Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 13.072
Filtrar
1.
JCO Glob Oncol ; 10: e2400005, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38723214

RESUMEN

PURPOSE: Disparities in cervical cancer screening, incidence, and mortality exist in the United States. Cervical cancer incidence and mortality rates in Texas are 20% and 32% higher, respectively, than national averages. Within Texas, these rates are significantly higher among non-Hispanic (NH) Black and Hispanic women. Cervical cancer screening uptake is lower among NH Black and Hispanic women (72.9% and 75.9%, respectively) compared with White women (85.5%) in Texas. METHODS: During March-August 2023, we conducted a pilot study that offered culturally competent education and human papillomavirus (HPV) self-sampling kits to women in two public housing projects in Houston, TX, that have predominantly NH Black or Hispanic residents. Among those eligible for cervical cancer screening, 35% (n = 24) of the NH Black and 34% (n = 16) of the Hispanic women were found to be underscreened per the US Preventive Services Task Force Guideline. We recruited 40 (24 NH Black and 16 Hispanic) eligible women for our study. The study was approved by the MD Anderson institutional review board and registered with ClinicalTrials.gov (NCT04614155-March 11, 2020). RESULTS: Seventy-five percent of the NH Black and 87% of the Hispanic participants completed the HPV self-sampling procedures per protocol. Samples of 17% NH Black and 12% Hispanic participants showed a performance error. Overall, cervical cancer screening uptake improved from 65% to 91% among NH Black and from 66% to 96% among Hispanic participants. CONCLUSION: Culturally competent education and HPV self-sampling resulted in remarkable improvement in cervical cancer screening uptake among underscreened NH Black and Hispanic women residents of Houston public housing projects. Implementing this strategy could significantly reduce cervical cancer incidence and mortality among similar populations in the United States and globally.


Asunto(s)
Detección Precoz del Cáncer , Hispánicos o Latinos , Infecciones por Papillomavirus , Neoplasias del Cuello Uterino , Humanos , Femenino , Hispánicos o Latinos/estadística & datos numéricos , Neoplasias del Cuello Uterino/diagnóstico , Neoplasias del Cuello Uterino/virología , Neoplasias del Cuello Uterino/prevención & control , Adulto , Detección Precoz del Cáncer/métodos , Infecciones por Papillomavirus/diagnóstico , Persona de Mediana Edad , Texas/epidemiología , Proyectos Piloto , Pobreza , Negro o Afroamericano/estadística & datos numéricos , Papillomaviridae/aislamiento & purificación , Competencia Cultural , Manejo de Especímenes/métodos , Virus del Papiloma Humano
2.
PLoS One ; 19(5): e0302785, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38768150

RESUMEN

INTRODUCTION: The rates of gonorrhea and chlamydia have been increasing in the years preceding the COVID19 pandemic. Because most gonorrhea and chlamydia infections are located in the oropharynx and rectum for men who have sex with men (MSM), and because at-home self-collected swabs for these infections are not licensed by Health Canada or the United States Food and Drug Administration, decreased accessed to in-person care during and since the COVID19 pandemic potentially means missed case findings. OBJECTIVES: To evaluate the performance of at-home self-collected pharyngeal and rectal swabs for gonorrhea and chlamydia nucleic acid amplification testing. METHODOLOGY: All persons who contacted our Sexual Health Clinic and who had a clinical indication to complete oral and/or rectal swabs for gonorrhea and chlamydia were invited to complete at-home swabs in advance of their scheduled appointments. We mailed swabs and instructions to those who consented. Participants brought these swabs to their scheduled in clinic appointments, where we repeated the same swabs. All matching swabs were sent to the laboratory for analysis to determine concordance. RESULTS: From September 8, 2022 to July 18, 2023, we enrolled 296 eligible participants who provided 1184 swabs. For analysis, cancelled specimens and specimens with invalid results were excluded, leaving 1032 swabs for comparison. We identified 66 STI diagnoses in 47 unique participants. Overall accuracy was high (exceeding 99%), except for rectal chlamydia, which was 96.0%. While the performance of self-swabs for chlamydia was lower compared to gonorrhea, at-home swabs identified six chlamydia infections that were missed by in-clinic collected swabs (two pharyngeal, four rectal). Removing these six cases as "false positives" increased overall accuracy for chlamydia detection to 99.7% (pharyngeal) and 97.8% (rectal). CONCLUSION: Self-collected at-home swabs had good performance acceptable for gonorrhea and chlamydia nucleic acid amplification testing.


Asunto(s)
Infecciones por Chlamydia , Chlamydia trachomatis , Gonorrea , Neisseria gonorrhoeae , Faringe , Recto , Manejo de Especímenes , Humanos , Chlamydia trachomatis/aislamiento & purificación , Chlamydia trachomatis/genética , Infecciones por Chlamydia/diagnóstico , Infecciones por Chlamydia/microbiología , Gonorrea/diagnóstico , Gonorrea/microbiología , Masculino , Neisseria gonorrhoeae/aislamiento & purificación , Neisseria gonorrhoeae/genética , Recto/microbiología , Faringe/microbiología , Manejo de Especímenes/métodos , Adulto , Femenino , Técnicas de Amplificación de Ácido Nucleico/métodos , Homosexualidad Masculina , Persona de Mediana Edad , Autocuidado , Adulto Joven
3.
Biochem Biophys Res Commun ; 715: 149994, 2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-38692139

RESUMEN

Many virus lysis/transport buffers used in molecular diagnostics, including the detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) RNA, contain guanidine-based chaotropic salts, primarily guanidine hydrochloride (GuHCl) or guanidine isothiocyanate (GITC). Although the virucidal effects of GuHCl and GITC alone against some enveloped viruses have been established, standardized data on their optimum virucidal concentrations against SARS-CoV-2 and effects on viral RNA stability are scarce. Thus, we aimed to determine the optimum virucidal concentrations of GuHCl and GITC against SARS-CoV-2 compared to influenza A virus (IAV), another enveloped respiratory virus. We also evaluated the effectiveness of viral RNA stabilization at the determined optimum virucidal concentrations under high-temperature conditions (35°C) using virus-specific real-time reverse transcription polymerase chain reaction. Both viruses were potently inactivated by 1.0 M GITC and 2.5 M GuHCl, but the GuHCl concentration for efficient SARS-CoV-2 inactivation was slightly higher than that for IAV inactivation. GITC showed better viral RNA stability than GuHCl at the optimum virucidal concentrations. An increased concentration of GuHCl or GITC increased viral RNA degradation at 35°C. Our findings highlight the need to standardize GuHCl and GITC concentrations in virus lysis/transport buffers and the potential application of these guanidine-based salts alone as virus inactivation solutions in SARS-CoV-2 and IAV molecular diagnostics.


Asunto(s)
Guanidina , Virus de la Influenza A , ARN Viral , SARS-CoV-2 , Manejo de Especímenes , SARS-CoV-2/efectos de los fármacos , SARS-CoV-2/genética , Virus de la Influenza A/efectos de los fármacos , Virus de la Influenza A/genética , Guanidina/farmacología , Guanidina/química , ARN Viral/genética , Humanos , Manejo de Especímenes/métodos , Genoma Viral , COVID-19/virología , COVID-19/diagnóstico , Chlorocebus aethiops , Células Vero , Inactivación de Virus/efectos de los fármacos , Animales , Estabilidad del ARN/efectos de los fármacos , Contención de Riesgos Biológicos , Guanidinas/farmacología , Guanidinas/química , Sales (Química)/farmacología , Sales (Química)/química
4.
Methods Mol Biol ; 2775: 47-55, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38758310

RESUMEN

In vivo models provide advantages to study the progression of disease and to identify potential biomarkers to detect and monitor infections. For the human fungal pathogen Cryptococcus neoformans, murine intranasal models aim to recapitulate natural infection from inhalation of desiccated fungal cells from the environment and permit monitoring of disease over time. In this chapter, we describe the establishment of a murine model for cryptococcosis and the subsequent collection of organs, tissues, and fluids for sampling. These samples may support novel diagnostic strategies and opportunities to monitor dissemination of the fungal cells throughout the host and propose new treatment options to combat disease.


Asunto(s)
Criptococosis , Cryptococcus neoformans , Modelos Animales de Enfermedad , Animales , Cryptococcus neoformans/patogenicidad , Criptococosis/microbiología , Criptococosis/diagnóstico , Ratones , Manejo de Especímenes/métodos , Humanos
5.
Methods Mol Biol ; 2775: 141-153, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38758316

RESUMEN

This chapter describes methodological details for preparing specimens of Cryptococcus neoformans (although it can be applied to any species of the genus) and their subsequent analysis by scanning and transmission electron microscopy. Adaptations to conventional protocols for better preservation of the sample, as well as to avoid artifacts, are presented. The protocols may be used to examine both the surface ultrastructure and the interior of this pathogenic fungus in detail.


Asunto(s)
Artefactos , Cryptococcus neoformans , Cryptococcus neoformans/ultraestructura , Microscopía Electrónica de Transmisión/métodos , Microscopía Electrónica de Rastreo/métodos , Manejo de Especímenes/métodos
6.
J Breath Res ; 18(3)2024 May 17.
Artículo en Inglés | MEDLINE | ID: mdl-38701772

RESUMEN

The analysis of volatile organic compounds (VOCs) in exhaled air has attracted the interest of the scientific community because it provides the possibility of monitoring physiological and metabolic processes and non-invasive diagnostics of various diseases. However, this method remains underused in clinical practice as well as in research because of the lack of standardized procedures for the collection, storage and transport of breath samples, which would guarantee good reproducibility and comparability of results. The method of sampling, as well as the storage time of the breath samples in the polymer bags used for sample storage and transport, affect the composition and concentration of VOCs present in the breath samples. The aim of our study was to compare breath samples obtained using two methods with fully disposable equipment: a Haldane sampling tube intended for direct breath collection and breath samples exhaled into a transparent Tedlar bag. The second task was to monitor the stability of selected compounds of real breath samples stored in a Tedlar bag for 6 h. Gas chromatography coupled with ion mobility spectrometry (GC-IMS) implemented in the BreathSpec®device was used to analyse exhaled breath. Our results showed a significant difference in the signal intensity of some volatiles when taking a breath sample with a Haldane tube and a Tedlar bag. Due to its endogenous origin, acetone levels were significantly higher when the Haldane tube sampler was used while elevated levels of 2-propanol and unidentified VOC (designated as VOC 3) in the Tedlar bag samples likely originated from contamination of the Tedlar bags. The VOC stability study revealed compound-specific signal intensity changes of the selected VOCs with storage time in the Tedlar bags, with some volatiles showing increasing signal intensity during storage in Tedlar bags. This limits the use of Tedlar bags only for very limited time and carefully selected purpose. Our results highlight the importance of careful design and implementation of experiments and clinical protocols to obtain relevant and reliable results.


Asunto(s)
Pruebas Respiratorias , Manejo de Especímenes , Compuestos Orgánicos Volátiles , Humanos , Pruebas Respiratorias/instrumentación , Pruebas Respiratorias/métodos , Compuestos Orgánicos Volátiles/análisis , Manejo de Especímenes/instrumentación , Manejo de Especímenes/métodos , Espectrometría de Movilidad Iónica/métodos , Espectrometría de Movilidad Iónica/instrumentación , Masculino , Femenino , Reproducibilidad de los Resultados , Adulto , Cromatografía de Gases y Espectrometría de Masas/métodos , Cromatografía de Gases y Espectrometría de Masas/instrumentación , Espiración , Persona de Mediana Edad , Factores de Tiempo
7.
Mol Neurodegener ; 19(1): 40, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750570

RESUMEN

Alzheimer's disease (AD), the most common form of dementia, remains challenging to understand and treat despite decades of research and clinical investigation. This might be partly due to a lack of widely available and cost-effective modalities for diagnosis and prognosis. Recently, the blood-based AD biomarker field has seen significant progress driven by technological advances, mainly improved analytical sensitivity and precision of the assays and measurement platforms. Several blood-based biomarkers have shown high potential for accurately detecting AD pathophysiology. As a result, there has been considerable interest in applying these biomarkers for diagnosis and prognosis, as surrogate metrics to investigate the impact of various covariates on AD pathophysiology and to accelerate AD therapeutic trials and monitor treatment effects. However, the lack of standardization of how blood samples and collected, processed, stored analyzed and reported can affect the reproducibility of these biomarker measurements, potentially hindering progress toward their widespread use in clinical and research settings. To help address these issues, we provide fundamental guidelines developed according to recent research findings on the impact of sample handling on blood biomarker measurements. These guidelines cover important considerations including study design, blood collection, blood processing, biobanking, biomarker measurement, and result reporting. Furthermore, the proposed guidelines include best practices for appropriate blood handling procedures for genetic and ribonucleic acid analyses. While we focus on the key blood-based AD biomarkers for the AT(N) criteria (e.g., amyloid-beta [Aß]40, Aß42, Aß42/40 ratio, total-tau, phosphorylated-tau, neurofilament light chain, brain-derived tau and glial fibrillary acidic protein), we anticipate that these guidelines will generally be applicable to other types of blood biomarkers. We also anticipate that these guidelines will assist investigators in planning and executing biomarker research, enabling harmonization of sample handling to improve comparability across studies.


Asunto(s)
Enfermedad de Alzheimer , Bancos de Muestras Biológicas , Biomarcadores , Humanos , Enfermedad de Alzheimer/sangre , Enfermedad de Alzheimer/diagnóstico , Biomarcadores/sangre , Bancos de Muestras Biológicas/normas , Proyectos de Investigación/normas , Péptidos beta-Amiloides/sangre , Manejo de Especímenes/normas , Manejo de Especímenes/métodos , Proteínas tau/sangre
8.
Sci Rep ; 14(1): 11340, 2024 05 17.
Artículo en Inglés | MEDLINE | ID: mdl-38760358

RESUMEN

Genetics studies are used by wildlife managers and researchers to gain inference into a population of a species of interest. To gain these insights, microsatellites have been the primary method; however, there currently is a shift from microsatellites to single nucleotide polymorphisms (SNPs). With the different DNA requirements between microsatellites and SNPs, an investigation into which samples can provide adequate DNA yield is warranted. Using samples that were collected from previous genetic projects from regions in the USA from 2014 to 2021, we investigated the DNA yield of eight sample categories to gain insights into which provided adequate DNA to be used in ddRADseq or already developed high- or medium-density SNP panels. We found seven sample categories that met the DNA requirements for use in all three panels, and one sample category that did not meet any of the three panels requirements; however, DNA integrity was highly variable and not all sample categories that met panel DNA requirements could be considered high quality DNA. Additionally, we used linear random-effects models to determine which covariates would have the greatest influence on DNA yield. We determined that all covariates (tissue type, storage method, preservative, DNA quality, time until DNA extraction and time after DNA extraction) could influence DNA yield.


Asunto(s)
ADN , Polimorfismo de Nucleótido Simple , ADN/genética , ADN/análisis , Animales , Repeticiones de Microsatélite/genética , Manejo de Especímenes/métodos
9.
PLoS One ; 19(5): e0303304, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38758919

RESUMEN

BACKGROUND AND OBJECTIVE: Collection of biosamples for translational research studies is vital for understanding biological pathways, discovering disease-related biomarkers, and identifying novel therapeutic targets. However, a lack of infrastructure for sample procurement, processing, storage, and shipping may hinder the ability of clinical research units to effectively engage in translational research. The purpose of this study was to identify the barriers to biosampling-based translational research in the critical care setting in Canada. METHODS: We administered an online survey to members of the Canadian Critical Care Trials Group (CCCTG), the Canadian Critical Care Translational Biology Group (CCCTBG), and the Canadian Critical Care Research Coordinators Group (CCCRCG). The survey focused on participants' personal experience of biosampling research, research infrastructure, motivating factors, and perceived barriers. RESULTS: We received 59 responses from 31 sites, including 6 community intensive care unit (ICU) sites. The overall response rate was 11.3%. The majority of respondents were research coordinators (44%), followed by clinician-investigators (33.8%), graduate students (10.2%), and PhD-investigators (8.5%). Although most (63.8%) respondents reported an interest in participating in translational research, they also reported that their ICUs were currently contributing to a third of the number of translational studies compared to clinical studies. For respondents with experience in participating in translational research studies, the most common barriers were lack of funding, lack of time, and insufficient research staff. For respondents without previous experience, the perceived facilitators were more interest from their research group, improved training/mentorship, increased funding, and better access to laboratory equipment. CONCLUSIONS: Our survey found that the majority of participants were interested in and recognize the value of participating in biosampling-based translational research but lacked funding, time, and research personnel trained in biosampling protocols. Our survey also identified factors that might encourage participation at new sites. Addressing these barriers will be a key step towards increasing translational research capacity across Canada.


Asunto(s)
Cuidados Críticos , Investigadores , Investigación Biomédica Traslacional , Humanos , Canadá , Estudios Transversales , Encuestas y Cuestionarios , Masculino , Femenino , Manejo de Especímenes/métodos
10.
Cancer Med ; 13(9): e7189, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38706442

RESUMEN

OBJECTIVES: Endoscopic ultrasound-guided tissue acquisition (EUS-TA) is used for pathological diagnosis and obtaining samples for molecular testing, facilitating the initiation of targeted therapies in patients with pancreatic cancer. However, samples obtained via EUS-TA are often insufficient, requiring more efforts to improve sampling adequacy for molecular testing. Therefore, this study investigated the use of oil blotting paper for formalin fixation of samples obtained via EUS-TA. METHODS: This prospective study enrolled 42 patients who underwent EUS-TA for pancreatic cancer between September 2020 and February 2022 at the Osaka International Cancer Institute. After a portion of each sample obtained via EUS-TA was separated for routine histological evaluation, the residual samples were divided into filter paper and oil blotting paper groups for analysis. Accordingly, filter paper and oil blotting paper were used for the formalin fixation process. The total tissue, nuclear, and cytoplasm areas of each sample were quantitatively evaluated using virtual slides, and the specimen volume and histological diagnosis of each sample were evaluated by an expert pathologist. RESULTS: All cases were cytologically diagnosed as adenocarcinoma. The area ratios of the total tissue, nuclear, and cytoplasmic portions were significantly larger in the oil blotting paper group than in the filter paper group. The frequency of cases with large amount of tumor cells was significantly higher in the oil blotting paper group (33.3%) than in the filter paper group (11.9%) (p = 0.035). CONCLUSIONS: Oil blotting paper can increase the sample volume obtained via EUS-TA on glass slides and improve sampling adequacy for molecular testing.


Asunto(s)
Formaldehído , Neoplasias Pancreáticas , Fijación del Tejido , Humanos , Neoplasias Pancreáticas/patología , Neoplasias Pancreáticas/diagnóstico por imagen , Estudios Prospectivos , Masculino , Femenino , Fijación del Tejido/métodos , Anciano , Persona de Mediana Edad , Endosonografía/métodos , Manejo de Especímenes/métodos , Adenocarcinoma/patología , Adenocarcinoma/diagnóstico por imagen , Anciano de 80 o más Años , Papel , Biopsia por Aspiración con Aguja Fina Guiada por Ultrasonido Endoscópico/métodos
11.
Curr Protoc ; 4(5): e1034, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38717581

RESUMEN

Scanning electron microscopy (SEM) remains distinct in its ability to allow topographical visualization of structures. Key elements to consider for successful examination of biological specimens include appropriate preparative and imaging techniques. Chemical processing induces structural artifacts during specimen preparation, and several factors need to be considered when selecting fixation protocols to reduce these effects while retaining structures of interest. Particular care for proper dehydration of specimens is essential to minimize shrinkage and is necessary for placement under the high-vacuum environment required for routine operation of standard SEMs. Choice of substrate for mounting and coating specimens can reduce artifacts known as charging, and a basic understanding of microscope settings can optimize parameters to achieve desired results. This article describes fundamental techniques and tips for routine specimen preparation for a variety of biological specimens, preservation of labile or fragile structures, immune-labeling strategies, and microscope imaging parameters for optimal examination by SEM. © 2024 The Authors. Current Protocols published by Wiley Periodicals LLC. Basic Protocol 1: Chemical preparative techniques for preservation of biological specimens for examination by SEM Alternate Protocol 1: Practical considerations for the preparation of soft tissues Alternate Protocol 2: Removal of debris from the exoskeleton of invertebrates Alternate Protocol 3: Fixation of colonies grown on agar plates Alternate Protocol 4: Stabilization of polysaccharide structures with alcian blue and lysine Alternate Protocol 5: Preparation of non-adherent particulates in solution for SEM Support Protocol 1: Application of thin layer of adhesive on substrate to improve adherence Support Protocol 2: Poly-L-lysine coating specimen substrates for improved adherence Support Protocol 3: Microwave processing of biological specimens for examination by SEM Basic Protocol 2: Critical point drying of specimens Alternate Protocol 6: Chemical alternative to critical point drying Basic Protocol 3: Sputter coating Alternate Protocol 7: Improved bulk conductivity through "OTOTO" Basic Protocol 4: Immune-labeling strategies Alternate Protocol 8: Immune-labeling internal antigens with small gold probes Alternate protocol 9: Quantum dot or fluoronanogold preparations for correlative techniques Basic Protocol 5: Exposure of internal structures by mechanical fracturing Basic Protocol 6: Exposure of internal structures of tissues by fracturing with liquid nitrogen Basic Protocol 7: Anaglyph production from stereo pairs to produce 3D images.


Asunto(s)
Microscopía Electrónica de Rastreo , Manejo de Especímenes , Microscopía Electrónica de Rastreo/métodos , Manejo de Especímenes/métodos , Animales
12.
Jt Dis Relat Surg ; 35(2): 299-304, 2024 Mar 21.
Artículo en Inglés | MEDLINE | ID: mdl-38727108

RESUMEN

OBJECTIVES: This study aimed to investigate whether adding tissue samples directly into thioglycolate (TG) broth yielded a greater number of anaerobic organisms than freshly sampled tissue in suspected hip and knee prosthetic joint infections (PJIs). PATIENTS AND METHODS: Between January 2017 and December 2020, a total of 90 patients (46 males, 44 females; median age: 71.7 years; range, 50.8 and 87.8 years) who underwent revision hip or knee arthroplasty were included. Intraoperative samples were taken, with five placed in TG broth and five in standard containers (PC) with subsequent aerobic and anaerobic culturing conducted. Demographic and baseline data of the patients were recorded. The primary outcome was positive bacterial growth from a PJI specimen inoculated directly into TG broth at the time of collection or standard PJI specimen processing. Secondary outcomes investigated were the presence of Cutibacterium acnes (C. acnes) and the curative success of revision procedure. RESULTS: A total of 900 samples (450 PC and 450 TG) were taken from 90 revision arthroplasty patients (47 knees and 43 hips). There was no statistically significant difference in the number of positive bacterial growth samples between TG broth and standard processing (p=0.742). This was consistent with subgroup analysis analyzing C. acnes (p=0.666). CONCLUSION: In hip and knee arthroplasty, there is no benefit in substituting or adding TG broth as a culture medium to better identify both general bacterial species and C. acnes infections specifically. However, the use of TG may be useful in confirming a true positive result for infection.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Artroplastia de Reemplazo de Rodilla , Infecciones Relacionadas con Prótesis , Tioglicolatos , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/microbiología , Infecciones Relacionadas con Prótesis/tratamiento farmacológico , Femenino , Masculino , Anciano , Persona de Mediana Edad , Anciano de 80 o más Años , Artroplastia de Reemplazo de Rodilla/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos , Tioglicolatos/farmacología , Prótesis de la Rodilla/efectos adversos , Prótesis de la Rodilla/microbiología , Medios de Cultivo/química , Medios de Cultivo/farmacología , Reoperación , Prótesis de Cadera/efectos adversos , Prótesis de Cadera/microbiología , Manejo de Especímenes/métodos , Estudios Retrospectivos
13.
Sci Rep ; 14(1): 10226, 2024 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-38702379

RESUMEN

Tracheal pooling for Mycoplasma hyopneumoniae (M. hyopneumoniae) DNA detection allows for decreased diagnostic cost, one of the main constraints in surveillance programs. The objectives of this study were to estimate the sensitivity of pooled-sample testing for the detection of M. hyopneumoniae in tracheal samples and to develop probability of M. hyopneumoniae detection estimates for tracheal samples pooled by 3, 5, and 10. A total of 48 M. hyopneumoniae PCR-positive field samples were pooled 3-, 5-, and 10-times using field M. hyopneumoniae DNA-negative samples and tested in triplicate. The sensitivity was estimated at 0.96 (95% credible interval [Cred. Int.]: 0.93, 0.98) for pools of 3, 0.95 (95% Cred. Int: 0.92, 0.98) for pools of 5, and 0.93 (95% Cred. Int.: 0.89, 0.96) for pools of 10. All pool sizes resulted in PCR-positive if the individual tracheal sample Ct value was < 33. Additionally, there was no significant decrease in the probability of detecting at least one M. hyopneumoniae-infected pig given any pool size (3, 5, or 10) of tracheal swabs. Furthermore, this manuscript applies the probability of detection estimates to various real-life diagnostic testing scenarios. Combining increased total animals sampled with pooling can be a cost-effective tool to maximize the performance of M. hyopneumoniae surveillance programs.


Asunto(s)
Mycoplasma hyopneumoniae , Neumonía Porcina por Mycoplasma , Tráquea , Mycoplasma hyopneumoniae/aislamiento & purificación , Mycoplasma hyopneumoniae/genética , Animales , Tráquea/microbiología , Porcinos , Neumonía Porcina por Mycoplasma/diagnóstico , Neumonía Porcina por Mycoplasma/microbiología , Reacción en Cadena de la Polimerasa/métodos , ADN Bacteriano/análisis , Sensibilidad y Especificidad , Manejo de Especímenes/métodos , Probabilidad
14.
Sci Rep ; 14(1): 10496, 2024 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714714

RESUMEN

The use of self-collected specimens as an alternative to healthcare worker-collected specimens for diagnostic testing has gained increasing attention in recent years. This systematic review aimed to assess the diagnostic accuracy of self-collected specimens compared to healthcare worker-collected specimens across different sexually transmitted infections (STIs) including Chlamydia trachomatis (CT), human papillomavirus (HPV), Mycoplasma genitalium (MG), Neisseria gonorrhoea (NG), Treponema pallidum and Trichomonas vaginalis (TV) in females. A rigorous process was followed to screen for studies in various electronic databases. The quality of included studies was assessed using the Quality Assessment of Diagnostic Accuracy Studies 2 tool. There were no studies on syphilis that met the criteria for inclusion in the review. A total of six studies for chlamydia, five studies for HPV, four studies for MG, and seven studies for gonorrhoea and trichomoniasis were included in the review. However, not all studies were included in the sub-group meta-analysis. The analysis revealed that self-collected specimens demonstrated comparable diagnostic accuracy to healthcare worker-collected specimens across most STIs. This indicates that the diagnostic accuracy of self-collected specimens can provide accurate results and enhance access to diagnostic testing, potentially improving healthcare service delivery. Future research should further explore the diagnostic accuracy of self-collected specimens in larger and more diverse populations.


Asunto(s)
Personal de Salud , Enfermedades de Transmisión Sexual , Manejo de Especímenes , Humanos , Femenino , Enfermedades de Transmisión Sexual/diagnóstico , Enfermedades de Transmisión Sexual/microbiología , Manejo de Especímenes/métodos , Neisseria gonorrhoeae/aislamiento & purificación , Gonorrea/diagnóstico , Chlamydia trachomatis/aislamiento & purificación
15.
Sci Rep ; 14(1): 10923, 2024 05 13.
Artículo en Inglés | MEDLINE | ID: mdl-38740976

RESUMEN

Though pooling samples for SARS-CoV-2 detection has effectively met the need for rapid diagnostic and screening tests, many factors can influence the sensitivity of a pooled test. In this study, we conducted a simulation experiment to evaluate modes of pooling specimens and aimed at formulating an optimal pooling strategy. We focussed on the type of swab, their solvent adsorption ability, pool size, pooling volume, and different factors affecting the quality of preserving RNA by different virus solutions. Both quantitative PCR and digital PCR were used to evaluate the sampling performance. In addition, we determined the detection limit by sampling which is simulated from the virus of different titers and evaluated the effect of sample-storage conditions by determining the viral load after storage. We found that flocked swabs were better than fibre swabs. The RNA-preserving ability of the non-inactivating virus solution was slightly better than that of the inactivating virus solution. The optimal pooling strategy was a pool size of 10 samples in a total volume of 9 mL. Storing the collected samples at 4 °C or 25 °C for up to 48 h had little effect on the detection sensitivity. Further, we observed that our optimal pooling strategy performed equally well as the single-tube test did. In clinical applications, we recommend adopting this pooling strategy for low-risk populations to improve screening efficiency and shape future strategies for detecting and managing other respiratory pathogens, thus contributing to preparedness for future public health challenges.


Asunto(s)
COVID-19 , ARN Viral , SARS-CoV-2 , Manejo de Especímenes , Humanos , COVID-19/diagnóstico , COVID-19/virología , SARS-CoV-2/aislamiento & purificación , SARS-CoV-2/genética , Manejo de Especímenes/métodos , ARN Viral/genética , Prueba de Ácido Nucleico para COVID-19/métodos , Carga Viral/métodos , Reacción en Cadena en Tiempo Real de la Polimerasa/métodos , Sensibilidad y Especificidad , Prueba de COVID-19/métodos
16.
Curr Opin Obstet Gynecol ; 36(3): 113-117, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38597803

RESUMEN

PURPOSE OF REVIEW: Semen analysis is a basic component of male evaluation. Reproductive centers typically instruct men to provide a semen specimen based on recommendations from WHO Standard for semen examination. Evidence that these recommendations optimize sperm reproductive capacity is lacking. Existing data to optimize sperm quality with shorter abstinence were reviewed. RECENT FINDINGS: Several recent studies have reviewed the effects of shorter ejaculatory abstinence of semen quality and assisted reproductive technology (ART) outcomes. Shorter abstinence was defined as 1 h-1 day in one review, and <4 h in the other systematic meta-analysis and review. SUMMARY: Prior instructions for male patients have not been designed to optimize fertility potential for semen analyses. Optimal sperm quality is obtained by instructing men to have a short abstinence (certainly <1 day, and preferably <4 h) for semen specimens used for in vitro fertilization (assisted reproduction).


Asunto(s)
Técnicas Reproductivas Asistidas , Análisis de Semen , Abstinencia Sexual , Humanos , Masculino , Manejo de Especímenes/métodos , Factores de Tiempo , Femenino , Embarazo , Eyaculación/fisiología , Espermatozoides/fisiología , Fertilización In Vitro/métodos
17.
Clin Biochem ; 127-128: 110763, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38615787

RESUMEN

OBJECTIVES: Contamination with intravenous (IV) fluids is a common cause of specimen rejection or erroneous results in hospitalized patients. Identification of contaminated samples can be difficult. Common measures such as failed delta checks may not be adequately sensitive nor specific. This study aimed to determine detection criteria using commonly ordered tests to identify IV fluid contamination and validate the use of these criteria. METHODS: Confirmed contaminated and non-contaminated samples were used to identify patterns in laboratory results to develop criteria to detect IV fluid contamination. The proposed criteria were implemented at a tertiary care hospital laboratory to assess performance prospectively for 6 months, and applied to retrospective chemistry results from 3 hospitals and 1 community lab to determine feasibility and flagging rates. The algorithm was also tested at an external institution for transferability. RESULTS: The proposed algorithm had a positive predictive value of 92 %, negative predictive value of 91 % and overall agreement of 92 % when two or more criteria are met (n = 214). The flagging rates were 0.03 % to 0.07 % for hospital and 0.003 % for community laboratories. CONCLUSIONS: The proposed algorithm identified true contamination with low false flagging rates in tertiary care urban hospital laboratories. Retrospective and prospective analysis suggest the algorithm is suitable for implementation in clinical laboratories to identify samples with possible IV fluid contamination for further investigation.


Asunto(s)
Algoritmos , Humanos , Estudios Retrospectivos , Laboratorios Clínicos , Estudios Prospectivos , Manejo de Especímenes/métodos , Manejo de Especímenes/normas
18.
J Microbiol Methods ; 221: 106939, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38653334

RESUMEN

BACKGROUND: Fecal samples are commonly used for longitudinal studies of the gut lumen microbiome to track the course of response to infection or drug treatment, but no comparable method has been evaluated for longitudinal analysis of the gastric lumen microbiome in mice. Herein, a buffer flush of the stomach with a flexible gavage needle was used to collect gastric contents at one or several time points without harming the mouse. These samples were compared to samples collected by sacrifice and dissection of the mouse stomach. Microbiota from these samples were sequenced and evaluated in two ways: the composition of samples as measured by beta diversity and the richness of samples as measured by alpha diversity. Additionally, the effect of multiple sampling every two days on these metrics were studied. DNA was extracted from each of these samples and Illumina 16S rRNA gene sequencing was performed. RESULTS: First, taxonomic richness of gavage and dissection samples was compared. A greater number of taxa was detected in gavage samples than in dissection samples. Second, taxonomic richness was analyzed over time. No significant difference in taxonomic richness was observed with repeated gavage flushes. Third, a comparison was made of the taxonomic composition of samples collected by gavage versus dissection followed by a comparison of samples collected over multiple samplings. Nonmetric multidimensional scaling analysis revealed no clear differences between collection by gavage flushing or dissection. Using weighted Unifrac and Aitchison taxonomic distances between gavage and dissection samples were not significantly different from distances between gavage samples themselves, and no significant difference was found in the taxonomic composition of mice which were sampled repeatedly. Finally, relative abundances of specific identified taxa were compared, and eleven taxa were found to differ in frequency between collection methods. Using the more stringent Analysis of Composition of Microbiomes (ANCOM), seven was found to differ. Similarly, no significant differences were uncovered using these analyses over multiple samples by gastric flush. CONCLUSION: In summary, the consistency of the microbiota collected by gastric flushing recommends its use for microbiome analysis of gastric fluid similar to the use of fecal sampling to study the gut lumen microbiome.


Asunto(s)
Microbioma Gastrointestinal , ARN Ribosómico 16S , Manejo de Especímenes , Estómago , Animales , Ratones , ARN Ribosómico 16S/genética , Microbioma Gastrointestinal/genética , Manejo de Especímenes/métodos , Estómago/microbiología , Bacterias/clasificación , Bacterias/genética , Bacterias/aislamiento & purificación , Estudios Longitudinales , Heces/microbiología , ADN Bacteriano/genética , Análisis de Secuencia de ADN/métodos , Biodiversidad , Ratones Endogámicos C57BL
19.
Curr Opin Struct Biol ; 86: 102823, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38688075

RESUMEN

Specimen preparation is a critical but challenging step in high-resolution cryogenic electron microscopy (cryo-EM) structural analysis of macromolecules. In the past decade, graphene has gained much recognition as the supporting substrate to optimize cryo-EM specimen preparation. It improves macromolecule embedding in ice, reduces beam-induced motion, while imposing negligible background noise. Various types of graphene-coated cryo-EM grids were implemented to improve the robustness and efficiency of specimen preparation. Graphene functionalization by different means has been proved specifically useful in addressing challenges related to the air-water interface (AWI), such as preferential orientation and sample denaturation. Graphene sandwich specimen preparation sets a new direction to explore in cryo-EM analysis of biological specimens. In this review, we discuss the current challenges and future prospects of graphene application in cryo-EM analysis of macromolecules.


Asunto(s)
Microscopía por Crioelectrón , Grafito , Microscopía por Crioelectrón/métodos , Grafito/química , Sustancias Macromoleculares/química , Manejo de Especímenes/métodos
20.
BMC Public Health ; 24(1): 1104, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649876

RESUMEN

BACKGROUND: This study aimed to assess the acceptability and attitudes of women towards human papillomavirus (HPV) self-sampling and compare the effectiveness of two delivery modes utilising face-to-face and online website for cervical cancer screening in Hong Kong. METHODS: Women aged 30-65 years were invited to participate by distributing the study information pamphlets at the specialist clinics of a regional acute hospital. Those who were interested in participating were given the option to join directly face-to-face or through an online website. All participants provided informed consent and received self-sampling kits and acceptability questionnaires either immediately (face-to-face) or through the post after registering at the website (online). All participants were requested to collect their own vaginal samples using a swab which was then brushed on a DNA sample storage card and returned to the hospital either in person or by post. The self-collected samples were tested for high-risk HPV using the Sentis™ HPV assay, a validated isothermal nucleic acid amplification real-time fluorescent detection assay. The primary outcome was the uptake rate of HPV self-sampling. RESULTS: Of the 1998 women recruited (1200 face-to-face, 798 online), 1377 returned their samples, giving an overall uptake rate of 68.9%. The uptake rate was significantly greater in the face-to-face mode than in the online mode (74.6% vs. 60.4%, p < 0.001). The median age of the participants was 49 years, 43.7% were never or under-screened, and 7.1% had high-risk HPV detected. Overall, 82.1% of the participants reported self-sampling convenient, and 79.3% were not embarrassed when collecting self-samples. However, only 49.8% were confident that they had collected the self-samples correctly. Most (91.1%) of the participants expressed willingness to perform self-sampling again, mostly because it was simple (79.2%) and quick (56.3%). CONCLUSIONS: HPV self-sampling can serve as an alternative primary screening method for cervical cancer in Hong Kong, especially for individuals who have not been adequately screened in the past. Both face-to-face and online website recruitment were associated with high acceptability, emphasising the potential benefits of utilising different platforms and strategies for reaching diverse populations.


Asunto(s)
Detección Precoz del Cáncer , Aceptación de la Atención de Salud , Manejo de Especímenes , Neoplasias del Cuello Uterino , Humanos , Femenino , Persona de Mediana Edad , Adulto , Neoplasias del Cuello Uterino/diagnóstico , Hong Kong , Anciano , Detección Precoz del Cáncer/métodos , Manejo de Especímenes/métodos , Aceptación de la Atención de Salud/estadística & datos numéricos , Infecciones por Papillomavirus/diagnóstico , Autocuidado , Internet , Frotis Vaginal/métodos , Papillomaviridae/aislamiento & purificación , Encuestas y Cuestionarios , Virus del Papiloma Humano
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA