Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.895
Filtrar
1.
BMC Oral Health ; 24(1): 758, 2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-38956625

RESUMEN

BACKGROUND: The intrusion of maxillary anterior teeth is often required and there are various intrusion modes with mini-implants in clear aligner treatment. The objective of this study was to evaluate the effectiveness of maxillary anterior teeth intrusion with different intrusion modes, aiming to provide references for precise and safe intrusion movements in clinical practice. METHODS: Cone-beam computed tomography and intraoral optical scanning data of a patient were collected. Finite element models of the maxilla, maxillary dentition, periodontal ligaments (PDLs), clear aligner (CA), attachments, and mini-implants were established. Different intrusion modes of the maxillary anterior teeth were simulated by changing the mini-implant site (between central incisors, between central and lateral incisor, between lateral incisor and canine), loading site (between central incisors, on central incisor, between central and lateral incisor, between lateral incisor and canine), and loading mode (labial loading and labiolingual loading). Ten conditions were generated and intrusive forces of 100 g were applied totally. Then displacement tendency of the maxillary anterior teeth and CA, and stress of the PDLs were analyzed. RESULTS: For the central incisor under condition L14 and for the canine under conditions L11, L13, L23, and L33, the intrusion amount was negative. Under other conditions, the intrusion amount was positive. The labiolingual angulation of maxillary anterior teeth exhibited positive changes under all conditions, with greater changes under linguoincisal loading. The mesiodistal angulation of canine exhibited positive changes under labial loading, while negative changes under linguoincisal loading except for condition L14. CONCLUSIONS: The intrusion amount, labiolingual and mesiodistal angulations of the maxillary anterior teeth were affected by the mini-implant site, loading site, and loading mode. Labial and linguoincisal loading may have opposite effects on the intrusion amount of maxillary anterior teeth and the mesiodistal angulation of canine. The labiolingual angulation of the maxillary incisors would increase under all intrusion modes, with greater increases under linguoincisal loading.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Implantes Dentales , Análisis de Elementos Finitos , Incisivo , Maxilar , Métodos de Anclaje en Ortodoncia , Ligamento Periodontal , Técnicas de Movimiento Dental , Humanos , Técnicas de Movimiento Dental/métodos , Técnicas de Movimiento Dental/instrumentación , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Ligamento Periodontal/diagnóstico por imagen , Imagenología Tridimensional/métodos , Diente Canino/diagnóstico por imagen , Diseño de Aparato Ortodóncico , Análisis del Estrés Dental , Fenómenos Biomecánicos , Aparatos Ortodóncicos Removibles
2.
Eur J Orthod ; 46(4)2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39011819

RESUMEN

BACKGROUND: Extraction space closure is a challenging phase during orthodontic treatment that affects not only the total treatment duration but also the whole treatment outcome. OBJECTIVE: To compare the efficiency of friction and frictionless mechanics during en-masse retraction of maxillary anterior teeth in adult patients with bimaxillary dentoalveolar protrusion. TRIAL DESIGN: Two-arm parallel group, single-center randomized clinical trial. MATERIALS AND METHODS: Thirty-two adult patients with bimaxillary protrusion were recruited and randomly allocated to two different retraction mechanics. A friction group, using NiTi coil springs and a frictionless group using closing T-loops for en-masse retraction. Randomization in a 1:1 ratio was generated by Microsoft Excel. The randomization numbers were secured in opaque sealed envelopes for allocation concealment. Retraction started in all patients following first premolars extraction using miniscrews as a source of indirect anchorage. Activation was done on a monthly basis until complete retraction of anterior segment. The rate of retraction, amount of anchorage loss, the dental, and soft tissue changes were analyzed on digital models and lateral cephalograms taken before retraction and after space closure. BLINDING: The outcome assessor was blinded through data concealment during assessment. RESULTS: Two patients were lost to follow up, so 30 patients completed the trial. The rate of anterior segment retraction was 0.88 ±â€…0.66 mm/month in the frictionless group compared to 0.72 ±â€…0.36 mm/month in the friction group which was statistically significant. Anchorage loss of 1.18 ±â€…0.72 mm in the friction group compared to 1.29 ±â€…0.55 mm in the frictionless group with no significant difference. Comparable dental and soft tissue changes following en-masse retraction were reported in both groups, with no statistically significant difference. HARM: one patient complained of soft tissue swelling following miniscrew insertion, but the swelling disappeared after one week of using mouth wash. LIMITATION: The study focused only on the maxillary arch. CONCLUSION: Both mechanics have successfully achieved the required treatment objectives in patients with bimaxillary dentoalveolar protrusion. Frictionless group showed a faster rate of retraction than the friction group, which was statistically but not clinically significant. TRIAL REGISTRATION: Clinicaltrials.gov with the identifier NCT03261024.


Asunto(s)
Fricción , Maxilar , Técnicas de Movimiento Dental , Humanos , Masculino , Femenino , Adulto , Técnicas de Movimiento Dental/métodos , Técnicas de Movimiento Dental/instrumentación , Adulto Joven , Cierre del Espacio Ortodóncico/métodos , Cierre del Espacio Ortodóncico/instrumentación , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Maloclusión Clase I de Angle/terapia , Maloclusión Clase I de Angle/fisiopatología , Diseño de Aparato Ortodóncico , Alambres para Ortodoncia , Cefalometría/métodos , Resultado del Tratamiento , Níquel , Titanio
3.
Biomed Phys Eng Express ; 10(5)2024 Jul 19.
Artículo en Inglés | MEDLINE | ID: mdl-38986445

RESUMEN

Miniscrews are widely used in orthodontics as an anchorage device while aligning teeth. Shear stress in the miniscrew-bone interface is an important factor when the miniscrew makes contact with the bone. The objective of this study was to analyze the shear stress and force in the screw-bone interface for varying Cortical Bone Thickness (CBT) using Finite Element Analysis (FEA). Varying CBT of 1.09 mm (1.09CBT) and 2.66 mm (2.66CBT) with miniscrews of Ø1.2 mm, 10 mm length (T1), Ø1.2 mm, 6 mm length (T2) and Ø1.6 mm, 8 mm length (T3) were analyzed. Six Finite Element (FE) models were developed with cortical, cancellous bone, miniscrews and gingiva as a prism. A deflection of 0.1 mm was applied on the neck of the miniscrews at 0°, +30° and -30° angles. The shear stress and force in the screw-bone interface were assessed. The results showed that the CBT affects the shear stress and force in the screw-bone interface region in addition to the screw dimensions and deflection angulations. T1 screw generated lesser shear stress in 1.09CBTand 2.66CBTcompared to T2 and T3 screws. Higher CBT is preferred for better primary stability in shear aspect. Clinically applied forces of 200 gms to 300 gms to an anchorage device induces shear stress in the miniscrew-bone interface region might cause stress shielding. Thus, clinicians need to consider the effect of varying CBT and the size of the miniscrews for the stability, reduced stress shielding and better anchorage during orthodontic treatment.


Asunto(s)
Tornillos Óseos , Hueso Cortical , Análisis de Elementos Finitos , Métodos de Anclaje en Ortodoncia , Resistencia al Corte , Estrés Mecánico , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Fenómenos Biomecánicos , Encía , Simulación por Computador , Hueso Esponjoso
4.
Dental Press J Orthod ; 29(2): e2423253, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38865515

RESUMEN

OBJECTIVE: To assess the effectiveness of a customized distalizer with Variety SP® screws anchored on palatal miniscrews for upper molar distalization. METHODS: Seventeen patients aged between 12.5 and 24 years underwent distalization with a customized distalizer. Lateral cephalogram and cast analysis were performed before and after distalization. Linear and angular parameters of the upper first molar, first premolar, and central incisor were assessed. RESULTS: Distalization with the force passing near the center of resistance (CRes) of the upper first molars resulted in distal movement, with minimal distal tipping (2.8 ±â€Š0.45°, p< 0.05). However, distalization passing occlusal to the CRes led to greater distal tipping (13.6 ±â€Š1.63°, p< 0.05). Statistically significant spontaneous distal tipping and distal movement of the upper first premolars occurred, with a mean of 6.2 ±â€Š1.24° (p< 0.05) and 0.68 ±â€Š0.34 mm (p< 0.05), respectively. The positional change of the upper central incisors presented a mean of -0.23 ±â€Š0.1 mm (p> 0.05) and 2.65 ±â€Š1.1° (p< 0.05). Upper first molar intrusion was statistically significant, with a mean of 0.88 ±â€Š0.2 mm (p< 0.05). Upper right and left first molars rotation towards palatal midline presented mean of 4.1 ±â€Š0.19° (p< 0.05) and 3.4  ±â€Š0.1° (p< 0.05), respectively. Additionally, the distance between upper right and left first molars increased significantly, with a mean of 2.54 ±â€Š0.01 mm (p< 0.05). CONCLUSION: The study successfully demonstrated the efficiency of molar distalization without anchorage loss using a customized distalizer anchored on palatal miniscrews.


Asunto(s)
Tornillos Óseos , Cefalometría , Diente Molar , Métodos de Anclaje en Ortodoncia , Diseño de Aparato Ortodóncico , Técnicas de Movimiento Dental , Humanos , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Adolescente , Niño , Adulto Joven , Femenino , Masculino , Maxilar/cirugía , Diente Premolar , Incisivo , Modelos Dentales
7.
Ann Ital Chir ; 95(3): 374-381, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38918968

RESUMEN

AIM: Chronic periodontitis leads to gingival swelling, hyperplasia, and tooth mobility, which affects orthodontic treatment. The aim of this study was to investigate the application of cefaclor in orthodontics through micro-implant anchorage in patients with periodontitis. METHODS: A retrospective study was conducted on patients with periodontitis who received micro-implant anchorage treatment in the department of orthodontics at the First People's Hospital of Yongkang City from July 2019 to January 2022. According to different treatment regimens, these patients were divided into the test group (patients receiving cefaclor and micro-implant anchorage treatment) and the control group (patients receiving micro-implant anchorage treatment only). The plaque index (PLI), gingival index (GI), sulcus bleeding index (SBI), and serum inflammatory factor levels were compared between the two groups after treatment. RESULTS: One hundred and five patients were included in the study, (44 males and 61 females, median age 21 [15-25] years), 51 in the cefaclor group and 54 in the no cefaclor group. After treatment, the PLI, GI, and SBI scores in the two groups were higher than those before treatment, and the levels of serum inflammatory markers significantly increased (p < 0.05). After treatment, the PLI, GI, and SBI scores in the test group were significantly lower than those in the control group (p < 0.001). The levels of serum interleukin-1ß, interleukin-6, interleukin-8, and tumor necrosis factor-α were significantly lower in the test group, and the interleukin-2 level was higher in the test group (p < 0.001). There was no significant difference in the incidence of complications between the two groups (p > 0.05). CONCLUSIONS: Cefaclor and micro-implant anchorage have a good clinical effect on orthodontics in patients with periodontitis, improving periodontal health and reducing inflammatory response.


Asunto(s)
Cefaclor , Humanos , Femenino , Masculino , Estudios Retrospectivos , Adulto , Cefaclor/uso terapéutico , Adulto Joven , Adolescente , Antibacterianos/uso terapéutico , Métodos de Anclaje en Ortodoncia , Índice Periodontal , Periodontitis Crónica/complicaciones , Periodontitis Crónica/terapia , Periodontitis Crónica/tratamiento farmacológico , Periodontitis Crónica/sangre , Implantes Dentales
8.
Indian J Dent Res ; 35(1): 98-100, 2024 Jan 01.
Artículo en Inglés | MEDLINE | ID: mdl-38934757

RESUMEN

INTRODUCTION: During orthodontic treatment, temporary anchoring devices (TADs) are used to restrain tooth movement. They are a relatively recent addition to the dental toolkit. AIM: As TADs have limitations, Dr. Eric Lieu of Taiwan developed Infra Zygomatic Crest (IZC) screws which are placed between the maxillary second premolar at the bony crest. TREATMENT PLANNING: The goal of this case study is to emphasize the value of anatomy, site selection, and IZC retrieval in the event of an accident. Cone beam computed tomography was used as a diagnostic tool for the precise location of the displaced IZC and immediate surgical retrieval was done under local anesthesia from the infratemporal space to prevent further complications. TAKEAWAY LESSONS: Orthodontists knowledge of soft tissue and hard tissue anatomy and precise positioning is crucial for successful TAD implantation.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Métodos de Anclaje en Ortodoncia , Cigoma , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Cigoma/cirugía , Cigoma/diagnóstico por imagen , Tornillos Óseos , Masculino , Femenino , Diente Premolar/diagnóstico por imagen , Maxilar/cirugía , Técnicas de Movimiento Dental/métodos , Técnicas de Movimiento Dental/instrumentación
9.
J Dent ; 146: 105060, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38735471

RESUMEN

OBJECTIVES: Temporary anchorage devices (TADs) have become an integral part of comprehensive orthodontic treatments. This study evaluated the transfer accuracy of three-dimensional (3D) printed and computer-aided design/computer-aided manufacturing (CAD/CAM) milled surgical guides for orthodontic TADs using micro-computed tomography (CT) imaging in a preclinical trial. METHODS: Overall, 30 surgical guides were used to place TADs into typodonts; 3D printing and CAD/CAM milling were used to produce the guides. The virtual target positions of the TADs were compared to the real positions in terms of spatial and angular deviations using digital superimposition. Micro-CT imaging was used to detect the positions. To evaluate reliability, two investigators collected the measurements twice. Intra-rater and inter-rater correlations were tested. RESULTS: In total, 60 palatal TADs were evaluated. The mean coronal deviations in the print group ranged from 0.15 ± 0.20 mm to 0.71 ± 0.22 mm, whereas in the mill group, they ranged from 0.09 ± 0.15 mm to 0.83 ± 0.23 mm. At the apical tip, the overall deviations in the print group ranged from 0.14 ± 0.56 mm to 1.27 ± 0.66 mm, whereas in the mill group, they ranged from 0.15 ± 0.57 mm to 1.09 ± 0.44 mm. The mean intra-class and inter-class correlation coefficients ranged from 0.904 to 0.987. No statistically significant differences were found between the groups. CONCLUSIONS: CAD/CAM milled guides yielded spatial and angular accuracies comparable to those of 3D printed guides with notable deviations in the vertical positioning of TADs. CLINICAL SIGNIFICANCE: Digital planning of orthodontic temporary implants combines clinical predictability and the safety of surrounding tissue. Therefore, the transfer accuracy of the guides is crucial. This preclinical study was the first to evaluate CAD/CAM milling for orthodontic guides and found its accuracy comparable to that of the current "gold standard".


Asunto(s)
Diseño Asistido por Computadora , Impresión Tridimensional , Microtomografía por Rayos X , Microtomografía por Rayos X/métodos , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Reproducibilidad de los Resultados , Implantes Dentales , Cirugía Asistida por Computador/métodos , Imagenología Tridimensional/métodos
11.
J Dent ; 146: 105093, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38788916

RESUMEN

OBJECTIVES: The aim of this study was to evaluate the influence of palatal vault morphology and screw length on the accuracy of miniscrew insertion in dynamic computer-assisted surgery (d-CAS). METHODS: Twenty-four subjects were allocated into three groups, according to their palatal vault morphology (Group A: medium; Group B: steep/high; Group C: low/flat) and the length of miniscrew used. For each subject, two miniscrews were inserted using a dynamic navigation system. To assess the accuracy of insertion, a postoperative CBCT was performed, and the pre- and post-operative scans were superimposed. Five variables were evaluated: Entry-3D, Entry-2D, Apex-3D, Apex-vertical and angular deviation. Descriptive statistics, Shapiro-wilk, Kruskal-Wallis and Dunn's tests were used for the statistical analysis. The level of significance was P ≤ 0.05. RESULTS: The mean angular deviation values revealed strong discrepancies amongst the groups (Group A:7.11°±5.70°; Group B:13.30°±7.76°; Group C:4.92°±3.15°) and significant differences were found regarding the Apex-3D (P = 0.036) and angular deviations (P = 0.008). A Dunn's test revealed differences in angular deviation between the medium and high/steep palate group (P = 0.004), and between low/flat and high/steep palate group (P = 0.01) but did not confirm any significant difference in the Apex-3D parameter (Group A-B P = 0.10; Group B-C, P = 0.053; Group A-C, P = 1.00). No significant differences were found regarding the length of the miniscrews. CONCLUSIONS: Palatal vault morphology is a factor that influences the accuracy of miniscrew insertion in d-CAS. In subjects with steep and high palatal vaults, insertion accuracy is lower when considering the angular deviation value. Miniscrew length does not influence accuracy. CLINICAL SIGNIFICANCE: Although computer-guided surgery assists the clinician in preventing damage to nearby anatomical structures, individual anatomical variability is a crucial variable. In subjects with a high/steep palate, greater attention should be paid during the planning phase in order to allow for a wide margin from adjacent anatomical structures to achieve better outcomes.


Asunto(s)
Tornillos Óseos , Tomografía Computarizada de Haz Cónico , Métodos de Anclaje en Ortodoncia , Hueso Paladar , Cirugía Asistida por Computador , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Estudios Prospectivos , Cirugía Asistida por Computador/métodos , Masculino , Femenino , Adulto Joven , Adulto , Hueso Paladar/diagnóstico por imagen , Hueso Paladar/anatomía & histología , Adolescente , Paladar Duro/diagnóstico por imagen , Paladar Duro/anatomía & histología , Paladar Duro/cirugía , Imagenología Tridimensional/métodos , Maxilar/diagnóstico por imagen , Maxilar/cirugía , Procesamiento de Imagen Asistido por Computador/métodos , Cefalometría/métodos
12.
Dent Med Probl ; 61(3): 363-371, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38808382

RESUMEN

BACKGROUND: The morphology of the nasopalatine canal is crucial in the planning of prosthetic restorations in the anterior region of the maxilla, as well as in the placement of orthodontic mini-implants. OBJECTIVES: The aim of this study was to assess the morphology of the nasopalatine canal using cone beam computed tomography (CBCT) scans of patients from the University Dental Clinic in Krakow, Poland, to define the position of the canal in relation to common sites of palatal median microimplant placement, and to investigate potential correlations between the anatomy of the canal and age and gender of the patients. MATERIAL AND METHODS: A total of 120 CBCT images were used to assess the anatomy of the nasopalatine canal in 3 planes of space. The bone thickness anterior to the nasopalatine canal and the distance between the distal margin of Stenson's foramen and the predicted midpalatal microimplant position were also measured. RESULTS: The most frequently observed canal type in the coronal plane was the Y-shaped canal, which was present in 60.8% of patients. The nasopalatine canal was classified as cone-shaped in 31.7% of the scans, cylindrical in 28.3%, hourglass-shaped in 27.5%, and banana-shaped in 12.5%. The mean length of the nasopalatine canal was 11.58 mm. The mean width of the canal was 2.89 mm at the nasal fossa level, 1.94 mm in the middle, and 5.09 mm at the palatal level. The mean bone thickness anterior to the nasopalatine canal was 9.07 mm at the level of the nasal opening, 6.84 mm at the level of the oral opening, and 7.32 mm in the middle. The mean distance between the distal margin of Stenson's foramen and the predicted midpalatal microimplant position varied from 0 to 11.94 mm, with a mean of 2.49 mm. CONCLUSIONS: Given the variety of nasopalatine canal forms and dimensions, detailed analysis of CBCT scans is essential prior to the placement of implants and microimplants.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Humanos , Masculino , Femenino , Adulto , Métodos de Anclaje en Ortodoncia/instrumentación , Maxilar/diagnóstico por imagen , Maxilar/anatomía & histología , Persona de Mediana Edad , Adolescente , Tornillos Óseos , Adulto Joven , Hueso Paladar/diagnóstico por imagen , Hueso Paladar/anatomía & histología , Paladar Duro/diagnóstico por imagen , Paladar Duro/anatomía & histología
14.
Eur J Orthod ; 46(3)2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38733349

RESUMEN

OBJECTIVES: The biomechanics in achieving molar distalization may differ between fixed appliances and clear aligners in the control of tooth movement. The objective of this study was to compare the treatment effects between clear aligners (CA) and fixed appliances (FA) in patients treated with miniscrew-assisted molar distalization. METHODS: The sample consisted of 46 subjects with mild-to-moderate crowding. A total of 22 patients treated with clear aligners (age, 25.66 ±â€…6.11 years old) and 24 patients treated with fixed appliances (age, 24.04 ±â€…4.95 years old) for miniscrew-assisted molar distalization were included in this study. The dental and skeletal changes were evaluated by the pre- and post-treatment lateral cephalograms. RESULTS: Significant changes were found with the vertical variables SN-OP angle (2.24 ±â€…3.22°, P < .05) and SN-MP angle (0.73 ±â€…1.15°, P < .05) for the FA group when compared with the CA group (SN-OP angle 0.41 ±â€…2.26° and SN-MP angle -0.21 ±â€…1.38°, P > .05). Both treatment groups achieved a 2-3 mm. molar distalization with significant intrusion of the upper molars. The CA group showed significantly less distal tipping of molars (U6^PP angle -2.29 ±â€…3.29° and L6^MP angle -2.92 ±â€…2.49°, P < .05) compared to the FA group (-5.24 ±â€…4.28° and -5.53 ±â€…5.03°, P < .05). In addition, significant retraction and lingual inclination of the upper and lower incisors were found in both groups. LIMITATIONS: The changes of tooth position were evaluated by 2D lateral cephalograms, not 3D measurements. CONCLUSIONS: Compared to fixed appliances, clear aligners seemed to have better control of vertical dimension and distal tipping of molars in patients treated with miniscrew-assisted molar distalization.


Asunto(s)
Tornillos Óseos , Cefalometría , Diente Molar , Métodos de Anclaje en Ortodoncia , Aparatos Ortodóncicos Fijos , Técnicas de Movimiento Dental , Humanos , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Masculino , Femenino , Adulto , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Adulto Joven , Diseño de Aparato Ortodóncico , Maloclusión/terapia , Resultado del Tratamiento , Maxilar , Mandíbula , Aparatos Ortodóncicos Removibles , Incisivo , Dimensión Vertical
15.
Prog Orthod ; 25(1): 19, 2024 May 27.
Artículo en Inglés | MEDLINE | ID: mdl-38797777

RESUMEN

BACKGROUND: Skeletal anterior open bite (SAOB) represents one of the most complex and challenging malocclusions in orthodontics. Orthodontic treatment supported by miniplates enable to reduce the need for orthognathic surgery. Transverse dimension may be affected by intrusion biomechanics. This study aims to assess transverse bone alterations in patients with SAOB who underwent orthodontic treatment with absolute anchorage using four miniplates. METHODS: A total of 32 patients of both sexes, with an average age of 33.8 years, diagnosed with SAOB and treated orthodontically with four miniplates (one in each hemiarch), were selected for this study. Tomographic examinations were performed before (T1) and after (T2) orthodontic treatment. Linear measurements (width of the maxillary base, maxillary alveolar, maxillary root, maxillary dental cusp, mandibular alveolar) and angular measurements (maxillary intermolar angle) were assessed in these images. The Shapiro-Wilks normality tests were applied to verify data distribution, and the paired t-test was used to compare the initial and final measures obtained. RESULTS: Among the evaluated parameters, the maxillary alveolar width, maxillary dental cusp width, mandibular alveolar cusp width, and intermolar angle showed statistically significant differences between T1 and T2 (p < 0.05). However, maxillary base and maxillary root widths showed no significant difference (p > 0.05). CONCLUSIONS: Intrusion and distalization with miniplates in SAOB therapy may lead to significant expansive changes, due to molars cusps width and buccal inclination increase restricted at the alveolar level.


Asunto(s)
Placas Óseas , Mandíbula , Mordida Abierta , Métodos de Anclaje en Ortodoncia , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Masculino , Femenino , Mordida Abierta/terapia , Mordida Abierta/diagnóstico por imagen , Adulto , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen , Cefalometría , Proceso Alveolar/diagnóstico por imagen , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Tomografía Computarizada por Rayos X/métodos , Adulto Joven , Diseño de Aparato Ortodóncico
16.
Head Face Med ; 20(1): 31, 2024 May 14.
Artículo en Inglés | MEDLINE | ID: mdl-38745246

RESUMEN

BACKGROUND: In this study, we sought to quantify the influence of vertical control assisted by a temporary anchorage device (TAD) on orthodontic treatment efficacy for skeletal class II patients with a hyperdivergent facial type and probe into the critical factors of profile improvement. METHODS: A total of 36 adult patients with skeletal class II and a hyperdivergent facial type were included in this retrospective case-control study. To exclude the effect of sagittal anchorage reinforcement, the patients were divided into two groups: a maxillary maximum anchorage (MMA) group (N = 17), in which TADs were only used to help with anterior tooth retraction, and the MMA with vertical control (MMA + VC) group (N = 19), for which TADs were also used to intrude the maxillary molars and incisors. The treatment outcome was evaluated using dental, skeletal, and soft-tissue-related parameters via a cephalometric analysis and cast superimposition. RESULTS: A significant decrease in ANB (P < 0.05 for both groups), the retraction and uprighting of the maxillary and mandibular incisors, and the retraction of protruded upper and lower lips were observed in both groups. Moreover, a significant intrusion of the maxillary molars was observed via the cephalometric analysis (- 1.56 ± 1.52 mm, P < 0.05) and cast superimposition (- 2.25 ± 1.03 mm, P < 0.05) of the MMA + VC group but not the MMA group, which resulted in a remarkable decrease in the mandibular plane angle (- 1.82 ± 1.38°, P < 0.05). The Z angle (15.25 ± 5.30°, P < 0.05) and Chin thickness (- 0.97 ± 0.45°, P < 0.05) also improved dramatically in the MMA + VC group, indicating a better profile and a relaxed mentalis. Multivariate regression showed that the improvement in the soft tissue was closely related to the counterclockwise rotation of the mandible plane (P < 0.05). CONCLUSIONS: TAD-assisted vertical control can achieve intrusion of approximately 2 mm for the upper first molars and induce mandibular counterclockwise rotation of approximately 1.8°. Moreover, it is especially important for patients without sufficient retraction of the upper incisors or a satisfactory chin shape.


Asunto(s)
Cefalometría , Maloclusión Clase II de Angle , Humanos , Maloclusión Clase II de Angle/terapia , Maloclusión Clase II de Angle/diagnóstico por imagen , Femenino , Masculino , Estudios Retrospectivos , Adulto , Estudios de Casos y Controles , Adulto Joven , Resultado del Tratamiento , Métodos de Anclaje en Ortodoncia/métodos , Métodos de Anclaje en Ortodoncia/instrumentación , Ortodoncia Correctiva/métodos , Técnicas de Movimiento Dental/métodos , Dimensión Vertical , Adolescente
17.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38775601

RESUMEN

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Asunto(s)
Aleaciones Dentales , Implantes Dentales , Resistencia Flexional , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Métodos de Anclaje en Ortodoncia , Acero Inoxidable , Propiedades de Superficie , Titanio , Torque , Titanio/química , Acero Inoxidable/química , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Aleaciones Dentales/química , Técnicas In Vitro , Espectrometría por Rayos X , Análisis del Estrés Dental , Humanos , Estrés Mecánico , Densidad Ósea
18.
Stomatologiia (Mosk) ; 103(2): 61-70, 2024.
Artículo en Ruso | MEDLINE | ID: mdl-38741537

RESUMEN

OBJECTIVE: Prevention of the development of pronounced skeletal abnormalities in patients with mesial occlusion. MATERIALS AND METHODS: Biometric analysis of control and diagnostic models of dentition was performed in 60 patients with dental anomalies before and after treatment in 3 mutually perpendicular planes to identify violations in the formation of dental arches by sagittal and transversal dimensions, and alveolar processes - by vertical dimensions (methods of A. Pont, G. Korkhaus). Measurements of 23 parameters of TRG and sections of CBCT were carried out using the modified Nad-Ars technique with analysis of skeletal parameters before and after treatment. Treatment was carried out using dilators for the upper jaw in combination with a facial mask and further dynamic observation using active retention devices. RESULTS: The results of treatment showed an increase in the length of the anterior segment of the upper dental arch by 2.8±0.55 mm (p<0.05 mm); expansion in the area of temporary molars by 2.85±0.65 mm (p<0.05); in the area of permanent molars by 2.75±0.55 mm (p<0.05); in the area of the apical basis of HF by 3.82±0.45 mm (p<0.05). The length of the lower dental arch in the anterior segment has not changed. Analysis of TRG parameters showed a significant increase in the values of

Asunto(s)
Arco Dental , Humanos , Niño , Masculino , Femenino , Arco Dental/diagnóstico por imagen , Maloclusión/terapia , Técnica de Expansión Palatina/instrumentación , Tornillos Óseos , Oclusión Dental , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Adolescente , Aparatos Ortodóncicos Fijos
19.
J World Fed Orthod ; 13(3): 105-112, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38697910

RESUMEN

Posterior Crossbite is a common condition resulting because of transverse maxillary deficiency. The growth of the craniofacial complex finishes first in the transverse dimension, followed by sagittal and vertical dimensions. Conventional rapid palatal expansion (RPE) appliances are commonly used to correct transverse maxillary deficiency. Although RPE is efficient in correcting posterior crossbite, it results in dental side effects such as buccal tipping of maxillary molars, root resorption, bone dehiscence, and relapse. Mini-implant-assisted RPE has been introduced to increase the skeletal effects of expansion especially in patients with increased maturation and greater interdigitation of midpalatal suture. This article will review the biomechanics of RPE and mini-implant-assisted RPE. Additionally, the different designs of MARPE and the long-term clinical effects of expansion appliances will also be discussed in detail.


Asunto(s)
Tornillos Óseos , Métodos de Anclaje en Ortodoncia , Técnica de Expansión Palatina , Técnica de Expansión Palatina/instrumentación , Humanos , Fenómenos Biomecánicos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Diseño de Aparato Ortodóncico , Maloclusión/terapia , Maxilar
20.
Am J Orthod Dentofacial Orthop ; 166(1): 69-75, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38647514

RESUMEN

INTRODUCTION: The objective of this study was to investigate the accuracy of palatal miniscrew insertion, evaluating the effect of guide fabrication and surgical placement. METHODS: Guided insertion of bilateral paramedian palatal miniscrews was undertaken using Appliance Designer software (3Shape, Copenhagen, Denmark). A resin surgical guide (P Pro Surgical Guide; Straumann AG, Basel, Switzerland) was used. Superimposition of the miniscrew position relative to the digital design was undertaken using bespoke software (Inspect 3D module, OnyxCeph; Image Instruments GmbH, Chemnitz, Germany) to assess surgical inaccuracy. Miniscrew position relative to the surgical guide was also assessed to isolate the effect of planning inaccuracies. Both horizontal and vertical discrepancies were evaluated at both implant locations. RESULTS: Twenty-seven patients having bilateral palatal insertions were examined. Mean discrepancies were <0.5 mm, both in the horizontal and vertical planes. The mean overall horizontal and vertical discrepancy between the digital design and final miniscrew position on the left side was 0.32 ± 0.15 mm and 0.34 ± 0.17 mm, respectively. The maximum horizontal discrepancy observed was 0.72 mm. No significant differences were observed in relation to the accuracy of mini-implant positioning on the basis of sidedness, either for horizontal (P = 0.29) or vertical (P = 0.86) discrepancy. CONCLUSIONS: High levels of accuracy associated with guided insertion of paramedian palatal implants were recorded with mean discrepancies of less than 0.5 mm both in the horizontal and vertical planes. No difference in accuracy was noted between the left and right sides. Very minor levels of inaccuracy associated both with surgical techniques and surgical guide fabrication were recorded.


Asunto(s)
Tornillos Óseos , Métodos de Anclaje en Ortodoncia , Humanos , Métodos de Anclaje en Ortodoncia/instrumentación , Métodos de Anclaje en Ortodoncia/métodos , Femenino , Masculino , Cirugía Asistida por Computador/métodos , Hueso Paladar/cirugía , Planificación de Atención al Paciente , Adolescente , Adulto , Adulto Joven , Diseño Asistido por Computadora , Imagenología Tridimensional/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...