Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
J Comp Physiol B ; 190(5): 535-545, 2020 09.
Artículo en Inglés | MEDLINE | ID: mdl-32617717

RESUMEN

The role of the marine elasmobranch gastrointestinal tract in nitrogen-recycling and osmotic homeostasis has become increasingly apparent, with the gut microbial community likely playing a significant role converting urea, an important osmolyte in elasmobranchs, into ammonia. The Pacific spiny dogfish can experience and tolerate reduced environmental salinities, yet how this environmental challenge may affect the microbiome, and consequently nitrogen transport across the gut, is as of yet unknown. In the present study, excised gut sac preparations were made from dogfish acclimated to the following: full-strength seawater (C), low salinity for 7 days (LS), and after acute transfer of LS-acclimated fish to full-strength SW for 6 h (AT). Significantly reduced microbial derived urease activity was observed in the mucosal saline of gut sac preparations from the LS (by 81%) and AT (by 89%) treatments relative to the C treatment. Microbial derived cellulase activity from mucosal saline samples tended to follow similar patterns. To further ensure an effective decrease in the spiral valve microbial population, an antibiotic cocktail was applied to the mucosal saline used for in vitro measurements of ion, water, and nitrogen flux in these gut sac preparations. This caused a further 57-61% decrease in the mucosal saline urease activity of the C and LS treatments. Overall, we observed relatively little flux across the stomach for all measured parameters aside from water movement, which switched from a net efflux in control fish to a net influx in acutely transferred fish, indicative of drinking. While no significant differences were observed in terms of nitrogen flux (urea or ammonia), we tended to see the accumulation of ammonia in the spiral valve lumen and a switch from efflux to influx of urea in control versus acutely transferred fish. The increased ammonia production likely occurs as a result of heightened metabolism in a challenging environment, while the retention and acquisition of urea is suggestive of nitrogen scavenging under nitrogen-limiting conditions.


Asunto(s)
Antibacterianos/farmacología , Tracto Gastrointestinal/efectos de los fármacos , Salinidad , Squalus acanthias/metabolismo , Amoníaco/sangre , Animales , Celulasa/metabolismo , Proteínas de Peces/metabolismo , Tracto Gastrointestinal/metabolismo , Mucosa Intestinal/efectos de los fármacos , Mucosa Intestinal/metabolismo , Masculino , Metales Ligeros/sangre , Urea/sangre , Ureasa/metabolismo
2.
Biol Trace Elem Res ; 196(2): 393-399, 2020 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-31691192

RESUMEN

The present study investigated the status of calcium and magnesium as well as essential trace elements including iodine, selenium, copper, iron, and zinc in adults residing in the Zhytomyr region of Ukraine. In addition, the relative risk of goiter occurrence was evaluated. In this comparative study, 40 adults without goiter (control group) and 16 adults with diagnosed nodular goiter (NG) were examined. Inductively coupled plasma optical emission spectrometry (ICP-OES) was used for the measurements of Mg, Ca, Se, Zn, Cu, and Fe in serum of patients with NG and control group. Patients with nodular goiter had lower serum values of Ca, Mg, Se, Cu, Fe, and Zn than those in the control group. The presence of mild iodine deficiency was evident in both groups with the median urinary iodine excretion (UIE) 80.5 µg/L in the control group and 64.5 µg/L in goiter group. There was a positive association between goiter presence and low concentration of Ca in serum (odds ratio (OR) = 2.29 (1.26-3.55), p < 0.05) in the NG group. High relative risk of goiter was observed at low concentrations of magnesium (OR = 3.33 (1.39-7.62), p < 0.05) and selenium (OR = 1.63, (1.16-1.78), p < 0.05) in comparison with OR values in the control group. Low concentrations of Ca, Mg, Zn, and Se in serum combined with reduced UIE resulted in the highest risk of goiter (OR = 12.5, (2.15-79.42), p < 0.01). This study proved that Thyroglobulin concentration in serum is the reliable indicator of nodular goiter. We also suggest that a combination of low concentrations of Ca, Mg, Zn, Cu, and Se in blood serum, and reduced iodine concentration in urine resulted in the highest risk of nodular goiter development.


Asunto(s)
Bocio Nodular/sangre , Hormonas Tiroideas/sangre , Oligoelementos/sangre , Adulto , Femenino , Humanos , Masculino , Metales Ligeros/sangre
3.
Biomed Khim ; 60(3): 378-88, 2014.
Artículo en Ruso | MEDLINE | ID: mdl-25019401

RESUMEN

Methods of whole blood trace element determination by Graphite furnace atomic absorption spectrometry (in the variant of Zeeman's modulation polarization spectrometry) have been proposed. They do not require preliminary sample digestion. Furnace programs, modifiers and blood dilution factors were optimized. Seronorm™ human whole blood reference materials were used for validation. Dynamic ranges (for undiluted blood samples) were: Al 8 ¸ 210 мg/L; Be 0.3 ¸ 50 мg/L; Cd 0.2 ¸ 75 мg/L; Сo 5 ¸ 350 мg/L; Cr 10 ¸ 100 мg/L; Mn 6 ¸ 250 мg/L; Ni 10 ¸ 350 мg/L; Pb 3 ¸ 240 мg/L; Se 10 ¸ 500 мg/L; Tl 2 ¸ 600 мg/L. Precision (RSD) for the middle of dynamic range ranged from 5% for Mn to 11 for Se.


Asunto(s)
Calcógenos/sangre , Metales Pesados/sangre , Metales Ligeros/sangre , Espectrofotometría Atómica/métodos , Humanos , Estándares de Referencia , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Espectrofotometría Atómica/instrumentación
4.
J Bone Joint Surg Br ; 92(5): 634-8, 2010 May.
Artículo en Inglés | MEDLINE | ID: mdl-20435998

RESUMEN

We investigated the role of ion release in the assessment of fixation of the implant after total knee replacement and hypothesised that ion monitoring could be a useful parameter in the diagnosis of prosthetic loosening. We enrolled 59 patients with unilateral procedures and measured their serum aluminium, titanium, chromium and cobalt ion levels, blinded to the clinical and radiological outcome which was considered to be the reference standard. The cut-off levels for detection of the ions were obtained by measuring the levels in 41 healthy blood donors who had no implants. Based on the clinical and radiological evaluation the patients were divided into two groups with either stable (n = 24) or loosened (n = 35) implants. A significant increase in the mean level of Cr ions was seen in the group with failed implants (p = 0.001). The diagnostic accuracy was 71% providing strong evidence of failure when the level of Cr ions exceeded the cut-off value. The possibility of distinguishing loosening from other causes of failure was demonstrated by the higher diagnostic accuracy of 83%, when considering only patients with failure attributable to loosening. Measurement of the serum level of Cr ions may be of value for detecting failure due to loosening when the diagnosis is in doubt. The other metal ions studies did not have any diagnostic value.


Asunto(s)
Artroplastia de Reemplazo de Rodilla , Metales Pesados/sangre , Metales Ligeros/sangre , Falla de Prótesis , Anciano , Anciano de 80 o más Años , Biomarcadores/sangre , Estudios de Cohortes , Femenino , Humanos , Iones/sangre , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Reoperación
5.
Tohoku J Exp Med ; 185(4): 253-62, 1998 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-9865472

RESUMEN

Titanium (Ti), cobalt (Co) and chromium (Cr) element concentrations in the whole blood and urine specimen in 40 patients with cementless total knee arthroplasty were determined by the electrothermal atomic absorption spectrophotometry. Their ages ranged from 55 to 78 years (mean, 65 years). Twenty of them had loosening of prosthesis and underwent revision surgery, including 4 subjects with Ti-6Al-4V alloy prosthesis and 16 subjects with Co-Cr-Mo alloy prosthesis. The other 20 patients had well-functioning stable prosthesis, including 5 subjects with Ti-6Al-4V alloy prosthesis and 15 subjects with Co-Cr-Mo alloy prosthesis. The mean duration of prostheses implantation in patients with loosened or well-functioning prostheses were 6.5 and 4.0 years, respectively. The control group consisted of 20 age-matched normal subjects who did not undergo any metal implant surgery. Analysis of variance showed that the metal element concentrations in the whole blood, either Co, Cr or Ti, was statistically higher in the patients with loosened prosthesis than the other two groups. However, the metal element concentrations in the urine did not show any difference. The linear regression analysis showed a moderate positive relationship between the metal element concentrations, either Co or Cr elements, in whole blood and urine only in the patients with loosened prostheses. In conclusion, elevated concentration of metal elements may indicate a loosening of prosthesis while the clinical significance of the metal element concentration in the urine needs further investigation.


Asunto(s)
Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla , Metales Ligeros/sangre , Metales Ligeros/orina , Falla de Prótesis , Anciano , Artritis/cirugía , Cromo/sangre , Cromo/orina , Cobalto/sangre , Cobalto/orina , Femenino , Humanos , Masculino , Análisis por Apareamiento , Persona de Mediana Edad , Titanio/sangre , Titanio/orina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...