1.
Blood Press Monit ; 29(4): 212-216, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946333

RESUMEN

OBJECTIVE: A novel automated auscultatory upper arm cuff blood pressure (BP) monitor KOROT V2 Doctor (InBody BPBIO280KV) was developed for professional use. An electronic stethoscope embedded in the device cuff records the Korotkoff sounds, which are graphically displayed during deflation allowing visual evaluation by the healthcare professional. The device provides automated measurements of BP and this study evaluated its accuracy. METHODS: The requirements of the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) and its Amendment 1.2020-01 were applied. Participants were recruited to fulfill the age, sex, BP, arm circumference, and cuff distribution criteria of the Universal Standard and its Amendment in a general population using the same arm sequential measurement method. Three cuffs of the test device were tested for arm circumference 23-28, 28-35, and 33-42 cm. RESULTS: Data from 85 individuals were analyzed [mean age: 56.4 ±â€…16.0 (SD) years, 50 men, arm circumference 23-42 cm]. For validation Criterion 1, the mean difference ±SD between the test device and reference BP readings (N = 255) was -1.3 ± 6.0/1.5 ± 5.0 mmHg (systolic/diastolic; threshold ≤5 ±â€…8 mmHg). For Criterion 2, the SD of the averaged BP differences per individual (N = 85) was 4.61/3.48 mmHg (systolic/diastolic; threshold ≤6.82/6.78 mmHg). CONCLUSION: The KOROT V2 Doctor (InBody BPBIO280KV) device for professional use, which provides automated auscultatory measurements with visual display of the Korotkoff sounds, comfortably fulfills all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in a general population and can be recommended for clinical use.


Asunto(s)
Auscultación , Determinación de la Presión Sanguínea , Monitores de Presión Sanguínea , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea/normas , Auscultación/instrumentación , Brazo , Presión Sanguínea
2.
Vasc Health Risk Manag ; 20: 333-339, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39070216

RESUMEN

Purpose: The performance of Omron HEM-1026 (HCR-1901T2 / HCR-1902T2) for monitoring blood pressure (BP) in the upper arm was validated in accordance with the International Organization for Standardization (ISO) 81060-2:2018+amendment (Amd)1:2020 protocol. Methods: The device was assessed in 101 participants who fulfilled the inclusion criteria, including arm circumference range and systolic and diastolic BP provided by the protocol. Data validation and analysis were performed according to the manufacturer's instructions. Results: In the ISO 81060-2:2018+Amd 1:2020 validation procedure (criterion 1), the mean ± standard deviation (SD) of the differences between the test device and reference BP was -2.1 ± 7.24/-0.6 ± 5.63 mmHg (systolic/diastolic). These data fulfilled the ISO81060-2:2018+Amd1:2020 requirement of ≤5±≤8 mmHg. The mean differences between the two observers and Omron HEM-1026 were -2.1 ± 5.71 mmHg for systolic BP and -0.6 ± 4.81 mmHg for diastolic BP, fulfilling criterion 2 with an SD of ≤ 6.62 for systolic BP and ≤ 6.91 for diastolic BP. The two ISO criteria were fulfilled. Conclusion: The Omron HEM-1026 BP monitor fulfilled the requirements of the ISO 81060-2:2018+Amd 1:2020 validation standard and can be recommended for home BP measurements in the general population.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Presión Sanguínea , Diseño de Equipo , Valor Predictivo de las Pruebas , Humanos , Reproducibilidad de los Resultados , Masculino , Femenino , Persona de Mediana Edad , Anciano , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/normas , Adulto , Monitores de Presión Sanguínea/normas , Variaciones Dependientes del Observador , Extremidad Superior/irrigación sanguínea
4.
Blood Press Monit ; 29(4): 217-220, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38774977

RESUMEN

OBJECTIVE: We investigated the accuracy of the OMRON HEM-7361T automated oscillometric blood pressure (BP) monitor in the differentiation between atrial fibrillation and sinus rhythm. METHODS: An approximately equal number of patients with persistent atrial fibrillation and individuals with sinus rhythm were recruited from outpatients and inpatients of Ruijin Hospital, Shanghai, China. BP was measured three times consecutively with a 30-s interval with the OMRON HEM-7361T automatic electronic BP monitor for atrial fibrillation detection. A hand-held single lead electrocardiogram device was used for simultaneous electrocardiogram recordings. RESULTS: The device accurately identified atrial fibrillation in 100 (99.0%) of the 101 patients, with only 1 patient incorrectly classified as non-atrial fibrillation. The device correctly identified 99 (95.2%) of the 104 participants with sinus rhythm as non-atrial fibrillation, with five participants incorrectly classified as atrial fibrillation. The device had a positive predictive value of 95.2%, negative predictive value of 99.0%, and overall accuracy of 97.1%. Among the six misclassified participants, one with atrial fibrillation had a heart rate of 65 beats/min, and four of the five participants with sinus rhythm had cardiac arrhythmias (atrial or ventricular premature beat in one participants, sinus tachycardia in one participant, and both arrhythmias in one participant). CONCLUSION: The OMRON HEM-7361T BP monitor is accurate in the differentiation between atrial fibrillation and sinus rhythm. Whether the device is sufficiently accurate in the differentiation between atrial fibrillation and other cardiac arrhythmias remains under investigation.


Asunto(s)
Fibrilación Atrial , Humanos , Fibrilación Atrial/fisiopatología , Fibrilación Atrial/diagnóstico , Femenino , Masculino , Persona de Mediana Edad , Anciano , Electrocardiografía/instrumentación , Monitores de Presión Sanguínea , Arritmia Sinusal/fisiopatología , Arritmia Sinusal/diagnóstico , Presión Sanguínea , Adulto , Determinación de la Presión Sanguínea/instrumentación , Anciano de 80 o más Años
5.
Blood Press Monit ; 29(5): 272-275, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38774982

RESUMEN

PURPOSE: The performance of the Omron HEM-7372T1-AZAZ (BP5460) in monitoring blood pressure (BP) in the upper arm was validated in accordance with the International Organization for Standardization (ISO) 81060-2:2018 (E) and amendment (Amd)1:2020 protocol. METHODS: The device was used to assess 98 participants who fulfilled the inclusion criteria, including the range of arm circumference and systolic and diastolic BP, in accordance with the protocol. Data validation and analysis were performed according to the manufacturer's instructions. RESULTS: In the ISO validation procedure (criterion 1), the mean ± SD of the differences between test device readings and reference BP was 0.3 ±â€…6.17/3.6 ±â€…5.26 mmHg (systolic/diastolic). These data fulfilled the ISO requirements of ≤5±≤8 mmHg. The mean differences between the observer measurements and Omron HEM-7372T1-AZAZ (BP5460) readings were 0.3 ±â€…4.82 mmHg for systolic BP and 3.6 ±â€…4.78 mmHg for diastolic BP, fulfilling criterion 2 with SD values of ≤6.95 for SBP and ≤5.89 for DBP. Therefore, two ISO criteria were fulfilled. CONCLUSION: The Omron HEM-7372T1-AZAZ BP monitor fulfilled the requirements of the ISO validation standard. This device can be recommended for home BP measurements in the general population.


Asunto(s)
Determinación de la Presión Sanguínea , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Presión Sanguínea , Monitores de Presión Sanguínea/normas
6.
J Hypertens ; 42(9): 1538-1543, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38690918

RESUMEN

OBJECTIVE: A novel automated auscultatory upper-arm cuff blood pressure (BP) monitor for office use (KOROT P3 Accurate, previously InBody BPBIO480KV), which displays Korotkoff sound curves for each BP reading was recently developed. This study investigated whether the review of Korotkoff sound curves by healthcare professionals further improves the accuracy of the device by identifying unreliable BP readings. METHODS: Three observers assessed independently the morphology of Korotkoff sound curves of BP measurements obtained during an ISO 81060-2:2018 validation study, and classified them as of good, fair, or poor quality (low amplitude or sound intensity, aberrant morphology, background noise, signal artifact, auscultatory gap, irregular rhythm). The observers were blinded to the study BP measurements. RESULTS: Korotkoff sound curves of 255 BP readings obtained in 85 individuals were analyzed (mean age 57.3 ±â€Š15.0 years, 53 men). Of the SBP readings 80.4/12.2/7.4% were classified as good/fair/poor, and DBP 76.9/12.2/10.9%. Inter-observer agreement in detecting poor-quality curves was 84.7/83.1% (systolic/diastolic). Of poor-quality curves, 10.5/60.7% (systolic/diastolic) clustered in the same individuals. The validation criterion 1 [mean test-reference BP difference ≤5 ±â€Š8 (SD) mmHg] was satisfied for readings with good (0.1 ±â€Š4.9/0.3 ±â€Š3.8 mmHg, systolic/diastolic) and fair-quality curves (-0.4 ±â€Š6.4/0.2 ±â€Š5.0), but not for poor-quality ones (2.7 ±â€Š8.8/3.6 ±â€Š8.1). By excluding poor-quality readings (40 of 255), criterion 1 of the validation study was improved (0.2 ±â€Š4.9/0.2 ±â€Š3.9 versus 0.3 ±â€Š5.5/0.6 ±â€Š4.7 mmHg). CONCLUSION: The visual assessment of Korotkoff sounds generated during automated auscultatory BP measurement by the KOROT P3 Accurate professional monitor identifies unreliable readings and further improves the device accuracy.


Asunto(s)
Auscultación , Determinación de la Presión Sanguínea , Humanos , Masculino , Persona de Mediana Edad , Femenino , Determinación de la Presión Sanguínea/métodos , Determinación de la Presión Sanguínea/instrumentación , Adulto , Auscultación/métodos , Anciano , Presión Sanguínea/fisiología , Monitores de Presión Sanguínea , Reproducibilidad de los Resultados
7.
Blood Press ; 33(1): 2338208, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38591393

RESUMEN

OBJECTIVE: Some brachial cuffs for oscillometric blood pressure (BP) measurement are claimed to cover a wide range of upper-arm circumferences; however, their validation is rarely conducted. Our aim was to compare oscillometric BP measurements obtained with a universal cuff with those obtained with an appropriately sized cuff. METHODS: We utilised the Microlife B6 Connect monitor, conducting oscillometric BP measurements in a random sequence with both a universal cuff (recommended for arm circumferences from 22 to 42 cm) and an appropriately sized cuff (medium for circumference 22-32 cm and large for 32-42 cm). We included 91 individuals with an arm circumference of 22-32 cm and 64 individuals with an arm circumference of 32-42 cm. RESULTS: For arm circumferences > 32 cm, systolic and diastolic BP measured with the universal cuff was higher than that measured with the large cuff (systolic 6.4 mmHg, 95% confidence interval [CI]). 3.9-8.8, diastolic 2.4 mmHg, 95%CI, 1.2-3.7, p < 0.001 for both). Overestimation of BP with the universal cuff was statistically significant after correcting for the sequence of measurements. No statistical difference was found between the universal cuff and medium cuff for circumferences in the 22-32 cm range. The bladder size in the universal cuff matched the dimensions of the medium-sized cuff; however, the cuff was larger. CONCLUSION: Overestimation of BP measured with a universal cuff in persons with large arm circumferences is clinically important. It poses the risk of unnecessary initiation or intensification of antihypertensive medication in persons using the universal cuff.


What is the context?Clinical guidelines recommend individualisation of the size of the cuff used for blood pressure measurement according to the circumference of the upper arm.Many blood pressure monitors are sold with a single "universal" cuff claimed to cover a wide range of upper arm sizes.We compared blood pressure obtained with the Microlife B6 Connect monitor and a "universal" cuff with the results obtained with individual sized cuffs (medium size for arm circumference between 22 and 32 cm and large size for arm circumference between 32 and 42 cm).What is new?In persons with large upper arm circumference is the systolic blood pressure 6.4 mmHg higher and the diastolic blood pressure 2.4 mmHg higher with the universal cuff than with the individual-sized large cuff.What is the impact?The universal cuff overestimates blood pressure in persons with large arm circumference.


Asunto(s)
Determinación de la Presión Sanguínea , Extremidad Superior , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Oscilometría/métodos , Diástole , Monitores de Presión Sanguínea
8.
J Clin Hypertens (Greenwich) ; 26(6): 703-707, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38650108

RESUMEN

The aim of this study was to evaluate the accuracy of the single upper-arm cuff oscillometric blood pressure (BP) monitor RBP-9801 developed for office and home BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. A total of 105 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.3 ± 6.4/3.1 ± 5.8 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.24/5.03 mmHg (systolic/diastolic). The conclusion is that the RBP-9801 oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in the general population and can be recommended for clinic and self-use at home.


Asunto(s)
Determinación de la Presión Sanguínea , Hipertensión , Oscilometría , Humanos , Masculino , Femenino , Persona de Mediana Edad , Oscilometría/instrumentación , Oscilometría/normas , Hipertensión/diagnóstico , Hipertensión/fisiopatología , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/métodos , Determinación de la Presión Sanguínea/normas , Adulto , Monitores de Presión Sanguínea/normas , Presión Sanguínea/fisiología , Anciano , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/normas , Monitoreo Ambulatorio de la Presión Arterial/métodos , Reproducibilidad de los Resultados
9.
Blood Press Monit ; 29(4): 207-211, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38523458

RESUMEN

We aimed to validate the accuracy of the Mindray VS9 Vital Signs Monitor, which features the Mindray TrueBP inflation algorithm for oscillometric blood pressure (BP) measurement, to check if it complies with the International Organization for Standardization Standard (ISO 81060-2:2018) in a combined adult and pediatric population. A total of 86 participants, including both adult and pediatric subjects, were recruited. The distribution of their ages, gender, BPs and limb sizes all complied with the requirement of the ISO standard. The inflation and deflation algorithms were validated independently using the same-arm sequential BP measurement method. For each subject, the BP was first determined by two independent observers using a mercury sphygmomanometer (R1). The BP of the subject was then determined by the third observer using the test equipment (T1). Then, using a mercury sphygmomanometer, two independent observers were asked to determine the subject's BP (R2) again. R1-T1-R2 were considered a valid pair of data. This cycle continued until 3 pairs of valid data were achieved. We collected 258 pairs of valid BP data for the validation of the inflation and deflation algorithms respectively. For validation Criterion 1, the mean ± SD of the differences between the readings obtained from the test device and reference BP was 0.0 ±â€…6.6/-1.8 ±â€…7.1 mmHg (systolic/diastolic) when the deflation algorithm was used, and 2.4 ±â€…6.3/ 0.3 ±â€…6.9 mmHg (systolic/diastolic) when the inflation algorithm was used. For validation Criterion 2, the SD of the averaged BP differences between the test device and the reference BP per subject was 5.35/6.33 mmHg (systolic/diastolic) when the deflation algorithm was used, and 5.17/5.75 mmHg (systolic/diastolic) when the inflation algorithm was used. The VS9 Vital Signs Monitor fulfilled all the criteria in the ISO Standard. Moreover, the inflation algorithm had a shorter Measure Time (by 7-21 s) and lower maximum inflation pressure (by 9.7-22 mmHg). The VS9 Vital Signs Monitor fulfilled all the requirements of the ISO Standard (ISO 81060-2:2018) in a combined adult and pediatric population and is recommended for clinical use.


Asunto(s)
Determinación de la Presión Sanguínea , Humanos , Adulto , Masculino , Femenino , Niño , Adolescente , Persona de Mediana Edad , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Algoritmos , Anciano , Presión Sanguínea , Monitores de Presión Sanguínea/normas , Adulto Joven
10.
J Clin Monit Comput ; 38(3): 715-719, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38310593

RESUMEN

The standard method for qualitatively evaluating the dynamic response is to see if the gain of the amplitude spectrum curve approaches 1 (input signal = output signal) over the frequency band of the blood pressure waveform. In a previous report, Watanabe reported that Gardner's natural frequency and damping coefficient, which are widely used as evaluation methods, do not reflect the dynamic response of the circuit. Therefore, new parameters for evaluating the dynamic response of pressure monitoring circuits were desired. In this study, arterial pressure catheters with length of 30, 60, 150, and 210 cm were prepared, and a blood pressure wave calibrator, two pressure monitors with analog output and a personal computer were used to analyze blood pressure monitoring circuits. All data collection and analytical processes were performed using step response analysis program. The gain at 10 Hz was close to 1 and the systolic blood pressure difference was small in the short circuits (30 cm, 60 cm), and the gain at 10 Hz was 1.3-1.5 in the 150 cm circuit and over 1.7 in the 210 cm circuit. The difference in systolic blood pressure increased in proportion to the length of the circuit. It could also be inferred that the gain at 10 Hz should be less than 1.2 to meet a clinically acceptable blood pressure difference. In conclusion, the gain at 10 Hz is sufficiently useful as an indicator to determine the correct systolic blood pressure.


Asunto(s)
Determinación de la Presión Sanguínea , Presión Sanguínea , Humanos , Determinación de la Presión Sanguínea/métodos , Determinación de la Presión Sanguínea/instrumentación , Presión Sanguínea/fisiología , Procesamiento de Señales Asistido por Computador , Diseño de Equipo , Sístole , Calibración , Monitores de Presión Sanguínea , Algoritmos , Reproducibilidad de los Resultados , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Catéteres , Presión Arterial , Programas Informáticos
11.
Blood Press Monit ; 29(3): 161-165, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38390625

RESUMEN

OBJECTIVE: The aim of this study was to evaluate the accuracy of the Raycome model M2 oscillometric upper-arm blood pressure (BP) monitor developed for ambulatory BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018) at rest and during dynamic exercise. METHOD: Subjects were recruited to fulfill the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in the general population using the same arm sequential BP measurement method. Three cuffs of the test device were used for arm circumference 18-22 cm (small), 22-32 cm (medium) and 32-42 cm (large). RESULTS: For the general validation study, 106 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ±â€…SD of the differences between the test device and reference BP readings was 0.5 ±â€…6.2/-0.2 ±â€…5.1 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.23/4.50 mmHg (systolic/diastolic). In the ambulatory validation study ( N  = 35), the mean difference was 0.4 ±â€…5.9/-1.1 ±â€…5.8 mmHg. The Raycome model M2 performed well against the standard in both the general and ambulatory validations and the Bland-Altman plots did not show any systematic variation in the error. CONCLUSION: These data show that the Raycome model M2 monitor meets the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) and in the ambulatory setting, indicating its suitability for measuring BP in the general population.


Asunto(s)
Monitoreo Ambulatorio de la Presión Arterial , Humanos , Monitoreo Ambulatorio de la Presión Arterial/instrumentación , Monitoreo Ambulatorio de la Presión Arterial/normas , Masculino , Femenino , Persona de Mediana Edad , Adulto , Anciano , Monitores de Presión Sanguínea/normas , Hipertensión/fisiopatología , Hipertensión/diagnóstico , Presión Sanguínea
12.
Blood Press Monit ; 29(3): 144-148, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38390635

RESUMEN

OBJECTIVE: To determine the accuracy of the KOROT P3 Accurate (previously InBody BPBIO480KV) monitor, an automated auscultatory blood pressure (BP) measuring device developed for professional use, in people with extra-large arms according to the ISO81060-2 2018 protocol. METHODS: The KOROT P3 Accurate was tested in 37 subjects with upper-arm circumference ranging from >42 to 53 cm using a mercury sphygmomanometer coupled to a 20 × 40 cm tronco-conical cuff as the reference standard. RESULTS: The mean BP difference between the device and the observers' reference measurements was 1.2 ±â€…2.0 mmHg for systolic BP and 1.0 ±â€…2.0 mmHg for diastolic BP. These data were in agreement with criterion 1 of the protocol standard requirements (≤5 ±â€…8 mmHg). Also criterion 2 was satisfied being the standard deviations ± 1.7 mmHg for systolic BP and ± 1.6 for diastolic BP, well below the maximum values required by the protocol (±6.84/6.87 mmHg). Scatterplots of device-reference systolic and diastolic BP differences showed similar accuracy across the range of participants' BP, arm circumference and upper-arm slant angle. CONCLUSIONS: These data show that the KOROT P3 Accurate monitor satisfied the ISO 81060-2:2018 standard requirements in a special population of people with extra-large arms ranging from >42 to 53 cm.


Asunto(s)
Brazo , Determinación de la Presión Sanguínea , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Auscultación/instrumentación , Presión Sanguínea , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea
13.
J Anesth ; 38(2): 222-231, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38305914

RESUMEN

PURPOSE: This study aimed to compare non-invasive oscillometric blood pressure (NIBP) measurement with invasive arterial blood pressure (IBP) measurement in patients with sepsis. METHODS: We conducted a retrospective study to evaluate the agreement between IBP and NIBP using the Medical Information Mart for Intensive Care IV (MIMIC-IV) database. Paired blood pressure measurements of mean arterial pressure (MAP), systolic blood pressure (SBP), and diastolic blood pressure (DBP) were compared using Bland-Altman analysis and paired Student's t test. We also focus on the effect of norepinephrine (NE) on the agreement between the two methods and the association between blood pressure and mortality during intensive care unit (ICU) stay. RESULTS: A total of 96,673 paired blood pressure measurements from 6060 unique patients were analyzed in the study. In Bland-Altman analysis, the bias (± SD, 95% limits of agreement) was 6.21 mmHg (± 12.05 mmHg, - 17.41 to 29.83 mmHg) for MAP, 0.39 mmHg (± 19.25 mmHg, - 37.34 to 38.12 mmHg) for SBP, and 0.80 mmHg (± 12.92 mmHg, - 24.52 to 26.12 mmHg) for DBP between the two techniques. Similarly, large limits of agreement were shown in different groups of NE doses. NE doses significantly affected the agreement between IBP and NIBP. SBP between the two methods gave an inconsistent assessment of patients' risk of ICU mortality. CONCLUSION: IBP and NIBP were not interchangeable in septic patients. Clinicians should be aware that non-invasive MAP was clinically and significantly underestimated invasive MAP.


Asunto(s)
Presión Arterial , Sepsis , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Estudios Retrospectivos , Norepinefrina , Sepsis/diagnóstico , Monitores de Presión Sanguínea
14.
Blood Press Monit ; 29(3): 156-160, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38411950

RESUMEN

OBJECTIVE: To validate the noninvasive blood pressure monitoring function of the EDAN elite V5 patient monitor with reference invasive blood pressure monitoring equipment for clinical use in adults, adolescents or children according to the International Organization for Standardization (ISO) 81060-2:2018 standard. METHODS: Patients were recruited, and the ipsilateral sequential method was used for blood pressure measurement according to the standard. The validation results were assessed following the protocol and the Bland-Altman scatterplot was used to show the difference between the test device and reference invasive blood pressure results. RESULTS: A total of 71 patients were included in the study, with 35 and 36 patients for each iFAST and iCUFS mode, respectively. The validation results showed an average device-reference difference of -3.27 ±â€…5.60 mmHg for SBP and -0.09 ±â€…6.10 mmHg for DBP for the iFAST mode, and -2.04 ±â€…5.55 mmHg for SBP and -0.79 ±â€…5.86 mmHg for DBP for the iCUFS mode, respectively, which passed the criteria of the ISO 81060-2 : 2018 in adults, adolescents or children population for both SBP and DBP. CONCLUSION: The noninvasive blood pressure monitoring function of the EDAN elite V5 patient monitor passed all the requirements of ISO 81060-2:2018 and can be recommended for clinical use in adults, adolescents, or children.


Asunto(s)
Determinación de la Presión Sanguínea , Humanos , Femenino , Masculino , Adulto , Adolescente , Niño , Persona de Mediana Edad , Determinación de la Presión Sanguínea/instrumentación , Determinación de la Presión Sanguínea/normas , Anciano , Monitores de Presión Sanguínea/normas , Presión Sanguínea
15.
Blood Press Monit ; 29(2): 103-106, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193382

RESUMEN

OBJECTIVE: To validate the ANDON KD-595 automated upper-arm blood pressure monitor for clinical use and self-measurement blood pressure measurement according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard. METHODS: Same left-arm blood pressure was sequentially measured in 90 qualified adult participants and compared with a standard mercury sphygmomanometer. A total of 270 comparison pairs were obtained and analyzed according to the universal standard. RESULTS: For the validation Criterion 1 of the universal standard, the mean ± SD of the differences between the test device and reference blood pressure readings was 0.96 ±â€…5.35 and 0.82 ±â€…5.08 mmHg for SBP and DBP, respectively. For Criterion 2, the SDs of the averaged blood pressure differences between the test device and reference blood pressure per subject were 4.84 and 4.64 mmHg (with maximum allowed SDs of 6.87 and 6.89 mmHg) for SBP and DBP, respectively. CONCLUSION: The ANDON KD-595 automated upper-arm blood pressure monitor passed all the validation requirements according to the AAMI/ESH/ISO Universal Standard and can be recommended for clinical use and self-measurement blood pressure measurement in the general population.


Asunto(s)
Monitores de Presión Sanguínea , Hipertensión , Adulto , Humanos , Presión Sanguínea , Determinación de la Presión Sanguínea , Hipertensión/diagnóstico , Esfigmomanometros
16.
Blood Press Monit ; 29(3): 149-155, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38193368

RESUMEN

To evaluate the accuracy of the DBP-1333b upper-arm blood pressure (BP) measuring device in the adult population according to the AAMI/ESH/ISO universal standard (ISO 81060-2:2018+Amd.1:2020). Subjects were recruited in the adult population. The test device was an arm-type electronic sphygmomanometer (DBP-1333b) and the reference device was a desktop sphygmomanometer (XJ11D). Using the BP data measured by the desktop sphygmomanometer as reference BP, the accuracy of the non-invasive BP module of the test device was evaluated to determine whether it met the requirements. Data from 90 individuals were analysed. According to Criterion 1, the mean difference of SBP between the test and reference device was 0.19 mmHg and the SD was 7.45 mmHg. The mean difference of DBP was -0.59 mmHg and the SD was 6.47 mmHg. The mean difference of both SBP and DBP was less than 5 mmHg, and the SD was less than 8 mmHg, which met the requirements. According to Criterion 2, SD of SBP was 5.79 mmHg, which was less than 6.95 mmHg and met the requirements. The SD of DBP was 5.58 mmHg, which was less than 6.93 mmHg and met the requirements. It was concluded that the DBP-1333b complies with the AAMI/ESH/ISO universal standard (ISO 81060-2:2018+Amd.1:2020) and can be recommended for use by the adults.


Asunto(s)
Monitores de Presión Sanguínea , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Brazo/irrigación sanguínea , Presión Sanguínea , Determinación de la Presión Sanguínea/instrumentación , Monitores de Presión Sanguínea/normas , Esfigmomanometros/normas
17.
Blood Press Monit ; 29(1): 35-40, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37661734

RESUMEN

To evaluate associations between home blood pressure monitoring (HBPM) and blood pressure (BP) in vulnerable adults during the COVID-19 pandemic, when access to in-person care was restricted. A retrospective cohort study was conducted in adults with hypertension or elevated BP given a home BP monitor vs. usual care. Change in BP from baseline to follow-up was compared between groups, controlling for potential confounders. Subgroup analyses of BP outcomes were also assessed in patients age >50 years. There was no difference in SBP reduction between n = 82 HBPM patients (-11.7/-2.9 mmHg) and n = 280 usual care patients (-12.5/-5.8 mmHg; P > 0.05). Results were similar in multivariable analysis controlling for potential confounders [coefficient 0.44, 95% confidence interval (CI) -3.98 to 4.87]. However, in the subgroup of patients aged>50 years, there was a significant association between SBP reduction and HBPM in the multivariable analyses (coefficient -7.2, 95% CI -13.8 to -0.62, P = 0.032). HBPM use was not associated with BP reduction in vulnerable adults overall during high telehealth use. An association between SBP reduction and HBPM was observed in those aged>50 years. Targeting limited HBPM resources to those aged >50 years old may have the most impact on BP.


Asunto(s)
Monitores de Presión Sanguínea , Hipertensión , Adulto , Humanos , Persona de Mediana Edad , Presión Sanguínea , Estudios Retrospectivos , Pandemias , Monitoreo Ambulatorio de la Presión Arterial/métodos
18.
J Hum Hypertens ; 38(1): 45-51, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37620413

RESUMEN

An oscillometric waveform (OMW) envelope-based blood pressure (BP) monitoring device is widely used to monitor blood pressure and prevent hypertension and adverse cardiovascular events. At present, all primary care physicians and clinicians widely recommend oscillometric-based BP devices. The consumer selects the device based on their own decision, without knowing whether the device is validated or not, resulting in over- or under-treatment of hypertension. It is imperative that each device must comply with international protocols. In this study, we have investigated the accuracy of inflation and deflation-based oscillometric BP monitoring devices in the case of sinus rhythm (SR). Since different health conditions of the patient affect the oscillometric waveform, which can affect the device's accuracy, in such cases, many BP monitors are skeptical of succeeding in the norms of international protocols. Therefore, this study also aims to calculate the accuracy of these devices in various health conditions and measure the effect of pulse volume, arrhythmia, and respiratory artifact on it using a non-invasive blood pressure (NIBP) simulator. We found that the oscillometric BP devices failed to measure the correct blood pressure in several clinical conditions.


Asunto(s)
Artefactos , Hipertensión , Humanos , Presión Sanguínea/fisiología , Determinación de la Presión Sanguínea/métodos , Arritmias Cardíacas , Monitores de Presión Sanguínea
19.
Blood Press Monit ; 29(1): 45-54, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37702590

RESUMEN

Hypertension affects approximately 100 million U.S. adults and is the leading single contributing risk factor to all-cause mortality. Accurate blood pressure (BP) measurement is essential in the treatment of BP, and a number of devices exist for monitoring. Recently, a new watch-type design was released, the Omron HeartGuide (BP8000), with claims to provide clinically accurate BP measurement while also tracking activity and sleep similar to smart watches. The aim of this research was done in two studies: (1) evaluation of the HeartGuide device for measurement of resting BP and heart rate (HR); and (2) assessment of the HeartGuide for BP, HR, step-counting and sleep monitoring during activities of daily living. Study 1 compared the Omron HeartGuide to the previously validated Welch Allyn ProBP 3400 following a modified version of the Universal Standard for validation of BP measuring devices set by the AAMI/ESH/ISO. While resting HR measured by the HeartGuide was similar to Welch Allyn measures, both systolic and diastolic BP were significantly lower ( P ≤0.001), with differences of 10.4 (11.1) and 3.2 (10.0) mmHg, respectively. Study 2 compared HeartGuide measures to Welch Allyn measures for BP, HR, steps and sleep during various body positions (supine, seated, standing), physiological stressors (cold pressor test, lower body submersion, exercise), and free-living. The HeartGuide significantly underestimated BP though provided accurate HR during most conditions. It also significantly underestimated steps, but reported sleep measures similar to those subjectively reported. Based on the significant differences between the HeartGuide and Welch Allyn, our data indicate the HeartGuide is not a suitable replacement for existing BP monitors.


Asunto(s)
Monitores de Presión Sanguínea , Hipertensión , Adulto , Humanos , Presión Sanguínea/fisiología , Actividades Cotidianas , Determinación de la Presión Sanguínea , Esfigmomanometros , Hipertensión/diagnóstico
20.
Blood Press Monit ; 29(1): 41-44, 2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-37702596

RESUMEN

OBJECTIVE: To validate the iHealth Track KN-550BT oscillometric upper-arm blood pressure monitor in general population according to the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018+AMD1:2020). METHODS: Participants were recruited and the same left-arm sequential method was used for blood pressure measurement according to the ISO 81060-2:2018+AMD1:2020. The validation results were assessed following the protocol and the Bland-Altman scatterplot was used to show the difference between the test device and reference results. RESULTS: A total of 89 qualified participants were included in the final analysis. For the validation Criterion 1, the mean ± SD of the differences between the test device and reference readings was -1.22 ±â€…5.76 mmHg and -0.08 ±â€…4.40 mmHg for systolic and diastolic blood pressure, respectively. For Criterion 2, the mean ± SD of the differences between the test device and reference readings per participant was -1.22 ±â€…5.06 mmHg and -0.08 ±â€…3.84 mmHg for systolic and diastolic blood pressure, respectively. CONCLUSION: The iHealth Track KN-550BT upper-arm blood pressure monitor passed all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018+AMD1:2020) and can be recommended for clinical use and self-measurement in general population.


Asunto(s)
Monitores de Presión Sanguínea , Hipertensión , Humanos , Presión Sanguínea , Determinación de la Presión Sanguínea , Sístole , Adenosilmetionina Descarboxilasa