Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 798
Filtrar
1.
Expert Opin Drug Metab Toxicol ; 20(7): 647-663, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38881199

RESUMEN

INTRODUCTION: Seizures are known potential side effects of nicotine toxicity and have been reported in electronic nicotine delivery systems (ENDS, e-cigarettes) users, with the majority involving youth or young adults. AREAS COVERED: Using chemoinformatic computational models, chemicals (including flavors) documented to be present in ENDS were compared to known neuroactive compounds to predict the blood-brain barrier (BBB) penetration potential, central nervous system (CNS) activity, and their structural similarities. The literature search used PubMed/Google Scholar, through September 2023, to identify individual chemicals in ENDS and neuroactive compounds.The results show that ENDS chemicals in this study contain >60% structural similarity to neuroactive compounds based on chemical fingerprint similarity analyses. The majority of ENDS chemicals we studied were predicted to cross the BBB, with approximately 60% confidence, and were also predicted to have CNS activity; those not predicted to passively diffuse through the BBB may be actively transported through the BBB to elicit CNS impacts, although it is currently unknown. EXPERT OPINION: In lieu of in vitro and in vivo testing, this study screens ENDS chemicals for potential CNS activity and predicts BBB penetration potential using computer-based models, allowing for prioritization for further study and potential early identification of CNS toxicity.


Asunto(s)
Barrera Hematoencefálica , Simulación por Computador , Sistemas Electrónicos de Liberación de Nicotina , Nicotina , Barrera Hematoencefálica/metabolismo , Humanos , Nicotina/administración & dosificación , Nicotina/farmacocinética , Nicotina/efectos adversos , Animales , Adulto Joven , Convulsiones/inducido químicamente , Adolescente , Transporte Biológico , Adulto , Aromatizantes/administración & dosificación , Aromatizantes/efectos adversos
2.
Inhal Toxicol ; 36(6): 378-390, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38909354

RESUMEN

OBJECTIVE: Cigarette smoking can lead to a host of adverse health effects such as lung and heart disease. Increased lung cancer risk is associated with inhalation of carcinogens present in a puff of smoke. These carcinogenic compounds deposit in the lung at different sites and trigger a cascade of events leading to adverse outcomes. Understanding the site-specific deposition of various smoke constituents will inform the study of respiratory diseases from cigarette smoking. We previously developed a deposition model for inhalation of aerosol from electronic nicotine delivery systems. In this study, the model was modified to simulate inhalation of cigarette smoke consisting of soluble and insoluble tar, nicotine, and cigarette-specific constituents that are known or possible human carcinogens. MATERIALS AND METHODS: The deposition model was further modified to account for nicotine protonation and other cigarette-specific physics-based mechanisms that affect smoke deposition. Model predictions showed a total respiratory tract uptake in the lung for formaldehyde (99%), nicotine (80%), and benzo[a]pyrene (60%). RESULTS: The site of deposition and uptake depended primarily on the constituent's saturation vapor pressure. High vapor pressure constituents such as formaldehyde were preferentially absorbed in the oral cavity and proximal lung regions, while low vapor pressure constituents such as benzo[a]pyrene were deposited in the deep lung regions. Model predictions of exhaled droplet size, droplet retention, nicotine retention, and uptake of aldehydes compared favorably with experimental data. CONCLUSION: The deposition model can be integrated into exposure assessments and other studies that evaluate potential adverse health effects from cigarette smoking.


Asunto(s)
Nicotina , Humanos , Nicotina/administración & dosificación , Nicotina/farmacocinética , Modelos Biológicos , Humo/análisis , Humo/efectos adversos , Formaldehído/análisis , Formaldehído/toxicidad , Productos de Tabaco/análisis , Benzo(a)pireno/farmacocinética , Benzo(a)pireno/análisis , Sistema Respiratorio/efectos de los fármacos , Sistema Respiratorio/metabolismo , Pulmón/efectos de los fármacos , Pulmón/metabolismo , Aerosoles , Administración por Inhalación , Exposición por Inhalación/efectos adversos , Fumar Cigarrillos , Sistemas Electrónicos de Liberación de Nicotina
3.
Anal Methods ; 16(24): 3815-3830, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38738307

RESUMEN

Nicotine crosses the blood-brain barrier and interacts with nicotinic acetylcholine receptors, initiating a cascade of neurotransmitter effects with potential therapeutic implications for neurodegenerative conditions such as Alzheimer's and Parkinson's disease. The hippocampus, pivotal for cognitive processes, plays a crucial role in nicotine-mediated cognitive enhancement due to its abundant expression of nicotinic acetylcholine receptors, particularly the α7 subtype, which is heavily implicated in hippocampus-related behavioral functions and dysfunctions. However, the intricate process of nicotine metabolism within the hippocampus remains poorly understood, impeding our comprehension of how nicotine and its metabolites modulate neurotransmitter dynamics. To address this gap, we have developed and validated a novel methodology combining microdialysis with UHPLC-MS/MS, enabling simultaneous detection of 12 neurotransmitters, nicotine, and its seven metabolites within the rat hippocampus. The linearity range of the targeted compounds is satisfactory (R2 > 0.9970), with intra-day and inter-day precision not exceeding 12.7%, and accuracy ranging from -12.4% to 13.7%. Our findings reveal differential pharmacokinetics of nicotine and its metabolites in the α7KO group compared to the control group, characterized by heightened nicotine absorption and slower elimination and distribution in the former. Notably, the pharmacokinetic parameters of cotinine exhibit similarity across both groups. Studies investigating the impact of nicotine on monoamine neurotransmitters have elucidated its capacity to augment the release of dopamine, serotonin, norepinephrine, glutamate, and acetylcholine in the rat hippocampus. This integrated approach facilitates a comprehensive analysis of neurotransmitter alterations within the hippocampal region following nicotine administration, thereby providing robust technical support and scientific rationale for understanding the neurochemical effects of nicotine and its metabolites. Further exploration into the pharmacokinetics and pharmacodynamics of nicotine holds promise for uncovering novel therapeutic avenues in the management of neurodegenerative diseases such as Alzheimer's.


Asunto(s)
Hipocampo , Microdiálisis , Neurotransmisores , Nicotina , Ratas Sprague-Dawley , Espectrometría de Masas en Tándem , Nicotina/farmacocinética , Nicotina/metabolismo , Animales , Hipocampo/metabolismo , Microdiálisis/métodos , Cromatografía Líquida de Alta Presión/métodos , Espectrometría de Masas en Tándem/métodos , Neurotransmisores/metabolismo , Neurotransmisores/análisis , Ratas , Masculino
4.
Nicotine Tob Res ; 26(10): 1313-1321, 2024 Sep 23.
Artículo en Inglés | MEDLINE | ID: mdl-38597729

RESUMEN

INTRODUCTION: Popular "pod-style" e-cigarettes commonly use nicotine salt-based e-liquids that cause less irritation when inhaled and can deliver higher nicotine concentrations than free-base nicotine. This study investigated the pharmacokinetic and pharmacodynamic effects of different nicotine formulations (salt vs. free-base) and concentrations that might influence systemic nicotine absorption and appeal of e-cigarettes. AIMS AND METHODS: In this randomized, double-blind, within-subject crossover study, 20 non-nicotine-naïve participants were switched among three e-liquids (free-base nicotine 20 mg/mL, nicotine salt 20 mg/mL, nicotine salt 40 mg/mL) using a refillable pod system and a standardized vaping protocol (one puff every 30 seconds, 10 puffs total). Serum nicotine concentrations and vital signs were assessed over 180 minutes; direct effects, craving, satisfaction, withdrawal, and respiratory symptoms were measured using questionnaires. CYP2A6 genotypes and the nicotine metabolite ratio were also assessed. RESULTS: Eleven (55%) participants were male and the median age was 23.5 years (range 18-67). All three formulations differed significantly in peak serum nicotine concentration (baseline adjusted Cmax, median (range): 12.0 ng/mL (1.6-27.3), 5.4 ng/mL (1.9-18.7), and 3.0 ng/mL (1.3-8.8) for nicotine salt 40 mg/mL, nicotine salt 20 mg/mL and free-base 20 mg/mL, respectively). All groups reached Cmax 2.0-2.5 minutes (median) after their last puff. Differences in subjective effects were not statistically significant. No serious adverse events were observed. CONCLUSIONS: Free-base 20 mg/mL formulations achieved lower blood nicotine concentrations than nicotine salt 20 mg/mL, while 40 mg/mL nicotine salt yielded concentrations similar to cigarette smoking. The findings can inform regulatory policy regarding e-liquids and their potential use in smoking cessation. IMPLICATIONS: Nicotine salt formulations inhaled by an e-cigarette led to higher nicotine delivery compared to nicotine-free-base formulations with the same nicotine concentration. These findings should be considered in future regulatory discussions. The 40 mg/mL nicotine salt formulation showed similar nicotine delivery as combustible cigarettes, albeit at concentrations over the maximum limit for e-liquids allowed in the European Union. Nicotine delivery resembling combustible cigarettes might be beneficial for smokers willing to quit to adequately alleviate withdrawal symptoms. However, increased nicotine delivery can also pose a public health risk, raising concerns about abuse liability, especially among youth and nonsmokers.


Asunto(s)
Estudios Cruzados , Sistemas Electrónicos de Liberación de Nicotina , Nicotina , Vapeo , Humanos , Masculino , Adulto , Nicotina/farmacocinética , Nicotina/sangre , Nicotina/administración & dosificación , Femenino , Adulto Joven , Método Doble Ciego , Persona de Mediana Edad , Adolescente , Administración por Inhalación , Anciano , Citocromo P-450 CYP2A6
5.
J Aerosol Med Pulm Drug Deliv ; 37(4): 167-170, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38687136

RESUMEN

Background: Recent studies show e-cigarette (EC) users have increased rates of chronic bronchitic symptoms that may be associated with depressed mucociliary clearance (MCC). Little is known about the acute or chronic effects of EC inhalation on in vivo MCC. Methods: In vivo MCC was measured in young adult vapers (n = 5 males, mean age = 21) after controlled inhalation of a radiolabeled (Tc99m sulfur colloid) aerosol. Whole-lung clearance of radiolabeled deposited particles was measured over a 90-minute period for baseline MCC and associated with controlled periodic vaping over the first 60 minutes of MCC measurements. The vaping challenge was administered from a fourth generation box mod EC containing unflavored e-liquid (65% propylene glycol/35% vegetable glycerin, 3 mg/mL freebase nicotine). The challenge was administered at the start of each 10-minute interval of MCC measurements and consisted of 1 puff every 30 seconds for 5 minutes (i.e., 10 puffs for each 10-minute period for a total of 60 puffs during the initial 60 minutes of MCC measurements). Results: Compared with baseline, peripheral lung average clearance (%) over the 90 minutes of MCC measures was enhanced, associated with EC challenge, 12 (±6) versus 24 (±6), respectively (p < 0.05 by Wilcoxon signed-rank test). Conclusions: Acute enhancement of in vivo MCC during EC challenge is contrary to recent studies showing nicotine-associated slowing of ciliary beat and mucus transport at higher nicotine levels than those used here. However, our findings are consistent with an acute increase in fluid volume and mucin secretion to the bronchial airway surface that is likely short lived. Research reported in this publication was supported by the National Institutes of Health R01HL139369 and registered with ClinicalTrials.gov (NCT03700892).


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Pulmón , Depuración Mucociliar , Nicotina , Vapeo , Adolescente , Adulto , Femenino , Humanos , Masculino , Adulto Joven , Administración por Inhalación , Aerosoles , Glicerol/administración & dosificación , Pulmón/metabolismo , Pulmón/fisiopatología , Depuración Mucociliar/efectos de los fármacos , Nicotina/administración & dosificación , Nicotina/farmacocinética , Nicotina/efectos adversos , Propilenglicol/administración & dosificación , Azufre Coloidal Tecnecio Tc 99m/administración & dosificación , Factores de Tiempo , Vapeo/efectos adversos
6.
Sci Rep ; 13(1): 8894, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-37264061

RESUMEN

We report the findings from a randomized, parallel study designed to evaluate nicotine pharmacokinetics (PK) following 10 min of ad libitum use of electronic nicotine delivery system (ENDS) in four flavor variants. Subjects were randomized an investigational product (IP) and blood samples were collected for PK assessments during a test session. Primary endpoints were baseline-adjusted values of maximum plasma nicotine concentration (Cmax) and area under the nicotine concentration-vs-time curve up to 60 min (AUCnic0-60). Baseline-adjusted mean Cmax ranged from 6.53 to 8.21 ng/mL, and mean AUCnic0-60 ranged from 206.87 to 263.52 ng min/mL for all ENDS IPs. Results of geometric mean Cmax and AUCnic0-60 values were within 95% confidence intervals (CI) among the ENDS IP flavor variants tested.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Humanos , Nicotina/farmacocinética , Fumadores
7.
Sci Rep ; 12(1): 22080, 2022 12 21.
Artículo en Inglés | MEDLINE | ID: mdl-36543869

RESUMEN

Abuse liability (AL) of electronic nicotine delivery systems (ENDS) is relevant as the category increases in popularity as a potentially less-harmful alternative to cigarette smoking. AL assessments are important to the FDA in determining if a new product is appropriate for the protection of public health. This paper reports the results for Vuse Solo (G2 cartridge design) compared to high and low AL-comparators evaluated in an open-label, randomized crossover confinement AL study. The confinement design was adapted from previous ambulatory studies of Vuse Solo (G1 cartridge design) and included product familiarization sessions before each four-hour test session in which subjective measures, nicotine pharmacokinetics (PK), and physiological endpoints were assessed following a single 10-min ad libitum product use session. Product liking, intent to use again, suppression of urge to smoke, and nicotine PK were lower after use of Vuse Solo compared to cigarettes and higher after use of Vuse Solo compared to nicotine gum. No significant differences in blood pressure or heart rate were observed between the products pre- to post-product use. These data reinforce previous research and provide the scientific evidence to support regulatory decisions demonstrating that Vuse Solo has an AL profile lower than that of combustible cigarettes but higher than that of nicotine gum and, therefore, may be a suitable replacement for cigarette smoking for some adult smokers.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Chicles de Nicotina , Productos de Tabaco , Nicotina/farmacocinética , Nicotiana
8.
Sci Rep ; 12(1): 14701, 2022 08 29.
Artículo en Inglés | MEDLINE | ID: mdl-36038580

RESUMEN

Tobacco heating products (THPs) have reduced emissions of toxicants compared with cigarette smoke, and as they expose user to lower levels than smoking, have for a role to play in tobacco harm reduction. One key concern of Public Health is that new tobacco and nicotine products should not be more addictive than cigarettes. To assess their abuse liability, we determined nicotine pharmacokinetics and subjective effects of two THPs compared with conventional cigarettes and a nicotine replacement therapy (Nicotine inhaler). In a randomised, controlled, open-label, crossover study healthy adult smokers used a different study product in a 5 min ad libitum use session in each of four study periods. Product liking, overall intent to use again, urge for product and urge to smoke questionnaires were utilised to assess subjective effects. Nicotine uptake was greater for the cigarette (Cmax = 22.7 ng/mL) than for either THP (8.6 and 10.5 ng/mL) and the NRT (2.3 ng/mL). Median Tmax was significantly longer for the NRT (15.03 min) than for the tobacco products (4.05-6.03 min). Product liking and overall intent to use again was highest for the cigarette, and higher for the THPs than the NRT. Urge to smoke was reduced more by the cigarette than by the other three products. Urge to use the THPs was greater than the NRT. These findings suggest that the abuse liability of the THPs lies between that of subjects usual brand cigarettes and the NRT.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Cese del Hábito de Fumar , Productos de Tabaco , Adulto , Estudios Cruzados , Calefacción , Humanos , Nicotina/efectos adversos , Nicotina/farmacocinética , Nicotiana , Productos de Tabaco/efectos adversos , Dispositivos para Dejar de Fumar Tabaco/efectos adversos
9.
Psychopharmacology (Berl) ; 239(3): 977-988, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35184228

RESUMEN

RATIONALE: Electronic nicotine delivery systems and heated tobacco products are noncombustible alternatives for adult smokers. Evidence suggests sufficient nicotine delivery and satisfying effects are necessary to facilitate switching away from smoking; nicotine delivery varies across electronic nicotine delivery systems within limited nicotine concentrations. OBJECTIVES: To assess the nicotine delivery and subjective effects of prototype JUUL2 System in two nicotine concentrations, currently-marketed US JUUL System ("JUUL"), IQOS-brand heated tobacco product, and combustible cigarettes. METHODS: Adult smokers (N = 40) completed a 5-arm cross-over product-use laboratory confinement study. Nicotine pharmacokinetics and subjective effects were assessed following use of: (1) JUUL2 prototype 18 mg/mL nicotine; (2) JUUL2 prototype 40 mg/mL; (3) JUUL 59 mg/mL; (4) IQOS 18 mg/g; and (5) usual brand combustible cigarette, each evaluated during ad libitum (10 min) and controlled (5 min, 10 standardized puffs) use. RESULTS: Nicotine delivery was greatest for combustible cigarettes, followed by JUUL2 prototype 40 mg/mL, IQOS, JUUL2 prototype 18 mg/mL, and JUUL 59 mg/mL. Nicotine delivery from JUUL2 prototype 18 mg/mL was significantly greater than JUUL 59 mg/mL after ad libitum use. JUUL products were significantly more satisfying and effective at reducing craving than IQOS. JUUL2 prototype 40 mg/mL was significantly more aversive than other JUUL products. CONCLUSIONS: Prototype JUUL2 and JUUL 59 mg/mL products were rated higher than IQOS on subjective measures associated with switching away from smoking. The JUUL2 prototype 40 mg/mL produced aversive responses and would require modifications to be a viable product for adult smokers. Nicotine delivery and subjective responses to JUUL2 prototype 18 mg/mL suggest a product based on this prototype may facilitate increased switching among adult smokers.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Adulto , Humanos , Nicotina/farmacocinética , Fumadores , Fumar
10.
Sci Rep ; 12(1): 1091, 2022 01 20.
Artículo en Inglés | MEDLINE | ID: mdl-35058535

RESUMEN

Physiologically based pharmacokinetic (PBPK) modeling can be a useful tool for characterizing nicotine pharmacokinetics (PK) from use of tobacco products. We expand a previously published PBPK model to simulate a nicotine PK profile, following single or multiple use of various tobacco products [cigarettes, smokeless tobacco, and electronic nicotine delivery systems, or a nicotine inhaler (NICOTROL)] The uptake route in the model was designed to allow for three uptake compartments: buccal cavity (BC), upper respiratory tract (URT) (conducting and transitional airways) and lower respiratory tract (alveolar region). Within each region, the model includes product-specific descriptions of the flux of nicotine into plasma, as well as the flux of nicotine from the BC and URT to the gastrointestinal tract. These descriptions are based on regional deposition and diffusion models of nicotine into plasma, which depends on the product type. Regional deposition flux combined with regional differences in physiological parameters (e.g., blood perfusion ratio and tissue thickness) play a key role in the product-specific PK profile of nicotine. The current model describes the slower flux of nicotine into plasma across the BC and URT, as well as the rapid flux known to occur in the alveolar region. Overall, the addition of the BC and respiratory tract compartments to the nicotine model provided simulation results that are comparable to the nicotine time-course plasma concentrations reported from clinical studies for the four product categories simulated.


Asunto(s)
Nicotina/administración & dosificación , Nicotina/farmacocinética , Uso de Tabaco/fisiopatología , Fumar Cigarrillos , Biología Computacional/métodos , Simulación por Computador , Sistemas Electrónicos de Liberación de Nicotina , Humanos , Modelos Biológicos , Productos de Tabaco/efectos adversos , Uso de Tabaco/efectos adversos , Tabaco sin Humo
11.
Eur J Drug Metab Pharmacokinet ; 47(2): 211-221, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-34923602

RESUMEN

BACKGROUND AND OBJECTIVES: Nicotine pouches (NPs) are a relatively new type of oral smokeless tobacco-free nicotine product. Currently, few data are available on the nicotine pharmacokinetics or subjective effects of NP use. The objective of this study was to determine and compare the pharmacokinetics of nicotine absorption into the blood from different NP variants and a combustible cigarette. METHODS: In a randomised, controlled, crossover clinical study, nicotine pharmacokinetics and subjective effects were compared among commercially available NPs (five different brands; 6-10 mg nicotine/pouch) and a combustible cigarette. During an 8-day confinement period, 35 healthy adult participants who were current dual users of snus and combustible cigarettes used one study product each day for a defined period following overnight nicotine abstinence. RESULTS: Nicotine maximum plasma concentration (Cmax) and area under the plasma concentration-time curve between 0 and 6 h (AUC0-6h) were significantly greater for the Lyft 10 mg NP than for the cigarette (both p < 0.0001), while the other NPs had Cmax and AUC0-6h values that were either greater than or similar to those of the cigarette. Plasma nicotine concentration was not associated with the nicotine contents of the NPs. Time to reach maximum plasma concentration (Tmax) was higher for all NPs (60-65 min) than for the cigarette (7 min). Regarding subjective effects, liking and intent to use product again scores were higher for the cigarette than for any NP and were lowest for the NP with the lowest nicotine content. CONCLUSIONS: This study provides important insight into nicotine pharmacokinetics and subjective effects during NP use, and demonstrates that NPs can provide nicotine in amounts sufficient to replicate cigarette smokers' nicotine uptake following a switch from conventional cigarettes to these potentially less harmful NP products. Further studies are required to ascertain how physical characteristics of NPs other than nicotine content may affect nicotine delivery, pharmacokinetics and subjective responses. ISRCTN CLINICAL TRIAL REGISTRY: ISRCTN17828518.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Productos de Tabaco , Adulto , Estudios Cruzados , Humanos , Nicotina/farmacocinética , Fumadores
12.
Clin Pharmacol Ther ; 111(5): 1066-1074, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-34826137

RESUMEN

Nicotine absorption rate influences tobacco products' addictiveness. For smokeless tobacco, nicotine buccal absorption is associated with its free-base form; the pH of smokeless tobacco defines the proportion of free-base (i.e., unprotonated) vs. protonated nicotine. This was the first study to compare nicotine pharmacokinetics (PK) and pharmacodynamics (PD) after the use of commercial smokeless tobacco products that were experimentally manipulated to differ only in pH and percent free-base nicotine. Moist snuff users (N = 40) completed four crossover visits and used a single 2 g portion of Copenhagen Original Long Cut amended to 4 pH levels: 5.0, 7.7, 8.2, and 8.6 (free-base nicotine 0.1, 32, 60, and 79%) for 30 minutes. Nicotine PK and PD were assessed for 4 hours post-use. Nicotine PK substantially depends on its free-base proportion, with more than 4-fold increases in mean plasma nicotine maximum concentration and area under the curve over 240 minutes (3.9 to 16.7 ng/mL; 385 to 1810 ng min/mL, respectively, both P < 0.001) from pH 5.0 to 8.6. The autonomic cardiovascular effects of smokeless tobacco use reflected percent free-base nicotine, with small (albeit significant) systematic increases in heart rate and blood pressure associated with free-base nicotine. Smokeless tobacco product pH and percent free-base nicotine play a major role in the rate and extent of nicotine absorption, determining product PD effects and abuse potential. Research and regulation of smokeless tobacco products should consider both total nicotine content and product pH. Further research may address the impact of modifying pH on the addictiveness of smokeless tobacco and associated use behaviors.


Asunto(s)
Tabaco sin Humo , Estudios Cruzados , Humanos , Concentración de Iones de Hidrógeno , Nicotina/efectos adversos , Nicotina/farmacocinética , Absorción por la Mucosa Oral , Tabaco sin Humo/efectos adversos
13.
J Clin Pharmacol ; 61 Suppl 2: S18-S36, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-34396553

RESUMEN

Electronic nicotine delivery systems (ENDS) such as e-cigarettes and heated tobacco products are novel battery-operated devices that deliver nicotine without combustion of tobacco. Because cigarette smoking is sustained by nicotine addiction and the toxic combustion products are mainly responsible for the harmful effects of smoking, ENDS could be used to promote smoking cessation while exposing users to lower levels of toxicants compared with conventional cigarettes. The currently available evidence from clinical and observational studies indicates a potential role of e-cigarettes as smoking cessation aids, although many continue to use e-cigarettes long after quitting smoking. Nicotine and toxicant delivery vary considerably by device and depend on the characteristics of the e-liquid formulation. Because smokers tend to titrate their nicotine intake to maintain their desired pharmacologic effects, device and liquid characteristics need to be considered when using ENDS as an aid to quit smoking. Factors potentially limiting their use are the currently still unknown long-term safety of these products and concerns regarding widespread use among youth. Implications of clinical pharmacology data on ENDS for the cigarette endgame and regulation by the U.S. Food and Drug administration are discussed.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Nicotiana/efectos adversos , Nicotina/farmacología , Tabaquismo/fisiopatología , Área Bajo la Curva , Encéfalo/efectos de los fármacos , Humanos , Tasa de Depuración Metabólica , Nicotina/química , Nicotina/farmacocinética , Prevalencia , Cese del Hábito de Fumar/métodos , Estados Unidos/epidemiología , United States Food and Drug Administration
14.
PLoS One ; 16(7): e0254247, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34329335

RESUMEN

Use of nicotine-specific monoclonal antibodies (mAbs) to sequester and reduce nicotine distribution to brain has been proposed as a therapeutic approach to treat nicotine addiction (the basis of tobacco use disorder). A series of monoclonal antibodies with high affinity for nicotine (nic•mAbs) was isolated from B-cells of vaccinated smokers. Genes encoding 32 unique nicotine binding antibodies were cloned, and the mAbs expressed and tested by surface plasmon resonance to determine their affinity for S-(-)-nicotine. The highest affinity nic•mAbs had binding affinity constants (KD) between 5 and 67 nM. The 4 highest affinity nic•mAbs were selected to undergo additional secondary screening for antigen-specificity, protein properties (including aggregation and stability), and functional in vivo studies to evaluate their capacity for reducing nicotine distribution to brain in rats. The 2 most potent nic•mAbs in single-dose nicotine pharmacokinetic experiments were further tested in a dose-response in vivo study. The most potent lead, ATI-1013, was selected as the lead candidate based on the results of these studies. Pretreatment with 40 and 80 mg/kg ATI-1013 reduced brain nicotine levels by 56 and 95%, respectively, in a repeated nicotine dosing experiment simulating very heavy smoking. Nicotine self-administration was also significantly reduced in rats treated with ATI-1013. A pilot rat 30-day repeat-dose toxicology study (4x200mg/kg ATI-1013) in the presence of nicotine indicated no drug-related safety concerns. These data provide evidence that ATI-1013 could be a potential therapy for the treatment of nicotine addiction.


Asunto(s)
Anticuerpos Monoclonales , Afinidad de Anticuerpos , Encéfalo/metabolismo , Nicotina , Tabaquismo , Animales , Anticuerpos Monoclonales/química , Anticuerpos Monoclonales/farmacocinética , Anticuerpos Monoclonales/farmacología , Complejo Antígeno-Anticuerpo/química , Humanos , Nicotina/química , Nicotina/farmacocinética , Ratas , Ratas Sprague-Dawley , Tabaquismo/tratamiento farmacológico , Tabaquismo/metabolismo
15.
Clin Pharmacol Ther ; 110(3): 599-606, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34165800

RESUMEN

Smoking continues to be the leading preventable contributor to death worldwide. Twin studies have suggested a significant genetic contribution underlying most smoking behaviors (40-70% heritability estimates). Candidate gene studies of smoking phenotypes have identified several pharmacogenes implicated in nicotine's pharmacokinetics (CYP2A6, CYP2B6, CYP2A13, FMOs, UGTs, and OCT2), and nicotine's pharmacodynamic response in the central nervous system (nicotinic acetylcholine receptors, as well as through the dopaminergic and serotonergic systems). Subsequent genome-wide association studies (GWAS) have confirmed the role of certain pharmacogenes through hypothesis-free approaches. Furthermore, pharmacogenes that alter the efficacy of smoking cessation pharmacotherapies, including nicotine replacement therapies, bupropion, and varenicline, may also impact quitting success. In this brief review we highlight the role of pharmacogenes in smoking behaviors, such as smoking status, consumption, nicotine dependence, spontaneous quitting, and altered abstinence to pharmacotherapies; We provide examples from initial candidate gene associations and subsequent GWAS. The genes CYP2A6 and the CHRNA5-A3-B4 confer the most replicated sources of genetic variation in smoking behaviors, likely due to their importance in nicotine's pharmacology. We will also provide examples of genetic scoring approaches, and the role of rare variants in explaining a portion of the missing heritability in smoking behaviors.


Asunto(s)
Fumar/tratamiento farmacológico , Fumar/genética , Animales , Citocromo P-450 CYP2A6/metabolismo , Estudios de Asociación Genética/métodos , Variación Genética/genética , Estudio de Asociación del Genoma Completo/métodos , Humanos , Nicotina/farmacocinética , Farmacogenética/métodos , Fenotipo , Fumar/metabolismo , Tabaquismo/genética , Tabaquismo/metabolismo
16.
Sci Rep ; 11(1): 12078, 2021 06 08.
Artículo en Inglés | MEDLINE | ID: mdl-34103661

RESUMEN

The emergence of e-cigarettes on the consumer market led to a tremendous rise in e-cigarette consumption among adolescents in the United States. The success of JUUL and other pod systems was linked to its high nicotine delivery capacity. In compliance with the European Tobacco Product directive, liquid nicotine contents in the European JUUL variants are limited to 20 mg/mL or below. A short time after launching the initial version in Europe, JUUL pods have been modified in terms of the wick material used. This modification has been demonstrated previously to lead to an elevated aerosol generation, consequently, to a larger amount of nicotine per puff generated. The present study was designed to assess whether the mentioned differences between the "initial" and "modified" JUUL versions may cause a significant difference during consumption, and how nicotine delivery compares with tobacco cigarettes. In this single-center three-arm study, nicotine pharmacokinetics and influence on urge to smoke/vape were compared for tobacco cigarettes, the "initial" version of the European JUUL, and the "modified" version of the European JUUL. Participants, 15 active smokers and 17 active e-cigarette users, were instructed to consume their study product according to a pre-directed puffing protocol. Venous blood was sampled for nicotine analysis to cover the acute phase and the first 30 min after starting. Nicotine delivery and the reduction of urge to smoke/vape upon usage of both European JUUL variants were lower in comparison to tobacco cigarettes. This suggests a lower addictive potential. Modification of the pod design did not result in significant differences at the first ten puffs, as confirmed by a vaping machine experiment. Apparently, the limitations by the initially used wick material only come into effect after longer usage time.


Asunto(s)
Ansia/efectos de los fármacos , Sistemas Electrónicos de Liberación de Nicotina , Nicotina , Vapeo/sangre , Adolescente , Adulto , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nicotina/administración & dosificación , Nicotina/farmacocinética
17.
AAPS J ; 23(3): 49, 2021 03 29.
Artículo en Inglés | MEDLINE | ID: mdl-33782803

RESUMEN

It has proven challenging to quantify 'drug input' from a formulation to the viable skin because the epidermal and dermal targets of topically applied drugs are difficult, if not impossible, to access in vivo. Defining the drug input function to the viable skin with a straightforward and practical experimental approach would enable a key component of dermal pharmacokinetics to be characterised. It has been hypothesised that measuring drug uptake into and clearance from the stratum corneum (SC) by tape-stripping allows estimation of a topical drug's input function into the viable tissue. This study aimed to test this idea by determining the input of nicotine and lidocaine into the viable skin, following the application of commercialised transdermal patches to healthy human volunteers. The known input rates of these delivery systems were used to validate and assess the results from the tape-stripping protocol. The drug input rates from in vivo tape-stripping agreed well with the claimed delivery rates of the patches. The experimental approach was then used to determine the input of lidocaine from a marketed cream, a typical topical product for which the amount of drug absorbed has not been well-characterised. A significantly higher delivery of lidocaine from the cream than from the patch was found. The different input rates between drugs and formulations in vivo were confirmed qualitatively and quantitatively in vitro in conventional diffusion cells using dermatomed abdominal pig skin.


Asunto(s)
Epidermis/metabolismo , Absorción Cutánea , Crema para la Piel/farmacocinética , Parche Transdérmico , Administración Cutánea , Adulto , Animales , Evaluación Preclínica de Medicamentos/métodos , Femenino , Voluntarios Sanos , Humanos , Lidocaína/administración & dosificación , Lidocaína/farmacocinética , Masculino , Nicotina/administración & dosificación , Nicotina/farmacocinética , Crema para la Piel/administración & dosificación , Porcinos
18.
Clin Pharmacol Drug Dev ; 10(3): 241-250, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33502815

RESUMEN

Novel noncombustible tobacco products offer adult smokers (ASs) alternatives to combustible cigarettes lower on the continuum of risk; however, the abuse potential of such products has not been well studied. The objective of this study was to evaluate the abuse potential of 2 chewable tobacco-derived nicotine containing products, VERVE Chews Blue Mint (test 1) and Green Mint (test 2), in ASs compared with own-brand cigarettes (CIGS) and nicotine polacrilex gum (GUM) using subjective measures and nicotine pharmacokinetics. ASs used the test products during a 5-day at-home trial prior to completing an in-clinic 4-period randomized crossover study. During the study ASs used test products, CIGS, and GUM once on separate days. Responses to Tobacco/Nicotine Withdrawal and Direct Effects of Product questionnaires were documented, and blood samples were collected to assess nicotine pharmacokinetics during each product use. Nicotine pharmacokinetic parameters (Cmax and AUC) were statistically significantly lower with use of test products compared with CIGS and statistically significantly higher compared with GUM. No appreciable differences were noted between the 2 flavors for any of the end points measured. Reductions in maximum urge to smoke and maximum responses to the question "Is the Product 'Pleasant' Right Now?" for the test products were statistically significantly lower than CIGS but comparable to GUM. Similar results were observed for responses to other items in the 2 questionnaires. The test products, under the conditions of this study, carry lower abuse potential than own-brand cigarettes and similar to nicotine polacrilex gum.


Asunto(s)
Nicotina/farmacocinética , Fumadores/psicología , Síndrome de Abstinencia a Sustancias/psicología , Productos de Tabaco/efectos adversos , Dispositivos para Dejar de Fumar Tabaco/efectos adversos , Administración Oral , Adulto , Anciano , Goma de Mascar/efectos adversos , Goma de Mascar/estadística & datos numéricos , Estudios Cruzados , Femenino , Aromatizantes , Humanos , Masculino , Persona de Mediana Edad , Nicotina/sangre , Nicotina/química , Fumadores/estadística & datos numéricos , Detección de Abuso de Sustancias/métodos , Síndrome de Abstinencia a Sustancias/epidemiología , Encuestas y Cuestionarios , Productos de Tabaco/estadística & datos numéricos , Cese del Uso de Tabaco/métodos , Dispositivos para Dejar de Fumar Tabaco/estadística & datos numéricos
19.
Nicotine Tob Res ; 23(6): 947-955, 2021 05 24.
Artículo en Inglés | MEDLINE | ID: mdl-33486526

RESUMEN

INTRODUCTION: This randomized, open-label, crossover clinical study evaluated nicotine pharmacokinetics (PK) and subjective effects of the JUUL System (JS; Juul Labs, Inc.) with three nicotine concentrations compared to the usual brand (UB) cigarettes in 24 adult smokers. METHODS: At five study visits, subjects used either the JS in 59 mg/mL, JS 18 mg/mL (two visits), and JS 9 mg/mL (all tobacco-flavored) or smoked their UB cigarette first during a controlled puffing sequence (CPS) and then ad libitum (5 min) use sessions. Blood samples were taken at specified timepoints for 60 min in each session. The modified Product Evaluation Scale assessed subjective effects 30-min post-use in the CPS session. RESULTS: Maximum plasma nicotine concentration (Cmax-BL), total nicotine exposure (AUC0-60-BL), and rate of plasma nicotine rise were significantly lower for all JS products compared to subjects' UB cigarette in CPS and ad libitum use sessions. In both use sessions these PK parameters were significantly higher for JS 59 mg/mL compared to 18 and 9 mg/mL. Subjective measures of cigarette craving relief and "Enough Nicotine" for JS 59 mg/mL did not differ significantly from UB cigarettes, but JS 18 and 9 mg/mL were rated significantly lower than JS 59 mg/mL and UB cigarettes. CONCLUSIONS: Nicotine exposure and subjective relief were directly related to JS nicotine concentration: higher nicotine concentrations gave rise to significantly greater plasma nicotine levels and relief from craving. Heavier and more dependent smokers may require the greater nicotine delivery of JS 59 mg/mL to successfully transition away from cigarettes. IMPLICATIONS: It has been suggested that electronic nicotine delivery systems (ENDS) and other alternative nicotine delivery products that more closely mimic the nicotine pharmacokinetics (PK) of cigarettes may facilitate smokers transitioning away from cigarettes. We examined nicotine PK and subjective effects of JUUL System (JS) ENDS with three nicotine concentrations (59, 18 and 9 mg/mL) compared to combustible cigarettes. Nicotine delivery from JS ENDS was nicotine concentration dependent, with higher nicotine concentrations giving rise to higher nicotine exposure. These findings suggest that heavier and more dependent smokers may require ENDS with nicotine concentrations greater than 20 mg/mL to successfully transition away from cigarettes.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina , Nicotina , Productos de Tabaco , Adulto , Estudios Cruzados , Humanos , Nicotina/farmacocinética , Fumadores
20.
Sci Rep ; 10(1): 19980, 2020 11 24.
Artículo en Inglés | MEDLINE | ID: mdl-33235307

RESUMEN

Smokers who switch completely to e-cigarettes may reduce their relative risk of tobacco-related disease. Effective nicotine delivery from e-cigarettes is important in consumer acceptance. We assessed whether protonated nicotine and e-cigarette devices delivering greater aerosol mass increase nicotine delivery and product liking. A randomised controlled non-blinded eight-arm crossover study was used to assess plasma nicotine pharmacokinetics and product liking for two e-cigarettes (Vype ePen3 and Vype ePen) with various nicotine e-liquid formulations and a conventional cigarette among 24 healthy dual-users of cigarettes and e-cigarettes. Product use and puff count were also assessed. Results show that nicotine bioavailability was greater for Vype ePen3 with greater aerosol mass delivery than for Vype ePen (Cmax, p = 0.0073; AUC0-120 min, p = 0.0102). Protonated nicotine (18 mg/mL, medium protonation) e-liquid yielded higher nicotine bioavailability than unprotonated nicotine (18 mg/mL) e-liquid (Cmax, p = 0.0001; AUC0-120 min, p = 0.0026). There was no significant difference in Tmax between e-liquids. Nicotine bioavailability did not differ between nicotine benzoate formulation (30 mg/mL nicotine, high protonation) and combustible cigarettes (Cmax, p = 0.79; AUC0-120 min, p = 0.13). Vype ePen3 with protonated nicotine delivers nicotine more efficiently with the potential to increase product liking relative to earlier devices using unprotonated e-liquid.


Asunto(s)
Sistemas Electrónicos de Liberación de Nicotina/estadística & datos numéricos , Nicotina/farmacocinética , Adulto , Disponibilidad Biológica , Estudios Cruzados , Femenino , Voluntarios Sanos , Humanos , Masculino , Persona de Mediana Edad , Nicotina/sangre , Fumadores , Fumar/sangre , Nicotiana , Productos de Tabaco
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...