Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.567
Filtrar
1.
Anal Chim Acta ; 1307: 342620, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38719413

RESUMEN

BACKGROUND: Pharmacokinetic studies are pivotal in drug development, focusing on absorption, distribution, and excretion of active compounds. Effective sample preparation methods play a crucial role in these studies. Traditional techniques like protein precipitation and liquid-liquid extraction often involve toxic solvents and are time-consuming. Recently, deep eutectic solvent (DES) has emerged as an eco-friendly alternative due to its high efficiency, low cost, and low toxicity. This study introduces a novel sample pretreatment method using CO2-switchable DES in liquid-liquid microextraction (LLME) to enhance speed, accuracy, and sensitivity in complex biological samples analysis. RESULTS: A liquid-liquid microextraction sample pretreatment method based on switchable DES combined with high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the analysis of urine and tissue samples. The method was optimized through systematic investigation of key parameters, including DES type, volume, molar ratio, pH, vortex time, gas purge time, and salt addition. The resulting procedure exhibited satisfying linearity (r2 ≥ 0.9958), good precision (RSD ≤6.01 %), desirable recovery (52.44%-98.12 %) and matrix effect (86.22%-119.30 %), and the accuracy and precision of stability were within the ±15 % limit. The proven methods were further applied to urinary excretion study and tissue distribution study of Nelumbinis plumula (NP) extract. The results indicated that the total cumulative excretion of liensinine, isoliensinine and neferine in urine within 240 h was 4.96 %, 0.66 % and 0.44 %, respectively. The tissue distribution study showed that alkaloids mainly distribute in liver, kidney, and spleen. SIGNIFICANCE: This research introduces a groundbreaking technique distinguished by its simplicity, speed, cost-effectiveness, and environmental friendliness. This approach, utilizing CO2-switchable DES as an extraction solvent for LLME, integrates deproteinization and removal of interfering molecules into a single step. This integration showcases its efficiency and convenience, demonstrating significant promise for various applications in the analysis of biological samples. Additionally, this study provides the first report on urinary excretion and tissue distribution of alkaloids from NP using a DES-LLME method. These findings offer valuable insights into the in vivo behavior of herbal medicine, enhancing understanding of pharmacological actions and facilitating clinical rational administration.


Asunto(s)
Dióxido de Carbono , Disolventes Eutécticos Profundos , Microextracción en Fase Líquida , Espectrometría de Masas en Tándem , Microextracción en Fase Líquida/métodos , Dióxido de Carbono/química , Disolventes Eutécticos Profundos/química , Animales , Distribución Tisular , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión , Masculino , Ratas , Ratas Sprague-Dawley
2.
Molecules ; 29(9)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38731560

RESUMEN

2, 6-diisopropylaniline (2, 6-DIPA) is a crucial non-intentionally organic additive that allows the assessment of the production processes, formulation qualities, and performance variations in biodegradable mulching film. Moreover, its release into the environment may have certain effects on human health. Hence, this study developed simultaneous heating hydrolysis-extraction and amine switchable hydrophilic solvent vortex-assisted homogeneous liquid-liquid microextraction for the gas chromatography-mass spectrometry analysis of the 2, 6-DIPA additive and its corresponding isocyanates in poly(butylene adipate-co-terephthalate) (PBAT) biodegradable agricultural mulching films. The heating hydrolysis-extraction conditions and factors influencing the efficiency of homogeneous liquid-liquid microextraction, such as the type and volume of amine, homogeneous-phase and phase separation transition pH, and extraction time were investigated and optimized. The optimum heating hydrolysis-extraction conditions were found to be a H2SO4 concentration of 2.5 M, heating temperature of 87.8 °C, and hydrolysis-extraction time of 3.0 h. As a switchable hydrophilic solvent, dipropylamine does not require a dispersant. Vortex assistance is helpful to speed up the extraction. Under the optimum experimental conditions, this method exhibits a better linearity (0.0144~7.200 µg mL-1 with R = 0.9986), low limit of detection and quantification (0.0033 µg g-1 and 0.0103 µg g-1), high extraction recovery (92.5~105.4%), desirable intra- and inter-day precision (relative standard deviation less than 4.1% and 4.7%), and high enrichment factor (90.9). Finally, this method was successfully applied to detect the content of the additive 2, 6-DIPA in PBAT biodegradable agricultural mulching films, thus facilitating production process monitoring or safety assessments.


Asunto(s)
Aminas , Compuestos de Anilina , Cromatografía de Gases y Espectrometría de Masas , Interacciones Hidrofóbicas e Hidrofílicas , Microextracción en Fase Líquida , Solventes , Microextracción en Fase Líquida/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Solventes/química , Aminas/química , Aminas/análisis , Compuestos de Anilina/química , Hidrólisis , Poliésteres/química
3.
J Chromatogr A ; 1722: 464852, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38581974

RESUMEN

Xiangdan Injection are commonly used traditional Chinese medicine formulations for the clinical treatment of cardiovascular diseases. However, the trace components of Dalbergia odorifera in Xiangdan Injection pose a challenge for evaluating its quality due to the difficulty of detection. This study proposes a technology combining dispersive liquid-liquid microextraction and back-extraction (DLLME-BE) along with Bar-Form-Diagram (BFD) to address this issue. The proposed combination method involves vortex-mixing tetradecane, which has a lower density than water, with the sample solution to facilitate the transfer of the target components. Subsequently, a new vortex-assisted liquid-liquid extraction step is performed to enrich the components of Dalbergia odorifera in acetonitrile. The sample analysis was performed on HPLC-DAD, and a clear overview of the chemical composition was obtained by integrating spectral and chromatographic information using BFD. The combination of BFD and CRITIC-TOPSIS strategies was used to optimize the process parameters of DLLME-BE. The determined optimal sample pre-treatment process parameters were as follows: 200 µL extraction solvent, 60 s extraction time, 50 µL back-extraction solvent, and 90 s back-extraction time. Based on the above strategy, a total of 29 trace components, including trans-nerolidol, were detected in the Xiangdan Injection. This combination technology provides valuable guidance for the enrichment analysis of trace components in traditional Chinese medicines.


Asunto(s)
Dalbergia , Medicamentos Herbarios Chinos , Microextracción en Fase Líquida , Microextracción en Fase Líquida/métodos , Cromatografía Líquida de Alta Presión/métodos , Medicamentos Herbarios Chinos/química , Medicamentos Herbarios Chinos/análisis , Dalbergia/química , Límite de Detección , Acetonitrilos/química , Reproducibilidad de los Resultados
4.
Anal Methods ; 16(18): 2938-2947, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38668806

RESUMEN

The nature and proportions of hydrocarbons in the cuticle of insects are characteristic of the species and age. Chemical analysis of cuticular hydrocarbons allows species discrimination, which is of great interest in the forensic field, where insects play a crucial role in estimating the minimum post-mortem interval. The objective of this work was the differentiation of Diptera order insects through their saturated cuticular hydrocarbon compositions (SCHCs). For this, specimens fixed in 70 : 30 ethanol : water, as recommended by the European Association for Forensic Entomology, were submitted to solid-liquid extraction followed by dispersive liquid-liquid microextraction, providing preconcentration factors up to 76 for the SCHCs. The final organic extract was analysed by gas chromatography coupled with flame ionization detection (GC-FID), and GC coupled with mass spectrometry was applied to confirm the identity of the SCHCs. The analysed samples contained linear alkanes with the number of carbon atoms in the C9-C15 and C18-C36 ranges with concentrations between 0.1 and 125 ng g-1. Chrysomya albiceps (in its larval stage) showed the highest number of analytes detected, with 21 compounds, while Lucilia sericata and Calliphora vicina the lowest, with only 3 alkanes. Non-supervised principal component analysis and supervised orthogonal partial least squares discriminant analysis were performed and an optimal model to differentiate specimens according to their species was obtained. In addition, statistically significant differences were observed in the concentrations of certain SCHCs within the same species depending on the stage of development or the growth pattern of the insect.


Asunto(s)
Dípteros , Cromatografía de Gases y Espectrometría de Masas , Hidrocarburos , Animales , Hidrocarburos/análisis , Dípteros/química , Cromatografía de Gases y Espectrometría de Masas/métodos , Microextracción en Fase Líquida/métodos , Entomología Forense/métodos , Análisis de Componente Principal , Análisis Discriminante
5.
Artículo en Inglés | MEDLINE | ID: mdl-38564965

RESUMEN

In the present work, a new microextraction procedure combined with gas chromatography-mass spectrometry has been developed for the analysis of several aliphatic amines from urine sample. The sample preparation method was a continuous homogenous liquid phase microextraction that was based on in-situ preparation of 4-chlorophenol: choline chloride deep eutectic solvent. The deep eutectic solvent was prepared by passing the mixture of related compounds through a syringe barrel filled with exothermic salts (calcium chloride and potassium bromide). The released heat by dissolving the salts and increasing the solution ionic strength assists the formation of the deep eutectic solvent. The influence of various factors on the efficiency of the proposed procedure including salts amount, flow rate, pH, salting-out effect, and extraction solvent volume was studied. The calibration curves were linear broadly over the concentration range of 1.2-250 ng mL-1 with coefficient of determinations ≥0.996. The enrichment factors were in the range of 188-246 and the limits of detection and quantification were 0.16-0.37 and 0.56-1.2 ng mL-1, respectively. Based on the results, the offered method was sensitive, rapid, eco-friendly, and efficient for extracting and determining aliphatic amines in urine samples.


Asunto(s)
Microextracción en Fase Líquida , Solventes/química , Microextracción en Fase Líquida/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Disolventes Eutécticos Profundos , Sales (Química) , Colina , Límite de Detección
6.
Anal Methods ; 16(16): 2585-2596, 2024 Apr 25.
Artículo en Inglés | MEDLINE | ID: mdl-38606467

RESUMEN

Excessive dietary polyamines (PAs), including putrescine (PUT), spermine (SPM), and spermidine (SPD), have become a worldwide concern due to their carcinogenicity and reduced shelf life. A modern miniaturized on-chip electromembrane extraction (EME) has been applied to extract these compounds from chicken breast samples. This method is based fundamentally on ionic compounds' electrostatic attraction, diffusion, and solubility in the acceptor phase. The chemical structure of polyamines enables their efficient extraction using an electric driving force on a microchip device. HCl solution (0.1 mol L-1) was applied as an aqueous acceptor solvent. Dispersive liquid-liquid microextraction was performed after EME to facilitate joining three-phase EME to GC-MS and improve the merit figures. The total ranges of 3.77-7.89 µg g-1, 3.48-7.02 µg g-1, and 0.78-2.20 µg g-1 were acquired as PUT, SPM and SPD concentrations in chicken breast, respectively. The results demonstrate that the level of PAs in fresh chicken breast samples is not concerning, but it may reduce the quality of chicken meat over time. This novel analytical technique has several advantages: high recovery, substantial quickness, remarkable selectivity, and good enrichment factors. This emerging method could be generalized to other studies to analyze different foodstuffs.


Asunto(s)
Pollos , Cromatografía de Gases y Espectrometría de Masas , Microextracción en Fase Líquida , Poliaminas , Animales , Microextracción en Fase Líquida/métodos , Cromatografía de Gases y Espectrometría de Masas/métodos , Poliaminas/química , Poliaminas/análisis , Dispositivos Laboratorio en un Chip , Carne/análisis , Membranas Artificiales
7.
Environ Monit Assess ; 196(5): 454, 2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38622372

RESUMEN

This work presents a sensitive and accurate analytical method for the determination of phenytoin at trace levels in domestic wastewater and synthetic urine samples by gas chromatography-mass spectrometry (GC-MS) after the metal sieve-linked double syringe liquid-phase microextraction (MSLDS-LPME) method. A metal sieve was produced in our laboratory in order to disperse water-immiscible extraction solvents into aqueous media. Univariate optimization studies for the selection of proper extraction solvent, extraction solvent volume, mixing cycle, and initial sample volume were carried out. Under the optimum MSLDS-LPME conditions, mass-based dynamic range, limit of quantitation (LOQ), limit of detection (LOD), and percent relative standard deviation (%RSD) for the lowest concentration in calibration plot were figured out to be 100.5-10964.2 µg kg-1, 150.6 µg kg-1, 45.2 µg kg-1, and 9.4%, respectively. Detection power was improved as 187.7-folds by the developed MSLDS-LPME-GC-MS system while enhancement in calibration sensitivity was recorded as 188.0-folds. In the final step of this study, the accuracy and applicability of the proposed system were tested by matrix matching calibration strategy. Percent recovery results for domestic wastewater and synthetic urine samples were calculated as 95.6-110.3% and 91.7-106.6%, respectively. These results proved the accuracy and applicability of the proposed preconcentration method, and the obtained analytical results showed the efficiency of the lab-made metal sieve apparatus.


Asunto(s)
Microextracción en Fase Líquida , Contaminantes Químicos del Agua , Cromatografía de Gases y Espectrometría de Masas/métodos , Aguas Residuales , Fenitoína/análisis , Contaminantes Químicos del Agua/análisis , Monitoreo del Ambiente/métodos , Solventes/química , Agua/análisis , Microextracción en Fase Líquida/métodos , Límite de Detección
8.
Environ Monit Assess ; 196(5): 485, 2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38684572

RESUMEN

Herein, we aimed to develop a new environmentally friendly liquid-liquid microextraction (LLME) method based on hydrophobic deep eutectic solvent (hDES) synthesized using biodegradable dl-menthol and decanoic acid for the spectrophotometric determination of toxic basic fuchsin dye in environmental water samples. The parameters affecting the extraction efficiency such as pH, mole ratio, and volume of hDES (1:2) and type and volume of organic solvent, sample volume, times of vortex, ultrasonic bath and centrifuge, ionic strength, and matrix effect were investigated and optimized. Under optimal conditions, the calibration curve showed linearity in the range of 7.4-167 µg L-1 with a coefficient of determination of 0.9994. The limit of detection, intra-day and inter-day precision, and recovery values were 2.25 µg L-1, 2.46% and 4.45%, and 105 ± 3%, respectively. The preconcentration and enrichment factors were found to be 30 and 61.5, respectively. The proposed hDES-LLME methodology was successfully applied to the environmental water samples to detect toxic BF dye (95-105%). Finally, the ecological impact of the suggested method was evaluated using the analytical eco-scale (PPS:88), complementary green analytical procedure indexe (ComplexGAPI), and the Analytical GREEnness tool (0.63). The assessment results showed that the presented analytical method can be regarded as a green LLME approach for the determination of the BF in water.


Asunto(s)
Microextracción en Fase Líquida , Mentol , Contaminantes Químicos del Agua , Microextracción en Fase Líquida/métodos , Contaminantes Químicos del Agua/análisis , Contaminantes Químicos del Agua/química , Mentol/química , Disolventes Eutécticos Profundos/química , Interacciones Hidrofóbicas e Hidrofílicas , Tecnología Química Verde/métodos , Colorantes/química , Monitoreo del Ambiente/métodos
9.
Talanta ; 274: 126038, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38579419

RESUMEN

Herein, a High-Throughput Semi-automated Emulsive Liquid-Liquid Microextraction (HTSA-ELLME) method was developed to detect Succinate Dehydrogenase Inhibitor (SDHI) fungicides in food samples via UHPLC-MS/MS. The Oil-in-Water (O/W) emulsion comprising a hydrophobic extractant and water was dilutable with the aqueous sample solution. Upon injecting the primary emulsion into the sample solution, a secondary O/W emulsion was formed, allowing SDHI fungicides to be extracted. Subsequently, a NaCl-saturated solution was injected in the secondary O/W emulsion as a demulsifier to rapidly separate the extractant, eliminating the need for centrifugation. A 12-channel electronic micropipette was used to achieve a high-throughput semi-automation of the novel sample pretreatment. The linear range was 0.003-0.3 µg L-1 with R2 > 0.998. The limit of detection was 0.001 µg L-1. The HTSA-ELLME method successfully detected SDHI fungicides in water, juice, and alcoholic beverage samples, with recoveries and relative standard deviations of 82.6-106.9% and 0.8-5.8%, respectively. Unlike previously reported liquid-liquid microextraction approaches, the HTSA-ELLME method is the first to be both high-throughput and semi-automated and may aid in designing pesticide pretreatment processes in food samples.


Asunto(s)
Bebidas Alcohólicas , Jugos de Frutas y Vegetales , Fungicidas Industriales , Microextracción en Fase Líquida , Espectrometría de Masas en Tándem , Microextracción en Fase Líquida/métodos , Espectrometría de Masas en Tándem/métodos , Cromatografía Líquida de Alta Presión/métodos , Fungicidas Industriales/análisis , Jugos de Frutas y Vegetales/análisis , Bebidas Alcohólicas/análisis , Emulsiones/química , Agua/química , Contaminación de Alimentos/análisis , Automatización
10.
Chemosphere ; 354: 141706, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38484993

RESUMEN

Aliphatic aldehydes are a class of organic compounds containing aldehyde groups, which are widespread, and closely related to people's daily life and health. In this work, a series of terpenes based hydrophobic deep eutectic solvents were designed and synthesized using hexafluoroisopropanol as hydrogen bond donor and menthol/thymol as hydrogen bond acceptor. Then they are used as extraction solvent in dispersive liquid-liquid microextraction for extracting and determining seven aliphatic aldehydes from drinking water and alcoholic beverage combined with high performance liquid chromatography-ultraviolet. Due to the fact that these hydrophobic deep eutectic solvents are liquid at the room temperature, a density greater than that of water, a lower viscosity (≤26.10 mPa s, 25 °C), after extraction and centrifugation, the microvolume DES-rich phase in the bottom is convenient for collection and direct analysis without further dissolution or dilution with organic solvents. Some factors affecting the extraction recovery were optimized by one-variable-at-a-time and response surface methodology. Under the optimal conditions, the enrichment factors for the seven aliphatic aldehydes were 48-56. The method had good performance: linear ranges of 1.0-200, 0.5-200, 0.2-200, 0.4-400, 1.0-400, 0.4-400 and 0.4-400 µg L-1 for seven aliphatic aldehydes (r2 ≥ 0.9949), limits of detection of 0.1-0.5 µg L-1, intra-day and inter-day precisions <4.9%. The recoveries of seven aliphatic aldehydes ranged from 76.0 to 119.0%. The proposed dispersive liquid-liquid microextraction method is simple, rapid, highly efficient, and green, which effectively reduces the amount of toxic chemical reagents used and their impact on the environment. Rapid and efficient detection of aliphatic aldehydes helps ensure a healthy diet and has great application prospects in food safety analysis.


Asunto(s)
Agua Potable , Microextracción en Fase Líquida , Humanos , Terpenos , Disolventes Eutécticos Profundos , Microextracción en Fase Líquida/métodos , Aldehídos , Límite de Detección , Solventes/química , Cromatografía Líquida de Alta Presión/métodos , Bebidas Alcohólicas
11.
Food Chem ; 447: 139024, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-38493687

RESUMEN

This manuscript describes the development of a novel liquid phase microextraction (LPME) method for the extraction and determination of Zn (II), Fe (II), Pb (II), and Cd (II) in various infant/baby food and supplements products. The method is based on vortex-assisted extraction combined with a switchable-hydrophilicity solvent (SHS) sample preparation. The SHS, which undergoes reversible phase changes triggered by pH change, enables selective extraction and easy phase separation. A flame atomic absorption spectroscopy was used in the final determination step. Optimization studies revealed, that the optimal pH of the sample solution (after digestion) during analytes extraction is 5.5. A l-proline is added to the sample (375 mM) to ensure the complexation of the target metal cations. After the complexation step, 750 µL of SHS - a N, N-Dimethylcyclohexylamine along with 0.9 mL of 2 M of acetic acid solution is added (hydrophilicity switch-on stage) and mixed manually to obtain a homogeneous solution. In the last stage, 0.45 mL of 10 M NaOH solution (hydrophilicity switch-off stage) is added to the sample solution and a vortex for 100 s is applied to ensure the effective extraction and separation of the complex containing the analytes. At this stage, a cloudy solution is immediately obtained. Finally, the effective phase separation is obtained at the centrifugation step (4000 rpm for 2 mins). The method limit of detection was as 0.03, 0.009, 0.6, and 0.2 ng/L for Zn (II), Fe (II), Cd (II), and Pb (II) respectively with RSD% below 2.0 %. The analysis of certified reference materials and real samples proved the full applicability of the method for routine analysis, contributing to the field of heavy metal analysis and ensuring the safety of baby products. According to the AGREE methodology, this method can be named as green analytical chemistry method with a score of 0.77.


Asunto(s)
Cadmio , Microextracción en Fase Líquida , Humanos , Solventes/química , Plomo , Microextracción en Fase Líquida/métodos , Alimentos Infantiles , Interacciones Hidrofóbicas e Hidrofílicas , Zinc , Límite de Detección
12.
Food Chem ; 447: 139036, 2024 Jul 30.
Artículo en Inglés | MEDLINE | ID: mdl-38518615

RESUMEN

In this study, a UV-Vis Spectroscopy-based method was developed for the determination of tin(IV) in epilobium parviflorum tea samples after preconcentration. The preconcentration process was carried out using the liquid-liquid microextraction technique. Before starting the analysis, optimization studies were carried out for the variables likely to affect the experimental results. As a result of the analyzes performed under optimum conditions, the detection limit of our method was calculated as 16.83 µg/L. The percent relative standard deviation value was calculated as 1.25% (n = 8) and linearity was found in the range of 10-1000 µg/L. Recovery experiments were performed on epilobium parviflorum tea samples using the matrix matching method. As a result of the analyzes made on teas belonging to three different brands, recovery results ranging from 92 to 117% were obtained.


Asunto(s)
Epilobium , Microextracción en Fase Líquida , Solventes , Disolventes Eutécticos Profundos , Estaño , Microextracción en Fase Líquida/métodos , Análisis Espectral , , Límite de Detección
13.
Talanta ; 273: 125847, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38452590

RESUMEN

This study investigates the contamination of cow milk with aluminum (Al) and its potential health implications, particularly for children. Cow milk samples were collected from both nonexposed and exposed areas in Sindh, based on the source of livestock drinking water (fresh canals and groundwater). An environmental friendly deep eutectic solvent (DES) was used with ultrasonic-assisted dispersive liquid-liquid microextraction (UDLLµE) to enrich trace amounts of Al in whey milk and water samples. The enriched samples were then analyzed using inductively coupled plasma optical emission spectrometry. Certified reference materials were employed to validate the methodology, and the experimental results exhibited acceptable conformity. The DES-based dispersive liquid-liquid microextraction method was environmental friendly, devoid of acids and oxidizing agents, and used safe and inexpensive components for routine trace metal analysis in diverse samples. The resulting data revealed that Al in whey milk samples was observed in the range of 31-45 %, corresponding to (160-270) µg L-1 and (700-1035) µg L-1 in nonexposed and exposed whole cow milk samples, respectively. Additionally, it was observed that milk boiling in Al utensil for 10-20 min enhanced the Al levels from 3 to 8% of its total contents in milk samples.


Asunto(s)
Microextracción en Fase Líquida , Leche , Niño , Bovinos , Animales , Humanos , Solventes/química , Leche/química , Suero Lácteo , Aluminio/análisis , Disolventes Eutécticos Profundos , Microextracción en Fase Líquida/métodos , Límite de Detección
14.
Artículo en Inglés | MEDLINE | ID: mdl-38547699

RESUMEN

In this research, a method known as a hollow fiber-liquid-phase microextraction was employed to extract and concentrate free metoprolol from plasma samples. The extracted analyte was subsequently determined using high-performance liquid chromatography coupled with a diode-array detector. Several parameters, including hollow fiber length, sonication time, extraction temperature, and salt addition, were investigated and optimized to enhance extraction efficiency. After extracting the analyte under optimum conditions from plasma samples, the enrichment factor and extraction recovery were 50 and 86 %, respectively. Moreover, the method exhibited detection and quantification limits of 0.41 and 1.30 ng mL-1, respectively. The analysis of real samples demonstrated satisfactory relative recoveries in the range of 91-99 %.


Asunto(s)
Microextracción en Fase Líquida , Metoprolol , Microextracción en Fase Líquida/métodos , Cromatografía Líquida de Alta Presión/métodos , Cloruro de Sodio , Sonicación
15.
J Chromatogr A ; 1719: 464753, 2024 Mar 29.
Artículo en Inglés | MEDLINE | ID: mdl-38394784

RESUMEN

In this study, MIL-88(Fe) coordinated to carboxymethyl cellulose fibers was successfully synthesized, characterized, and utilized as a nanocomposite for the dispersive solid phase microextraction of butachlor and acetochlor. These analytes served as representative analytes for acetanilide herbicides (AHs) present in real samples. Effective parameters on the extraction efficiency were investigated to maximize the analytical performance of the developed method. Under optimized conditions, which encompassed sorbent amount of 12 mg, solution pH of 7.0, 4.0 min of the vortex time, 3.0 min of the extraction time, chloroform as desorption agent and no salt addition, the developed method exhibited remarkable figures of merit, such as high linearity (R2> 0.99), low limits of detection of 0.90 ng mL-1, substantial preconcentration factors (between 213 and 228), relative recoveries in the range of 90.8% to 109%, and good repeatability with relative standard deviations equal or below 7.2%. After validation, the developed method was applied to detect AHs in various cereal and agricultural soil samples.


Asunto(s)
Herbicidas , Microextracción en Fase Líquida , Nanocompuestos , Microextracción en Fase Sólida/métodos , Herbicidas/análisis , Carboximetilcelulosa de Sodio , Grano Comestible/química , Suelo , Acetanilidas/química , Extracción en Fase Sólida/métodos , Microextracción en Fase Líquida/métodos
16.
Artículo en Inglés | MEDLINE | ID: mdl-38417274

RESUMEN

Clomipramine (CLP) is a tricyclic antidepressant drug, and its determination in biological samples is of high importance in clinical and forensic evaluations to assure appropriate drug concentrations. In the present study, benzoic acid was employed as a pH-switchable hydrophilicity solvent (SHS) for the microextraction of CLP from authentic human urine samples prior to its determination by high performance liquid chromatography-ultraviolet detection (HPLC-UV). The microextraction protocol was based on the phase transition of the SHS through pH alteration that resulted in its rapid dispersion and simultaneous phase separation. The obtained solid was collected in a syringe filter, dissolved in methanol, and analyzed. The main parameters that affected the efficiency of the microextraction procedure were studied and optimized to ensure high extraction efficiency for CLP and the analytical method was validated. Under optimum conditions, good linearity was observed between 0.05 and 5.0 µg mL-1. The limit of detection and limit of quantification were found to be 0.015 and 0.05 µg mL-1, respectively. The RSD values for intra-day repeatability and inter-day precision were 2.4-8.9 % and 1.7-9.1 %, respectively. The relative recovery values were within 90.0 and 110.0 % in all cases, demonstrating good method accuracy. The proposed SHS microextraction showed cost-efficiency, handling simplicity, and rapidity resulting in enhanced sample throughput. Moreover, the proposed method exhibited a green character and good applicability based on its evaluation by Green Analytical Procedure Index and Blue Applicability Grade Index.


Asunto(s)
Clomipramina , Microextracción en Fase Líquida , Humanos , Clomipramina/orina , Solventes , Microextracción en Fase Líquida/métodos , Interacciones Hidrofóbicas e Hidrofílicas , Cromatografía Líquida de Alta Presión , Concentración de Iones de Hidrógeno , Límite de Detección
17.
J Chromatogr A ; 1717: 464686, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38310697

RESUMEN

For the first time, benzophenone and related compounds were investigated in açaí-based food products. An extraction method based on the dilute-and-shoot approach, combined with the use of in-situ formed metal-containing ionic liquids (MCILs) followed by high-performance liquid chromatography, was developed and validated. A nickel and cobalt-based MCIL, in addition to the ratio of MCIL to lithium bis[(trifluoromethyl)sulfonyl]imide salt ([Li+][NTf2-]) for the ensuing metathesis reaction, were optimized. Parameters of the in-situ formed MCIL step, namely, the amount of MCIL, centrifugation time, and dilution step, were analyzed using a multivariate optimization approach, including central composite rotatable design and Derringer and Suich's tool. Optimum extraction performance was achieved using 50.98 mg of nickel-based MCIL and a MCIL to ([Li+][NTf2-]) ratio of 1:3 (m/m), a centrifuge time of 22 min, and 10.53 mL of water for the dilution step. This condition was used to perform analytical validation, which yielded satisfactory results with R2 ≥ 0.995, limits of detection (LOD) ranging from 0.0025 to 0.5 mg kg-1, and limits of quantification (LOQ) between 0.008 and 1.5 mg kg-1. The recovery rate ranged from 87 % to 107 % and precision values (as percent relative standard deviation) were equal or lower than 13 %. The validated method was applied to 25 samples of açaí-based food products purchased from Brazil and the United States. None of the samples showed analyte concentration levels above the LOD. The method's suitability was demonstrated for future monitoring of complex samples, such as foodstuffs.


Asunto(s)
Líquidos Iónicos , Microextracción en Fase Líquida , Líquidos Iónicos/química , Níquel , Agua/química , Metales , Cromatografía Líquida de Alta Presión , Litio , Iones , Benzofenonas , Microextracción en Fase Líquida/métodos
18.
J Chromatogr A ; 1717: 464692, 2024 Feb 22.
Artículo en Inglés | MEDLINE | ID: mdl-38320432

RESUMEN

A simple, fast, and efficient ultrasonic-assisted supramolecular solvent microextraction combined with high performance liquid chromatography method was developed for the determination of coumarins in Cortex fraxini, including esculin, esculetin and fraxetin. In this study, a novel supramolecular solvent was prepared with 1-octanol, tetrahydrofuran and water for the first time, and its composition, viscosity, density, structure, and micromorphology were characterized. The prepared supramolecular solvent exhibited vesicular structures and had the characteristics of low viscosity. Through single-factor experiments, response surface methodology and artificial neural network-genetic algorithm, the optimal extraction conditions were obtained as follows: NaCl concentration of 1 mol mL-1, pH value of 10, solid-liquid ratio of 10:1, vortex time of 30 s, ultrasonic power of 100 W, ultrasonic temperature of 60 °C, ultrasonic time of 15 min, centrifugation speed of 5000 rpm, and centrifugation time of 1 min. The results demonstrated that the artificial neural network model exhibited maximum R-values of 0.98703, 0.97440, 0.99836, and 0.95447 for training, testing, validation, and all dataset, respectively. The minimum mean square errors were 0.75, 10.15, 1.99, and 2.63, respectively. This indicated that the predicted values were almost consistent with the actual values. Under the optimal conditions, the total extraction yields of target analytes reached 2.80 %. The calibration curves for each analyte exhibited excellent linearity within the linear range (r > 0.9993). The limits of detection and quantification ranged from 4.87 to 6.55 ng mL-1 and 16.24 to 21.84 ng mL-1, respectively. The recoveries ranged from 98.71 % to 111.01 % with relative standard deviations of less than 3.6 %. The present method had the advantages of short extraction time (15 min) and less solvent consumption (0.5 mL). The prepared supramolecular solvent was proved to have great potential in extracting coumarins from medicinal plants.


Asunto(s)
Medicamentos Herbarios Chinos , Microextracción en Fase Líquida , Solventes/química , Ultrasonido , Microextracción en Fase Líquida/métodos , Cumarinas , Medicamentos Herbarios Chinos/química , Cromatografía Líquida de Alta Presión/métodos , Algoritmos , Límite de Detección
19.
Food Chem ; 445: 138694, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38364492

RESUMEN

In this study, a novel ionic liquid (3-(3-chloro-2-hydroxypropyl)-1-butyl-1H-imidazol-3-ium hexafluorophosphate, (IL-2) was synthesized and characterized by FT-IR, NMR (1H,13C,31P) spectroscopy, and TGA. Two microextraction methods, ultrasonic assisted ionic liquid dispersive liquid liquid microextraction (USA-IL-DLLME) and ultrasonic assisted-temperature controlled ionic liquid DLLME, have been developed for preconcentration of Brilliant Blue FCF (E133) from some food products by the sythesized IL-2. For optimization of the both methods, several parameters such as volume of IL-2, pH, temperature, ultrasonication time, extraction time, centrifugation time, and salt effect were investigated. The obtained results for both methods under optimum conditions were compared. According to these results, the best limit of detection (4.55 µg L -1), enrichment factor (58), preconcentration factor (50), linear range (15-80 µg L -1), relative standard deviation % (1.15 %) were obtained by use of USA-TC-IL-DLLME method. Furthermore, the developed USA-TC-IL-DLLME method was succesfully applied to real samples for the preconcentration of Brilliant Blue FCF.


Asunto(s)
Bencenosulfonatos , Líquidos Iónicos , Microextracción en Fase Líquida , Líquidos Iónicos/química , Microextracción en Fase Líquida/métodos , Temperatura , Interleucina-2 , Espectroscopía Infrarroja por Transformada de Fourier
20.
Anal Methods ; 16(11): 1593-1602, 2024 Mar 14.
Artículo en Inglés | MEDLINE | ID: mdl-38404220

RESUMEN

In this study, a sample preparation procedure based on salt-induced homogeneous liquid-liquid extraction performed in a narrow-bore tube was used for the preconcentration and extraction of Zn(II), Cu(II), and Cd(II) ions from honey samples. To perform the procedure, a mixture of working solution containing sodium chloride, acetonitrile, and a synthesized deep eutectic solvent (as an extraction solvent) was transferred into a narrow tube filled with solid sodium chloride up to a specific level. As the solution flowed through the tube, tiny droplets of the extraction solvent were formed at the boundary between the solution and salt layer. The droplets moved upwards in the tube and eventually collected as a distinct layer on the top of the solution. The separated phase was removed and dispersed into ionized water. After centrifugation, tiny droplets of the extraction solvent containing the analytes were sedimented at the bottom of the tube. The concentrated analytes were measured using flame atomic absorption spectrophotometry. The linear ranges and extraction recoveries were obtained in the ranges of 1.5-100 µg kg-1 and 89.6-94.8%, respectively. The detection limits ranged from 0.35 to 0.48 µg kg-1. Low relative standard deviations (C = 10 µg L-1, n = 6) of 3.1, 2.8, and 3.4% for Zn(II), Cu(II), and Cd(II), respectively, were obtained. Finally, the optimized method was successfully used in determination of concentration of the selected heavy metal ions in various honey samples.


Asunto(s)
Miel , Microextracción en Fase Líquida , Solventes , Cloruro de Sodio , Cadmio , Disolventes Eutécticos Profundos , Microextracción en Fase Líquida/métodos , Extracción Líquido-Líquido/métodos , Cloruro de Sodio Dietético , Zinc
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA