Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.553
Filtrar
1.
Biomed Phys Eng Express ; 10(5)2024 Jul 10.
Artículo en Inglés | MEDLINE | ID: mdl-38955138

RESUMEN

This work aims to improve the post stabilty of reusable potassium iodide hydrogel dosimter. A reusable and low-cost radiochromic dosimeter containing a gel matrix of polyvinyl alcohol, potassium iodide dye, froctose as reducing agent and glutaraldehyde as cross-linking agent was developed for dose calibration in radiotherapy. The gel samples were exposed to different absorbed doses using a medical linear acceleration. UV-vis Spectrophotometry was utilized to investigate the changes in optical-properties of irradiated gels with regard to peak wavelength of 353 nm. The stability of the gel (one of the most limitation of using this dosimeter) was improved significantly by the addition of certain concentrations of dimethyl sulfoxide. The two-dimensional optical imaging system of charge-coupled-device (CCD) camera with a uniform RGB light-emitting-diode (LED) array source was used for diffusion coefficient purpose using two dimensional gel template. The value of diffusion coefficient reported is significant and highly reduced compared with other dosimeters reported in the literatures. Moreover, heating the improved gels to certain temperatures results in resetting their optical properties, which makes it possible to reuse for multiple times.


Asunto(s)
Estudios de Factibilidad , Alcohol Polivinílico , Yoduro de Potasio , Dosímetros de Radiación , Alcohol Polivinílico/química , Yoduro de Potasio/química , Calibración , Geles/química , Humanos , Hidrogeles/química , Radiometría/métodos , Radiometría/instrumentación , Dimetilsulfóxido/química , Glutaral/química , Difusión , Temperatura
2.
J Med Case Rep ; 18(1): 314, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38978082

RESUMEN

BACKGROUND: The current study presents a novel and precise surgical technique for complete reconstruction of the aortic valve using glutaraldehyde-treated autologous pericardium in a patient with aortic valve disease and endocarditis. The technique aims to provide a more effective and reproducible method for aortic valve repair, with the goal of improving outcomes and quality of life for patients with aortic valve disease. CASE PRESENTATION: A 35-year-old Iranian male with aortic valve disease and endocarditis underwent aortic valve reconstruction surgery. Preoperative echocardiography showed a degenerative aortic valve with severe regurgitation, reduced left ventricular ejection fraction, and specific aortic root dimensions. The surgical technique involved precise measurements and calculations to design the size and shape of the new aortic valve cusps using autologous pericardium, with the goal of optimizing coaptation and function. The surgeon calculated the intercommissural distance based on the aortic annulus diameter to determine cusp size and shape. He tailored the pericardial cusps to have a height equal to 80% of the coaptation margin length. Detailed suturing techniques were used to ensure proper alignment and coaptation of the new cusps. Intraoperative evaluation of the valve function using suction and transesophageal echocardiography showed good coaptation and minimal residual regurgitation. At the 3-year follow-up, the patient had a well-functioning aortic valve with only trivial leak and was in satisfactory clinical condition. CONCLUSIONS: Glutaraldehyde-treated autologous pericardium is a validated leaflet alternative, and the causes of its failure are late annular dilatation and other technique breakdowns. Current evidence reveals that aortic valve reconstruction with glutaraldehyde-treated autologous pericardium is associated with many advantages with the potential to improve patient outcomes and quality of life. Further clinical studies are warranted to evaluate the long-term durability and efficacy of this approach.


Asunto(s)
Válvula Aórtica , Glutaral , Pericardio , Humanos , Masculino , Pericardio/trasplante , Adulto , Glutaral/uso terapéutico , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Trasplante Autólogo , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Procedimientos de Cirugía Plástica/métodos , Enfermedad de la Válvula Aórtica/cirugía , Resultado del Tratamiento , Ecocardiografía Transesofágica , Ecocardiografía , Endocarditis/cirugía
3.
Z Naturforsch C J Biosci ; 79(5-6): 149-153, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38869146

RESUMEN

Bio-electrochemical Systems (BES), particularly Microbial Fuel Cells (MFC), have emerged as promising technologies in environmental biotechnology. This study focused on optimizing the anode bacterial culture immobilization process to enhance BES performance. The investigation combines and modifies two key immobilization methods: covalent bonding with glutaraldehyde and inclusion in a chitosan gel in order to meet the criteria and requirements of the bio-anodes in MFC. The performance of MFCs with immobilized and suspended cultures was compared in parallel experiments. Both types showed similar substrate utilization dynamics with slight advantage of the immobilized bio-anode considering the lower concentration of biomass. The immobilized MFC exhibited higher power generation and metabolic activity, as well. Probably, this is due to improved anodic respiration and higher coulombic efficiency of the reactor. Analysis of organic acids content supported this conclusion showing significant inhibition of the fermentation products production in the MFC reactor with immobilized anode culture.


Asunto(s)
Fuentes de Energía Bioeléctrica , Células Inmovilizadas , Quitosano , Electrodos , Fuentes de Energía Bioeléctrica/microbiología , Células Inmovilizadas/metabolismo , Quitosano/metabolismo , Quitosano/química , Fermentación , Reactores Biológicos/microbiología , Biomasa , Glutaral/química , Electricidad
4.
Molecules ; 29(11)2024 Jun 06.
Artículo en Inglés | MEDLINE | ID: mdl-38893568

RESUMEN

We present the synthesis of a cross-linking enzyme aggregate (CLEAS) of a peroxidase from Megathyrsus maximus (Guinea Grass) (GGP). The biocatalyst was produced using 50%v/v ethanol and 0.88%w/v glutaraldehyde for 1 h under stirring. The immobilization yield was 93.74% and the specific activity was 36.75 U mg-1. The biocatalyst surpassed by 61% the free enzyme activity at the optimal pH value (pH 6 for both preparations), becoming this increase in activity almost 10-fold at pH 9. GGP-CLEAS exhibited a higher thermal stability (2-4 folds) and was more stable towards hydrogen peroxide than the free enzyme (2-3 folds). GGP-CLEAS removes over 80% of 0.05 mM indigo carmine at pH 5, in the presence of 0.55 mM H2O2 after 60 min of reaction, a much higher value than when using the free enzyme. The operational stability showed a decrease of enzyme activity (over 60% in 4 cycles), very likely related to suicide inhibition.


Asunto(s)
Enzimas Inmovilizadas , Peróxido de Hidrógeno , Carmin de Índigo , Peroxidasa , Carmin de Índigo/química , Peroxidasa/metabolismo , Peroxidasa/química , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Concentración de Iones de Hidrógeno , Peróxido de Hidrógeno/química , Estabilidad de Enzimas , Reactivos de Enlaces Cruzados/química , Temperatura , Glutaral/química
5.
Int J Biol Macromol ; 270(Pt 1): 132101, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38734354

RESUMEN

Aspergillus oryzae ß-D-galactosidase (ß-Gal) efficiently hydrolyzes sesaminol triglucoside into sesaminol, which has higher biological activity. However, ß-Gal is difficult to be separate from the reaction mixture and limited by stability. To resolve these problems, ß-Gal was immobilized on amino-functionalized magnetic nanoparticles mesoporous silica pre-activated with glutaraldehyde (Fe3O4@mSiO2-ß-Gal), which was used for the first time to prepare sesaminol. Under the optimal conditions, the immobilization yield and recovered activity of ß-Gal were 57.9 ± 0.3 % and 46.5 ± 0.9 %, and the enzymatic loading was 843 ± 21 Uenzyme/gsupport. The construction of Fe3O4@mSiO2-ß-Gal was confirmed by various characterization methods, and the results indicated it was suitable for heterogeneous enzyme-catalyzed reactions. Fe3O4@mSiO2-ß-Gal was readily separable under magnetic action and displayed improved activity in extreme pH and temperature conditions. After 45 days of storage at 4 °C, the activity of Fe3O4@mSiO2-ß-Gal remained at 92.3 ± 2.8 %, which was 1.29 times than that of free enzyme, and its activity remained above 85 % after 10 cycles. Fe3O4@mSiO2-ß-Gal displayed higher affinity and catalytic efficiency. The half-life was 1.41 longer than free enzymes at 55.0 °C. Fe3O4@mSiO2-ß-Gal was employed as a catalyst to prepare sesaminol, achieving a 96.7 % conversion yield of sesaminol. The excellent stability and catalytic efficiency provide broad benefits and potential for biocatalytic industry applications.


Asunto(s)
Aspergillus oryzae , Enzimas Inmovilizadas , Glutaral , Dióxido de Silicio , beta-Galactosidasa , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , beta-Galactosidasa/química , beta-Galactosidasa/metabolismo , Aspergillus oryzae/enzimología , Dióxido de Silicio/química , Glutaral/química , Dioxoles/química , Dioxoles/farmacología , Nanopartículas de Magnetita/química , Porosidad , Temperatura , Concentración de Iones de Hidrógeno , Estabilidad de Enzimas , Furanos
6.
Food Res Int ; 186: 114161, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38729685

RESUMEN

In this article, the synthesis of antioxidant peptides in the enzymatic hydrolysis of caprine casein was analyzed at three different time points (60 min, 90 min, and 120 min) using immobilized pepsin on activated and modified carbon (AC, ACF, ACG 50, ACG 100). The immobilization assays revealed a reduction in the biocatalysts' activity compared to the free enzyme. Among the modified ones, ACG 50 exhibited greater activity and better efficiency for reuse cycles, with superior values after 60 min and 90 min. Peptide synthesis was observed under all studied conditions. Analyses (DPPH, ß-carotene/linoleic acid, FRAP) confirmed the antioxidant potential of the peptides generated by the immobilized enzyme. However, the immobilized enzyme in ACG 50 and ACG 100, combined with longer hydrolysis times, allowed the formation of peptides with an antioxidant capacity greater than or equivalent to those generated by the free enzyme, despite reduced enzymatic activity.


Asunto(s)
Antioxidantes , Caseínas , Enzimas Inmovilizadas , Glutaral , Cabras , Iridoides , Pepsina A , Péptidos , Antioxidantes/química , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Caseínas/química , Animales , Pepsina A/metabolismo , Pepsina A/química , Glutaral/química , Péptidos/química , Iridoides/química , Hidrólisis , Carbón Orgánico/química
7.
J Pak Med Assoc ; 74(5): 843-847, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38783427

RESUMEN

OBJECTIVE: To compare the effect of propolis and gluma desensitisers on the management of dentin hypersensitivity. METHODS: The single-blind, randomised controlled trial was conducted at the Department of Operative Dentistry, Dr Ishrat ul Ebad Khan Institute of Oral Health Sciences, Dow University of Health Sciences, Karachi, from October 2020 to September 2021, and comprised patients with dentin hypersensitivity who had pain scores of at least 2 on the visual analogue scale. The teeth were randomised into propolis group A and Gluma group B. Baseline pain scores were assessed using visual analogue scale and Schiff's sensitivity scores and compared with scores immediately after the intervention, and then after one week and one month of the intervention. Data was analysed using SPSS 23. RESULTS: Of the 22 patients, 12(54.5%) were females and 10(45.4%) were males. Of the 80 teeth, there were 40(50%) in each of the 2 groups. Significant reduction was observed in dentin hypersensitivity immediately after the application of the desensitising agents (p<0.05). However, after one month, Gluma was more effective than propolis (p<0.05). CONCLUSIONS: Both Gluma and propolis were found to be effective desensitising agents, but the effectiveness of propolis decreased over one month. Clinical Trial Number: Clinical Trials.gov: NCT04819867.


Asunto(s)
Desensibilizantes Dentinarios , Sensibilidad de la Dentina , Própolis , Humanos , Própolis/uso terapéutico , Sensibilidad de la Dentina/tratamiento farmacológico , Femenino , Masculino , Adulto , Desensibilizantes Dentinarios/uso terapéutico , Método Simple Ciego , Metacrilatos/uso terapéutico , Dimensión del Dolor , Adulto Joven , Persona de Mediana Edad , Glutaral
8.
BMC Oral Health ; 24(1): 579, 2024 May 18.
Artículo en Inglés | MEDLINE | ID: mdl-38762747

RESUMEN

BACKGROUND: Vinyl polyether silicone (VPES) is a novel impression biomaterial made of a combination of vinyl polysiloxane (VPS) and polyether (PE). Thus, it is significant to assess its properties and behaviour under varied disinfectant test conditions. This study aimed to assess the dimensional stability of novel VPES impression material after immersion in standard disinfectants for different time intervals. METHODS: Elastomeric impression material used -medium body regular set (Monophase) [Exa'lence GC America]. A total of 84 Specimens were fabricated using stainless steel die and ring (ADA specification 19). These samples were distributed into a control group (n=12) and a test group (n=72). The test group was divided into 3 groups, based on the type of disinfectant used - Group-A- 2% Glutaraldehyde, Group-B- 0. 5% Sodium hypochlorite and Group-C- 2% Chlorhexidine each test group was further divided into 2 subgroups (n=12/subgroup) based on time intervals for which each sample was immersed in the disinfectants - subgroup-1- 10 mins and Subgroup 2- 30 mins. After the impression material was set, it was removed from the ring and then it was washed in water for 15 seconds. Control group measurements were made immediately on a stereomicroscope and other samples were immersed in the three disinfection solutions for 10 mins and 30 mins to check the dimensional stability by measuring the distance between the lines generated by the stainless steel die on the samples using a stereomicroscope at x40 magnification. RESULTS: The distance measured in the control group was 4397.2078 µm and 4396.1571 µm; for the test group Group-A- 2% Glutaraldehyde was 4396.4075 µm and 4394.5992 µm; Group-B- 0. 5% Sodium hypochlorite was 4394.5453 µm and 4389.4711 µm Group-C- 2% Chlorhexidine was 4395.2953 µm and 4387.1703 µm respectively for 10 mins and 30 mins. Percentage dimensional change was in the range of 0.02 - 0.25 for all the groups for 10 mins and 30 mins. CONCLUSIONS: 2 % Glutaraldehyde is the most suitable disinfectant for VPES elastomeric impression material in terms of dimensional stability and shows minimum dimensional changes as compared to that of 2% Chlorhexidine and 0.5% Sodium hypochlorite.


Asunto(s)
Materiales de Impresión Dental , Glutaral , Ensayo de Materiales , Polivinilos , Siloxanos , Materiales de Impresión Dental/química , Polivinilos/química , Siloxanos/química , Factores de Tiempo , Glutaral/química , Desinfectantes Dentales/química , Hipoclorito de Sodio/química , Desinfectantes/química , Clorhexidina/química , Propiedades de Superficie , Humanos
9.
BMC Oral Health ; 24(1): 458, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622548

RESUMEN

BACKGROUND: Various methods, chemical and physical, disinfect dental impressions. Common chemicals include 1% Sodium Hypochlorite and 2% glutaraldehyde, while UV radiation is a prevalent physical method. Few studies compare their effects on dimensional stability in polyether impressions. This study aims to assess such stability using different disinfection methods. Therefore, this study was planned to evaluate the dimensional stability of polyether impression material using different disinfection methods. METHODS: This in vitro study compared the effects of chemical disinfectants (1% Sodium Hypochlorite and 2% glutaraldehyde) and UV irradiation on the dimensional stability of polyether impression material. Groups A, B, C, and D, each with ten samples (N = 10), were studied. Group A was untreated (control). Group B was treated with 2% glutaraldehyde for 20 min, Group C with 1% Sodium Hypochlorite for 20 min, and Group D with UV rays for 20 min. A pilot milling machine drill was used to make four parallel holes labeled A, B, C, and D in the anterior and premolar regions from right to left. After sequential drilling, four implant analogs were positioned using a surveyor for accuracy. Ten open-tray polyether impressions were made and treated as described in the groups, followed by pouring the corresponding casts. Distortion values for each disinfection method were measured using a coordinate measuring machine capable of recording on the X- and Y-axes. RESULTS: A comprehensive analysis was conducted using the one-way ANOVA test for distinct groups labeled A, B, C, and D, revealing significant differences in the mean distances for X1, X2, X4, X5, and X6 among the groups, with p-values ranging from 0.001 to 0.000. However, no significant differences were observed in X3. Notably, mean distances for the Y variables exhibited substantial differences among the groups, emphasizing parameter variations, with p-values ranging from 0.000 to 0.033. The results compared the four groups using the one-way ANOVA test, revealing statistically significant distance differences for most X and Y variables, except for X3 and Y4. Similarly, post-hoc Tukey's tests provided specific pairwise comparisons, underlining the distinctions between group C and the others in the mean and deviation distances for various variables on both the X- and Y-axes. CONCLUSIONS: This study found that disinfection with 1% sodium hypochlorite or UV rays for 20 min maintained dimensional stability in polyether impressions.


Asunto(s)
Desinfectantes , Desinfección , Humanos , Desinfección/métodos , Glutaral , Hipoclorito de Sodio , Materiales de Impresión Dental , Técnica de Impresión Dental
10.
J Mater Sci Mater Med ; 35(1): 26, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38683259

RESUMEN

OBJECTIVE: Aortic valve neocuspidization (AVNeo) using autologous pericardium is a promising technique. Expected advantages are reduced immune response, appropriate biomechanics and lower treatment expenses. Nevertheless, autologous pericardium can be affected by patient's age and comorbidities. Usually, glutaraldehyde (GA) - fixed bovine pericardium is the basic material for aortic valve prostheses, easy available and carefully pre-examined in a standardized fabrication process. Aim of the study is the verification of autologous pericardial tissue homogeneity by analysing tissue thickness, biomechanics and extracellular matrix (ECM) composition. METHODS: Segments of human GA-fixed pericardium selected by the surgeon based on visual criteria for cusp pre-cut and remaining after surgical AV replacement were investigated in comparison to bovine standard tissue treated equivalently. Pericardium sampling was performed at up to three positions of each sutured cusp for histological or biomechanical analysis, according to tissue availability. RESULTS AND CONCLUSIONS: Human pericardia exhibited a higher heterogeneity in collagen content, density of vessel structures and elastic moduli. Thickness, vessel density and collagen and elastin content differed significantly between the species. In contrast, significant interindividual differences were detected in most properties investigated for human pericardial samples but only for tissue thickness in bovine tissues. Higher heterogeneity of human pericardium, differing vessel and collagen content compared to bovine state-of-the-art material might be detrimental for long term AV functionality or deterioration and have to be intensely investigated in patients follow up after autologous cusp replacement.


Asunto(s)
Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Pericardio , Bovinos , Humanos , Válvula Aórtica/cirugía , Animales , Fenómenos Biomecánicos , Masculino , Femenino , Anciano , Matriz Extracelular/química , Persona de Mediana Edad , Colágeno/química , Glutaral/química , Ensayo de Materiales , Implantación de Prótesis de Válvulas Cardíacas/métodos
11.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(2): 368-375, 2024 Apr 25.
Artículo en Chino | MEDLINE | ID: mdl-38686419

RESUMEN

The freeze-drying is a technology that preserves biological samples in a dry state, which is beneficial for storage, transportation, and cost saving. In this study, the bovine pericardium was treated with a freeze-drying protectant composed of polyethylene glycol (PEG) and trehalose (Tre), and then freeze-dried. The results demonstrated that the mechanical properties of the pericardium treated with PEG + 10% w/v Tre were superior to those of the pericardium fixed with glutaraldehyde (GA). The wet state water content of the rehydrated pericardium, determined using the Karl Fischer method, was (74.81 ± 1.44)%, which was comparable to that of the GA-fixed pericardium. The dry state water content was significantly reduced to (8.64 ± 1.52)%, indicating effective dehydration during the freeze-drying process. Differential scanning calorimetry (DSC) testing revealed that the thermal shrinkage temperature of the pericardium was (84.96 ± 0.49) ℃, higher than that of the GA-fixed pericardium (83.14 ± 0.11) ℃, indicating greater thermal stability. Fourier transform infrared spectroscopy (FTIR) results showed no damage to the protein structure during freeze-drying. Hematoxylin and eosin (HE) staining demonstrated that the freeze-drying process reduced pore formation, prevented ice crystal growth, and resulted in a tighter arrangement of tissue fibers. The frozen-dried bovine pericardium was subjected to tests for cell viability and hemolysis rate. The results revealed a cell proliferation rate of (77.87 ± 0.49)%, corresponding to a toxicity grade of 1. Additionally, the hemolysis rate was (0.17 ± 0.02)%, which is below the standard of 5%. These findings indicated that the frozen-dried bovine pericardium exhibited satisfactory performance in terms of cytotoxicity and hemolysis, thus meeting the relevant standards. In summary, the performance of the bovine pericardium treated with PEG + 10% w/v Tre and subjected to freeze-drying could meet the required standards.


Asunto(s)
Liofilización , Pericardio , Polietilenglicoles , Trehalosa , Animales , Pericardio/química , Trehalosa/química , Trehalosa/farmacología , Bovinos , Polietilenglicoles/química , Glutaral/química , Rastreo Diferencial de Calorimetría
12.
Food Chem ; 449: 139168, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38574521

RESUMEN

A robust biocompatible solid-phase microextraction (SPME) fiber, so-called Ti/APTS/GA/CS, was prepared by chemical bonding of cross-linked glutaraldehyde-chitosan to the surface of a titanium wire using APTS. The fiber was applied for sampling of phytohormones in plant tissues, followed by HPLC-UV analysis. The structure and morphology of the fiber coating was investigated by FT-IR, SEM, EDX, XRD, and TGA techniques. A Box-Behnken design was implemented to optimize the experimental variables. The calibration graphs were linear over a wide linear range (0.5-200 µg L-1) with LODs over the range of 0.01-0.06 µg L-1. The intra-day and inter-day precisions were found to be 1.3-6.3% and 4.3-7.3%, respectively. The matrix effect values ranged from 86.5% to 111.7%, indicating that the complex sample matrices had an insignificant effect on the determination of phytohormones. The fiber was successfully employed for the direct-immersion SPME (DI-SPME-HPLC) analysis of the phytohormones in cucumber, tomato, date palm, and calendula samples.


Asunto(s)
Quitosano , Glutaral , Reguladores del Crecimiento de las Plantas , Microextracción en Fase Sólida , Titanio , Quitosano/química , Titanio/química , Glutaral/química , Reguladores del Crecimiento de las Plantas/química , Reguladores del Crecimiento de las Plantas/análisis , Materiales Biocompatibles/química , Reactivos de Enlaces Cruzados/química
13.
Chemphyschem ; 25(14): e202400259, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38662530

RESUMEN

Crosslinking is usually required to improve the mechanical properties and stability of collagen-based scaffolds. Introducing exogenous crosslinks into collagen may however affect the collagen structure. Since the architecture of collagen is tied to its functionality, it is important to study the effect of crosslinking and to select a crosslinking method that preserves both the collagen structure and mechanical properties. The objective of this study is to compare the effect of various crosslinking methods on the structure and mechanical properties of bioartificial tendon-like materials (collagen multifilament bundles) fabricated by contact drawing. We examine both physical (ultraviolet light, UVC) and chemical (genipin, carbodiimide (EDC), and glutaraldehyde) crosslinking methods. The presence of collagen and the formation of well-ordered collagen structures are confirmed by attenuated total reflectance Fourier-transform infrared spectromicroscopy and wide-angle X-ray scattering for all crosslinking methods. The morphology of the collagen multifilament bundles is similar across crosslinking methods. Swelling of the multifilament bundles is dramatically reduced following crosslinking and varies by crosslinking method, with genipin- and carbodiimide-crosslinked specimens swelling the least. Ultimate tensile strength (UTS) and Young's modulus significantly improve for all crosslinked specimens compared to non-crosslinked specimens. Glutaraldehyde crosslinked collagen multifilament bundles display the highest UTS values ranging from 33.82±0.0 MPa to 45.59±0.76 MPa.


Asunto(s)
Colágeno , Reactivos de Enlaces Cruzados , Reactivos de Enlaces Cruzados/química , Colágeno/química , Glutaral/química , Rayos Ultravioleta , Carbodiimidas/química , Iridoides/química , Animales , Espectroscopía Infrarroja por Transformada de Fourier , Difracción de Rayos X
14.
J Biotechnol ; 388: 35-48, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38641136

RESUMEN

Whey protein isolate (WPI) was incorporated within calcium pectinate (CPT) beads in order to boost their anionic qualities and meliorate their glutaraldehyde (GA)-polyethyleneimine (PEI) grafting process. The Box-Behnken Design (BBD) verified that WPI inclusion significantly raised the GA-PEI-CPT-WPI beads immobilized ß-D-galactosidase (iß-GLD) activity. The BBD also revealed the optimal settings for WPI concentration, PEI pH, PEI concentration, and GA concentration, which were 2.91 %, 10.8, 3.5 %, and 2.24 %, respectively. The GA-PEI-CPT-WPI beads grafting process was scrutinized via FTIR, EDX, and SEM. The optimal GA-PEI-CPT-WPI immobilizers provided fine ß-GLD immobilization efficiencies, which reached up to 65.28 %. The free and GA-PEI-CPT-WPI iß-GLDs pH and temperature profiles were scrutinized. It was also unveiled that the thermal stability of the iß-GLD surpassed that of its free compeer as it provided lesser kd and ΔS values and larger t1/2, D-values, Ed, ΔH, and ΔG values. Furthermore, the iß-GLD provided 92.00±3.39 % activity after 42 storage days, which denoted its fine storage stability. The iß-GLD short duration (15 min) operational stability was also inspected, and 82.70±0.78 % activity was provided during the fifteenth degradation run. Moreover, the iß-GLD long duration (24 h) operational stability was inspected while degrading the lactose of buffered lactose solution (BLS) and cheese whey (CW). It was unveiled that 81.86±0.96 % and 73.58±2.24 % of the initial glucose were detected during the sixth degradation runs, respectively.


Asunto(s)
Enzimas Inmovilizadas , Polietileneimina , Termodinámica , Proteína de Suero de Leche , Enzimas Inmovilizadas/química , Enzimas Inmovilizadas/metabolismo , Proteína de Suero de Leche/química , Cinética , Polietileneimina/química , Concentración de Iones de Hidrógeno , Pectinas/química , Pectinas/metabolismo , beta-Galactosidasa/metabolismo , beta-Galactosidasa/química , Glutaral/química , Temperatura , Estabilidad de Enzimas
15.
Arch Microbiol ; 206(5): 227, 2024 Apr 20.
Artículo en Inglés | MEDLINE | ID: mdl-38642141

RESUMEN

Bacillus thuringiensis (Bt) and Lysinibacillus sphaericus (Ls) are the most widely used microbial insecticides. Both encounter unfavorable environmental factors and pesticides in the field. Here, the responses of Bt and Ls spores to glutaraldehyde were characterized using Raman spectroscopy and differential interference contrast imaging at the single-cell level. Bt spores were more sensitive to glutaraldehyde than Ls spores under prolonged exposure: <1.0% of Bt spores were viable after 10 min of 0.5% (v/v) glutaraldehyde treatment, compared to ~ 20% of Ls spores. The Raman spectra of glutaraldehyde-treated Bt and Ls spores were almost identical to those of untreated spores; however, the germination process of individual spores was significantly altered. The time to onset of germination, the period of rapid Ca2+-2,6-pyridinedicarboxylic acid (CaDPA) release, and the period of cortex hydrolysis of treated Bt spores were significantly longer than those of untreated spores, with dodecylamine germination being particularly affected. Similarly, the germination of treated Ls spores was significantly prolonged, although the prolongation was less than that of Bt spores. Although the interiors of Bt and Ls spores were undamaged and CaDPA did not leak, proteins and structures involved in spore germination could be severely damaged, resulting in slower and significantly prolonged germination. This study provides insights into the impact of glutaraldehyde on bacterial spores at the single cell level and the variability in spore response to glutaraldehyde across species and populations.


Asunto(s)
Bacillaceae , Bacillus thuringiensis , Insecticidas , Esporas Bacterianas/fisiología , Insecticidas/metabolismo , Glutaral/farmacología , Glutaral/metabolismo , Bacillus subtilis/metabolismo
16.
Biomacromolecules ; 25(4): 2645-2655, 2024 Apr 08.
Artículo en Inglés | MEDLINE | ID: mdl-38456398

RESUMEN

Conventional techniques for the closure of wounds, such as sutures and staples, have significant drawbacks that can negatively impact wound healing. Tissue adhesives have emerged as promising alternatives, but poor adhesion, low mechanical properties, and toxicity have hindered their widespread clinical adoption. In this work, a dual modified, aldehyde and methacrylate hyaluronic acid (HA) biopolymer (HA-MA-CHO) has been synthesized through a simplified route for use as a double cross-linked network (DCN) hydrogel (HA-MA-CHO-DCN) adhesive for the effective closure and sealing of wounds. HA-MA-CHO-DCN cross-links in two stages: initial cross-linking of the aldehyde functionality (CHO) of HA-MA-CHO using a disulfide-containing cross-linker, 3,3'-dithiobis (propionic hydrazide) (DTPH), leading to the formation of a self-healing injectable gel, followed by further cross-linking via ultraviolet (UV) initiated polymerization of the methacrylate (MA) functionality. This hydrogel adhesive shows a stable swelling behavior and remarkable versatility as the storage modulus (G') has shown to be highly tunable (103-105 Pa) for application to many different wound environments. The new HA-MA-CHO-DCN hydrogel showed excellent adhesive properties by surpassing the burst pressure and lap-shear strength for the widely used bovine serum albumin-glutaraldehyde (BSAG) glue while maintaining excellent cell viability.


Asunto(s)
Ácido Hialurónico , Hidrogeles , Hidrogeles/química , Ácido Hialurónico/química , Adhesivos , Glutaral , Metacrilatos
17.
Macromol Biosci ; 24(7): e2400028, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38511568

RESUMEN

Mucosal tissues represent a major interface between the body and the external environment and are covered by a highly hydrated mucins gel called mucus. Mucus lubricates, protects and modulates the moisture levels of the tissue and is capitalized in transmucosal drug delivery. Pharmaceutical researchers often use freshly excised animal mucosal membranes to assess mucoadhesion and muco-penetration of pharmaceutical formulations which may struggle with limited accessibility, reproducibility, and ethical questions. Aiming to develop a platform for the rationale study of the interaction of drugs and delivery systems with mucosal tissues, in this work mucus-mimicking mucin-based hydrogels are synthesized by the tandem chemical and physical crosslinking of mucin aqueous solutions. Chemical crosslinking is achieved with glutaraldehyde (0.3% and 0.75% w/v), while physical crosslinking by one or two freeze-thawing cycles. Hydrogels after one freeze-thawing cycle show water content of 97.6-98.1%, density of 0.0529-0.0648 g cm⁻3, and storage and loss moduli of ≈40-60 and ≈3-5 Pa, respectively, that resemble the properties of native gastrointestinal mucus. The mechanical stability of the hydrogels increases over the number of freeze-thawing cycles. Overall results highlight the potential of this simple, reproducible, and scalable method to produce artificial mucus-mimicking hydrogels for different applications in pharmaceutical research.


Asunto(s)
Reactivos de Enlaces Cruzados , Hidrogeles , Mucinas , Moco , Hidrogeles/química , Hidrogeles/síntesis química , Mucinas/química , Moco/química , Reactivos de Enlaces Cruzados/química , Animales , Glutaral/química , Materiales Biomiméticos/química , Materiales Biomiméticos/farmacología
18.
J Environ Sci (China) ; 142: 115-128, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38527878

RESUMEN

Microscale zero-valent iron (mZVI) has shown great potential for groundwater Cr(VI) remediation. However, low Cr(VI) removal capacity caused by passivation restricted the wide use of mZVI. We prepared mZVI/GCS by encapsulating mZVI in a porous glutaraldehyde-crosslinked chitosan matrix, and the formation of the passivation layer was alleviated by reducing the contact between zero-valent iron particles. The average pore diameter of mZVI/GCS was 8.775 nm, which confirmed the mesoporous characteristic of this material. Results of batch experiments demonstrated that mZVI/GCS exhibited high Cr(VI) removal efficiency in a wide range of pH (2-10) and temperature (5-35°C). Common groundwater coexisting ions slightly affected mZVI/GCS. The material showed great reusability, and the average Cr(VI) removal efficiency was 90.41% during eight cycles. In this study, we also conducted kinetics and isotherms analysis. Pseudo-second-order model was the most matched kinetics model. The Cr(VI) adsorption process was fitted by both Langmuir and Freundlich isotherms models, and the maximum Langmuir adsorption capacity of mZVI/GCS reached 243.63 mg/g, which is higher than the adsorption capacities of materials reported in most of the previous studies. Notably, the column capacity for Cr(VI) removal of a mZVI/GCS-packed column was 6.4 times higher than that of a mZVI-packed column in a 50-day experiment. Therefore, mZVI/GCS with a porous structure effectively relieved passivation problems of mZVI and showed practical application prospects as groundwater Cr(VI) remediation material with practical application prospects.


Asunto(s)
Quitosano , Agua Subterránea , Contaminantes Químicos del Agua , Hierro/química , Glutaral , Longevidad , Contaminantes Químicos del Agua/química , Cromo/análisis , Agua Subterránea/química , Adsorción
19.
J Contemp Dent Pract ; 25(1): 52-57, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38514431

RESUMEN

AIM: The aim of this study was to assess the impact of Nd:YAG laser, glutaraldehyde-based desensitizer (GD), or their combination on occluding dentinal tubules. MATERIALS AND METHODS: Fifty dentin samples were obtained from non-carious human third molars and randomly divided into five groups (n = 10): (1) Control group treated with 37% phosphoric acid, (2) GD group, (3) Nd:YAG laser group (1064 nm, 100 µs, 10 Hz, 300 µm fiber, 1 W power, 100 mJ energy, and 85 J/cm2 energy density), (4) GD followed by Nd:YAG laser group, and (5) Nd:YAG laser followed by GD group. Scanning electron microscopy (SEM) was used to capture five images from each sample for analysis of dentinal tubules using Image J software. SEM/EDX elemental analysis was performed to determine the main mineral contents. Data analyzed using one-way ANOVA and Tukey's post hoc test for statistical comparisons. RESULTS: Laser and combination groups showed a significant decrease in dentinal tubule counts compared with the control and GD groups (p < 0.0001). There were no significant differences in open dentinal tubule counts between the control and GD groups, as well as between the laser and combination groups. However, significant differences were observed in the total area, average size of the tubules, and percentage area between the control group and the treatment groups (GD, laser, GD + laser, laser + GD). No significant difference was found in the Ca/P ratio between the tested groups. CONCLUSION: The use of Nd:YAG laser alone or in combination with GD was more effective in occluding dentinal tubules compared to GD alone. CLINICAL SIGNIFICANCE: This study has shown that Nd:YAG laser alone and in combination with GD has superior dentinal tubule occlusion in vitro. Its clinical use in the treatment of dentinal hypersensitivity may overcome the drawback of conventional treatment approaches for dentin hypersensitivity needing repeated applications to achieve continuous relief from pain since acidic diet and toothbrushing result in the continuing elimination of precipitates and surface coatings. How to cite this article: Alzarooni AH, El-Damanhoury HM, Aravind SS, et al. Combined Effects of Glutaraldehyde-based Desensitizer and Nd: YAG Laser on Dentinal Tubules Occlusion. J Contemp Dent Pract 2024;25(1):52-57.


Asunto(s)
Sensibilidad de la Dentina , Láseres de Estado Sólido , Humanos , Láseres de Estado Sólido/uso terapéutico , Dentina , Sensibilidad de la Dentina/tratamiento farmacológico , Glutaral/farmacología , Glutaral/uso terapéutico , Tercer Molar , Microscopía Electrónica de Rastreo
20.
J Mater Chem B ; 12(14): 3417-3435, 2024 Apr 03.
Artículo en Inglés | MEDLINE | ID: mdl-38525920

RESUMEN

Due to the increasing aging population and the advancements in transcatheter aortic valve replacement (TAVR), the use of bioprosthetic heart valves (BHVs) in patients diagnosed with valvular disease has increased substantially. Commercially available glutaraldehyde (GA) cross-linked biological valves suffer from reduced durability due to a combination of factors, including the high cell toxicity of GA, subacute thrombus, inflammation and calcification. In this study, oxidized chondroitin sulfate (OCS), a natural polysaccharide derivative, was used to replace GA to cross-link decellularized bovine pericardium (DBP), carrying out the first crosslinking of DBP to obtain OCS-BP. Subsequently, the zwitterion radical copolymerization system was introduced in situ to perform double cross-linking to obtain double crosslinked BHVs with biomimetic modification (P(APM/MPC)-OCS-BP). P(APM/MPC)-OCS-BP presented enhanced mechanical properties, collagen stability and enzymatic degradation resistance due to double crosslinking. The ex vivo AV-shunt assay and coagulation factors test suggested that P(APM/MPC)-OCS-BP exhibited excellent anticoagulant and antithrombotic properties due to the introduction of P(APM/MPC). P(APM/MPC)-OCS-BP also showed good HUVEC-cytocompatibility due to the substantial reduction of its residual aldehyde group. The subcutaneous implantation also demonstrated that P(APM/MPC)-OCS-BP showed a weak inflammatory response due to the anti-inflammatory effect of OCS. Finally, in vivo and in vitro results revealed that P(APM/MPC)-OCS-BP exhibited an excellent anti-calcification property. In a word, this simple cooperative crosslinking strategy provides a novel solution to obtain BHVs with good mechanical properties, and HUVEC-cytocompatibility, anti-coagulation, anti-inflammatory and anti-calcification properties. It might be a promising alternative to GA-fixed BP and exhibited good prospects in clinical applications.


Asunto(s)
Calcinosis , Prótesis Valvulares Cardíacas , Humanos , Animales , Bovinos , Anciano , Sulfatos de Condroitina/farmacología , Reactivos de Enlaces Cruzados/farmacología , Válvulas Cardíacas , Glutaral , Antiinflamatorios/farmacología , Pericardio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...