Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 482
Filtrar
1.
BMC Oral Health ; 24(1): 1023, 2024 Aug 30.
Artículo en Inglés | MEDLINE | ID: mdl-39215266

RESUMEN

BACKGROUND: Calcium silicate-based bioceramics have been applied in endodontics as advantageous materials for years, many chemical components and new synthesizing methods were used to improve the base formulation of the materials for positively affecting the sealers properties. Recently, a novel biomaterial formulation, grounded in strontium silicate, has been introduced to the market, offering potential advancements in the field. OBJECTIVE: To comparatively analyze the cytotoxicity and cell migration effects of a novel strontium silicate-based bioceramic material (CRoot SP) and those of calcium silicate-based (iRoot SP) and epoxide amine resin (AH Plus) sealers on stem cells derived from rat apical papilla(rSCAPs). METHODS: rSCAPs were isolated and characterized in vitro and subsequently cultured in the presence of various concentrations of CRoot SP, iRoot SP and AH Plus extracts. Cytotoxicity was assessed by CCK-8 assay, and cell-migration capacity was assessed by using wound healing assays . RESULTS: No significant differences in cell viability were observed in the 0.02 mg/mL and 0.2 mg/mL sealer groups. The cell viability of CRoot SP was consistently greater than that of iRoot SP at concentrations of 5 mg/mL and 10 mg/mL across all time points. Maximum cytotoxic effect was noted on day 5 with 10 mg/mL AH Plus.The scratch was partly healed by cell migration in all groups at 24 h, and the 0.02 mg/mL, and 0.2 mg/mL CRoot SP exerted beneficial effects on rSCAPs migration. CONCLUSIONS: CRoot SP exhibited less cytotoxic than the iRoot SP and AH Plus extracts after setting. A lower concentration of CRoot SP thus promotes the cell migration capacity of rSCAPs, and it may achieve better tissue repair during root canal treatment.


Asunto(s)
Compuestos de Calcio , Movimiento Celular , Supervivencia Celular , Resinas Epoxi , Materiales de Obturación del Conducto Radicular , Silicatos , Células Madre , Animales , Silicatos/farmacología , Movimiento Celular/efectos de los fármacos , Materiales de Obturación del Conducto Radicular/farmacología , Materiales de Obturación del Conducto Radicular/toxicidad , Ratas , Compuestos de Calcio/farmacología , Resinas Epoxi/farmacología , Resinas Epoxi/toxicidad , Supervivencia Celular/efectos de los fármacos , Células Madre/efectos de los fármacos , Técnicas In Vitro , Ensayo de Materiales , Células Cultivadas , Cerámica/farmacología , Estroncio/farmacología , Papila Dental/citología , Papila Dental/efectos de los fármacos , Ápice del Diente/efectos de los fármacos , Ápice del Diente/citología
2.
Int Endod J ; 57(9): 1293-1314, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38804676

RESUMEN

AIM: The present study examined the leaching and cytotoxicity of bismuth from ProRoot MTA and aimed to identify whether bismuth leaching was affected by the cement base and the immersion regime used. METHODOLOGY: The leaching profile of bismuth was examined from ProRoot MTA and compared with hydroxyapatite containing 20% bismuth oxide as well as hydroxyapatite and tricalcium silicate to investigate whether bismuth release changed depending on the cement base. Bismuth leaching was determined after 30 and 180 days of ageing immersed in Dulbecco's modified Eagle's medium (DMEM) using mass spectroscopy (ICP-MS). The media were either unchanged or regularly replenished. The pH, surface microstructure and phase changes of aged materials were assessed. Wistar rat femoral bone marrow stromal cells (BMSCs) and cutaneous fibroblasts were isolated, cultured and seeded for cell counting (trypan blue live/dead) after exposure to non-aged, 30- and 180-days-aged samples in regularly replenished DMEM. Aged DMEM in contact with materials was also used to culture BMSCs to investigate the effect of material leachates on the cells. Gene expression analysis was also carried out after direct exposure of cells to non-aged materials. Differences between groups were statistically tested at a significance level of 5%. RESULTS: All materials exhibited alterations after immersion in DMEM and this increased with longer exposure times. The bismuth leached from ProRoot MTA as detected by ICP-MS. Aged ProRoot MTA samples exhibited a black discolouration and surface calcium carbonate deposition. ProRoot MTA influenced cell counts after direct exposure and its 180-days leachates reduced BMSC viability. After direct BMSC contact with non-aged ProRoot MTA an upregulation of metallothionein (MT1 and MT2A) expression and down-regulation of collagen-1a (Col-1a) and bone sialoprotein (BSP) expression was identified. CONCLUSIONS: Bismuth leaching was observed throughout 180-days observation period from all materials containing bismuth oxide. This negatively influenced cell viability and gene expression associated with bismuth exposure. This is the first study to report that metallothionein gene expression was influenced by exposure to ProRoot MTA.


Asunto(s)
Bismuto , Compuestos de Calcio , Combinación de Medicamentos , Óxidos , Ratas Wistar , Materiales de Obturación del Conducto Radicular , Silicatos , Bismuto/toxicidad , Animales , Silicatos/toxicidad , Compuestos de Calcio/toxicidad , Compuestos de Calcio/farmacología , Compuestos de Calcio/química , Ratas , Óxidos/toxicidad , Materiales de Obturación del Conducto Radicular/toxicidad , Ensayo de Materiales , Fibroblastos/efectos de los fármacos , Compuestos de Aluminio/toxicidad , Células Cultivadas , Durapatita , Células Madre Mesenquimatosas/efectos de los fármacos
3.
Odontology ; 112(4): 1178-1185, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-38493437

RESUMEN

The aim of this work was to evaluate the toxicological action of AH Plus (AHP), Bio-C Sealer (BCS), and EndoSequence BC Sealer (ESB), using Drosophila melanogaster as the model organism performing in vivo and ex vivo analysis. D. melanogaster were exposed for 10 days to three concentrations (5 mg/ml, 10 mg/ml, and 20 mg/ml) of AHP, BCS, and ESB sealers mixed with 10 ml of standard diet. During this period, the mortality of flies was evaluated. On the 11th day, the locomotor activity test was performed and the flies were euthanized for oxidative damage analysis (reactive species and lipid peroxidation) and cell viability (resazurin reduction). For the mortality curves evaluation, the log-rank test (Mantel-Cox) was used. For the analysis of other data, a one-way analysis of variance (ANOVA) was applied, followed by Tukey's post hoc test (α = 0.05). Regarding mortality, there were no significant differences. The locomotor activity was reduced, mainly in the two highest concentrations of AHP and BCS. Besides, reactive species generation was bigger in the AHP 20 mg/ml group. AHP induced a lipid peroxidation increase in all three concentrations tested, when compared to other sealers. Considering cell viability, the two highest concentrations of AHP reduced this parameter; while in other sealers, viability was reduced only in the highest concentration. AHP showed changes in oxidative markers that led to greater damage to the flies.


Asunto(s)
Supervivencia Celular , Drosophila melanogaster , Peroxidación de Lípido , Estrés Oxidativo , Materiales de Obturación del Conducto Radicular , Animales , Drosophila melanogaster/efectos de los fármacos , Supervivencia Celular/efectos de los fármacos , Estrés Oxidativo/efectos de los fármacos , Materiales de Obturación del Conducto Radicular/toxicidad , Peroxidación de Lípido/efectos de los fármacos , Especies Reactivas de Oxígeno/metabolismo , Resinas Epoxi/toxicidad , Ensayo de Materiales
4.
BMC Oral Health ; 24(1): 262, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38389110

RESUMEN

BACKGROUND: The objective of the present study was to evaluate in vitro the cytotoxicity and bioactivity of various endodontic sealers (CeraSeal, BioRoot™ and AH Plus®) in pre-osteoblast mouse cells (MC3T3 cells). METHODS: MC3T3 cells (ATCC CRL-2594) were plated in 1 × 104 cells/well in 96-well plates in contact with endodontic sealers at concentrations of 1:10 and 1:100. Cell viability was evaluated by MTT assay after 24 and 48 h. In addition, sealer bioactivity was measured by RT-PCR for mediator of inflammation (Tnf, Ptgs2) and mineralization (Runx2, Msx1, Ssp1 and Dmp1) after 24 h and by Alizarin Red S Assay of mineralization after 28 days. Data were analyzed using one-way ANOVA followed by the Tukey's post-test at a significance level of 5%. RESULTS: BioRoot™ presented 24-hour cytotoxicity (p < 0.05) at 1:10 concentration. In the period of 48 h, no endodontic cement was cytotoxic to the cells compared to the control (p > 0.05). TNF-α gene expression was induced by AH Plus® (p < 0.05), while Ptgs2 was induced by the CeraSeal and BioRoot™ (p < 0.05). The expression of Runx2 was stimulated by BioRoot™ and AH Plus® (p < 0.05). In contrast, the expression of Dmp-1 Dmp1 was higher for the CeraSeal and BioRoot™ (p < 0.05). Nonetheless, the sealers did not impact the formation of mineralization nodules (p > 0.05). CONCLUSION: CeraSeal, BioRoot™ and AH Plus® sealers were not cytotoxic to MC3T3 cells within 48 h, but differentially induced the expression of genes related to inflammation and mineralization without impacting biomineralization by the cells.


Asunto(s)
Subunidad alfa 1 del Factor de Unión al Sitio Principal , Materiales de Obturación del Conducto Radicular , Ratones , Animales , Ensayo de Materiales , Ciclooxigenasa 2 , Materiales de Obturación del Conducto Radicular/toxicidad , Resinas Epoxi , Osteoblastos , Inflamación
5.
Clin Oral Investig ; 28(2): 148, 2024 Feb 14.
Artículo en Inglés | MEDLINE | ID: mdl-38353803

RESUMEN

OBJECTIVES: The present study aimed to determine in silico toxicity predictions of test compounds from hydraulic calcium silicate-based sealers (HCSBS) and AH Plus and computationally simulate the interaction between these substances and mediators of periapical inflammation via molecular docking. MATERIALS AND METHODS: All chemical information of the test compounds was obtained from the PubChem site. Predictions for bioavailability and toxicity analyses were determined by the Molinspiration Cheminformatics, pkCSM, ProTox-II and OSIRIS Property Explorer platforms. Molecular docking was performed using the Autodock4 AMDock v.1.5.2 program to analyse interactions between proteins (IL-1ß, IL-6, IL-8, IL-10 and TNF-α) and ligands (calcium silicate hydrate, zirconium oxide, bisphenol-A epoxy resin, dibenzylamine, iron oxide and calcium tungstate) to establish the affinity and bonding mode between systems. RESULTS: Bisphenol-A epoxy resin had the lowest maximum dose tolerated in humans and was the test compound with the largest number of toxicological properties (hepatotoxicity, carcinogenicity and irritant). All systems had favourable molecular docking. However, the ligands bisphenol-A epoxy resin and dibenzylamine had the greatest affinity with the cytokines tested. CONCLUSION: In silico predictions and molecular docking pointed the higher toxicity and greater interaction with mediators of periapical inflammation of the main test compounds from AH Plus compared to those from HCSBS. CLINICAL RELEVANCE: This is the first in silico study involving endodontic materials and may serve as the basis for further research that can generate more data, producing knowledge on the interference of each chemical compound in the composition of different root canal sealers.


Asunto(s)
Compuestos de Bencidrilo , Bencilaminas , Compuestos de Calcio , Resinas Epoxi , Fenoles , Materiales de Obturación del Conducto Radicular , Silicatos , Humanos , Resinas Epoxi/toxicidad , Simulación del Acoplamiento Molecular , Inflamación , Materiales de Obturación del Conducto Radicular/toxicidad
6.
Sci Rep ; 14(1): 4124, 2024 02 19.
Artículo en Inglés | MEDLINE | ID: mdl-38374199

RESUMEN

The aim of this study was to evaluate cytotoxicity and genotoxicity of calcium-silicate based sealers and comparing them with a gold standard-an epoxy-based sealant. Two experimental cell lines were used, gingival fibroblasts (hGF) and monocyte/macrophage peripheral blood cell line (SC). The cytotoxicity (XTT assay) and genotoxicity (comet assay) were evaluated both after 24-h and 48-h incubation. Additionally, after 48-h incubation, the cell apoptosis and cell cycle progression was detected. BioRoot Flow induced a significant decrease in hGF cells viability compared to the negative control groups both after 24-h (p < 0.001) and 48-h incubation (p < 0.01). In group with SC cells, after 24-h incubation significant increase in cells viability was detected for AH Plus Bioceramic Sealer in comparison to negative control (p < 0.05). BioRoot Flow and BioRoot RCS can be considered potentially genotoxic for the hGF cells after 48-h incubation (> 20% DNA damage). BioRoot Flow and BioRoot RCS, may have potential genotoxic effects and induce apoptosis in hGF cells which may irritate periapical tissues, resulting in a delayed healing. The findings of the study would be useful in selection of an appropriate sealant for root canal filling without causing cytotoxicity and genotoxicity.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/toxicidad , Cavidad Pulpar , Resinas Epoxi/toxicidad , Compuestos de Calcio , Línea Celular , Daño del ADN , Resinas de Plantas , Silicatos/toxicidad , Ensayo de Materiales
7.
Dent Mater J ; 42(6): 774-779, 2023 Nov 29.
Artículo en Inglés | MEDLINE | ID: mdl-37793827

RESUMEN

This study aimed to evaluate the cytotoxicity and genotoxicity of five endodontic sealers (AH Plus, MTA Fillapex, Endoseal MTA, Sealapex, and Zinc oxide eugenol) in Chinese hamster ovary cells. Cytotoxicity was evaluated by 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyl tetrazolium bromide (MTT) assay to check cell viability at 1, 3, and 7 days. Genotoxicity was assessed by cytokinesis-block micronucleus, single-cell gel electrophoresis, and γH2AX immunofluorescence assays. Cell viability of all endodontic sealers, except Endoseal MTA, on day 1 was less than 100%. Endoseal MTA showed the highest cell viability on day 7. AH Plus and Endoseal MTA showed less DNA damage than other sealers. After complete setting, AH Plus and Endoseal MTA showed low genotoxicity, which could reduce DNA damage in periapical cells, making them suitable as endodontic sealers.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Cricetinae , Animales , Materiales de Obturación del Conducto Radicular/toxicidad , Resinas Epoxi , Cricetulus , Células CHO , Ensayo de Materiales , Compuestos de Calcio , Silicatos
8.
Aust Endod J ; 49(3): 554-562, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37537929

RESUMEN

The purpose of this study was to assess the effect of a calcium silicate-based sealers (CeraSeal) and an epoxy resin-based sealer (AH Plus) on cytotoxicity and cell migration of stem cell from the human apical papilla (hSCAPs) by using the Alamar Blue, Annexin V-FICT and wound healing assays. In Alamar Blue assay, hSCAPs exposed to undiluted CeraSeal extract had significantly higher cell viability compared with that observed when cells were treated with AH Plus in all experimental period (p < 0.001). The flow cytometry analysis confirmed the comparison on viable cells and indicated that AH Plus increased apoptosis compared to CeraSeal and the control groups (p < 0.001). Additionally, AH Plus exhibited significantly lower level of cell migration than CeraSeal and the control for up to 48 h observation (p < 0.01). In summary, calcium silicate-based sealer (CeraSeal) is less cytotoxic and more biocompatible than epoxy resin-based sealer (AH Plus).


Asunto(s)
Resinas Epoxi , Materiales de Obturación del Conducto Radicular , Humanos , Resinas Epoxi/toxicidad , Materiales de Obturación del Conducto Radicular/toxicidad , Cavidad Pulpar , Ensayo de Materiales , Compuestos de Calcio/toxicidad , Silicatos/toxicidad , Células Madre , Movimiento Celular
9.
Clin Oral Investig ; 27(9): 5413-5425, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37486382

RESUMEN

OBJECTIVE: The aim of this study was to investigate solubility, pH value, chemical structure, radiopacity, and cytotoxicity of AH Plus BC, TotalFill BC, AH Plus, and AH Plus Jet sealers. MATERIALS AND METHODS: Cytotoxicity analysis with direct and extraction tests at 3 different concentrations (1:1, 1:2, 1:4 v/v%) and time (24 h, 48 h, and 72 h) on Saos-2, PdLF, and THP-1 cell lines, chemical structure with scanning electron microscopy (SEM) and energy-dispersive X-ray spectroscopy (EDX) analysis, solubility, pH, and radiopacity values of AH Plus BC, TotalFill BC, AH Plus, and AH Plus Jet were evaluated. For statistical analyses of the groups, repeated measures, factorial, and one-way ANOVA tests were used. The statistical significance level was set at p < .05. RESULTS: Resin-based sealers showed higher cytotoxicity values than the bioceramic-based sealers (p < 0.05). Time and concentrations were effective on the cell viabilities for cell lines. Higher peaks of calcium were detected bioceramic-based sealers and higher amount of zirconium was detected in AH Plus BC (p < 0.05). AH Plus BC showed similar radiopacity value with AH Plus, AH Plus Jet, whereas TotalFill BC showed the lowest radiopacity (p < 0.05). Bioceramic-based sealers had higher pH values in all experiment periods, and the difference between resin- and bioceramic-based sealer groups was significant (p < 0.05). However, the solubility values of the tested root canal sealers revealed no differences (p > 0.05). CONCLUSIONS: The newly produced AH Plus BC Sealer showed similar properties with TotalFill BC, and their biological properties were better than AH Plus and AH Plus Jet. CLINICAL RELEVANCE: AH Plus BC could be a possible alternative to other bioceramic- or resin-based sealers.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/toxicidad , Materiales de Obturación del Conducto Radicular/química , Resinas Epoxi/toxicidad , Resinas Epoxi/química , Solubilidad , Compuestos de Calcio/química , Cavidad Pulpar , Silicatos/química , Ensayo de Materiales , Concentración de Iones de Hidrógeno
10.
Int Endod J ; 56(8): 955-967, 2023 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-37165944

RESUMEN

AIM: This study aimed to evaluate the cytotoxicity, biocompatibility and osteoinductive profile of a mineral trioxide aggregate (MTA)-hydrogel-based material (MTA Flow) in comparison with MTA Angelus. METHODOLOGY: Cell viability was evaluated in human periodontal ligament stem cells (hPDLSCs) using the methyl-thiazol-tetrazolium (MTT) colourimetric assay. Polyethylene tubes containing the tested materials and empty polyethylene tubes (control) were implanted in the subcutaneous tissue of Wistar rats. Cellular (lymphocyte infiltration) and extracellular events (ECM; collagen fibres) were analysed in histological sections. Immunohistochemical (collagen I, osteopontin, bone sialoprotein, bone morphogenetic protein4) analyses were also performed. RESULTS: At 24, 48 and 72 h, all tested groups showed cell viability similar to control (p > .05). Regarding biocompatibility, all groups showed similar cellular events represented by a slight inflammatory reaction characterized by hyperaemia and a mild lymphocytic inflammatory infiltrate. The analysis of lymphocytes during the time showed a decrease in these cells in the control group and a significant interaction between MTA Angelus and control (p < .001), with MTA Angelus showing a more extensive inflammatory infiltrate. Regarding fibres, an increase in content was observed in all groups during the experimental time (7, 30 and 60 days), however, no difference was detected among the experimental groups (p = .063). After 60 days, the immunoexpression of bone matrix proteins in the MTA Flow group was similar to or higher than that observed in the MTA Angelus and in the control group. CONCLUSIONS: MTA Flow showed a non-cytotoxic behaviour, biocompatibility and ability to stimulate tissue mineralization.


Asunto(s)
Materiales Biocompatibles , Materiales de Obturación del Conducto Radicular , Ratas , Animales , Humanos , Ratas Wistar , Materiales Biocompatibles/farmacología , Compuestos de Calcio/farmacología , Hidrogeles , Óxidos/farmacología , Silicatos/toxicidad , Cementos Dentales , Cementos de Ionómero Vítreo , Colágeno , Polietilenos , Combinación de Medicamentos , Compuestos de Aluminio/toxicidad , Materiales de Obturación del Conducto Radicular/toxicidad , Ensayo de Materiales
11.
Braz Dent J ; 34(2): 14-20, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37194852

RESUMEN

The aim was to evaluate in vitro cytotoxicity and genotoxicity of Bio-C Repair (BCR), compared to Endosequence BC Root Repair (ERRM), MTA Angelus (MTA-Ang), and MTA Repair HP (MTA-HP). MC3T3 osteoblastic cells were exposed to extracts of the repairing bioceramic cements. After 1, 3, and 7 days, cytotoxicity and genotoxicity were evaluated by MTT and Micronucleus tests, respectively. Cells not exposed to biomaterials were used as a negative control. Data were compared using ANOVA two-way, followed by the Tukey Test (α=5%). MTA-Ang and MTA-HP showed no difference in relation to control regarding cytotoxicity in any experimental times. BCR and ERRM reduced cell viability after 3 and 7 days (p<0.05); however, the reduction caused by BCR was less than that caused by ERRM. Considering the micronucleus formation, all biomaterials caused an increase after 3 and 7 days (p<0.05), being greater for the BCR and ERRM groups. It can be concluded that BCR is non-cytotoxic in osteoblastic cells, as well as MTA-Ang e MTA Repair HP. BCR and ERRM showed greater genotoxicity than others tested biomaterials.


Asunto(s)
Compuestos de Calcio , Materiales de Obturación del Conducto Radicular , Compuestos de Calcio/toxicidad , Ensayo de Materiales , Materiales de Obturación del Conducto Radicular/toxicidad , Silicatos/toxicidad , Óxidos/toxicidad , Materiales Biocompatibles , Combinación de Medicamentos , Compuestos de Aluminio/toxicidad
12.
Braz Dent J ; 34(1): 29-38, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36888842

RESUMEN

The aim of this study was to evaluate the physicochemical properties, cytotoxicity and bioactivity of a ready-to-use bioceramic material, Bio-C Repair (Angelus), in comparison with White MTA (Angelus) and Biodentine (Septodont). The physicochemical properties of setting time, radiopacity, pH, solubility, dimensional and volumetric changes were evaluated. Biocompatibility and bioactivity were assessed in Saos-2 osteoblast cell cultures by the MTT assay 3-(4,5-Dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide), Neutral Red (NR), Alizarin Red (ARS), and cell migration tests. Statistical analysis was performed by ANOVA, Tukey or Bonferroni tests (α = 0.05). Bio-C Repair had the longest setting time (p < 0.05), but radiopacity and solubility were accordance with the ISO 6876/2012 standards, besides linear expansion. Bio-C Repair and MTA had similar volumetric change (p > 0.05); lower than Biodentine (p < 0.05). All the materials evaluated had an alkaline pH. Bio-C Repair was cytocompatible and promoted mineralized nodule deposition in 21 days and cell migration in 3 days. In conclusion, Bio-C Repair had adequate radiopacity above 3mm Al, solubility less than 3%, dimensional expansion, and low volumetric change. In addition, Bio-C Repair promoted an alkaline pH and presented bioactivity and biocompatibility similar to MTA and Biodentine, showing potential for use as a repair material.


Asunto(s)
Óxidos , Materiales de Obturación del Conducto Radicular , Ensayo de Materiales , Óxidos/química , Compuestos de Calcio/toxicidad , Compuestos de Calcio/química , Silicatos/toxicidad , Silicatos/química , Combinación de Medicamentos , Compuestos de Aluminio/química , Materiales de Obturación del Conducto Radicular/toxicidad
13.
Aust Endod J ; 49 Suppl 1: 508-514, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-36480411

RESUMEN

The function of root canal sealer was to achieve an appropriate three-dimensional filling effect by filling the root canal and some irregular lumen, thereby inhibiting the residual bacteria. There were many types of sealers, but research to find the most suitable ones was still ongoing. In recent years, researchers had continuously improved the performance of sealers by developing new sealers or adding active ingredients to the sealers. However, most sealers exhibit varying degrees of cytotoxicity and tissue responses, which affect clinical therapy efficacy. This review describes different technical approaches, and recent research progress in the biocompatibility evaluation of root canal sealers and provides brief insights into this field by summarising the performance studies of different root canal sealers.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Materiales de Obturación del Conducto Radicular/toxicidad , Materiales de Obturación del Conducto Radicular/uso terapéutico , Cavidad Pulpar , Tratamiento del Conducto Radicular , Proyectos de Investigación , Resultado del Tratamiento , Resinas Epoxi/toxicidad , Resinas Epoxi/uso terapéutico , Ensayo de Materiales
14.
Braz Oral Res ; 36: e063, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36507750

RESUMEN

Modified formulations of calcium silicate repair materials with additives have been developed to enhance handling, consistency, biocompatibility and bioactivity. Considering the relevance of osteoblastic cell response to mineralized tissue repair, human osteoblastic cells (Saos-2 cells overexpressing BMP-2) were exposed to mineral trioxide aggregate (MTA) (with calcium tungstate - CaWO4), MTA HP Repair, Bio-C Repair and Bio-C Pulpo. Cell viability was assessed by 3-(4,5-dimethylthiazol)-2,5-diphenyltetrazolium bromide (MTT) and neutral red (NR), and cell death, by flow cytometry. Gene expression of bone morphogenetic protein 2 (BMP-2), runt-related transcription factor 2 (RUNX-2), and alkaline phosphatase (ALP) osteogenic markers were evaluated by real-time polymerase chain reaction (RT-qPCR). ALP activity and alizarin red staining (ARS) were used to detect mineralization nodule deposition. Bioactive cements presented no cytotoxic effect, and did not induce apoptosis at the higher dilution (1:12). MTA, Bio-C Repair and Bio-C Pulpo exhibited higher ALP activity than the control group (P < 0.05) after 7 days. MTA, MTA HP and Bio-C Pulpo affected the formation of mineralized nodules (p < 0.05). Exposure to all cement extracts for 1 day increased BMP-2 gene expression. RUNX-2 mRNA was greater in MTA, MTA HP and Bio-C Repair. MTA, MTA HP and Bio-C Pulpo increased the ALP mRNA expression, compared with BMP-2 unexposed cells (P < 0.05). Calcium silicate cements showed osteogenic potential and biocompatibility in Saos-2 cells transfected BMP-2, and increased the mRNA expression of BMP-2, RUNX-2, and ALP osteogenic markers in the BMP-2 transfected system, thereby promoting a cellular response to undertake the mineralized tissue repair.


Asunto(s)
Proteína Morfogenética Ósea 2 , Materiales de Obturación del Conducto Radicular , Humanos , Compuestos de Calcio/farmacología , Silicatos/farmacología , Compuestos de Aluminio/farmacología , Óxidos/farmacología , Resinas Acrílicas , Fosfatasa Alcalina , Combinación de Medicamentos , ARN Mensajero , Células Cultivadas , Materiales de Obturación del Conducto Radicular/toxicidad , Ensayo de Materiales
15.
Eur Endod J ; 7(2): 129-134, 2022 06.
Artículo en Inglés | MEDLINE | ID: mdl-35786579

RESUMEN

OBJECTIVE: This study aimed to assess the genotoxicity and cytotoxicity of Sealer Plus BC (SBC), AH Plus (AHP) and MTA Fillapex (MTF). METHODS: Human periodontal ligament dental stem cells (hPDLSCs) from third molars were isolated and cultured in a clonogenic medium. Cells were maintained in an incubator, and cell growth was monitored daily. hPDLSCs were characterised under flow cytometry and stem cell surface markers. The tested groups were a control group, SBC, AHP and MTF. Each sealer was prepared according to the manufacturer's instructions and placed in a clonogenic medium to produce a conditioned media. Conditioned media were then diluted to 10% to be placed in contact with culture cells in cell viability assay afterwards. The cells were harvested and plated into 96 wells culture plates. Genotoxicity was assessed by evaluation of micronucleus formation and cytotoxicity by MTT-based assay. All experiments were performed in triplicate. Data normality was verified by the Kolmogorov-Smirnov test. Statistical analysis for genotoxicity was performed with Kruskal-Wallis and Dunn's tests and two-way ANOVA for cytotoxicity, both with a significance level of 5%. RESULTS: Cells expressed typical levels of mesenchymal stem cell surface markers. No differences in the number of micronuclei were observed among all groups (P>0.05). In all periods analysed (24, 48, and 72 h), the sealers presented statistically different results for cell viability (P<0.05), with SBC presenting the lowest cytotoxicity, followed by the control group, MTF, and AHP. CONCLUSION: All sealers presented low genotoxicity, and Sealer Plus BC presented the lowest cytotoxicity.


Asunto(s)
Ligamento Periodontal , Materiales de Obturación del Conducto Radicular , Compuestos de Calcio , Medios de Cultivo Condicionados , Humanos , Materiales de Obturación del Conducto Radicular/toxicidad , Silicatos , Células Madre
16.
Swiss Dent J ; 132(9): 586-597, 2022 09 05.
Artículo en Inglés | MEDLINE | ID: mdl-35536041

RESUMEN

Periapical tissue may be exposed to root canal filling materials in consequence of root canal therapy. There is scant scientific data about the biocompatibility of root canal filling materials of various chemistry on the periapical area. This study aimed to investigate the effects of different root canal sealers and their eluates on human alveolar osteoblasts in terms of cell proliferation, adhesion, morphology and gene expression in vitro. Five endodontic sealers (AH Plus®, Apexit®, Tubli-Seal®, Real Seal SE®, EndoRez®) and one gutta-percha obturation material (BeeFill®) were tested. Human alveolar osteoblasts derived from 3 different donors following incubation with sealer eluates after 24 h and 72 h were investigated by means of qPCR (gene expression). Morphological reactions of the alveolar osteoblasts were measured by culturing the cells for 3 d, and 7 d and 14 d, respectively, followed by scanning electron microscopy (morphology, adhesion) and fluorescence imaging of the actin cytoskeleton (morphology, proliferation). A repeated measures analysis was performed and p-values were adjusted by Tukey. While all sealers influenced the cell morphology and the expression of genes associated with apoptosis (Casp3), proliferation (histone H3), and inflammation (interleukin-6 and matrix metalloproteinases 1 and 3), mainly AH Plus® and Apexit® yielded a regular actin cytoskeleton and beneficial gene expression patterns. Regarding cell adhesion, only AH Plus® supported proper anchorage for alveolar osteoblasts. Our results provide evidence for the biocompatibility of epoxy resin-based endodontic sealers, i.e. AH Plus®, while other sealers proved cytotoxic for alveolar osteoblasts. Further studies are needed for understanding the bone cell reactions after endodontic treatment and the clinical decision-making regarding the sealer of choice for root canal fillings.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Resinas Epoxi/toxicidad , Gutapercha/efectos adversos , Humanos , Ensayo de Materiales , Materiales de Obturación del Conducto Radicular/toxicidad , Obturación del Conducto Radicular/métodos , Tratamiento del Conducto Radicular
17.
J Appl Biomater Funct Mater ; 20: 22808000221076325, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35164598

RESUMEN

Many types of endodontic root canal sealers have been employed for the purpose of filling voids and irregularities in root canals, as well as reducing/removing bacterial remnants/remains. Sealers are available in various formulations, and research work to find the most appropriate ones is still ongoing. Recently, many kinds of novel root canal sealers have been introduced under various commercial names. However, most sealers are known to exhibit different levels of cytotoxicity on tissues which would result in prolonged wound healing, inflammation, and bone resorption. Preferably, sealers need to have tolerable biological and physico-chemical properties along with biocompatibility. Additives promoting the biocompatibility and bioactivity of sealers are of major concern in clinical applications. The aim of this review was to compare, evaluate, and analyze comparatively the cytotoxic effects, biocompatibility, and antimicrobial properties of recently used root canal sealers. A comprehensive literature search was made to identify their properties involving biocompatibility and cytotoxicity. In general, the sealers reported in recent literature exhibited favorable biological features in comparison to conventional ones. They promoted better cell viability and biocompatibility. The incorporation of additives influences favorably the potential negative effects. However, it has been highlighted that there is a lack of well-designed long-term clinical applications, and more in vitro and in vivo research work would be helpful to confirm the sustainability of the sealers for further clinical practice.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Supervivencia Celular , Cavidad Pulpar , Resinas Epoxi , Ensayo de Materiales , Materiales de Obturación del Conducto Radicular/toxicidad
18.
Int Endod J ; 55 Suppl 2: 346-369, 2022 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-35124840

RESUMEN

Materials used for endodontics and with direct contact to tissues have a wide range of indications, from vital pulpal treatments to root filling materials and those used in endodontic surgery. In principle, interaction with dental materials may result in damage to tissues locally or systemically. Thus, a great variety of test methods are applied to evaluate a materials' potential risk of adverse biological effects to ensure their biocompatibility before commercialization. However, the results of biocompatibility evaluations are dependent on not only the tested materials but also the test methods due to the diversity of these effects and numerous variables involved. In addition, diverse biological effects require equally diverse assessments on a structured and planned approach. Such a structured assessment of the materials consists of four phases: general toxicity, local tissue irritation, pre-clinical tests and clinical evaluations. Various types of screening assays are available; it is imperative to understand their advantages and limitations to recognize their appropriateness and for an accurate interpretation of their results. Recent scientific advances are rapidly introducing new materials to endodontics including nanomaterials, gene therapy and tissue engineering biomaterials. These new modalities open a new era to restore and regenerate dental tissues; however, all these new technologies can also present new hazards to patients. Before any clinical usage, new materials must be proven to be safe and not hazardous to health. Certain international standards exist for safety evaluation of dental materials (ISO 10993 series, ISO 7405 and ISO 14155-1), but researchers often fail to follow these standards due to lack of access to standards, limitation of the guidelines and complexity of new experimental methods, which may cause technical errors. Moreover, many laboratories have developed their testing strategy for biocompatibility, which makes any comparison between findings more difficult. The purpose of this review was to discuss the concept of biocompatibility, structured test programmes and international standards for testing the biocompatibility of endodontic material biocompatibility. The text will further detail current test methods for evaluating the biocompatibility of endodontic materials, and their advantages and limitations.


Asunto(s)
Endodoncia , Materiales de Obturación del Conducto Radicular , Materiales Biocompatibles , Materiales Dentales , Humanos , Modelos Teóricos , Proyectos de Investigación , Materiales de Obturación del Conducto Radicular/toxicidad
19.
BMC Oral Health ; 22(1): 6, 2022 01 11.
Artículo en Inglés | MEDLINE | ID: mdl-35012572

RESUMEN

BACKGROUND: Freshly mixed root canal sealers when proximate the periapical tissues, trigger varying degrees of cytotoxicity/inflammatory reactions. Simvastatin, a class of the drug statin, is a widely used cholesterol-lowering agent with additional anti-inflammatory activities. This study assessed the effects of simvastatin on cytotoxicity and the release of IL-6 (Interleukin-6) production when incorporated in zinc oxide eugenol and methacrylate resin-based sealers. METHODS: Experimental groups consisted of conventional zinc oxide eugenol and methacrylate based-EndoREZ sealers (ZE & ER respectively) and 0.5 mg/mL simvastatin incorporated sealers (ZES & ERS). L929 mouse fibroblast cells were exposed to freshly mixed experimental sealers and evaluated for cytotoxicity (MTT assay) and inflammation levels (inflammatory marker IL-6 for ELISA) at various time intervals (0h, 24h and 7th day). The values were compared to the cell control (CC; L929 cells alone) and solvent control (SC; L929 cells + DMSO) groups. All the experiments were conducted in triplicates and subjected to statistical analysis using IBM SPSS Statistics software. Non parametric tests were conducted using Kruskal-Wallis and Friedman tests for inter-group and intra-group comparisons respectively. Pairwise comparison was conducted by post hoc Dunn test followed by Bonferroni correction. P values < 0.05 were considered statistically significant. RESULTS: All the experimental groups (ZE, ER, ZES, ERS) exhibited varying degree of cytotoxicity and IL-6 expression compared to the control groups CC and SC. The cell viability for ZE and ER decreased on day 7 as compared to 24 h. ZES and ERS had higher viable cells (75.93% & 79.90%) compared to ZE and ER (54.39% & 57.84%) at all time periods. Increased expression of IL-6 was observed in ZE & ER (25.49 pg/mL & 23.14 pg/mL) when compared to simvastatin incorporated ZE & ER (ZES-12.70 pg/mL & ERS-14.68 pg/mL) at all time periods. Highest level of cytotoxicity and inflammation was observed in ZE compared to all the other groups on day 7. CONCLUSIONS: Addition of 0.5 mg/mL of simvastatin to the sealers (ZES and ERS) decreased the cytotoxicity in the freshly mixed state and reduces their inflammatory effect.


Asunto(s)
Interleucina-6 , Materiales de Obturación del Conducto Radicular , Animales , Citocinas , Cavidad Pulpar , Resinas Epoxi , Humanos , Ensayo de Materiales , Ratones , Materiales de Obturación del Conducto Radicular/toxicidad , Simvastatina/farmacología , Cemento de Óxido de Zinc-Eugenol
20.
J Trace Elem Med Biol ; 68: 126856, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34560425

RESUMEN

BACKGROUND: This study aimed to track the toxic ions released by MTA Fillapex, BioRoot RCS, and an experimental tricalcium silicate-based sealer (CEO) into local and distant tissues as well as to investigate their potential adverse effects. In addition, the chemical constituents of the sealers were also evaluated. The main components of the dry powders, pastes, and mixed sealers were characterized. MATERIAL AND METHODS: Dry powder and sealer discs were each set for 72 h and their main components were characterized by energy dispersive X-ray spectroscopy. Polyethylene tubes filled with sealers were used to measure silicon and calcium ions. Polyethylene tubes filled with sealers or empty tubes were implanted into the dorsal connective tissue of Wistar rats. On days 7, 15, 30, and 45, the animals were euthanized and their brains, livers, kidneys, and subcutaneous tissues were removed and processed to determine the concentrations of chromium, cobalt, copper, lead, iron, magnesium and nickel using an inductively coupled plasma optical emission spectrometer. RESULTS: The main compounds in all sealers were carbon, oxygen, silicon, and calcium. MTA Fillapex release more Si while highest levels of Si were found in presence of BioRoot. The release of Si and Ca ions promoted by MTA Fillapex raise by time. No traces of cobalt, chromium, or magnesium were detected in any tissue. Irrespective of the sealer, no traces of copper and lead were found in the subcutaneous tissue; however, they were observed in the organs. The highest concentration of iron was identified in the liver. All sealers exhibited similar nickel traces in the brain, kidney, and liver except for MTA Fillapex, which demonstrated levels higher than CEO in the subcutaneous tissue on day 7. Tracing nickel ions over time revealed that lowest concentrations were found in subcutaneous tissue. CONCLUSION: Taken together, our data demonstrate that CEOs have chemical compositions similar to those of other commercial sealers. Furthermore, none of them exhibited a threat to systemic health. Moreover, the minimal amounts of iron and nickel detected were not related to the sealers.


Asunto(s)
Materiales de Obturación del Conducto Radicular , Animales , Ratas , Calcio , Compuestos de Calcio , Cromo , Cobalto , Cobre , Resinas Epoxi , Hierro , Magnesio , Ensayo de Materiales , Níquel , Óxidos/toxicidad , Polietilenos , Ratas Wistar , Materiales de Obturación del Conducto Radicular/toxicidad , Silicatos , Silicio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...