Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 639
Filtrar
1.
JACC Cardiovasc Interv ; 17(12): 1517-1518, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38842997
2.
Catheter Cardiovasc Interv ; 103(6): 1069-1073, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38584521

RESUMEN

An 86-year-old female with history of surgical aortic valve replacement presented with clinical signs of heart failure. Echocardiography revealed a reduction in left ventricular systolic function and severe bioprosthetic aortic valve dysfunction. This is the first reported case of valve-in-valve transcatheter aortic valve replacement with concomitant undermining iatrogenic coronary obstruction with radiofrequency needle procedure in a surgical bioprosthetic valve.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Bioprótesis , Prótesis Valvulares Cardíacas , Enfermedad Iatrogénica , Diseño de Prótesis , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Anciano de 80 o más Años , Femenino , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Resultado del Tratamiento , Válvula Aórtica/cirugía , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/fisiopatología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/fisiopatología , Ablación por Catéter/efectos adversos , Falla de Prótesis , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Lesiones Cardíacas/etiología , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Agujas , Función Ventricular Izquierda , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/etiología , Oclusión Coronaria/terapia , Oclusión Coronaria/fisiopatología , Angiografía Coronaria
3.
Circ Cardiovasc Interv ; 17(6): e013794, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38629311

RESUMEN

BACKGROUND: The extent of cardiac damage and its association with clinical outcomes in patients undergoing transcatheter edge-to-edge repair (TEER) for degenerative mitral regurgitation remains unclear. This study was aimed to investigate cardiac damage in patients with degenerative mitral regurgitation treated with TEER and its association with outcomes. METHODS: We analyzed patients with degenerative mitral regurgitation treated with TEER in the Optimized Catheter Valvular Intervention-Mitral registry, which is a prospective, multicenter observational data collection in Japan. The study subjects were classified according to the extent of cardiac damage at baseline: no extravalvular cardiac damage (stage 0), mild left ventricular or left atrial damage (stage 1), moderate left ventricular or left atrial damage (stage 2), or right heart damage (stage 3). Two-year mortality after TEER was compared using Kaplan-Meier analysis. RESULTS: Out of 579 study participants, 8 (1.4%) were classified as stage 0, 76 (13.1%) as stage 1, 319 (55.1%) as stage 2, and 176 (30.4%) as stage 3. Two-year survival was 100% in stage 0, 89.5% in stage 1, 78.9% in stage 2, and 75.3% in stage 3 (P=0.013). Compared with stage 0 to 1, stage 2 (hazard ratio, 3.34 [95% CI, 1.03-10.81]; P=0.044) and stage 3 (hazard ratio, 4.51 [95% CI, 1.37-14.85]; P=0.013) were associated with increased risk of 2-year mortality after TEER. Significant reductions in heart failure rehospitalization rate and New York Heart Association functional scale were observed following TEER (both, P<0.001), irrespective of the stage of cardiac damage. CONCLUSIONS: Advanced cardiac damage is associated with an increased risk of mortality in patients undergoing TEER for degenerative mitral regurgitation. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: UMIN000023653.


Asunto(s)
Cateterismo Cardíaco , Implantación de Prótesis de Válvulas Cardíacas , Insuficiencia de la Válvula Mitral , Válvula Mitral , Sistema de Registros , Humanos , Insuficiencia de la Válvula Mitral/cirugía , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/mortalidad , Insuficiencia de la Válvula Mitral/fisiopatología , Masculino , Femenino , Anciano , Válvula Mitral/cirugía , Válvula Mitral/fisiopatología , Válvula Mitral/diagnóstico por imagen , Japón , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/mortalidad , Resultado del Tratamiento , Factores de Tiempo , Estudios Prospectivos , Factores de Riesgo , Anciano de 80 o más Años , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/mortalidad , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Medición de Riesgo , Recuperación de la Función , Lesiones Cardíacas/mortalidad , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Lesiones Cardíacas/diagnóstico por imagen
5.
Catheter Cardiovasc Interv ; 102(6): 1061-1065, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37855161

RESUMEN

Coronary artery perforation (CAP) is a rare but lethal complication of percutaneous coronary interventions (PCIs), and its incidence has been increasing with advances in PCI techniques. Delayed CAP presents a highly challenging complication, as it occurs 30 min-9 days after intervention, making subsequent diagnosis and treatment difficult. We present the case of a 63-year-old male patient who underwent PCI for an obtuse marginalis II because of posterior wall myocardial infarction. Following 4 days of uneventful postoperative stay, the patient developed angina pectoris and hypotension 4 h after reinitiation of anticoagulant therapy with edoxaban. Angiography revealed distal vessel perforation from a side branch of the obtuse marginalis II. The vessel was occluded using autologous fat embolization via a microcatheter, resulting in complete sealing of the perforation. After discharge, 4 weeks after the infarction, the patient started rehabilitation therapy. Distal vessel perforations are typically caused by wire damage. In our case, we also suspected distal wire perforation, which was initially not recognized possibly due to distal occlusion through the thrombotic material. The temporal correlation between the re-initiation of anticoagulant therapy and the occurrence of cardiac tamponade suggests that the thrombotic material was resolved due to the former. The management of delayed CAP does not differ from that of CAP; thus, this rare complication should be considered even days after PCI as it could prove lethal if not recognized early.


Asunto(s)
Taponamiento Cardíaco , Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Masculino , Humanos , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/terapia , Vasos Coronarios/diagnóstico por imagen , Resultado del Tratamiento , Enfermedad de la Arteria Coronaria/complicaciones , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Anticoagulantes , Angiografía Coronaria/efectos adversos
6.
BMC Cardiovasc Disord ; 23(1): 259, 2023 05 19.
Artículo en Inglés | MEDLINE | ID: mdl-37208627

RESUMEN

BACKGROUND: Post cardiac injury syndrome (PCIS) is characterized by the development of pericarditis with or without pericardial effusion due to a recent cardiac injury. The relatively low incidence makes diagnosis of PCIS after implantation of a pacemaker easily be overlooked or underestimated. This report describes one typical case of PCIS. CASE PRESENTATION: We present a case report of a 94-year-old male with a history of sick sinus syndrome managed with a dual-chamber pacemaker who presented with PCIS after two months of pacemaker implantation. He gradually developed chest discomfort, weakness, tachycardia and paroxysmal nocturnal dyspnea and cardiac tamponade after two months of pacemaker. Post-cardiac injury syndrome related to dual-chamber pacemaker implantation was considered based on exclusion of other possible causes of pericarditis. His therapy was drainage of pericardial fluid and managed with a combination of colchicine and support therapy. He was placed on long-term colchicine therapy to prevent any recurrences. CONCLUSION: This case illustrated that PCIS can occur after minor myocardial injury, and that the possibility of PCIS should be considered if there is a history of possible cardiac insult.


Asunto(s)
Taponamiento Cardíaco , Lesiones Cardíacas , Marcapaso Artificial , Derrame Pericárdico , Pericarditis , Masculino , Humanos , Anciano de 80 o más Años , Marcapaso Artificial/efectos adversos , Pericarditis/diagnóstico , Pericarditis/etiología , Pericarditis/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Derrame Pericárdico/diagnóstico por imagen , Derrame Pericárdico/etiología , Taponamiento Cardíaco/diagnóstico por imagen , Taponamiento Cardíaco/etiología , Taponamiento Cardíaco/terapia
7.
J Cardiovasc Electrophysiol ; 34(6): 1473-1476, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-37222178

RESUMEN

BACKGROUND: Atrial lead perforation may lead to pneumopericardium or pneumothorax within a few days of device implantation. METHODS AND RESULTS: We report a case of atrial lead perforation 6 years after cardiac resynchronization therapy implantation, which resulted in pneumopericardium and pneumothorax. CONCLUSION: Although pneumopericardium caused by atrial lead perforation can spontaneously resolve with conservative treatment, as it did in this case, treatment should be decided based on the patient's general condition and lead performance.


Asunto(s)
Fibrilación Atrial , Lesiones Cardíacas , Marcapaso Artificial , Neumopericardio , Neumotórax , Humanos , Marcapaso Artificial/efectos adversos , Fibrilación Atrial/complicaciones , Neumopericardio/diagnóstico por imagen , Neumopericardio/etiología , Neumopericardio/terapia , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Neumotórax/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia
8.
Anesth Analg ; 136(5): 877-893, 2023 05 01.
Artículo en Inglés | MEDLINE | ID: mdl-37058724

RESUMEN

Cardiac injuries are rare but potentially life-threatening, with a significant proportion of victims dying before arrival at the hospital. The in-hospital mortality among patients who arrive in-hospital alive also remains significantly high, despite major advancements in trauma care including the continuous updating of the Advanced Trauma Life Support (ATLS) program. Stab and gunshot wounds due to assault or self-inflicted injuries are the common causes of penetrating cardiac injuries, while motor vehicular accidents and fall from height are attributable causes of blunt cardiac injury. Rapid transport of victim to trauma care facility, prompt recognition of cardiac trauma by clinical evaluation and focused assessment with sonography for trauma (FAST) examination, quick decision-making to perform emergency department thoracotomy, and/or shifting the patient expeditiously to the operating room for operative intervention with ongoing resuscitation are the key components for a successful outcome in cardiac injury victims with cardiac tamponade or exsanguinating hemorrhage. Blunt cardiac injury with arrhythmias, myocardial dysfunction, or cardiac failure may need continuous cardiac monitoring or anesthetic care for operative procedure of other associated injuries. This mandates a multidisciplinary approach working in concert with agreed local protocols and shared goals. An anesthesiologist has a pivotal role to play as a team leader or member in the trauma pathway of severely injured patients. They are not only involved in in-hospital care as a perioperative physician but also participate in the organizational aspects of prehospital trauma systems and training of prehospital care providers/paramedics. There is sparse literature available on the anesthetic management of cardiac injury (penetrating as well as blunt) patients. This narrative review discusses the comprehensive management of cardiac injury patients, focusing on the anesthetic concerns and is guided by our experience in managing cardiac injury cases at Jai Prakash Narayan Apex Trauma Center (JPNATC), All India Institute of Medical Sciences, New Delhi. JPNATC is the only level 1 trauma center in north India, providing services to a population of approximately 30 million with around 9000 operations being performed annually.


Asunto(s)
Lesiones Cardíacas , Contusiones Miocárdicas , Heridas por Arma de Fuego , Heridas Penetrantes , Humanos , Heridas por Arma de Fuego/cirugía , Heridas Penetrantes/diagnóstico , Heridas Penetrantes/diagnóstico por imagen , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Resucitación , Estudios Retrospectivos
9.
Cardiovasc Revasc Med ; 53S: S209-S212, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-35963835

RESUMEN

Coronary perforation leading to shunting to other cardiac chambers is a rare complication of percutaneous coronary intervention (PCI), and most cases reported aggressive treatment with either a covered stent, coiling, or protamine injection. We report herein two cases, one of a fairly large cavity-spilling perforation of the left anterior descending coronary artery into the right ventricle and one spilling in the coronary vein. Both iatrogenic shunts were treated conservatively, and angiographic follow-up showed spontaneous resolution, suggesting that the outcome in this type of perforation may be favorable with conservative therapy. We also propose a management strategy on how to differentiate such contrast extravasations, find which cavity is communicating with the vessel and when to intervene more decisively. SOCIAL MEDIA ABSTRACT: We report herein two "fortunate" perforations, one of a fairly large cavity-spilling perforation from the left anterior descending coronary artery into the right ventricle and one spilling in the coronary vein. The angiographic follow-up showed spontaneous healing due to spilling in low-pressure cavities. A "no-touch" strategy is preferred if the patient remains asymptomatic and the pericardium free of fluid.


Asunto(s)
Lesiones Cardíacas , Intervención Coronaria Percutánea , Humanos , Intervención Coronaria Percutánea/efectos adversos , Tratamiento Conservador , Resultado del Tratamiento , Vasos Coronarios/diagnóstico por imagen , Angiografía Coronaria , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Stents
10.
Open Heart ; 9(2)2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-36270713

RESUMEN

Coronary perforation is a potentially life-threatening complication of percutaneous coronary intervention (PCI). We studied incidence, outcomes and temporal trends following PCI-related coronary artery perforation (CAP). METHODS: Prospective systematic review and meta-analysis including meta-regression using MEDLINE and EMBASE to November 2020. We included 'all-comer' PCI cohorts including large PCI registries and randomised controlled trials and excluding registries or trials limited to PCI in high-risk populations such as chronic total occlusion PCI or cohorts treated only with atheroablative devices. Regression analysis and corresponding correlation coefficients were performed comparing perforation incidence, mortality rate, tamponade rate and the rate of Ellis III perforations against the midpoint (year) of data collection to determine if a significant temporal relationship was present. RESULTS: 3997 studies were screened for inclusion. 67 studies met eligibility criteria with a total of 5 568 191 PCIs included over a 38-year period (1982-2020). The overall pooled incidence of perforation was 0.39% (95% CI 0.34% to 0.45%) and remained similar throughout the study period. Around 1 in 5 coronary perforations led to tamponade (21.1%). Ellis III perforations are increasing in frequency and account for 43% of all perforations. Perforation mortality has trended lower over the years (7.5%; 95% CI 6.7% to 8.4%). Perforation risk factors derived using meta-regression were female sex, hypertension, chronic kidney disease and previous coronary bypass grafting. Coronary perforation was most frequently caused by distal wire exit (37%) followed by balloon dilation catheters (28%). Covered stents were used to treat 25% of perforations, with emergency cardiac surgery needed in 17%. CONCLUSION: Coronary perforation complicates approximately 1 in 250 PCIs. Ellis III perforations are increasing in incidence although it is unclear whether this is due to reporting bias. Despite this, the overall perforation mortality rate (7.5%) has trended lower in recent years. Limitations of our findings include bias that may be introduced through analysis of multidesign studies and registries without pre-specified standardised perforation reporting CMore research into coronary perforation management including the optimal use of covered stents seems warranted. PROSPERO REGISTRATION NUMBER: CRD42020207881.


Asunto(s)
Lesiones Cardíacas , Intervención Coronaria Percutánea , Femenino , Humanos , Masculino , Intervención Coronaria Percutánea/efectos adversos , Incidencia , Estudios Prospectivos , Lesiones Cardíacas/epidemiología , Lesiones Cardíacas/terapia , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía
11.
Am J Emerg Med ; 61: 152-157, 2022 11.
Artículo en Inglés | MEDLINE | ID: mdl-36116330

RESUMEN

INTRODUCTION: Albeit described since 1763, cardiac contusions is still an under-recognised clinical condition in the acute care setting. This evidence-based review aims to provide an overview of the topic by focusing on etiopathogenesis, classification and clinical presentation of patients with cardiac contusions, as well as on the diagnostic work-up and therapy options available for this subset population in the acute care setting. METHODS: A targeted research strategy was performed using PubMed, MEDLINE, Embase and Cochrane Central databases up to June 2022. The literature search was conducted using the following keywords (in Title and/or Abstract): ("cardiac" OR "heart" OR "myocardial") AND ("contusion"). All available high-quality resources written in English and containing information on epidemiology, etiopathogenesis, clinical findings, diagnosis and management of cardiac contusions were included in our research. RESULTS: Biochemical samples of cardiac troponins together with a 12­lead ECG appear to be sufficient screening tools in hemodynamically stable subjects, while cardiac ultrasound provides a further diagnostic clue for patients with hemodynamic instability or those more likely to have a significant cardiac contusion. CONCLUSIONS: The management of patients with suspected cardiac contusion remains a challenge in clinical practice. For this kind of patients a comprehensive diagnostic approach and a prompt emergency response are required, taking into consideration the degree of severity and clinical impairment of associated traumatic injuries.


Asunto(s)
Contusiones , Lesiones Cardíacas , Contusiones Miocárdicas , Heridas no Penetrantes , Humanos , Heridas no Penetrantes/complicaciones , Contusiones Miocárdicas/complicaciones , Contusiones/diagnóstico , Contusiones/terapia , Contusiones/etiología , Lesiones Cardíacas/diagnóstico , Lesiones Cardíacas/terapia , Lesiones Cardíacas/complicaciones , Troponina
13.
Europace ; 24(11): 1824-1833, 2022 11 22.
Artículo en Inglés | MEDLINE | ID: mdl-35894862

RESUMEN

AIMS: To determine the incidence, clinical features, management, and outcomes of pacemaker (PM) and implantable cardioverter-defibrillator (ICD) lead cardiac perforation. Cardiac perforations due to PM and ICD leads are rare but serious complications. Clinical features vary widely and may cause diagnostic delay. Management strategies are non-guideline based due to paucity of data. METHODS AND RESULTS: A multicentre retrospective series including 3 UK cardiac tertiary centres from 2016 to 2020. Patient, device, and lead characteristics were obtained including 6-month outcomes. Seventy cases of perforation were identified from 10 631 procedures; perforation rate was 0.50% for local implants. Thirty-nine (56%) patients were female, mean ( ± standard deviation) age 74 ( ± 13.8) years. Left ventricular ejection fraction 51 ( ± 13.2) %. Median time to diagnosis was 9 (range: 0-989) days. Computed tomography (CT) diagnosed perforation with 97% sensitivity. Lead parameter abnormalities were present in 86% (whole cohort) and 98.6% for perforations diagnosed >24 h. Chest pain was the commonest symptom, present in 46%. The management strategy was percutaneous in 98.6% with complete procedural success in 98.6%. Pericardial effusion with tamponade was present in 17% and was associated with significantly increased mortality and major complications. Anticoagulation status was associated with tamponade by multivariate analysis (odds ratio 21.7, 95% confidence interval: 1.7-275.5, P = 0.018). CONCLUSIONS: Perforation was rare (0.50%) and managed successfully by a percutaneous strategy with good outcomes. Tamponade was associated with increased mortality and major complications. Anticoagulation status was an independent predictor of tamponade. Case complexity is highly variable and requires skilled operators with a multi-disciplinary approach to achieve good outcomes.


Asunto(s)
Desfibriladores Implantables , Lesiones Cardíacas , Marcapaso Artificial , Humanos , Femenino , Anciano , Masculino , Estudios Retrospectivos , Volumen Sistólico , Diagnóstico Tardío/efectos adversos , Función Ventricular Izquierda , Marcapaso Artificial/efectos adversos , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Desfibriladores Implantables/efectos adversos , Enfermedad Iatrogénica , Anticoagulantes
14.
Catheter Cardiovasc Interv ; 100(2): 190-198, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35686523

RESUMEN

AIM: The impact of Grade III coronary perforations (G3-CP) in the setting of CTO-PCI is not well assessed. METHODS AND RESULTS: We reviewed 7773 CTO-PCI and 98,819 non CTO-PCI performed in 10 European centers: G3 perforation occurred in 87 patients (1.1%) during CTO PCI and 224 patients (0.22%) during non CTO-PCI (p < 0.001). G3-CP involved the CTO segment in 68% of patients and the retrograde channels in 14% of cases. In the CTO PCI group, wire induced G3-CP (50.5% vs. 32.5%, p = 0.02) occurred predominantly when dedicated CTO tapered and highly penetrative wires were used. Intra-procedural and in-hospital death rates were 4.6% vs. 5.8% and 3.6% vs. 7.5% respectively for CTO PCI and non-CTO PCI groups (p = NS). At a median follow up of 24 months, the overall mortality and MAE were respectively 7.8% and MAE 19% without difference among groups. CONCLUSIONS: We showed similar in-hospital and long-term outcomes when G3 perforations occurred during CTO PCI and non CTO-PCI.


Asunto(s)
Enfermedad de la Arteria Coronaria , Oclusión Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Enfermedad Crónica , Angiografía Coronaria , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/terapia , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Mortalidad Hospitalaria , Humanos , Sistema de Registros , Factores de Riesgo , Resultado del Tratamiento , Lesiones del Sistema Vascular/diagnóstico por imagen , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia
15.
Cardiovasc Revasc Med ; 43: 97-101, 2022 10.
Artículo en Inglés | MEDLINE | ID: mdl-35504818

RESUMEN

BACKGROUND/PURPOSE: The PK Papyrus covered coronary stent system (Biotronik AG, Bülach, Switzerland) is intended for treatment of coronary artery perforation (CAP) and is approved for use under a Humanitarian Device Exemption (HDE) in the United States (US). METHODS/MATERIALS: The retrospective data analysis includes cases reported from the US PK Papyrus HDE post-market surveillance clinical dataset with CAP cited as the reason for PK Papyrus stent use. RESULTS: From April 2019 to July 2021, PK Papyrus device registration forms citing CAP as the reason for use were received for 1094 cases from 335 US hospital programs. Ellis classification was assessed as: type III cavity spilling/IV, 11.0%; type III, 57.9%; type II, 23.8%; type I, 7.3%. Mechanisms of perforation included: balloon angioplasty (42.3%), stent placement (31.3%), atherectomy (13.9%), and guidewire (10.9%). The majority (72.6%) of cases involved single covered stent placement. Successful PK Papyrus delivery was reported in 97.7% of cases with successful perforation sealing in 92.1%. Emergency cardiac surgery and in-hospital death occurred in 6.3% and 12.4% of cases, respectively. Pericardiocentesis was performed in 30.2% of patients. Acute/subacute stent thrombosis occurred in 10 patients (1.1%). CONCLUSION: As the largest dataset of patients treated with a covered stent for CAP, these data provide significant insight into patient characteristics, procedural outcome, and in-hospital clinical events associated with this life-threatening complication. These results demonstrate that the PK Papyrus stent is a safe and effective method to seal CAP and with the potential to reduce high morbidity and mortality associated with this event.


Asunto(s)
Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Ensayos de Uso Compasivo/efectos adversos , Enfermedad de la Arteria Coronaria/complicaciones , Vasos Coronarios/diagnóstico por imagen , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Mortalidad Hospitalaria , Humanos , Estudios Retrospectivos , Stents/efectos adversos , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología
16.
Acta Biomater ; 146: 421-433, 2022 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-35545187

RESUMEN

Endothelia progenitor cell (EPC)-based revascularization therapies have shown promise for the treatment of myocardial ischemic injury. However, applications and efficacy are limited by the relatively inefficient recruitment of endogenous EPCs to the ischemic area, while implantation of exogenous EPCs carries the risk of tumorigenicity. In this study, we developed a therapeutic protocol that relies on the capacity of neutrophils (NEs) to target lesions and release preloaded EPC-binding molecules for high efficiency capture. Neutrophils were loaded with superparamagnetic iron oxide nanoparticles conjugated to an antibody against the EPC surface marker CD34 (SPIO-antiCD34/NEs), and the therapeutic efficacy in ischemic mouse heart following SPIO-antiCD34/NEs injection was monitored by SPIO-enhanced magnetic resonance imaging (MRI). These SPIO-antiCD34/NEs exhibited unimpaired cell viability, superoxide generation, and chemotaxis in vitro as well as satisfactory biocompatibility in vivo. In a mouse model of acute myocardial infarction (MI), SPIO-antiCD34 accumulation could be observed 0.5 h after intravenous injection of SPIO-antiCD34/NEs. Moreover, the degree of CD133+ EPC accumulation at MI sites was three-fold higher than in control MI model mice, while ensuing microvessel density was roughly two-fold higher than controls and left ventricular ejection fraction was > 50%. Therapeutic cell biodistribution, MI site targeting, and treatment effects were confirmed by SPIO-enhanced MRI. This study offers a new strategy to improve the endogenous EPC-based myocardial ischemic injury repair through NEs mediated SPIO nanoparticle conjugated CD34 antibody delivery and imaging. STATEMENT OF SIGNIFICANCE: The efficacy of endogenous endothelial progenitor cell (EPC)-based cardiovascular repair therapy for ischemic heart damage is limited by relatively low EPC accumulation at the target site. We have developed a method to improve EPC capture by exploiting the strong targeting ability of neutrophils (NEs) to ischemic inflammatory foci and the capacity of these treated cells to release of preloaded cargo with EPC-binding affinity. Briefly, NEs were loaded with superparamagnetic iron oxide nanoparticles conjugated to an antibody against the EPC surface protein CD34 (SPIO-antiCD34). Thus, we explored sites targeting with nanocomposites cargo for non-invasive EPCs interception and therapy tracking. We demonstrate that SPIO-antiCD34 released from NEs can effectively capture endogenous EPCs and thereby promote heart revascularization and functional recovery in mice. Moreover, the entire process can be monitored by SPIO-enhanced magnetic resonance imaging including therapeutic cell biodistribution, myocardial infarction site targeting, and tissue repair.


Asunto(s)
Células Progenitoras Endoteliales , Lesiones Cardíacas , Infarto del Miocardio , Nanopartículas , Animales , Anticuerpos/metabolismo , Anticuerpos/farmacología , Antígenos CD34/metabolismo , Compuestos Férricos , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/metabolismo , Lesiones Cardíacas/terapia , Ratones , Infarto del Miocardio/diagnóstico por imagen , Infarto del Miocardio/metabolismo , Infarto del Miocardio/terapia , Neutrófilos/metabolismo , Volumen Sistólico , Distribución Tisular , Función Ventricular Izquierda
17.
J Cardiothorac Vasc Anesth ; 36(8 Pt B): 3265-3277, 2022 08.
Artículo en Inglés | MEDLINE | ID: mdl-35305892

RESUMEN

Trauma is the number one cause of death among Americans between the ages of 1 and 46, costing >$670 billion a year. Blunt and penetrating trauma can lead to cardiac and aortic injuries, with the incidence of death varying upon the location of the damage. Among those who reach the hospital alive, many may survive if the hemorrhage and cardiovascular injuries are diagnosed and treated adequately in a timely fashion. Although echocardiography often is underused in the setting of cardiac trauma, it offers significant diagnosis and treatment potential because it is accessible in most settings, safe, relatively noninvasive, and can provide rapid and accurate trauma assessment in the hands of trained providers. This review article aims to analyze the pathophysiology of cardiac injuries in patients with trauma and the role of echocardiography for the accurate diagnosis of cardiac injury in trauma. This review, additionally, will offer a patient-centered, team-based, early management plan with a treatment algorithm to help improve the quality of care among these patients with cardiac trauma.


Asunto(s)
Lesiones Cardíacas , Heridas no Penetrantes , Heridas Penetrantes , Adolescente , Adulto , Niño , Preescolar , Ecocardiografía , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/terapia , Humanos , Lactante , Persona de Mediana Edad , Heridas no Penetrantes/complicaciones , Heridas Penetrantes/complicaciones , Heridas Penetrantes/diagnóstico , Adulto Joven
18.
Expert Rev Cardiovasc Ther ; 20(3): 215-222, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35341445

RESUMEN

INTRODUCTION: Coronary artery perforation is a serious complication during percutaneous coronary intervention that results in significant increase in morbidity and mortality. In this article, we provide a state-of-the-art overview of the contemporary management of coronary perforation and the possible scenarios that operators may run into during percutaneous coronary interventions. AREA COVERED: Coronary perforation during percutaneous coronary intervention. Literature search was performed using PubMed and Google Scholar to identify the most recently published articles covering this topic. EXPERT OPINION: As part of this review, we also provide an expert commentary discussing the nuances in the recognition and management of coronary artery perforation, in addition to future directions, and improvements in technology that could make the management of coronary perforation safer and more effective.


Asunto(s)
Enfermedad de la Arteria Coronaria , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Enfermedad de la Arteria Coronaria/complicaciones , Enfermedad de la Arteria Coronaria/cirugía , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/cirugía , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Humanos , Intervención Coronaria Percutánea/efectos adversos , Intervención Coronaria Percutánea/métodos , Stents/efectos adversos , Resultado del Tratamiento , Lesiones del Sistema Vascular/etiología , Lesiones del Sistema Vascular/terapia
19.
BMC Cardiovasc Disord ; 22(1): 66, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35196989

RESUMEN

BACKGROUND: Coronary artery perforation is a rare but potentially lethal complication of percutaneous coronary intervention (PCI) with an associated mortality of 7-17%. We report the case of coronary artery perforation complicating Absorb bioresorbable vascular scaffold (BVS) implantation and the associated technical challenges with managing this life-threatening complication. CASE REPORT: A 46-year-old male was referred to our institution and underwent PCI with an Absorb bioabsorbable vascular scaffold (BVS) to a proximal LAD long segment bifurcation lesion. Following pre-dilation and deployment of the 3.5 × 28 mm Absorb BVS, high pressure post-dilation of the distal scaffold was complicated by a large, Ellis type III coronary perforation with no flow to the distal LAD beyond the rupture, and associated with a large pericardial effusion confirmed on bedside transthoracic echocardiogram (TTE). The insult was temporised with prolonged balloon inflation within the Absorb BVS immediately proximal to the site of perforation, permitting urgent insertion of a pericardial drain. After deflation of the balloon, a 3.0 × 21 mm BeGraft covered stent was deployed across the perforation, restoring normal LAD flow and abolishing the perforation. Cardio-pulmonary resuscitation was not required and the patient remained conscious throughout the procedure. TTE demonstrated normal left ventricular function and the patient was discharged 3 days later. Repeat angiography at 3 months showed patent stents with TIMI III flow, and optical coherence tomography (OCT) showed good expansion and apposition of the proximal Absorb BVS and BeGraft. The patient has remained well 4 years after PCI with no major cardiovascular events. CONCLUSION: The utility of bioresorbable scaffold technology remains controversial although meticulous implantation techniques are associated with improved clinical outcomes. Adoption of the Pre-dilatation, Sizing and Post-dilatation ('PSP') method of BVS implantation with routine aggressive vessel preparation and scaffold optimization however may contribute to a higher risk of vessel perforation. The case emphasises the importance of accurate sizing of the vessel with intracoronary imaging and demonstrates the value of newer generation covered stents with single-layer design and slimmer crossing profile producing improved deliverability and procedural success.


Asunto(s)
Enfermedad de la Arteria Coronaria , Stents Liberadores de Fármacos , Lesiones Cardíacas , Intervención Coronaria Percutánea , Lesiones del Sistema Vascular , Implantes Absorbibles , Angiografía Coronaria/métodos , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/cirugía , Everolimus , Lesiones Cardíacas/diagnóstico por imagen , Lesiones Cardíacas/etiología , Lesiones Cardíacas/terapia , Humanos , Masculino , Persona de Mediana Edad , Intervención Coronaria Percutánea/efectos adversos , Diseño de Prótesis , Stents , Tomografía de Coherencia Óptica , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...