Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 7.237
Filtrar
1.
J Cardiovasc Surg (Torino) ; 65(2): 119-123, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38618696

RESUMEN

This article summarizes the key findings in literature up to date on the endovascular treatment of complex abdominal aortic aneurysms (AAAs) employing the chimney technique. Additionally, an unexplored pitfall is described regarding the target vessel angulation. Although balloon-expandable covered stents present more favorable configuration in downward-oriented target vessels, transverse and upward-oriented target vessels may benefit from other endovascular techniques imploring careful case planning and further investigation on the topic.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Arteria Renal , Stents , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Humanos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Arteria Renal/cirugía , Arteria Renal/diagnóstico por imagen , Resultado del Tratamiento , Procedimientos Endovasculares/instrumentación , Diseño de Prótesis , Factores de Riesgo
2.
J Cardiovasc Surg (Torino) ; 65(2): 124-131, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635285

RESUMEN

INTRODUCTION: We performed a systematic review and meta-analysis to assess the existing published evidence regarding the safety and efficacy of the endovascular aortic repair with chimney technique (ch-EVAR) and physician-modified stent-grafts (PMSGs) for the treatment of pararenal aortic aneurysm repair. EVIDENCE ACQUISITION: A systematic search of all relevant studies reported until October 2023 according to the PRISMA (preferred reporting items for systematic reviews and meta-analyses) guidelines was performed. The pooled 30-day mortality, peri- and postoperative complication rates were estimated using fixed or random effect methods. EVIDENCE SYNTHESIS: A total of 679 study titles were identified by the initial search strategy, of which 16 were considered eligible for inclusion in the meta-analysis. A total of 1094 patients (ch-EVAR N.=861 and PMSG N.=233) (90% male) were identified. The pooled 30-day mortality rate was 3.4% for ch-EVAR and 2.6% for PMSG. The major adverse events (MAE) in the early period was 14.7% for ch-EVAR and 18.5% PMSG, respectively. Higher occlusion rate was observed of the chimney stents grafts (8.2%) than the bridging stents (1.4%) during the follow-up period. CONCLUSIONS: Ch-EVAR and physician-modified technology are safe with low 30-day mortality in elective settings for pararenal aortic aneurysms repair. No significant differences were seen between the two surgical methods regarding the early major adverse events rate. However, higher occlusion rate for the chimneys can be expected over time.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Complicaciones Posoperatorias , Diseño de Prótesis , Stents , Humanos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Procedimientos Endovasculares/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Resultado del Tratamiento , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/mortalidad , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Masculino , Femenino , Anciano , Factores de Tiempo , Medición de Riesgo , Persona de Mediana Edad
3.
J Cardiovasc Surg (Torino) ; 65(2): 110-118, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635286

RESUMEN

BACKGROUND: The aim of this study was to evaluate the anatomical feasibility of current available fenestrated endografts (FEVAR) and on-label chimney technique (EnChEVAR) in patients with complex abdominal aortic aneurysms (C-AAA). METHODS: Feasibility of EnChEVAR (Endurant II/IIS CE-marked [Medtronic]) and 4 types of FEVAR (Zenith Fenestrated CE-marked, Zenith Fenestrated Low-Profile [LP] custom-made device [CMD] [Cook Medical], Fenestrated Anaconda LoPro90 CMD, Fenestrated Treo CMD [Terumo Aortic]) was assessed according to the manufacturer's instructions for use. Computed tomography angiograms of patients with C-AAA previously included in the Protagoras 2.0 study were retrospectively reviewed. The aortic coverage was ideally planned to involve a maximum of two chimney grafts or fenestrations. RESULTS: Iliac access and aortic neck of 73 C-AAAs were analyzed. The overall feasibility was significantly different between EnChEVAR (33%) and FEVAR (Zenith Fenestrated 15%, Zenith Fenestrated LP 15%, Fenestrated Anaconda LoPro90 45%, Fenestrated Treo 48%). The iliac access feasibility was significantly lower for Zenith Fenestrated with standard profile compared to all other grafts. The aortic neck feasibility was significantly higher for EnChEVAR and both Terumo Aortic fenestrated stent grafts, compared to both Cook Medical grafts. The treatment using any of the three current available fenestrated grafts with lower profile (Zenith Fenestrated LP, Fenestrated Anaconda LoPro90, Fenestrated Treo) would have been feasible in 71% of the cases. CONCLUSIONS: Most of the patients treated by ChEVAR would have not been treated by first generation fenestrated stent graft. The current available fenestrated endografts, with lower profile and suitable also for angulated necks, increase the anatomical feasibility.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Angiografía por Tomografía Computarizada , Procedimientos Endovasculares , Estudios de Factibilidad , Diseño de Prótesis , Stents , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Estudios Retrospectivos , Femenino , Masculino , Anciano , Resultado del Tratamiento , Anciano de 80 o más Años , Medios de Contraste , Aortografía
4.
J Cardiovasc Surg (Torino) ; 65(2): 106-109, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635287

RESUMEN

BACKGROUND: The aim of this study was to evaluate the early results of the CE-marked standardized device combination consisting of Endurant and the Radiant chimney graft (En-ChEVAR) for the treatment of juxtarenal aortic aneurysms. METHODS: We analyzed multicentric non-industry sponsored case series evaluating the EnChEVAR technique for patients treated between December 2022 and February 2024. Clinical, perioperative procedure-related and radiological data were collected. The primary outcome measure was the freedom of a type Ia gutter-related endoleak at postoperative computed tomography angiography (CTA). Secondary outcome measures included early type Ia endoleak-related reinterventions, target vessel complications including dissection or loss of target vessel, major adverse events, and mortality. Continuous variables were presented as median (interquartile range [IQR]) and categorical variables as count and percentage. RESULTS: Ten patients were included in the present study. Eight (80%) were males, in nine cases a single chimney was implanted, and the other one was a double chimney graft placement. The treated aneurysms had an infrarenal neck length of 3.4 (1.2) mm. The rate of main body oversizing was 30%. The new neck length after chimney graft placement was 18 (3) mm. The median procedural time was 130 (17) mm, contrast medium use was 109 (26) mL, radiation time was 45 (12) min. The technical success was 100%. No type Ia endoleak was detected at the postoperative CTA. There were no target vessel issues. No major adverse events or death were observed. CONCLUSIONS: First reported cohort of patients treated with EnChEVAR demonstrated reproducible clinical and procedural outcomes within the 3 vascular centers with total exclusion of the aneurysms, patent renal arteries, and no evidence of gutter-related type IA endoleak. Further evidence with larger sample size of treated patients and longer follow-up are needed.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Diseño de Prótesis , Sistema de Registros , Humanos , Masculino , Femenino , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Anciano , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Endofuga/etiología , Factores de Tiempo , Resultado del Tratamiento , Anciano de 80 o más Años , Stents , Estudios Retrospectivos , Factores de Riesgo , Etiquetado de Productos , Reparación Endovascular de Aneurismas
5.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38603631

RESUMEN

When neither surgical valve replacement nor transcatheter aortic valve implantation is possible, performing an apico-aortic conduit remains a therapeutic option. This procedure has become rare and the rigid angled apical connectors usually used to facilitate ventricular anastomosis are no longer commercially available. We described the technique that we performed on a 60-year-old patient with readily available material.


Asunto(s)
Válvula Aórtica , Humanos , Persona de Mediana Edad , Válvula Aórtica/cirugía , Masculino , Aorta/cirugía , Estenosis de la Válvula Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/instrumentación
6.
Eur J Cardiothorac Surg ; 65(5)2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38569918

RESUMEN

OBJECTIVES: Our goal was to access early and mid-term outcomes of a gutter-plugging chimney stent graft for treatment of Stanford type B aortic dissections in the clinical trial Prospective Study for Aortic Arch Therapy with stENt-graft for Chimney technology (PATENCY). METHODS: Between October 2018 and March 2022, patients with Stanford type B aortic dissections were treated with the Longuette chimney stent graft in 26 vascular centres. The efficiency and the incidence of adverse events over 12 months were investigated. RESULTS: A total of 150 patients were included. The technical success rate was 99.33% (149/150). The incidence of immediate postoperative endoleak was 5.33% (8/150, type I, n = 6; type II, n = 1; type IV, n = 1) neurologic complications (stroke or spinal cord ischaemia); the 30-day mortality was 0.67% (1/150) and 1.33% (2/150), respectively. During the follow-up period, the median follow-up time was 11.67 (5-16) months. The patent rate of the Longuette graft was 97.87%. Two patients with type I endoleak underwent reintervention. The follow-up rate of the incidence of retrograde A type aortic dissection was 0.67% (1/150). There was no paraplegia, left arm ischaemia or stent migration. CONCLUSIONS: For revascularization of the left subclavian artery, the Longuette chimney stent graft can provide an easily manipulated, safe and effective endovascular treatment. It should be considered a more efficient technique to prevent type Ia endoleak. Longer follow-up and a larger cohort are needed to validate these results. CLINICAL TRIAL REGISTRY NUMBER: NCT03767777.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Stents , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/instrumentación , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Estudios Prospectivos , Diseño de Prótesis , Stents/efectos adversos , Resultado del Tratamiento , Estudios de Casos y Controles
7.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38577923

RESUMEN

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Asunto(s)
Disección Aórtica , Insuficiencia de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis Vascular , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Masculino , Disección Aórtica/cirugía , Disección Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/etiología , Insuficiencia de la Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/fisiopatología , Persona de Mediana Edad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Diseño de Prótesis , Prótesis Vascular , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta/cirugía , Aneurisma de la Aorta/diagnóstico por imagen , Aortografía
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38598445

RESUMEN

OBJECTIVES: The indications for use, evidence base and experience with the novel noncovered open hybrid surgical stents for acute type A aortic dissection repair for concurrent stabilization of the 'downstream' aorta remains limited. We review the evidence base and the development of these stents. METHODS: Data were collected from Pubmed/Medline literature search to develop and review the evidence base for safety and efficacy of non-covered surgical stents. Existing guidelines for use and developments were reviewed. RESULTS: A single randomized control trial and 4 single-centre studies were included in the review with a total worldwide experience of 241 patients. The deployment was easy and did not add significantly to the primary operation. The mortality and new stroke ranged from 6.3-18.7%. Safe and complete deployment was accomplished in 92-100%. There was no device-related reintervention. There was a significant improvement in malperfusion in over 90% of the cases with varying degrees of remodelling (60-90%) of the downstream aorta. CONCLUSIONS: Open noncovered stent grafts represent a major technical advancement as an adjunct procedure for acute dissection repairs, e.g. hemiarch repair. It has potential for wider use by non-aortic surgeons due to simplicity of technique. Limited safety and efficacy data confirm the device to be safe, feasible and reproducible with potential for wider adoption. However, long-term trial and registry data are required before recommendations for standard use outside of high-volume experienced aortic centres.


Asunto(s)
Disección Aórtica , Implantación de Prótesis Vascular , Stents , Humanos , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/métodos , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/métodos , Procedimientos Endovasculares/efectos adversos , Enfermedad Aguda , Diseño de Prótesis , Aneurisma de la Aorta Torácica/cirugía , Resultado del Tratamiento , Aneurisma de la Aorta/cirugía
9.
J Cardiovasc Surg (Torino) ; 65(2): 85-98, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38635284

RESUMEN

Endovascular aortic repair (EVAR) is nowadays the establishment treatment for patients with abdominal aortic aneurysm (AAA) both in elective and urgent setting. Despite the large applicability and satisfactory results, the presence of hostile iliac anatomy affects both technical and clinical success. This narrative review aimed to report the impact of iliac access and related adjunctive procedures in patients undergoing EVAR in elective and non-elective setting. Hostile iliac access can be defined in presence of narrowed, tortuous, calcified, or occluded iliac arteries. These iliac characteristics can be graded by the anatomic severity grade score to quantitatively assess anatomic complexity before undergoing treatment. Literature shows that iliac hostility has an impact on device navigability, insertion and perioperative and postoperative results. Overall, it has been correlated to higher rate of access issues, representing up to 30% of the first published EVAR experience. Recent innovations with low-profile endografts have reduced large-bore sheaths related issues. However, iliac-related complications still represent an issue, and several adjunctive endovascular and surgical strategies are nowadays available to overcome these complications during EVAR. In urgent settings iliac hostility can significantly impact on particular time sensitive procedures. Moreover, in case of severe hostility patients might be written off for EVAR repair might be inapplicable, exposing to higher mortality/morbidity risk in this urgent/emergent setting. In conclusion, an accurate anatomical evaluation of iliac arteries during preoperative planning, materials availability, and skilled preparation to face iliac-related issues are crucial to address these challenges.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Procedimientos Quirúrgicos Electivos , Procedimientos Endovasculares , Arteria Ilíaca , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Arteria Ilíaca/cirugía , Arteria Ilíaca/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Resultado del Tratamiento , Factores de Riesgo , Prótesis Vascular , Complicaciones Posoperatorias/etiología
10.
J Cardiovasc Surg (Torino) ; 65(2): 99-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38551514

RESUMEN

The initial success and widespread adoption of endovascular aneurysm repair (EVAR) for the treatment of abdominal aortic aneurysms have been tempered by numerous reports of secondary interventions and increased long-term mortality compared with open repair. Over the past decade, several studies on postoperative sac dynamics after EVAR have suggested that the presence of sac regression is a benign feature with a favorable prognosis. Conversely, increasing sacs and even stable sacs can be indicators of more unstable sac behavior with worse outcomes in the long-term. Endoleaks were initially perceived as the main drivers of sac behavior. However, the observation that sac regression can occur in the presence of endoleaks, and vice versa - increasing sacs without evidence of endoleak - on imaging studies, suggests the involvement of other contributing factors. These factors can be divided into anatomical factors, patient characteristics, sac thrombus composition, and device-related factors. The shift of interest away from especially type 2 endoleaks is further supported by promising results with the use of EndoAnchors regarding postoperative sac behavior. This review provides an overview of the existing literature on the implications and known risk factors of post-EVAR sac behavior, describes the accurate measurement of sac behavior, and discusses the use of EndoAnchors to promote sac regression.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Endofuga , Procedimientos Endovasculares , Humanos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Endofuga/etiología , Factores de Riesgo , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Diseño de Prótesis
12.
Ann Vasc Surg ; 103: 122-132, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38387799

RESUMEN

BACKGROUND: In endovascular aortic repair (EVAR), preemptive embolization of sac branch vessels is effective in preventing postoperative type II endoleak (T2EL). However, this technique has not been widely adopted especially for lumbar arteries (LAs) because of technical difficulties and time constraints. This study aimed to investigate the efficacy of nonselective sac coil embolization, which is a simpler surgical method, in postoperative sac shrinkage for patients at a high risk of T2EL from LAs. METHODS: We retrospectively assessed 76 patients who underwent elective EVAR for abdominal aortic aneurysm with 4 or more patent LAs or at least 1 patent LA of ≥2 mm at our hospital between January 2014 and December 2022. The patients who underwent sac coil embolization were included in Group Ⅰ (n = 20), and the others were divided into 2 groups: those with an inferior mesenteric artery that was originally occluded or embolized by coils or stent graft bodies (Group Ⅱ, n = 21), and those without that (Group Ⅲ, n = 35). In Group Ⅰ, 0.035-inch coils were inserted into the sac after complete stent graft deployment. The cumulative incidence of sac shrinkage (≥5 mm) was compared between the groups. Further, univariable and multivariable Cox regression analyses were used to determine the predictors of sac shrinkage. RESULTS: Sac shrinkage (≥5 mm) was observed more frequently in Group Ⅰ (50%) than in Group Ⅱ (19%) and Group Ⅲ (17%) (P = 0.052 and 0.043, respectively). The cumulative incidence of sac shrinkage was significantly higher in Group Ⅰ than in Group Ⅱ (log-rank P = 0.039) and Group Ⅲ (log-rank P = 0.024). Multivariable Cox regression analyses revealed that sac embolization was a significant predictor of sac shrinkage (hazard ratio, 4.23; 95% confidence interval, 1.66-10.8; P = 0.003). CONCLUSIONS: Nonselective sac coil embolization in EVAR is potentially effective for sac shrinkage in the early postoperative phase in patients at high risk of T2EL from LAs. This simple procedure may improve prognosis after EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Embolización Terapéutica , Endofuga , Procedimientos Endovasculares , Humanos , Endofuga/etiología , Endofuga/prevención & control , Endofuga/terapia , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Masculino , Estudios Retrospectivos , Embolización Terapéutica/efectos adversos , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Anciano , Femenino , Factores de Riesgo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Resultado del Tratamiento , Anciano de 80 o más Años , Factores de Tiempo , Medición de Riesgo , Prótesis Vascular , Stents , Reparación Endovascular de Aneurismas
13.
Ann Vasc Surg ; 103: 74-80, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38395342

RESUMEN

BACKGROUND: Transcarotid artery revascularization (TCAR) is a hybrid technique with excellent initial outcomes. The technical success and safety of TCAR is heavily dependent on an anatomically suitable common carotid artery (CCA). Many patients do not meet anatomic criteria and therefore are not eligible for this therapy. We sought to extend the eligibility of TCAR to patients with unfavorable CCA anatomy via the adoption of a prosthetic arterial conduit. METHODS: A single-center retrospective study of patients with critical carotid artery stenosis who underwent TCAR via a prosthetic conduit between June 2019 and October 2021 was performed. All patients in the study were considered high-risk for carotid endarterectomy based on anatomic features, such as restenosis post-carotid endarterectomy and neck radiation. Unfavorable CCA anatomy was defined as a clavicle to carotid bifurcation distance <5 cm, a CCA diameter <6 mm, and/or significant atherosclerotic disease at the intended arterial access site. The primary outcome of interest was technical success. Secondary outcomes included perioperative complications, intermediate and long-term patency, intermediate and long-term stroke and/or mortality and in-hospital length of stay. Follow-up ranged from 1 to 29 months. RESULTS: Eight patients underwent 10 TCAR procedures via a prosthetic conduit. A total of 2 procedures (20%) were performed on female patients and 8 procedures (75%) were performed on male patients. The mean age was 65 years old (standard deviation 11 years). Technical success was 100%. The 30-day ipsilateral stroke rate was 0%. The 30-day patency was 90%. There was no re-exploration for hemorrhage and 30 day mortality was 0%. CONCLUSIONS: TCAR is an excellent option for carotid artery revascularization. Unfavorable CCA anatomy has limited its applicability. TCAR via a prosthetic conduit has the potential to expand eligibility for this promising therapy.


Asunto(s)
Implantación de Prótesis Vascular , Prótesis Vascular , Arteria Carótida Común , Estenosis Carotídea , Estudios de Factibilidad , Grado de Desobstrucción Vascular , Humanos , Masculino , Femenino , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Estenosis Carotídea/diagnóstico por imagen , Estenosis Carotídea/cirugía , Estenosis Carotídea/mortalidad , Factores de Tiempo , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Persona de Mediana Edad , Arteria Carótida Común/cirugía , Arteria Carótida Común/diagnóstico por imagen , Arteria Carótida Común/fisiopatología , Factores de Riesgo , Diseño de Prótesis , Anciano de 80 o más Años , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Medición de Riesgo
14.
Ann Vasc Surg ; 103: 31-37, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38301852

RESUMEN

BACKGROUND: To evaluate the short-term and mid-term safety and efficacy of stent-graft compared with bare stents for treatment of aortoiliac occlusive disease (AIOD). METHODS: One hundred eighty three patients diagnosed with AIOD who received stent implantation at 3 vascular centers in north China between January 2019 and December 2021 were enrolled. Patients were divided into those undergoing stent-graft (Group A; n = 67) or bare stent (Group B; n = 116) implantation for retrospective cohort analysis. Efficacy was assessed as surgical success rate and rate of freedom from clinically driven target lesion reintervention at each follow-up time point. Safety was assessed by the rate of perioperative complication, major limb amputation, and aortoiliac artery-related mortality. RESULTS: There were no preoperative baseline differences between the 2 groups (P > 0.05). The surgical success was 91.04% for Group A, significantly higher than that for Group B (79.31%; P < 0.05). Incidence of perioperative complications was 2.98% for Group A, significantly lower than that for Group B (9.48%, P < 0.05), as was the rate of major limb amputation (A: 1.49% vs. B: 5.17%) and aortoiliac artery-related mortality (A: 1.49% vs. B: 4.31%), although these 2 indicators were not significantly different (P > 0.05). Follow-up rates were 91.8% for the total follow-up time of 3 years. Kaplan-Meier survival curve analysis gave significantly higher 1-year and 2-year freedom from clinically driven target lesion reintervention for Group A (98.51% and 95.52%) than for Group B (95.69% and 89.66%, P < 0.05). CONCLUSIONS: Stent-graft is more effective and safer than bare stent in the treatment of AIOD.


Asunto(s)
Amputación Quirúrgica , Enfermedades de la Aorta , Arteriopatías Oclusivas , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Arteria Ilíaca , Stents , Grado de Desobstrucción Vascular , Humanos , Masculino , Femenino , Arteria Ilíaca/cirugía , Arteria Ilíaca/diagnóstico por imagen , Estudios Retrospectivos , Persona de Mediana Edad , Factores de Tiempo , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Anciano , Enfermedades de la Aorta/cirugía , Enfermedades de la Aorta/diagnóstico por imagen , Enfermedades de la Aorta/mortalidad , Arteriopatías Oclusivas/cirugía , Arteriopatías Oclusivas/diagnóstico por imagen , Arteriopatías Oclusivas/mortalidad , China , Resultado del Tratamiento , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Factores de Riesgo , Recuperación del Miembro , Diseño de Prótesis , Complicaciones Posoperatorias/etiología , Medición de Riesgo
15.
Vasc Endovascular Surg ; 58(5): 554-558, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38166566

RESUMEN

Aortic graft and endograft infections remain a significant source of morbidity and mortality after abdominal aortic aneurysm repair. With graft excision and extra-anatomic bypass, an infrarenal aortic stump remains which can have suture line dehiscence and catastrophic stump blowout. Treatment of this is extremely challenging, especially for severely co-morbid patients who cannot undergo major surgery, or in patients with a hostile abdomen. We present a case study of a 74-year-old male found to have an aortoenteric fistula (AEF). This case broadens operative options for this type of patient population by demonstrating an endovascular technique for addressing aortic stump blowout by parallel grafting and coil embolization of the visceral aorta.


Asunto(s)
Aneurisma de la Aorta Abdominal , Implantación de Prótesis Vascular , Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Fístula Intestinal , Fístula Vascular , Humanos , Masculino , Anciano , Embolización Terapéutica/instrumentación , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Resultado del Tratamiento , Procedimientos Endovasculares/instrumentación , Fístula Vascular/diagnóstico por imagen , Fístula Vascular/etiología , Fístula Vascular/cirugía , Fístula Vascular/terapia , Aneurisma de la Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Fístula Intestinal/diagnóstico por imagen , Fístula Intestinal/etiología , Fístula Intestinal/cirugía , Fístula Intestinal/terapia , Aortografía , Angiografía por Tomografía Computarizada , Aorta Abdominal/diagnóstico por imagen , Aorta Abdominal/cirugía
16.
Vasc Endovascular Surg ; 58(5): 505-511, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38258617

RESUMEN

INTRODUCTION: We sought to examine midterm results and remodeling effect of false-lumen occlusion treatment using AFX VELA in case of chronic dissection repair. MATERIAL AND METHODS: From June 2019 to May 2022, we performed false lumen occlusion treatment using a modified Candy-Plug technique with AFX VELA on 8 chronic aortic dissection patients with a patent false lumen. We collected operative data, short-term clinical outcomes, mid-term clinical outcomes and imaging test results. We conducted follow-up examinations at postoperative, 6-month and 1-, 2- and 3-year intervals, including contrast-enhanced computed tomography to evaluate the diameter, false lumen thrombosis and any events. RESULTS: The average time from the symptom onset to the thoracic endovascular repair was 81.5 (35-155) months. The aorta showed aneurysmal dilation with an average maximum short-axis diameter of 58.9 (41-91) mm. Two cases needed emergency surgery due to rupture and impending rupture. There were no postoperative deaths. Complete thrombosis within the false lumen was achieved in 6 cases (75%), but 2 cases had incomplete thrombosis, requiring additional treatment. The mean maximum diameter showed a significant decrease at 6 months, 1 year and 2 years postoperatively compared to preoperative measurements (P < .05). CONCLUSION: We showed the results of false lumen occlusion treatment using the AFX VELA cuff. We observed favorable clinical outcomes and remodeling effects. While the long-term durability and efficacy of this technique in aortic remodeling will need to be monitored with further observation, the use of this cuff is considered a reliable approach to false lumen occlusion treatment.


Asunto(s)
Aneurisma de la Aorta Torácica , Disección Aórtica , Implantación de Prótesis Vascular , Prótesis Vascular , Procedimientos Endovasculares , Humanos , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/cirugía , Disección Aórtica/fisiopatología , Masculino , Persona de Mediana Edad , Resultado del Tratamiento , Enfermedad Crónica , Anciano , Femenino , Factores de Tiempo , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/efectos adversos , Estudios Retrospectivos , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/cirugía , Aneurisma de la Aorta Torácica/fisiopatología , Diseño de Prótesis , Stents , Remodelación Vascular
17.
Anticancer Res ; 42(3): 1351-1358, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35220227

RESUMEN

BACKGROUND/AIM: Collecting duct carcinoma, epithelioid angiosarcoma and neuroendocrine/carcinoid tumor are uncommon renal malignancies, and their association with tumor thrombus extending into the inferior vena cava is extremely rare. Owing to the rarity of the above-mentioned malignancies and short follow-up of the cases published in the literature, the prognosis and clinical behavior of these tumors remains unclear. Up to date, the culprit of treatment is surgical management with radical nephrectomy, lymph node dissection, thrombectomy and vascular reconstruction if necessary. PATIENTS AND METHODS: We herein describe in detail the first cases published of the above-mentioned renal malignancies associated with extensive inferior vena cava (IVC) thrombus, in which complex vascular reconstruction was performed. RESULTS: Three male patients were identified as having collecting duct carcinoma, epithelioid angiosarcoma and neuroendocrine/carcinoid tumor with IVC involvement. Tumor thrombus levels were II, I and IIIc respectively. Patient ages were 42, 60 and 47 years and tumor sizes were 9.2, 10.9 and 3.7 cm correspondingly. Patient 2 underwent cavectomy, IVC replacement using polytetrafluoroethylene (Gore-Tex®) vascular graft and IVC filter deployment inside the graft. None of the patients developed any pulmonary emboli postoperatively. At the last follow-up, IVC graft for patient 2 remained patent. CONCLUSION: Owing to the rarity of the aforementioned malignancies and short follow-up of cases published in the literature, the prognosis and clinical behavior of these tumors remains unclear. Up to date, the culprit of treatment is surgical management with radical nephrectomy, lymph node dissection, thrombectomy and vascular reconstruction if necessary. Polytetrafluoroethylene (Gore-Tex) vascular grafts are an excellent and safe option for complex vascular reconstructions in patients with evidence of IVC invasion.


Asunto(s)
Implantación de Prótesis Vascular , Tumor Carcinoide/cirugía , Carcinoma de Células Renales/cirugía , Hemangiosarcoma/cirugía , Neoplasias Renales/cirugía , Nefrectomía , Trombectomía , Vena Cava Inferior/cirugía , Adulto , Implantación de Prótesis Vascular/instrumentación , Tumor Carcinoide/diagnóstico por imagen , Tumor Carcinoide/patología , Carcinoma de Células Renales/diagnóstico por imagen , Carcinoma de Células Renales/patología , Hemangiosarcoma/diagnóstico por imagen , Hemangiosarcoma/patología , Humanos , Neoplasias Renales/diagnóstico por imagen , Neoplasias Renales/patología , Masculino , Persona de Mediana Edad , Invasividad Neoplásica , Resultado del Tratamiento , Vena Cava Inferior/diagnóstico por imagen , Vena Cava Inferior/patología
18.
Anticancer Res ; 42(3): 1579-1588, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35220255

RESUMEN

BACKGROUND/AIM: Management strategies for pseudoaneurysm rupture after pancreatic resection have not yet been firmly established due to its low incidence and effects of environmental variability among centers. This study aimed to provide a basis for treatment strategy improvement. PATIENTS AND METHODS: Clinical features and outcomes of 29 patients who experienced pseudoaneurysm formation or rupture following pancreatic resection were retrospectively reviewed. RESULTS: The incidence of pseudoaneurysm formation was 2.8%. In 28 of 29 patients, pseudoaneurysm was identified via emergent dynamic computed tomography (CT). The rates of complete cessation of bleeding by interventional radiology (IVR) and surgical intervention were 88% and 100%, respectively. Mortality rate was 13.8%. Four patients treated by IVR died, including three of massive bleeding and one of liver failure. CONCLUSION: Patients with suspected pseudoaneurysm rupture after pancreatic resection should undergo immediate CT. Open surgery is preferable for patients with incomplete hemostasis by IVR or those who cannot immediately undergo IVR, however, IVR is an effective alternative.


Asunto(s)
Aneurisma Falso/terapia , Aneurisma Roto/terapia , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Pancreatectomía/efectos adversos , Neoplasias Pancreáticas/cirugía , Pancreaticoduodenectomía/efectos adversos , Adulto , Anciano , Anciano de 80 o más Años , Aneurisma Falso/diagnóstico por imagen , Aneurisma Falso/etiología , Aneurisma Falso/mortalidad , Aneurisma Roto/diagnóstico por imagen , Aneurisma Roto/etiología , Aneurisma Roto/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/instrumentación , Embolización Terapéutica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radiografía Intervencional , Estudios Retrospectivos , Stents , Factores de Tiempo , Tokio , Tomografía Computarizada por Rayos X , Resultado del Tratamiento
19.
J Thorac Cardiovasc Surg ; 163(2): 568-574.e1, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32653283

RESUMEN

OBJECTIVE: Acute type I aortic dissection (AAD) represents a surgical emergency with time-dependent evolving complications. Frozen elephant trunk (FET) enables false lumen exclusion downstream but is still debated in AAD due to its greater dimension of surgery. To combine the benefits of fast proximal repair with the FET benefits, a 3-zone hybrid graft was developed consisting of an ascending polyester portion, an arch noncovered stent, and a descending stent graft. Mid-term results of this new technique are presented. METHODS: A total of 6 patients (age mean 69 years) with type I AAD in critical status (Penn classification B n = 5, BC n = 1) were operated between July 2016 and April 2018 using the 3-zone hybrid graft. The device was implanted on the basis of strict compassionate use. Operations were performed under distal hypothermic circulatory arrest and selective antegrade cerebral perfusion (SACP). RESULTS: Operative mortality was 17% (n = 1). Mean crossclamp and SACP time were 92 and 34 minutes, respectively, but came down in the last 2 cases to 75/65 crossclamp and 23/24 SACP minutes each. During follow up, mean 19 ± 12 months, one endovascular extension downstream was performed. Imaging control demonstrated no anastomotic-related proximal entry and no true lumen collapse downstream. CONCLUSIONS: The goal to achieve fast and reliable repair of complicated type I AAD down to midthoracic level seems to be achievable. Noncovered stenting of the head vessel's origin does not cause stenosis or obstruction. A multicenter studying of this concept is next.


Asunto(s)
Aneurisma de la Aorta/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Enfermedad Aguda , Adulto , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta/diagnóstico por imagen , Aneurisma de la Aorta/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Humanos , Masculino , Diseño de Prótesis , Factores de Tiempo , Resultado del Tratamiento
20.
J Thorac Cardiovasc Surg ; 163(2): 539-548.e2, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-32654872

RESUMEN

OBJECTIVE: Thoracic endovascular aortic repair is the standard of care for acute complicated type B aortic dissections, but long-term single-device outcomes are limited. METHODS: Fifty patients were treated with the Valiant Captivia thoracic stent graft (Medtronic Inc, Santa Rosa, Calif) for acute complicated type B aortic dissections in this prospective, nonrandomized Dissection Trial. All-cause mortality, secondary procedures, and serious adverse events were assessed, and a core lab evaluated images for aortic remodeling. RESULTS: Compliance for both clinical and imaging follow-up was 78% (18 out of 23) for the available patients at 5 years. Notable baseline characteristics were 86% of patients (43 out of 50) had malperfusion, 20% (10 out of 50) had ruptures, and 94% (46 out of 49) had DeBakey class IIIB dissections. The 5-year freedom from dissection-related mortality, secondary procedures related to the dissection, and endoleaks was 83%, 86%, and 85%, respectively. After 5 years, 89% of patients (16 out of 18) had a completely thrombosed false lumen in the stented segment of the aorta and the true lumen diameter over the length of stent graft was stable or increased for 94% of patients (16 out of 17) while the false lumen diameter was stable or decreased in 77% (13 out of 17) after 5 years. CONCLUSIONS: In the Dissection Trial, patients experienced positive and sustained measures of aortic remodeling. Survival outcomes, need for secondary procedures, and adverse event rates were consistent with previous thoracic endovascular aortic repair studies. Although limitations exist with the follow-up compliance, the Valiant Captivia thoracic stent graft system was effective in the long-term management of acute complicated type B aortic dissections in this patient population with a challenging condition.


Asunto(s)
Aneurisma de la Aorta Torácica/cirugía , Disección Aórtica/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Enfermedad Aguda , Anciano , Disección Aórtica/diagnóstico por imagen , Disección Aórtica/mortalidad , Aneurisma de la Aorta Torácica/diagnóstico por imagen , Aneurisma de la Aorta Torácica/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/cirugía , Estudios Prospectivos , Reoperación , Stents , Factores de Tiempo , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA