenting and thoracic surgery. CASE PRESENTATION: A 33-year-old man presented to the hospital after experiencing chest discomfort for 3 days following the accidental ingestion of a fish bone. Under endoscopic guidance, the fish bone was successfully removed, and the patient was subsequently admitted for medical therapy. On the fourth postoperative day, the patient suddenly developed hematemesis, and chest computed tomography angiography revealed the presence of an AEF. This necessitated urgent intervention; hence, thoracic surgery was performed and a vascular-covered stent was placed. Following the surgical procedure, the patient received active medical treatment, recovered well, and was successfully discharged from the hospital. CONCLUSIONS: In patients with esophageal perforation caused by foreign bodies, hospitalization for observation, computed tomography angiography examination, early use of antibiotics, and careful assessment of aortic damage are advised. Thoracic endovascular aortic repair and esophageal rupture repair may have benefits for the treatment of AEF.


Asunto(s)
Enfermedades de la Aorta , Fístula Esofágica , Fístula Vascular , Masculino , Animales , Humanos , Adulto , Cirugía Torácica Asistida por Video/efectos adversos , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/complicaciones , Fístula Esofágica/cirugía , Fístula Esofágica/complicaciones , Hemorragia Gastrointestinal , Stents/efectos adversos , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía
6.
J Cardiovasc Electrophysiol ; 35(5): 1046-1049, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468182

RESUMEN

INTRODUCTION: Left atrial appendage (LAA) closure (LAAC) is considered a viable alternative to anticoagulation therapy for stroke prevention in nonvalvular atrial fibrillation, we report a case with a less common shunt resulting from a device-related coronary artery-appendage fistula (CAAF) following LAAC. METHODS AND RESULTS: A 67-year-old male with a history of LAAC was referred to our emergency room with recurrent chest pain and palpitations and was diagnosed with ischemic angina pectoris. Subsequent coronary angiography (CAG) revealed 70% in-stent restenosis and an abnormal shunt of contrast originating from the left circumflex artery (LCA) to the LAA tip which did not exist before. The restenosis was successfully dilated using a drug-coated balloon, the procedure was safely completed without pericardial effusion. The patient had been implanted with a LAmbre occluder (Lifetech Scientific Corp.) in the previous LAAC procedure. This occluder had a lobe-disk design, and the distal umbrella was not fully opened after release, particularly in the lower portion. This could make the hooks embedded on the umbrella contact the LAA wall more tightly, possibly resulting in microperforation and coincidental impingement of the LCA. The epicardial adipose and hyperplastic tissue then chronically wrapped the perforated site, prevented blood outflow into the epicardium, and ultimately formed a CAAF. CONCLUSION: CAAF is a rare complication after LAAC but may be underestimated, especially for lobe-disk designed occluders. Therefore, CAG is perhaps necessary to detect this complication.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Anciano , Humanos , Masculino , Apéndice Atrial/diagnóstico por imagen , Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/cirugía , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Vasos Coronarios/diagnóstico por imagen , Cierre del Apéndice Auricular Izquierdo , Diseño de Prótesis , Dispositivo Oclusor Septal/efectos adversos , Resultado del Tratamiento , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología
8.
J Vet Cardiol ; 52: 72-77, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38458041

RESUMEN

Aortocardiac fistula is a broad term used to describe defects between the aorta and other cardiac chambers that can occur in humans and animals. A 1.5-year-old, 1.7 kg, male castrated Holland lop rabbit (Oryctolagus cuniculus) was presented for a two-week history of a heart murmur with corresponding cardiomegaly on radiographs. Physical examination confirmed a grade-V/VI continuous heart murmur on the right sternal border with a regular rhythm and a gallop sound. Echocardiography revealed an aortic-to-right-atrial fistula causing severe left-sided volume overload. Based on the echocardiographic findings, rupture of the right aortic sinus was suspected. Due to the poor prognosis, euthanasia was elected. On necropsy, a fistula was found connecting the right aortic sinus with the right atrium, without evidence of an inflammatory response nor evidence of an infectious etiology. The sudden onset of a heart murmur supported acquired fistulation from a ruptured aortic sinus (also known as the sinus of Valsalva), though a congenital malformation could not be completely excluded.


Asunto(s)
Rotura de la Aorta , Seno Aórtico , Animales , Conejos , Masculino , Seno Aórtico/diagnóstico por imagen , Rotura de la Aorta/veterinaria , Rotura de la Aorta/diagnóstico por imagen , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Rotura Espontánea/veterinaria , Fístula/veterinaria , Fístula/diagnóstico por imagen , Fístula Vascular/veterinaria , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Ecocardiografía/veterinaria , Cardiopatías/veterinaria , Cardiopatías/diagnóstico por imagen , Soplos Cardíacos/veterinaria , Soplos Cardíacos/etiología
9.
J Cardiothorac Surg ; 19(1): 70, 2024 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-38326831

RESUMEN

BACKGROUND: Aortoesophageal fistula (AEF) is an extremely rare and highly fatal complication leading to a high risk of morbidity and mortality. Successful management of AEF after esophagectomy for esophageal carcinoma has rarely been reported in the literature. CASE PRESENTATION: Here we present a rare case of a 44-year-old female with complications of AEF after esophagectomy for esophageal carcinoma, mainly presented as vomiting of blood. Both computed tomographic and computed tomography angiography of the chest showed bilateral pleural effusion and atelectasis, while gastroscopy showed large gastrointestinal bleeding. Emergency surgery was performed that included the removal of the mediastinal abscess, left lower pulmonary wedge resection, and thoracic endovascular aortic repair (TEVAR), followed by supportive treatment. The surgery went successful, and the patient was followed up for 1 year after discharge and showed good recovery. We also reviewed previous literature on the history, causes, pathophysiology, clinical presentation, diagnosis, and treatment of AEF after esophagectomy for esophageal adenocarcinoma. CONCLUSIONS: In our case, thoracotomy combined with TEVAR was effective in treating AEF after esophagectomy for esophageal adenocarcinoma. This case provides successful experiences for clinical diagnosis and treatment of AEF after esophagectomy for esophageal carcinoma.


Asunto(s)
Adenocarcinoma , Enfermedades de la Aorta , Carcinoma , Fístula Esofágica , Fístula Vascular , Adulto , Femenino , Humanos , Adenocarcinoma/cirugía , Adenocarcinoma/complicaciones , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/complicaciones , Carcinoma/cirugía , Reparación Endovascular de Aneurismas , Fístula Esofágica/etiología , Fístula Esofágica/cirugía , Esofagectomía/efectos adversos , Hemorragia Gastrointestinal , Fístula Vascular/etiología , Fístula Vascular/cirugía
12.
Vasc Endovascular Surg ; 58(5): 554-558, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38166566

RESUMEN

Aortic graft and endograft infections remain a significant source of morbidity and mortality after abdominal aortic aneurysm repair. With graft excision and extra-anatomic bypass, an infrarenal aortic stump remains which can have suture line dehiscence and catastrophic stump blowout. Treatment of this is extremely challenging, especially for severely co-morbid patients who cannot undergo major surgery, or in patients with a hostile abdomen. We present a case study of a 74-year-old male found to have an aortoenteric fistula (AEF). This case broadens operative options for this type of patient population by demonstrating an endovascular technique for addressing aortic stump blowout by parallel grafting and coil embolization of the visceral aorta.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Fístula Intestinal , Fístula Vascular , Humanos , Masculino , Anciano , Embolización Terapéutica/instrumentación , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Procedimientos Endovasculares/instrumentación , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía , Fístula Vascular/terapia , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Fístula Intestinal/diagnóstico por imagen , Fístula Intestinal/etiología , Fístula Intestinal/cirugía , Fístula Intestinal/terapia , Aortografía , Angiografía por Tomografía Computarizada , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía
13.
Am Surg ; 90(6): 1648-1656, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38217444

RESUMEN

OBJECTIVE: Tracheoinnominate artery fistulas (TIFs) are a rare but deadly complication of tracheostomy. Tracheoinnominate artery fistula cases in the literature were summarized in order to understand mortality associations. METHODS: MEDLINE was searched for studies reporting individual characteristics of patients with TIFs after tracheostomy, excluding cases without tracheostomy or with additional procedures at the tracheostomy site. This study followed PRISMA guidelines. RESULTS: 121 TIF patients from 18 case series and 46 case reports were included. The median age was 40 years, and 52.9% were male. The overall mortality rate was 64.5%. There were differences in mortality between cases that presented initially with vs without sentinel bleeding (odds ratio [OR] .34; CI [confidence interval] .16-.73; P = .006). The mortality rate also differed in whether or not the tracheostomy cuff was over-inflated for temporary hemostasis during resuscitation (OR 3.57 (CI 1.57-8.09); P = .002). Treatment compared to no treatment had lower mortality rates (OR .11 (CI 0.04-.32); P < .001); no differences were found if treatment was endovascular vs open surgical. CONCLUSIONS: Mortality is a major concern after detection of a TIF and resuscitation paired with endovascular or open surgical intervention is imperative. Rapidly investigating sentinel bleeds and intervening upon hemorrhage with temporary cuff over inflation may lead to improved outcomes.


Asunto(s)
Traqueostomía , Fístula Vascular , Humanos , Masculino , Tronco Braquiocefálico/cirugía , Complicaciones Posoperatorias/mortalidad , Enfermedades de la Tráquea/etiología , Enfermedades de la Tráquea/mortalidad , Enfermedades de la Tráquea/cirugía , Traqueostomía/efectos adversos , Traqueostomía/métodos , Fístula Vascular/mortalidad , Fístula Vascular/etiología , Fístula Vascular/cirugía
14.
Vasc Endovascular Surg ; 58(2): 185-192, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37608725

RESUMEN

OBJECTIVES: Secondary aortoenteric fistula is a rare and life-threatening condition. Clear evidence on the ideal therapeutic approach is largely missing. This study aims to analyze symptoms, etiology, risk factors, and outcomes based on procedural details. PATIENTS AND METHODS: All patients with secondary aortoenteric fistula admitted between 2003 and 2021 were included. Patient characteristics, surgical procedure details, and postoperative outcomes were analyzed. Outcomes were stratified and compared according to the urgency of operation and the procedure performed. Descriptive statistics were used. The primary endpoint was in-hospital mortality. RESULTS: A total of twentytwo patients (68% male, median age 70 years) were identified. Main symptoms were gastrointestinal bleeding, pain, and fever. From the twentytwo patients ten patients required emergency surgery and ten urgent surgery. Emergency patients were older on average (74 vs 63 years, P = .015) and had a higher risk of postoperative respiratory complications (80% vs 10%, P = .005). Primary open surgery with direct replacement of the aorta or an extra-anatomic bypass with an additional direct suture or resection of the involved bowel was performed in sixteen patients. In four patients underwent endovascular bridging treatment with the definitive approach as a second step. Other two patients died without operation (1x refusal; 1x palliative cancer history). In-hospital mortality was 27%, respectively. Compared to patients undergoing urgent surgery, those treated emergently showed significantly higher in-hospital (50% vs 0%, P = .0033) mortalities. CONCLUSION: Despite rapid diagnosis and treatment, secondary aortoenteric fistula remains a life-threatening condition with 27% in-hospital mortality, significantly increased upon emergency presentation.


Asunto(s)
Enfermedades de la Aorta , Fístula Intestinal , Fístula Vascular , Humanos , Masculino , Anciano , Femenino , Resultado del Tratamiento , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/cirugía , Fístula Intestinal/diagnóstico por imagen , Fístula Intestinal/etiología , Fístula Intestinal/cirugía , Complicaciones Posoperatorias , Aorta , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía
16.
Ann Vasc Surg ; 101: 148-156, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38159719

RESUMEN

BACKGROUND: Information regarding optimal revascularization and digestive tract repair in secondary aortoenteric fistula (sAEF) remains unclear. Thus, reporting treatment outcomes and presenting comprehensive patient details through a structured treatment approach are necessary to establish a treatment strategy for this rare, complex, and fatal condition. METHODS: We performed a single-center retrospective review of consecutive sAEF managed based on our in situ revascularization and intestinal repair strategy. The primary endpoint of this study was all-cause mortality, and secondary endpoints were the incidence of in-hospital complications and midterm reinfections. RESULTS: Between 2007 and 2020, 16 patients with sAEF, including 13 men (81%), underwent in situ revascularization and digestive tract repair. The median follow-up duration for all participants was 36 (interquartile range, 6-62) months. Among the participants, 81% (n = 13), 13% (n = 2), and 6% (n = 1) underwent aortic reconstruction with rifampin-soaked grafts, unsoaked Dacron grafts, and femoral veins, respectively. The duodenum was the most commonly involved site in enteric pathology (88%; n = 14), and 57% (n = 8) of duodenal breaks were repaired by a simple closure. Duodenum's second part-jejunum anastomosis was performed in 43% of patients (n = 6), and 19% of the patients (n = 3) died perioperatively. In-hospital complications occurred in 88% patients (n = 14), and the most frequent complication was gastrointestinal. Finally, 81% patients (n = 13) were discharged home. Oral antibiotics were administered for a median duration of 5.7 months postoperatively; subsequently, the participants were followed up carefully. Reinfection was detected in 6% of the patients (n = 1) who underwent reoperation without any complications. The 1-year and 3-year overall survival rates of participants were 75% (n = 12) and 75% (n = 9), respectively, and no sAEF-related deaths occurred, except perioperative death. CONCLUSIONS: Surgical intervention with contemporary management based on our vascular strategy and digestive tract procedure may be a durable treatment for sAEF.


Asunto(s)
Enfermedades de la Aorta , Implantación de Prótesis Vascular , Fístula Intestinal , Fístula Vascular , Masculino , Humanos , Resultado del Tratamiento , Prótesis Vascular/efectos adversos , Fístula Intestinal/diagnóstico por imagen , Fístula Intestinal/etiología , Fístula Intestinal/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/complicaciones , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Estudios Retrospectivos , Duodeno/cirugía , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía
17.
J Cardiothorac Surg ; 18(1): 329, 2023 Nov 14.
Artículo en Inglés | MEDLINE | ID: mdl-37964318

RESUMEN

BACKGROUND: Aortoesophageal fistula (AEF) is a rare but typically life-threatening condition. Although several treatment strategies exist, including conservative treatment with intraluminal stent graft and open thoracic aortic replacement, the overall outcome remains poor, ranging from 16 to 39%. Furthermore, esophageal reconstruction methods vary between hospitals. Herein, we report a case of aortoesophageal fistula treated using one-stage total reconstruction. CASE PRESENTATION: This case involved a 58-year-old woman who developed acute type A aortic dissection and underwent successful total arch replacement at the other hospital. However, she developed AEF 1 year later and underwent urgent thoracic endovascular aortic repair, which eventually failed. We performed thoracic aortic replacement, total esophagectomy, gastric tube reconstruction, and omental flap in a one-stage operation. The patient was extubated the next day and transferred to the general ward on postoperative day 3. Computed tomography revealed favorable results. CONCLUSIONS: For postoperative AEF, dedicated debridement with reconstruction is more effective than conservative treatment. In an experienced center, post-procedure-related AEF can be easily treated using one-stage reconstruction.


Asunto(s)
Enfermedades de la Aorta , Implantación de Prótesis Vascular , Fístula Esofágica , Fístula Vascular , Femenino , Humanos , Persona de Mediana Edad , Implantación de Prótesis Vascular/efectos adversos , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía , Enfermedades de la Aorta/complicaciones , Fístula Esofágica/cirugía , Fístula Esofágica/complicaciones , Esofagectomía/métodos
19.
J Cardiothorac Surg ; 18(1): 243, 2023 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-37580735

RESUMEN

BACKGROUND: Aortobronchial fistula after TEVAR remains a vexing clinical problem associated with high mortality. Although a combination of endovascular and open surgical strategies have been reported in managing this pathology, there is as yet no definitive treatment algorithm that can be used for all patients. We discuss our approach to an aortobronchial fistula associated with an overtly infected aortic endograft. CASE PRESENTATION: A 49-year-old female sustained a traumatic aortic transection 14 years prior, managed by an endovascular stent-graft. Due to persistent endoleak, she underwent open replacement of her descending thoracic aorta 4 years later. Ten years after her open aortic surgery, the patient presented with hemoptysis, and a pseudoaneurysm at her distal aortic suture line was identified on computed tomography, whereupon she underwent placement of an endograft. Eight weeks later, she presented with dyspnea, recurrent hemoptysis, malaise and fever, with clinical and radiographic evidence of an aortobronchial communication and an infected aortic stent-graft. The patient underwent management via a two-stage open surgical approach, constituting an extra-anatomic bypass from her ascending aorta to distal descending aorta and subsequent radical excision of her descending aorta with all associated infected prosthetic material and repair of the airway. CONCLUSION: Aortobronchial fistula after TEVAR represents a challenging complex clinical scenario. Extra-anatomic aortic bypass followed by radical debridement of all contaminated tissue may provide the best option for durable longer-term outcomes.


Asunto(s)
Enfermedades de la Aorta , Implantación de Prótesis Vascular , Fístula Bronquial , Procedimientos Endovasculares , Fístula Vascular , Humanos , Femenino , Persona de Mediana Edad , Fístula Bronquial/etiología , Fístula Bronquial/cirugía , Aorta Torácica/cirugía , Reparación Endovascular de Aneurismas , Enfermedades de la Aorta/etiología , Enfermedades de la Aorta/cirugía , Hemoptisis/etiología , Hemoptisis/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/métodos , Stents/efectos adversos , Fístula Vascular/etiología , Fístula Vascular/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...