Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Am J Respir Crit Care Med ; 202(4): 524-534, 2020 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-32510976

RESUMEN

Rationale: Adverse events have limited the use of bronchial thermoplasty (BT) in severe asthma.Objectives: We sought to evaluate the effectiveness and safety of using 129Xe magnetic resonance imaging (129Xe MRI) to prioritize the most involved airways for guided BT.Methods: Thirty subjects with severe asthma were imaged with volumetric computed tomography and 129Xe MRI to quantitate segmental ventilation defects. Subjects were randomized to treatment of the six most involved airways in the first session (guided group) or a standard three-session BT (unguided). The primary outcome was the change in Asthma Quality of Life Questionnaire score from baseline to 12 weeks after the first BT for the guided group compared with after three treatments for the unguided group.Measurements and Main Results: There was no significant difference in quality of life after one guided compared with three unguided BTs (change in Asthma Quality of Life Questionnaire guided = 0.91 [95% confidence interval, 0.28-1.53]; unguided = 1.49 [95% confidence interval, 0.84-2.14]; P = 0.201). After one BT, the guided group had a greater reduction in the percentage of poorly and nonventilated lung from baseline when compared with unguided (-17.2%; P = 0.009). Thirty-three percent experienced asthma exacerbations after one guided BT compared with 73% after three unguided BTs (P = 0.028).Conclusions: Results of this pilot study suggest that similar short-term improvements can be achieved with one BT treatment guided by 129Xe MRI when compared with standard three-treatment-session BT with fewer periprocedure adverse events.


Asunto(s)
Asma/cirugía , Termoplastia Bronquial/métodos , Imagen por Resonancia Magnética/métodos , Cirugía Asistida por Computador , Isótopos de Xenón/uso terapéutico , Adulto , Termoplastia Bronquial/efectos adversos , Método Doble Ciego , Femenino , Humanos , Masculino , Persona de Mediana Edad , Proyectos Piloto , Calidad de Vida , Índice de Severidad de la Enfermedad , Resultado del Tratamiento
2.
IEEE Trans Med Imaging ; 38(5): 1240-1250, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30475715

RESUMEN

Hyperpolarized (HP) gas (e.g., 3He or 129Xe) dynamic MRI could visualize the lung ventilation process, which provides characteristics regarding lung physiology and pathophysiology. Compressed sensing (CS) is generally used to increase the temporal resolution of such dynamic MRI. Nevertheless, the acceleration factor of CS is constant, which results in difficulties in precisely observing and/or measuring dynamic ventilation process due to bifurcating network structure of the lung. Here, an adaptive strategy is proposed to highly undersample pulmonary HP dynamic k-space data, according to the characteristics of both lung structure and gas motion. After that, a valid reconstruction algorithm is developed to reconstruct dynamic MR images, considering the low-rank, global sparsity, gas-inflow effects, and joint sparsity. Both the simulation and the in vivo results verify that the proposed approach outperforms the state-of-the-art methods both in qualitative and quantitative comparisons. In particular, the proposed method acquires 33 frames within 6.67 s (more than double the temporal resolution of the recently proposed strategy), and achieves high-image quality [the improvements are 29.63%, 3.19%, 2.08%, and 13.03% regarding the mean absolute error (MAE), structural similarity index (SSIM), quality index based on local variance (QILV), and contrast-to-noise ratio (CNR) comparisons]. This provides accurate structural and functional information for early detection of obstructive lung diseases.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Pulmón/diagnóstico por imagen , Pulmón/fisiología , Imagen por Resonancia Magnética/métodos , Algoritmos , Medios de Contraste/uso terapéutico , Humanos , Procesamiento de Señales Asistido por Computador , Isótopos de Xenón/uso terapéutico
3.
Magn Reson Med ; 79(5): 2597-2606, 2018 05.
Artículo en Inglés | MEDLINE | ID: mdl-28921655

RESUMEN

PURPOSE: To develop and optimize a rapid dynamic hyperpolarized 129 Xe ventilation (DXeV) MRI protocol and investigate the feasibility of capturing pulmonary signal-time curves in human lungs. THEORY AND METHODS: Spiral k-space trajectories were designed with the number of interleaves Nint = 1, 2, 4, and 8 corresponding to voxel sizes of 8 mm, 5 mm, 4 mm, and 2.5 mm, respectively, for field of view = 15 cm. DXeV images were acquired from a gas-flow phantom to investigate the ability of Nint = 1, 2, 4, and 8 to capture signal-time curves. A finite element model was constructed to investigate gas-flow dynamics corroborating the experimental signal-time curves. DXeV images were also carried out in six subjects (three healthy and three chronic obstructive pulmonary disease subjects). RESULTS: DXeV images and numerical modelling of signal-time curves permitted the quantification of temporal and spatial resolutions for different numbers of spiral interleaves. The two-interleaved spiral (Nint = 2) was found to be the most time-efficient to obtain DXeV images and signal-time curves of whole lungs with a temporal resolution of 624 ms for 13 slices. Signal-time curves were well matched in three healthy volunteers. The Spearman's correlations of chronic obstructive pulmonary disease subjects were statistically different from three healthy subjects (P < 0.05). CONCLUSION: The Nint = 2 spiral demonstrates the successful acquisition of DXeV images and signal-time curves in healthy subjects and chronic obstructive pulmonary disease patients. Magn Reson Med 79:2597-2606, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Interpretación de Imagen Asistida por Computador/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/administración & dosificación , Administración por Inhalación , Adulto , Simulación por Computador , Femenino , Humanos , Masculino , Fantasmas de Imagen , Enfermedad Pulmonar Obstructiva Crónica/diagnóstico por imagen , Isótopos de Xenón/farmacocinética , Isótopos de Xenón/uso terapéutico
4.
Magn Reson Med ; 78(4): 1306-1315, 2017 10.
Artículo en Inglés | MEDLINE | ID: mdl-28940334

RESUMEN

PURPOSE: The purpose of this work was to accurately characterize the spectral properties of hyperpolarized 129 Xe in patients with idiopathic pulmonary fibrosis (IPF) compared to healthy volunteers. METHODS: Subjects underwent hyperpolarized 129 Xe breath-hold spectroscopy, during which 38 dissolved-phase free induction decays (FIDs) were acquired after reaching steady state (echo time/repetition time = 0.875/50 ms; bandwidth = 8.06 kHz; flip angle≈22 °). FIDs were averaged and then decomposed into multiple spectral components using time-domain curve fitting. The resulting amplitudes, frequencies, line widths, and starting phases of each component were compared among groups using a Mann-Whitney-Wilcoxon U test. RESULTS: Three dissolved-phase resonances, consisting of red blood cells (RBCs) and two barrier compartments, were consistently identified in all subjects. In subjects with IPF relative to healthy volunteers, the RBC frequency was 0.70 parts per million (ppm) more negative (P = 0.05), the chemical shift of barrier 2 was 0.6 ppm more negative (P = 0.009), the line widths of both barrier peaks were ∼2 ppm narrower (P < 0.001), and the starting phase of barrier 1 was 20.3 ° higher (P = 0.01). Moreover, the ratio RBC:barriers was reduced by 52.9% in IPF (P < 0.001). CONCLUSIONS: The accurate decomposition of 129 Xe spectra not only has merit for developing a global metric of pulmonary function, but also provides necessary insights to optimize phase-sensitive methods for imaging 129 Xe gas transfer. Magn Reson Med 78:1306-1315, 2017. © 2016 International Society for Magnetic Resonance in Medicine.


Asunto(s)
Fibrosis Pulmonar Idiopática/diagnóstico por imagen , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/uso terapéutico , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Procesamiento de Señales Asistido por Computador , Adulto Joven
5.
Magn Reson Med ; 75(6): 2227-34, 2016 06.
Artículo en Inglés | MEDLINE | ID: mdl-27080441

RESUMEN

PURPOSE: Upon inhalation, xenon diffuses into the bloodstream and is transported to the brain, where it dissolves in various compartments of the brain. Although up to five chemically distinct peaks have been previously observed in (129) Xe rat head spectra, to date only three peaks have been reported in the human head. This study demonstrates high resolution spectroscopy and chemical shift imaging (CSI) of (129) Xe dissolved in the human head at 1.5 Tesla. METHODS: A (129) Xe radiofrequency coil was built in-house and (129) Xe gas was polarized using spin-exchange optical pumping. Following the inhalation of (129) Xe gas, NMR spectroscopy was performed with spectral resolution of 0.033 ppm. Two-dimensional CSI in all three anatomical planes was performed with spectral resolution of 2.1 ppm and voxel size 20 mm × 20 mm. RESULTS: Spectra of hyperpolarized (129) Xe dissolved in the human head showed five distinct peaks at 188 ppm, 192 ppm, 196 ppm, 200 ppm, and 217 ppm. Assignment of these peaks was consistent with earlier studies. CONCLUSION: High resolution spectroscopy and CSI of hyperpolarized (129) Xe dissolved in the human head has been demonstrated. For the first time, five distinct NMR peaks have been observed in (129) Xe spectra from the human head in vivo. Magn Reson Med 75:2227-2234, 2016. © 2016 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.


Asunto(s)
Encéfalo/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Neuroimagen/métodos , Isótopos de Xenón/uso terapéutico , Adulto , Diseño de Equipo , Humanos , Imagen por Resonancia Magnética/instrumentación , Masculino , Isótopos de Xenón/administración & dosificación
6.
Magn Reson Med ; 75(4): 1434-43, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25980630

RESUMEN

PURPOSE: We sought to develop and test a clinically feasible 1-point Dixon, three-dimensional (3D) radial acquisition strategy to create isotropic 3D MR images of (129)Xe in the airspaces, barrier, and red blood cells (RBCs) in a single breath. The approach was evaluated in healthy volunteers and subjects with idiopathic pulmonary fibrosis (IPF). METHODS: A calibration scan determined the echo time at which (129)Xe in RBCs and barrier were 90° out of phase. At this TE, interleaved dissolved and gas-phase images were acquired using a 3D radial acquisition and were reconstructed separately using the NUFFT algorithm. The dissolved-phase image was phase-shifted to cast RBC and barrier signal into the real and imaginary channels such that the image-derived RBC:barrier ratio matched that from spectroscopy. The RBC and barrier images were further corrected for regional field inhomogeneity using a phase map created from the gas-phase (129)Xe image. RESULTS: Healthy volunteers exhibited largely uniform (129)Xe-barrier and (129)Xe-RBC images. By contrast, (129)Xe-RBC images in IPF subjects exhibited significant signal voids. These voids correlated qualitatively with regions of fibrosis visible on CT. CONCLUSIONS: This study illustrates the feasibility of acquiring single-breath, 3D isotropic images of (129)Xe in the airspaces, barrier, and RBCs using a 1-point Dixon 3D radial acquisition.


Asunto(s)
Eritrocitos/fisiología , Imagenología Tridimensional/métodos , Pulmón/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Isótopos de Xenón/uso terapéutico , Adulto , Anciano , Algoritmos , Eritrocitos/citología , Femenino , Humanos , Pulmón/irrigación sanguínea , Pulmón/fisiología , Masculino , Persona de Mediana Edad , Adulto Joven
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...