Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.329
Filtrar
4.
Int J Cardiol ; 408: 132112, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38697399

RESUMEN

BACKGROUND: Transcatheter mitral valve replacement (TMVR) is an alternative to conventional surgery to treat severe mitral disease but its use is limited by the risk of left ventricular outflow tract obstruction (LVOTO). Screening depends on ECG-gated computed tomography (CT) that is not widely available and requires contrast. We developed and validated a transthoracic echocardiographic (TTE) method to assess the risk of LVOTO after TMVR with the Tendyne System. METHODS: We measured the LVOT longitudinal area on preoperative TTE dataset of patients screened for TMVR. The LVOT was measured as the box-area included by the aortic valve annulus, the anterior mitral leaflet (AML), the c-septum distance line, and the respective length of the AML on the interventricular septum. We analyzed the correlation between the TTE LVOT-box and the CT-measured neoLVOT area. Prediction performance for eligible patients was tested with ROC curves. RESULTS: Thirty-nine patients were screened, out of 14 patients (36%) not eligible for TMVR, 8 had risk of LVOTO. We found a linear correlation between the TTE LVOT-box and the CT-measured Neo-LVOT (r = 0.6, p = 0.002). ROC curve showed that the method is specific and sensitive and the cut-off value of the measure LVOT-box is 350 mm2. CONCLUSIONS: The proposed method is reliable to evaluate the risk of LVOTO after TMR with the Tendyne System. It is quick and easy and can be used as a first-line assessment in the outpatient clinic. Patients with LVOT-box <350 mm2 should not be further screened with ECG-gated cardiac CT.


Asunto(s)
Ecocardiografía , Obstrucción del Flujo Ventricular Externo , Humanos , Femenino , Masculino , Ecocardiografía/métodos , Anciano , Medición de Riesgo/métodos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Persona de Mediana Edad , Estudios Retrospectivos , Cateterismo Cardíaco/métodos , Anciano de 80 o más Años , Insuficiencia de la Válvula Mitral/diagnóstico por imagen , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/diagnóstico por imagen , Válvula Mitral/cirugía
5.
Int J Cardiol ; 407: 132027, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-38583591

RESUMEN

BACKGROUND: In patients with transposition of the great arteries and an arterial switch operation (TGA-ASO) right ventricular outflow tract (RVOT) obstruction is a common complication requiring one or more RVOT interventions. OBJECTIVES: We aimed to assess cardiopulmonary exercise capacity and right ventricular function in patients stratified for type of RVOT intervention. METHODS: TGA-ASO patients (≥16 years) were stratified by type of RVOT intervention. The following outcome parameters were included: predicted (%) peak oxygen uptake (peak VO2), tricuspid annular plane systolic excursion (TAPSE), tricuspid Lateral Annular Systolic Velocity (TV S'), right ventricle (RV)-arterial coupling (defined as TAPSE/RV systolic pressure ratio), and N-terminal proBNP (NT-proBNP). RESULTS: 447 TGA patients with a mean age of 25.0 (interquartile range (IQR) 21-29) years were included. Patients without previous RVOT intervention (n = 338, 76%) had a significantly higher predicted peak VO2 (78.0 ± 17.4%) compared to patients with single approach catheter-based RVOT intervention (73.7 ± 12.7%), single approach surgical RVOT intervention (73.8 ± 28.1%), and patients with multiple approach RVOT intervention (66.2 ± 14.0%, p = 0.021). RV-arterial coupling was found to be significantly lower in patients with prior catheter-based and/or surgical RVOT intervention compared to patients without any RVOT intervention (p = 0.029). CONCLUSIONS: TGA patients after a successful arterial switch repair have a decreased exercise capacity. A considerable amount of TGA patients with either catheter or surgical RVOT intervention perform significantly worse compared to patients without RVOT interventions.


Asunto(s)
Transposición de los Grandes Vasos , Humanos , Masculino , Femenino , Transposición de los Grandes Vasos/cirugía , Transposición de los Grandes Vasos/fisiopatología , Adulto , Adulto Joven , Europa (Continente)/epidemiología , Obstrucción del Flujo Ventricular Externo/cirugía , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Operación de Switch Arterial/métodos , Operación de Switch Arterial/efectos adversos , Tolerancia al Ejercicio/fisiología , Prueba de Esfuerzo/métodos , Resultado del Tratamiento , Función Ventricular Derecha/fisiología , Estudios de Seguimiento
7.
Catheter Cardiovasc Interv ; 103(6): 924-933, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38597297

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) is a non-surgical treatment for right ventricular outflow tract (RVOT) dysfunction. During PPVI, a stented valve, delivered via catheter, replaces the dysfunctional pulmonary valve. Stent oversizing allows valve anchoring within the RVOT, but overexpansion can intrude on the surrounding structures. Potentially dangerous outcomes include aortic valve insufficiency (AVI) from aortic root (AR) distortion and myocardial ischemia from coronary artery (CA) compression. Currently, risks are evaluated via balloon angioplasty/sizing before stent deployment. Patient-specific finite element (FE) analysis frameworks can improve pre-procedural risk assessment, but current methods require hundreds of hours of high-performance computation. METHODS: We created a simplified method to simulate the procedure using patient-specific FE models for accurate, efficient pre-procedural PPVI (using balloon expandable valves) risk assessment. The methodology was tested by retrospectively evaluating the clinical outcome of 12 PPVI candidates. RESULTS: Of 12 patients (median age 14.5 years) with dysfunctional RVOT, 7 had native RVOT and 5 had RV-PA conduits. Seven patients had undergone successful RVOT stent/valve placement, three had significant AVI on balloon testing, one had left CA compression, and one had both AVI and left CA compression. A model-calculated change of more than 20% in lumen diameter of the AR or coronary arteries correctly predicted aortic valve sufficiency and/or CA compression in all the patients. CONCLUSION: Agreement between FE results and clinical outcomes is excellent. Additionally, these models run in 2-6 min on a desktop computer, demonstrating potential use of FE analysis for pre-procedural risk assessment of PPVI in a clinically relevant timeframe.


Asunto(s)
Cateterismo Cardíaco , Análisis de Elementos Finitos , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Modelos Cardiovasculares , Modelación Específica para el Paciente , Diseño de Prótesis , Válvula Pulmonar , Humanos , Válvula Pulmonar/fisiopatología , Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Implantación de Prótesis de Válvulas Cardíacas/instrumentación , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Medición de Riesgo , Adolescente , Resultado del Tratamiento , Factores de Riesgo , Masculino , Niño , Estudios Retrospectivos , Femenino , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Adulto Joven , Valor Predictivo de las Pruebas , Hemodinámica , Stents , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Toma de Decisiones Clínicas , Adulto
9.
Kyobu Geka ; 77(3): 191-195, 2024 Mar.
Artículo en Japonés | MEDLINE | ID: mdl-38465491

RESUMEN

We experienced a case of surgical aortic valve re-replacement due to structural valve deterioration caused by pannus formation 4 years after transcatheter aortic valve replacement( TAVR). The patient underwent surgery because the mean transvalvular pressure gradient increased to 48 mmHg on echocardiography. Contrast-enhanced computed tomography (CT) was useful for predicting the site of adhesion to surrounding tissue preoperatively and exploring the presence of the pannus. Intraoperative findings showed the TAVR valve was covered with neointima except around the origins of the left and right coronary arteries and was firmly adhered to the surrounding tissues. As residual pannus was present in the subvalvular tissues, it was carefully removed. The explanted TAVR valve functioned well with good opening and closure. The postoperative course was uneventful. Pannus formation can result from mechanical stress. TAVR valves put significantly greater stress on the left ventricular outflow tract than surgical valves and may be more likely to cause pannus formation.


Asunto(s)
Estenosis de la Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Pannus , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Válvula Aórtica/diagnóstico por imagen , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/diagnóstico por imagen , Estenosis de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía
10.
Artículo en Inglés | MEDLINE | ID: mdl-38522866

RESUMEN

Patients with many forms of congenital heart disease (CHD) and hypertrophic cardiomyopathy undergo surgical intervention to relieve left ventricular outflow tract obstruction (LVOTO). Cardiovascular Computed Tomography (CCT) defines the complex pathway from the ventricle to the outflow tract and can be visualized in 2D, 3D, and 4D (3D in motion) to help define the mechanism and physiologic significance of obstruction. Advanced cardiac visualization may aid in surgical planning to relieve obstruction in the left ventricular outflow tract, aortic or neo-aortic valve and the supravalvular space. CCT scanner technology has advanced to achieve submillimeter, isotropic spatial resolution, temporal resolution as low as 66 msec allowing high-resolution imaging even at the fast heart rates and small cardiac structures of pediatric patients ECG gating techniques allow radiation exposure to be targeted to a minimal portion of the cardiac cycle for anatomic imaging, and pulse modulation allows cine imaging with a fraction of radiation given during most of the cardiac cycle, thus reducing radiation dose. Scanning is performed in a single heartbeat or breath hold, minimizing the need for anesthesia or sedation, for which CHD patents are highest risk for an adverse event. Examples of visualization of complex left ventricular outflow tract obstruction in the subaortic, valvar and supravalvular space will be highlighted, illustrating the novel applications of CCT in this patient subset.


Asunto(s)
Cardiopatías Congénitas , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Niño , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Cardiopatías Congénitas/complicaciones , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Toma de Decisiones , Tomografía
11.
Pediatr Cardiol ; 45(5): 967-975, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38480569

RESUMEN

Left ventricular outflow tract obstruction (LVOTO) remains a significant complication after primary repair of interrupted aortic arch with ventricular septal defect (IAA-VSD). Clinical and echocardiographic predictors for LVOTO reoperation are controversial and procedures to prophylactically prevent future LVOTO are not reliable. However, it is important to identify the patients at risk for future LVOTO intervention after repair of IAA-VSD. Patients who underwent single-stage IAA-VSD repair at our center 2006-2021 were retrospectively reviewed, excluding patients with associated cardiac lesions. Two-dimensional measurements, LVOT gradients, and 4-chamber (4C) and short-axis (SAXM) strain were obtained from preoperative and predischarge echocardiograms. Univariate risk analysis for LVOTO reoperation was performed using unpaired t-test. Thirty patients were included with 21 (70%) IAA subtype B and mean weight at surgery 3.0 kg. Repair included aortic arch patch augmentation in 20 patients and subaortic obstruction intervention in three patients. Seven (23%) required reoperations for LVOTO. Patient characteristics were similar between patients who required LVOT reoperation and those who did not. Patch augmentation was not associated with LVOTO reintervention. Patients requiring reintervention had significantly smaller LVOT AP diameter preoperatively and at discharge, and higher LVOT velocity, smaller AV annular diameter, and ascending aortic diameter at discharge. There was an association between LVOT-indexed cross-sectional area (CSAcm2/BSAm2) ≤ 0.7 and reintervention. There was no significant difference in 4C or SAXM strain in patients requiring reintervention. LVOTO reoperation was not associated with preoperative clinical or surgical variables but was associated with smaller LVOT on preoperative echo and smaller LVOT, smaller AV annular diameter, and increased LVOT velocity at discharge.


Asunto(s)
Aorta Torácica , Ecocardiografía , Defectos del Tabique Interventricular , Reoperación , Obstrucción del Flujo Ventricular Externo , Humanos , Femenino , Estudios Retrospectivos , Masculino , Aorta Torácica/cirugía , Aorta Torácica/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/cirugía , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Defectos del Tabique Interventricular/cirugía , Defectos del Tabique Interventricular/diagnóstico por imagen , Lactante , Complicaciones Posoperatorias , Recién Nacido , Resultado del Tratamiento , Procedimientos Quirúrgicos Cardíacos/métodos
13.
Heart Vessels ; 39(6): 556-562, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38368576

RESUMEN

Cardiac magnetic resonance imaging (CMR) often shows discrepancies between right ventricular outflow tract (RVOT) flow and left ventricular outflow tract flow in patients with late-stage repaired tetralogy of Fallot (rTOF), leading to potential errors in pulmonary regurgitation fraction (PRF) assessment. This study aimed to identify the conditions under which RVOT flow can be acutely evaluated using four-dimensional (4D) flow CMR. Twenty-seven consecutive patients with rTOF underwent both two-dimensional phase-contrast (2D PC) and 4D flow CMR between 2016 and 2018, excluding those with peripheral pulmonary artery stenosis, RVOT conduit replacement, unknown surgical method, and an aortic valve regurgitation greater than 20%. Seven healthy controls also underwent only 4D Flow CMR. All healthy controls and fifteen patients with rTOF showed laminar RVOT flow, while seven patients exhibited helical, and four patients exhibited vortical RVOT flow in 4D flow CMR visualization. Flow-volume concordance between the pulmonary artery and aortic flow was significantly lower in patients with rTOF and PRF > 40% in 2D PC CMR. This concordance rate in the suprapulmonary valve was high in both the TOF and control groups, comparing at five RVOT locations in 4D flow CMR. Regarding RVOT flow regurgitation in 4D flow, the whole bulk evaluation exhibited greater variation depending on the flow type compared to the whole pixel-wise evaluation. The study confirmed the flow volume at the upper section of the pulmonary valve as the most accurate correlate of aortic flow volume. Furthermore, the 4D flow CMR using the pixel-wise method demonstrated superior accuracy compared to the traditional bulk flow method.


Asunto(s)
Imagen por Resonancia Cinemagnética , Tetralogía de Fallot , Humanos , Tetralogía de Fallot/cirugía , Tetralogía de Fallot/fisiopatología , Masculino , Femenino , Adulto , Imagen por Resonancia Cinemagnética/métodos , Velocidad del Flujo Sanguíneo/fisiología , Adolescente , Procedimientos Quirúrgicos Cardíacos/métodos , Adulto Joven , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Función Ventricular Derecha/fisiología , Estudios Retrospectivos , Insuficiencia de la Válvula Pulmonar/fisiopatología , Insuficiencia de la Válvula Pulmonar/cirugía , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/diagnóstico , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Niño , Obstrucción del Flujo Ventricular Externo/fisiopatología , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen
16.
J Thorac Cardiovasc Surg ; 167(2): 439-449.e6, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37356475

RESUMEN

OBJECTIVE: This study reviewed the application of curved and bileaflet designs to pulmonary expanded polytetrafluoroethylene conduits with diameters of 10 to 16 mm and characterized this conduit on in vitro experiment, including particle image velocimetry. METHODS: All patients who received this conduit between 2010 and 2022 were evaluated. Three 16-mm conduits were tested in a circulatory simulator at different cardiac outputs (1.5-3.6 L/minute) and bending angles (130°-150°). RESULTS: Fifty consecutive patients were included. The median operative body weight was 8.4 kg (range, 2.6-12 kg); 10-, 12-, 14-, and 16-mm conduits were used in 1, 4, 6, and 39 patients, respectively. In 34 patients, the conduit was implanted in a heterotopic position. The overall survival rate was 89% at 8 years with 3 nonvalve-related deaths. There were 10 conduit replacements; 5 16-mm conduits (after 8 years) and 1 12-mm conduit (after 6 years) due to conduit stenosis, and the remaining 4 for reasons other than conduit failure. Freedom from conduit replacement was 89% and 82% at 5 and 8 years, respectively. Linear mixed-effects models with echocardiographic data implied that 16-mm conduits were durable with a peak velocity <3.5 m/second and without moderate/severe regurgitation until the patient's weight reached 25 kg. In experiments, peak transvalvular pressure gradients were 11.5 to 25.5 mm Hg, regurgitant fractions were 8.0% to 14.4%, and peak Reynolds shear stress in midsystolic phase was 29 to 318 Pa. CONCLUSIONS: Our conduits with curved and bileaflet designs have acceptable clinical durability and proven hydrodynamic profiles, which eliminate valve regurgitation and serve as a reliable bridge to subsequent conduit replacement.


Asunto(s)
Cardiopatías Congénitas , Prótesis Valvulares Cardíacas , Obstrucción del Flujo Ventricular Externo , Humanos , Politetrafluoroetileno , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/cirugía , Estudios Retrospectivos , Prótesis Vascular , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento
17.
Catheter Cardiovasc Interv ; 103(2): 359-366, 2024 02.
Artículo en Inglés | MEDLINE | ID: mdl-38054354

RESUMEN

BACKGROUND: Percutaneous pulmonary valve implantation (PPVI) with the self-expandable Venus P-valve system is a promising treatment for patients with pulmonary regurgitation (PR) and a native right ventricular outflow tract (RVOT). However, limited data is available regarding its midterm outcomes. This study assessed the midterm clinical and echocardiographic outcomes following Venus P-valve implantation. METHODS: From 2013 to 2018, 55 patients with moderate or severe PR after surgical RVOT repair with a transannular or RVOT patch were consecutively enrolled from six hospitals in China. Five-year clinical and echocardiographic outcomes were collected and evaluated. The primary endpoint was a freedom from all-cause mortality and reintervention. RESULTS: At 5 years, the primary endpoint was met for 96% of patients, corresponding to a freedom from all-cause mortality of 96% (95% confidence interval [CI]: 86%-99%) and freedom from reintervention of 98% (95% CI: 87%-100%). Endocarditis was reported in five patients (four patients within 1 year and one patient at 5 years) following PPVI. Transpulmonary gradient and stent orifice diameter remained stable compared to at discharge (p>0.05). No paravalvular leak was reported while only 1 patient gradually increased to moderate PR during follow-up. Significant improvement of RV diameter and LVEF (p<0.001) sustained over the 5-year follow-up, in consistent with remarked improved New York Heart Association(NYHA) functional class (p<0.001). CONCLUSION: The 5-year results of the China VenusP Study demonstrated the midterm benefits of Venus P-valve implantation in the management of patients with severe PR with an enlarged native RVOT by providing sustained symptomatic and hemodynamic improvement.


Asunto(s)
Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Insuficiencia de la Válvula Pulmonar , Válvula Pulmonar , Obstrucción del Flujo Ventricular Externo , Humanos , Insuficiencia de la Válvula Pulmonar/diagnóstico por imagen , Insuficiencia de la Válvula Pulmonar/etiología , Insuficiencia de la Válvula Pulmonar/cirugía , Válvula Pulmonar/diagnóstico por imagen , Válvula Pulmonar/cirugía , Implantación de Prótesis de Válvulas Cardíacas/efectos adversos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Estudios de Seguimiento , Prótesis Valvulares Cardíacas/efectos adversos , Resultado del Tratamiento , Diseño de Prótesis , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/métodos , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Obstrucción del Flujo Ventricular Externo/cirugía
18.
J Cardiol ; 83(6): 401-406, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38000537

RESUMEN

BACKGROUND: Left ventricular outflow tract obstruction [LVOTO; pressure gradient (PG) ≥30 mmHg] is observed in some patients without hypertrophic cardiomyopathy (HCM), and it may develop especially in older patients without HCM (non-HCM). The aim of this study is to investigate if the Valsalva or an upright sitting maneuver can unveil latent LVOTO in patients with non-HCM. METHODS: A total of 33 non-HCM patients with a late peaking or dagger-shaped pulsed Doppler waveform of the LVOT and PG <30 mmHg were included. The Doppler flow velocity of the LVOT was measured at rest, after the Valsalva and a sitting maneuver. Peak PG of ≥30 mmHg after either maneuver was defined as latent LVOTO. The angle between the left ventricular septum and the aorta in the parasternal long-axis view and the apical three-chamber view was measured. RESULTS: Twenty (61 %) of the 33 patients (mean age 74 ±â€¯9 years) were diagnosed with latent LVOTO. Of these, five (25 %) patients were diagnosed after both the Valsalva and sitting maneuver, and 15 (75 %) were diagnosed only after the sitting maneuver. The latent LVOTO group had a significantly smaller angle than the no-LVOTO group between the ventricular septum and the aorta in the parasternal long axis views (107 ±â€¯8° vs. 117 ±â€¯8°, p < 0.01). CONCLUSION: The sitting maneuver is better than the Valsalva maneuver in unveiling latent LVOTO in older, non-HCM patients.


Asunto(s)
Cardiomiopatía Hipertrófica , Obstrucción del Flujo de Salida Ventricular Izquierda , Obstrucción del Flujo Ventricular Externo , Humanos , Anciano , Anciano de 80 o más Años , Sedestación , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/etiología , Maniobra de Valsalva
19.
Gen Thorac Cardiovasc Surg ; 72(1): 58-60, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37620708

RESUMEN

Right ventricular outflow tract reconstruction is repeatedly required after the Rastelli procedure. However, standard right ventricular outflow tract reconstruction using direct anastomosis on the posterior right ventricular outflow tract wall is unfeasible in cases with severe calcification. Herein, we present a novel technique called the "lantern procedure," which can fix the prosthetic pulmonary valve without anastomosis to the calcified right ventricular outflow tract wall.


Asunto(s)
Calcinosis , Válvula Pulmonar , Obstrucción del Flujo Ventricular Externo , Humanos , Válvula Pulmonar/cirugía , Ventrículos Cardíacos , Calcinosis/diagnóstico por imagen , Calcinosis/cirugía , Obstrucción del Flujo Ventricular Externo/diagnóstico por imagen , Obstrucción del Flujo Ventricular Externo/cirugía , Resultado del Tratamiento
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...