Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.500
Filtrar
1.
Anal Chem ; 96(19): 7697-7705, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38697043

RESUMEN

Dual/multimodal imaging strategies are increasingly recognized for their potential to provide comprehensive diagnostic insights in cancer imaging by harnessing complementary data. This study presents an innovative probe that capitalizes on the synergistic benefits of afterglow luminescence and magnetic resonance imaging (MRI), effectively eliminating autofluorescence interference and delivering a superior signal-to-noise ratio. Additionally, it facilitates deep tissue penetration and enables noninvasive imaging. Despite the advantages, only a limited number of probes have demonstrated the capability to simultaneously enhance afterglow luminescence and achieve high-resolution MRI and afterglow imaging. Herein, we introduce a cutting-edge imaging platform based on semiconducting polymer nanoparticles (PFODBT) integrated with NaYF4@NaGdF4 (Y@Gd@PFO-SPNs), which can directly amplify afterglow luminescence and generate MRI and afterglow signals in tumor tissues. The proposed mechanism involves lanthanide nanoparticles producing singlet oxygen (1O2) upon white light irradiation, which subsequently oxidizes PFODBT, thereby intensifying afterglow luminescence. This innovative platform paves the way for the development of high signal-to-background ratio imaging modalities, promising noninvasive diagnostics for cancer.


Asunto(s)
Elementos de la Serie de los Lantanoides , Imagen por Resonancia Magnética , Nanopartículas , Polímeros , Semiconductores , Imagen por Resonancia Magnética/métodos , Animales , Elementos de la Serie de los Lantanoides/química , Polímeros/química , Nanopartículas/química , Ratones , Humanos , Gadolinio/química , Luminiscencia , Oxígeno Singlete/química , Itrio/química , Fluoruros/química , Ratones Desnudos
2.
Nat Commun ; 15(1): 3902, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724527

RESUMEN

Radiation-induced in situ tumor vaccination alone is very weak and insufficient to elicit robust antitumor immune responses. In this work, we address this issue by developing chiral vidarabine monophosphate-gadolinium nanowires (aAGd-NWs) through coordination-driven self-assembly. We elucidate the mechanism of aAGd-NW assembly and characterize their distinct features, which include a negative surface charge, ultrafine topography, and right-handed chirality. Additionally, aAGd-NWs not only enhance X-ray deposition but also inhibit DNA repair, thereby enhancing radiation-induced in situ vaccination. Consequently, the in situ vaccination induced by aAGd-NWs sensitizes radiation enhances CD8+ T-cell-dependent antitumor immunity and synergistically potentiates the efficacy immune checkpoint blockade therapies against both primary and metastatic tumors. The well-established aAGd-NWs exhibit exceptional therapeutic capacity and biocompatibility, offering a promising avenue for the development of radioimmunotherapy approaches.


Asunto(s)
Nanocables , Polímeros , Nanocables/química , Animales , Ratones , Polímeros/química , Línea Celular Tumoral , Gadolinio/química , Gadolinio/farmacología , Ratones Endogámicos C57BL , Linfocitos T CD8-positivos/inmunología , Linfocitos T CD8-positivos/efectos de los fármacos , Vacunas contra el Cáncer/inmunología , Femenino , Humanos , Vacunación/métodos , Neoplasias/inmunología
3.
Open Heart ; 11(1)2024 Apr 02.
Artículo en Inglés | MEDLINE | ID: mdl-38569668

RESUMEN

AIMS: Some patients with cardiac dystrophinopathy die suddenly. Whether such deaths are preventable by specific antiarrhythmic management or simply indicate heart failure overwhelming medical therapies is uncertain. The aim of this prospective, cohort study was to describe the occurrence and nature of cardiac arrhythmias recorded during prolonged continuous ECG rhythm surveillance in patients with established cardiac dystrophinopathy and relate them to abnormalities on cardiac MRI. METHODS AND RESULTS: A cohort of 10 patients (36.3 years; 3 female) with LVEF<40% due to Duchenne (3) or Becker muscular (4) dystrophy or Duchenne muscular dystrophy-gene carrying effects in females (3) were recruited, had cardiac MRI, ECG signal-averaging and ECG loop-recorder implants. All were on standard of care heart medications and none had prior history of arrhythmias.No deaths or brady arrhythmias occurred during median follow-up 30 months (range 13-35). Self-limiting episodes of asymptomatic tachyarrhythmia (range 1-29) were confirmed in 8 (80%) patients (ventricular only 2; ventricular and atrial 6). Higher ventricular arrhythmia burden correlated with extent of myocardial fibrosis (extracellular volume%, p=0.029; native T1, p=0.49; late gadolinium enhancement, p=0.49), but not with LVEF% (p=1.0) on MRI and atrial arrhythmias with left atrial dilatation. Features of VT episodes suggested various underlying arrhythmia mechanisms. CONCLUSIONS: The overall prevalence of arrhythmias was low. Even in such a small sample size, higher arrhythmia counts occurred in those with larger scar burden and greater ventricular volume, suggesting key roles for myocardial stretch as well as disease progression in arrhythmogenesis. These features overlap with the stage of left ventricular dysfunction when heart failure also becomes overt. The findings of this pilot study should help inform the design of a definitive study of specific antiarrhythmic management in dystrophinopathy. TRIAL REGISTRATION NUMBER: ISRCTN15622536.


Asunto(s)
Medios de Contraste , Insuficiencia Cardíaca , Humanos , Femenino , Estudios Prospectivos , Estudios de Cohortes , Proyectos Piloto , Gadolinio , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/etiología , Imagen por Resonancia Magnética , Antiarrítmicos/uso terapéutico , Insuficiencia Cardíaca/tratamiento farmacológico
4.
J Gastrointest Surg ; 28(4): 442-450, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38583894

RESUMEN

BACKGROUND: Vessels encapsulating tumor clusters (VETC) is a novel vascular pattern distinct from microvascular invasion that is significantly associated with poor prognosis in patients with hepatocellular carcinoma (HCC). This study aimed to predict the VETC pattern and prognosis of patients with HCC based on preoperative gadolinium-ethoxybenzyl-diethylenetriaminepentaacetic acid (Gd-EOB-DTPA) magnetic resonance imaging (MRI). METHODS: Patients with HCC who underwent surgical resection and preoperative Gd-EOB-DTPA MRI between January 1, 2016 and August 31, 2022 were retrospectively included. The variables associated with VETC were evaluated using logistic regression. A nomogram model was constructed on the basis of independent risk factors. COX regression was used to determine the variables associated with recurrence-free survival (RFS). RESULTS: A total of 98 patients with HCC were retrospectively included. Peritumoral hypointensity on the hepatobiliary phase (HBP) (odd ratio [OR], 2.58; 95% CI, 1.05-6.33; P = .04), tumor-to-liver signal intensity ratio on HBP of ≤0.75 (OR, 27.80; 95% CI, 1.53-502.91; P = .02), and tumor-to-liver apparent diffusion coefficient ratio of ≤1.23 (OR, 4.65; 95% CI, 1.01-21.38; P = .04) were independent predictors of VETC pattern. A nomogram was constructed by combining the aforementioned 3 significant variables. The accuracy, sensitivity, and specificity were 69.79%, 71.74%, and 68.00%, respectively, with an area under the receiver operating characteristic curve of 0.75 (95% CI, 0.65-0.83). The variables significantly associated with RFS of patients with HCC after surgery were Barcelona Clinic Liver Cancer stage (hazard ratio [HR], 2.15; 95% CI, 1.09-4.22; P = .03) and VETC pattern (HR, 2.28; 95% CI, 1.29-4.02; P = .004). CONCLUSION: The preoperative imaging features based on Gd-EOB-DTPA MRI can be used to predict the VETC pattern, which has prognostic significance for postoperative RFS of patients with HCC.


Asunto(s)
Carcinoma Hepatocelular , Neoplasias Hepáticas , Humanos , Carcinoma Hepatocelular/diagnóstico por imagen , Carcinoma Hepatocelular/cirugía , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Hepáticas/cirugía , Neoplasias Hepáticas/irrigación sanguínea , Gadolinio , Estudios Retrospectivos , Medios de Contraste , Gadolinio DTPA , Pronóstico , Imagen por Resonancia Magnética/métodos
5.
BMC Cardiovasc Disord ; 24(1): 203, 2024 Apr 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594610

RESUMEN

BACKGROUND: In patients with hypertrophic cardiomyopathy (HCM), ischemic myocardial fibrosis assessed by late gadolinium enhancement (I-LGE) using cardiovascular magnetic resonance (CMR) have been reported. However, the clinical significance of I-LGE has not been completely understood. We aim to evaluate the I-LGE differ phenotypically from HCM without LGE or nonischemic myocardial fibrosis assessed by late gadolinium enhancement (NI-LGE) in the left ventricle (LV). METHODS: The patients with HCM whom was underwent CMR were enrolled, using cine cardiac magnetic resonance to evaluate LV function and LGE to detect the myocardial fibrosis. Three groups were assorted: 1) HCM without LGE; 2) HCM with LGE involved the subendocardial layer was defined as I-LGE; 3) HCM with LGE not involved the subendocardial layer was defined as NI-LGE. RESULTS: We enrolled 122 patients with HCM in the present study. LGE was detected in 58 of 122 (48%) patients with HCM, and 22 (18%) of patients reported I-LGE. HCM with I-LGE had increased higher left ventricular mass index (LVMI) (P < 0.0001) than HCM with NI-LGE or without LGE. In addition, HCM with I-LGE had a larger LV end- systolic volume (P = 0.045), lower LV ejection fraction (LVEF) (P = 0.026), higher LV myocardial mass (P < 0.001) and thicker LV wall (P < 0.001) more than HCM without LGE alone. The I-LGE were significantly associated with LVEF (OR: 0.961; P = 0.016), LV mass (OR: 1.028; P < 0.001), and maximal end-diastolic LVWT (OR: 1.567; P < 0.001). On multivariate analysis, LVEF (OR: 0.948; P = 0.013) and maximal end-diastolic LVWT (OR: 1.548; P = 0.001) were associated with higher risk for I-LGE compared to HCM without LGE. Noticeably, the maximal end-diastolic LVWT (OR: 1.316; P = 0.011) was the only associated with NI-LGE compared to HCM without LGE. CONCLUSIONS: I-LGE is not uncommon in patients with HCM. HCM with I-LGE was associated with significant LV hypertrophy, extensive LGE and poor LV ejection fraction. We should consider focal ischemic myocardial fibrosis when applying LGE to risk stratification for HCM.


Asunto(s)
Cardiomiopatía Hipertrófica , Medios de Contraste , Humanos , Gadolinio , Imagen por Resonancia Cinemagnética , Cardiomiopatía Hipertrófica/diagnóstico , Miocardio/patología , Fibrosis , Espectroscopía de Resonancia Magnética
6.
Methodist Debakey Cardiovasc J ; 20(1): 23-25, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38618609

RESUMEN

A 51-year-old male with a complicated medical history presented with shortness of breath. Preoperative workup confirmed the presence of a large atrial mass. However, delayed gadolinium enhancement CMR with long inversion time (TI 600) showed lack of enhancement, which was suggestive of a thrombus. During cardiac magnetic resonance imaging, delayed gadolinium enhancement sequences with long inversion time (TI 600) are commonly used to distinguish between an avascular thrombus versus a vascular tumor.


Asunto(s)
Mixoma , Trombosis , Masculino , Humanos , Persona de Mediana Edad , Medios de Contraste , Gadolinio , Imagen por Resonancia Magnética , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/cirugía , Mixoma/complicaciones , Mixoma/diagnóstico por imagen , Mixoma/cirugía , Trombosis/diagnóstico por imagen , Trombosis/cirugía
7.
Clin Res Cardiol ; 113(5): 781-789, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38619578

RESUMEN

BACKGROUND: Cardiac magnetic resonance (CMR) provides information on morpho-functional abnormalities and myocardial tissue characterisation. Appropriate indications for CMR in athletes are uncertain. OBJECTIVE: To analyse the CMR performed at our Institute to evaluate variables associated with pathologic findings in a large cohort of athletes presenting with different clinical conditions. METHODS: All the CMR performed at our Institute in athletes aged > 14 years were recruited. CMR indications were investigated. CMR was categorised as "positive" or "negative" based on the presence of morphological and/or functional abnormalities and/or the presence of late gadolinium enhancement (excluding the right ventricular insertion point), fat infiltration, or oedema. Variables associated with "positive" CMR were explored. RESULTS: A total of 503 CMR were included in the analysis. "Negative" and "positive" CMR were 61% and 39%, respectively. Uncommon ventricular arrhythmias (VAs) were the most frequent indications for CMR, but the proportion of positive results was low (37%), and only polymorphic ventricular patterns were associated with positive CMR (p = 0.006). T-wave inversion at 12-lead ECG, particularly on lateral and inferolateral leads, was associated with positive CMR in 34% of athletes (p = 0.05). Echocardiography abnormalities resulted in a large proportion (58%) of positive CMR, mostly cardiomyopathies. CONCLUSION: CMR is more efficient in identifying a pathologic cardiac substrate in athletes in case of VAs (i.e., polymorphic beats), abnormal ECG repolarisation (negative T-waves in inferolateral leads), and borderline echocardiographic findings (LV hypertrophy, mildly depressed LV function). On the other hand, CMR is associated with a large proportion of negative results. Therefore, a careful clinical selection is needed to indicate CMR in athletes appropriately.


Asunto(s)
Cardiología , Cardiomiopatías , Humanos , Medios de Contraste , Gadolinio , Arritmias Cardíacas , Atletas , Espectroscopía de Resonancia Magnética , Imagen por Resonancia Cinemagnética/métodos , Valor Predictivo de las Pruebas
8.
Echocardiography ; 41(4): e15813, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38628060

RESUMEN

BACKGROUND: Mitral annular disjunction (MAD) is a structural abnormality characterized by the systolic detachment of the posterior mitral annulus and the ventricular myocardium. It is usually observed coexistent with mitral valve prolapse (MVP) and associated with a mechanical dysfunction despite preserved electrical isolation function of the mitral annulus. This study aimed to evaluate left ventricular (LV) function using speckle tracking echocardiography in MVP patients with MAD. METHODS: This study was designed as a prospective, single-center study including 103 patients with MVP and 40 age- and sex-matched control subjects. Transthoracic echocardiography and cardiac magnetic resonance imaging were performed to assess LV function and MAD presence. RESULTS: MAD (+) MVP (n = 34), MAD (-) MVP (n = 69), and control (n = 40) groups were enrolled in the study. Among the MVP patients, 34 (33%) had MAD. T-negativity in the inferior leads on electrocardiography was more frequent in the MAD (+) group than in the MAD (-) patients (4.3% vs. 20.6%, p = .014). Mitral regurgitation degree, Pickelhaube sign (17.6% vs. 1.4%, p = .005), and late gadolinium enhancement frequency (35.3% vs. 10.6%, p = .002) were significantly higher in MAD (+) patients. MAD (+) patients had significantly impaired global longitudinal strain (-23.1 ±  2.1 vs. -23.5 ± 2.3, p < .001), basal longitudinal strain (BLS) (-19.6 ±  1.5 vs. -20.5 ± 1.9, p < .001), Mid-Ventricular Longitudinal Strain (-22.2 ± 1.7 vs. -23.2 ± 2.2, p < .001) and LA strain (-24.5 ± 3.9 vs. -27.2 ± 3.6, p < .001) when compared to MAD (-) MVP patients, despite similar LV ejection fraction. All these values of MVP patients were also significantly lower than the control group. The mean MAD distance was 7.8 ± 3.2 mm in MAD (+) patients. Patients with two or more symptoms were higher in the MAD (+) group than in the MAD (-) group (4.3% vs. 44.1%, p < .001). CONCLUSION: This study demonstrated a significant decrease in longitudinal strain in MVP patients with MAD, indicating myocardial dysfunction. These findings suggest that MAD may contribute to LV dysfunction and highlight the importance of early detection in younger patients. Further research is needed to explore the functional implications and long-term outcomes of MAD.


Asunto(s)
Insuficiencia de la Válvula Mitral , Prolapso de la Válvula Mitral , Humanos , Función Ventricular Izquierda , Medios de Contraste , Estudios Prospectivos , Gadolinio , Válvula Mitral/diagnóstico por imagen , Prolapso de la Válvula Mitral/complicaciones , Prolapso de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/complicaciones , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Ecocardiografía/métodos
9.
Molecules ; 29(7)2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38611919

RESUMEN

The administration of magnetic resonance imaging (MRI) contrast agents (CAs) has been conducted since 1988 by clinicians to enhance the clarity and interpretability of MR images. CAs based on gadolinium chelates are the clinical standard used worldwide for the diagnosis of various pathologies, such as the detection of brain lesions, the visualization of blood vessels, and the assessment of soft tissue disorders. However, due to ongoing concerns associated with the safety of gadolinium-based contrast agents, considerable efforts have been directed towards developing contrast agents with better relaxivities, reduced toxicity, and eventually combined therapeutic modalities. In this context, grafting (or encapsulating) paramagnetic metals or chelates onto (within) carbon-based nanoparticles is a straightforward approach enabling the production of contrast agents with high relaxivities while providing extensive tuneability regarding the functionalization of the nanoparticles. Here, we provide an overview of the parameters defining the efficacy of lanthanide-based contrast agents and the subsequent developments in the field of nanoparticular-based contrast agents incorporating paramagnetic species.


Asunto(s)
Medios de Contraste , Nanoestructuras , Gadolinio , Carbono , Quelantes , Imagen por Resonancia Magnética
10.
Chemosphere ; 357: 142090, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38648983

RESUMEN

The growing utilization of rare earth elements (REEs) in industrial and technological applications has captured global interest, leading to the development of high-performance technologies in medical diagnosis, agriculture, and other electronic industries. This accelerated utilization has also raised human exposure levels, resulting in both favourable and unfavourable impacts. However, the effects of REEs are dependent on their concentration and molecular species. Therefore, scientific interest has increased in investigating the molecular interactions of REEs with biomolecules. In this current review, particular attention was paid to the molecular mechanism of interactions of Lanthanum (La), Cerium (Ce), and Gadolinium (Gd) with biomolecules, and the biological consequences were broadly interpreted. The review involved gathering and evaluating a vast scientific collection which primarily focused on the impact associated with REEs, ranging from earlier reports to recent discoveries, including studies in human and animal models. Thus, understanding the molecular interactions of each element with biomolecules will be highly beneficial in elucidating the consequences of REEs accumulation in the living organisms.


Asunto(s)
Lantano , Metales de Tierras Raras , Metales de Tierras Raras/química , Humanos , Lantano/química , Animales , Cerio/química , Gadolinio/química , Sustancias Macromoleculares/química
12.
Sci Data ; 11(1): 401, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38643183

RESUMEN

The current challenge in effectively treating atrial fibrillation (AF) stems from a limited understanding of the intricate structure of the human atria. The objective and quantitative interpretation of the right atrium (RA) in late gadolinium-enhanced magnetic resonance imaging (LGE-MRI) scans relies heavily on its precise segmentation. Leveraging the potential of artificial intelligence (AI) for RA segmentation presents a promising solution. However, the successful implementation of AI in this context necessitates access to a substantial volume of annotated LGE-MRI images for model training. In this paper, we present a comprehensive 3D cardiac dataset comprising 50 high-resolution LGE-MRI scans, each meticulously annotated at the pixel level. The annotation process underwent rigorous standardization through crowdsourcing among a panel of medical experts, ensuring the accuracy and consistency of the annotations. Our dataset represents a significant contribution to the field, providing a valuable resource for advancing RA segmentation methods.


Asunto(s)
Fibrilación Atrial , Atrios Cardíacos , Imagen por Resonancia Magnética , Humanos , Inteligencia Artificial , Fibrilación Atrial/patología , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Atrios Cardíacos/patología , Imagen por Resonancia Magnética/métodos
13.
Clin Imaging ; 109: 110140, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38574605

RESUMEN

PURPOSE: Gadolinium deposition has been reported in several normal anatomical structures in the brain after repeated administration of intravenous gadolinium-based contrast agents (GBCAs) used in magnetic resonance imaging (MRI). This study presents preliminary results to see if there is any gadolinium deposition in the dentate nucleus and globus pallidus after using intrathecal GBCAs. METHODS: Between November 2018 and November 2020, 29 patients who underwent intrathecal contrast-enhanced MR cisternography with the suspicion of rhinorrhea were included in this prospective study. In contrast-enhanced MR cisternography, gadoterate meglumine was administered by intrathecal injection at a dose of 1 ml. One month later, patients had a control MRI with 3D T1 SPACE fat-saturated (FS) and susceptibility weighted images (SWI) sequences. The ratio of dentate nucleus signal intensity to middle cerebellar peduncle signal intensity (DN/MCP ratio) and the ratio of globus pallidus signal intensity to thalamus signal intensity (GP/T ratio) were calculated using region of interest (ROI) on pre-contrast and control MRI sequences. RESULTS: There was no significant difference for DN/MCP ratio and GP/T ratio on 3D T1 SPACE FS and SWI sequences after intrathecal GBCAs administration compared to baseline MRI. CONCLUSION: Administration of intrathecal GBCAs did not cause a measurable change in the signal intensity of the dentate nucleus and globus pallidus after a single injection.


Asunto(s)
Medios de Contraste , Compuestos Organometálicos , Humanos , Gadolinio , Globo Pálido/diagnóstico por imagen , Globo Pálido/patología , Núcleos Cerebelosos/diagnóstico por imagen , Núcleos Cerebelosos/patología , Estudios Prospectivos , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Gadolinio DTPA
14.
Sci Rep ; 14(1): 9665, 2024 04 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671061

RESUMEN

This study clinically implemented a ready-to-use quantitative perfusion (QP) cardiovascular magnetic resonance (QP CMR) workflow, encompassing a simplified dual-bolus gadolinium-based contrast agent (GBCA) administration scheme and fully automated QP image post-processing. Twenty-five patients with suspected obstructive coronary artery disease (CAD) underwent both adenosine stress perfusion CMR and an invasive coronary angiography or coronary computed tomography angiography. The dual-bolus protocol consisted of a pre-bolus (0.0075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) and a main bolus (0.075 mmol/kg GBCA at 0.5 mmol/ml concentration + 20 ml saline) at an infusion rate of 3 ml/s. The arterial input function curves showed excellent quality. Stress MBF ≤ 1.84 ml/g/min accurately detected obstructive CAD (area under the curve 0.79; 95% Confidence Interval: 0.66 to 0.89). Combined visual assessment of color pixel QP maps and conventional perfusion images yielded a diagnostic accuracy of 84%, sensitivity of 70% and specificity of 93%. The proposed easy-to-use dual-bolus QP CMR workflow provides good image quality and holds promise for high accuracy in diagnosis of obstructive CAD. Implementation of this approach has the potential to serve as an alternative to current methods thus increasing the accessibility to offer high-quality QP CMR imaging by a wide range of CMR laboratories.


Asunto(s)
Medios de Contraste , Enfermedad de la Arteria Coronaria , Flujo de Trabajo , Humanos , Medios de Contraste/administración & dosificación , Femenino , Masculino , Persona de Mediana Edad , Anciano , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Angiografía Coronaria/métodos , Imagen de Perfusión Miocárdica/métodos , Gadolinio/administración & dosificación
15.
Molecules ; 29(8)2024 Apr 17.
Artículo en Inglés | MEDLINE | ID: mdl-38675647

RESUMEN

This study aimed to develop multifunctional nanoplatforms for both cancer imaging and therapy using superparamagnetic iron oxide nanoparticles (SPIONs). Two distinct synthetic methods, reduction-precipitation (MR/P) and co-precipitation at controlled pH (MpH), were explored, including the assessment of the coating's influence, namely dextran and gold, on their magnetic properties. These SPIONs were further functionalized with gadolinium to act as dual T1/T2 contrast agents for magnetic resonance imaging (MRI). Parameters such as size, stability, morphology, and magnetic behavior were evaluated by a detailed characterization analysis. To assess their efficacy in imaging and therapy, relaxivity and hyperthermia experiments were performed, respectively. The results revealed that both synthetic methods lead to SPIONs with similar average size, 9 nm. Mössbauer spectroscopy indicated that samples obtained from MR/P consist of approximately 11-13% of Fe present in magnetite, while samples obtained from MpH have higher contents of 33-45%. Despite coating and functionalization, all samples exhibited superparamagnetic behavior at room temperature. Hyperthermia experiments showed increased SAR values with higher magnetic field intensity and frequency. Moreover, the relaxivity studies suggested potential dual T1/T2 contrast agent capabilities for the coated SPpH-Dx-Au-Gd sample, thus demonstrating its potential in cancer diagnosis.


Asunto(s)
Medios de Contraste , Nanopartículas Magnéticas de Óxido de Hierro , Imagen por Resonancia Magnética , Nanopartículas de Magnetita , Nanomedicina Teranóstica , Nanopartículas Magnéticas de Óxido de Hierro/química , Imagen por Resonancia Magnética/métodos , Medios de Contraste/química , Nanopartículas de Magnetita/química , Nanopartículas de Magnetita/uso terapéutico , Humanos , Oro/química , Dextranos/química , Gadolinio/química , Propiedades de Superficie , Hipertermia Inducida/métodos , Tamaño de la Partícula
16.
Radiol Cardiothorac Imaging ; 6(2): e230172, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38573128

RESUMEN

Purpose To perform a qualitative and quantitative evaluation of the novel image-navigated (iNAV) 3D late gadolinium enhancement (LGE) cardiac MRI imaging strategy in comparison with the conventional diaphragm-navigated (dNAV) 3D LGE cardiac MRI strategy for the assessment of left atrial fibrosis in atrial fibrillation (AF). Materials and Methods In this prospective study conducted between April and September 2022, 26 consecutive participants with AF (mean age, 61 ± 11 years; 19 male) underwent both iNAV and dNAV 3D LGE cardiac MRI, with equivalent spatial resolution and timing in the cardiac cycle. Participants were randomized in the acquisition order of iNAV and dNAV. Both, iNAV-LGE and dNAV-LGE images were analyzed qualitatively using a 5-point Likert scale and quantitatively (percentage of atrial fibrosis using image intensity ratio threshold 1.2), including testing for overlap in atrial fibrosis areas by calculating Dice score. Results Acquisition time of iNAV was significantly lower compared with dNAV (4.9 ± 1.1 minutes versus 12 ± 4 minutes, P < .001, respectively). There was no evidence of a difference in image quality for all prespecified criteria between iNAV and dNAV, although dNAV was the preferred image strategy in two-thirds of cases (17/26, 65%). Quantitative assessment demonstrated that mean fibrosis scores were lower for iNAV compared with dNAV (12 ± 8% versus 20 ± 12%, P < .001). Spatial correspondence between the atrial fibrosis maps was modest (Dice similarity coefficient, 0.43 ± 0.15). Conclusion iNAV-LGE acquisition in individuals with AF was more than twice as fast as dNAV acquisition but resulted in a lower atrial fibrosis score. The differences between these two strategies might impact clinical interpretation. ©RSNA, 2024.


Asunto(s)
Fibrilación Atrial , Diafragma , Anciano , Humanos , Masculino , Persona de Mediana Edad , Fibrilación Atrial/diagnóstico , Medios de Contraste , Gadolinio , Atrios Cardíacos/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Prospectivos , Femenino
17.
Radiol Cardiothorac Imaging ; 6(2): e240020, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38602468

RESUMEN

Radiology: Cardiothoracic Imaging publishes novel research and technical developments in cardiac, thoracic, and vascular imaging. The journal published many innovative studies during 2023 and achieved an impact factor for the first time since its inaugural issue in 2019, with an impact factor of 7.0. The current review article, led by the Radiology: Cardiothoracic Imaging trainee editorial board, highlights the most impactful articles published in the journal between November 2022 and October 2023. The review encompasses various aspects of coronary CT, photon-counting detector CT, PET/MRI, cardiac MRI, congenital heart disease, vascular imaging, thoracic imaging, artificial intelligence, and health services research. Key highlights include the potential for photon-counting detector CT to reduce contrast media volumes, utility of combined PET/MRI in the evaluation of cardiac sarcoidosis, the prognostic value of left atrial late gadolinium enhancement at MRI in predicting incident atrial fibrillation, the utility of an artificial intelligence tool to optimize detection of incidental pulmonary embolism, and standardization of medical terminology for cardiac CT. Ongoing research and future directions include evaluation of novel PET tracers for assessment of myocardial fibrosis, deployment of AI tools in clinical cardiovascular imaging workflows, and growing awareness of the need to improve environmental sustainability in imaging. Keywords: Coronary CT, Photon-counting Detector CT, PET/MRI, Cardiac MRI, Congenital Heart Disease, Vascular Imaging, Thoracic Imaging, Artificial Intelligence, Health Services Research © RSNA, 2024.


Asunto(s)
Apéndice Atrial , Cardiopatías Congénitas , Radiología , Humanos , Medios de Contraste , Inteligencia Artificial , Gadolinio , Tomografía Computarizada por Rayos X
18.
Radiology ; 311(1): e240020, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38652027

RESUMEN

Gadolinium-based contrast agents (GBCAs) have augmented the capabilities of MRI, which has led to their widespread and increasing use in radiology practice. GBCAs are introduced into the environment through disposal of unused product and elimination after intravenous injection, both primarily via liquid dispersion into the environment. This human introduction of gadolinium into the environment, referred to as anthropogenic gadolinium, is associated with the detection of gadolinium in water systems, raising concerns for potential adverse impact and prompting certain mitigation actions. This article summarizes the existing knowledge and problem scope, conveys the relevant underlying chemical principles of chelate dissociation, and offers an inferred perspective that the magnitude of the problem is most unlikely to cause human harm. The merits and limitations regarding possible mitigation tactics, such as collecting urine after GBCA administration, use of lower-dose high-relaxivity macrocyclic GBCAs, and the option for virtual contrast-enhanced examinations, will be discussed. Finally, the potential for monitoring gadolinium uptake in bone will be presented, and recommendations for future research will be offered. © RSNA, 2024 See also the article by Ibrahim et al in this issue. See also the article by McKee et al in this issue.


Asunto(s)
Medios de Contraste , Gadolinio , Contaminación Química del Agua , Imagen por Resonancia Magnética
19.
Nanoscale ; 16(18): 9136, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38661520

RESUMEN

Expression of concern for 'Gadolinium embedded iron oxide nanoclusters as T1-T2 dual-modal MRI-visible vectors for safe and efficient siRNA delivery' by Xiaoyong Wang et al., Nanoscale, 2013, 5, 8098-8104, https://doi.org/10.1039/C3NR02797J.


Asunto(s)
Gadolinio , Imagen por Resonancia Magnética , ARN Interferente Pequeño , ARN Interferente Pequeño/química , ARN Interferente Pequeño/metabolismo , Gadolinio/química , Humanos , Compuestos Férricos/química , Medios de Contraste/química , Nanopartículas Magnéticas de Óxido de Hierro/química , Animales
20.
Int J Mol Sci ; 25(7)2024 Apr 06.
Artículo en Inglés | MEDLINE | ID: mdl-38612881

RESUMEN

Gadolinium-based contrast agents (GBCAs) have been used for more than 30 years to improve magnetic resonance imaging, a crucial tool for medical diagnosis and treatment monitoring across multiple clinical settings. Studies have shown that exposure to GBCAs is associated with gadolinium release and tissue deposition that may cause short- and long-term toxicity in several organs, including the kidney, the main excretion organ of most GBCAs. Considering the increasing prevalence of chronic kidney disease worldwide and that most of the complications following GBCA exposure are associated with renal dysfunction, the mechanisms underlying GBCA toxicity, especially renal toxicity, are particularly important. A better understanding of the gadolinium mechanisms of toxicity may contribute to clarify the safety and/or potential risks associated with the use of GBCAs. In this work, a review of the recent literature concerning gadolinium and GBCA mechanisms of toxicity was performed.


Asunto(s)
Líquidos Corporales , Medios de Contraste , Medios de Contraste/efectos adversos , Gadolinio/toxicidad , Riñón/diagnóstico por imagen , Imagen por Resonancia Magnética
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA