Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 9.149
Filtrar
1.
Harefuah ; 163(5): 278-285, 2024 May.
Artículo en Hebreo | MEDLINE | ID: mdl-38734939

RESUMEN

INTRODUCTION: The importance of myopia management lies in the desire to minimize the potential ocular risks that increase with high myopia. AIMS: To assess the decrease in myopia progression using topical low dose atropine combined with peripheral blur contact lenses (CL). METHODS: This retrospective review study included 25 children between the ages of 8.5 years to 14 years. The children all had a minimal increase in myopia of 0.75D during the year prior to treatment. The children were divided into two groups. The control group included 14 children who wore single-vision spectacles )SV) averaging 3.20±0.9D ranging from 1.5-5.3D. The study group included 11 children who wore dual-focus CL, with an average prescription of 3.4±0.7D ranging from 2.5 to 4.3D, for one year. At that point, when an additional myopia increase was observed, the children were additionally treated with topical 0.01% atropine for two years (CL+A0.01). RESULTS: There was an increase in myopia in the SV group of 1.12±0.52D, 1.08±0.56D and 0.96±0.53D in the first, second, and third years, respectively. The myopia increase in the CL+A0.01 group was 0.57±0.48D, 0.14±0.34D, and 0.17±0.29D in the first, second, and third years, respectively. CONCLUSIONS: Low-dose atropine combined with peripheral blur contact lenses was effective in decreasing myopia progression in this study. Additional, larger-scale studies are required in the future. DISCUSSION: This study found a significant decrease in myopia progression in the second and third years of treatment. The CL group showed less effectivity than the CL+A0.01 group.


Asunto(s)
Atropina , Lentes de Contacto , Progresión de la Enfermedad , Miopía , Humanos , Atropina/administración & dosificación , Niño , Miopía/terapia , Miopía/fisiopatología , Estudios Retrospectivos , Adolescente , Masculino , Femenino , Resultado del Tratamiento , Midriáticos/administración & dosificación , Soluciones Oftálmicas/administración & dosificación , Anteojos
2.
Vestn Oftalmol ; 140(2): 72-77, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38742501

RESUMEN

The modern treatment strategy for keratoconus (KC) involves sequential application of medical technologies aimed at stabilizing pathological changes in the cornea and restoring visual acuity. PURPOSE: This study compares the effect of implantation of intrastromal corneal ring segment (ICRS) and fitting of individual scleral rigid contact lenses (RCLs) on visual functions in patients with stage II-III KC after previously performed corneal collagen cross-linking. MATERIAL AND METHODS: The Helmholtz National Medical Research Center of Eye Diseases examined and treated 34 patients (69 eyes) aged 18 to 33 years with stage II-III KC. The study included patients who had previously undergone standard corneal collagen cross-linking. Depending on the type of optical correction, the patients were divided into two groups: patients in group 1 underwent ICRS implantation using a femtosecond laser; patients in group 2 were fitted with individual scleral RCLs. RESULTS: Improvement in clinical and functional parameters was observed in both groups. A higher clinical and functional result was achieved in group 2. CONCLUSION: For patients with stable stage II-III KC, it is advisable to recommend fitting of individual scleral RCLs for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Queratocono , Esclerótica , Agudeza Visual , Humanos , Queratocono/cirugía , Queratocono/diagnóstico , Queratocono/fisiopatología , Queratocono/terapia , Femenino , Masculino , Adulto , Esclerótica/cirugía , Implantación de Prótesis/métodos , Implantación de Prótesis/instrumentación , Resultado del Tratamiento , Topografía de la Córnea , Prótesis e Implantes , Adulto Joven , Ajuste de Prótesis/métodos , Adolescente , Sustancia Propia/cirugía
3.
Invest Ophthalmol Vis Sci ; 65(5): 4, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691089

RESUMEN

Purpose: To investigate the adhesion of Acanthamoeba to scleral contact lens (ScCL) surface according to lens shape. Methods: Two strains of A. polyphaga (CDC:V062 and ATCC 30461) and one clinical Acanthamoeba isolate, were inoculated onto five contact lens (CL): one first-generation silicone hydrogel (SHCL; lotrafilcon B; adhesion control) containing plasma surface treatment; two ScCL (fluorosilicone acrylate) one containing surface treatment composed of plasma and the other containing plasma with Hydra-PEG, and two CL designed with a flat shape having the same material and surface treatments of the ScCL. Trophozoites that adhered to the lens's surfaces were counted by inverted optical light microscopy. Possible alterations of the lens surface that could predispose amoeba adhesion and Acanthamoeba attached to these lens surfaces were evaluated by scanning electron microscopy (SEM). Results: All strains revealed greater adhesion to the ScCL when compared with the flat lenses (P < 0.001). The clinical isolate and the ATCC 30461 had a higher adhesion (P < 0.001) when compared with the CDC:V062. A rough texture was observed on the surface of the lenses that have been examined by SEM. Also, SEM revealed that the isolates had a rounded appearance on the surface of the ScCL in contrast with an elongated appearance on the surface of the silicone hydrogel. Conclusions: The findings revealed that the curved shape of the ScCL favors amoeba adhesion.


Asunto(s)
Acanthamoeba , Microscopía Electrónica de Rastreo , Acanthamoeba/fisiología , Acanthamoeba/ultraestructura , Esclerótica , Humanos , Lentes de Contacto Hidrofílicos/parasitología , Adhesión Celular/fisiología , Lentes de Contacto/parasitología , Trofozoítos/ultraestructura , Trofozoítos/fisiología , Hidrogeles , Animales
5.
Transl Vis Sci Technol ; 13(5): 12, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758570

RESUMEN

Purpose: To evaluate the visual performance in adolescents undergoing orthokeratology (OrthoK) treatment with two different optical zone diameters (OZDs). Methods: This randomized, double-masked, self-controlled prospective study was conducted at Tianjin Eye Hospital (Tianjin, China) in June 2022. Thirty-six eligible schoolchildren were enrolled and fitted with corneal refractive therapy lenses with two sizes of OZDs (5 mm [5OZ] and 6 mm [6OZ]). Each participant was randomized to wear the 5OZ in one eye and the 6OZ in the contralateral eye. Subjective visual quality was assessed using visual acuity, refraction, contrast sensitivity function, and visual symptoms, and the objective optical quality was assessed using ocular higher order aberrations (HOAs) and modulation transfer function (MTF). Results: Thirty-five myopic children completed a 1-month follow-up visit. The 5OZ lens induced significantly smaller treatment zone diameters than the 6OZ lens (P < 0.001). Subjective visual quality did not differ significantly between the two groups. Compared to baseline, aberrations of Z40, coma-like, spherical-like, and total HOAs in both groups increased significantly (P < 0.05). For the 3-mm pupils, spherical aberration in the 5OZ group was significantly higher than that in the 6OZ group (P < 0.05). The MTF value of the 6OZ group was significantly higher than that of 5OZ group for 0.3 and 1.5 cycles per degree for the 3-mm pupils (P = 0.006 and P = 0.026, respectively). However, HOAs or MTF did not differ significantly between the two groups for the 5-mm pupils. Conclusions: The difference induced by varying OZD was significant only in the smaller pupil condition. The selection of OZD in OrthoK designs in real-world patient management should be done while considering individual pupil size. Translational Relevance: This study revealed that the objective visual quality of small OZD lenses was only slightly affected for the small pupil size.


Asunto(s)
Miopía , Procedimientos de Ortoqueratología , Refracción Ocular , Agudeza Visual , Humanos , Femenino , Procedimientos de Ortoqueratología/métodos , Masculino , Agudeza Visual/fisiología , Estudios Prospectivos , Adolescente , Miopía/terapia , Miopía/fisiopatología , Niño , Método Doble Ciego , Refracción Ocular/fisiología , Sensibilidad de Contraste , Lentes de Contacto
6.
Sci Adv ; 10(15): eadl3262, 2024 Apr 12.
Artículo en Inglés | MEDLINE | ID: mdl-38598619

RESUMEN

Contact lenses (CLs) are prone to adhesion and invasion by pollutants and pathogenic bacteria, leading to infection and inflammatory diseases. However, the functionalization of CL (biological functions such as anti-fouling, antibacterial, and anti-inflammatory) and maintaining its transparency still face great challenges. In this work, as a member of the MXenes family, vanadium carbide (V2C) is modified onto CL via a water transfer printing method after the formation of a tightly arranged uniform film at the water surface under the action of the Marangoni effect. The coating interface is stable owing to the electrostatic forces. The V2C-modified CL (V2C@CL) maintains optical clarity while providing good biocompatibility, strong antioxidant properties, and anti-inflammatory activities. In vitro antibacterial experiments indicate that V2C@CL shows excellent performance in bacterial anti-adhesion, sterilization, and anti-biofilm formation. Last, V2C@CL displays notable advantages of bacteria elimination and inflammation removal in infectious keratitis treatment.


Asunto(s)
Infecciones Bacterianas , Lentes de Contacto , Humanos , Antibacterianos/farmacología , Antiinflamatorios , Bacterias , Lentes de Contacto/microbiología , Inflamación , Nitritos , Elementos de Transición , Agua , Impresión
7.
Biomacromolecules ; 25(5): 2728-2739, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38563621

RESUMEN

Myopia is a global public health issue. Rigid contact lenses (RCLs) are an effective way to correct or control myopia. However, bioadhesion issues remain one of the significant obstacles limiting its clinical application. Although enhancing hydrophilicity through various surface treatments can mitigate this problem, the duration of effectiveness is short-lived and the processing involved is complex and costly. Herein, an antiadhesive RCLs material was designed via 8-armed methacrylate-POSS (8MA-POSS), and poly(ethylene glycol) methacrylate (PEGMA) copolymerization with 3-[tris(trimethylsiloxy)silyl] propyl methacrylate (TRIS). The POSS and PEG segments incorporated P(TRIS-co-PEGMA-co-8MA-POSS) (PTPM) material was obtained and their optical transparency, refractive index, resolution, hardness, surface charge, thermal features, and wettability were tested and optimized. The antibioadhesion activities, including protein, lipid, and bacteria, were evaluated as well. In vitro and in vivo results indicated that the optimized antibioadhesive PTPM materials present good biocompatibility and biosafety. Thus, such POSS and PEG segments containing material were a potential antibioadhesive RCL material option.


Asunto(s)
Lentes de Contacto , Metacrilatos , Compuestos de Organosilicio , Polietilenglicoles , Polietilenglicoles/química , Metacrilatos/química , Animales , Compuestos de Organosilicio/química , Compuestos de Organosilicio/farmacología , Adhesión Bacteriana/efectos de los fármacos , Ratones , Materiales Biocompatibles/química , Humanos , Miopía/tratamiento farmacológico
8.
Sci Rep ; 14(1): 8878, 2024 04 17.
Artículo en Inglés | MEDLINE | ID: mdl-38632261

RESUMEN

This prospective single-arm study aimed to evaluate the clinical efficacy and safety of a refractive multifocal contact lens for the correction of presbyopia in 22 patients. The participants underwent clinical examinations before and 1 week after wearing a refractive multifocal contact lens (OptaCon ZOOM). The primary endpoints were the corrected distance visual acuity (CDVA) and distance-corrected near visual acuity (DCNVA). Defocus curve, contrast sensitivity, and ocular surface disease index (OSDI) were analyzed. A slit-lamp examination was performed for safety analysis. Contact lens comfort and patient satisfaction were assessed using a questionnaire. No significant difference in CDVA was observed before and 1 week after refractive multifocal contact lens use (p = 0.127), whereas DCNVA was significantly improved after 1 week (p < 0.001). The contrast sensitivity was not significantly affected at any spatial frequency under mesopic or photopic conditions. OSDI was significantly increased (p = 0.023). The patient-reported satisfaction scores were 96.2, 91.9, and 85.0 out of 100 at far, intermediate, and near distances, respectively. No significant adverse events were observed. Refractive multifocal contact lenses improved near vision while maintaining distance vision in presbyopic patients, without compromising contrast sensitivity. The study results suggest that OptaCon ZOOM can be considered safe and effective for the correction of presbyopia.


Asunto(s)
Lentes de Contacto , Presbiopía , Humanos , Estudios Prospectivos , Refracción Ocular , Agudeza Visual
9.
Turk J Ophthalmol ; 54(2): 90-102, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38645732

RESUMEN

Congenital cataract is among the main causes of treatable vision loss in childhood. The first weeks and months of life are a critical time for the development of vision. Therefore, early cataract surgery and effective multifaceted treatment of the resulting aphakia in the early stages of life are of great value for the management of vision development. Among the treatment models, contact lenses (CL) have an important place in infancy and early childhood up to the age of 2 years. Although good visual gains were not considered very likely, especially in unilateral aphakia, important steps have been taken in the treatment of pediatric aphakia thanks to the surgical techniques developed over time and the increasing experience with optical correction systems, especially CLs. This review examines current developments in the types of CL used in pediatric aphakia, their application features, comparison with other optical systems, the features of amblyopia treatment in the presence of CL, and the results obtained with family compliance to CL wear and occlusion therapy in the light of existing studies.


Asunto(s)
Afaquia Poscatarata , Lentes de Contacto , Agudeza Visual , Humanos , Afaquia Poscatarata/terapia , Afaquia Poscatarata/fisiopatología , Agudeza Visual/fisiología , Lactante , Preescolar , Catarata/congénito , Extracción de Catarata/métodos , Ambliopía/terapia , Ambliopía/fisiopatología , Afaquia , Niño , Recién Nacido
10.
Turk J Ophthalmol ; 54(2): 103-107, 2024 Apr 19.
Artículo en Inglés | MEDLINE | ID: mdl-38645833

RESUMEN

Facial burns involving the periorbital region may lead to cicatricial ectropion and lagophthalmos, causing severe exposure keratopathy and eventually blindness if uncorrected. In these patients, it is critical to provide aesthetic and functional surgical correction to protect the ocular surface from chronic desiccation in addition to visual rehabilitation. Conventional methods may not be sufficient to provide visual rehabilitation in complex cases. Scleral lenses can be a multipurpose alternative for these patients. Herein, we present the challenging case of a patient who developed cicatricial lagophthalmos and exposure keratopathy after facial transplantation due to gasoline burns and received a scleral contact lens for visual rehabilitation.


Asunto(s)
Lentes de Contacto , Esclerótica , Humanos , Esclerótica/cirugía , Trasplante de Córnea/métodos , Agudeza Visual , Enfermedad Crónica , Quemaduras Oculares/complicaciones , Quemaduras Oculares/cirugía , Quemaduras Oculares/diagnóstico , Quemaduras Químicas/cirugía , Quemaduras Químicas/complicaciones , Masculino , Enfermedades de los Párpados/cirugía , Enfermedades de los Párpados/etiología , Femenino , Lagoftalmos
11.
Zhonghua Yan Ke Za Zhi ; 60(4): 343-351, 2024 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-38583058

RESUMEN

Objective: The aim of this paper is to compare the refractive correction effects of rigid gas permeable contact lenses (RGPCL) and spectacle correction in children with aphakia after congenital cataract surgery. Methods: This was a prospective non-randomized controlled trial. Children with aphakic eyes after congenital cataract surgery, who underwent vision correction in the Strabismus and Pediatric Ophthalmology Clinic of Beijing Tongren Hospital affiliated with Capital Medical University from April 2012 to November 2019, were continuously collected. Those who voluntarily chose to wear RGPCL for refractive correction were included in the experimental group. Patients with monocular disease were in trial group 1, and patients with binocular disease were in trial group 2. Patients who chose to wear frame glasses for refractive correction were included in the control group. Patients with monocular disease were in control group 1, and patients with binocular disease were in control group 2. Regional origin, medical history, and family information were collected at the first diagnosis. During the follow-up, adverse reactions occurring during the process of wearing glasses were recorded. The Teller acuity card was used for visual examination to obtain the best-corrected visual acuity and convert it into the logarithm of the minimum resolution angle. The degree of nystagmus was determined according to the amplitude and frequency of nystagmus. Treatment cost, treatment compliance, and the reasons for adopting or not adopting RGPCL were analyzed through a questionnaire completed by the parents of children with RGPCL. Results: A total of 203 children (344 eyes) who underwent congenital cataract surgery were included, including 124 males (210 eyes) and 79 females (134 eyes). The age range was 3 to 36 months. There were 28 cases in the experimental group, including 19 cases in trial group 1 and 9 cases in trial group 2. There were 175 cases in the control group, including 43 cases in control group 1 and 132 cases in control group 2. Except for 6 months of age, the visual acuity of the experimental group was better than that of the control group, and the differences were statistically significant (P<0.05). The visual acuity of children in trial group 1 was better than that of children in control group 1 at the same age. Among them, at 12 months of age [1.54 (1.27, 1.97), 1.84 (0.97, 2.12)], 18 months of age [1.27 (0.97, 1.84), 1.84 (0.97, 2.12)], 24 months of age [1.54 (1.27, 1.84), 1.84 (0.97, 2.12)], and 30 months old [0.97 (0.66, 1.27), 1.54 (0.66, 2.12)], the difference was statistically significant (P<0.001). The visual acuity of children in trial group 2 was better than that in control group 2 at the same age. Among them, at 18 months old [1.27 (0.97, 1.54), 1.27 (0.66, 2.12)], 24 months old [0.97 (0.66, 1.27), 1.27 (0.66, 2.12)], and 30 months old [1.27 (0.66, 2.12)], the difference was statistically significant (P<0.05). The remission rate of nystagmus in the experimental group was 8/9 (8 cases), the remission rate of nystagmus in the control group was 34.40% (32 cases), and the exacerbation rate was 29.03% (27 cases). The average annual cost of the experimental group was 25 125 yuan, and that of the control group was 2 511 yuan. Conclusions: RGPCL is a well-tolerated, safe, and effective treatment for infants and young children. The visual acuity and degree of nystagmus were significantly improved in children who wore RGPCL for aphakia refractive correction after congenital cataract surgery compared with spectacle correction.


Asunto(s)
Afaquia , Extracción de Catarata , Catarata , Lentes de Contacto , Nistagmo Patológico , Oftalmología , Preescolar , Femenino , Humanos , Lactante , Masculino , Catarata/terapia , Catarata/congénito , Anteojos , Estudios Prospectivos
12.
Zhonghua Yan Ke Za Zhi ; 60(4): 330-336, 2024 Apr 11.
Artículo en Chino | MEDLINE | ID: mdl-38583056

RESUMEN

Objective: To investigate the influence of corneal e-value on the effectiveness of orthokeratology in controlling myopia in children and adolescents. Methods: A retrospective cohort study was conducted, involving the data from 1 563 myopic patients (1 563 eyes) who underwent orthokeratology at the Affiliated Eye Hospital of Shandong University of Traditional Chinese Medicine from June 2015 to August 2021 and adhered to lens wear for at least 2 years. The cohort consisted of 737 males and 826 females with an average age of (10.84±2.13) years. Based on corneal e-value parameters obtained from corneal topography, patients were categorized into a low e-value group (n=425) and a high e-value group (n=1 138). Data on gender, age, parental myopia history, and baseline measures such as spherical equivalent (SE), axial length, and corneal e-value were collected. Differences in axial length change and corneal fluorescein staining rates were compared between the two groups at 1 and 2 years after the start of lens wear. A generalized linear mixed model was established with axial length change as the dependent variable to analyze the correlation between axial length change and baseline corneal e-value. Results: The initial age of the 1 563 myopic patients was (10.84±2.13) years, with a baseline SE of (-3.05±1.30) D. After 1 year of lens wear, the axial length change was (0.20±0.19) mm in the low e-value group and (0.24±0.20) mm in the high e-value group. After 2 years, the changes were (0.38±0.25) mm and (0.43±0.27) mm, respectively, with statistically significant differences (all P<0.05). The incidence of corneal staining after 1 year of lens wear was 9.2% (39/425) in the low e-value group and 14.1% (160/1 138) in the high e-value group. After 2 years, the rates were 15.8% (67/425) and 21.8% (248/1 138), respectively, with statistically significant differences (all P<0.05). After adjusting for parental myopia history, age, SE, and baseline axial length, the baseline corneal e-value was positively correlated with axial length change at 1 and 2 years after lens wear (all P<0.05). Conclusions: Corneal e-value is an independent factor influencing the effectiveness of orthokeratology in controlling myopia. A smaller corneal e-value is associated with slower axial length growth after orthokeratology, indicating better control of myopia in treated eyes.


Asunto(s)
Lentes de Contacto , Miopía , Procedimientos de Ortoqueratología , Masculino , Femenino , Niño , Humanos , Adolescente , Estudios Retrospectivos , Longitud Axial del Ojo , Miopía/terapia , Topografía de la Córnea , Refracción Ocular
13.
In Vivo ; 38(3): 1229-1235, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38688617

RESUMEN

BACKGROUND/AIM: Given the characteristics of Serratia marcescens (S. marcescens), this study aimed at investigating its presence in the hands and contact lens cases of orthokeratology wearers, along with the status of bacterial contamination. PATIENTS AND METHODS: The 39 patients received the questionnaires about the background of orthokeratology and hygiene habits. A total of 39 contact lens cases and 39 hand samples from the patients were collected at Show Chwan Memorial Hospital from June to August in 2020 and sent to National Chung Cheng University for DNA extraction and PCR identification. RESULTS: The results indicated a detection rate of 5.13% for S. marcescens in the contact lens cases and 12.82% in the hand samples. Additionally, 66.67% of contact lens case samples and 30.77% of hand samples found positive for 16s bacterial amplicons. The relationship between hand contamination and the duration of contact lens usage were revealed for both S. marcescens (p=0.021) and 16s bacterial amplicons (p=0.048). CONCLUSION: The results indicated that hand hygiene is more critical than focusing on contact lens hygiene when it comes to preventing S. marcescens infections. Nevertheless, both proper hand and contact lens hygiene practices can reduce the detection of bacterial eye pathogens, especially a common intestinal bacterium.


Asunto(s)
Infecciones por Serratia , Serratia marcescens , Humanos , Serratia marcescens/aislamiento & purificación , Serratia marcescens/genética , Masculino , Femenino , Infecciones por Serratia/microbiología , Infecciones por Serratia/epidemiología , Infecciones por Serratia/diagnóstico , Procedimientos de Ortoqueratología/métodos , Lentes de Contacto/microbiología , Lentes de Contacto/efectos adversos , Niño , Adolescente , Higiene , Higiene de las Manos , Adulto , Mano/microbiología
14.
Medicine (Baltimore) ; 103(14): e37663, 2024 Apr 05.
Artículo en Inglés | MEDLINE | ID: mdl-38579080

RESUMEN

BACKGROUND: To report the nursing experience of a case of corneal contact lens wearer receiving the 2nd keratoplasty due to corneal ulcer and perforation caused by Pythium insidiosum infection. METHODS: A 30-year-old female patient had blurred vision after deep anterior lamellar keratoplasty for a right corneal ulcer. At the 5th week, the right eye appeared the symptoms, such as redness and pain. The anterior segment photography was performed on the eye, and the result showed that the epithelium was missing in the right eye lesion area, and a large number of longitudinal and transversal streaks were visible from the epithelium to the stroma, with fungus filaments to be discharged. Upon macro-genome sequencing of the corneal secretion, a P. insidiosum infection was observed. Then, the patient underwent the keratoplasty, and 3 weeks later, the corneal implant showed a tendency to dissolve, the sutures were partially loosened, and the eye was almost blind. Subsequently, the patient was admitted to our hospital and subject to the 2nd penetrating keratoplasty of the right eye (allograft). After surgery, linezolid and azithromycin injections were given through intravenous drip and local drip of the eye for anti-inflammation, and tacrolimus eye drops for antirejection. RESULTS: Postoperatively, the patient showed signs of recovery with slight corneal edema and visible pupil, leading to discharge with improved vision. The corneal implant was normal 1 week after surgery and the vision of the right eye was hand move/before eye at the 6th month of follow-up. Continuous care and removal of sutures 3 months post-surgery contributed to a successful outcome, with the patient achieving hand motion vision 6 months after the procedure. CONCLUSION: Corneal ulcer caused by P. insidiosum infection not only needs timely and effective keratoplasty intervention, but also requires perfect nursing measures.


Asunto(s)
Trasplante de Córnea , Úlcera de la Córnea , Pitiosis , Adulto , Femenino , Humanos , Lentes de Contacto , Córnea/cirugía , Trasplante de Córnea/métodos , Úlcera de la Córnea/etiología , Úlcera de la Córnea/cirugía , Queratoplastia Penetrante , Pitiosis/cirugía , Pitiosis/complicaciones , Pitiosis/diagnóstico
16.
Nat Commun ; 15(1): 3588, 2024 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-38678013

RESUMEN

Eye tracking techniques enable high-efficient, natural, and effortless human-machine interaction by detecting users' eye movements and decoding their attention and intentions. Here, a miniature, imperceptible, and biocompatible smart contact lens is proposed for in situ eye tracking and wireless eye-machine interaction. Employing the frequency encoding strategy, the chip-free and battery-free lens successes in detecting eye movement and closure. Using a time-sequential eye tracking algorithm, the lens has a great angular accuracy of <0.5°, which is even less than the vision range of central fovea. Multiple eye-machine interaction applications, such as eye-drawing, Gluttonous Snake game, web interaction, pan-tilt-zoom camera control, and robot vehicle control, are demonstrated on the eye movement model and in vivo rabbit. Furthermore, comprehensive biocompatibility tests are implemented, demonstrating low cytotoxicity and low eye irritation. Thus, the contact lens is expected to enrich approaches of eye tracking techniques and promote the development of human-machine interaction technology.


Asunto(s)
Algoritmos , Lentes de Contacto , Movimientos Oculares , Tecnología de Seguimiento Ocular , Movimientos Oculares/fisiología , Animales , Humanos , Conejos , Sistemas Hombre-Máquina
17.
Ophthalmic Physiol Opt ; 44(4): 774-786, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38578134

RESUMEN

PURPOSE: To investigate gaze and behavioural metrics at different viewing distances with multifocal contact lenses (MFCLs), single vision contact lenses (SVCLs) and progressive addition lenses (PALs). METHODS: Fifteen presbyopic contact lens wearers participated over five separate study visits. At each visit, participants were randomly assigned to wear one of five refractive corrections: habitual PAL spectacles, delefilcon A (Alcon Inc.) MFCLs and three separate pairs of delefilcon A single vision lenses worn as distance, intermediate and near corrections. Participants wore a Pupil Core headset to record eye and head movements while performing three visual tasks: reading, visual search and scene observation. Data were investigated using linear regression and post-hoc testing. Parameters of interest included gaze (fixation duration, head movement) and behavioural (reading speed, reading accuracy, visual search time) metrics. RESULTS: Reading speed in SVCLs was significantly faster than in MFCLs and PAL spectacles (F = 16.3, p < 0.0001). Refractive correction worn did not influence visual search times (F = 0.16, p = 0.85). Fixation duration was significantly affected by the type of visual task (F = 60.2, p < 0.001), and an interaction effect was observed between viewing distance and refractive correction (F = 4.3, p = 0.002). There was significantly more horizontal and vertical head movement (F = 3.2, p = 0.01 and F = 3.3, p = 0.01, respectively) during visual search tasks when wearing PAL spectacles compared to SVCLs or MFCLs. CONCLUSION: This work showed that the type of refractive correction affects behavioural metrics such as reading speed and gaze behaviour by affecting horizontal and vertical head movements. The findings of this study suggest that under certain conditions, wearers of MFCLs make fewer head movements compared to PAL spectacles. Gaze behaviour metrics offer a new approach to compare and understand contact lens and spectacle performance, with potential applications including peripheral optical designs for myopia management.


Asunto(s)
Lentes de Contacto , Anteojos , Fijación Ocular , Presbiopía , Lectura , Refracción Ocular , Agudeza Visual , Humanos , Presbiopía/fisiopatología , Presbiopía/terapia , Femenino , Masculino , Persona de Mediana Edad , Agudeza Visual/fisiología , Fijación Ocular/fisiología , Refracción Ocular/fisiología , Adulto , Movimientos de la Cabeza/fisiología , Movimientos Oculares/fisiología
18.
Biosens Bioelectron ; 257: 116284, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38657379

RESUMEN

Smart contact lenses (SCLs) have been considered as novel wearable devices for out-of-hospital and self-monitoring applications. They are capable of non-invasively and continuously monitoring physiological signals in the eyes, including vital biophysical (e.g., intraocular of pressure, temperature, and electrophysiological signal) and biochemical signals (e.g., pH, glucose, protein, nitrite, lactic acid, and ions). Recent progress mainly focuses on the rational design of wearable SCLs for physiological signal monitoring, while also facilitating the treatment of various ocular diseases. It covers contact lens materials, fabrication technologies, and integration methods. We also highlight and discuss a critical comparison of SCLs with electrical, microfluidic, and optical signal outputs in health monitoring. Their advantages and disadvantages could help researchers to make decisions when developing SCLs with desired properties for physiological signal monitoring. These unique capabilities make SCLs promising diagnostic and therapeutic tools. Despite the extensive research in SCLs, new technologies are still in their early stages of development and there are a few challenges to be addressed before these SCLs technologies can be successfully commercialized particularly in the form of rigorous clinical trials.


Asunto(s)
Técnicas Biosensibles , Lentes de Contacto , Dispositivos Electrónicos Vestibles , Humanos , Técnicas Biosensibles/instrumentación , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Diseño de Equipo
19.
Cont Lens Anterior Eye ; 47(3): 102173, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38653594

RESUMEN

PURPOSE: To investigate the short-term effect of scleral lens (SL) on corneal curvature and corneal oedema in Pellucid Marginal Degeneration (PMD) eyes. METHODS: Corneal anterior, posterior curvature and corneal thickness were measured in 14 eyes of 14 PMD participants with Schiempflug imaging at different corneal diameters and meridians at baseline and after 6 h of SL wear. RESULTS: There was a significant flattening (up to 0.26 mm) of the anterior corneal curvature noted in the inferotemporal quadrant (from 210 to 255 degree at 2 mm, 8 mm and 10 mm corneal diameter), inferonasal quadrant (from 285 to 345 degree at 6 mm and 8 mm corneal diameter), and inferiorly at 2 mm and 10 mm corneal diameter (p < 0.05). Similarly, posterior corneal curvature showed statistically significant steepening mostly in inferotemporal quadrants (from 195 to 255 degree from 4 mm to 8 mm corneal diameter) and inferonasally at 2 mm and 4 mm corneal diameter (p < 0.05). A statistically significant increase in the corneal thickness noted in different corneal diameters with corneal oedema ranging from 2.10 % to 4.00 % after 6 h of SL wear. A gradual increase in corneal oedema was noted form centre to periphery. The baseline central fluid reservoir thickness (FRT) was 341.07 ± 139.8 which reduced to 276.71 ± 114.32 µm after 6 h of lens wear. No significant correlation was noted between corneal oedema with different parameters like initial and final FRT, change in anterior and posterior corneal curvature, and lens thickness (p > 0.05). CONCLUSIONS: Short-term SL wear induced a clinically acceptable range of corneal oedema. A clinically significant flattening in anterior curvature and minimal steepening in posterior curvature were noted. Practitioners should be careful while measuring corneal parameters in PMD eyes wearing SL, as these alterations can provide false impression of disease progression.


Asunto(s)
Córnea , Edema Corneal , Topografía de la Córnea , Esclerótica , Humanos , Masculino , Femenino , Esclerótica/patología , Córnea/patología , Adulto , Edema Corneal/etiología , Edema Corneal/fisiopatología , Edema Corneal/diagnóstico , Lentes de Contacto , Distrofias Hereditarias de la Córnea/fisiopatología , Adulto Joven , Persona de Mediana Edad , Agudeza Visual/fisiología
20.
ACS Appl Mater Interfaces ; 16(17): 22522-22531, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651323

RESUMEN

Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.


Asunto(s)
Lentes de Contacto , Presión Intraocular , Temperatura , Tecnología Inalámbrica , Presión Intraocular/fisiología , Tecnología Inalámbrica/instrumentación , Animales , Porcinos , Diseño de Equipo , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA