Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 216
Filtrar
1.
MMWR Morb Mortal Wkly Rep ; 73(26): 594-599, 2024 Jul 04.
Artículo en Inglés | MEDLINE | ID: mdl-38959171

RESUMEN

Xylazine has been increasingly detected in illegally manufactured fentanyl (IMF) products and overdose deaths in the United States; most xylazine-involved overdose deaths involve IMF. A convenience sample of U.S. adults aged ≥18 years was identified from those evaluated for substance use treatment during July 2022-September 2023. Data were collected using the Addiction Severity Index-Multimedia Version clinical assessment tool. Among 43,947 adults, 6,415 (14.6%) reported IMF or heroin as their primary lifetime substance-use problem; 5,344 (12.2%) reported recent (i.e., past-30-day) IMF or heroin use. Among adults reporting IMF or heroin as their primary lifetime substance-use problem, 817 (12.7%) reported ever using xylazine. Among adults reporting recent IMF or heroin use, 443 (8.3%) reported recent xylazine use. Among adults reporting IMF or heroin use recently or as their primary lifetime substance-use problem, those reporting xylazine use reported a median of two past nonfatal overdoses from any drug compared with a median of one overdose among those who did not report xylazine use; as well, higher percentages of persons who reported xylazine use reported other recent substance use and polysubstance use. Provision of nonjudgmental care and services, including naloxone, wound care, and linkage to and retention of persons in effective substance use treatment, might reduce harms including overdose among persons reporting xylazine use.


Asunto(s)
Consumidores de Drogas , Fentanilo , Centros de Tratamiento de Abuso de Sustancias , Xilazina , Adulto , Centros de Tratamiento de Abuso de Sustancias/estadística & datos numéricos , Fentanilo/química , Consumidores de Drogas/estadística & datos numéricos , Sobredosis de Droga/epidemiología , Sobredosis de Droga/prevención & control , Estudios Transversales , Dependencia de Heroína , Humanos , Masculino , Femenino , Estados Unidos/epidemiología
2.
J Mass Spectrom ; 59(8): e5070, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38989742

RESUMEN

Recently, our group has shown that fentanyl and many of its analogues form prototropic isomers ("protomers") during electrospray ionization. These different protomers can be resolved using ion mobility spectrometry and annotated using mobility-aligned tandem mass spectrometry fragmentation. However, their formation and the extent to which experimental variables contribute to their relative ratio remain poorly understood. In the present study, we systematically investigated the effects of mixtures of common chromatographic solvents (water, methanol, and acetonitrile) and pH on the ratio of previously observed protomers for 23 fentanyl analogues. Interestingly, these ratios (N-piperidine protonation vs. secondary amine/O = protonation) decreased significantly for many analogues (e.g., despropionyl ortho-, meta-, and para-methyl fentanyl), increased significantly for others (e.g., cis-isofentanyl), and remained relatively constant for the others as solvent conditions changed from 100% organic solvent (methanol or acetonitrile) to 100% water. Interestingly, pH also had significant effects on this ratio, causing the change in ratio to switch in many cases. Lastly, increasing conditions to pH ≥ 4.0 also prompted the appearance of new mobility peaks for ortho- and para-methyl acetyl fentanyl, where all previous studies had only showed one single distribution. Because these ratios have promise to be used qualitatively for identification of these (and emerging) fentanyl analogues, understanding how various conditions (i.e., mobile phase selection and/or chromatographic gradient) affect their ratios is critically important to the development of advanced ion mobility and mass spectrometry methodologies to identify fentanyl analogues.


Asunto(s)
Fentanilo , Espectrometría de Movilidad Iónica , Solventes , Fentanilo/análogos & derivados , Fentanilo/química , Fentanilo/análisis , Solventes/química , Espectrometría de Movilidad Iónica/métodos , Concentración de Iones de Hidrógeno , Espectrometría de Masa por Ionización de Electrospray/métodos , Isomerismo , Metanol/química , Acetonitrilos/química , Espectrometría de Masas en Tándem/métodos , Agua/química
3.
J Med Chem ; 67(12): 10447-10463, 2024 Jun 27.
Artículo en Inglés | MEDLINE | ID: mdl-38869493

RESUMEN

In recent years, synthetic opioids have emerged as a predominant cause of drug-overdose-related fatalities, causing the "opioid crisis." To design safer therapeutic agents, we accidentally discovered µ-opioid receptor (MOR) antagonists based on fentanyl with a relatively uncomplicated chemical composition that potentiates structural modifications. Here, we showed the development of novel atropisomeric fentanyl analogues that exhibit more potent antagonistic activity against MOR than naloxone, a morphinan MOR antagonist. Derivatives displaying stable axial chirality were synthesized based on the amide structure of fentanyl. The aS- and aR-enantiomers exerted antagonistic and agonistic effects on the MOR, respectively, and each atropisomer interacted with the MOR by assuming a distinct binding mode through molecular docking. These findings suggest that introducing atropisomerism into fentanyl may serve as a key feature in the molecular design of future MOR antagonists to help mitigate the opioid crisis.


Asunto(s)
Fentanilo , Receptores Opioides mu , Receptores Opioides mu/antagonistas & inhibidores , Receptores Opioides mu/metabolismo , Fentanilo/farmacología , Fentanilo/análogos & derivados , Fentanilo/química , Estereoisomerismo , Humanos , Simulación del Acoplamiento Molecular , Relación Estructura-Actividad , Animales , Antagonistas de Narcóticos/química , Antagonistas de Narcóticos/farmacología , Conformación Molecular , Analgésicos Opioides/farmacología , Analgésicos Opioides/química , Analgésicos Opioides/síntesis química , Células CHO , Cricetulus
4.
Anal Chim Acta ; 1312: 342686, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834256

RESUMEN

BACKGROUND: Fentanyl and its derivatives are a type of potent opioid analgesics, with the characteristics of diverse structure, high toxicity, extremely low content, and high fatality rate. Currently, they have become one of the most serious problems in international drug abuse control due to their extensive use in drug production and use. Therefore, the development of a rapid, sensitive, and accurate method for detecting trace fentanyl is of great significance. In this study, in view of its complex structure and trace concentration, a new molecular imprinting electrochemical sensor was developed through molecular simulations followed by experimental validation to detect trace fentanyl. RESULTS: The process consisted of first obtaining the optimal functional monomer and its molar ratio through molecular simulations. The recognition sites of fentanyl-imprinted polymers were predicted to guide the synthesis of imprinted membranes with precision approach to ensure an efficient and accurate reaction process. Reduced graphene oxide (ErGO) was then deposited on glassy carbon electrode surface by electrochemical reduction to yield large numbers of active sites suitable for catalyzing reactions of fentanyl piperidine for promoted efficient electron transfer and amplified sensitivity of the sensor. Accordingly, fentanyl molecularly imprinted film was formed through one-step electropolymerization to yield greatly improved sensing selectivity due to the specific recognition of molecularly imprinted polymer. Under optimal experimental conditions, the fentanyl sensor showed an extended detection range of 3.84 × 10-9 mol L-1-1.72 × 10-6 mol L-1 and a detection limit of 1.28 × 10-9 mol L-1. SIGNIFICANCE: A distinctive feature of this sensor is its molecularly imprinted polymerized membrane, which offers excellent specific recognition, thereby boosting the sensor's selectivity. Throughout the sensor's development process, molecular simulations were employed to steer the synthesis of molecularly imprinted polymers and predict the recognition sites of fentanyl-imprinted polymers. The experimental outcomes proved to align with the simulation data. The final sensor exhibited outstanding selectivity, repeatability, stability, and high sensitivity. The sensor was effectively used to reliably track fentanyl in human serum samples, with acceptable analytical reliability, suggesting its potential for practical applications.


Asunto(s)
Técnicas Electroquímicas , Fentanilo , Impresión Molecular , Fentanilo/análisis , Fentanilo/sangre , Fentanilo/química , Polímeros Impresos Molecularmente/química , Electrodos , Límite de Detección , Grafito/química , Simulación de Dinámica Molecular , Analgésicos Opioides/sangre , Analgésicos Opioides/análisis , Analgésicos Opioides/química , Humanos
5.
ACS Chem Neurosci ; 15(11): 2091-2098, 2024 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-38747710

RESUMEN

Xylazine (also known as "tranq") is a potent nonopioid veterinary sedative that has recently experienced a surge in use as a drug adulterant, most often combined with illicitly manufactured fentanyl. This combination may heighten the risk of fatal overdose. Xylazine has no known antidote approved for use in humans, and age-adjusted overdose deaths involving xylazine were 35 times higher in 2021 than 2018. In April 2023, the Biden Administration declared xylazine-laced fentanyl an emerging drug threat in the United States. In 2022, the Drug Enforcement Agency (DEA) reported nearly a quarter of seized fentanyl powder contained xylazine. This dramatic increase in prevalence has solidified the status of xylazine as an emerging drug of abuse and an evolving threat to public health. The following narrative review outlines the synthesis, pharmacokinetics, pharmacodynamics, and adverse effects of xylazine, as well as the role it may play in the ongoing opioid epidemic.


Asunto(s)
Xilazina , Xilazina/farmacología , Humanos , Animales , Hipnóticos y Sedantes/farmacología , Hipnóticos y Sedantes/química , Fentanilo/farmacología , Fentanilo/química , Analgésicos Opioides/química , Analgésicos Opioides/farmacología , Sobredosis de Droga/epidemiología
6.
J Med Chem ; 67(11): 9173-9193, 2024 06 13.
Artículo en Inglés | MEDLINE | ID: mdl-38810170

RESUMEN

While in the process of designing more effective synthetic opioid rescue agents, we serendipitously identified a new chemotype of potent synthetic opioid. Here, we report that conformational constraint of a piperazine ring converts a mu opioid receptor (MOR) antagonist into a potent MOR agonist. The prototype of the series, which we have termed atoxifent (2), possesses potent in vitro agonist activity. In mice, atoxifent displayed long-lasting antinociception that was reversible with naltrexone. Repeated dosing of atoxifent produced antinociceptive tolerance and a level of withdrawal like that of fentanyl. In rats, while atoxifent produced complete loss of locomotor activity like fentanyl, it failed to produce deep respiratory depression associated with fentanyl-induced lethality. Assessment of brain biodistribution demonstrated ample distribution of atoxifent into the brain with a Tmax of approximately 0.25 h. These results indicate enhanced safety for atoxifent-like molecules compared to fentanyl.


Asunto(s)
Analgésicos Opioides , Fentanilo , Receptores Opioides mu , Insuficiencia Respiratoria , Animales , Ratones , Receptores Opioides mu/agonistas , Receptores Opioides mu/metabolismo , Insuficiencia Respiratoria/inducido químicamente , Insuficiencia Respiratoria/tratamiento farmacológico , Analgésicos Opioides/farmacología , Analgésicos Opioides/síntesis química , Analgésicos Opioides/química , Ratas , Masculino , Fentanilo/farmacología , Fentanilo/síntesis química , Fentanilo/química , Relación Estructura-Actividad , Piperazinas/farmacología , Piperazinas/química , Piperazinas/síntesis química , Piperazinas/uso terapéutico , Piperazinas/farmacocinética , Humanos , Ratas Sprague-Dawley , Distribución Tisular , Encéfalo/metabolismo , Encéfalo/efectos de los fármacos , Naltrexona/farmacología , Naltrexona/análogos & derivados , Naltrexona/síntesis química , Naltrexona/química , Naltrexona/uso terapéutico
7.
J Am Soc Mass Spectrom ; 35(6): 1156-1167, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38709655

RESUMEN

Cannabinoids and opioids are the most prominently used drugs in the world, with fentanyl being the main cause of drug overdose-related deaths. Monitoring drug use in groups as well as in individuals is an important forensic concern. Analytical methods, such as mass spectrometry (MS), have been found most useful for the identification of drug abuse on a small and large scale. Pulsed fiber laser 2D galvoscanner laser-generated nanomaterial (PFL 2D GS LGN) was obtained from monoisotopic silver-109. Nanomaterial was used for laser desorption/ionization mass spectrometry of selected illicit drug standards with standard high-resolution reflectron-based time-of-flight MALDI apparatus. Δ9-THC, 11-OH-THC, 11-COOH-THC, fentanyl, codeine, 6-monoacetylmorphine (6-MAM), heroin, tramadol, and methadone were chosen as test compounds. Illicit drugs were tested in a concentration range from 100 µg/mL to 10 pg/mL, equating to 50 µg to 50 fg per measurement spot. For all analyzed compounds, identification and quantification by silver-109-assisted laser desorption/ionization (LDI) MS was possible, with uncommon [M + 109Ag3]+ and [M - H]+ ions present for certain structures. The results of the quantitative analysis of drugs using silver-109 PFL 2D GS LGN for LDI MS are presented. Laser-generated NPs are proven to be useful for the analysis of selected drugs, with exceptionally good results for fentanyl monitoring in a broad range of concentrations.


Asunto(s)
Drogas Ilícitas , Rayos Láser , Nanopartículas del Metal , Plata , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción , Detección de Abuso de Sustancias , Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción/métodos , Drogas Ilícitas/análisis , Drogas Ilícitas/química , Plata/química , Plata/análisis , Nanopartículas del Metal/química , Nanopartículas del Metal/análisis , Detección de Abuso de Sustancias/métodos , Humanos , Fentanilo/análisis , Fentanilo/análogos & derivados , Fentanilo/química , Derivados de la Morfina/análisis , Derivados de la Morfina/química , Cannabinoides/análisis , Cannabinoides/química
8.
ChemMedChem ; 18(23): e202300228, 2023 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-37817331

RESUMEN

Converting known ligands into photoswitchable derivatives offers the opportunity to modulate compound structure with light and hence, biological activity. In doing so, these probes provide unique control when evaluating G-protein-coupled receptor (GPCR) mechanism and function. Further conversion of such compounds into covalent probes, known as photoswitchable tethered ligands (PTLs), offers additional advantages. These include localization of the PTLs to the receptor binding pocket. Covalent localization increases local ligand concentration, improves site selectivity and may improve the biological differences between the respective isomers. This work describes chemical, photophysical and biochemical characterizations of a variety of PTLs designed to target the µ-opioid receptor (µOR). These PTLs were modeled on fentanyl, with the lead disulfide-containing agonist found to covalently interact with a cysteine-enriched mutant of this medically-relevant receptor.


Asunto(s)
Fentanilo , Receptores Opioides mu , Ligandos , Receptores Opioides mu/metabolismo , Fentanilo/química , Unión Proteica , Cisteína/metabolismo
9.
J Chem Inf Model ; 63(15): 4732-4748, 2023 08 14.
Artículo en Inglés | MEDLINE | ID: mdl-37498626

RESUMEN

The development of safe therapeutics to manage pain is of central interest for biomedical applications. The fluorinated fentanyl derivative N-(3-fluoro-1-phenethylpiperidin-4-yl)-N-phenylpropionamide (NFEPP) is potentially a safer alternative to fentanyl because unlike fentanyl─which binds to the µ-opioid receptor (MOR) at both physiological and acidic pH─NFEPP might bind to the MOR only at acidic pH typical of inflamed tissue. Knowledge of the protonation-coupled dynamics of the receptor-drug interactions is thus required to understand the molecular mechanism by which receptor activation initiates cell signaling to silence pain. To this end, here we have carried out extensive atomistic simulations of the MOR in different protonation states, in the absence of opioid drugs, and in the presence of fentanyl vs NFEPP. We used graph-based analyses to characterize internal hydrogen-bond networks that could contribute to the activation of the MOR. We find that fentanyl and NFEPP prefer distinct binding poses and that, in their binding poses, fentanyl and NFEPP partake in distinct internal hydrogen-bond networks, leading to the cytoplasmic G-protein-binding region. Moreover, the protonation state of functionally important aspartic and histidine side chains impacts hydrogen-bond networks that extend throughout the receptor, such that the ligand-bound MOR presents at its cytoplasmic G-protein-binding side, a hydrogen-bonding environment where dynamics depend on whether fentanyl or NFEPP is bound, and on the protonation state of specific MOR groups. The exquisite sensitivity of the internal protein-water hydrogen-bond network to the protonation state and to details of the drug binding could enable the MOR to elicit distinct pH- and opioid-dependent responses at its cytoplasmic G-protein-binding site.


Asunto(s)
Fentanilo , Receptores Opioides , Humanos , Fentanilo/farmacología , Fentanilo/química , Analgésicos Opioides/farmacología , Receptores Opioides mu/metabolismo , Dolor , Hidrógeno
10.
J Forensic Sci ; 68(5): 1527-1541, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37310093

RESUMEN

Definitive identification of fentanyl analogs based on mass spectral comparison is challenging given the high degree of structural and, hence, spectral similarity. To address this, a statistical method was previously developed in which two electron-ionization (EI) mass spectra are compared using the unequal variance t-test. Normalized intensities of corresponding ions are compared, testing the null hypothesis (H0 ) that the difference in intensity is equal to zero. If H0 is accepted at all m/z values, the two spectra are statistically equivalent at the specified confidence level. If H0 is not accepted at any m/z value, then there is a significant difference in intensity at that m/z value between the two spectra. In this work, the statistical comparison method is applied to distinguish EI spectra of valeryl fentanyl, isovaleryl fentanyl, and pivaloyl fentanyl. Spectra of the three analogs were collected over a 9-month period and at different concentrations. At the 99.9% confidence level, the spectra of corresponding isomers were statistically associated. Spectra of different isomers were statistically distinct, and ions responsible for discrimination were identified in each comparison. To account for inherent instrument variations, discriminating ions for each pairwise comparison were ranked based on the magnitude of the calculated t-statistic (tcalc ) value. For a given comparison, ions with higher tcalc values are those with the greatest difference in intensity between the two spectra and, therefore, are considered more reliable for discrimination. Using these methods, objective discrimination among the spectra was achieved and ions considered most reliable for discrimination of these isomers were identified.


Asunto(s)
Fentanilo , Fentanilo/análogos & derivados , Fentanilo/química , Espectrometría de Masas/métodos , Iones/química , Estructura Molecular
11.
Sci Rep ; 13(1): 2680, 2023 02 15.
Artículo en Inglés | MEDLINE | ID: mdl-36792632

RESUMEN

Cyclodextrins (CDs) have been previously shown to display modest equilibrium binding affinities (Ka ~ 100-200 M-1) for the synthetic opioid analgesic fentanyl. In this work, we describe the synthesis of new CDs possessing extended thioalkylcarboxyl or thioalkylhydroxyl moieties and assess their binding affinity towards fentanyl hydrochloride. The optimal CD studied displays a remarkable affinity for the opioid of Ka = 66,500 M-1, the largest value reported for such an inclusion complex to date. One dimensional 1H Nuclear Magnetic Resonance (NMR) as well as Rotational Frame Overhauser Spectroscopy (2D-ROESY) experiments supported by molecular dynamics (MD) simulations suggest an unexpected binding behavior, with fentanyl able to bind the CD interior in one of two distinct orientations. Binding energies derived from the MD simulations work correlate strongly with NMR-derived affinities highlighting its utility as a predictive tool for CD candidate optimization. The performance of these host molecules portends their utility as platforms for medical countermeasures for opioid exposure, as biosensors, and in other forensic science applications.


Asunto(s)
Ciclodextrinas , Ciclodextrinas/química , Fentanilo/química , Analgésicos Opioides , Espectroscopía de Resonancia Magnética/métodos , Simulación de Dinámica Molecular
12.
Nature ; 613(7945): 767-774, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36450356

RESUMEN

Mu-opioid receptor (µOR) agonists such as fentanyl have long been used for pain management, but are considered a major public health concern owing to their adverse side effects, including lethal overdose1. Here, in an effort to design safer therapeutic agents, we report an approach targeting a conserved sodium ion-binding site2 found in µOR3 and many other class A G-protein-coupled receptors with bitopic fentanyl derivatives that are functionalized via a linker with a positively charged guanidino group. Cryo-electron microscopy structures of the most potent bitopic ligands in complex with µOR highlight the key interactions between the guanidine of the ligands and the key Asp2.50 residue in the Na+ site. Two bitopics (C5 and C6 guano) maintain nanomolar potency and high efficacy at Gi subtypes and show strongly reduced arrestin recruitment-one (C6 guano) also shows the lowest Gz efficacy among the panel of µOR agonists, including partial and biased morphinan and fentanyl analogues. In mice, C6 guano displayed µOR-dependent antinociception with attenuated adverse effects, supporting the µOR sodium ion-binding site as a potential target for the design of safer analgesics. In general, our study suggests that bitopic ligands that engage the sodium ion-binding pocket in class A G-protein-coupled receptors can be designed to control their efficacy and functional selectivity profiles for Gi, Go and Gz subtypes and arrestins, thus modulating their in vivo pharmacology.


Asunto(s)
Diseño de Fármacos , Fentanilo , Morfinanos , Receptores Opioides mu , Animales , Ratones , Analgésicos Opioides/química , Analgésicos Opioides/metabolismo , Arrestinas/metabolismo , Microscopía por Crioelectrón , Fentanilo/análogos & derivados , Fentanilo/química , Fentanilo/metabolismo , Ligandos , Morfinanos/química , Morfinanos/metabolismo , Receptores Opioides mu/agonistas , Receptores Opioides mu/química , Receptores Opioides mu/metabolismo , Receptores Opioides mu/ultraestructura , Sitios de Unión , Nocicepción
13.
Pharmacol Biochem Behav ; 222: 173496, 2023 01.
Artículo en Inglés | MEDLINE | ID: mdl-36435268

RESUMEN

Synthetic narcotics have been implicated as the single greatest contributor to increases in opioid-related fatalities in recent years. This study evaluated the effects of nine fentanyl-related substances that have emerged in the recreational drug marketplace, and for which there are no existing or only limited in vivo data. Adult male Swiss Webster mice were administered fentanyl-related substances and their effects on locomotion as compared to MOR agonist standards were recorded. In locomotor activity tests, morphine (100, 180 mg/kg), buprenorphine (1, 10 mg/kg), fentanyl (1, 10 mg/kg), cyclopropylfentanyl (1, 10 mg/kg), cyclopentylfentanyl (10 mg/kg), (±)-cis-3-methylbutyrylfentanyl (0.1, 1, 10 mg/kg), ortho-methylacetylfentanyl (10 mg/kg), para-chloroisobutyrylfentanyl (100 mg/kg), ocfentanil (1, 10 mg/kg), and ortho-fluoroacrylfentanyl (0.1, 1, 10 mg/kg) elicited significant (p ≤ 0.05) dose-dependent increases in locomotion. However, 2,2,3,3-tetramethylcyclopropylfentanyl did not have any effects on locomotion, even when tested up to 100 mg/kg, and 4'-methylacetylfentanyl (10, 100 mg/kg) significantly decreased locomotion. The rank order of efficacy for stimulating locomotion (maximum effect as a % of fentanyl's maximum effect) for fentanyl-related substances relative to MOR agonist standards was cyclopropylfentanyl (108.84 ± 20.21) > fentanyl (100 ± 15.3) > ocfentanil (79.27 ± 16.92) > morphine (75.9 ± 14.5) > (±)-cis-3-methylbutyrylfentanyl (68.04 ± 10.08) > ortho-fluoroacrylfentanyl (63.56 ± 19.88) > cyclopentylfentanyl (56.46 ± 8.54) > para-chloroisobutyrylfentanyl (22.44 ± 8.51) > buprenorphine (11.26 ± 2.30) > ortho-methylacetylfentanyl (9.45 ± 2.92) > 2,2,3,3-tetramethylcyclopropylfentanyl (6.75 ± 1.43) > 4'-methylacetylfentanyl (3.47 ± 0.43). These findings extend in vivo results from previous reports documenting additional fentanyl related-related substances that stimulate locomotion similar to known abused opioids while also identifying some anomalies.


Asunto(s)
Analgésicos Opioides , Fentanilo , Animales , Masculino , Ratones , Analgésicos Opioides/farmacología , Buprenorfina , Fentanilo/química , Fentanilo/farmacología , Morfina/farmacología , Narcóticos/química , Narcóticos/farmacología
14.
PLoS One ; 17(11): e0275931, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36322521

RESUMEN

Electron Impact Gas Chromatography-Mass Spectrometry (EI-GC-MS) and High Resolution Liquid Chromatography-Mass Spectrometry (HR-LC-MS) have been used in the analysis of products arising from the trichloroethoxycarbonylation of fentanyl and acetylfentanyl in urine and plasma matrices. The method involves the initial extraction of both synthetic opioids separately from the matrices followed by detection of the unique products that arise from their reaction with 2,2,2-trichloroethoxycarbonyl chloride (Troc-Cl), namely Troc-norfentanyl and Troc-noracetylfentanyl. The optimized protocol was successfully evaluated for its efficacy at detecting these species formed from fentanyl and acetylfentanyl when present at low and high levels in urine (fentanyl: 5 and 10 ng/mL and acetylfentanyl: 20 and 100 ng/mL) and plasma (fentanyl: 10 and 20 ng/mL and acetylfentanyl: 50 and 200 ng/mL), values that reflect levels reported in overdose victims. The HR-LC-MS method's LOQ (limit of quantitation) for the Troc-norfentanyl and Troc-noracetylfentanyl products was determined to be ~10 ng/mL for both species. Even though the superiority in the detection of these species by HR-LC-MS over EI-GC-MS, the latter method proved to be important in the detection of the second product from the reaction, namely 2-phenylethyl chloride that is crucial in the determination of the original opioid. This observation highlights the importance of using complimentary analytical techniques in the analysis of a sample, whether biological or environmental in nature. The method herein serves as a complementary, qualitative confirmation for the presence of a fentanyl in collected urine, plasma and by extension other biological samples amenable to the common extraction procedures described for opioid analysis. More importantly, the method's main strength comes from its ability to react with unknown fentanyls to yield products that can be not only detected by EI-GC-MS and HR-LC-MS but can then be used to retrospectively identify an unknown fentanyl.


Asunto(s)
Analgésicos Opioides , Electrones , Cromatografía Liquida/métodos , Analgésicos Opioides/química , Cromatografía de Gases y Espectrometría de Masas , Estudios Retrospectivos , Cloruros , Espectrometría de Masas en Tándem/métodos , Fentanilo/química
15.
Brief Bioinform ; 23(6)2022 11 19.
Artículo en Inglés | MEDLINE | ID: mdl-36184256

RESUMEN

Fentanyl and its analogues are psychoactive substances and the concern of fentanyl abuse has been existed in decades. Because the structure of fentanyl is easy to be modified, criminals may synthesize new fentanyl analogues to avoid supervision. The drug supervision is based on the structure matching to the database and too few kinds of fentanyl analogues are included in the database, so it is necessary to find out more potential fentanyl analogues and expand the sample space of fentanyl analogues. In this study, we introduced two deep generative models (SeqGAN and MolGPT) to generate potential fentanyl analogues, and a total of 11 041 valid molecules were obtained. The results showed that not only can we generate molecules with similar property distribution of original data, but the generated molecules also contain potential fentanyl analogues that are not pretty similar to any of original data. Ten molecules based on the rules of fentanyl analogues were selected for NMR, MS and IR validation. The results indicated that these molecules are all unreported fentanyl analogues. Furthermore, this study is the first to apply the deep learning to the generation of fentanyl analogues, greatly expands the exploring space of fentanyl analogues and provides help for the supervision of fentanyl.


Asunto(s)
Aprendizaje Profundo , Fentanilo , Fentanilo/química , Analgésicos Opioides/química , Espectroscopía de Resonancia Magnética , Manejo de Datos
16.
Chemistry ; 28(63): e202201515, 2022 Nov 11.
Artículo en Inglés | MEDLINE | ID: mdl-35899620

RESUMEN

Photoswitchable ligands as biological tools provide an opportunity to explore the kinetics and dynamics of the clinically relevant µ-opioid receptor. These ligands can potentially activate or deactivate the receptor when desired by using light. Spatial and temporal control of biological activity allows for application in a diverse range of biological investigations. Photoswitchable ligands have been developed in this work, modelled on the known agonist fentanyl, with the aim of expanding the current "toolbox" of fentanyl photoswitchable ligands. In doing so, ligands have been developed that change geometry (isomerize) upon exposure to light, with varying photophysical and biochemical properties. This variation in properties could be valuable in further studying the functional significance of the µ-opioid receptor.


Asunto(s)
Fentanilo , Fentanilo/farmacología , Fentanilo/química , Ligandos
17.
Int J Mol Sci ; 23(5)2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35269909

RESUMEN

One of the strategies in the search for safe and effective analgesic drugs is the design of multitarget analgesics. Such compounds are intended to have high affinity and activity at more than one molecular target involved in pain modulation. In the present contribution we summarize the attempts in which fentanyl or its substructures were used as a µ-opioid receptor pharmacophoric fragment and a scaffold to which fragments related to non-opioid receptors were attached. The non-opioid 'second' targets included proteins as diverse as imidazoline I2 binding sites, CB1 cannabinoid receptor, NK1 tachykinin receptor, D2 dopamine receptor, cyclooxygenases, fatty acid amide hydrolase and monoacylglycerol lipase and σ1 receptor. Reviewing the individual attempts, we outline the chemistry, the obtained pharmacological properties and structure-activity relationships. Finally, we discuss the possible directions for future work.


Asunto(s)
Analgésicos Opioides , Fentanilo , Analgésicos/farmacología , Analgésicos Opioides/química , Fentanilo/química , Fentanilo/farmacología , Receptores de Droga , Receptores Opioides mu/metabolismo , Relación Estructura-Actividad
18.
J Am Soc Mass Spectrom ; 33(3): 482-490, 2022 Mar 02.
Artículo en Inglés | MEDLINE | ID: mdl-35041405

RESUMEN

Proton affinity is a major factor in the atmospheric pressure chemical ionization of illicit drugs. The detection of illicit drugs by mass spectrometry and ion mobility spectrometry relies on the analytes having greater proton affinities than background species. Evaluating proton affinities for fentanyl and its analogues is informative for predicting the likelihood of ionization in different environments and for optimizing the compounds' ionization and detection, such as through the addition of dopant chemicals. Herein, density functional theory was used to computationally determine the proton affinity and gas-phase basicity of 15 fentanyl compounds and several relevant molecules as a reference point. The range of proton affinities for the fentanyl compounds was from 1018 to 1078 kJ/mol. Fentanyl compounds with the higher proton affinity values appeared to form a bridge between the oxygen on the amide and the protonated nitrogen on the piperidine ring based on models and calculated bond distances. Experiments with fragmentation of proton-bound clusters using atmospheric flow tube-mass spectrometry (AFT-MS) provided estimates of relative proton affinities and showed proton affinity values of fentanyl compounds >1000 kJ/mol, which were consistent with the computational results. The high proton affinities of fentanyl compounds facilitate their detection by ambient ionization techniques in complex environments. The detection limits of the fentanyl compounds with AFT-MS are in the low femtogram range, which demonstrates the feasibility of trace vapor drug detection.


Asunto(s)
Fentanilo , Espectrometría de Masas/métodos , Presión Atmosférica , Fentanilo/análogos & derivados , Fentanilo/análisis , Fentanilo/química , Gases/análisis , Gases/química , Límite de Detección , Protones , Reproducibilidad de los Resultados , Detección de Abuso de Sustancias/métodos
19.
Biochem Pharmacol ; 195: 114805, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34673011

RESUMEN

Opioid-related fatalities involving synthetic opioids have reached unprecedented levels. This study evaluated the respiratory depressant effects of seven fentanyl analogs that have either emerged in the illicit drug supply or been identified in toxicological analyses following fatal or non-fatal intoxications. Adult male Swiss Webster mice were administered fentanyl analogs (isobutyrylfentanyl, crotonylfentanyl, para-methoxyfentanyl, para-methoxybutyrylfentanyl, 3-furanylfentanyl, thiophenefentanyl, and benzodioxolefentanyl) and their effects on minute volume as compared to mu-opioid receptor (MOR) agonist standards (fentanyl, morphine, and buprenorphine) were measured using whole body plethysmography (WBP). All drugs elicited significant (p ≤ 0.05) hypoventilation relative to vehicle for at least one dose tested: morphine (1, 3.2, 10, 32 mg/kg), buprenorphine, (0.032, 0.1, 0.32, 1, 3.2 mg/kg), fentanyl (0.0032, 0.01, 0.032, 0.1, 1, 32 mg/kg), isobutyrylfentanyl (0.1, 0.32, 1, 3.2, 10 mg/kg), crotonylfentanyl (0.1, 0.32, 1, 3.2, 10 mg/kg), para-methoxyfentanyl (0.1, 0.32, 1, 3.2, 10 mg/kg), para-methoxybutyrylfentanyl (0.32, 1, 3.2, 10 mg/kg), 3-furanylfentanyl (0.1, 0.32, 1, 3.2, 10 mg/kg), thiophenefentanyl (1, 3.2, 10, 32, 100 mg/kg), and benzodioxolefentanyl (3.2, 10, 32, 100 mg/kg). The ED50 values for hypoventilation showed a rank order of potency as follows: fentanyl (ED50 = 0.96 mg/kg) > 3-furanylfentanyl (ED50 = 2.60 mg/kg) > crotonylfentanyl (ED50 = 2.72 mg/kg) > para-methoxyfentanyl (ED50 = 3.31 mg/kg) > buprenorphine (ED50 = 10.8 mg/kg) > isobutyrylfentanyl (ED50 = 13.5 mg/kg) > para-methoxybutyrylfentanyl (ED50 = 16.1 mg/kg) > thiophenefentanyl (ED50 = 18.0 mg/kg) > morphine (ED50 = 55.3 mg/kg) > benzodioxolefentanyl (ED50 = 10,168 mg/kg). A naloxone pretreatment (10 mg/kg) attenuated the hypoventilatory effects of all drugs. These results establish that the respiratory depressant effects of these fentanyl analogs are at least in part mediated by the MOR.


Asunto(s)
Fentanilo/análogos & derivados , Hipoventilación/prevención & control , Naloxona/farmacología , Receptores Opioides mu/antagonistas & inhibidores , Animales , Fentanilo/química , Fentanilo/toxicidad , Hipoventilación/inducido químicamente , Hipoventilación/fisiopatología , Masculino , Ratones , Estructura Molecular , Antagonistas de Narcóticos/farmacología , Pletismografía/métodos , Receptores Opioides mu/fisiología , Mecánica Respiratoria/efectos de los fármacos , Mecánica Respiratoria/fisiología
20.
Crit Rev Anal Chem ; 52(8): 1938-1968, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-34053394

RESUMEN

The rising number of deaths caused by fentanyl overdosing in the US due to the overwhelming illicit use of this synthetic opioid has started a global campaign to develop efficient ways to control its production and distribution as well as discovering efficient antidotes to mitigate its lethal effects. Another important vein of focused research established by various agencies lies in the development of efficient and practical protocols for the detection of this opioid and analogs thereof in various matrices, whether environmental or biological in nature, particularly in the field of gas chromatography-mass spectrometry (GC-MS). The following review will cover the literature dealing with the detection and identification of synthetic opioids belonging to the fentanyl class by GC-MS means and hyphenated versions of the technique. Detailed descriptions will be given for the GC-MS methods employed for the analysis of the opioid, starting with the nature of the extraction protocol employed prior to analysis to the actual findings presented by the cited reports. Great effort has gone into describing the methods involved in each paper in a detailed manner and these have been compiled by year in tables at the end of each section for the reader's convenience. Lastly, the review will end with concluding remarks about the state of GC-MS analysis with regards to these powerful opioids and what lies ahead for this analytical field.


Asunto(s)
Analgésicos Opioides , Fentanilo , Fentanilo/análisis , Fentanilo/química , Analgésicos Opioides/análisis , Analgésicos Opioides/química , Cromatografía de Gases y Espectrometría de Masas , Cromatografía Liquida , Espectrometría de Masas en Tándem/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...