Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Tipo de estudio
Intervalo de año de publicación
1.
BMC Infect Dis ; 18(1): 68, 2018 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-29409447

RESUMEN

BACKGROUND: Nosocomial infections are a major setback in the healthcare delivery system especially in developing countries due to the limited resources. The roles played by medical care equipment and work surfaces in the transmission of such organisms have inevitably contributed to the elevated mortality, morbidity and antibiotic resistances. METHODS: A total 138 samples were collected during the study from Kawolo general hospital. Swab samples were collected from various work surfaces and fomites which consisted of; beds, sink taps, infusion stands, switches, work tables and scissors. Cultures were done and the susceptibility patterns of the isolates were determined using Kirby Bauer disc diffusion method. Data was analyzed using Stata 13 and Microsoft Excel 2013 packages. RESULTS: A total of 44.2% (61/138) of the collected swab specimens represented the overall bacterial contamination of the sampled articles. Staphylococcus aureus and Klebsiella pneumoniae accounted for the highest bacterial contaminants constituting of 75.4% (46/61) and 11.5% (7/61) respectively. Infusion stands and patient beds were found to have the highest bacterial contamination levels both constituting 19.67% (12/61). The highest degree of transmission of organisms to patients was found to be statistically significant for patient beds with OR: 20.1 and P-value 8X10- 4. Vancomycin, ceftriaxone and ciprofloxacin were the most effective antibiotics with 100%, 80% and 80% sensitivity patterns among the isolates respectively. Multi-drug resistant (MDR) Staphylococcus aureus accounted for 52% (24/46) with 4% (1/24) classified as a possible extensively drug resistant (XDR) whereas Gram negative isolates had 27% (4/15) MDR strains out of which 50%(2/4) were classified as possible pan-drug resistant (PDR). CONCLUSION: The high prevalence of bacterial contaminants in the hospital work environment is an indicator of poor or ineffective decontamination. The study findings reiterate the necessity to formulate drug usage policies and re-examine effectiveness of decontamination and sterilization practices within Kawolo general hospital. We also recommend installation of a sound Microbiology unit at the hospital to take on susceptibility testing to check on the empirical use of antibiotics as a way of reducing the rampant elevations in drug resistances.


Asunto(s)
Klebsiella pneumoniae/aislamiento & purificación , Staphylococcus aureus/aislamiento & purificación , Equipo Quirúrgico/microbiología , Antibacterianos/farmacología , Ropa de Cama y Ropa Blanca/microbiología , Ceftriaxona/farmacología , Ciprofloxacina/farmacología , Farmacorresistencia Microbiana/efectos de los fármacos , Bacterias Gramnegativas/efectos de los fármacos , Bacterias Gramnegativas/aislamiento & purificación , Hospitales Generales , Humanos , Klebsiella pneumoniae/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Mesas de Operaciones/microbiología , Staphylococcus aureus/efectos de los fármacos , Vestimenta Quirúrgica/microbiología , Uganda , Vancomicina/farmacología
2.
Z Orthop Unfall ; 154(2): 157-62, 2016 Apr.
Artículo en Alemán | MEDLINE | ID: mdl-26844853

RESUMEN

Integrated ventilation systems with low turbulence displacement flow (TAV) are generally legally required in the architectural structure of operating theatres. However, it seems that the instruments laid out on sterile covered tables do not have the best possible protection from bacteria. Within an operating theatre, different bacteria counts are possible on the instruments. This prospective controlled study was conducted to demonstrate the influence of instrument tables with integrated horizontal flow on contamination with pathogens in comparison with conventional tables. In an operating theatre (OT) with a ceiling legally appropriate for TAV (2.40 m × 1.20 m), microbiological samples were placed on a table with integrated TAV flow (n = 100) and on a conventional instrument table (n = 100). The routine qualification of the OT was on an ongoing basis and was in accordance with DIN 1946-4: 1999 standards (in accordance with DIN measurement of recovery time 1946-4: 12-2008). This corresponds to the OT of the room class Ib. The results show significant differences between the two tables. The bacteria count and the percentage of contamination were many times higher on the conventional table. It is important to understand that the instruments are not completely protected against contamination after opening the pack and during the operation. Remedial measures are possible to optimise the sterility the instrument table.


Asunto(s)
Microbiología del Aire , Contaminación de Equipos/prevención & control , Prótesis Articulares/microbiología , Mesas de Operaciones/microbiología , Instrumentos Quirúrgicos/microbiología , Ventilación/instrumentación , Diseño de Equipo , Análisis de Falla de Equipo , Alemania , Prótesis de Cadera/microbiología , Prótesis de la Rodilla/microbiología , Quirófanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...