Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27
Filtrar
1.
Sci Rep ; 14(1): 378, 2024 01 03.
Artículo en Inglés | MEDLINE | ID: mdl-38172327

RESUMEN

Sweat is an essential protection system for the body, but its failure can result in pathologic conditions, including several skin diseases, such as palmoplantar pustulosis (PPP). As reduced intraepidermal E-cadherin expression in skin lesions was confirmed in PPP skin lesions, a role for interleukin (IL)-1-rich sweat in PPP has been proposed, and IL-1 has been implicated in the altered E-cadherin expression observed in both cultured keratinocytes and mice epidermis. For further investigation, live imaging of sweat perspiration on a mouse toe-pad under two-photon excitation microscopy was performed using a novel fluorescent dye cocktail (which we named JSAC). Finally, intraepidermal vesicle formation which is the main cause of PPP pathogenesis was successfully induced using our "LASER-snipe" technique with JSAC. "LASER-snipe" is a type of laser ablation technique that uses two-photon absorption of fluorescent material to destroy a few acrosyringium cells at a pinpoint location in three-dimensional space of living tissue to cause eccrine sweat leakage. These observatory techniques and this mouse model may be useful not only in live imaging for physiological phenomena in vivo such as PPP pathomechanism investigation, but also for the field of functional physiological morphology.


Asunto(s)
Psoriasis , Piel , Animales , Ratones , Piel/metabolismo , Sudor/metabolismo , Psoriasis/metabolismo , Epidermis/metabolismo , Glándulas Ecrinas/metabolismo , Interleucina-1/metabolismo , Imagen Óptica/efectos adversos , Cadherinas/metabolismo
2.
Thyroid ; 34(1): 64-69, 2024 01.
Artículo en Inglés | MEDLINE | ID: mdl-37897089

RESUMEN

Background: The impact of near-infrared autofluorescence (NIRAF) imaging on postthyroidectomy hypocalcemia is controversial. As patients with Graves' disease are at increased risk, our aim was to compare postoperative parathyroid function in these patients undergoing total thyroidectomy (TT) with or without NIRAF imaging. Methods: This was a retrospective "before and after" study, comparing outcomes of patients who underwent TT without or with NIRAF imaging at a single center. Primary outcome was the incidence of temporary hypocalcemia and secondary outcomes, rates of incidental parathyroidectomy on final specimens and permanent hypocalcemia. Analyses were performed using Mann-Whitney U and chi-Square tests. Continuous data are expressed as median (interquartile range). Results: There were 85 patients in NIRAF and 100 patients in non-NIRAF group. Groups were comparable regarding age, gender, body-mass index, and thyroid weight. Number of parathyroid glands identified intraoperatively was 3 in both groups (p = 0.47). Intraoperative parathyroid implantation rate was 16.5% in NIRAF and 6% in non-NIRAF group (p = 0.02). Incidental parathyroidectomy rate on final pathology was 12.9% in NIRAF and 32% in non-NIRAF group (p = 0.002). The rates of temporary (11.7% vs. 16%) and permanent hypocalcemia (2.4% vs. 2%) were similar between the two groups, respectively (p = 0.66). Conclusion: To our knowledge, this is the first comparative study investigating the impact of NIRAF on postoperative parathyroid function after thyroidectomy for Graves' disease. The rate of incidental parathyroidectomy on final pathology was lower with use of NIRAF, without an impact on temporary or permanent hypocalcemia rates compared to conventional technique.


Asunto(s)
Enfermedad de Graves , Hipocalcemia , Humanos , Tiroidectomía/efectos adversos , Tiroidectomía/métodos , Hipocalcemia/etiología , Estudios Retrospectivos , Complicaciones Posoperatorias/etiología , Glándulas Paratiroides/diagnóstico por imagen , Glándulas Paratiroides/cirugía , Paratiroidectomía/métodos , Enfermedad de Graves/diagnóstico por imagen , Enfermedad de Graves/cirugía , Enfermedad de Graves/complicaciones , Imagen Óptica/efectos adversos , Imagen Óptica/métodos
3.
Pancreatology ; 24(1): 130-136, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38016861

RESUMEN

BACKGROUND: Laparoscopic duodenum-preserving pancreatic head resection (LDPPHR) is a surgical method used to treat benign and low-grade malignant pancreatic head tumors. This study aimed to determine the protective effect of common bile duct in LDPPHR using indocyanine green (ICG) fluorescence imaging. METHODS: A retrospective analysis of 30 patients treated with LDPPHR at the Second Affiliated Hospital of Nanchang University between January 2015 and November 2022 was performed. Patients were divided into two groups based on ICG use: ICG and non-ICG. RESULTS: Thirty patients received LDPPHR, 11 males and 19 females, and the age was 50.50 (M (IQR)) years (range: 19-76 years). LDPPHR was successfully performed in 27 (90 %) patients, LPD was performed in 1 (3 %) patient, and laparotomy conversion was performed in 2 (7 %) patients. One patient (3 %) died 21 days after surgery. The incidence of intraoperative bile duct injury in the ICG group was lower than that in the non-ICG group (10 % vs 60 %, P = 0.009), and the operation time in the ICG group was shorter than that in the non-ICG group (311.9 ± 14.97 vs 338.05 ± 18.75 min, P < 0.05). Postoperative pancreatic fistula occurred in 16 patients (53 %), including 10 with biochemical leakage (62.5 %), four with grade B (25 %), and two with grade C (12.5 %). Postoperative bile leakage occurred in four patients (13 %). CONCLUSIONS: The ICG fluorescence imaging technology in LDPPHR helps protect the integrity of the common bile duct and reduce the occurrence of intraoperative bile duct injury, postoperative bile leakage, and bile duct stenosis.


Asunto(s)
Enfermedades de los Conductos Biliares , Laparoscopía , Masculino , Femenino , Humanos , Verde de Indocianina , Estudios Retrospectivos , Laparoscopía/métodos , Enfermedades de los Conductos Biliares/etiología , Imagen Óptica/efectos adversos , Imagen Óptica/métodos , Duodeno/diagnóstico por imagen , Duodeno/cirugía
4.
Respir Med ; 207: 107114, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36608860

RESUMEN

BACKGROUND: Medical thoracoscopy (MT) does not always provide a conclusive diagnosis of pleural diseases because the endoscopic appearance of pleural diseases can be misleading. Autofluorescence imaging (AFI) is an effective assistive diagnostic tool. However, its clinical application for pleural disease remains controversial. OBJECTIVES: This prospective study evaluated the clinical usefulness of AFI-assisted MT for diagnosis of malignant pleural diseases. METHODS: Patients with unexplained pleural effusion admitted to our clinics between December 2018 and September 2021 were enrolled. We performed white-light thoracoscopy (WLT) first, and then AFI, during MT. Images of endoscopic real-time lesions were recorded under both modes. Pleural biopsy specimens were analyzed pathologically. Between-groups differences in diagnostic sensitivity, specificity, positive-predictive value (PPV), and negative-predictive value (NPV) were assessed using 95% confidence intervals (CI). Receiver operating characteristic curves and decision curve analyses were employed to analyze the diagnostic efficiency of these two modes. RESULTS: Of 126 eligible patients, 73 cases were diagnosed with malignant pleural disease. A total of 1292 biopsy specimens from 492 pleural sites were examined for pathological changes. The diagnostic sensitivity, PPV, and NPV of AFI were 99.7%, 58.2%, and 99.2%, respectively. AFI was significantly superior to WLT, which had a sensitivity of 79.7%, PPV of 50.7%, and NPV of 62.8%. Subgroup analysis showed that the AFI type III pattern was significantly more specific for pleural malignant disease than that of WLT. CONCLUSIONS: AFI could further improve the diagnostic efficacy of MT by providing better visualization, convenience, and safety.


Asunto(s)
Neoplasias , Enfermedades Pleurales , Derrame Pleural , Humanos , Estudios Prospectivos , Enfermedades Pleurales/patología , Pleura/diagnóstico por imagen , Pleura/patología , Derrame Pleural/etiología , Toracoscopía , Imagen Óptica/efectos adversos , Síndrome
5.
Int J Colorectal Dis ; 38(1): 7, 2023 Jan 10.
Artículo en Inglés | MEDLINE | ID: mdl-36625972

RESUMEN

PURPOSE: The purpose of this study was to clarify the usefulness of indocyanine green fluorescence imaging (ICG-FI) in the assessment of intestinal vascular perfusion in patients who receive intracorporeal anastomosis (IA) in colon cancer surgery. METHODS: This was a single-center, retrospective study using propensity score matching. We compared the surgical outcomes of colon cancer patients who underwent laparoscopic colonic resection with IA or external anastomosis (EA) with the intraoperative evaluation of anastomotic perfusion using ICG-FI from January 2019 to July 2021. The detection rate of poor anastomotic perfusion by ICG-FI was examined. RESULTS: A total of 223 patients were enrolled. After matching, 69 patients each were classified into the IA and EA groups. There were no significant differences in age, sex, body mass index, tumor localization, or progression between the two groups. The operation time was similar (172 min vs. 171 min, p = 0.62) and the amount of bleeding was significantly lower (0 ml vs. 2 ml, p = 0.0023) in the IA group. The complication rates (grade ≥ 2) of the two groups were similar (14.5% vs. 11.6%, p = 0.59). ICG-FI identified four patients (5.8%) with poor anastomotic perfusion in the IA group, but none in the EA group (p = 0.046). All four patients with poor perfusion in the IA group underwent additional resection; none of these patients developed postoperative complications. CONCLUSION: Poor anastomotic perfusion was detected in 5.8% of cases who underwent laparoscopic colon cancer surgery with IA. ICG-FI is useful for evaluating anastomotic perfusion in IA in order to prevent AL.


Asunto(s)
Neoplasias del Colon , Neoplasias Colorrectales , Laparoscopía , Humanos , Verde de Indocianina , Neoplasias Colorrectales/cirugía , Estudios Retrospectivos , Fuga Anastomótica/etiología , Neoplasias del Colon/diagnóstico por imagen , Neoplasias del Colon/cirugía , Neoplasias del Colon/complicaciones , Anastomosis Quirúrgica/efectos adversos , Laparoscopía/efectos adversos , Perfusión/efectos adversos , Imagen Óptica/efectos adversos , Imagen Óptica/métodos
6.
JAMA Otolaryngol Head Neck Surg ; 149(3): 253-260, 2023 03 01.
Artículo en Inglés | MEDLINE | ID: mdl-36633855

RESUMEN

Importance: Identification and preservation of parathyroid glands (PGs) remain challenging despite advances in surgical techniques. Considerable morbidity and even mortality result from hypoparathyroidism caused by devascularization or inadvertent removal of PGs. Emerging imaging technologies hold promise to improve identification and preservation of PGs during thyroid surgery. Observation: This narrative review (1) comprehensively reviews PG identification and vascular assessment using near-infrared autofluorescence (NIRAF)-both label free and in combination with indocyanine green-based on a comprehensive literature review and (2) offers a manual for possible implementation these emerging technologies in thyroid surgery. Conclusions and Relevance: Emerging technologies hold promise to improve PG identification and preservation during thyroidectomy. Future research should address variables affecting the degree of fluorescence in NIRAF, standardization of signal quantification, definitions and standardization of parameters of indocyanine green injection that correlate with postoperative PG function, the financial effect of these emerging technologies on near-term and longer-term costs, the adoption learning curve and effect on surgical training, and long-term outcomes of key quality metrics in adequately powered randomized clinical trials evaluating PG preservation.


Asunto(s)
Hipoparatiroidismo , Glándulas Paratiroides , Humanos , Glándulas Paratiroides/diagnóstico por imagen , Glándulas Paratiroides/cirugía , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/cirugía , Verde de Indocianina , Imagen Óptica/efectos adversos , Imagen Óptica/métodos , Tiroidectomía/métodos , Hipoparatiroidismo/etiología
7.
Dis Esophagus ; 36(2)2023 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35849094

RESUMEN

Chylothorax is a serious complication after esophagectomy and there are unmet needs for new intraoperative navigation tools to reduce its incidence. The aim of this study is to explore the feasibility and effectiveness of near-infrared fluorescence imaging (NIR-FI) with indocyanine green (ICG) to identify thoracic ducts (TDs) and chyle leakage during video-assisted thoracoscopic esophagectomy. We recruited 41 patients who underwent thoraco-laparoscopic minimally invasive esophagectomy (MIE) for esophageal cancer in this prospective, open-label, single-arm clinical trial. ICG was injected into the right inguinal region before operations, after which TD anatomy and potential chyle leakage were checked under the near-infrared fluorescence intraoperatively. In 38 of 41 patients (92.7%) using NIR-FI, TDs were visible in high contrast. The mean signal-to-background ratio (SBR) value of all fluorescent TDs was 3.05 ± 1.56. Fluorescence imaging of TDs could be detected 0.5 hours after ICG injection and last up to 3 hours with an acceptable SBR value. The optimal observation time window is from about 1 to 2 hours after ICG injection. Under the guidance of real-time NIR-FI, three patients were found to have chylous leakage and the selective TD ligations were performed intraoperatively. No patient had postoperative chylothorax. NIR-FI with ICG can provide highly sensitive and real-time assessment of TDs as well as determine the source of chyle leakage, which might help reduce TD injury and direct selective TD ligation. It could be a promising navigation tool to reduce the incidence of chylothorax after minimally invasive esophagectomy.


Asunto(s)
Quilotórax , Neoplasias Esofágicas , Humanos , Quilotórax/diagnóstico por imagen , Quilotórax/etiología , Quilotórax/cirugía , Neoplasias Esofágicas/diagnóstico por imagen , Neoplasias Esofágicas/cirugía , Neoplasias Esofágicas/complicaciones , Esofagectomía/efectos adversos , Esofagectomía/métodos , Verde de Indocianina , Imagen Óptica/efectos adversos , Complicaciones Posoperatorias/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Estudios Prospectivos , Conducto Torácico/diagnóstico por imagen , Conducto Torácico/cirugía
8.
Transl Vis Sci Technol ; 11(10): 23, 2022 10 03.
Artículo en Inglés | MEDLINE | ID: mdl-36239964

RESUMEN

Purpose: The purpose of this study was to investigate quantitative autofluorescence (qAF8) in patients with and without early or intermediate age-related macular degeneration (AMD); to determine the impact of the aged crystalline lens and posterior capsular opacification (PCO). Methods: In phakic and pseudophakic eyes ≥60 years, AMD status was determined by the Beckman system. PCO presence and severity was extracted from clinical records. qAF8 was calculated using custom FIJI plugins. Differences in qAF8, stratified by lens status, PCO severity, and AMD status, were analyzed using generalized estimating equations. Results: In 210 eyes of 115 individuals (mean age = 75.7 ± 6.6 years), qAF8 was lower in intermediate AMD compared to early AMD (P = 0.05). qAF8 did not differ between phakic and pseudophakic eyes (P = 0.8909). In phakic (n = 83) and pseudophakic (n = 127) eyes considered separately, qAF8 did not differ by AMD status (P = 0.0936 and 0.3494, respectively). Qualitative review of qAF images in phakic eyes illustrated high variability. In pseudophakic eyes, qAF8 did not differ with PCO present versus absent (54.5% vs. 45.5%). Review of implanted intraocular lenses (IOLs) revealed that 43.9% were blue-filter IOLs. Conclusions: qAF8 was not associated with AMD status, up to intermediate AMD, considering only pseudophakic eyes to avoid noisy images in phakic eyes. In pseudophakic eyes, qAF8 was not affected by PCO. Because blue-filter IOLs may reduce levels of exciting light for qAF8, future studies investigating qAF in eyes with different IOL types are needed. Translational Relevance: To reduce variability in observational studies and clinical trials requiring qAF8, pseudophakic participants without blue-filter IOLs or advanced PCO should be preferentially enrolled.


Asunto(s)
Opacificación Capsular , Cristalino , Degeneración Macular , Anciano , Anciano de 80 o más Años , Envejecimiento , Opacificación Capsular/diagnóstico por imagen , Opacificación Capsular/etiología , Humanos , Degeneración Macular/complicaciones , Imagen Óptica/efectos adversos
9.
BMC Gastroenterol ; 22(1): 373, 2022 Aug 05.
Artículo en Inglés | MEDLINE | ID: mdl-35931985

RESUMEN

Revision surgery for the complications after repair of esophageal atresia is often complex because of previous surgeries and chest infections and thus requires surgical expertise. This study describes surgical experiences with the use of indocyanine green (ICG) fluorescence imaging localization-assisted thoracoscopy during revision surgery, including recurrent tracheoesophageal fistula (rTEF) (8 cases, one of which was esophageal-pulmonary fistula) and delayed esophageal closure (1 case). We performed fistula repair and esophageal reconstruction according to the indications of ICG. The application of this method avoids the excessive trauma caused by freeing the trachea and esophagus. Contrast imaging taken one week and one month after surgery indicated no spillover of the contrast agent from the esophagus, except in 1 case. Indocyanine green fluorescence imaging localization-assisted thoracoscopy is worth promoting for revision surgery after esophageal atresia repair.


Asunto(s)
Atresia Esofágica , Fístula Traqueoesofágica , Atresia Esofágica/complicaciones , Atresia Esofágica/diagnóstico por imagen , Atresia Esofágica/cirugía , Humanos , Verde de Indocianina , Imagen Óptica/efectos adversos , Reoperación/efectos adversos , Estudios Retrospectivos , Toracoscopía/efectos adversos , Toracoscopía/métodos , Fístula Traqueoesofágica/diagnóstico por imagen , Fístula Traqueoesofágica/etiología , Fístula Traqueoesofágica/cirugía
10.
Front Endocrinol (Lausanne) ; 13: 897797, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35784544

RESUMEN

Background and objectives: Accurate identification and evaluation of the parathyroid glands (PGs) intraoperatively is critical to reduce the incidence of postoperative hypoparathyroidism after total thyroidectomy. Near-infrared fluorescence imaging (NIFI), including the autofluorescence (AF) and indocyanine green fluorescence (ICGF) imaging, is a promising technique to protect PGs. This study aimed to assess whether the combined use of AF and ICGF could reduce the incidence of postoperative hypoparathyroidism and improve the identification and evaluation of PGs during total thyroidectomy. Methods: This randomized controlled trial enrolled 180 patients who were randomized into two groups and underwent total thyroidectomy with unilateral or bilateral central lymph node dissection. In the control group, the PGs were identified and evaluated by the naked eye. In the NIFI group, AF was used to identify the PGs and ICGF was applied to assess the blood perfusion of the PGs in situ. The primary outcome was the incidence of postoperative hypoparathyroidism. The secondary outcomes included the number of identified PGs, autotransplanted PGs, and known preserved PGs in situ. Results: The incidence of postoperative transient hypoparathyroidism was significantly lower in the NIFI group than in the control group (27.8% vs. 43.3%, P = 0.029). More PGs were identified in the NIFI group than in the control group (3.6 ± 0.5 vs. 3.2 ± 0.4, P < 0.001). No significant difference was observed in the number of autotransplanted PGs between the two groups (P = 0.134). Compared with the control group, a greater number of known PGs were preserved in situ in the NIFI group (1.3 ± 0.6 vs. 1.0 ± 0.5, P < 0.001). In the NIFI group, only 4.5% of the patients with at least one well-perfused PG (ICG score of 2) developed postoperative hypoparathyroidism, which was significantly lower than that of the control group (34.6%, P < 0.001). Conclusion: Combined use of AF and ICGF during total thyroidectomy reduces the risk of transient postoperative hypoparathyroidism, enhances the ability to identify and preserve PGs, and improves the accuracy of evaluating the perfusion of PGs during surgery. Clinical Trial Registration: Chinese Clinical Trial Register (www.chictr.org.cn), identifier ChiCTR2100045320. Registered on April 12, 2021.


Asunto(s)
Hipoparatiroidismo , Glándulas Paratiroides , Humanos , Hipoparatiroidismo/diagnóstico , Hipoparatiroidismo/epidemiología , Hipoparatiroidismo/etiología , Verde de Indocianina , Imagen Óptica/efectos adversos , Imagen Óptica/métodos , Glándulas Paratiroides/diagnóstico por imagen , Tiroidectomía/efectos adversos , Tiroidectomía/métodos
11.
J Invest Surg ; 35(9): 1723-1732, 2022 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-35786292

RESUMEN

OBJECTIVE: This meta-analysis aimed to assess the position of near-infrared autofluorescence (NIRAF) imaging in the recognition and protection of the parathyroid gland (PG) during thyroidectomy. METHODS: The PubMed, MEDLINE, EMBASE, Web of Science, and Cochrane Library databases were searched up to June 2021. The primary outcome was to evaluate the rates of postoperative hypocalcemia, inadvertent PG resection, and autotransplantation of PG when adopting NIRAF imaging compared with standard naked-eye (N-E) surgery. RESULTS: Eight studies with 2,889 patients were enrolled in the analysis. Our analysis showed that the incidence of transient hypocalcemia was 7.11% (60/844) in the NIRAF group and 22.40% (458/2045) in the N-E group (p < 0.0001) and the rate of transient hypoparathyroidism was 28.31% (126/445) and 33.36% (496/1487) in the NIRAF and N-E groups (p = 0.0008). The rate of inadvertent resection of PGs was 7.65% (55/719) in the NIRAF group and 14.39% (132/917) in the N-E group (p < 0.0001). No significant difference was observed in other indexes including the pooled proportion of permanent hypocalcemia and rate of PG autotransplantation. CONCLUSIONS: The application of NIRAF imaging in thyroidectomy can help lower the incidence of inadvertent PG resection and reduce the risk of postoperative hypocalcemia and hypoparathyroidism compared with N-E recognition.


Asunto(s)
Hipocalcemia , Hipoparatiroidismo , Humanos , Hipocalcemia/epidemiología , Hipocalcemia/etiología , Hipocalcemia/prevención & control , Hipoparatiroidismo/epidemiología , Hipoparatiroidismo/etiología , Hipoparatiroidismo/prevención & control , Imagen Óptica/efectos adversos , Imagen Óptica/métodos , Glándulas Paratiroides/cirugía , Glándulas Paratiroides/trasplante , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/prevención & control , Glándula Tiroides/diagnóstico por imagen , Glándula Tiroides/cirugía , Tiroidectomía/efectos adversos , Tiroidectomía/métodos
12.
Microcirculation ; 29(6-7): e12768, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35593520

RESUMEN

OBJECTIVE: Necrotizing enterocolitis (NEC) is the most prevalent gastrointestinal emergency in premature infants and is characterized by a dysfunctional gut microcirculation. Therefore, there is a dire need for in vivo methods to characterize NEC-induced changes in the structure and function of the gut microcirculation, that is, its vascular phenotype. Since in vivo gut imaging methods are often slow and employ a single-contrast mechanism, we developed a rapid multicontrast imaging technique and a novel analyses pipeline for phenotyping the gut microcirculation. METHODS: Using an experimental NEC model, we acquired in vivo images of the gut microvasculature and blood flow over a 5000 × 7000 µm2 field of view at 5 µm resolution via the following two endogenous contrast mechanisms: intrinsic optical signals and laser speckles. Next, we transformed intestinal images into rectilinear "flat maps," and delineated 1A/V gut microvessels and their perfusion territories as "intestinal vascular units" (IVUs). Employing IVUs, we quantified and visualized NEC-induced changes to the gut vascular phenotype. RESULTS: In vivo imaging required 60-100 s per animal. Relative to the healthy gut, NEC intestines showed a significant overall decrease (i.e. 64-72%) in perfusion, accompanied by vasoconstriction (i.e. 9-12%) and a reduction in perfusion entropy (19%)within sections of the vascular bed. CONCLUSIONS: Multicontrast imaging coupled with IVU-based in vivo vascular phenotyping is a powerful new tool for elucidating NEC pathogenesis.


Asunto(s)
Enterocolitis Necrotizante , Humanos , Recién Nacido , Animales , Enterocolitis Necrotizante/diagnóstico por imagen , Enterocolitis Necrotizante/etiología , Enterocolitis Necrotizante/patología , Microvasos , Microcirculación/fisiología , Recien Nacido Prematuro , Imagen Óptica/efectos adversos
13.
Artículo en Chino | MEDLINE | ID: mdl-35483695

RESUMEN

The main causes of hypoparathyroidism are unintentional parathyroidectomy and/or impaired blood supply. Therefore, accurate identification and preservation of parathyroid glands in situ during thyroid or parathyroid surgery has become one of the problems that plague endocrine surgeons. In recent years, near-infrared autofluorescence imaging technology has gradually attracted more and more attention from surgeons because of its simplicity, safety, accuracy, real-time, no-contrast agent, and non-invasiveness. This article reviews the development history, clinical application, and application prospects of the parathyroid gland autofluorescence imaging technology in recent years.


Asunto(s)
Hipoparatiroidismo , Glándulas Paratiroides , Humanos , Hipoparatiroidismo/etiología , Hipoparatiroidismo/cirugía , Imagen Óptica/efectos adversos , Imagen Óptica/métodos , Glándulas Paratiroides/diagnóstico por imagen , Paratiroidectomía/métodos , Tiroidectomía/métodos
14.
Dis Colon Rectum ; 64(12): 1542-1550, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-33661231

RESUMEN

BACKGROUND: Recent studies have clarified that near-infrared observation using indocyanine green has the advantage of evaluating perfusion of the anastomotic site, especially in rectal cancer surgery, resulting in a reduction in anastomotic leak. OBJECTIVE: The aim of this study was to evaluate the efficacy of near-infrared observation for reducing the anastomotic leak after stapled side-to-side anastomosis in colon cancer surgery. DESIGN: This was a retrospective propensity score case-matched study. SETTINGS: The study was conducted at 3 institutions in the Yokohama Clinical Oncology Group. PATIENTS: From January 2011 to December 2019, patients who underwent colon cancer surgery with stapled side-to-side anastomosis were included. MAIN OUTCOME MEASURES: The main outcome was the percentage of anastomotic leak within 30 days after surgery. RESULTS: A total of 1034 patients were collected. There were 532 patients who underwent near-infrared observation and 502 who did not. A total of 370 patients were matched to the near-infrared and non-near-infrared groups. In the near-infrared group, 12 patients (3.2%) were judged to have poor perfusion (4 patients) and no perfusion (8 patients), so the planned transection point was changed. There were no cases of anastomotic leak among these 12 patients. The anastomotic leak rates were 3.5% (13/370) in the non-near-infrared group and 0.8% (3/370) in the near-infrared group. The anastomotic leak and reoperation rates were significantly lower in the near-infrared group than in the non-near-infrared group (OR, 0.224; 95% CI, 0.063-0.794, p = 0.001; OR, 0.348; 95% CI, 0.124-0.977, p = 0.036). LIMITATIONS: Although we reduced selection bias by performing propensity score matching, this was a retrospective study and was not randomized. CONCLUSION: This large-scale case-matched study showed that assessing perfusion by near-infrared observation significantly reduced the anastomotic leak and reoperation rates after stapled side-to-side anastomosis in colon cancer surgery and may be better suited to colo-colonic anastomosis. Video Abstract at http://links.lww.com/DCR/B513.Japanese Clinical Trials Registry: UMIN-CTR000039977. EVALUACIN DEL EFECTO DE LA OBSERVACIN INTRAOPERATORIA CON INFRARROJO CERCANO SOBRE LA FUGA ANASTOMTICA DESPUS DE UNA ANASTOMOSIS LATEROLATERAL CON ENGRAPADORA EN LA CIRUGA DE CNCER DE COLON MEDIANTE EL EMPAREJAMIENTO POR PUNTAJES DE PROPENSIN: ANTECEDENTES:Estudios recientes han aclarado que la observación con infrarrojo cercano con verde de indocianina tiene la ventaja de evaluar la perfusión del sitio anastomótico, especialmente en la cirugía de cáncer de recto, lo que resulta en una reducción de la fuga anastomótica.OBJETIVO:El objetivo de este estudio fue evaluar la eficacia de la observación con infrarrojo cercano para reducir la fuga anastomótica después de una anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon.DISEÑO:Este fue un estudio retrospectivo emparejado con puntaje de propensión.AJUSTE:El estudio se llevó a cabo en tres instituciones del Grupo de Oncología Clínica de Yokohama.PACIENTES:Desde enero de 2011 hasta diciembre de 2019, se incluyeron pacientes que se sometieron a cirugía de cáncer de colon con anastomosis latero-lateral con engrapadora.PRINCIPALES MEDIDAS DE RESULTADO:El resultado principal fue el porcentaje de fuga anastomótica dentro de los 30 días posteriores a la cirugía.RESULTADOS:Se recogió un total de 1034 pacientes. Hubo 532 pacientes que se sometieron a observación con infrarrojo cercano y 502 que no. Un total de 370 pacientes fueron emparejados con los grupos de infrarrojo cercano y no infrarrojo cercano. En el grupo de infrarrojo cercano, se consideró que 12 casos (3,2%) tenían mala perfusión (4 casos) y ninguna perfusión (8 casos), por lo que se cambió el punto de transección planificado. No hubo casos de fuga anastomótica entre estos 12 casos. Las tasas de fuga anastomótica fueron del 3,5% (13/370) en el grupo sin infrarrojo cercano y del 0,8% (3/370) en el grupo con infrarrojo cercano. Las tasas de fuga anastomótica y de reintervención fueron significativamente menores en el grupo con infrarrojo cercano que en el grupo sin infrarrojo cercano (razón de posibilidades 0,224, intervalo de confianza del 95% 0,063-0,794, p = 0,001; razón de posibilidades 0,348, intervalo de confianza del 95% 0,124 -0,977, p = 0,036, respectivamente).LIMITACIONES:Aunque se redujo el sesgo de selección al realizar el emparejamiento por puntaje de propensión, este fue un estudio retrospectivo y no fue aleatorio.CONCLUSIÓN:Este estudio de casos emparejados a gran escala demostró que la evaluación de la perfusión mediante la observación con infrarrojo cercano redujo significativamente la fuga anastomótica y las tasas de reintervención después de la anastomosis latero-lateral con engrapadora en la cirugía de cáncer de colon y puede ser más adecuada para la anastomosis colo-colónica. Consulte Video Resumen en http://links.lww.com/DCR/B513.Registro japonés de ensayos clínicos: UMIN-CTR000039977.


Asunto(s)
Anastomosis Quirúrgica/efectos adversos , Fuga Anastomótica/diagnóstico por imagen , Neoplasias del Colon/cirugía , Imagen Óptica/efectos adversos , Anciano , Anciano de 80 o más Años , Fuga Anastomótica/epidemiología , Fuga Anastomótica/prevención & control , Estudios de Casos y Controles , Femenino , Humanos , Verde de Indocianina/administración & dosificación , Verde de Indocianina/metabolismo , Cuidados Intraoperatorios/instrumentación , Masculino , Imagen Óptica/métodos , Imagen de Perfusión/instrumentación , Puntaje de Propensión , Reoperación/estadística & datos numéricos , Estudios Retrospectivos , Suturas/efectos adversos
15.
J Surg Res ; 259: 39-46, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33279843

RESUMEN

BACKGROUND: We previously reported useful methods that can be implemented to identify intersegmental boundary lines (IBLs) by using an intravenous indocyanine green (ICG) fluorescence imaging system (ICG-FS) during a thoracoscopic anatomical segmentectomy (TAS). The aim of this study was to evaluate the recently released third-generation ICG-FS that features an emphasizing xenon-light source for IBL identification. METHODS: We prospectively studied cases involving 106 consecutive patients who underwent TAS. Intraoperatively, we used the third-generation ICG-FS, the conventional ICG methods (CIM) emphasizing xenon-light (CIM-X), and the spectra-A method (SAM) emphasizing xenon-light (SAM-X), for IBL identification. Furthermore, 16 of the 106 patients (15%) could be simultaneously evaluated using old-generation ICG-FSs, CIM, and SAM. All images were completely quantified for illuminance and for three colors, red, green, and blue. RESULTS: IBLs were successfully identified in all the patients (100%) with no adverse events. The SAM-X significantly increased the illuminance, especially in the resecting segments, compared to the CIM (39.0 versus 22.2, P < 0.01) and SAM (39.0 versus 29.3, P < 0.01), with enhanced red color compared to the CIM (33.1 versus 21.9, P < 0.01) and SAM (33.1 versus 14.0, P < 0.01). Furthermore, the SAM-X significantly increased the illuminance contrast compared to the CIM-X (34.1 versus 15.3, P < 0.01). CONCLUSIONS: The present study suggests that the SAM-X potentially provided images with the highest visibility and colorfulness compared to the older generation ICG-FSs or CIM-X. Secure IBL identification can be more easily and safely performed using the SAM-X.


Asunto(s)
Neoplasias Pulmonares/cirugía , Pulmón/diagnóstico por imagen , Imagen Óptica/métodos , Neumonectomía/métodos , Cirugía Torácica Asistida por Video/métodos , Administración Intravenosa , Adulto , Anciano , Anciano de 80 o más Años , Femenino , Colorantes Fluorescentes/administración & dosificación , Humanos , Verde de Indocianina/administración & dosificación , Luz , Pulmón/irrigación sanguínea , Pulmón/cirugía , Masculino , Persona de Mediana Edad , Imagen Óptica/efectos adversos , Imagen Óptica/instrumentación , Neumonectomía/efectos adversos , Neumonectomía/instrumentación , Cirugía Torácica Asistida por Video/efectos adversos , Cirugía Torácica Asistida por Video/instrumentación , Xenón
16.
Front Immunol ; 11: 575816, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-33123158

RESUMEN

Nanotechnology is widely used in the fields of biology and medicine. Some special nanoparticles with good biocompatibility, hydrophilicity, and photostability can be used as ideal systems for biomedical imaging in early diagnosis and treatment of diseases. Among them, aggregation-induced emission materials are new antiaggregation-caused quenching nano-imaging materials, which have advantages in biocompatibility, imaging contrast, and light stability. Meanwhile, heterogeneity of nanoparticles may cause various adverse immune reactions. In response to the above problems, many researchers have modified nano-materials to be multifunctional nano-composites, aiming at combining diagnosis and treatment with simultaneous imaging and targeted therapy and additionally avoiding immune reactions, which is of great potential in imaging-guided therapy. This review discusses the application of aggregation-induced emission materials, and other nano-imaging materials are also mentioned. We hope to provide new ideas and methods for the imaging of nano-materials in diagnosis and treatment.


Asunto(s)
Colorantes Fluorescentes/efectos adversos , Enfermedades del Sistema Inmune/inducido químicamente , Sistema Inmunológico/efectos de los fármacos , Nanopartículas/efectos adversos , Imagen Óptica , Nanomedicina Teranóstica , Animales , Humanos , Sistema Inmunológico/inmunología , Sistema Inmunológico/metabolismo , Enfermedades del Sistema Inmune/inmunología , Enfermedades del Sistema Inmune/metabolismo , Imagen Óptica/efectos adversos , Valor Predictivo de las Pruebas , Medición de Riesgo , Factores de Riesgo
17.
Clin Cancer Res ; 26(15): 3990-3998, 2020 08 01.
Artículo en Inglés | MEDLINE | ID: mdl-32345649

RESUMEN

PURPOSE: Incomplete oncologic resections and damage to vital structures during colorectal cancer surgery increases morbidity and mortality. Moreover, neoadjuvant chemoradiotherapy has become the standard treatment modality for locally advanced rectal cancer, where subsequent downstaging can make identification of the primary tumor more challenging during surgery. Near-infrared (NIR) fluorescence imaging can aid surgeons by providing real-time visualization of tumors and vital structures during surgery. EXPERIMENTAL DESIGN: We present the first-in-human clinical experience of a novel NIR fluorescent peptide, cRGD-ZW800-1, for the detection of colon cancer. cRGD-ZW800-1 was engineered to have an overall zwitterionic chemical structure and neutral charge to lower nonspecific uptake and thus background fluorescent signal. We performed a phase I study in 11 healthy volunteer as well as a phase II feasibility study in 12 patients undergoing an elective colon resection, assessing 0.005, 0.015, and 0.05 mg/kg cRGD-ZW800-1 for the intraoperative visualization of colon cancer. RESULTS: cRGD-ZW800-1 appears safe, and exhibited rapid elimination into urine after a single low intravenous dose. Minimal invasive intraoperative visualization of colon cancer through full-thickness bowel wall was possible after an intravenous bolus injection of 0.05 mg/kg at least 2 hours prior to surgery. Longer intervals between injection and imaging improved the tumor-to-background ratio. CONCLUSIONS: cRGD-ZW800-1 enabled fluorescence imaging of colon cancer in both open and minimal invasive surgeries. Further development of cRGD-ZW800-1 for widespread use in cancer surgery may be warranted given the ubiquitous overexpression of various integrins on different types of tumors and their vasculature.


Asunto(s)
Carcinoma/diagnóstico , Colon/diagnóstico por imagen , Neoplasias del Colon/diagnóstico , Colorantes Fluorescentes/administración & dosificación , Imagen Óptica/métodos , Anciano , Anciano de 80 o más Años , Animales , Carcinoma/patología , Carcinoma/terapia , Quimioradioterapia Adyuvante , Colectomía/métodos , Colon/patología , Colon/cirugía , Neoplasias del Colon/patología , Neoplasias del Colon/terapia , Estudios de Factibilidad , Femenino , Colorantes Fluorescentes/efectos adversos , Colorantes Fluorescentes/química , Colorantes Fluorescentes/farmacocinética , Voluntarios Sanos , Humanos , Integrinas/metabolismo , Masculino , Ratones , Persona de Mediana Edad , Terapia Neoadyuvante , Imagen Óptica/efectos adversos , Péptidos Cíclicos/administración & dosificación , Péptidos Cíclicos/efectos adversos , Péptidos Cíclicos/química , Péptidos Cíclicos/farmacocinética , Compuestos de Amonio Cuaternario/administración & dosificación , Compuestos de Amonio Cuaternario/efectos adversos , Compuestos de Amonio Cuaternario/química , Compuestos de Amonio Cuaternario/farmacocinética , Ratas , Espectroscopía Infrarroja Corta/métodos , Ácidos Sulfónicos/administración & dosificación , Ácidos Sulfónicos/efectos adversos , Ácidos Sulfónicos/química , Ácidos Sulfónicos/farmacocinética , Pruebas de Toxicidad Aguda
18.
BMC Cancer ; 19(1): 939, 2019 Oct 11.
Artículo en Inglés | MEDLINE | ID: mdl-31604469

RESUMEN

BACKGROUND: This preliminary study aimed to examine the feasibility of sentinel lymph node biopsy (SLNB) using contrast-enhanced ultrasound (CEUS) vs. indocyanine green fluorescence (ICG), combined with blue dye in patients with breast cancer. METHODS: This was a retrospective study of consecutive female patients with invasive stage I-III (based on pre-operative physical examination and imaging) primary breast cancer at the Peking Union Medical College Hospital between 01/2013 and 01/2015 who underwent preoperative SLNB by ICG + blue dye or CEUS + blue dye. The numbers of detected SLNs, detection rates, and recurrence-free survival (RFS) rates were compared between the two groups. RESULTS: A total of 443 patients were included. The detection rates of SLNs in the CEUS + blue dye and ICG + blue dye groups were 98.4 and 98.1%, respectively (P = 0.814). The average numbers of SLNs detected per patient showed no significant difference between the two groups (3.06 ± 1.33 and 3.12 ± 1.31 in the CEUS + blue dye and ICG + blue dye groups, respectively; P = 0.659). After a median follow-up of 46 months, five patients in the CEUS + blue dye group and 15 in the ICG + blue dye group had recurrence. RFS rates showed no significant difference (P = 0.55). CONCLUSION: This preliminary study suggests that CEUS + blue dye and ICG + blue dye are both feasible for SLN detection in breast cancer.


Asunto(s)
Neoplasias de la Mama/patología , Colorantes , Verde de Indocianina , Metástasis Linfática/diagnóstico por imagen , Azul de Metileno , Imagen Óptica/métodos , Biopsia del Ganglio Linfático Centinela/métodos , Ultrasonografía Mamaria/métodos , Adulto , Anciano , Axila , Supervivencia sin Enfermedad , Estudios de Factibilidad , Femenino , Estudios de Seguimiento , Humanos , Persona de Mediana Edad , Imagen Óptica/efectos adversos , Estudios Retrospectivos , Ganglio Linfático Centinela/patología , Ultrasonografía Mamaria/efectos adversos
19.
Breast Cancer ; 26(1): 1-10, 2019 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-29961238

RESUMEN

In the past decades, breast surgeons have changed the clinical practice in the surgical treatment of breast cancer, by performing sentinel lymph node biopsy (SLNB) instead of performing axillary lymph node dissection (ALND) in axillary lymph node clinically negative breast cancer patients. ALND can also be avoided in SLN-positive patients who meet the Z-0011 criteria. However, the postoperative complications of SLNB and ALND, such as the secondary upper extremity lymphedema, are common and need effective solutions to prevent as soon as possible. The axillary reverse mapping (ARM) technique has been developed to map and preserve arm lymphatic drainage during ALND and/or SLNB, thereby minimizing arm lymphedema. However, the success of ARM in reducing lymphedema has not been exactly determined. If ARM can be confirmed to be both effective and oncologically safe in preventing lymphedema, this technique should be recommended in the management of breast cancer treatment.


Asunto(s)
Neoplasias de la Mama/cirugía , Metástasis Linfática/diagnóstico por imagen , Linfedema/prevención & control , Imagen Óptica/métodos , Complicaciones Posoperatorias/prevención & control , Axila , Neoplasias de la Mama/patología , Medios de Contraste/administración & dosificación , Medios de Contraste/efectos adversos , Femenino , Humanos , Escisión del Ganglio Linfático/efectos adversos , Escisión del Ganglio Linfático/métodos , Ganglios Linfáticos/diagnóstico por imagen , Ganglios Linfáticos/patología , Metástasis Linfática/patología , Vasos Linfáticos/diagnóstico por imagen , Vasos Linfáticos/patología , Linfedema/etiología , Mastectomía/efectos adversos , Mastectomía/métodos , Oncología Médica/métodos , Imagen Óptica/efectos adversos , Tratamientos Conservadores del Órgano/efectos adversos , Tratamientos Conservadores del Órgano/métodos , Complicaciones Posoperatorias/etiología , Biopsia del Ganglio Linfático Centinela/efectos adversos , Biopsia del Ganglio Linfático Centinela/métodos
20.
Eur Urol ; 75(3): 492-497, 2019 03.
Artículo en Inglés | MEDLINE | ID: mdl-30553615

RESUMEN

BACKGROUND: With the increasing adoption of novel technologies and anatomical techniques, surgical management of benign prostatic hyperplasia (BPH) provides significant benefits in terms of obstruction relief, early urethral catheter removal, and faster return to daily activities. However, the main pitfall of BPH surgery in sexually active men remains ejaculatory dysfunction (EjD), which permanently affects quality of life. OBJECTIVE: To detail a novel technique for marking the intraprostatic urethra through a retrograde injection of indocyanine green to enhance selective dissection of prostatic lobes during urethra-sparing robot-assisted simple prostatectomy (US-RASP) with the use of near-infrared fluorescence imaging (NIFI). DESIGN, SETTING, AND PARTICIPANTS: Between January and September 2017, 12 consecutive male patients, who had BPH, were sexually active, and were motivated to preserve ejaculatory function, underwent US-RASP. SURGICAL PROCEDURE: US-RASP with NIFI to enhance the identification and preservation of the prostatic urethra. MEASUREMENTS: Clinical data were prospectively collected in our institutional RASP dataset. Perioperative and functional outcomes of US-RASP were both graded, and assessed according to Clavien grading system and validated questionnaires postoperatively (International Prostate Symptom Score [IPSS]; Male Sexual Health Questionnaire on EjD [MSHQ-EjD] Short Form) at 3 and 12mo. RESULTS AND LIMITATIONS: Median preoperative prostate size was 102cc (interquartile range [IQR] 88-115). Median operative time was 150min (IQR 145-170). Median estimated blood loss was 250 (IQR 200-350). Continuous bladder irrigation was avoided in 83.4% of patients. Median time to catheter removal was 7d (IQR 7-7) with a median hospital stay of 3d (IQR 2-3). At 1-yr follow-up, median IPSS score, International Index of Erectile Function score, and MSHQ-EjD Short Form score were 5 (IQR 4-8), 26 (IQR 26-28), and 12 (IQR 1-14), respectively. Satisfactory anterograde ejaculation was reported in eight patients (66%). CONCLUSIONS: We described a novel NIFI-guided technique to perform US-RASP. This technique showed promising early functional results, suggesting a significant role of intraprostatic urethral integrity for the preservation of ejaculatory function. PATIENT SUMMARY: We developed a novel robotic technique to perform simple prostatectomy with integral preservation of the prostatic urethra. This technique provided a high rate of ejaculatory function preservation.


Asunto(s)
Eyaculación , Colorantes Fluorescentes/administración & dosificación , Verde de Indocianina/administración & dosificación , Imagen Óptica/métodos , Prostatectomía/métodos , Hiperplasia Prostática/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Uretra/cirugía , Humanos , Tiempo de Internación , Masculino , Imagen Óptica/efectos adversos , Tratamientos Conservadores del Órgano , Prostatectomía/efectos adversos , Hiperplasia Prostática/diagnóstico , Hiperplasia Prostática/fisiopatología , Calidad de Vida , Recuperación de la Función , Procedimientos Quirúrgicos Robotizados/efectos adversos , Conducta Sexual , Disfunciones Sexuales Fisiológicas/etiología , Disfunciones Sexuales Fisiológicas/fisiopatología , Disfunciones Sexuales Fisiológicas/prevención & control , Factores de Tiempo , Resultado del Tratamiento , Uretra/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA