Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 315
Filtrar
1.
J Vet Intern Med ; 38(5): 2783-2789, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39212330

RESUMEN

Atrial fibrillation (AF) is a rarely reported arrhythmia in otherwise healthy newborn foals, with a single case of cardioversion using procainamide administration described in the literature. Two neonatal Thoroughbred colts were presented to an equine hospital because of an irregularly irregular tachyarrhythmia and poor latching when trying to nurse. History, physical examination, and initial diagnostic testing including ECG and echocardiography confirmed AF without structural heart disease. The 1st foal converted into normal sinus rhythm after treatment with IV metoprolol and quinidine. The 2nd foal converted to normal sinus rhythm after a single IV dose of metoprolol, intended for rate control. Demeanor and nursing behavior improved markedly after conversion. The 2 foals had normal heart rates and sinus rhythm that persisted for 6 weeks until euthanasia in the 1st foal and for 2 years in the 2nd foal. Rate control and cardioversion should be considered as a treatment for persistent lone AF in neonatal foals.


Asunto(s)
Animales Recién Nacidos , Antiarrítmicos , Fibrilación Atrial , Enfermedades de los Caballos , Metoprolol , Quinidina , Animales , Caballos , Enfermedades de los Caballos/tratamiento farmacológico , Antiarrítmicos/uso terapéutico , Antiarrítmicos/administración & dosificación , Quinidina/uso terapéutico , Quinidina/administración & dosificación , Fibrilación Atrial/veterinaria , Fibrilación Atrial/tratamiento farmacológico , Metoprolol/uso terapéutico , Metoprolol/administración & dosificación , Masculino , Femenino , Electrocardiografía/veterinaria , Administración Intravenosa/veterinaria
2.
J Vet Intern Med ; 38(4): 2076-2088, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38877661

RESUMEN

BACKGROUND: Rate control (RC; meanHRHolter ≤ 125 bpm) increases survival in dogs with atrial fibrillation (AF). The mechanisms remain unclear. HYPOTHESIS/OBJECTIVES: Investigate echocardiographic and biomarker differences between RC and non-RC (NRC) dogs. Determine if changes post-anti-arrhythmic drugs (AAD) predict successful RC in subsequent Holter monitoring. Evaluate if early vs late RC affects survival. ANIMALS: Fifty-two dogs with AF. METHODS: Holter-derived mean heart rate, echocardiographic and biomarker variables from dogs receiving AAD were analyzed prospectively at each re-evaluation and grouped into RC or NRC. The primary endpoint was successful RC. Between group comparisons of absolute values, magnitude of change from admission to re-evaluations and end of study were performed using Mann-Whitney tests or unpaired t-tests. Logistic regression explored variables associated with inability to achieve RC at subsequent visits. Kaplan-Meier survival analysis was used to compare survival time of early vs late RC. RESULTS: At visit 2, 11/52 dogs were RC; at visit 3, 14/52 were RC; and at visit 4, 4/52 were RC. At the end of study, 25/52 remained NRC. At visit 2, both groups had increased cardiac dimensions, but NRC dogs had larger dimensions; biomarkers did not differ. At the end of study, RC showed decreased cardiac dimensions and end-terminal pro-brain natriuretic peptide (NT-proBNP) compared with NRC. No variables were useful at predicting RC success in subsequent visits. Survival analysis found no differences between early vs late RC. CONCLUSIONS AND CLINICAL IMPORTANCE: The RC dogs had decreased cardiac dimensions and NT-proBNP, suggesting HR-mediated reverse-remodeling might benefit survival, even with delayed RC achievement. Pursuit of RC is crucial despite initial failures.


Asunto(s)
Fibrilación Atrial , Biomarcadores , Enfermedades de los Perros , Ecocardiografía , Péptido Natriurético Encefálico , Animales , Perros , Fibrilación Atrial/veterinaria , Enfermedades de los Perros/sangre , Enfermedades de los Perros/diagnóstico por imagen , Ecocardiografía/veterinaria , Biomarcadores/sangre , Masculino , Femenino , Péptido Natriurético Encefálico/sangre , Antiarrítmicos/uso terapéutico , Electrocardiografía Ambulatoria/veterinaria , Frecuencia Cardíaca , Estudios Longitudinales , Fragmentos de Péptidos/sangre , Estudios Prospectivos
3.
J Vet Cardiol ; 52: 19-27, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38402667

RESUMEN

Implantable loop recorders (ILRs) are increasingly used in equine cardiology to detect arrhythmias in the context of collapse, poor performance or monitoring for recurrence of atrial fibrillation (AF). However to date, the ILR has never been reported to be used with a remote monitoring functionality in horses, therefore the arrhythmia is only discovered when a clinician interrogates the ILR using dedicated equipment, which might delay diagnosis and intervention. This case report describes the use of an ILR with remote monitoring functionality in a horse with recurrent AF. The remote monitoring consisted of a transmission device located in the stable allowing daily transmission of arrhythmia recordings and functioning messages to an online server, available for the clinician to evaluate without specialised equipment. The ILR detected an episode of paroxysmal AF approximately three months after implantation. Seven months after implantation, initiation of persistent AF was seen on an episode misclassified by the ILR as bradycardia, and the horse was retired. This report shows the feasibility and benefits of remote monitoring for ILRs in horses, but also the shortcomings of current algorithms to interpret the equine electrocardiogram.


Asunto(s)
Fibrilación Atrial , Electrocardiografía Ambulatoria , Enfermedades de los Caballos , Caballos , Animales , Fibrilación Atrial/veterinaria , Fibrilación Atrial/diagnóstico , Enfermedades de los Caballos/diagnóstico , Electrocardiografía Ambulatoria/veterinaria , Electrocardiografía Ambulatoria/instrumentación , Masculino , Femenino
4.
Can Vet J ; 65(2): 115-118, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38304475

RESUMEN

The occurrence of right-sided congestive heart failure (CHF) in dogs with left-sided heart disease is well-recognized, but its mechanisms are incompletely understood. A 12-year-old Maltese dog was admitted to the clinic for left atrial decompression to treat recurrent CHF due to severe myxomatous mitral valve disease (MMVD). Left atrial decompression was successful but atrial fibrillation (AF) occurred during the procedure. Electric cardioversion restored normal sinus rhythm (NSR) and the dog's recovery was uneventful. This sequence of events made it possible to study intracameral pressures individually in each atrium in a dog with naturally occurring MMVD during AF and again during NSR. Although pressures in both atria declined following cardioversion, the right atrial pressure declined to a greater degree. These findings indicated a disproportionate effect of AF on right atrial pressure. This difference was noteworthy given the long-standing clinical observation that dogs with MMVD have a higher prevalence of right-sided CHF when AF is present. Key clinical message: A dog with MMVD had a greater reduction in right atrial pressure than in left atrial pressure when its AF was cardioverted as part of a cardiac catheterization procedure. This observation proposed a mechanism for the well-known but unexplained observation that dogs with MMVD manifest right-sided CHF disproportionately more often when they have AF.


Effets de la fibrillation auriculaire aiguë et de la cardioversion sur les pressions auriculaires gauche et droite chez un chien. La présence d'une insuffisance cardiaque congestive du côté droit (ICC) chez les chiens atteints d'une cardiopathie du côté gauche est bien connue, mais ses mécanismes ne sont pas complètement compris. Un chien maltais de 12 ans a été admis à la clinique pour une décompression auriculaire gauche afin de traiter une ICC récurrente due à une grave maladie myxomateuse de la valvule mitrale (MMVD). La décompression auriculaire gauche a réussi, mais une fibrillation auriculaire (FA) s'est produite pendant la procédure. La cardioversion électrique a rétabli le rythme sinusal normal (NSR) et la récupération du chien s'est déroulée sans incident. Cette séquence d'événements a permis d'étudier les pressions individuellement dans chaque oreillette chez un chien atteint de MMVD d'origine naturelle pendant la FA et à nouveau pendant la NSR. Bien que les pressions dans les deux oreillettes aient diminué après la cardioversion, la pression de l'oreillette droite a diminué dans une plus grande mesure. Ces résultats ont indiqué un effet disproportionné de la FA sur la pression auriculaire droite. Cette différence était remarquable compte tenu de l'observation clinique de longue date selon laquelle les chiens atteints de MMVD ont une prévalence plus élevée d'ICC du côté droit en cas de FA.Message clinique clé :Un chien atteint de MMVD présentait une réduction plus importante de la pression auriculaire droite que de la pression auriculaire gauche lorsque sa FA était cardiovertie dans le cadre d'une procédure de cathétérisme cardiaque. Cette observation propose un mécanisme pour l'observation bien connue mais inexpliquée selon laquelle les chiens atteints de MMVD manifestent une ICC du côté droit de manière disproportionnée plus souvent lorsqu'ils souffrent de FA.(Traduit par Dr Serge Messier).


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Insuficiencia Cardíaca , Enfermedades de las Válvulas Cardíacas , Perros , Animales , Fibrilación Atrial/veterinaria , Fibrilación Atrial/tratamiento farmacológico , Cardioversión Eléctrica/veterinaria , Presión Atrial , Enfermedades de las Válvulas Cardíacas/veterinaria , Atrios Cardíacos , Insuficiencia Cardíaca/veterinaria , Enfermedades de los Perros/cirugía
5.
J Vet Cardiol ; 52: 1-13, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38290222

RESUMEN

INTRODUCTION/OBJECTIVES: Spontaneous pulmonary vein (PV) activity triggers atrial fibrillation (AF) in humans. Although AF frequently occurs in horses, the origin remains unknown. This study investigated the structural and electro-anatomical properties of equine PVs to determine the potential presence of an arrhythmogenic substrate. ANIMALS, MATERIALS AND METHODS: Endocardial three-dimensional electro-anatomical mapping (EnSite Precision) using high-density (HD) catheters was performed in 13 sedated horses in sinus rhythm. Left atrium (LA) access was obtained retrogradely through the carotid artery. Post-mortem, tissue was harvested from the LA, right atrium (RA), and PVs for histological characterization and quantification of ion channel expression using immunohistochemical analysis. RESULTS: Geometry, activation maps, and voltage maps of the PVs were created and a median of four ostia were identified. Areas of reduced conduction were found at the veno-atrial junction. The mean myocardial sleeve length varied from 28 ± 13 to 49 ± 22 mm. The PV voltage was 1.2 ± 1.4 mV and lower than the LA (3.4 ± 0.9 mV, P < 0.001). The fibrosis percentage was higher in PV myocardium (26.1 ± 6.6%) than LA (14.5 ± 5.0%, P = 0.003). L-type calcium channel (CaV1.2) expression was higher in PVs than LA (P = 0.001). T-type calcium channels (CaV3.3), connexin-43, ryanodine receptor-2, and small conductance calcium-activated potassium channel-3 was expressed in PVs. CONCLUSIONS: The veno-atrial junction had lower voltages, increased structural heterogeneity and areas of slower conduction. Myocardial sleeves had variable lengths, and a different ion channel expression compared to the atria. Heterogeneous properties of the PVs interacting with the adjacent LA likely provide the milieu for re-entry and AF initiation.


Asunto(s)
Fibrilación Atrial , Venas Pulmonares , Animales , Caballos , Venas Pulmonares/patología , Fibrilación Atrial/veterinaria , Fibrilación Atrial/patología , Femenino , Masculino , Enfermedades de los Caballos/patología , Atrios Cardíacos/patología
6.
J Equine Vet Sci ; 133: 105001, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38190865

RESUMEN

In this case report, a high dose of torsemide (6mg/kg, every 12 hours for 3 days followed by 12mg/kg, every 12 hours for 4 days) was administered orally to a horse with congestive heart failure (CHF) and atrial fibrillation. Blood samples for measurement of plasma torsemide concentrations were obtained one hour after each drug administration. Pharmacodynamic effects of oral torsemide were evaluated by daily physical examination, electrocardiography, and serum biochemistry. The horse tolerated administration of torsemide. A decrease in ventral oedema and venous congestion was subjectively noted at day 7. Torsemide plasma concentration markedly increased at day 5 (peak concentration of 15.41 µg/mL). Evidence of an increase in renal markers was observed throughout the study period. Electrolyte measurements revealed mild hyponatremia and hypochloremia, and moderate hypokalaemia. No electrocardiographic changes related to torsemide administration were observed. After seven days of treatment, the horse was euthanised due to his disease stage and poor prognosis. Results indicate that torsemide was absorbed after oral administration and was well tolerated in this horse. Furthermore, clinical improvement in this single case indicates that torsemide might be utilized as an oral alternative to furosemide in the management of equine patients in CHF. The high doses of torsemide used in this case report should be reserved for cases without clinical response to lower doses and with close monitoring of electrolytes and renal function parameters. Further investigation of torsemide clinical efficacy and safety in horses with CHF with a larger cohort and prolonged administration is warranted.


Asunto(s)
Fibrilación Atrial , Insuficiencia Cardíaca , Enfermedades de los Caballos , Caballos , Animales , Torasemida/uso terapéutico , Sulfonamidas/uso terapéutico , Sulfonamidas/farmacología , Diuréticos/farmacología , Diuréticos/uso terapéutico , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/veterinaria , Insuficiencia Cardíaca/tratamiento farmacológico , Insuficiencia Cardíaca/veterinaria , Enfermedades de los Caballos/tratamiento farmacológico
7.
Vet J ; 303: 106043, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37992801

RESUMEN

Smartphone-based technology for electrocardiographic recording is now part of the new concept of mobile health in both human and veterinary medicine. Although smartphone-based ECG for electrocardiographic screening in dogs is reliable, one-lead ECG devices have mainly been evaluated. This prospective study assessed the feasibility and the diagnostic reliability of a new smartphone-based six-lead electrocardiograph (smECG) in dogs, in comparison to a standard six-lead electrocardiograph (stECG). All ECG tracings were blindly reviewed by an expert operator, who judged whether tracings were acceptable for interpretation, performed the electrocardiographic measurements, and assigned a diagnosis. The agreement in the electrocardiographic interpretation and diagnosis between smECG and stECG was assessed using the Bland-Altman test and Cohen's k test. The study included 108 client-owned dogs. The tracings obtained by the smECG were interpretable in 100 % of cases. No clinically relevant differences between smECG and stECG were found in the assessment of heart rate, interval duration, and QRS mean electrical axis. The smECG tended to underestimate the amplitude of the P and R waves. Perfect agreement was found in the detection of sinus rhythm, atrial fibrillation, ventricular arrhythmias, atrioventricular blocks, and bundle branch blocks. Our study suggests that the tested smartphone-based six-lead ECG is a clinically reliable device for the assessment of heart rate and heart rhythm in dogs, and thus could be used in a clinical setting in dogs and for telemedicine.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Humanos , Perros , Animales , Teléfono Inteligente , Estudios Prospectivos , Reproducibilidad de los Resultados , Electrocardiografía/veterinaria , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/veterinaria , Enfermedades de los Perros/diagnóstico
8.
Equine Vet J ; 56(3): 552-561, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-37654233

RESUMEN

BACKGROUND: Atrial fibrillation (AF) has been proposed as a risk factor for exercise-induced pulmonary haemorrhage (EIPH) due to increased pressure in the left atrium. OBJECTIVE: To evaluate if AF was associated with EIPH following a standardised exercise test (SET) to fatigue. STUDY DESIGN: Two-arm controlled experiment. METHODS: Ten untrained Standardbred mares mean (standard deviation [SD]) age 6 (2) years performed a SET on the treadmill in sinus rhythm (SR) (SET1) and 25-44 days after induction of self-sustained AF (SET2). AF was induced by tachypacing using a pacing device. Endoscopy, including tracheal wash and bronchoalveolar lavage (BAL), was performed 48-72 h before and 24 h after the two SETs. In addition, endoscopic grading of tracheal blood was performed 2 h after each SET. RESULTS: After SET1, none of the horses showed blood in the trachea, and two horses showed erythrophagocytosis. Following SET2, two horses had grade 1 blood in the trachea and free erythrocytes and erythrophagocytosis in the BAL, while another two horses had erythrophagocytosis in the BAL. In SET2, the overall performance on the treadmill was decreased with a lower maximum velocity (SET1 10.3 ± 0.8 m/s vs. SET2 8.9 ± 0.9 m/s, p = 0.004), a higher heart rate (284 ± 21 vs. 221 ± 18 bpm, p = 0.003) and more abnormal QRS complexes (p < 0.001) compared with SET1. CONCLUSIONS: Two horses showed signs of EIPH, resulting in visible blood in the trachea, when exercising in AF compared with SR. However, a possible link between EIPH, pulmonary pressure and AF needs to be further elucidated.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Caballos , Enfermedades Pulmonares , Condicionamiento Físico Animal , Animales , Caballos , Femenino , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/veterinaria , Prueba de Esfuerzo/veterinaria , Prueba de Esfuerzo/efectos adversos , Líquido del Lavado Bronquioalveolar , Enfermedades Pulmonares/etiología , Enfermedades Pulmonares/veterinaria , Hemorragia/etiología , Hemorragia/veterinaria , Condicionamiento Físico Animal/efectos adversos , Factores de Riesgo , Enfermedades de los Caballos/etiología
9.
Can Vet J ; 64(10): 951-956, 2023 10.
Artículo en Inglés | MEDLINE | ID: mdl-37780481

RESUMEN

Objective: To compare left atrial measurements carried out by an emergency and critical care (ECC) clinician on cats in lateral and sternal recumbency. Animals and procedures: A prospective observational study was conducted between December 2019 and January 2021 at the university teaching hospital at University of Liège. One hundred and two hospitalized cats were enrolled. Focused cardiac ultrasound (FOCUS) was performed in right lateral and sternal recumbency by a single FOCUS-trained ECC resident. Standard right parasternal long- and short-axis views were recorded. After randomization of the cineloops, the same blinded resident measured maximal left atrial dimension (LAD) and the ratio of left atrial to aortic diameter (LA:Ao). Reproducibility was assessed using the Bland-Altman method. Results: The LA:Ao and LAD measurements in lateral (LA:Ao median: 1.37, range: 1.02 to 3.22; LAD median: 13.25, range: 7.90 to 32.90) and sternal (LA:Ao median: 1.38, range: 1.06 to 3.22; LAD median: 13.00, range: 8.00 to 32.90) recumbency were not significantly different (bias: -0.003, CI -0.014, 0.007; and bias: -0.101, CI -0.231, 0.029, respectively). Conclusions and clinical relevance: The FOCUS technique was successfully applied in sternal recumbency in almost all cats. The LAD and LA:Ao measured in sternal and lateral recumbency were not significantly different. Cardiac left atrial measurements obtained using FOCUS can be reliably assessed in sternal recumbency in hospitalized, stable cats.


Mesure de l'oreillette gauche en décubitus latéral versus sternal chez les chats soumis à une échographie cardiaque focalisée. Objectif: Comparer les mesures de l'oreillette gauche effectuées par un clinicien des urgences et soins intensifs (ECC) sur des chats en décubitus latéral et sternal. Animaux et procédures: Une étude observationnelle prospective a été menée entre décembre 2019 et janvier 2021 au CHU de l'Université de Liège. Cent deux chats hospitalisés ont été enrôlés. L'échographie cardiaque focalisée (FOCUS) a été réalisée en décubitus latéral droit et sternal par un seul résident ECC formé au FOCUS. Des vues parasternales droites grand et petit axe standards ont été enregistrées. Après randomisation des cineloops, le même résident en aveugle a mesuré la dimension auriculaire gauche maximale (LAD) et le rapport entre le diamètre de l'oreillette gauche et celui de l'aorte (LA:Ao). La reproductibilité a été évaluée à l'aide de la méthode de Bland-Altman. Résultats: Les mesures LA:Ao et LAD en décubitus latéral (LA:Ao médian : 1,37, intervalle : 1,02 à 3,22; LAD médian : 13,25, intervalle : 7,90 à 32,90) et sternal (LA:Ao médian : 1,38, intervalle : 1,06 à 3,22; médiane LAD : 13,00, intervalle : 8,00 à 32,90) n'étaient pas significativement différents (biais : −0,003, IC −0,014, 0,007; et biais : −0,101, IC −0,231, 0,029, respectivement). Conclusions et pertinence clinique: La technique FOCUS a été appliquée avec succès en décubitus sternal chez presque tous les chats. Le LAD et LA:Ao mesurés en décubitus sternal et latéral n'étaient pas significativement différents. Les mesures de l'oreillette cardiaque gauche obtenues à l'aide de FOCUS peuvent être évaluées de manière fiable en décubitus sternal chez les chats hospitalisés et stables.(Traduit par Dr Serge Messier).


Asunto(s)
Fibrilación Atrial , Enfermedades de los Gatos , Humanos , Gatos , Animales , Fibrilación Atrial/veterinaria , Reproducibilidad de los Resultados , Ecocardiografía/veterinaria , Atrios Cardíacos/diagnóstico por imagen , Estudios Prospectivos , Enfermedades de los Gatos/diagnóstico por imagen
10.
J Vet Intern Med ; 37(6): 2021-2029, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37882250

RESUMEN

BACKGROUND: Differentiating cardiogenic vs noncardiogenic causes of respiratory signs can be challenging when echocardiography is unavailable. Radiographic vertebral left atrial size (VLAS) and vertebral heart size (VHS) have been shown to predict echocardiographic left heart size, with VLAS specifically estimating left atrial size. HYPOTHESIS/OBJECTIVES: Compare the diagnostic accuracy of VLAS and VHS to predict left-sided congestive heart failure (CHF) in dogs presenting with respiratory signs. ANIMALS: One-hundred fourteen dogs with respiratory signs and radiographic pulmonary abnormalities. METHODS: Retrospective cross-sectional study. Dogs had to have an echocardiogram and thoracic radiographs obtained within 24 hours. Diagnosis of CHF was confirmed based on the presence of respiratory signs, cardiac disease, LA enlargement, and cardiogenic pulmonary edema. RESULTS: Fifty-seven dogs had CHF and 57 did not have CHF. Compared to VHS (area under the curve [AUC] 0.85; 95% confidence interval [CI], 0.77-0.91), VLAS was a significantly (P = .03) more accurate predictor of CHF (AUC, 0.92; 95% CI, 0.85-0.96). Optimal cutoff for VLAS was >2.3 vertebrae (sensitivity, 93.0%; specificity, 82.5%). Murmur grade (P = .02) and VLAS (P < .0001) were independently associated with CHF and VHS was not. Increased VHS (54%) was significantly (P = .01) more common than increased VLAS (24%) in dogs without CHF. Results were similar in a subsample of older and smaller dogs. CONCLUSIONS AND CLINICAL IMPORTANCE: When echocardiography is unavailable, VLAS and murmur grade have clinically utility to aid in differentiating cardiogenic from noncardiogenic respiratory signs. These findings might be especially useful to help rule out CHF in dogs with increased VHS that present with respiratory signs.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Insuficiencia Cardíaca , Perros , Animales , Fibrilación Atrial/veterinaria , Estudios Transversales , Estudios Retrospectivos , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/veterinaria , Cardiomegalia/diagnóstico por imagen , Cardiomegalia/veterinaria , Columna Vertebral , Enfermedades de los Perros/diagnóstico por imagen
11.
J Vet Intern Med ; 37(6): 2573-2583, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37740606

RESUMEN

BACKGROUND: Atrial fibrillation (AF) is the most common performance limiting arrhythmia in racehorses. High dose exercise and airway disease promote AF in humans. Few studies have investigated epidemiological factors associated with AF in horses. OBJECTIVES: Explore variables relating to performance, exercise volume and postrace endoscopic findings in horses with AF. ANIMALS: A total of 164 horses with poor race performance and postrace AF were compared to 321 horses with poor performance without AF (PP) and 314 horses performing to expectation (TE). METHODS: Horse-level and race-level variables for horses racing in Australia and Hong Kong from 2009 to 2021 were compared using univariable and multivariable logistic regression. Postrace endoscopic exercise-induced pulmonary hemorrhage (EIPH) and tracheal mucus accumulation (TMA) grades for AF and PP horses were compared using chi-squared analysis. RESULTS: Variables that were significant in the multivariable model of AF compared to TE were distance (lengths) behind the winner, (odds ratio [OR]; 95% confidence interval [95% CI], 1.41 [1.32-1.51], P < .0001), cumulative prize money per start before the event (OR [95% CI] 1.02 [1.01-1.03], P = .01) and age (OR [95% CI] 0.72 [0.55-0.92], P = .01). More AF horses had EIPH grade ≥ 3 (23/109; 21.1%) than PP horses (7/213; 3.3%; OR [95%CI] 7.9 [3.3-20.2], P < .0001). CONCLUSIONS AND CLINICAL IMPORTANCE: Acute race performance was substantially impaired by AF but career earnings before the event were not inferior. Exercise volume did not promote AF. Higher grades of EIPH found in AF horses suggests a mechanistic relationship between these conditions.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Caballos , Enfermedades Pulmonares , Condicionamiento Físico Animal , Carrera , Humanos , Caballos , Animales , Fibrilación Atrial/etiología , Fibrilación Atrial/veterinaria , Condicionamiento Físico Animal/efectos adversos , Enfermedades de los Caballos/etiología , Enfermedades Pulmonares/veterinaria , Hemorragia/veterinaria
12.
J Vet Cardiol ; 49: 38-43, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37633187

RESUMEN

A 10-month-old female spayed Scottish Fold was referred to cardiology for incidental radiographic cardiomegaly. Echocardiography was suspicious for a right atrial or right auricular aneurysm. The differential diagnosis also included peritoneal-pericardial diaphragmatic hernia, mass lesion (cyst, granuloma, or neoplasia), or cardiac malformation. A giant right atrial aneurysm associated with a persistent left cranial vena cava was subsequently confirmed with computed tomography.


Asunto(s)
Aneurisma , Fibrilación Atrial , Enfermedades de los Gatos , Cardiopatías Congénitas , Femenino , Gatos , Animales , Fibrilación Atrial/veterinaria , Vena Cava Superior/diagnóstico por imagen , Vena Cava Superior/anomalías , Vena Cava Superior/patología , Aneurisma/complicaciones , Aneurisma/diagnóstico por imagen , Aneurisma/veterinaria , Cardiopatías Congénitas/diagnóstico , Cardiopatías Congénitas/veterinaria , Cardiomegalia/veterinaria , Enfermedades de los Gatos/diagnóstico por imagen
13.
J Zoo Wildl Med ; 54(2): 406-411, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37428707

RESUMEN

A 37-yr-old male vasectomized hybrid orangutan (Pongo pygmaeus × abelii) was diagnosed with left ventricular dysfunction during a preventative health care examination. Treatment was initiated with carvedilol. The following year, this orangutan was evaluated for intermittent lethargy. Following observation of an irregular cardiac rhythm during an echocardiogram, a lead II electrocardiogram revealed atrial fibrillation and ventricular arrhythmia. Additional treatment included amiodarone, furosemide, spironolactone, clopidogrel, and aspirin. An improved activity level was noted, and follow-up testing showed restoration of a sinus rhythm, reduced frequency of ventricular arrhythmia, and improved left ventricular function. The orangutan died 27 mon after initial diagnosis of heart disease, and a complete necropsy was performed. This article describes successful diagnosis and management of structural and arrhythmic heart disease in an orangutan, emphasizing the role of cardiac disease screening and behavioral training in apes, as well as the value of matching thorough antemortem and postmortem cardiac evaluation.


Asunto(s)
Fibrilación Atrial , Pongo abelii , Disfunción Ventricular Izquierda , Masculino , Animales , Pongo pygmaeus , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/terapia , Fibrilación Atrial/veterinaria , Fibrilación Ventricular/veterinaria , Pongo , Disfunción Ventricular Izquierda/veterinaria
14.
J Vet Cardiol ; 49: 1-8, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37517098

RESUMEN

A two-year and four-month, male German Shepherd was referred for exercise intolerance and panting. Irregular heart auscultation (250 beats per minute (bpm)) and pulse deficits were noted on physical exam. Electrocardiogram (ECG) showed irregular, narrow-QRS tachycardia without P waves compatible with coarse atrial fibrillation (AF). A 24-h ECG showed sustained AF (mean ventricular response rate 92 bpm). Echocardiography showed no structural abnormalities. Given the young age and presence of AF-related symptoms, rhythm control was preferred. Transthoracic electrical cardioversion was successfully performed six weeks later but AF recurred within 24-h. Sotalol was started but discontinued due to poor tolerance and AF persisted. Seven months after AF diagnosis, radiofrequency catheter ablation (RFCA) aiming for pulmonary vein isolation was performed under general anaesthesia. After transseptal puncture, three-dimensional electroanatomical mapping of the left atrium was performed. Point-by-point pulmonary vein isolation was achieved by RFCA. Seventy-eight RFCA lesions were placed in the left atrium encircling the three pulmonary vein ostia followed by electrical cardioversion. No complications occurred and the dog was discharged with amiodarone. In the immediate post-operative phase, there was recurrence of persistent AF requiring electrical cardioversion. Furthermore, at one month after the ablation, the dog experienced a single and transient paroxysm of AF. Since then, stable sinus rhythm (SR) was retained on daily ECG monitoring at home and confirmed by 24-h ECG three months post-operatively. Amiodarone was stopped subsequently. At the time of writing (one year post-operative), the dog remains in SR with normal exercise tolerance.


Asunto(s)
Amiodarona , Fibrilación Atrial , Ablación por Catéter , Enfermedades de los Perros , Venas Pulmonares , Masculino , Perros , Animales , Fibrilación Atrial/cirugía , Fibrilación Atrial/veterinaria , Resultado del Tratamiento , Venas Pulmonares/cirugía , Atrios Cardíacos , Ablación por Catéter/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/cirugía
15.
J Vet Cardiol ; 48: 54-62, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37480722

RESUMEN

INTRODUCTION/OBJECTIVES: Galectin-3 (Gal-3) is a circulating biomarker of fibrosis. In humans, increased Gal-3 is predictive of myocardial fibrosis and adverse cardiac events. The aim of this study was to evaluate the potential for Gal-3 as a cardiac biomarker in cats with hypertrophic cardiomyopathy (HCM). MATERIALS AND METHODS: Eighty cats were enrolled (25 healthy cats with normal hearts, 35 with HCM American College of Veterinary Internal Medicine (ACVIM) stage B, and 21 with HCM ACVIM stage C). Each cat received a full echocardiogram, health panel, and total thyroxin level. Galectin-3 levels were measured for each enrolled patient. Troponin I and N-terminal pro-brain natriuretic peptide (NT-proBNP) were obtained for the majority of cats. Additionally, 17 ACVIM stage B cats underwent cardiac-gated magnetic resonance (CMR) imaging to assess myocardial extracellular volume (ECV), a noninvasive measure of myocardial fibrosis. RESULTS: Galectin-3 levels are increased in cats with HCM ACVIM stage B and C compared to healthy cats; however, no significant differences were detected between ACVIM stage B and ACVIM stage C cats. In HCM-affected cats, Galectin-3 showed statistically significant correlations with left atrial dimensions, left atrial:aorta ratio, and CMR-derived ECV. Quantitative NT-proBNP showed excellent discrimination between all groups and troponin I was able to discriminate between ACVIM stage C and normal cats, but not between other groups. CONCLUSIONS: Circulating Gal-3 levels are increased in cats with HCM and is positively correlated with left atrial dimensions and ECV in affected cats. Further studies evaluating the relationship between Gal-3, myocardial fibrosis, and clinical outcomes are warranted.


Asunto(s)
Fibrilación Atrial , Cardiomiopatía Hipertrófica , Enfermedades de los Gatos , Humanos , Gatos , Animales , Galectina 3 , Fibrilación Atrial/veterinaria , Troponina I , Cardiomiopatía Hipertrófica/diagnóstico por imagen , Cardiomiopatía Hipertrófica/veterinaria , Biomarcadores , Fibrosis , Enfermedades de los Gatos/diagnóstico por imagen
16.
Vet Med Sci ; 9(5): 1973-1979, 2023 09.
Artículo en Inglés | MEDLINE | ID: mdl-37491011

RESUMEN

Three dogs were diagnosed with right atrial thrombosis, thought to be secondary to systemic diseases. Specifically, two cases had hyperadrenocorticism and one case was diagnosed with pancreatitis with acute renal injury. In all cases, the thrombi were found within the right atrium, necessitating a differentiation from cardiac neoplasia. In all three cases, the structures assumed to be thrombi had irregular margins with interspersed hypoechoic regions, which were later confirmed as thrombi based on the responsiveness to therapy. All three cases were prescribed with the combination of clopidogrel and rivaroxaban.The thrombi gradually disappeared after initiation of the combination therapy. Complete resolution of right atrial thrombosis was noted in each dog treated with clopidogrel and rivaroxaban. This combination therapy appears to be safe and well tolerated. Diligent observation of the echocardiographic findings and clinical course allows the diagnosis of thrombosis.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Cardiopatías , Trombosis , Perros , Animales , Fibrinolíticos/uso terapéutico , Fibrilación Atrial/complicaciones , Fibrilación Atrial/tratamiento farmacológico , Fibrilación Atrial/veterinaria , Rivaroxabán/uso terapéutico , Clopidogrel/uso terapéutico , Estudios de Seguimiento , Cardiopatías/diagnóstico por imagen , Cardiopatías/tratamiento farmacológico , Cardiopatías/veterinaria , Ecocardiografía/veterinaria , Atrios Cardíacos/diagnóstico por imagen , Trombosis/diagnóstico por imagen , Trombosis/tratamiento farmacológico , Trombosis/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/tratamiento farmacológico
17.
J Vet Intern Med ; 37(4): 1482-1487, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37382418

RESUMEN

Right atrial masses in dogs are commonly diagnosed as malignant tumors. This report describes a dog with a right atrial mass that appeared after successful electrical cardioversion of atrial fibrillation and resolved with antithrombotic treatment. A 9-year-old mastiff was presented for acute vomiting, and occasional cough of several weeks' duration. Ultrasonographic and radiographic examinations of the abdomen and chest identified mechanical ileus, as well as pleural effusion and pulmonary edema, respectively. Echocardiography indicated a dilated cardiomyopathy phenotype. During anesthetic induction for laparotomy, atrial fibrillation developed. Electrical cardioversion successfully restored sinus rhythm. An echocardiogram performed 2 weeks later disclosed a right atrial mass, which had not been apparent before cardioversion. Repeat echocardiography after 2 months of clopidogrel and enoxaparin treatment failed to detect the mass. Intra-atrial thrombus formation is possible after successful cardioversion of atrial fibrillation and should be considered as a differential diagnosis for echocardiographically detected atrial masses.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Cardiopatías , Trombosis , Perros , Animales , Fibrilación Atrial/terapia , Fibrilación Atrial/veterinaria , Cardioversión Eléctrica/veterinaria , Trombosis/etiología , Trombosis/terapia , Trombosis/veterinaria , Ecocardiografía/veterinaria , Cardiopatías/veterinaria , Ecocardiografía Transesofágica , Enfermedades de los Perros/diagnóstico por imagen , Enfermedades de los Perros/terapia
18.
J Vet Cardiol ; 47: 47-54, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37196397

RESUMEN

INTRODUCTION/OBJECTIVES: The aim of this study was to compare a novel small event recorder device, the Carnation Ambulatory Monitor (CAM), with a standard Holter. ANIMALS: Nineteen adult dogs. MATERIAL AND METHODS: Comparative and explorative study. The two devices were simultaneously applied for approximately 24 h. RESULTS: Analysis time (P=0.013) and percentage of artefacts (P<0.001) were greater for the CAM (110 min [40-264]; and 9% [0-34], respectively) compared to a standard Holter (30 min [18-270]; and 0.3% [0-9], respectively). The total number of beats (P=0.017) and maximum (P=0.02) and mean (P=0.037) heart rates were lower for the CAM (113,806 ± 23,619 beats; 227 ± 35 bpm; and 88 ± 22 bpm, respectively) compared to the standard Holter (131,640 ± 40,037 beats; 260 ± 64 bpm; and 92 ± 26 bpm, respectively). The minimal heart rate (P=0.725), number of pauses (P=0.078), duration of the longest pause (P=0.087), number of ventricular ectopic complexes (P=0.55), ventricular couplets (P=0.186), ventricular triplets (P=0.203), ventricular tachycardia (P=0.05), Lown grade (P=0.233), presence or absence of ventricular bigeminy, trigeminy, supraventricular tachycardia, and atrial fibrillation (P=0.98) did not differ. The CAM missed some relevant events, like complex ventricular arrhythmias, and the Lown grade did not match in 5/19 dogs when comparing the devices. CONCLUSIONS: Cardiac Ambulatory Monitor can be used to record ECG traces in dogs over a prolonged period, allowing to detect arrhythmias. Due to some clinically relevant limitations, including a higher percentage of artefacts, a longer reading time (which precludes quantitative counts of >300ventricular premature complexes), and underestimation of complex ventricular arrhythmias, the CAM appears not suitable for quantitative arrhythmia analysis in dogs.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Taquicardia Ventricular , Complejos Prematuros Ventriculares , Perros , Animales , Electrocardiografía Ambulatoria/veterinaria , Electrocardiografía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/veterinaria , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/veterinaria , Complejos Prematuros Ventriculares/diagnóstico , Complejos Prematuros Ventriculares/veterinaria , Enfermedades de los Perros/diagnóstico
19.
J Vet Intern Med ; 37(3): 887-899, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37128174

RESUMEN

BACKGROUND: The optimal heart rate (HR) in dogs with atrial fibrillation (AF) is unknown. Impact of HR on survival needs elucidation. HYPOTHESIS/OBJECTIVES: Dogs with a 24 hours Holter-derived meanHR ≤125 beats per minute (bpm; rate controlled) survive longer than dogs with higher meanHR. We further aimed to determine which variables predict ability to achieving rate control. ANIMALS: Sixty dogs with AF. METHODS: Holter-derived meanHR, clinical, echocardiographic, and biomarker variables were analyzed prospectively. Survival was recorded from time of rate control, with all-cause mortality as primary endpoint. Cox proportional hazards analysis identified variables independently associated with survival; Kaplan-Meier survival analysis estimated the median survival time of dogs with meanHR ≤125 bpm vs >125 bpm. Logistic regression explored baseline variables associated with inability to achieve rate control. RESULTS: Structural heart disease was present in 56/60 dogs, 50/60 had congestive heart failure, and 45/60 died. Median time to all-cause death was 160 days (range, 88-303 days), dogs with meanHR >125 bpm (n = 27) lived 33 days (95% confidence interval [CI], 15-141 days), dogs with meanHR ≤125 bpm (n = 33) lived 608 days (95% CI, 155-880 days; P < .0001). Congenital heart disease and N-terminal pro-B-type natriuretic peptide were independently associated with higher risk of death (P < .01 and <.0001, respectively) whereas meanHR ≤125 bpm decreased the risk of death (P < .001). Increased left atrial size, increased C-reactive protein concentration and lower blood pressure at admission were associated with failure to achieve rate control. CONCLUSIONS AND CLINICAL IMPORTANCE: Rate control affects survival; an optimal target meanHR <125 bpm should be sought in dogs with AF. Baseline patient variables can help predict if rate control is achievable.


Asunto(s)
Fibrilación Atrial , Enfermedades de los Perros , Insuficiencia Cardíaca , Perros , Animales , Fibrilación Atrial/veterinaria , Pronóstico , Frecuencia Cardíaca , Insuficiencia Cardíaca/complicaciones , Insuficiencia Cardíaca/veterinaria , Biomarcadores
20.
J Vet Cardiol ; 47: 19-29, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37141841

RESUMEN

OBJECTIVE: To propose echocardiographic left-atrial-to-aortic ratio (LA:Ao) limits for defining ordinal categories of left atrial (LA) enlargement in dogs. ANIMALS, MATERIALS AND METHODS: Right parasternal short-axis echocardiographic images from 33 dogs with various degrees of LA enlargement. Right parasternal short-axis and long-axis echocardiographic measurements from 238 healthy dogs. Images were duplicated and randomized. Duplicate images contained a LA:Ao estimate. Participants categorized the LA in each image into one of four categories: normal, mildly, moderately or severely enlarged. Distributions of categorization were compared between cardiologists and non-cardiologists. Intra-observer intra-study and inter-study agreement were examined. Effect of measurement was evaluated on agreement between participants. A parametric estimate of LA enlargement was calculated for both short-axis and long-axis views. RESULTS: Cardiologists and non-cardiologists provided similar distributions of LA size estimates, and showed similarly high intra-observer agreement (kappa = 0.84). Having a measurement provided with the image increased agreement for categorizing LA as normal or mildly enlarged (P<0.001). Parametric and consensus-based approaches provided similar limits for categorizing left atrial size in the right parasternal short-axis view - normal = LA:Ao < 1.6, mildly enlarged = 1.6 < LA:Ao < 1.9, moderately enlarged = 1.9 < LA:Ao < 2.3, severely enlarged = LA:Ao ≥ 2.3. A parametric approach for the right parasternal long-axis view provided the following: normal = LA:Ao < 2.1, mildly enlarged = 2.1 < LA:Ao < 2.5, moderately enlarged = 2.5 < LA:Ao < 2.7, severely enlarged = LA:Ao ≥ 2.7. CONCLUSIONS: Participants mostly classified LA sizes into four ordinal categories that corresponded to the aforementioned limits. Clinicians estimating LA size in early diastole can use these limits to increase inter-observer agreement when identifying LA enlargement.


Asunto(s)
Apéndice Atrial , Fibrilación Atrial , Enfermedades de los Perros , Animales , Perros , Aorta/diagnóstico por imagen , Fibrilación Atrial/veterinaria , Enfermedades de los Perros/diagnóstico por imagen , Ecocardiografía/veterinaria , Ecocardiografía/métodos , Atrios Cardíacos/diagnóstico por imagen
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...