Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.614
Filtrar
1.
BMC Ophthalmol ; 24(1): 401, 2024 Sep 09.
Artículo en Inglés | MEDLINE | ID: mdl-39251947

RESUMEN

BACKGROUND: To compare and evaluate objective and subjective clinical parameters between 0.05% cyclosporine nanoemulsion (CsN) and 0.15% hyaluronic acid (HA) administration in patients with mild-to-moderate dry eyes. METHODS: In this prospective, randomized, double-masked, single-center, and placebo-controlled parallel study, patients with mild-to-moderate dry eyes were randomly allocated to be treated with 0.05% CsN or 0.15% HA twice daily. Patients were followed-up at 4, 8, and 12 weeks. Objective and subjective parameters were evaluated during each visit. RESULTS: A total of 35 patients were enrolled in this study. Compared with baseline, tear film break-up time and fluorescein staining scores at 4, 8, and 12 weeks significantly improved in the CsN group. However, the Schirmer I test showed no statistically significant change until week 12. Using the Symptom Assessment in Dry Eye (SANDE) score, both groups gradually showed significant improvement compared with baseline values. However, the Dry Eye-Related Quality-of-life Score Questionnaire (DEQS) showed no statistically significant change during the treatment period. CONCLUSIONS: Both 0.05% CsN and 0.15% HA administration twice a day effectively improved the objective signs and subjective symptoms of patients with mild-to-moderate dry eyes. However, patients treated with 0.05% CsN experienced greater and faster improvement.


Asunto(s)
Ciclosporina , Síndromes de Ojo Seco , Emulsiones , Ácido Hialurónico , Inmunosupresores , Soluciones Oftálmicas , Lágrimas , Humanos , Síndromes de Ojo Seco/tratamiento farmacológico , Síndromes de Ojo Seco/fisiopatología , Ciclosporina/administración & dosificación , Ciclosporina/uso terapéutico , Soluciones Oftálmicas/administración & dosificación , Femenino , Masculino , Estudios Prospectivos , Método Doble Ciego , Persona de Mediana Edad , Adulto , Ácido Hialurónico/administración & dosificación , Lágrimas/metabolismo , Lágrimas/fisiología , Inmunosupresores/administración & dosificación , Inmunosupresores/uso terapéutico , Calidad de Vida , Resultado del Tratamiento , Anciano
2.
Invest Ophthalmol Vis Sci ; 65(10): 15, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39110586

RESUMEN

Purpose: We determined interblink corneal surface-temperature decline and tear-film evaporation rates of localized tear breakup cold regions (LCRs) and localized tear unbroken warm regions (LWRs) of the corneal surface, as well as that of the overall average corneal surface. Methods: Each subject underwent 4 inter-day visits where the interblink corneal surface-temperature history of the right eye was measured using a FLIR A655sc infrared thermographer. Corneal surface temperature history was analyzed to determine the overall, LCR, and LWR temperature-decline rates. Evaporation rates of LCR and LWR regions were determined from the measured LCR and LWR temperature data using the physical model of Dursch et al. Results: Twenty subjects completed the study. Mean (SD) difference of LCR temperature-decline rate was -0.08 (0.07)°C/s faster than LWR (P < 0.0001). Similarly, evaporation rates of LCR and LWR were statistically different (P < 0.0001). At ambient temperature, mean LCR and LWR evaporation rates were 76% and 27% of pure water evaporation flux, respectively. There was no statistically significant difference between the inter-day measured temperature-decline rates and the interblink starting temperature. Conclusions: Significant differences in corneal temperature-decline rate and evaporation rate between LCR and LWR were quantified using infrared thermography. In agreement with literature, LCRs and LWRs correlate directly with fluorescein break-up areas and unbroken tear areas, respectively. Because lipid-evaporation protection is diminished in breakup areas, higher local evaporation rates and faster local cooling rates occur in LCRs relative to LWRs. Our results confirm this phenomenon clinically for the first time.


Asunto(s)
Parpadeo , Temperatura Corporal , Córnea , Lágrimas , Humanos , Lágrimas/fisiología , Lágrimas/química , Masculino , Adulto , Femenino , Córnea/fisiología , Parpadeo/fisiología , Temperatura Corporal/fisiología , Termografía/métodos , Adulto Joven , Regulación de la Temperatura Corporal/fisiología
3.
BMC Ophthalmol ; 24(1): 376, 2024 Aug 26.
Artículo en Inglés | MEDLINE | ID: mdl-39187788

RESUMEN

BACKGROUND: Warm compresses are the routine treatment for Meibomian gland dysfunction (MGD) in daily life, but in order to achieve satisfactory efficacy, the treatment needs to be sustained over a long time, which can have an impact on the patient compliance. A more convenient warm compresses will help improve the patient compliance. Therefore, the purpose of the study is to investigate the efficacy and safety of the disposable eyelid warming masks for treatment of dry eye disease (DED) due to MGD. METHODS: This was a randomized, controlled, non-masked, two-center clinical trial. One hundred and forty-four patients were treated by the masks or the hot towel twice daily for 12 weeks. Patients were evaluated at baseline, 4-week and 12-week visits for subjective symptoms, objective signs and safety assessments, including ocular symptom scores, ocular surface disease index (OSDI), tear break-up time (BUT), corneal fluorescein staining (CFS), Schirmer I test (SIT), meibum quality, meibum expressibility, and adverse events (AEs). RESULTS: A totle of 134 patients were followed in the study. The mean age of the masks group (14 males and 52 females) and the hot towel group (20 males and 48 females) was 43.7 ± 13.5 years and 39.5 ± 13.9 years, respectively. At 4-week visit, there were significant statistical differences in ocular symptom scores, OSDI and CFS between two groups (P < 0.05). Except for SIT, the treatment group showed a greater improvement in subjective symptoms and objective signs than the control group at 12-week visit. (P < 0.05). In addition, 40 AEs occurred in 27 patients (37.5%) in the treatment group, and 34 AEs occurred in 21 patients (29.17%) in the control group. No serious AEs were reported. CONCLUSIONS: The masks had a good efficacy and safety in the treatment of DED due to MGD, and might offer an attractive treatment option for some patients. TRIAL REGISTRATION: The study was registered at Chinese Clinical Trial Registry (ChiCTR1900025443) on August 26, 2019.


Asunto(s)
Síndromes de Ojo Seco , Disfunción de la Glándula de Meibomio , Humanos , Femenino , Masculino , Síndromes de Ojo Seco/terapia , Síndromes de Ojo Seco/fisiopatología , Persona de Mediana Edad , Disfunción de la Glándula de Meibomio/terapia , Adulto , Máscaras/efectos adversos , Glándulas Tarsales , Resultado del Tratamiento , Equipos Desechables , Anciano , Lágrimas/fisiología , Lágrimas/metabolismo , Hipertermia Inducida/instrumentación , Hipertermia Inducida/métodos , Hipertermia Inducida/efectos adversos
4.
Cont Lens Anterior Eye ; 47(5): 102169, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39025755

RESUMEN

PURPOSE: Vitamin D (VD) is a vitamin with anti-inflammatory and immunomodulatory effects. Several studies have shown that VD deficiency is associated with the incidence and severity of dry eye disease (DED) in humans. This meta-analysis compared signs and symptoms in patients with DED before and after VD supplementation. METHODS: Ten databases (PubMed, Cochrane, Web of science, Ovid, Embase, Scopus, CNKI, CSTJ, Wanfang, Sinomed) and four clinical trials registry websites (ISRCTN, CT, ICTRP, ICH GCP) were searched for studies on the efficacy of VD supplement in patients with DED that were published up to 2023 January. A total of 8 studies with 439 cases were included. Two reviewers independently assessed the quality of the literature and extracted data to calculate standard mean differences (SMD) for the Schirmer's test (SH test), tear film break-up time (TBUT), corneal fluorescein staining scores (CFSS, Oxford Scale, 0-5), lid hyperemia, ocular surface disease index (OSDI), and visual analogue pain scale (VAS). RESULTS: The analysis showed that VD supplementation improved tear production (SMD 1.43, 95% CI 0.81, 2.05, p = 0.000) and tear film stability (SMD 1.19, 95% CI 0.83, 1.55, p = 0.000) and reduced lid hyperemia (SMD -0.71, 95% CI -1.09, -0.32, p = 0.000) and OSDI (SMD -1.10, 95% CI -1.45, -0.74, p = 0.000), which is effective in alleviating the signs and symptoms of DED. CONCLUSIONS: VD supplementation could be an adjuvant treatment to alleviate the signs and symptoms of dry eye in the future. However, further studies regarding its most appropriate administration and dosage need to be conducted.


Asunto(s)
Suplementos Dietéticos , Síndromes de Ojo Seco , Vitamina D , Vitaminas , Síndromes de Ojo Seco/tratamiento farmacológico , Humanos , Vitamina D/administración & dosificación , Vitamina D/uso terapéutico , Vitaminas/administración & dosificación , Vitaminas/uso terapéutico , Lágrimas/metabolismo , Lágrimas/fisiología , Resultado del Tratamiento
6.
BMC Ophthalmol ; 24(1): 275, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970043

RESUMEN

BACKGROUND: To compare the repeatability and reproducibility of corneal and corneal epithelial thickness mapping using anterior segment optical coherence tomography (AS-OCT) according to tear film break-up time (TBUT). METHODS: The included eyes were divided into three subgroups according to TBUT (group 1: TBUT ≤ 5 s, group 2: 5 s < TBUT ≤ 10 s, and group 3: TBUT > 10 s). All eyes were imaged separately thrice by two operators to obtain the thickness maps (TMs) of the cornea and corneal epithelium based on spatial zones encompassing a 9-mm-diameter area. Each TM consisted of 25 areas. Intraoperator (repeatability) and interoperator (reproducibility) standard deviations (Sws), coefficients of variation (CoVs), and intraclass correlation coefficients (ICCs) among the tests were calculated and compared in all the areas. RESULTS: Altogether, 132 eyes of 67 subjects were included (50, 47, and 35 eyes in groups 1, 2, and 3; respectively). The ICCs of corneal epithelial thickness and corneal thickness were > 0.75 in most of the areas. Pairwise comparisons showed that AS-OCT exhibited lower repeatability in group 1 than in groups 2 and 3 (P < 0.05). However groups 2 and 3 showed similar results. Sws and CoVs of corneal epithelial thickness exhibited no significant interoperator differences. While no significant differences were observed in corneal thickness in most of the areas. CONCLUSIONS: TBUT significantly influences the repeatability of corneal and corneal epithelial thickness measurements. Poor tear film stability requires careful evaluation of corneal epithelial thickness.


Asunto(s)
Córnea , Lágrimas , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Femenino , Reproducibilidad de los Resultados , Masculino , Lágrimas/fisiología , Córnea/diagnóstico por imagen , Adulto , Persona de Mediana Edad , Epitelio Corneal/diagnóstico por imagen , Adulto Joven , Paquimetría Corneal/métodos , Anciano
7.
Int Ophthalmol ; 44(1): 297, 2024 Jun 29.
Artículo en Inglés | MEDLINE | ID: mdl-38951293

RESUMEN

BACKGROUND/OBJECTIVES: To evaluate the effect of topical cyclosporine A (CsA) 0.05% in patients with pterygium surgery using fibrin glue (FG). SUBJECTS/METHODS: Patients with primary nasal pterygium were retrospectically analyzed and categorized into two groups: Group 1 with 41 eyes from 38 patients as a control group and group 2 with 39 eyes from 36 patients who received topical CsA twice a day for 6 months. Patients were assessed for recurrence rate, tear film parameters, side effects, and complications at postoperative intervals of 1-7 days; 1st, 3rd, 6th and 12th months. The follow-up period was 1 year. RESULTS: The two groups were age (p = 0.934) and sex (p = 0.996) matched. CsA drop was discontinued in one patient due to burning sensation and conjunctival hyperemia after 1 week. There was no statistically significant difference between the mean preoperative and postoperative 1st year Schirmer I and tear break-up time (TBUT) values in group 1 (p = 0.136; p = 0.069). Although the difference between the mean preoperative and postoperative 1st year TBUT values in group 2 was not statistically different (p = 0.249), Schirmer I results were higher postoperatively (p = 0.003). There was no statistically significant difference between preoperative Schirmer (p = 0.496), postoperative Schirmer (p = 0.661), preoperative TBUT (p = 0.240) and postoperative TBUT (p = 0.238) results of the two groups. Recurrence was observed in only one patient from group 1. CONCLUSION: No recurrent pterygium cases were observed in group 2. Schirmer I values were higher postoperatively in group 2; thus,topical CsA treatment may improve lacrimal secretion and be effective after pterygium surgery with FG.


Asunto(s)
Ciclosporina , Adhesivo de Tejido de Fibrina , Inmunosupresores , Pterigion , Humanos , Pterigion/cirugía , Pterigion/diagnóstico , Ciclosporina/administración & dosificación , Masculino , Femenino , Persona de Mediana Edad , Adhesivo de Tejido de Fibrina/administración & dosificación , Inmunosupresores/administración & dosificación , Estudios Retrospectivos , Estudios de Seguimiento , Adulto , Adhesivos Tisulares/administración & dosificación , Adhesivos Tisulares/uso terapéutico , Resultado del Tratamiento , Anciano , Soluciones Oftálmicas/administración & dosificación , Procedimientos Quirúrgicos Oftalmológicos/métodos , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos , Recurrencia , Conjuntiva , Lágrimas/metabolismo , Lágrimas/fisiología
8.
Cornea ; 43(9): 1072-1079, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38830192

RESUMEN

PURPOSE: Recent advancements in infrared sensing technology have made it possible to visualize tear film dynamics in real time, enabling evaluation of tear film quality during blinking. A retrospective clinical evaluation was conducted to explore this by grading videos of the tear film and comparing grading data with dry eye diagnostic results using the OCULUS keratograph (K5M). METHODS: Videos were used to grade patients' tear film perturbations as compared with healthy control subjects. The grading was then correlated with the ocular surface disease index (OSDI) scores, tear film breakup time (TFBUT), tear meniscus height (TMH), corneal staining, redness, and meibography data. RESULTS: Infrared imaging of the ocular surface revealed instantaneous and recurring dynamic characteristics of the tear film, allowing for the differentiation between normal and abnormal tear films. Abnormal features included a complete absence of a spreading tear film, hindered spreading of the tear film after blinking, areas of tear film instability, or a combination of the latter 2. Some of these features show a resemblance to the tear film appearance after fluorescein staining. The grading of these features correlated with TFBUT and, to a lesser extent, with TMH but did not show significant correlation with any other diagnostic data from the K5M. Furthermore, the speed of tear film spreading after blinking showed a positive correlation with TMH. CONCLUSIONS: Direct visualization of the tear film across the entire palpebral aperture using infrared sensing offers a noninvasive, reproducible, and rapid method for assessing the health and quality of the tear film.


Asunto(s)
Parpadeo , Síndromes de Ojo Seco , Lágrimas , Humanos , Lágrimas/fisiología , Lágrimas/química , Lágrimas/metabolismo , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/fisiopatología , Estudios Retrospectivos , Parpadeo/fisiología , Femenino , Masculino , Adulto , Persona de Mediana Edad , Técnicas de Diagnóstico Oftalmológico , Rayos Infrarrojos , Córnea/diagnóstico por imagen , Anciano
9.
Int Ophthalmol ; 44(1): 277, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38916702

RESUMEN

PURPOSE: Exploring the prevalence of dry eye (DE) and the changes of tear film stability in patients with primary acquired obstruction of the nasolacrimal duct (PANDO). METHODS: In this cross-sectional, observational study, 370 eyes in 223 patients with PANDO were assessed. The ocular surface disease index (OSDI) was used to evaluate ocular surface symptoms, and the Keratograph 5M non-invasive ocular surface analyser was used to assess ocular surface parameters. According to the TFOS DEWS II criteria, patients with OSDI ≥ 13 and NIKBUT < 10 s were diagnosed with DE. RESULTS: Of the 223 PANDO patients, 65 (29.1%) met the diagnostic criteria for DE. Compared with patients without DE, PANDO patients with DE were significantly older (p < 0.001), had a longer duration of epiphora (p = 0.023), and more likely to have a positive regurgitation on pressure over the lacrimal sac (ROPLAS) sign (p = 0.003). Multifactorial analysis showed that older age, positive ROPLAS and hypertension were significant independent predictors of DE (p < 0.05). Among the 147 unilateral PANDO patients without DE, the TMH, NIKBUT-first, NIKBUT-average and bulbar erythema scores were significantly higher in the PANDO sides. CONCLUSIONS: This study illustrated the prevalence of DE in PANDO patients was 29.1% and DE is more likely to occur in those who are older, have hypertension and are positive for ROPLAS. In addition, in patients with unilateral nasolacrimal duct obstruction, a decrease in tear film stability was observed in the healthy eye.


Asunto(s)
Síndromes de Ojo Seco , Obstrucción del Conducto Lagrimal , Conducto Nasolagrimal , Lágrimas , Humanos , Obstrucción del Conducto Lagrimal/diagnóstico , Femenino , Masculino , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/epidemiología , Síndromes de Ojo Seco/metabolismo , Estudios Transversales , Lágrimas/metabolismo , Lágrimas/fisiología , Persona de Mediana Edad , Anciano , Prevalencia , Adulto , Anciano de 80 o más Años
10.
Niger J Clin Pract ; 27(5): 628-634, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38842712

RESUMEN

BACKGROUND: The hormonal and metabolic changes that occur during uncomplicated pregnancy affect the eye. The effects of maternal age and parity on the physiological eye changes in pregnancy have been scarcely documented. AIM: To determine these effects on some physiological eye changes that occur in pregnancy. METHODS: A longitudinal study involving consecutively recruited 140 pregnant women aged 18-48 years attending antenatal clinic at the University of Nigeria Teaching Hospital, Enugu. A structured questionnaire was administered to consenting women, after which the Schirmer test, tear break-up time (tBUT), corneal sensitivity, central corneal thickness (CCT), and intraocular pressure (IOP) was measured in the second and third trimesters, and six weeks after delivery. RESULTS: The mean CCT showed a significantly greater increase among the multiparous (≥para 2) women in both the second and third trimesters compared with the primigravida/primiparous women (P = 0.032 and 0.049, respectively). There was no difference in mean CCT between the two parity groups at six weeks postpartum. Women aged 18-35 years showed a significantly greater increase in the mean CCT in the second trimester compared to those aged less than 35 years (P = 0.04). However, there was no difference in the mean CCT between the different age groups in the third trimester and at six weeks postpartum. CONCLUSION: The age and parity of women affect their level of CCT changes in pregnancy. Consideration of this effect may guide clinicians on their approaches to eye care and treatment during pregnancy.


Asunto(s)
Paridad , Humanos , Femenino , Embarazo , Adulto , Paridad/fisiología , Estudios Prospectivos , Adulto Joven , Estudios Longitudinales , Adolescente , Nigeria , Persona de Mediana Edad , Presión Intraocular/fisiología , Córnea/fisiología , Factores de Edad , Edad Materna , Lágrimas/fisiología , Lágrimas/metabolismo
11.
Optom Vis Sci ; 101(5): 272-275, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38857039

RESUMEN

SIGNIFICANCE: Loss of homeostasis and chronic inflammation result in ocular surface damage in dry eyes, which is also associated with corneal thinning in established cases. Yet, the correlation between corneal thickness and new cases of dry eyes remains inadequately supported by evidence. PURPOSE: This study aimed to compare the central corneal thickness of new cases of dry eyes to that of age- and gender-matched controls. METHODS: A total of 45 dry eye patients were compared with 61 age- and gender-matched non-dry eye individuals. The Ocular Surface Disease Index (OSDI) questionnaire was used to evaluate symptoms, and the central corneal thickness was measured with a Nidek CEM-530 specular microscope. Patients were grouped based on disease severity (OSDI scores), and the clinical findings were compared between groups for slit-lamp examinations, Schirmer's I test, and tear film breakup time. RESULTS: The median age of patients was 25.0 (interquartile range [IQR], 20.0 to 32.0) and 27.0 (IQR, 20.0 to 32.0) years in the control and dry eye groups, respectively (p=0.63). The median (IQR) values of the OSDI scores, tear film breakup time scores, and Schirmer's test measurements in the control groups were 10.4 (8.3 to 10.4), 12.0 (11.0 to 14.0) seconds, and 16.0 (13.5 to 19.5) mm, respectively, which differed from the dry eye groups (p<0.0001). These values in the dry eye group were 29.1 (25.0 to 39.5), 4.0 (3.0 to 8.0) seconds, and 8.0 (3.5 to 11.0) mm, respectively. Patients with dry eyes had lower central corneal thickness than controls (p<0.01). The mean ± standard deviation central corneal thicknesses in patients with dry eyes and the control group were 520.3 ± 26.8 and 545.3 ± 18.8 µm, respectively. CONCLUSIONS: The central corneal thickness in dry eyes was significantly reduced compared with the control group. These findings may be useful in monitoring and managing dry eyes and should be considered in intraocular pressure measurements and refractive surgical procedures.


Asunto(s)
Córnea , Síndromes de Ojo Seco , Humanos , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Femenino , Masculino , Córnea/patología , Córnea/diagnóstico por imagen , Estudios de Casos y Controles , Adulto , Adulto Joven , Lágrimas/fisiología , Lágrimas/metabolismo , Encuestas y Cuestionarios , Paquimetría Corneal , Persona de Mediana Edad
12.
Jpn J Ophthalmol ; 68(4): 338-345, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38795194

RESUMEN

PURPOSE: To investigate changes in the ocular surface and subjective symptoms during a three months administration of 3% diquafosol long-acting (DQL) eye drops. STUDY DESIGN: Prospective observational study. METHODS: DQL eye drops were administered as the sole treatment for all patients, including those in the group where DQL eye drops were newly prescribed (New DQL) and the group who switched from 3% diquafosol (DQS) eye drops (Switched DQL) in this prospective study. Each group underwent assessment of tear meniscus height (TMH), ocular surface disease index (OSDI), fluorescein break-up time (FBUT), fluorescein score, and Schirmer 1 test before DQL administration, at one month, and at three months. Changes in ocular surface scores and subjective symptoms at each time point were analyzed. RESULTS: The study included a total of 63 eyes of 63 patients, with a mean age of 60.3 ±14.6 (SD). Among them, 29 patients (20 women) were in the New DQL group, and 34 patients (24 women) were in the Switched DQL group. Both the New DQL and Switched DQL groups showed significant improvements in TMH, OSDI, FBUT, Fluorescein Score, and Schirmer 1 test after three months of DQL eye drop administration. CONCLUSION: DQL eye drops have the potential to improve ocular scores and subjective symptoms in patients with DE over a three months period, regardless of whether it is newly initiated or as a switch from DQS eye drops.


Asunto(s)
Síndromes de Ojo Seco , Soluciones Oftálmicas , Polifosfatos , Lágrimas , Nucleótidos de Uracilo , Humanos , Femenino , Estudios Prospectivos , Nucleótidos de Uracilo/administración & dosificación , Soluciones Oftálmicas/administración & dosificación , Polifosfatos/administración & dosificación , Masculino , Síndromes de Ojo Seco/tratamiento farmacológico , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Persona de Mediana Edad , Lágrimas/metabolismo , Lágrimas/fisiología , Resultado del Tratamiento , Estudios de Seguimiento , Factores de Tiempo , Adulto , Anciano , Agonistas del Receptor Purinérgico P2Y/administración & dosificación , Preparaciones de Acción Retardada
13.
Curr Eye Res ; 49(10): 1030-1041, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38813818

RESUMEN

PURPOSE: To assess the safety and efficacy of the dry eye intelligent therapeutic device in rabbits with meibomian gland dysfunction. METHODS: The meibomian gland dysfunction-afflicted rabbits were subjected to treatment using the dry eye intelligent therapeutic device. Various parameters, including eyelid margin, meibomian gland opening, redness, meibomian gland area, keratoconjunctival fluorescence staining, and intraocular pressure, were examined and analyzed using an ocular surface comprehensive examination instrument, slit lamp, and tonometer at corresponding times points. Hematoxylin and eosin staining was performed to examine the mucosal epithelium and meibomian gland. RESULTS: In this study, eyelid margin congestion and meibomian gland opening obstruction were significantly improved after 3 weeks and 4 weeks of treatment, respectively (p < .01, p < .05). The treatment group showed a significant increase in tear meniscus height after 2 weeks, 3 weeks and 4 weeks of treatment (p < .001, p < .01, p < .05). No significant changes were noted in meibomian gland area, redness, intraocular pressure, and keratoconjunctival fluorescence staining of rabbits before and after treatment. Hematoxylin and eosin staining revealed a complete structure of mucosal epithelium and meibomian gland in the treatment group and that the expansion of the blocked meibomian gland duct was reduced. CONCLUSION: The utilization of the dry eye intelligent therapeutic device in treating meibomian gland dysfunction-afflicted rabbits exhibits potential promising safety, efficacy, and overall benefits, thereby offering a novel alternative for managing meibomian gland dysfunction patients in clinical settings.


Asunto(s)
Modelos Animales de Enfermedad , Síndromes de Ojo Seco , Disfunción de la Glándula de Meibomio , Glándulas Tarsales , Lágrimas , Animales , Conejos , Disfunción de la Glándula de Meibomio/terapia , Síndromes de Ojo Seco/terapia , Síndromes de Ojo Seco/fisiopatología , Lágrimas/fisiología , Lágrimas/metabolismo , Presión Intraocular/fisiología , Resultado del Tratamiento , Masculino
14.
Ophthalmic Physiol Opt ; 44(5): 876-883, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38712751

RESUMEN

OBJECTIVE: This randomised clinical trial assessed the impact on symptoms, tear film dynamics and ocular surface integrity of daily disposable silicone-hydrogel contact lenses (CLs) over a month, paying special attention to lid wiper epitheliopathy (LWE) and its implications for CL discomfort. METHODS: Neophyte CL wearers (n = 44, 21.09 ± 5.00 years old) were randomly assigned to either the experimental (n = 24) or control group (n = 20). Participants assigned to the experimental group were required to wear daily disposable CLs for 1 month for at least 8 h/day and 6 days/week. All participants were healthy subjects (no history of ocular surgery or active ocular disease) with spherical refractive errors between -8.00 and +5.00 D and cylindrical power <0.75 D. At the baseline and 1-month sessions, the Dry Eye Questionnaire 5 (DEQ-5) was completed, together with the measurement of tear film osmolarity with the TearLab osmometer, tear meniscus height (TMH) and lipid layer pattern (LLP) using a slit-lamp with Tearscope Plus attached, fluorescein break-up time (FBUT), maximum blink interval (MBI), corneal staining with fluorescein under cobalt blue light and LWE with lissamine green under slit lamp and halogen white light. RESULTS: At the baseline session, LWE showed a negative correlation with DEQ-5 (r = -0.37, p = 0.02). Significant differences in FBUT and LWE (p = 0.04) and a positive correlation between LWE and DEQ-5 (r = 0.49, p = 0.007) were observed at 1 month. Intrasession analysis at 1 month showed significant differences between the experimental and control groups in DEQ-5, FBUT and LWE (all p ≤ 0.02). Intersession analysis in the experimental group showed variations in DEQ-5, FBUT and LWE (all p ≤ 0.02) but no significant variation in the control group (all p ≥ 0.11). CONCLUSION: The presence of LWE was significantly correlated with higher symptom values in the DEQ-5. Also, participants in the experimental group presented higher values of LWE after 1 month of CL wear, in comparison with the control group.


Asunto(s)
Lentes de Contacto Hidrofílicos , Equipos Desechables , Síndromes de Ojo Seco , Lágrimas , Humanos , Masculino , Femenino , Lágrimas/fisiología , Lágrimas/metabolismo , Adulto Joven , Síndromes de Ojo Seco/fisiopatología , Síndromes de Ojo Seco/diagnóstico , Adulto , Errores de Refracción/terapia , Errores de Refracción/fisiopatología , Siliconas , Adolescente , Encuestas y Cuestionarios , Enfermedades de los Párpados/fisiopatología , Enfermedades de los Párpados/terapia , Concentración Osmolar
15.
Curr Eye Res ; 49(7): 691-697, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38717137

RESUMEN

PURPOSE: The study aimed to investigate the factors associated with anterior location of Marx's line in ocular surface and living habits, especially in tear film. MATERIALS AND METHODS: This cross-sectional study enlisted 483 participants with meibomian gland dysfunction, who were divided into two groups: 160 participants with mild anterior location of Marx's line and 323 participants with moderate-to-severe anterior location. Participants completed a survey of demographic characteristics (sex, age, length of visual terminal use, sleep duration, skin property), and the Ocular Surface Disease Index and Standard Patient Evaluation of Eye Dryness questionnaires. They also underwent slit-lamp examinations of the lids, and measurements of non-invasive tear break up time, tear meniscus height, fluorescein tear break up time, lipid layer thickness, partial blink rate, lid wiper epitheliopathy, and meibomian gland dropout. RESULTS: The tear meniscus height (mild:0.21(0.18-0.25), moderate-to-severe:0.19(0.16-0.23), p = 0.004), fluorescein tear break up time(mild:3(2-4),moderate to severe:2(1-3), p = 0.000), max LLT(mild:87(62-100), moderate-to-severe:99(69-100), p = 0.04), average LLT(mild:64.5(47.5-96.75), moderate-to-severe:74(53-100), p = 0.012), min LLT(mild:52(38-75), moderate-to-severe:59(41-85), p = 0.029) differed significantly between mild and moderate-to-severe anterior location of Marx's line, and associated to the anterior location of Marx's line(r=-0.134, p = 0.03; r=-0.194, p = 0.000; r = 0.093, p = 0.041; r = 0.119, p = 0.009; r = 0.105, p = 0.022) However, no statistical significance was observed in the OSDI, SPEED, partial blink rate, non-invasive tear breakup time, lipid layer thickness, meibomian gland dropout and lid wiper epitheliopathy(p > 0.05). Meanwhile, in the demographic characteristics, statistically significant correlations were associated with skin property(r = 0.154, p = 0.001) and sleep duration(r=-0.124, p = 0.006), but not with age, sex, and the length of visual terminal use (p > 0.05). CONCLUSIONS: Lower TMH and shorter TBUT positively correlated with anterior location of the Marx's line, and were risk factors. Meanwhile, participants with oily skin and shorter sleep duration were more likely to exhibit anterior location of Marx's line.


Asunto(s)
Disfunción de la Glándula de Meibomio , Glándulas Tarsales , Lágrimas , Humanos , Estudios Transversales , Masculino , Femenino , Lágrimas/metabolismo , Lágrimas/fisiología , Persona de Mediana Edad , Glándulas Tarsales/diagnóstico por imagen , Glándulas Tarsales/metabolismo , Glándulas Tarsales/patología , Adulto , Disfunción de la Glándula de Meibomio/diagnóstico , Disfunción de la Glándula de Meibomio/metabolismo , Disfunción de la Glándula de Meibomio/fisiopatología , Encuestas y Cuestionarios , Parpadeo/fisiología , Síndromes de Ojo Seco/diagnóstico , Síndromes de Ojo Seco/metabolismo , Síndromes de Ojo Seco/fisiopatología , Anciano , Factores de Riesgo
16.
Ophthalmic Plast Reconstr Surg ; 40(3): 352-355, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38722779

RESUMEN

PURPOSE: Congenital distichiasis is managed either by ablation, using laser, cryotherapy, or electroepilation, or by surgical excision with mucous membrane grafting. Ablative procedures are usually blind as the exact depth of distichiatic eyelashes is unknown. The described surgical technique utilizes meibography for imaging the root and depth of distichiatic eyelashes that aided in performing electroepilation. METHODS: Six patients (n = 24 eyelids; mean age 15.5 ± 12.2 years) underwent infrared meibography (Oculus Keratograph 5 M) and noninvasive tear breakup time prospectively. Eyelashes were electroepilated using a premarked needle inserted at a depth based on meibography findings in 4 patients. Surgical success was defined as no distichiatic eyelash regrowth and functional success was defined as the resolution of symptoms at a minimum of 3 months of follow-up. RESULTS: All 6 patients had all 4 eyelids involved to varying degrees, with a total of 230 distichiatic eyelashes. The median number of distichiatic eyelashes was 9 in the upper eyelids and 4.5 in the lower eyelids. Meibography revealed visible distichiatic eyelash roots in 70% of eyelashes in the upper eyelid and 87.8% in the lower eyelid, respectively. The median eyelash root depth was 2.7 mm (mean 2.9 mm, range 1.8-5.4 mm). The mean noninvasive tear breakup time was 12.2 seconds despite absent or rudimentary meibomian gland segments seen on meibography. The anatomical success was 75% (12/16 eyelids), and functional success was 87.5% (7/8 eyes) at a median follow-up of 5.5 months. CONCLUSION: Preoperative infrared meibography in eyelids with congenital distichiasis helps estimate the eyelash depth and can be used to guide eyelash ablation procedures.


Asunto(s)
Pestañas , Glándulas Tarsales , Humanos , Femenino , Masculino , Pestañas/anomalías , Adolescente , Adulto , Niño , Glándulas Tarsales/diagnóstico por imagen , Adulto Joven , Estudios Prospectivos , Lágrimas/metabolismo , Lágrimas/fisiología , Electrocirugia/métodos , Enfermedades de los Párpados/cirugía , Enfermedades de los Párpados/diagnóstico , Enfermedades de los Párpados/congénito
18.
Eye Contact Lens ; 50(8): 342-347, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38780404

RESUMEN

PURPOSE: To compare the effects of 2% rebamipide clear solution and 0.1% sodium hyaluronate eye drops in patients with visual display terminal (VDT)-related dry eye disease (DED). DESIGN: Prospective, randomized, double-blinded Study. METHODS: This was a prospective, double-blind, and randomized controlled study. Patients with VDT-related DED were randomly allocated to a 2% rebamipide (REB) group or a 0.1% sodium hyaluronate (HYA) group (4 times/day for 4 weeks). The ocular surface disease index (OSDI), dry eye questionnaire-5 (DEQ-5), Placido disk-tear film analyzer, fluorescein-stained tear break-up time (FBUT), ocular surface staining score, and Schirmer 1 test were examined before and after the instillation of drug. RESULTS: A total of 56 eyes of 28 patients (28 eyes of 14 patients in each group) were included. There were no significant differences in the baseline data. The OSDI, DEQ-5, FBUT, and conjunctival erosion scores improved significantly in both groups after treatment. In the REB group, corneal staining and bulbar nasal redness scores also improved significantly after treatment ( P <0.001 and 0.036, respectively), whereas no significant differences were found in these parameters in the HYA group ( P =0.326 and 0.118, respectively). The REB group showed a significantly larger decrease in the corneal staining score than the HYA group ( P =0.016). No adverse reactions were observed. CONCLUSIONS: A 2% rebamipide clear solution effectively improved the symptoms and signs in patients with VDT-related DED and was superior to 0.1% sodium hyaluronate ophthalmic solution in improving corneal epithelial damage, making it a safe and effective treatment option for VDT-related DED.


Asunto(s)
Alanina , Terminales de Computador , Síndromes de Ojo Seco , Soluciones Oftálmicas , Quinolonas , Lágrimas , Humanos , Síndromes de Ojo Seco/tratamiento farmacológico , Método Doble Ciego , Estudios Prospectivos , Masculino , Femenino , Quinolonas/administración & dosificación , Quinolonas/uso terapéutico , Persona de Mediana Edad , Alanina/análogos & derivados , Alanina/uso terapéutico , Alanina/administración & dosificación , Adulto , Lágrimas/metabolismo , Lágrimas/fisiología , Ácido Hialurónico/administración & dosificación , Ácido Hialurónico/análogos & derivados , Anciano , Resultado del Tratamiento
19.
Ophthalmic Physiol Opt ; 44(5): 894-909, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38708449

RESUMEN

PURPOSE: To investigate whether there is a measurable change in meibomian gland morphological characteristics over the course of a day (12 h) and over a month. METHODS: The study enrolled 15 participants who attended a total of 11 study visits spanning a 5-week period. To assess diurnal changes in meibomian glands, seven visits were conducted on a single day, each 2 h apart. For monthly assessment, participants attended an additional visit at the same time of the day every week for three consecutive weeks. Meibography using the LipiView® II system was performed at each visit, and meibomian gland morphological parameters were calculated using custom semi-automated software. Specifically, six central glands were analysed for gland length ratio, gland width, gland area, gland intensity and gland tortuosity. RESULTS: The average meibomian gland morphological metrics did not exhibit significant changes during the course of a day or over a month. Nonetheless, certain individual gland metrics demonstrated notable variation over time, both diurnally and monthly. Specifically, meibomian gland length ratio, area, width and tortuosity exhibited significant changes both diurnally and monthly when assessed on a gland-by-gland basis. CONCLUSIONS: Meibomian glands demonstrated measurable structural change over short periods of time (hours and days). These results have implications for innovation in gland imaging and for developing precision monitoring of gland structure to assess meibomian gland health more accurately.


Asunto(s)
Glándulas Tarsales , Humanos , Glándulas Tarsales/diagnóstico por imagen , Glándulas Tarsales/anatomía & histología , Proyectos Piloto , Femenino , Masculino , Persona de Mediana Edad , Adulto , Anciano , Disfunción de la Glándula de Meibomio/diagnóstico , Disfunción de la Glándula de Meibomio/diagnóstico por imagen , Lágrimas/fisiología , Ritmo Circadiano/fisiología , Factores de Tiempo
20.
Open Vet J ; 14(3): 846-851, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38682139

RESUMEN

Background: Healthy vision in humans and animals requires a stable tear film. The environmental factor could affect the status of the tear film. Therefore, assessing the tear film in animals is essential to avoid visual system disturbance. Aim: The current research used a noninvasive device to evaluate the tear meniscus height (TMH) and lipid layer pattern (LLP) in domestic cats. In addition, the scores were compared with those of humans with healthy eyes. Methods: Fifty-four domestic cats (28 males and 26 females; mean ± SD = 13.9 ± 18.2 months) were randomly selected and included in the study. The cats were healthy, without any ocular disorders or diseases. Fifty-four healthy eye subjects (27 males and 27 females; mean ± SD = 25.6 ± 5.1 years) were randomly recruited and took part in the study for comparison. EASYTEAR View+ was used, for the first time, to assess the tear film parameters on the right eye of each subject. The examiner allowed a 5-minute gap between the tests. Each test was performed by the same examiner three times, followed by calculating the mean scores. Results: Significant differences (Mann-Whitney U test) were found in the median scores of LLP (p = 0.009) between cats and subjects with healthy eyes. The median TMH score was higher in cats (0.18 mm) than in humans (0.14). However, no significant difference (Mann-Whitney U Test, p = 0.210) exists in the TMH scores between cats and humans. The LLP analysis indicated that a dense white-blue lipid layer (grade 4 or D; lipid layer thickness, LLT, = approximately 80 nm) was predominant in both cats (N = 24, 44.4%) and humans (N = 29, 53.7%). In comparison, variable colors lipid layer (grade 5 or E; LLT = 90-140 nm) was a minority in cats (N = 5, 9.3%) and common in humans (N = 16, 29.6%). The statistical analysis indicated medium correlations between cats' TMH and LLP scores (r = 0.431, p < 0.01) and between age and TMH scores in humans (r = 0.440, p < 0.01). In addition, it indicated a weak correlation (r = 0.291, p < 0.05) between the LLP scores in cats and humans. Conclusion: Assessing animals' tear film is essential to avoid any ocular disorders. EASYTEAR View+ is efficiently used to evaluate domestic cats' TMH and LLP. Cats have thicker lipid layers and longer TMH comparable to those reported for humans with healthy eyes.


Asunto(s)
Lágrimas , Animales , Gatos/fisiología , Lágrimas/fisiología , Masculino , Femenino , Lípidos/análisis , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...