Clin Oral Investig ; 28(10): 524, 2024 Sep 13.
Artículo en Inglés | MEDLINE | ID: mdl-39269506

RESUMEN

OBJECTIVES: Simplifying interdental space cleaning is a constantly discussed topic. The present study aimed to compare the cleansing efficacy of an oral irrigator with that of dental flossing in adolescent patients with fixed braces after four weeks of home-use. MATERIALS AND METHODS: The study design is a randomized, single-blinded cross-over study. Following a twenty-eight-day period of product utilization in a home setting, a comparative analysis was conducted on hygiene indices, the Rustogi Modified Navy Plaque Index (RMNPI) and the Gingival Bleeding Index (GBI), between the test group (oral irrigator) and the control group (dental floss). RESULTS: Seventeen adolescent individuals completed the study. After 28 days of cleaning with the oral irrigator, RMNPI was 58.81% (55.31-66.47) compared to 59.46% (52.68-68.67) with dental floss (p = 0.070). Subgroup analyses did not indicate the superiority of either method. GBI after the test phase with the oral irrigator was 28.93% (23.21-33.97) and insignificantly higher compared to 26.40% (21.01-31.41) achieved with dental floss (p = 0.1585). CONCLUSIONS: Neither of the two products demonstrated statistically significant superiority in terms of cleaning efficacy. Therefore, no recommendation can be made in favor of one over the other. It was found that the high initial hygiene indices for fixed orthodontic appliances could be improved through increased awareness and precise instruction. CLINICAL RELEVANCE: For adolescent patients who struggle to use interdental brushes an oral irrigator may be suggested as a simple alternative in hard-to-reach areas, such as those around a fixed dental appliance.


Asunto(s)
Estudios Cruzados , Humanos , Adolescente , Masculino , Femenino , Método Simple Ciego , Dispositivos para el Autocuidado Bucal , Índice Periodontal , Aparatos Ortodóncicos Fijos , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Higiene Bucal/educación , Índice de Higiene Oral
5.
Lasers Med Sci ; 39(1): 213, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39129047

RESUMEN

The aim of this study is to evaluate the effect of different irrigation activation methods on root canal sealer penetration in teeth with simulated internal root resorption (IRR) and calcium hydroxide (CH) applied using a confocal laser scanning microscope (CLSM). 60 incisors with a single root and a single canal were included in the study. IRR cavities were created in the middle third of the root canal, and CH was placed. The samples were randomly divided into 4 groups (n = 15) according to the irrigation activation method to be tested: standard needle irrigation (SNI), sonic activation (EDDY), photon-induced photoacoustic flow (PIPS), and shock wave enhanced emission photoacoustic flow (SWEEPS). After irrigation activation applications, the root canals were obturated. Sections of 1.0 ± 0.1 mm were taken from the apical, middle, and coronal regions of each sample. The penetration area (µm2) and maximum penetration depth (µm) of the root canal sealer were examined by CLSM and analyzed using ImageJ software. Statistical analysis was performed with a one-way ANOVA and post-hoc Tukey test at the P < 0.05 significance level. Among all irrigation activation methods tested, both the penetration area and maximum penetration depth of the root canal sealer were greater in the coronal region than in the apical region (p < 0.05). In the IRR region, there was no difference in terms of maximum penetration depth between PIPS and SWEEPS (p > 0.05), it was highest in SWEEPS (p < 0.05). PIPS and SWEEPS were better than other irrigation activation methods in the penetration of root canal sealer in the resorption areas of teeth with IRR.


Asunto(s)
Hidróxido de Calcio , Microscopía Confocal , Resorción Radicular , Humanos , Materiales de Obturación del Conducto Radicular , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Irrigantes del Conducto Radicular/administración & dosificación , Preparación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Incisivo
6.
J Endod ; 50(10): 1463-1471, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39029891

RESUMEN

INTRODUCTION: This ex vivo study evaluated the disinfecting and cleaning effects of root canal preparation using sodium hypochlorite irrigation with 3 different needle designs. METHODS: Mesial roots from extracted mandibular molars with Vertucci class II configuration were anatomically matched based on micro-computed tomography (micro-CT) analyses and distributed into 3 groups (n = 18/group). The canals were contaminated with a mixed bacterial culture for 30 days and then subjected to preparation using 2.5% sodium hypochlorite irrigation with open-ended flat needle (3 mm short of the working length - WL), closed-ended side-vented irrigation needle (1 mm short of the WL), or a closed-ended plastic needle with 2 lateral outlets (TruNatomy) (1 mm short of the WL). Bacteriological samples were taken from the canals before (S1) and after preparation (S2). After another micro-CT scan, the roots were sectioned and samples were also taken from the apical canal segment (S3). Bacterial reduction was assessed by quantitative real-time polymerase chain reaction. The amount of accumulated hard tissue debris was evaluated by micro-CT. RESULTS: A substantial reduction in bacterial counts was observed in all 3 groups when comparing S1 with S2 (99.95%, 98.93%, and 98.90% in the open-ended, closed-ended, and TruNatomy needle groups, respectively) (P < .01). No significant differences were observed between groups for bacterial reduction in the full and apical canal (P > .05). There were no intergroup differences in the amount of accumulated hard tissue debris either (P > .05). The open-ended needle group showed significantly more specimens with quantitative real-time polymerase chain reaction negative results for bacteria in S3 than TruNatomy (P < .05). CONCLUSION: When used up to an appropriate insertion depth, the 3 needle types result in similar antibacterial and cleaning performance, provided variables such as needle size and irrigant type, volume and flow rate are controlled. Exclusive analysis of the apical segment, including the isthmus, revealed that the open-ended needle yielded more cases negative for bacteria.


Asunto(s)
Cavidad Pulpar , Desinfección , Agujas , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Hipoclorito de Sodio , Microtomografía por Rayos X , Humanos , Agujas/microbiología , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Hipoclorito de Sodio/uso terapéutico , Hipoclorito de Sodio/farmacología , Irrigantes del Conducto Radicular/administración & dosificación , Irrigantes del Conducto Radicular/uso terapéutico , Desinfección/métodos , Cavidad Pulpar/microbiología , Diseño de Equipo , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Diente Molar/microbiología
7.
J Endod ; 50(10): 1478-1483, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39033800

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the efficacy of different irrigation needles and passive ultrasonic activation in removing Ca(OH)2 from an endodontic model that duplicated a root canal configuration of a human natural tooth. METHODS: An extracted human maxillary premolar was subjected to root canal preparation and scanned with microcomputed tomography. A 3-dimensional reconstruction model of the natural tooth was printed to endodontic models using a polyjet printer. The root canals of the models were filled with Ca(OH)2 paste and divided into 2 groups based on the irrigation protocol: conventional syringe-needle irrigation (conventional group) and passive ultrasonic irrigation (PUI) group. Each group was subdivided into 3 groups (n = 10) according to the type of needle: half-cut, side-vented, and TruNatomy irrigation needle. Microcomputed tomographyimaging was used to assess the percentage of reduction of Ca(OH)2. Data were analyzed using two-way analysis of variance test (α = .05). RESULTS: The side-vented and TruNatomy irrigation needles showed significantly higher percentage reductions than the half-cut needle (P < .05) in the conventional irrigation group. The PUI group showed significantly higher percentage reductions of Ca(OH)2 than the conventional group regardless of the type of needle (P < .05). However, no significant difference was found among the needles in the PUI group. CONCLUSIONS: The type of irrigation needle and the use of PUI influenced the removal efficacy of Ca(OH)2. PUI enhanced the removal of Ca(OH)2 regardless of the type of irrigation needle.


Asunto(s)
Hidróxido de Calcio , Agujas , Impresión Tridimensional , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Irrigación Terapéutica , Microtomografía por Rayos X , Humanos , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Irrigantes del Conducto Radicular/administración & dosificación , Preparación del Conducto Radicular/instrumentación , Preparación del Conducto Radicular/métodos , Ultrasonido , Modelos Dentales , Cavidad Pulpar/diagnóstico por imagen
8.
J Contemp Dent Pract ; 25(4): 331-334, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38956847

RESUMEN

AIM: The aim of the current study was to evaluate the penetration depth and smear layer removal of root canal irrigant using various irrigation activation techniques. MATERIALS AND METHODS: In this investigation, sixty single-rooted premolars extracted for orthodontic purposes were chosen. Diamond burs were used to create an access cavity, and #10 K-file was used to determine the patency. About sixty samples were divided into the following three groups (20 samples in each group), group I: Irrigation with conventional needle, group II: Activation of EndoVac system, group III: Passive ultrasonic irrigation (PUI). The efficacy of the smear layer was assessed using a scanning electron microscopy at a ×2000 magnification. One-way ANOVA was used to record and analyze the data. All statistical analyses were performed with a significance level of p < 0.05. RESULTS: At coronal third, the maximum smear layer was removed in group II (1.26 ± 0.02) followed by group III (1.84 ± 0.16) and group I (2.89 ± 0.21). At middle third, smear layer removal was maximum in group I (1.18 ± 0.10) followed by group III (1.72 ± 0.09) and group I (2.66 ± 0.18). At apical third, the more smear layer was removed in group II (1.02 ± 0.01) followed by group III (1.58 ± 0.08) and group I (2.38 ± 0.06). There was a highly significant difference found between the three different irrigation systems at all three levels (p < 0.001). CONCLUSION: In conclusion, every irrigation device that was evaluated was successful in removing the smear layer from the root canal. However, the EndoVac system group removed a greater amount of smear layer compared with PUI and conventional needle group. CLINICAL SIGNIFICANCE: With the goal of promoting cleaning that is beyond the ability of mechanical devices, irrigation is a crucial part of root canal therapy. If an efficient irrigation delivery system is used, the irrigants can reach the working length (WL). This type of distribution system needs to provide a suitable amount of irrigants up to the WL, as well as have enough flow and be effective at debriding the entire canal system. How to cite this article: Pujari MD, Das M, Das A, et al. Assessment of Smear Layer Removal and Penetration Depth of Root Canal Irrigant Using Different Irrigation Activation Systems: A Comparative Study. J Contemp Dent Pract 2024;25(4):331-334.


Asunto(s)
Microscopía Electrónica de Rastreo , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Capa de Barro Dentinario , Irrigación Terapéutica , Irrigantes del Conducto Radicular/administración & dosificación , Humanos , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Preparación del Conducto Radicular/métodos , Preparación del Conducto Radicular/instrumentación , Diente Premolar , Cavidad Pulpar , Técnicas In Vitro
9.
World J Urol ; 42(1): 420, 2024 Jul 18.
Artículo en Inglés | MEDLINE | ID: mdl-39026102

RESUMEN

PURPOSE: To report real-time IRP and FR while performing flexible ureteroscopy in porcine kidney model utilizing LithoVue™ Elite (Boston Scientific®) with different irrigation systems, including automated pumps. METHODS: Using an ex-vivo model of porcine kidney, IRPs were measured with LithoVue Elite. Ureteroscopic settings (US) were tested with all permutations of irrigation methods (IM), working channel occupant (WCO), and ureteral access sheaths (UAS). IMs included: Single Action Pumping System (SAPS™, Boston Scientific), Thermedx FluidSmart™ (Stryker®), and ENDOMAT™ (Karl Storz®). Pumps were tested at 50, 100, and 150 mmHg. WCOs included a 1.9Fr zero-tip basket, 200 µm, and 365 µm laser fibers. UASs utilized 11/13Fr and 12/14Fr 36 cm. RESULTS: 84 different US were tested (252 experiments). ENDOMAT had higher IRP but the same FR as Thermedx at the same US for 50 and 100 mmHg (p < 0.01). SAPS had higher IRP and FR than pumps in all US studies (p < 0.01). There was positive correlation between pressure set by the pump and both IRP and FR (rho > 0.9). As the diameter of the WCO increased, lower IRP and FR were observed with the pumps (p < 0.01). With SAPS, IRP was similar regardless of WCO, but FR was decreased with the increased diameter of WCO (p = 0.81 and p < 0.01, respectively). There was significantly higher IRP when using 11/13Fr UAS than 12/14Fr (p < 0.01). CONCLUSION: IRP was higher with SAPS than automated pumps. ENDOMAT showed higher IRP than Thermedx when under 150 mmHg. IRP and FR increase with higher pump pressure and decrease with larger diameter WCO. Likewise, a larger UAS significantly reduced IRP.


Asunto(s)
Riñón , Presión , Irrigación Terapéutica , Ureteroscopía , Animales , Porcinos , Irrigación Terapéutica/instrumentación , Ureteroscopía/instrumentación , Riñón/fisiología , Diseño de Equipo , Ureteroscopios
11.
Clin Exp Dent Res ; 10(3): e912, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38881230

RESUMEN

OBJECTIVES: Self-performed oral hygiene is essential for preventing dental caries, periodontal, and peri-implant diseases. Oral irrigators are adjunctive oral home care aids that may benefit oral health. However, the effects of oral irrigation on oral health, its role in oral home care, and its mechanism of action are not fully understood. A comprehensive search of the literature revealed no existing broad scoping reviews on oral irrigators. Therefore, this study aimed to provide a comprehensive systematic review of the literature on oral irrigation devices and identify evidence gaps. METHODS: The Joanna Briggs Institute and Preferred Reporting Items for Systematic reviews and Meta-Analyses extension for Scoping Reviews guidelines were utilized to prepare the review. Four databases and eight gray literature sources were searched for English publications across any geographical location or setting. RESULTS: Two hundred and seventy-five sources were included, predominantly from scientific journals and academic settings. Most studies originated from North America. Research primarily involved adults, with limited studies in children and adolescents. Oral irrigation was safe and well-accepted when used appropriately. It reduced periodontal inflammation, potentially by modulating the oral microbiota, but further research needs to clarify its mechanism of action. Promising results were reported in populations with dental implants and special needs. Patient acceptance appeared high, but standardized patient-reported outcome measures were rarely used. Anti-inflammatory benefits occurred consistently across populations and irrigant solutions. Plaque reduction findings were mixed, potentially reflecting differences in study designs and devices. CONCLUSIONS: Oral irrigators reduce periodontal inflammation, but their impact on plaque removal remains unclear. Well-designed, sufficiently powered trials of appropriate duration need to assess the clinical, microbiological, and inflammatory responses of the periodontium to oral irrigation, particularly those with periodontitis, dental implants, and special needs. Patient-reported outcome measures, costs, caries prevention, and environmental impact of oral irrigation need to be compared to other oral hygiene aids.


Asunto(s)
Higiene Bucal , Irrigación Terapéutica , Humanos , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Higiene Bucal/métodos , Salud Bucal , Caries Dental/prevención & control , Enfermedades Periodontales/prevención & control
12.
Urolithiasis ; 52(1): 86, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869637

RESUMEN

Ho: YAG laser lithotripsy is widely used for urinary stone treatment, but concerns persist regarding its thermal effects on renal tissues. This study aimed to monitor intrarenal temperature changes during kidney stone treatment using retrograde intrarenal surgery with Ho: YAG laser. Fifteen patients were enrolled. Various laser power settings (0.8 J/10 Hz, 1.2 J/12 Hz) and irrigation modes (10 cc/min, 15 cc/min, 20 cc/min, gravity irrigation, and manual pump irrigation) were used. A sterile thermal probe was attached to a flexible ureterorenoscope and delivered into the calyceal system via the ureteral access sheath. Temperature changes were recorded with a T-type thermal probe with ± 0.1 °C accuracy. Laser power significantly influenced mean temperature, with a 4.981 °C difference between 14 W and 8 W laser power (p < 0.001). The mean temperature was 2.075 °C higher with gravity irrigation and 2.828 °C lower with manual pump irrigation (p = 0.038 and p = 0.005, respectively). Body mass index, laser power, irrigation model, and operator duty cycle explained 49.5% of mean temperature variability (Adj. R2 = 0.495). Laser power and operator duty cycle positively impacted mean temperature, while body mass index and specific irrigation models affected it negatively. Laser power and irrigation rate are critical for intrarenal temperature during Ho: YAG laser lithotripsy. Optimal settings and irrigation strategies are vital for minimizing thermal injury risk. This study underscores the need for ongoing research to understand and mitigate thermal effects during laser lithotripsy.


Asunto(s)
Cálculos Renales , Riñón , Láseres de Estado Sólido , Litotripsia por Láser , Humanos , Proyectos Piloto , Litotripsia por Láser/métodos , Litotripsia por Láser/instrumentación , Cálculos Renales/cirugía , Cálculos Renales/terapia , Masculino , Persona de Mediana Edad , Femenino , Láseres de Estado Sólido/uso terapéutico , Riñón/cirugía , Riñón/fisiopatología , Adulto , Anciano , Temperatura Corporal , Monitoreo Intraoperatorio/métodos , Monitoreo Intraoperatorio/instrumentación , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación
13.
Trials ; 25(1): 380, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38867301

RESUMEN

BACKGROUND: Maintaining venous access is of great clinical importance. Running a slow continuous infusion to keep the vein open (KVO) is often used in peripheral intravenous catheters (PIVCs). Previous studies have compared the effects of intermittent flushing and continuous infusion via peripherally inserted central catheters (PICCs). In this study, we applied KVO to central venous catheters (CVCs) and compared the occlusion rate of this technique with that of the intermittent flushing technique. METHOD: This is a randomized controlled trial of 14 hospitals in China. A total of 250 patients will be recruited in this study, and they will be randomized at a 1:1 ratio. After study inclusion, patients who will undergo CVC insertion will receive intermittent flushing with prefilled saline syringes (control group) or KVO infusion with elastic pumps (test group). All the catheters will be checked for patency by scoping Catheter Injection and Aspiration (CINAS) Classification on Days 3 and 7. The primary outcome is the rate of catheter occlusion in 7 days. Patients will be followed up until 9 days after CVC insertion, catheter occlusion, or catheter removal. The secondary outcomes are the rate of catheter occlusion in 3 days, nurse satisfaction, cost-effectiveness, adverse event rate, catheter-related bloodstream infection rate, catheter-related thrombosis rate, extravasation rate, phlebitis rate, and catheter migration. DISCUSSION: We expect that the trial will generate findings that can provide an evidence-based basis for the improvement and optimization of clinical catheter flushing techniques. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR2200064007. Registered on 23 September 2022. https://www.chictr.org.cn/showproj.html?proj=177311 .


Asunto(s)
Obstrucción del Catéter , Cateterismo Venoso Central , Catéteres Venosos Centrales , Estudios Multicéntricos como Asunto , Humanos , Catéteres Venosos Centrales/efectos adversos , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/instrumentación , Cateterismo Venoso Central/métodos , Obstrucción del Catéter/etiología , China , Estudios de Equivalencia como Asunto , Persona de Mediana Edad , Adulto , Masculino , Resultado del Tratamiento , Femenino , Factores de Tiempo , Ensayos Clínicos Controlados Aleatorios como Asunto , Cateterismo Periférico/efectos adversos , Cateterismo Periférico/instrumentación , Cateterismo Periférico/métodos , Catéteres de Permanencia/efectos adversos , Infusiones Intravenosas , Irrigación Terapéutica/efectos adversos , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Anciano
14.
Odontology ; 112(4): 1248-1256, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38703256

RESUMEN

Understanding the apical pressure and irrigant flow patterns in root canals is crucial for safe and effective irrigation. Therefore, this study aimed to assess the flow characteristics of irrigants in root canal models with varying tapers during final irrigation by employing various needle designs, including a back-to-back double-side-vented needle, through computational fluid dynamics. The root canal model was configured as a closed geometrical cone with a simulated apical zone (size 30) and features tapers of 4%, 6%, and 8%. Three needle types-open-ended needle (OEN), single side-vented needle (SSVN), and double side-vented needle (DSVN)-were investigated. The results indicated that for the 4% taper models, the open-ended needle generated the maximum apical pressure, followed by the double side-vented needle and the single side-vented needle. However, in the 6% and 8% tapering root canal models, the double-side-vented needle applied the lowest maximum apical pressure. Consequently, the DSVN can pose a risk for irrigant extrusion in minimally prepared canals due to heightened apical pressure. In wider canals, the DSVN exhibited lower apical pressure. The maximum irrigant replacement was observed with OEN compared to that of the closed-ended group for both flow rates. Additionally, compared with OENs, closed-ended needles exhibited nonuniform and lower shear wall stress.


Asunto(s)
Cavidad Pulpar , Diseño de Equipo , Hidrodinámica , Agujas , Irrigantes del Conducto Radicular , Preparación del Conducto Radicular , Humanos , Preparación del Conducto Radicular/instrumentación , Simulación por Computador , Irrigación Terapéutica/instrumentación
15.
Clin Implant Dent Relat Res ; 26(4): 724-733, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38802889

RESUMEN

OBJECTIVE: To compare collected bone weight and the frequency of autologous bone harvesting from the flutes of surgical drills used for implant bed preparation using two different drilling techniques. A comparative evaluation of radiographic bone density and bone quality was also made. MATERIALS AND METHODS: A randomized clinical trial was made of 66 dental implants in patients with a single posterior edentulous site. The compared drilling techniques were high-speed drilling with irrigation (control group) and low-speed drilling without irrigation (test group). The bone collected in both groups was dried and weighed with a precise electronic balance. The frequency of harvesting was calculated. The median radiographic bone density of each implant site was measured using cone-beam computed tomography (CBCT) pixel values. Patient sex, age, implant position and dimensions, as well as the last drill diameter were analyzed as independent variables. The level of significance was 5%. RESULTS: The harvesting of bone chips from drill flutes proved possible in 51.5% of the procedures in the control group and in 100% in the test group (p < 0.001). There were also statistically significant differences in bone weight between the control group (6.7 ± 10.6 mg) and the test group (41.9 ± 30.3 mg) (p < 0.001). The CBCT pixel values were directly correlated with the collected bone weight in both groups. The median radiographic bone density, arch and last drill diameter were significantly associated with harvesting bone frequency and collected bone weight (p < 0.05). CONCLUSIONS: Our findings suggest that the frequency and weight of autologous bone harvested from drills are greater with low-speed drilling without irrigation than with high-speed drilling with irrigation. Radiographic bone density, arch and last drill diameter also significantly influenced the harvesting outcomes.


Asunto(s)
Densidad Ósea , Trasplante Óseo , Tomografía Computarizada de Haz Cónico , Irrigación Terapéutica , Recolección de Tejidos y Órganos , Humanos , Masculino , Femenino , Persona de Mediana Edad , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos , Trasplante Óseo/métodos , Recolección de Tejidos y Órganos/métodos , Recolección de Tejidos y Órganos/instrumentación , Implantación Dental Endoósea/métodos , Adulto , Anciano , Implantes Dentales , Trasplante Autólogo
16.
Childs Nerv Syst ; 40(8): 2373-2384, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38801444

RESUMEN

OBJECTIVE: Intraventricular hemorrhage (IVH) of prematurity occurs in 20-38% of infants born < 28 weeks gestational age and 15% of infants born in 28-32 weeks gestational age. Treatment has evolved from conservative management and CSF diversion of temporizing and shunting procedures to include strategies aimed at primarily clearing intraventricular blood products. Neuroendoscopic lavage (NEL) aims to decrease the intraventricular blood burden under the same anesthetic as temporizing CSF diversion measures in cases of hydrocephalus from IVH of prematurity. Given the variety of neuroendoscopes, we sought to review the literature and practical considerations to help guide neuroendoscope selection when planning NEL. METHODS: We conducted a systematic review of the literature on neuroendoscopic lavage in IVH of prematurity to examine data on the choice of neuroendoscope and outcomes regarding shunt rate. We then collected manufacturer data on neuroendoscopic devices, including inflow and outflow mechanisms, working channel specifications, and tools compatible with the working channel. We paired this information with the advantages and disadvantages reported in the literature and observations from the experiences of pediatric neurosurgeons from several institutions to provide a pragmatic evaluation of international clinical experience with each neuroendoscope in NEL. RESULTS: Eight studies were identified; four neuroendoscopes have been used for NEL as reported in the literature. These include the Karl Storz Flexible Neuroendoscope, LOTTA® system, GAAB system, and Aesculap MINOP® system. The LOTTA® and MINOP® systems were similar in setup and instrument options. Positive neuroendoscope features for NEL include increased degrees of visualization, better visualization with the evolution of light and camera sources, the ability to sterilize with autoclave processes, balanced inflow and outflow mechanisms via separate channels, and a working channel. Neuroendoscope disadvantages for NEL may include special sterilization requirements, large outer diameter, and limitations in working channels. CONCLUSIONS: A neuroendoscope integrating continuous irrigation, characterized by measured inflow and outflow via separate channels and multiple associated instruments, appears to be the most commonly used technology in the literature. As neuroendoscopes evolve, maximizing clear visualization, adequate inflow, measured outflow, and large enough working channels for paired instrumentation while minimizing the footprint of the outer diameter will be most advantageous when applied for NEL in premature infants.


Asunto(s)
Recien Nacido Prematuro , Neuroendoscopía , Irrigación Terapéutica , Humanos , Neuroendoscopía/métodos , Neuroendoscopía/instrumentación , Recién Nacido , Irrigación Terapéutica/métodos , Irrigación Terapéutica/instrumentación , Hemorragia Cerebral/cirugía , Hemorragia Cerebral Intraventricular/cirugía , Neuroendoscopios , Enfermedades del Prematuro/cirugía , Enfermedades del Prematuro/terapia
17.
Compend Contin Educ Dent ; 45(Suppl 1): 20, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38781414

RESUMEN

The objective of this in vitro study was to compare the area of oral biofilm removal by the Philips Sonicare Quad Stream (PSQS) nozzle (used on a Philips® Sonicare® Power Flosser) and a traditional oral irrigator with a standard nozzle (TOIS) when used per the directions for use (DFU) instructions for both devices.


Asunto(s)
Biopelículas , Irrigación Terapéutica , Humanos , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos , Técnicas In Vitro , Diseño de Equipo
18.
Injury ; 55(6): 111590, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38701674

RESUMEN

OBJECTIVE: To compare the bone healing effects of percutaneously delivered bone marrow aspirate concentrate (BMC) versus reamer irrigator aspirator (RIA) suspension in a validated preclinical canine ulnar nonunion model. We hypothesized that BMC would be superior to RIA in inducing bone formation across a nonunion site after percutaneous application. The null hypothesis was that BMC and RIA would be equivalent. METHODS: A bilateral ulnar nonunion model (n= 6; 3 matched pairs) was created. Eight weeks after segmental ulnar ostectomy, RIA from the ipsilateral femur and BMC from the proximal humerus were harvested and percutaneously administered into either the left or right ulnar defect. The same volume (3 ml) of RIA suspension and BMC were applied on each side. Eight weeks after treatment, the dogs were euthanized, and the nonunions were evaluated using radiographic, biomechanical, and histologic assessments. RESULTS: All dogs survived for the intended study duration, formed radiographic nonunions 8 weeks after segmental ulnar ostectomy, and underwent the assigned percutaneous treatment. Radiographic and macroscopic assessments of bone healing at the defect sites revealed superior bridging-callous formation in BMC-treated nonunions. Histologic analyses revealed greater amount of bony bridging and callous formation in the BMC group. Biomechanical testing of the treated nonunions did not reveal any significant differences. CONCLUSION: Bone marrow aspirate concentrate (BMC) had important advantages over Reamer Irrigator Aspirator (RIA) suspension for percutaneous augmentation of bone healing in a validated preclinical canine ulnar nonunion model based on clinically relevant radiographic and histologic measures of bone formation.


Asunto(s)
Trasplante de Médula Ósea , Modelos Animales de Enfermedad , Curación de Fractura , Fracturas no Consolidadas , Irrigación Terapéutica , Animales , Perros , Fracturas no Consolidadas/terapia , Trasplante de Médula Ósea/métodos , Curación de Fractura/fisiología , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos , Fracturas del Cúbito/cirugía , Fracturas del Cúbito/terapia
19.
Br J Oral Maxillofac Surg ; 62(5): 459-463, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38670905

RESUMEN

Bone removal is commonly used in the extraction of third molars and the heat generated during the process can interfere with the repair of bone. The aim of this study was to evaluate the temperature variation presented in bone removal performed with a high-speed turbine (400000 rpm), implant motor with straight piece (100000 rpm), low-speed micromotor (20000 rpm) and piezoelectric saw (30 kHz) in pig mandibles. For this, bone removal was carried out around 20 posterior teeth, under constant saline solution irrigation with a syringe and needle. In addition, the time required to perform bone removal was recorded. The results indicated a mean (SD) temperature variation of 0.96 °C (0.6 °C) for the high-speed turbine, 1.38 °C (0.5 °C) with the implant motor, 2.22 °C (0.7 °C) for the low-speed micromotor and 2.90 °C (1.3 °C) for the piezoelectric saw. The conventional variance was calculated discounting the variation of time used for bone removal around the teeth. There was a statistically significant difference in temperature variation between the high-speed turbine vs the micromotor (p = 0.009) and the high speed micromotor vs the piezoelectric saw (p = 0.04). We conclude that there is a statistically significant difference in temperature variation between the instruments used in oral and maxillofacial surgery, with higher rotation speeds resulting in the lowest temperature variations and a reduced surgical time.


Asunto(s)
Mandíbula , Tercer Molar , Piezocirugía , Temperatura , Extracción Dental , Animales , Tercer Molar/cirugía , Porcinos , Mandíbula/cirugía , Piezocirugía/instrumentación , Irrigación Terapéutica/instrumentación , Osteotomía/instrumentación , Osteotomía/métodos , Factores de Tiempo , Equipo Dental de Alta Velocidad , Tempo Operativo , Diseño de Equipo , Solución Salina , Calor , Agujas , Jeringas
20.
J Oral Maxillofac Surg ; 82(7): 756-760, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38621667

RESUMEN

Temporomandibular joint internal disorders commonly present with limited mouth opening and pain. Treatment options range from invasive surgical procedures to minimally invasive interventions. This technical note aims to introduce a modification to the arthrocentesis technique in which a pressure infusion cuff (VBM Classic Infusor, Medizintechnik GmbH, Germany) is used for irrigation instead of syringes or peristaltic pumps. A pressure infusion cuff (bag) is an inflatable bag with a hand pump and a sphygmomanometer that allows monitorization of the pressure, and it is intended to apply pressure on intravenous fluid bags to assist with rapid infusion of fluids. This allows the operator to maintain an efficient and stable flow pressure throughout the procedure while avoiding occupational hand and wrist problems resulting from manual irrigation with syringes. Furthermore, pressure monitoring, as read on the sphygmomanometer of the cuff, facilitates the manipulation of the needles and adjustment of the pressure should the patient experience discomfort. This increases the patient's compliance, physician's comfort, and allows the collection of quantitative data in clinical studies.


Asunto(s)
Artrocentesis , Trastornos de la Articulación Temporomandibular , Humanos , Artrocentesis/métodos , Artrocentesis/instrumentación , Trastornos de la Articulación Temporomandibular/cirugía , Presión , Diseño de Equipo , Irrigación Terapéutica/instrumentación , Irrigación Terapéutica/métodos
SELECCIÓN DE REFERENCIAS