Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 469
Filtrar
1.
BMJ Open Ophthalmol ; 9(1)2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38969362

RESUMEN

OBJECTIVES: This study aimed to quantitatively evaluate optic nerve head and retinal vascular parameters in children with hyperopia in relation to age and spherical equivalent refraction (SER) using artificial intelligence (AI)-based analysis of colour fundus photographs (CFP). METHODS AND ANALYSIS: This cross-sectional study included 324 children with hyperopia aged 3-12 years. Participants were divided into low hyperopia (SER+0.5 D to+2.0 D) and moderate-to-high hyperopia (SER≥+2.0 D) groups. Fundus parameters, such as optic disc area and mean vessel diameter, were automatically and quantitatively detected using AI. Significant variables (p<0.05) in the univariate analysis were included in a stepwise multiple linear regression. RESULTS: Overall, 324 children were included, 172 with low and 152 with moderate-to-high hyperopia. The median optic disc area and vessel diameter were 1.42 mm2 and 65.09 µm, respectively. Children with high hyperopia had larger superior neuroretinal rim (NRR) width and larger vessel diameter than those with low and moderate hyperopia. In the univariate analysis, axial length was significantly associated with smaller superior NRR width (ß=-3.030, p<0.001), smaller temporal NRR width (ß=-1.469, p=0.020) and smaller vessel diameter (ß=-0.076, p<0.001). A mild inverse correlation was observed between the optic disc area and vertical disc diameter with age. CONCLUSION: AI-based CFP analysis showed that children with high hyperopia had larger mean vessel diameter but smaller vertical cup-to-disc ratio than those with low hyperopia. This suggests that AI can provide quantitative data on fundus parameters in children with hyperopia.


Asunto(s)
Inteligencia Artificial , Hiperopía , Disco Óptico , Fotograbar , Vasos Retinianos , Humanos , Hiperopía/diagnóstico , Hiperopía/fisiopatología , Estudios Transversales , Masculino , Niño , Femenino , Preescolar , Disco Óptico/diagnóstico por imagen , Disco Óptico/patología , Disco Óptico/irrigación sanguínea , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Fotograbar/métodos , Fondo de Ojo , Agudeza Visual/fisiología , Refracción Ocular/fisiología
2.
Am J Ophthalmol ; 264: 99-103, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38579921

RESUMEN

PURPOSE: To evaluate Spot in detecting American Association for Pediatric Ophthalmology and Strabismus (AAPOS) Amblyopia risk factors (ARF) and for ARF myopia and hyperopia with variations in ocular pigments. DESIGN: Diagnostic screening test evaluation. METHODS: Study population: Children presented for a complete eye examination in pediatric clinic. The study population included 1040 participants, of whom 273 had darkly pigmented eyes, 303 were medium pigmented, and 464 were light pigmented. INTERVENTION: Children were screened with the Spot vision screener before the complete eye examination. A pediatric ophthalmologist then completed an eye examination, including cycloplegic refraction. The pediatric ophthalmologist was blinded to the result of the Spot vision screener. MAIN OUTCOME: The association between Spot screening recommendation and meeting one or more ARF/ARF + Amblyopia criterion, Spot measured spherical equivalent, and ARF myopia and hyperopia detection. RESULTS: The area under the receiver operative characteristic curve (AUC) for myopia was excellent for all. The AUC for hyperopia was good (darker-pigmented: 0.92, medium-pigmented: 0.81, and lighter-pigmented: 0.86 eyes). The Spot was most sensitive for ARF myopia (lighter-pigmented: 0.78, medium-pigmented: 0.52, darker-pigmented: 0.49). The reverse was found for hyperopia; however, sensitivity was relatively poor. The Spot was found most sensitive for hyperopia in the darker-pigment group (0.46), 0.27 for medium-pigment, and 0.23 for the lighter-pigment cohort. CONCLUSIONS: While the Spot was confirmed as a sensitive screening test with good specificity in our large cohort, the sensitivity of the Spot in detecting AAPOS guidelines for myopia and hyperopia differed with variations in skin pigment. Our results support the consideration of ethnic and racial diversity in future advances in photorefractor technology.


Asunto(s)
Ambliopía , Hiperopía , Miopía , Curva ROC , Selección Visual , Humanos , Masculino , Femenino , Hiperopía/diagnóstico , Hiperopía/fisiopatología , Miopía/diagnóstico , Miopía/fisiopatología , Niño , Selección Visual/métodos , Selección Visual/instrumentación , Preescolar , Ambliopía/diagnóstico , Ambliopía/fisiopatología , Color del Ojo , Factores de Riesgo , Sensibilidad y Especificidad , Refracción Ocular/fisiología , Área Bajo la Curva , Pigmentos Retinianos/metabolismo , Reproducibilidad de los Resultados , Adolescente
3.
Invest Ophthalmol Vis Sci ; 65(4): 14, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38578621

RESUMEN

Purpose: This study aims to examine the short-term peripheral choroidal thickness (PChT) response to signed defocus blur, both with and without native peripheral aberrations. This examination will provide insights into the role of peripheral aberration in detecting signs of defocus. Methods: The peripheral retina (temporal 15°) of the right eye was exposed to a localized video stimulus in 11 young adults. An adaptive optics system induced 2D myopic or hyperopic defocus onto the stimulus, with or without correcting native peripheral ocular aberrations (adaptive optics [AO] or NoAO defocus conditions). Choroidal scans were captured using Heidelberg Spectralis OCT at baseline, exposure (10, 20, and 30 minutes), and recovery phases (4, 8, and 15 minutes). Neural network-based automated MATLAB segmentation program measured PChT changes from OCT scans, and statistical analysis evaluated the effects of different optical conditions over time. Results: During the exposure phase, NoAO myopic and hyperopic defocus conditions exhibited distinct bidirectional PChT alterations, showing average thickening (10.0 ± 5.3 µm) and thinning (-9.1 ± 5.5 µm), respectively. In contrast, induced AO defocus conditions did not demonstrate a significant change from baseline. PChT recovery to baseline occurred for all conditions. The unexposed fovea did not show any significant ChT change, indicating a localized ChT response to retinal blur. Conclusions: We discovered that the PChT response serves as a marker for detecting peripheral retinal myopic and hyperopic defocus blur, especially in the presence of peripheral aberrations. These findings highlight the significant role of peripheral oriented blur in cueing peripheral defocus sign detection.


Asunto(s)
Hiperopía , Miopía , Adulto Joven , Humanos , Miopía/diagnóstico , Hiperopía/diagnóstico , Coroides , Retina , Fóvea Central , Refracción Ocular
4.
Curr Eye Res ; 49(7): 768-775, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38616539

RESUMEN

PURPOSE: This study aims to elucidate the longitudinal refractive and ocular biometric alterations in preschool children with high hyperopia who underwent early interventions. METHODS: We conducted a retrospective analysis of preschool children diagnosed with high hyperopia at Tianjin Medical University Eye Hospital between 2011 and 2023. Inclusion criteria required an initial examination with cycloplegic refraction, bilateral spherical equivalent power (SE) ≥ +5.00D with a difference <1.00D, a minimum two-year follow-up, and at least three ocular biometric measurements. The annual axial growth rate evaluated emmetropization in highly hyperopic children. We applied Restricted Cubic Spline (RCS) models to explore potential nonlinear relationships between age and spherical equivalent, axial length, corneal curvature, and axial length-to-corneal curvature ratio. Additionally, Mixed-effects models were employed to investigate factors associated with changes in refractive error and axial length. RESULTS: The study enrolled 60 eligible subjects, with a median initial diagnosis age of 3.5 years (IQR, 2.8-4.9 years) and a median last visit age of 9.3 years (IQR, 8.1-10.8 years). The average follow-up duration was 5.7 years. RCS analysis revealed notable nonlinear changes in spherical equivalent power, axial length, and axial length-to-corneal curvature ratio, although corneal curvature displayed no statistically significant nonlinear trend. Factors affecting SE changes included the presence of strabismus, the use of cycloplegia, baseline SE, and age. Conversely, changes in axial length solely correlated with baseline axial length and age. CONCLUSION: Highly hyperopic preschool children undergoing early intervention display a marked emmetropization tendency, though most still remain moderately to highly hyperopic, with the progression of refractive changes showing non-uniform patterns with respect to age.


Asunto(s)
Longitud Axial del Ojo , Hiperopía , Refracción Ocular , Humanos , Hiperopía/fisiopatología , Hiperopía/diagnóstico , Preescolar , Refracción Ocular/fisiología , Masculino , Estudios Retrospectivos , Femenino , Estudios de Seguimiento , Longitud Axial del Ojo/patología , Agudeza Visual/fisiología , Niño , Biometría , Córnea/fisiopatología , Córnea/patología , Enfermedades Hereditarias del Ojo
5.
Eye (Lond) ; 38(10): 1891-1896, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38555400

RESUMEN

BACKGROUND/OBJECTIVES: Tessellated fundus can exist in normal healthy eyes. This study aims to evaluate the occurrence and influencing factors of tessellated fundus in preschool children aged 3-6 years. SUBJECTS/METHODS: This kindergarten-based cross-sectional study included 1716 children with an age range of 3-6 years. All participants underwent a comprehensive eye examination and a questionnaire. According to the number of quadrants occupied by tessellated fundus around the optic disc in fundus photographs, it was divided into four grades. RESULTS: 600 (35.0%) children had peripapillary tessellation. According to the spherical equivalent (SE), the subjects were divided into three groups: Hyperopia group (SE > + 0.75D, n = 1194);Pre-myopia group (-0.50D < SE ≤ + 0.75D, n = 455); Myopia group (SE ≤ -0.50D, n = 67). The proportion of peripapillary tessellated fundus was 33.0%, 38.0%, 50.7% respectively. According to the regression analysis, in the non-myopia group (Pre-myopia group and Hyperopia group), the occurrence of peripapillary tessellated fundus was associated with longer axial length (OR, 1.566; 95% CI: 1.229-1.996, p < 0.001) and larger corneal radius of curvature (OR, 1.837; 95% CI: 1.006-3.354, p = 0.048). However, in Pre-myopia group, the corneal radius of curvature was not associated with the occurrence of peripapillary tessellated fundus (p = 0.830). In Hyperopia group, the corneal radius of curvature was associated with the occurrence of peripapillary tessellated fundus (OR, 2.438; 95% CI: 1.160-5.122, p = 0.019). CONCLUSIONS: The occurrence of peripapillary tessellated fundus is more than 30% in 3-6 year old preschool children. Tessellated fundus can also occur in non-myopic children, and is related to the length of axial length and large radius of corneal curvature.


Asunto(s)
Fondo de Ojo , Miopía , Humanos , Estudios Transversales , Masculino , Femenino , Preescolar , Niño , Miopía/diagnóstico , Miopía/fisiopatología , Miopía/epidemiología , Disco Óptico/patología , Disco Óptico/diagnóstico por imagen , Refracción Ocular/fisiología , Agudeza Visual/fisiología , Encuestas y Cuestionarios , Hiperopía/diagnóstico , Hiperopía/fisiopatología , Longitud Axial del Ojo/patología
6.
Ophthalmic Physiol Opt ; 44(3): 501-513, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38504505

RESUMEN

PURPOSE: This study evaluated the ability of QuickSee to detect children at risk for significant vision conditions (significant refractive error [RE], amblyopia and strabismus). METHODS: Non-cycloplegic refraction (using QuickSee without and with +2 dioptre (D) fogging lenses) and unaided binocular near visual acuity (VA) were measured in 4- to 12-year-old children. Eye examination findings (VA, cover testing and cycloplegic retinoscopy) were used to determine the presence of vision conditions. QuickSee performance was summarised by area under the receiver operating characteristic curve (AUC), sensitivity and specificity for various levels of RE. QuickSee referral criteria for each vision condition were chosen to maximise sensitivity at a specificity of approximately 85%-90%. Sensitivity and specificity to detect vision conditions were calculated using multiple criteria. Logistic regression was used to evaluate the benefit of adding near VA (6/12 or worse) for detecting hyperopia. A paired t-test compared QuickSee without and with fogging lenses. RESULTS: The mean age was 8.2 (±2.5) years (n = 174). RE ranged up to 9.25 D myopia, 8 D hyperopia, 5.25 D astigmatism and 3.5 D anisometropia. The testability of the QuickSee was 94.3%. AUC was ≥0.92 (excellent) for each level of RE. For the detection of any RE, sensitivity and specificity were 84.2% and 87.3%, respectively, using modified Orinda criteria and 94.5% and 78.2%, respectively, using the American Academy for Pediatric Ophthalmology and Strabismus (AAPOS) guidelines. For the detection of any significant vision condition, the sensitivity and specificity of QuickSee were 81.1% and 87.9%, respectively, using modified Orinda criteria and 93% and 78.6%, respectively, using AAPOS criteria. There was no significant benefit of adding near VA to QuickSee for the detection of hyperopia ≥+2.00 (p = 0.34). There was no significant difference between QuickSee measurements of hyperopic refractive error with and without fogging lenses (difference = -0.09 D; p = 0.51). CONCLUSIONS: QuickSee had high discriminatory power for detecting children with hyperopia, myopia, astigmatism, anisometropia, any significant refractive error or any significant vision condition.


Asunto(s)
Anisometropía , Astigmatismo , Hiperopía , Miopía , Errores de Refracción , Estrabismo , Selección Visual , Niño , Humanos , Preescolar , Hiperopía/diagnóstico , Astigmatismo/diagnóstico , Errores de Refracción/diagnóstico , Estrabismo/diagnóstico
7.
Sci Rep ; 14(1): 254, 2024 01 02.
Artículo en Inglés | MEDLINE | ID: mdl-38168543

RESUMEN

This study aims to investigate the prevalence of visual impairments, such as myopia, hyperopia, and astigmatism, among school-age children (7-9 years) in Lubelskie Voivodeship (Republic of Poland) and apply artificial intelligence (AI) in the detection of severe ocular diseases. A total of 1049 participants (1.7% of the total child population in the region) were examined through a combination of standardized visual acuity tests, autorefraction, and assessment of fundus images by a convolutional neural network (CNN) model. The results from this artificial intelligence (AI) model were juxtaposed with assessments conducted by two experienced ophthalmologists to gauge the model's accuracy. The results demonstrated myopia, hyperopia, and astigmatism prevalences of 3.7%, 16.9%, and 7.8%, respectively, with myopia showing a significant age-related increase and hyperopia decreasing with age. The AI model performance was evaluated using the Dice coefficient, reaching 93.3%, indicating that the CNN model was highly accurate. The study underscores the utility of AI in the early detection and diagnosis of severe ocular diseases, providing a foundation for future research to improve paediatric ophthalmic screening and treatment outcomes.


Asunto(s)
Astigmatismo , Hiperopía , Miopía , Errores de Refracción , Humanos , Niño , Astigmatismo/epidemiología , Hiperopía/diagnóstico , Hiperopía/epidemiología , Inteligencia Artificial , Estudios de Cohortes , Miopía/epidemiología , Prevalencia , Errores de Refracción/diagnóstico , Errores de Refracción/epidemiología
8.
Ophthalmic Res ; 67(1): 115-124, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-37989114

RESUMEN

INTRODUCTION: The aim of this study was to explore the association between parental myopia and high myopia with children's refraction and ocular biometry in large-scale Chinese preschool children from the Beijing Hyperopia Reserve Study. SUBJECTS/METHODS: This cross-sectional kindergarten-based study enrolled children aged 3-6 years. Cycloplegic refraction, axial length (AL), and corneal radius (CR) were measured for all children. Parents were asked to complete a questionnaire about refractive status (no myopia, mild myopia <-3 D, moderate myopia ≥-3 D and ≤-6, and high myopia >-6 D). RESULTS: The study enrolled 2,053 children (1,069 boys and 984 girls), with a mean age of 4.26 ± 0.96 years and mean spherical equivalent refraction (SER) of 1.11 ± 0.97 diopter. Of the children, 90.7% had at least one myopic parent, and 511 children (24.9%) had at least one highly myopic parent. SER decreased significantly with increasing severity of parental myopia (p < 0.001). Preschool children's myopia was independently associated with parental myopia (OR, 10.4 and 11.5 for one and two highly myopic parent[s]). Age (OR = 1.1), gender (OR = 1.7; girls as references), near work time (OR = 1.2), and both maternal (OR, 1.4 and 2.0 for moderate and high myopia) and paternal myopia (OR, 1.6 and 1.9 for moderate and high myopia) were independent risk factors for lacking hyperopia reserve. CONCLUSION: Severe parental myopia was associated with a lower SER, longer AL, and higher AL/CR ratio in preschool children. Parental myopia and near work may predispose children to faster elimination of hyperopia reserves before exposure to higher educational stress.


Asunto(s)
Hiperopía , Miopía , Masculino , Femenino , Humanos , Preescolar , Hiperopía/diagnóstico , Estudios Transversales , Miopía/diagnóstico , Refracción Ocular , Padres , Córnea , Biometría
9.
Am J Ophthalmol ; 258: 130-138, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37517526

RESUMEN

PURPOSE: Nonsurgical consecutive exotropia (NCX) occurs when an esotropia (ET) spontaneously converts to exotropia (XT) without surgical intervention. Although NCX is considered to occur in early-onset accommodative ET with high hyperopia, consensus on causation is lacking. We report the clinical characteristics of NCX and assess the response to conservative management. DESIGN: Retrospective, multicenter, observational case series. METHODS: Patients aged 6 months and older with an initial diagnosis of ET who converted to XT without surgical intervention. Sensory strabismus was excluded. Age, visual acuity, cycloplegic refraction, glasses prescriptions, deviation, and binocular vision were collected. RESULTS: Forty-nine children were included with a mean age of 3.5 ± 1.6 years and 8.4 ± 3.6 years at the time of ET and NCX, respectively. Mean refractive error was +4.40 ± 2.13 diopters (D) and +4.05 ± 2.74 D at the time of ET and NCX, respectively. Accommodative ET occurred in 60% of cases, and only 35.7% were high hyperopes. All but 1 patient presented with XT at distance. In response to the XT, a mean decrease in hyperopic prescription of 1.55 ± 0.48 D was given (N = 17); only 1 case reverted to ET. Eventually, 43% underwent XT surgery, with similar rates between those who had refractive management and those who did not. CONCLUSIONS: NCX occurs in both accommodative and nonaccommodative ET; high hyperopia is present in only one-third of cases. On average, drift to XT occurs within 5 years. Refractive management has a modest result. No predictive risk factors were identified. Our findings challenge hyperopia-linked theories of causation. Nonrefractive explanations, such as the role of the vergence system, deserve further study.


Asunto(s)
Esotropía , Exotropía , Enfermedades Hereditarias del Ojo , Hiperopía , Estrabismo , Niño , Preescolar , Humanos , Lactante , Acomodación Ocular , Esotropía/terapia , Esotropía/cirugía , Exotropía/diagnóstico , Exotropía/terapia , Estudios de Seguimiento , Hiperopía/diagnóstico , Hiperopía/terapia , Estudios Retrospectivos , Estrabismo/complicaciones , Visión Binocular/fisiología
10.
Ophthalmic Physiol Opt ; 44(1): 42-51, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37787443

RESUMEN

INTRODUCTION: Hyperopia is associated with reduced vision and educational outcomes in schoolchildren. This study explored the impact of clinically significant hyperopia (≥+2.00 D) on visual function in schoolchildren and compared the ability of different screening tests (alone and in combination) to detect this level of hyperopia. METHODS: Vision testing including monocular logMAR visual acuity (VA) measured to threshold (distance [DVA], near [NVA] and DVA through a plus lens [+2.50 D]), stereoacuity and cycloplegic autorefraction (tropicamide 1%) were undertaken on 263 schoolchildren (mean age: 11.76 years ± 3.38) in Queensland, Australia. Vision measures were compared between children with clinically significant hyperopia in at least one meridian (≥+2.00 D) and emmetropia/low hyperopia (>0.00 and <+2.00 D). Receiver operating curve (ROC) analysis was performed to identify optimal pass/fail criteria for each test and the diagnostic accuracy of individual and combinations of tests. RESULTS: Thirty-two children had clinically significant hyperopia and 225 had emmetropia/low hyperopia. DVA and NVA were worse (p < 0.01), while the difference in DVA through a plus lens was less in children with clinically significant hyperopia (p < 0.01). ROC analysis for individual tests resulted in areas under the curve (AUCs) ranging from 0.65 to 0.85. Combining screening tests revealed that failing one or more of the following tests was most effective for detecting hyperopia: DVA, NVA and difference in DVA through a plus lens, resulting in a sensitivity and specificity of 72% and 81%, respectively. CONCLUSION: Significant differences in visual function existed between schoolchildren with clinically significant hyperopia and emmetropia/low hyperopia. Combining measures of DVA and NVA and the difference in DVA through a plus lens demonstrated good discriminative ability for detecting clinically significant hyperopia in this population.


Asunto(s)
Hiperopía , Selección Visual , Niño , Humanos , Hiperopía/diagnóstico , Agudeza Visual , Pruebas de Visión , Emetropía , Sensibilidad y Especificidad , Selección Visual/métodos
11.
BMJ Open ; 13(12): e075115, 2023 12 30.
Artículo en Inglés | MEDLINE | ID: mdl-38159956

RESUMEN

OBJECTIVE: This study aims to investigate the associations of axial length to corneal radius of curvature (AL/CRC) ratio with refractive error and to determine the effect of AL/CRC ratio on hyperopia reserve and myopia assessment among Chinese preschoolers. METHODS: This was a retrospective cross-sectional study that evaluated subjects aged 4-6 years. AL and CRC were obtained using a non-contact ocular biometer. Correlation analysis was performed to explore the associations of AL/CRC ratio with spherical equivalent refractive error (SER). The accuracy of AL/CRC ratio for hyperopia reserve and myopia assessment was analysed using cycloplegic refraction by drawing receiver operating characteristic (ROC) curves. RESULTS: The analysis included 1024 participants (537 boys, 52.4%). The mean AL/CRC ratios in hyperopes, emmetropes and myopes were 2.90±0.06, 2.95±0.05 and 3.08±0.07, respectively. The SER was found to be more strongly correlated with AL/CRC ratio (ρ=-0.66, p<0.001) than either AL or CRC alone (ρ=-0.52, p<0.001; ρ=-0.03, p=0.33, respectively). AL/CRC was correlated with SER in hyperopes (ρ=-0.54, p<0.001), emmetropes (ρ=-0.33, p<0.001) and myopes (r=-0.67, p<0.001). For low hyperopia reserve assessment, the area under the ROC curves of AL/CRC ratio was 0.861 (95% CI 0.829 to 0.892), the optimal cut-off value of the AL/CRC ratio was ≥2.955. For myopia assessment, the area under the ROC curves of AL/CRC ratio was 0.954 (95% CI 0.925 to 0.982), the optimal cut-off value of the AL/CRC ratio was ≥2.975. CONCLUSIONS: The SER showed a better correlation with AL/CRC ratio than either AL or CRC alone, especially in myopes, among children aged 4-6 years. These findings indicate that when cycloplegic refraction is unavailable, AL/CRC ratio could be used as an alternative indicator for identifying low hyperopia reserve and myopia among preschoolers, helping clinicians and parents screen children with low hyperopia reserve before primary school in a timely manner.


Asunto(s)
Hiperopía , Miopía , Errores de Refracción , Masculino , Niño , Humanos , Hiperopía/diagnóstico , Estudios Transversales , Refracción Ocular , Estudios Retrospectivos , Midriáticos , Radio (Anatomía) , Errores de Refracción/diagnóstico , Córnea , Miopía/diagnóstico , China/epidemiología
12.
BMC Ophthalmol ; 23(1): 487, 2023 Nov 27.
Artículo en Inglés | MEDLINE | ID: mdl-38012552

RESUMEN

PURPOSE: By comparing the results of the new self-contained darkroom refractive screener (YD-SX-A) versus table-top autorefractor and cycloplegic retinoscopy, to evaluate the performance of the YD-SX-A in detecting refractive error in children and adolescents and then judge whether it can be used in refractive screening. METHODS: Cross-sectional study. 1000 participants between the ages of 6 and 18 who visited the Optometry Center of the People's Hospital of Guangxi Zhuang Autonomous Region from June to December 2022 were selected. First, participants were instructed to measure their diopter with a table-top autorefractor (Topcon KR8800) and YD-SX-A in a noncycloplegic setting. After cycloplegia, they were retinoscopy by a professional optometrist. The results measured by three methods were collected respectively. To avoid deviation, only the right eye (1000 eyes) data were used in the statistical analysis. The Bland-Altman plots were used to evaluate the agreement of diopters measured by the three methods. The receiver operating characteristic (ROC) curves was used to analysis effectiveness of detecting refractive error of YD-SX-A. RESULTS: The average age of participants was 10.77 ± 3.00 years, including 504 boys (50.4%) and 496 girls (49.6%). When YD-SX-A and cycloplegia retinoscopy (CR) were compared in the myopia group, there was no statistical difference in spherical equivalent (SE) (P > 0.05), but there was a statistical difference in diopter spherical (DS) and diopter cylinder (DC) (P < 0.05). Comparing the diopter results of Topcon KR8800 and CR, the difference between each test value in the myopia group was statistically significant (P < 0.05). In the hyperopia group, the comparison between YD-SX-A and CR showed no statistically significant differences in the DC (P > 0.05), but there were significant differences in the SE and DS (P < 0.05). In the astigmatism group, the SE, DS, and DC were statistically different, and the DC of YD-SX-A was lower than that of CR and Topcon KR8800. Bland-Altman plots indicated that YD-SX-A has a moderate agreement with CR and Topcon KR8800. The sensitivity and specificity of YD-SX-A for detecting myopia, hyperopia and astigmatism were 90.17% and 90.32%, 97.78% and 87.88%, 84.08% and 74.26%, respectively. CONCLUSION: This study has identified that YD-SX-A has shown good performance in both agreement and effectiveness in detecting refractive error when compared with Topcon KR8800 and CR. YD-SX-A could be a useful tool for large-scale population refractive screening.


Asunto(s)
Trastornos de la Pupila , Errores de Refracción , Retinoscopía , Selección Visual , Adolescente , Niño , Femenino , Humanos , Masculino , Astigmatismo/diagnóstico , China/epidemiología , Estudios Transversales , Hiperopía/diagnóstico , Miopía/diagnóstico , Optometría , Presbiopía/diagnóstico , Trastornos de la Pupila/diagnóstico , Trastornos de la Pupila/epidemiología , Refracción Ocular , Errores de Refracción/diagnóstico , Errores de Refracción/epidemiología , Retinoscopía/métodos , Selección Visual/métodos
13.
Braz J Psychiatry ; 45(5): 397-404, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37718319

RESUMEN

OBJECTIVES: The present study analyzed the reciprocal relationships between four common pediatric ophthalmic diseases (i.e., hyperopia, myopia, astigmatism, and strabismus) and attention-deficit/hyperactivity disorder (ADHD) in children. METHODS: This study enrolled 86,028 children with ADHD and 1,798,673 children without ADHD in the Taiwan Maternal and Child Health Database who were born at any time from 2004 to 2017. Cox proportional hazards regression models were used to estimate the bidirectional relationships of the four ophthalmic diseases with ADHD in children after adjusting for age, sex, and gestational age at birth. Survival curves for time-to-event variables were estimated using the Kaplan-Meier method, and the log-rank test was used to compare the curves. RESULTS: The results indicated that ADHD significantly predicted the occurrence of hyperopia, myopia, astigmatism, and strabismus. Furthermore, hyperopia, myopia, astigmatism, and strabismus significantly predicted the occurrence of ADHD. The time between enrollment and ADHD diagnosis was shorter for patients with ophthalmic diseases than for the control group, and the time between enrollment and ophthalmic disease diagnosis was also shorter for ADHD patients than for the control group. Sex differences were found in the associations between ADHD and ophthalmic diseases. CONCLUSION: Clinicians should monitor children with ADHD for hyperopia, myopia, astigmatism, and strabismus to ensure appropriate treatment, and vice versa.


Asunto(s)
Astigmatismo , Trastorno por Déficit de Atención con Hiperactividad , Hiperopía , Miopía , Estrabismo , Recién Nacido , Humanos , Niño , Femenino , Masculino , Astigmatismo/complicaciones , Astigmatismo/diagnóstico , Astigmatismo/epidemiología , Hiperopía/epidemiología , Hiperopía/complicaciones , Hiperopía/diagnóstico , Trastorno por Déficit de Atención con Hiperactividad/epidemiología , Estudios de Cohortes , Miopía/complicaciones , Miopía/diagnóstico , Miopía/epidemiología , Estrabismo/epidemiología , Estrabismo/complicaciones , Estrabismo/diagnóstico
14.
Transl Vis Sci Technol ; 12(8): 14, 2023 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-37594450

RESUMEN

Purpose: Treatments are available to slow myopic axial elongation. Understanding normal axial length (AL) distributions will assist clinicians in choosing appropriate treatment for myopia. We report the distribution of AL in Australians of different age groups and refractive errors. Methods: Retrospectively collected spherical equivalent refraction (SER) and AL data of 5938 individuals aged 5 to 89 years from 8 Australian studies were included. Based on the SER, participants were classified as emmetropes, myopes, and hyperopes. Two regression model parameterizations (piece-wise and restricted cubic splines [RCS]) were applied to the cross-sectional data to analyze the association between age and AL. These results were compared with longitudinal data from the Raine Study where the AL was measured at age 20 (baseline) and 28 years. Results: A piece-wise regression model (with 1 knot) showed that myopes had a greater increase in AL before 18 years by 0.119 mm/year (P < 0.001) and after 18 years by 0.011 mm/year (P < 0.001) compared to emmetropes and hyperopes, with the RCS model (with 3 knots) showing similar results. The longitudinal data from the Raine Study revealed that, when compared to emmetropes, only myopes showed a significant change in the AL in young adulthood (by 0.016 mm/year, P < 0.001). Conclusions: The AL of myopic eyes increases more rapidly in childhood and slightly in early adulthood. Further studies of longitudinal changes in AL, particularly in childhood, are required to guide myopia interventions. Translational Relevance: The axial length of myopic eyes increases rapidly in childhood, and there is a minimal increase in the axial length in non-myopic eyes after 18 years of age.


Asunto(s)
Emetropía , Ojo , Hiperopía , Miopía , Errores de Refracción , Adolescente , Adulto , Humanos , Adulto Joven , Australia/epidemiología , Estudios Transversales , Hiperopía/diagnóstico , Hiperopía/epidemiología , Miopía/diagnóstico , Miopía/epidemiología , Errores de Refracción/epidemiología , Estudios Retrospectivos , Preescolar , Niño , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años , Tamaño de los Órganos , Ojo/crecimiento & desarrollo , Ojo/patología
16.
Graefes Arch Clin Exp Ophthalmol ; 261(10): 3015-3022, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37199799

RESUMEN

AIM: This study aimed to evaluate the visual outcomes and corneal densitometry (CD) after allogenic lenticule intrastromal keratoplasty (AL-LIKE) and autologous lenticule intrastromal keratoplasty (AU-LIKE) for the correction of moderate-to-high hyperopia. METHODS: Ten subjects (14 eyes) underwent AL-LIKE and eight (8 eyes) underwent AU-LIKE. Patients were examined preoperatively and 1 day, 1 month, and 6 months postoperatively. The visual outcomes and CD for both surgical methods were evaluated. RESULTS: No postoperative complications were observed with either method. The efficacy index was 0.85±0.18 and 0.90±0.33 in the AL-LIKE and AU-LIKE groups, respectively. The safety indices were 1.07±0.21 and 1.25±0.37 in the AL-LIKE and AU-LIKE groups, respectively. The CD values of the anterior, central, and posterior layers in the AL-LIKE group increased significantly at 1 day postoperatively (all P < 0.05). The CD values of the anterior and central layers remained significantly higher than the preoperative values at 6 months postoperatively (all P < 0.05). The CD values of the anterior layer in the AU-LIKE group increased significantly 1 day postoperatively (all P < 0.05) and decreased to preoperative values (all P > 0.05) 1 month postoperatively. CONCLUSION: Both AL-LIKE and AU-LIKE exhibit good efficacy and safety in correcting hyperopia. However, AU-LIKE may have a smaller affected area and faster recovery time than those associated with AU-LIKE related to changes in corneal transparency.


Asunto(s)
Trasplante de Córnea , Hiperopía , Humanos , Sustancia Propia/cirugía , Hiperopía/diagnóstico , Hiperopía/cirugía , Agudeza Visual , Trasplante de Córnea/métodos , Densitometría
17.
Indian J Ophthalmol ; 71(5): 1941-1947, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37203062

RESUMEN

Purpose: To evaluate the refractive status and ocular biometric parameters in primary angle-closure glaucoma (PACG) eyes with different axial lengths (ALs). Methods: In total, 742 Chinese PACG subjects with complete ophthalmic examinations were enrolled. The refractive status was categorized as myopia (spherical equivalent [SE] ≤-0.5 D), emmetropia (-0.5 D < SE < +0.5 D), and hyperopia (SE ≥+0.5 D), whereas the AL was divided into short (AL <22.5 mm), regular (22.5 ≤ AL <23.5 mm), and long (AL ≥23.5 mm). The refractive status and ocular biometric parameters were compared among different AL groups. Results: The mean AL of the PACG eyes was 22.53 ± 0.84 mm (range: 19.68-25.57 mm). The refractive status was significantly different among different AL groups (P < 0.001). Also, 92.6% of hyperopic PACG eyes showed AL <23.5 mm, and 19.0% of myopic PACG eyes showed AL ≥23.5 mm. The SE showed significant differences among different AL groups only in the hyperopic subjects (P = 0.012). The AL was significantly longer in myopic eyes (P < 0.001). The PACG eyes with longer AL exhibited lower keratometry, longer central anterior chamber depth and corneal diameter, and lens position and relative lens position closer to the anterior (P < 0.001). Conclusion: Axial hyperopia was common in PACG eyes, and axial myopia was not uncommon. Relatively anterior lens position could explain the occurrence of PACG in the eyes with long AL.


Asunto(s)
Glaucoma de Ángulo Cerrado , Hiperopía , Cristalino , Miopía , Humanos , Hiperopía/diagnóstico , Glaucoma de Ángulo Cerrado/diagnóstico , Refracción Ocular , Miopía/complicaciones , Miopía/diagnóstico , Córnea , Biometría , Cámara Anterior/diagnóstico por imagen
18.
Optom Vis Sci ; 100(5): 304-311, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-36951871

RESUMEN

SIGNIFICANCE: Highly hyperopic children are at greater risk for developing conditions such as strabismus, amblyopia, and early literacy and reading problems. High hyperopia is a common finding in infants in a pediatric medical practice, and early detection can be done effectively in that setting with tropicamide autorefraction. PURPOSE: This study aimed to evaluate the effectiveness of a pilot screening program to detect high hyperopia in 2-month-old infants in a pediatric medical practice in Columbus, Ohio. METHODS: Cycloplegic refractive error (1% tropicamide) was measured by retinoscopy and autorefraction with the Welch Allyn SureSight (Welch Allyn/Hillrom, Skaneateles Falls, NY) in 473 infants (55.4% female) who were undergoing their 2-month well-baby visit at their pediatrician's medical practice. Cycloplegic retinoscopy (1% cyclopentolate) was repeated at a subsequent visit in 35 infants with ≥+5.00 D hyperopia in the most hyperopic meridian during the screening. RESULTS: Twenty-eight infants (5.9%) had high hyperopia (spherical equivalent, ≥+5.00 D), and 61 (12.9%) had high hyperopia (≥+5.00 D in at least one meridian of at least one eye) by retinoscopy with 1% tropicamide. The mean ± standard deviation spherical equivalent tropicamide cycloplegic refractive error measured with retinoscopy was +2.54 ± 1.54 D (range, -3.25 to +7.00 D) and with SureSight was +2.29 ± 1.64 D (range, -2.90 to +7.53 D). Retinoscopy done using 1% cyclopentolate was 0.44 ± 0.54 D more hyperopic in spherical equivalent than with 1% tropicamide ( P < .001). CONCLUSIONS: High hyperopia was a common finding in 2-month-old infants in a pediatric medical setting that could be detected effectively by cycloplegic autorefraction using tropicamide. Greater cooperation between pediatric primary vision and medical care could lead to effective vision screenings designed to detect high hyperopia in infants.


Asunto(s)
Hiperopía , Errores de Refracción , Niño , Humanos , Lactante , Femenino , Masculino , Midriáticos , Hiperopía/diagnóstico , Ciclopentolato , Tropicamida , Proyectos Piloto , Errores de Refracción/diagnóstico , Refracción Ocular , Retinoscopía/métodos
19.
J Glaucoma ; 32(4): 257-264, 2023 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-36847699

RESUMEN

PRCIS: The risk of primary angle closure disease (PACD) rises rapidly with greater hyperopia while remaining relatively low for all degrees of myopia. Refractive error (RE) is useful for angle closure risk stratification in the absence of biometric data. PURPOSE: To assess the role of RE and anterior chamber depth (ACD) as risk factors in PACD. METHODS: Chinese American Eye Study participants received complete eye examinations including refraction, gonioscopy, amplitude-scan biometry, and anterior segment ocular coherence tomography imaging. PACD included primary angle closure suspect (≥3 quadrants of angle closure on gonioscopy) and primary angle closure/primary angle closure glaucoma (peripheral anterior synechiae or intraocular pressure >21 mm Hg). Logistic regression models were developed to assess associations between PACD and RE and/or ACD adjusted for sex and age. Locally weighted scatterplot smoothing curves were plotted to assess continuous relationships between variables. RESULTS: Three thousand nine hundred seventy eyes (3403 open angle and 567 PACD) were included. The risk of PACD increased with greater hyperopia [odds ratio (OR) = 1.41 per diopter (D); P < 0.001] and shallower ACD (OR = 1.75 per 0.1 mm; P < 0.001). Hyperopia (≥ + 0.5 D; OR = 5.03) and emmetropia (-0.5 D to +0.5 D; OR = 2.78) conferred a significantly higher risk of PACD compared with myopia (≤0.5 D). ACD (standardized regression coefficient = -0.54) was a 2.5-fold stronger predictor of PACD risk compared with RE (standardized regression coefficient = 0.22) when both variables were included in one multivariable model. The sensitivity and specificity of a 2.6 mm ACD cutoff for PACD were 77.5% and 83.2% and of a +2.0 D RE cutoff were 22.3% and 89.1%. CONCLUSION: The risk of PACD rises rapidly with greater hyperopia while remaining relatively low for all degrees of myopia. Although RE is a weaker predictor of PACD than ACD, it remains a useful metric to identify patients who would benefit from gonioscopy in the absence of biometric data.


Asunto(s)
Glaucoma de Ángulo Cerrado , Hiperopía , Miopía , Humanos , Cámara Anterior/diagnóstico por imagen , Segmento Anterior del Ojo/diagnóstico por imagen , Glaucoma de Ángulo Cerrado/diagnóstico , Gonioscopía , Hiperopía/diagnóstico , Presión Intraocular , Miopía/diagnóstico , Factores de Riesgo , Tomografía de Coherencia Óptica/métodos , Asiático
20.
J AAPOS ; 27(1): 24.e1-24.e7, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36642243

RESUMEN

PURPOSE: To evaluate the Spot Vision Screener according to updated 2021 AAPOS Vision Screening Committee guidelines for instrument-based pediatric vision screen validation. METHODS: As part of an IRB-approved ongoing prospective study, children were screened with the Spot prior to a complete examination. RESULTS: Spot screening was successful in 1,036 of 1,090 children (95%). Forty-eight percent of participants were referred for further screening using the Spot manufacturer guidelines, and 40% of all children were found to have a 2021 amblyopia risk factor or visually significant refractive error by gold standard examination. The Spot recommendation compared reasonably well to the 2021 criteria, with an overall sensitivity of 0.88 and a specificity of 0.78. Applying updated guidelines to the Spot for hyperopia, anisometropia, and astigmatism yielded moderate-to-poor sensitivity (0.27-0.77) but excellent specificity (>0.9). The area under the curve of the receiver operating characteristic analysis demonstrates overall good prediction performance for the Spot for each diagnosis-myopia, hyperopia, astigmatism, anisometropia (range, 0.87-0.97). Results of our study suggest increasing the instrument referral criterion for astigmatism from 1.5 D (manufacturer thresholds of the screener used in this study) to 2 D in older children. Decreasing the anisometropia cut-off from 1 D to 0.75 D would improve sensitivity from 0.59 to >0.8. CONCLUSIONS: In our study population, the overall predictive ability of the Spot is good, with a sensitivity of 0.88 and a specificity of 0.78. We recommend specific device refractive referral criteria to maximize screening effectiveness using the updated AAPOS guidelines.


Asunto(s)
Ambliopía , Anisometropía , Astigmatismo , Hiperopía , Errores de Refracción , Selección Visual , Niño , Humanos , Astigmatismo/diagnóstico , Anisometropía/diagnóstico , Hiperopía/diagnóstico , Sensibilidad y Especificidad , Estudios Prospectivos , Ambliopía/diagnóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...