Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.095
Filtrar
1.
Anal Biochem ; 695: 115640, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-39142532

RESUMEN

The development of integrated analytical devices is crucial for advancing next-generation point-of-care platforms. Herein, we describe a facile synthesis of a strongly catalytic and durable Nitrogen-doped graphene oxide decorated platinum cobalt (NGO-PtCo) nanocomposite that is conjugated with target-specific DNA aptamer (i-e. MUC1) and grown on carbon fiber. Benefitting from the combined features of the high electrochemical surface area of N-doped GO, high capacitance and stabilization by Co, and high kinetic performance by Pt, a robust, multifunctional, and flexible nanotransducer surface was created. The designed platform was applied for the specific detection of a blood-based oncomarker, CA15-3. The electrochemical characterization proved that nanosurface provides a highly conductive and proficient immobilization support with a strong bio-affinity towards MUC1 aptamer. The specific interaction between CA15-3 and the aptamer alters the surface properties of the aptasensor and the electroactive signal probe generated a remarkable increase in signal intensity. The sensor exhibited a wide dynamic range of 5.0 × 10-2 -200 U mL-1, a low limit of detection (LOD) of 4.1 × 10-2 U mL-1, and good reproducibility. The analysis of spiked serum samples revealed outstanding recoveries of up to 100.03 %, by the proposed aptasensor. The aptasensor design opens new revelations in the reliable detection of tumor biomarkers for timely cancer diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Fibra de Carbono , Cobalto , Técnicas Electroquímicas , Grafito , Mucina-1 , Nanocompuestos , Platino (Metal) , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Grafito/química , Humanos , Mucina-1/sangre , Mucina-1/análisis , Cobalto/química , Nanocompuestos/química , Platino (Metal)/química , Técnicas Biosensibles/métodos , Fibra de Carbono/química , Límite de Detección
2.
Analyst ; 149(19): 4908-4914, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-39119745

RESUMEN

While it is recognized that early diagnosis of cancer-related biomarkers can become an effective avenue for timely treatment and successfully improve patient survival, it remains challenging to get accurate inspection results. Currently, most reported cancer biomarker sensing methods are focused on the quantitative detection of a single type of biomarker, which makes accurate medical diagnostics difficult. In this work, we constructed a DNA walker nanomachine aptasensor based on gold nanoparticles for the simultaneous sensing of dual cancer biomarkers. The aptamers, labelled with a fluorophore, hybridized with complementary strands on the gold nanoparticle surface, serve as a walking track. Target analytes bind to their specific aptamers, leading to the dissociation of the unstable double-strand spherical nucleic acid. Exonuclease I (Exo I) selectively digested the aptamers bound with the target analytes, then the released targets go back to the next apamers on the gold nanopareticles surface for walking. The use of spherical nucleic acid probes improved the sensitivity of analyte detection. Exo I provided a driving power for target recycling and considerably improved the sensitivity of the aptasensor as well. The DNA walker nanomachine aptasensor was successfully applied for the detection of carcinoembryonic antigen (CEA) in the range of 0.167 to 3.34 ng mL-1, and mucin-1 (MUC-1) in the same range. Moreover, we used the two aptamers to construct the DNA walker nanomachine and achieved the simultaneous detection of CEA and MUC-1, thus having great potential for biomolecular logic gate construction and early disease diagnosis.


Asunto(s)
Aptámeros de Nucleótidos , Biomarcadores de Tumor , Técnicas Biosensibles , Antígeno Carcinoembrionario , Oro , Nanopartículas del Metal , Mucina-1 , Aptámeros de Nucleótidos/química , Humanos , Oro/química , Biomarcadores de Tumor/análisis , Nanopartículas del Metal/química , Mucina-1/análisis , Técnicas Biosensibles/métodos , Antígeno Carcinoembrionario/análisis , Antígeno Carcinoembrionario/sangre , Límite de Detección , Exodesoxirribonucleasas/química , Exodesoxirribonucleasas/metabolismo , ADN/química , Hibridación de Ácido Nucleico
3.
Am J Dermatopathol ; 46(9): 597-600, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-39150182

RESUMEN

ABSTRACT: Superficial anaplastic lymphoma kinase (ALK)-rearranged myxoid spindle cell neoplasm (SAMS) is a recently described entity which coexpresses ALK, CD34, and commonly S100. These neoplasms are characterized morphologically by concentric spindle cell whorls and cords and are commonly set in an abundant myxoid to myxocollagenous stroma, thus mimicking perineurioma or hybrid nerve sheath tumor. EMA immunostain has been reported to be negative in SAMS which helps in excluding the latter entities. Herein, we report the first EMA-positive SAMS of the right leg in a 37-year-old female patient masquerading as perineurioma/hybrid nerve sheath tumor. The tumor morphologically was comprised of spindle cells arranged in loose whorls and short fascicles set in myxoid to collagenous stroma and coexpressed CD34 and EMA, reminiscent of perineurioma. S100 showed focal staining. ALK immunostain was subsequently performed and was positive. ALK gene rearrangement was identified by fluorescence in situ hybridization break-apart assay and was further confirmed by next-generation sequencing-based RNA sequencing demonstrating FLNA::ALK fusion, thus supporting the diagnosis of SAMS. In conclusion, EMA can be expressed in SAMS, thus posing as a diagnostic pitfall. ALK immunostain and molecular studies are essential for confirming the diagnosis of SAMS and excluding potential mimickers, particularly perineurioma or hybrid nerve sheath tumor.


Asunto(s)
Quinasa de Linfoma Anaplásico , Biomarcadores de Tumor , Reordenamiento Génico , Neoplasias de la Vaina del Nervio , Humanos , Femenino , Quinasa de Linfoma Anaplásico/genética , Adulto , Neoplasias de la Vaina del Nervio/genética , Neoplasias de la Vaina del Nervio/patología , Neoplasias de la Vaina del Nervio/diagnóstico , Diagnóstico Diferencial , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/análisis , Mucina-1/análisis , Neoplasias de los Tejidos Blandos/genética , Neoplasias de los Tejidos Blandos/patología , Neoplasias de los Tejidos Blandos/diagnóstico , Inmunohistoquímica
4.
BMC Pulm Med ; 24(1): 404, 2024 Aug 22.
Artículo en Inglés | MEDLINE | ID: mdl-39174992

RESUMEN

BACKGROUND: The serum markers Krebs von den Lungen-6 (KL-6), surfactant protein A (SP-A), and surfactant protein D (SP-D) have been used for the diagnosis, differential diagnosis, and prognosis prediction of interstitial pneumonia. However, the significance of measuring the serum and bronchoalveolar lavage fluid (BALF) KL-6, SP-D, and SP-A levels in predicting the prognosis of chronic fibrosing interstitial pneumonia (CFIP), idiopathic pulmonary fibrosis, and idiopathic nonspecific interstitial pneumonia remains unclear. We aimed to clarify the significance of measuring the serum and BALF KL-6, SP-A, and SP-D levels in predicting the prognosis of patients with CFIP. METHODS: Among 173 patients who were diagnosed with CFIP between September 2008 and February 2021, 39 who underwent bronchoalveolar lavage were included in this study. Among these, patients experiencing an annual decrease in forced vital capacity (FVC) of ≥10% or those facing challenges in undergoing follow-up pulmonary function tests owing to significant deterioration in pulmonary function were categorized as the rapidly progress group. Conversely, individuals with an annual decrease in the FVC of <10% were classified into the slowly progress group. The serum and BALF KL-6, SP-D, and SP-A levels, as well as BALF/serum SP-D and SP-A ratios were compared between the two groups. RESULTS: Among the patients with CFIP, the BALF SP-D level (p=0.0111), BALF SP-A level (p<0.0010), BALF/serum SP-D ratio (p=0.0051), and BALF/serum SP-A ratio (p<0.0010) were significantly lower in the rapidly than in the slowly progress group (p<0.0010). The receiver operating characteristics analysis results demonstrated excellent performance for diagnosing patients with CFIP, with the BALF SP-D level (area under the curve [AUC], 0.7424), BALF SP-A level (AUC, 0.8842), BALF/serum SP-D ratio (AUC, 0.7673), and BALF/serum SP-A ratio (AUC, 0.8556). Moreover, the BALF SP-A level showed a notably superior CFIP diagnostic capability. Survival analysis using the Kaplan-Meier method revealed that patients with a BALF SP-A level of <1500 ng/mL and BALF/serum SP-A ratio of <15.0 had poor prognoses. CONCLUSIONS: Our results suggest that BALF SP-A measurement may be useful for predicting the prognosis in patients with CFIP.


Asunto(s)
Biomarcadores , Líquido del Lavado Bronquioalveolar , Mucina-1 , Proteína A Asociada a Surfactante Pulmonar , Proteína D Asociada a Surfactante Pulmonar , Humanos , Proteína D Asociada a Surfactante Pulmonar/sangre , Proteína D Asociada a Surfactante Pulmonar/metabolismo , Líquido del Lavado Bronquioalveolar/química , Mucina-1/sangre , Mucina-1/análisis , Femenino , Masculino , Estudios Retrospectivos , Proteína A Asociada a Surfactante Pulmonar/sangre , Proteína A Asociada a Surfactante Pulmonar/metabolismo , Proteína A Asociada a Surfactante Pulmonar/análisis , Anciano , Persona de Mediana Edad , Pronóstico , Biomarcadores/sangre , Biomarcadores/análisis , Fibrosis Pulmonar Idiopática/sangre , Fibrosis Pulmonar Idiopática/diagnóstico , Fibrosis Pulmonar Idiopática/metabolismo , Enfermedades Pulmonares Intersticiales/sangre , Enfermedades Pulmonares Intersticiales/diagnóstico , Enfermedades Pulmonares Intersticiales/metabolismo , Curva ROC , Capacidad Vital , Enfermedad Crónica
5.
Talanta ; 279: 126665, 2024 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-39116728

RESUMEN

Mucin 1 (MUC1) is frequently overexpressed in various cancers and is essential for early cancer detection. Current methods to detect MUC1 are expensive, time-consuming, and require skilled personnel. Therefore, developing a simple, sensitive, highly selective MUC1 detection sensor is necessary. In this study, we proposed a novel "signal-on-off" strategy that, in the presence of MUC1, synergistically integrates catalytic hairpin assembly (CHA) with DNA tetrahedron (Td)-based nonlinear hybridization chain reaction (HCR) to enhance the immobilization of electrochemically active methylene blue (MB) on magnetic nanoparticles (MNP), marking the MB signal "on". Concurrently, the activation of CRISPR-Cas12a by isothermal amplification products triggers the cleavage of single-stranded DNA (ssDNA) at the electrode surface, resulting in a reduction of MgAl-LDH@Fc-AuFe-MIL-101 (containing ferrocene, Fc) on the electrode, presenting the "signal-off" state. Both MB and MgAl-LDH@Fc-AuFe-MIL-101 electrochemical signals were measured and analyzed. Assay parameters were optimized, and sensitivity, stability, and linear range were assessed. Across a concentration spectrum of MUC1 spanning from 10 fg/mL to 100 ng/mL, the MB and MgAl-LDH@Fc-AuFe-MIL-101 signals were calibrated with each other, demonstrating a "signal-on-off" dual electrochemical signaling pattern. This allows for the precise and quantitative detection of MUC1 in clinical samples, offering significant potential for medical diagnosis.


Asunto(s)
Técnicas Biosensibles , Sistemas CRISPR-Cas , Técnicas Electroquímicas , Mucina-1 , Hibridación de Ácido Nucleico , Mucina-1/análisis , Mucina-1/genética , Técnicas Electroquímicas/métodos , Humanos , Técnicas Biosensibles/métodos , Sistemas CRISPR-Cas/genética , Azul de Metileno/química , Nanopartículas de Magnetita/química , ADN de Cadena Simple/química , ADN de Cadena Simple/genética , Electrodos , Límite de Detección , Oro/química
6.
Anal Chem ; 96(31): 12767-12775, 2024 08 06.
Artículo en Inglés | MEDLINE | ID: mdl-39044392

RESUMEN

Bacteria inherently possess the capability of quorum sensing in response to the environment. In this work, we have proposed a strategy to confer bacteria with the ability to recognize targets with quorum-sensing behavior. Meanwhile, we have successfully achieved artificial control over the target-triggered aggregation of Escherichia coli (E. coli) by modifying the bacteria surface in a new way. Furthermore, by making use of green fluorescent protein (GFP) expressed by E. coli as the output signal, the aggregation of modified E. coli can be observed with the naked eye. Therefore, via the detection of the target, MUC1, an ovarian cancer biomarker, a simple and conveniently operated method to diagnose ovarian cancer is developed in this work. Experimental results show that the developed low-background and enzyme-free amplification method enables the highly sensitive detection of MUC1, achieving a remarkable limit of detection (LOD) of 5.47 fM and a linear detection range spanning from 1 pM to 50 nM and 50 nM to 100 nM, respectively. Clinical samples from healthy donors and patients can give distant assay results, showing great potential for clinical applications of this method.


Asunto(s)
Escherichia coli , Mucina-1 , Neoplasias Ováricas , Neoplasias Ováricas/diagnóstico , Escherichia coli/aislamiento & purificación , Humanos , Femenino , Mucina-1/análisis , Mucina-1/metabolismo , Proteínas Fluorescentes Verdes/metabolismo , Proteínas Fluorescentes Verdes/genética , Límite de Detección , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/metabolismo , Percepción de Quorum , Técnicas Biosensibles/métodos
7.
Anal Bioanal Chem ; 416(23): 5071-5088, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39031228

RESUMEN

This study developed an innovative biosensor strategy for the sensitive and selective detection of canine mammary tumor biomarkers, cancer antigen 15-3 (CA 15-3) and mucin 1 (MUC-1), integrating green silver nanoparticles (GAgNPs) with machine learning (ML) algorithms to achieve high diagnostic accuracy and potential for noninvasive early detection. The GAgNPs-enhanced electrochemical biosensor demonstrated selective detection of CA 15-3 in serum and MUC-1 in tissue homogenates, with limits of detection (LODs) of 0.07 and 0.11 U mL-1, respectively. The nanoscale dimensions of the GAgNPs endowed them with electrochemically active surface areas, facilitating sensitive biomarker detection. Experimental studies targeted CA 15-3 and MUC-1 biomarkers in clinical samples, and the biosensor exhibited ease of use and good selectivity. Furthermore, ML algorithms were employed to analyze the electrochemical data and predict biomarker concentrations, enhancing the diagnostic accuracy. The Random Forest algorithm achieved 98% accuracy in tumor presence prediction, while an Artificial Neural Network attained 76% accuracy in CA 15-3-based tumor grade classification. The integration of ML techniques with the GAgNPs-based biosensor offers a promising approach for noninvasive, accurate, and early detection of canine mammary tumors, potentially revolutionizing veterinary diagnostics. This multilayered strategy, combining eco-friendly nanomaterials, electrochemical sensing, and ML algorithms, holds significant potential for advancing both biomedical research and clinical practice in the field of canine mammary tumor diagnostics.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Técnicas Electroquímicas , Aprendizaje Automático , Neoplasias Mamarias Animales , Nanopartículas del Metal , Plata , Animales , Perros , Plata/química , Nanopartículas del Metal/química , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/análisis , Neoplasias Mamarias Animales/diagnóstico , Neoplasias Mamarias Animales/sangre , Técnicas Electroquímicas/métodos , Femenino , Técnicas Biosensibles/métodos , Mucina-1/sangre , Mucina-1/análisis , Enfermedades de los Perros/diagnóstico , Enfermedades de los Perros/sangre , Límite de Detección
8.
Dermatol Online J ; 30(2)2024 Apr 15.
Artículo en Inglés | MEDLINE | ID: mdl-38959917

RESUMEN

Squamoid eccrine ductal carcinoma (SEDC) is a cutaneous adnexal malignancy that is histologically challenging to distinguish from squamous cell carcinoma. We report three cases of this rare entity and review the present literature regarding clinical, histological, and immunohistochemical features. Patients presented with a single nodule or plaque lesion on their back and temple. The shave biopsies for Patient A and C were interpreted as SEDC. Patient B's initial shave biopsy was interpreted as probable surface of squamous cell carcinoma, and subsequent excision revealed SEDC. Ductal differentiation was confirmed by positive expression of epithelial membrane antigen and carcinoembryonic antigen immunostains in all three patients. Review of the 67 previously reported cases emphasizes the importance of diagnosing SEDC accurately and promptly given its potential for distant metastasis and mortality. Perineural or lymphatic invasion is associated with higher rate of recurrence or metastasis. There should be high pathologic suspicion for SEDC in an elderly patient presenting with a palpable lesion, even if located outside of the head and neck area, particularly when there is suggestion of ductal differentiation in a sample of a squamous neoplasm.


Asunto(s)
Carcinoma de Células Escamosas , Glándulas Ecrinas , Neoplasias de las Glándulas Sudoríparas , Humanos , Antígeno Carcinoembrionario/análisis , Antígeno Carcinoembrionario/metabolismo , Carcinoma Ductal/patología , Carcinoma de Células Escamosas/patología , Carcinoma de Células Escamosas/diagnóstico , Diagnóstico Diferencial , Glándulas Ecrinas/patología , Inmunohistoquímica , Mucina-1/análisis , Mucina-1/metabolismo , Neoplasias Cutáneas/patología , Neoplasias Cutáneas/diagnóstico , Neoplasias de las Glándulas Sudoríparas/patología , Anciano
9.
Anal Chim Acta ; 1312: 342762, 2024 Jul 11.
Artículo en Inglés | MEDLINE | ID: mdl-38834277

RESUMEN

Mucin1 (MUC1) is an extensively glycosylated transmembrane protein that is widely distributed and overexpressed on the surface of cancer cells, playing an important role in tumor occurrence and metastasis. Therefore, highly sensitive detection of MUC1 is of great significance for early diagnosis, treatment monitoring, and prognosis of cancer. Here, an ultra-sensitive photoelectrochemical (PEC) sensing platform was developed based on an aptamer amplification strategy for highly selective and sensitive detection of MUC1 overexpressed in serum and on cancer cell surfaces. The sensing platform utilized copper phthalocyanine to fabricate porous organic polymers (CuPc POPs), and was effectively integrated with g-C3N4/MXene to form a ternary heterojunction material (g-C3N4/MXene/CuPc POPs). This material effectively improved electron transfer capability, significantly enhanced light utilization, and greatly enhanced photoelectric conversion efficiency, resulting in a dramatic increase in photocurrent response. MUC1 aptamer 1 was immobilized on a chitosan-modified photoelectrode for the selective capture of MUC1 or MCF-7 cancer cells. When the target substance was present, MUC1 aptamer 2 labeled with methylene blue (MB) was specifically adsorbed on the electrode surface, leading to enhanced photocurrent. The concentration of MUC1 directly correlated with the number of MB molecules attracted to the electrode surface, establishing a linear relationship between photocurrent intensity and MUC1 concentration. The PEC biosensor exhibited excellent sensitivity for MUC1 detection with a wide detection range from 1 × 10-7 to 10 ng/mL and a detection limit of 8.1 ag/mL. The detection range for MCF-7 cells was from 2 × 101 to 2 × 106 cells/mL, with the capability for detecting single MCF-7 cells. The aptamer amplification strategy significantly enhanced PEC performance, and open up a promising platform to establish high selectivity, stability, and ultrasensitive analytical techniques.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Electroquímicas , Mucina-1 , Polímeros , Mucina-1/análisis , Humanos , Aptámeros de Nucleótidos/química , Técnicas Electroquímicas/métodos , Células MCF-7 , Porosidad , Polímeros/química , Límite de Detección , Técnicas Biosensibles/métodos , Indoles/química , Procesos Fotoquímicos , Compuestos Organometálicos/química
10.
Biosens Bioelectron ; 260: 116425, 2024 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-38824703

RESUMEN

Cancer antigen 15-3 (CA 15-3) is a crucial marker used in the diagnosis and monitoring of breast cancer (BC). The demand for early and precise cancer detection has grown, making the creation of biosensors that are highly sensitive and specific essential. This review paper provides a thorough examination of the progress made in optical and electrochemical biosensors for detecting the cancer biomarker CA 15-3. We focus on explaining their fundamental principles, sensitivity, specificity, and potential for point-of-care applications. The performance attributes of these biosensors are assessed by considering their limits of detection, reaction times, and operational stability, while also making comparisons to conventional methods of CA 15-3 detection. In addition, we explore the incorporation of nanomaterials and innovative transducer components to improve the performance of biosensors. This paper conducts a thorough examination of recent studies to identify the existing obstacles. It also suggests potential areas for future research in this fast progressing field.The paper provides insights into their advancement and utilization to enhance patient outcomes. Both categories of biosensors provide significant promise for the detection of CA 15-3 and offer distinct advantages compared to conventional analytical approaches.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Neoplasias de la Mama , Técnicas Electroquímicas , Mucina-1 , Humanos , Neoplasias de la Mama/diagnóstico , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Femenino , Técnicas Electroquímicas/métodos , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/sangre , Mucina-1/análisis
11.
Biosens Bioelectron ; 261: 116493, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38901393

RESUMEN

Although circulating tumor cells (CTCs) have demonstrated considerable importance in liquid biopsy, their detection is limited by low concentrations and complex sample components. Herein, we developed a homogeneous, simple, and high-sensitivity strategy targeting breast cancer cells. This method was based on a non-immunological stepwise centrifugation preprocessing approach to isolate CTCs from whole blood. Precise quantification is achieved through the specific binding of aptamers to the overexpressed mucin 1 (MUC1) and human epidermal growth factor receptor 2 (HER2) proteins of breast cancer cells. Subsequently, DNAzyme cleavage and parallel catalytic hairpin assembly (CHA) reactions on the cholesterol-stacking DNA machine were initiated, which opened the hairpin structures T-Hg2+-T and C-Ag+-C, enabling multiple amplifications. This leads to the fluorescence signal reduction from Hg2+-specific carbon dots (CDs) and CdTe quantum dots (QDs) by released ions. This strategy demonstrated a detection performance with a limit of detection (LOD) of 3 cells/mL and a linear range of 5-100 cells/mL. 42 clinical samples have been validated, confirming their consistency with clinical imaging, pathology findings and the folate receptor (FR)-PCR kit results, exhibiting desirable specificity of 100% and sensitivity of 80.6%. These results highlight the promising applicability of our method for diagnosing and monitoring breast cancer.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama , Colesterol , ADN Catalítico , Células Neoplásicas Circulantes , Humanos , Femenino , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Neoplasias de la Mama/sangre , Técnicas Biosensibles/métodos , ADN Catalítico/química , Biopsia Líquida/métodos , Células Neoplásicas Circulantes/patología , Colesterol/sangre , Colesterol/análisis , Límite de Detección , Puntos Cuánticos/química , Receptor ErbB-2/análisis , Mucina-1/análisis , Mucina-1/sangre , Aptámeros de Nucleótidos/química , Línea Celular Tumoral , Telurio/química , Compuestos de Cadmio/química
12.
Talanta ; 277: 126302, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38830277

RESUMEN

A label-free optical sandwich immunoassay sensor, utilizing weak value amplification and total internal reflection, was devised for real-time, high-sensitivity analysis and detection of low-concentration targets. 3D printed channels and sodium chloride solution were employed to ensure reproducibility, reliability, and stability of the measurements for calibration. The sandwich structure demonstrated enhanced responsiveness in the proposed optical biosensor through a comparative analysis of the direct assay and sandwich assay for detecting alpha-fetoprotein (AFP) at the same concentration. By optimizing the binding sequences of the coating antibody, target, and detection antibody in the sandwich method, a more suitable sandwich sensing approach based on weak value amplification was achieved. With this approach, the limit of detection (LOD) of 6.29 ng/mL (pM level) for AFP in PBS solution was achieved. AFP testing and regeneration experiments in human serum have proved the feasibility of our methods in detecting complex samples and the reusability of sensing chips. Additionally, the method demonstrated excellent selectivity for unpaired antigens. The efficacy of this methodology was evaluated by simultaneously detecting AFP, carcinoembryonic antigen (CEA), and CA15-3 on a singular sensor chip. In conclusion, the label-free sandwich immunoassay sensing scheme holds promise for advancing the proposed optical sensors based on weak value amplification in early diagnosis and prevention applications. Compared to other biomarker detection methods, it will be easier to promote in practical applications.


Asunto(s)
Técnicas Biosensibles , Antígeno Carcinoembrionario , Límite de Detección , alfa-Fetoproteínas , Técnicas Biosensibles/métodos , alfa-Fetoproteínas/análisis , Humanos , Antígeno Carcinoembrionario/sangre , Antígeno Carcinoembrionario/análisis , Inmunoensayo/métodos , Mucina-1/sangre , Mucina-1/análisis , Anticuerpos Inmovilizados/inmunología , Anticuerpos Inmovilizados/química
13.
Mikrochim Acta ; 191(7): 370, 2024 06 05.
Artículo en Inglés | MEDLINE | ID: mdl-38837084

RESUMEN

The development of an ultrasensitive and precise measurement of a breast cancer biomarker (cancer antigen 15-3; CA15-3) in complex human serum is essential for the early diagnosis of cancer in groups of healthy populations and the treatment of patients. However, currently available testing technologies suffer from insufficient sensitivity toward CA15-3, which severely limits early large-scale screening of breast cancer patients. We report a versatile electrochemical immunoassay method based on atomically cobalt-dispersed nitrogen-doped carbon (Co-NC)-modified disposable screen-printed carbon electrode (SPCE) with alkaline phosphatase (ALP) and its metabolite, ascorbic acid 2-phosphate (AAP), as the electrochemical labeling and redox signaling unit for sensitive detection of low-abundance CA15-3. During electrochemical detection by differential pulse voltammetry (DPV), it was found that the Co-NC-SPCE electrode did not have a current signal response to the AAP substrate; however, it had an extremely favorable response current to ascorbic acid (AA). Based on the above principle, the target CA15-3-triggered immunoassay enriched ALP-catalyzed AAP produces a large amount of AA, resulting in a significant change in the system current signal, thereby realizing the highly sensitive detection of CA15-3. Under the optimal AAP substrate concentration and ALP catalysis time, the Co-NC-SPCE-based electrochemical immunoassay demonstrated a good DPV current for CA15-3 in the assay interval of 1.0 mU/mL to 10,000 mU/mL, with a calculated limit of detection of 0.38 mU/mL. Since Co-NC-SPCE has an excellent DPV current response to AA and employs split-type scheme, the constructed electrochemical immunoassay has the merits of high preciseness and anti-interference, and its clinical diagnostic results are comparable to those of commercial kits.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama , Carbono , Cobalto , Técnicas Electroquímicas , Mucina-1 , Nitrógeno , Femenino , Humanos , Fosfatasa Alcalina/sangre , Fosfatasa Alcalina/química , Ácido Ascórbico/química , Ácido Ascórbico/sangre , Ácido Ascórbico/análogos & derivados , Biomarcadores de Tumor/sangre , Técnicas Biosensibles/métodos , Neoplasias de la Mama/sangre , Carbono/química , Cobalto/química , Técnicas Electroquímicas/métodos , Electrodos , Inmunoensayo/métodos , Límite de Detección , Mucina-1/análisis , Mucina-1/sangre , Mucina-1/inmunología , Nitrógeno/química
14.
Biosensors (Basel) ; 14(5)2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38785696

RESUMEN

This work presents a novel approach for tailoring molecularly imprinted polymers (MIPs) with a preliminary stage of atom transfer radical polymerization (ATRP), for a more precise definition of the imprinted cavity. A well-defined copolymer of acrylamide and N,N'-methylenebisacrylamide (PAAm-co-PMBAm) was synthesized by ATRP and applied to gold electrodes with the template, followed by a crosslinking reaction. The template was removed from the polymer matrix by enzymatic/chemical action. The surface modifications were monitored via electrochemical impedance spectroscopy (EIS), having the MIP polymer as a non-conducting film designed with affinity sites for CA15-3. The resulting biosensor exhibited a linear response to CA15-3 log concentrations from 0.001 to 100 U/mL in PBS or in diluted fetal bovine serum (1000×) in PBS. Compared to the polyacrylamide (PAAm) MIP from conventional free-radical polymerization, the ATRP-based MIP extended the biosensor's dynamic linear range 10-fold, improving low concentration detection, and enhanced the signal reproducibility across units. The biosensor demonstrated good sensitivity and selectivity. Overall, the work described confirmed that the process of radical polymerization to build an MIP material influences the detection capacity for the target substance and the reproducibility among different biosensor units. Extending this approach to other cancer biomarkers, the methodology presented could open doors to a new generation of MIP-based biosensors for point-of-care disease diagnosis.


Asunto(s)
Técnicas Biosensibles , Polímeros Impresos Molecularmente , Polimerizacion , Humanos , Acrilamidas/química , Resinas Acrílicas/química , Espectroscopía Dieléctrica , Oro/química , Impresión Molecular , Polímeros Impresos Molecularmente/química , Polímeros/química , Reproducibilidad de los Resultados , Mucina-1/análisis , Mucina-1/química
15.
Biosens Bioelectron ; 259: 116382, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38749284

RESUMEN

Small extracellular vesicles (sEVs) reflect the genotype and phenotype of original cells and are biomarkers for early diagnosis and treatment monitoring of tumors. Yet, their small size and low density make them difficult to isolate and detect in body fluid samples. This study proposes a novel acDEP-Exo chip filled with transparent micro-beads, which formed a non-uniform electrical field, and finally achieved rapid, sensitive, and tunable sEVs capture and detection. The method requires only 20-50 µL of sample, achieved a limit of detection (LOD) of 161 particles/µL, and can detect biomarkers within 13 min. We applied the chip to analyze the two markers of sEV's EpCAM and MUC1 in clinical plasma samples from breast cancer (BC) patients and healthy volunteers and found that the combined evaluation of sEV's biomarkers has extremely high sensitivity, specificity and accuracy. The present study introduces an alternative approach to sEVs isolation and detection, has a great potential in real-time sEVs-based liquid biopsy.


Asunto(s)
Biomarcadores de Tumor , Técnicas Biosensibles , Neoplasias de la Mama , Molécula de Adhesión Celular Epitelial , Vesículas Extracelulares , Dispositivos Laboratorio en un Chip , Mucina-1 , Humanos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/sangre , Vesículas Extracelulares/química , Femenino , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Mucina-1/sangre , Mucina-1/análisis , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/aislamiento & purificación , Límite de Detección , Diseño de Equipo , Electroforesis/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Biopsia Líquida/métodos , Biopsia Líquida/instrumentación
16.
Biosens Bioelectron ; 259: 116380, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38754193

RESUMEN

Exosomes, as novel biomarker for liquid biopsy, exhibit huge important potential value for cancer diagnosis. However, various proteins show different expression levels on exosomal membrane, and the absolute concentration of exosomes in clinical samples is easily influenced by a number of factors. Here, we developed a CRISPR/Cas12a and aptamer-chemiluminescence based analysis (CACBA) for the relative abundance determination of tumor-related protein positive exosomes in plasma for breast cancer diagnosis. The total concentration of exosomes was determined through captured CD63 using a CRISPR/Cas12a-based method with the LoD of 8.97 × 103 particles/µl. Meanwhile, EpCAM and MUC1 positive exosomes were quantitatively detected by aptamer-chemiluminescence (ACL) based method with the LoD of 1.45 × 102 and 3.73 × 102 particles/µl, respectively. It showed that the percentages of EpCAM and MUC1 positive exosomes offered an excellent capability to differentiate breast cancer patients and healthy donors. The high sensitivity, strong specificity, outstanding anti-interference capability, and steady recovery rate of this approach offered higher accuracy and robustness than the commercialized method in clinical trial. In addition with good stability, easy preparation and low cost, this method not only provides a new approach to rapid analysis of exosome proteins, it may be quickly extended to the diagnoses of various cancers.


Asunto(s)
Aptámeros de Nucleótidos , Biomarcadores de Tumor , Técnicas Biosensibles , Neoplasias de la Mama , Sistemas CRISPR-Cas , Molécula de Adhesión Celular Epitelial , Exosomas , Mucina-1 , Humanos , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/sangre , Neoplasias de la Mama/genética , Exosomas/química , Exosomas/genética , Femenino , Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Mucina-1/sangre , Mucina-1/genética , Mucina-1/análisis , Biomarcadores de Tumor/sangre , Biomarcadores de Tumor/genética , Molécula de Adhesión Celular Epitelial/genética , Mediciones Luminiscentes/métodos , Tetraspanina 30 , Límite de Detección
17.
ACS Appl Mater Interfaces ; 16(20): 25601-25609, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38727578

RESUMEN

We report an ultrasensitive sandwich-type electrochemical immunosensor to detect the breast cancer biomarker CA 15-3. Amine-functionalized composite of reduced graphene oxide and Fe3O4 nanoparticles (MRGO-NH2) was used as an electrochemical sensing platform material to modify the electrodes. The nanocomposite comprising Pt and Fe3O4 nanoparticles (NPs) anchored on multiwalled carbon nanotubes (Pt-Fe3O4-MWCNTs-NH2) was utilized as a pseudoenzymatic signal-amplifying label. Compared to reduced graphene oxide, the composite MRGO-NH2 platform material demonstrated a higher electrochemical signal. In the Pt-Fe3O4-MWCNTs-NH2 label, multiwalled carbon nanotubes provided the substratum to anchor abundant catalytic Pt and Fe3O4 NPs. The nanocomposites were thoroughly characterized using transmission electron microscopy, Fourier transform infrared spectroscopy, X-ray diffraction, scanning electron microscopy, and X-ray photoelectron spectroscopy. An electroanalytical study and prevalidation of the immunosensor was carried out. The immunosensor exhibited exceptional capabilities in detecting CA 15-3, offering a wider linear range of 0.0005-100 U mL-1 and a lower detection limit of 0.00008 U mL-1. Moreover, the designed immunosensor showed good specificity, reproducibility, and acceptable stability. The sensor was successfully applied to analyze samples from breast cancer patients, yielding reliable results.


Asunto(s)
Biomarcadores de Tumor , Neoplasias de la Mama , Técnicas Electroquímicas , Nanocompuestos , Nanotubos de Carbono , Platino (Metal) , Humanos , Nanotubos de Carbono/química , Neoplasias de la Mama/diagnóstico , Nanocompuestos/química , Técnicas Electroquímicas/métodos , Biomarcadores de Tumor/análisis , Biomarcadores de Tumor/sangre , Femenino , Platino (Metal)/química , Técnicas Biosensibles/métodos , Grafito/química , Aminas/química , Mucina-1/análisis , Mucina-1/sangre , Inmunoensayo/métodos , Límite de Detección
18.
Talanta ; 275: 126191, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38705020

RESUMEN

Mucin 1 is a significant tumor marker, and developing portable and cost-effective methods for its detection is crucial, especially in resource-limited areas. Herein, we developed an innovative approach for mucin 1 detection using a visible multicolor aptasensor. Urease-encapsulated DNA microspheres were used to mediate multicolor change facilitated by the color mixing of the mixed pH indicator, a mixed methyl red and bromocresol green solution. Distinct color changes were exhibited in response to varying mucin 1 concentrations. Notably, the color mixing of the mixed pH indicator was used to display various hues of colors, broadening the range of color variation. And color tonality is much easier to differentiate than color intensity, improving the resolution with naked-eyes. Besides, the variation of color from red to green (a pair of complementary colors) enhanced the color contrast, heightening sensitivity for visual detection. Importantly, the proposed method was successfully applied to detect mucin 1 in real samples, demonstrating a clear differentiation of colors between the samples of healthy individuals and breast cancer patients. The use of a mixed pH indicator as a multichromatic substrate offers the merits of low cost, fast response to pH variation, and plentiful color-evolution. And the incorporation of calcium carbonate microspheres to encapsulate urease ensures stable urease activity and avoids the need for extra urease decoration. The color-mixing dependent strategy opens a new way for multicolor detection of MUC1, characterized by vivid color changes.


Asunto(s)
Aptámeros de Nucleótidos , Técnicas Biosensibles , Color , Mucina-1 , Ureasa , Ureasa/química , Concentración de Iones de Hidrógeno , Mucina-1/análisis , Mucina-1/química , Humanos , Técnicas Biosensibles/métodos , Aptámeros de Nucleótidos/química , Microesferas , Neoplasias de la Mama
19.
J Mater Chem B ; 12(22): 5551-5560, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38747235

RESUMEN

Timely identification of cancers is pivotal in optimizing treatment efficacy and reducing their widespread impact. This study introduces a novel biosensor for the sensitive electrochemical detection of cancer cells overexpressing mucin 1 (MUC1), a well-established model for breast cancer. The sensor substrate comprises gold columnar nanostructures obtained through glancing angle deposition (GLAD) of copper nanostructures, subsequently replaced by gold via a facile galvanic replacement process. Functionalizing these gold nanostructures with aptamers targeting the MUC1 glycoproteins, a prominent cancer biomarker, enables specific recognition of MCF-7 breast cancer cells. The proposed electrochemical sensing platform offers several advantages, including high selectivity, a wide linear range of detection, a low detection limit of 30 cells per mL, and long-term stability, rendering this sensor highly desirable for definitive breast cancer diagnosis.


Asunto(s)
Técnicas Biosensibles , Neoplasias de la Mama , Técnicas Electroquímicas , Oro , Mucina-1 , Humanos , Técnicas Biosensibles/métodos , Oro/química , Células MCF-7 , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Mucina-1/análisis , Mucina-1/metabolismo , Femenino , Nanoestructuras/química , Nanopartículas del Metal/química , Aptámeros de Nucleótidos/química
20.
Anal Chem ; 96(22): 9218-9227, 2024 06 04.
Artículo en Inglés | MEDLINE | ID: mdl-38781682

RESUMEN

In situ monitoring of cell secretions and communications plays a fundamental role in screening of disease diagnostic biomarkers and drugs. Quantitative detection of cell secretions and monitoring of intercellular communication have been separately reported, which often rely on target labeling or complex pretreatment steps, inevitably causing damage to the target. Simultaneous in situ noninvasive detection of cell secretions and monitoring of intercellular communication are challenging and have never been reported. Herein, we smartly developed a portable device for in situ label-free monitoring of cell secretions and communications with fluorescence and ion-transport-based nanochannel electrochemistry. Based on the dual signal mode, a series of nonelectroactive secretions were sensitively and accurately quantified. The detection limits for VEGF, MUC1, and ATP were 3.84 pg/mL, 32.7 pg/mL, and 47.4 fM (3σ/S), which were 1/3.9, 1/1.1, and 1/41 of those of commercial ELISA kits, respectively. More interestingly, under the released secretions, the gradual opening of the nanochannel connected the two cells in the left and right chambers of the device; thus, the secretion mediated intercellular communication can be monitored. The proposed platform may provide a promising tool for understanding the mechanism of intercellular communication and discovering new therapeutic targets.


Asunto(s)
Técnicas Electroquímicas , Humanos , Técnicas Electroquímicas/instrumentación , Adenosina Trifosfato/análisis , Adenosina Trifosfato/metabolismo , Mucina-1/análisis , Mucina-1/metabolismo , Comunicación Celular , Factor A de Crecimiento Endotelial Vascular/análisis , Factor A de Crecimiento Endotelial Vascular/metabolismo , Fluorescencia , Límite de Detección
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...