Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.165
Filtrar
1.
J Biomed Opt ; 29(Suppl 2): S22707, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38962492

RESUMEN

Significance: Adaptive optics fluorescence lifetime ophthalmoscopy (AOFLIO) provides a label-free approach to observe functional and molecular changes at cellular scale in vivo. Adding multispectral capabilities improves interpretation of lifetime fluctuations due to individual fluorophores in the retinal pigment epithelium (RPE). Aim: To quantify the cellular-scale changes in autofluorescence with age and eccentricity due to variations in lipofuscin, melanin, and melanolipofuscin in RPE using multispectral AOFLIO. Approach: AOFLIO was performed on six subjects at seven eccentricities. Four imaging channels ( λ ex / λ em ) were used: 473/SSC, 473/LSC, 532/LSC, and 765/NIR. Cells were segmented and the timing signals of each pixel in a cell were combined into a single histogram, which were then used to compute the lifetime and phasor parameters. An ANOVA was performed to investigate eccentricity and spectral effects on each parameter. Results: A repeatability analysis revealed < 11.8 % change in lifetime parameters in repeat visits for 532/LSC. The 765/NIR and 532/LSC had eccentricity and age effects similar to previous reports. The 473/LSC had a change in eccentricity with mean lifetime and a phasor component. Both the 473/LSC and 473/SSC had changes in eccentricity in the short lifetime component and its relative contribution. The 473/SSC had no trend in eccentricity in phasor. The comparison across the four channels showed differences in lifetime and phasor parameters. Conclusions: Multispectral AOFLIO can provide a more comprehensive picture of changes with age and eccentricity. These results indicate that cell segmentation has the potential to allow investigations in low-photon scenarios such as in older or diseased subjects with the co-capture of an NIR channel (such as 765/NIR) with the desired spectral channel. This work represents the first multispectral, cellular-scale fluorescence lifetime comparison in vivo in the human RPE and may be a useful method for tracking diseases.


Asunto(s)
Oftalmoscopía , Epitelio Pigmentado de la Retina , Humanos , Oftalmoscopía/métodos , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Epitelio Pigmentado de la Retina/citología , Epitelio Pigmentado de la Retina/química , Adulto , Masculino , Femenino , Envejecimiento/fisiología , Persona de Mediana Edad , Anciano , Adulto Joven , Imagen Óptica/métodos , Lipofuscina/metabolismo , Lipofuscina/análisis , Lipofuscina/química , Estudios de Factibilidad
2.
Digit J Ophthalmol ; 30(2): 22-26, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38962668

RESUMEN

Purpose: To describe the Versatile Teaching Eye (VT Eye), a 3D-printed model eye designed to provide an affordable examination simulator, and to report the results of a pilot program introducing the VT Eye and an ophthalmic training curriculum at a teaching hospital in Ghana. Methods: TinkerCAD was used to design the VT Eye, which was printed with ABS plastic. The design features an adapter that permits use of a smartphone as a digital fundus. We developed a set of digital flashcards allowing for an interactive review of a range of retinal pathologies. An analog fundus was developed for practicing traditional slit lamp and indirect examinations as well as retinal laser practice. The model was used for a period of 2 weeks by ophthalmic trainees at Komfo Anokye Teaching Hospital, Kumasi, Ghana, to practice indirect ophthalmoscopy, slit lamp biomicroscopy, smartphone funduscopy, and retinal image drawing. Results were assessed at by means of a pre-/post-training survey of 6 residents. Results: The VT Eye accommodates diverse fundus examination techniques. Its 3D-printed design ensures cost-effective, high-quality replication. When paired with a 20 D practice examination lens, the digital fundus provides a comprehensive, interactive training environment for <$30.00 (USD). This device allows for indirect examination practice without requiring an indirect headset, which may increase the amount of available practice for trainees early in their careers. In the Ghana pilot program, the model's use in indirect examination training sessions significantly boosted residents' confidence in various examination techniques. Comparing pre- and post-session ratings, average reported confidence levels rose by 30% for acquiring clear views of the posterior pole, 42% for visualizing the periphery, and 141% for capturing important pathology using personal smartphones combined with a 20 D lens (all P < 0.05). Conclusions: The VT Eye is readily reproducible and can be easily integrated into ophthalmic training curricula, even in regions with limited resources. It offers an effective and affordable training solution, underscoring its potential for global adoption and the benefits of incorporating innovative technologies in medical education.


Asunto(s)
Modelos Anatómicos , Oftalmología , Impresión Tridimensional , Humanos , Oftalmología/educación , Ghana , Proyectos Piloto , Oftalmoscopía/métodos , Internado y Residencia , Curriculum , Educación de Postgrado en Medicina/métodos
3.
Invest Ophthalmol Vis Sci ; 65(8): 13, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38975944

RESUMEN

Purpose: This study aims at linking subtle changes of fixational eye movements (FEM) in controls and in patients with foveal drusen using adaptive optics retinal imaging in order to find anatomo-functional markers for pre-symptomatic age-related macular degeneration (AMD). Methods: We recruited 7 young controls, 4 older controls, and 16 patients with presymptomatic AMD with foveal drusen from the Silversight Cohort. A high-speed research-grade adaptive optics flood illumination ophthalmoscope (AO-FIO) was used for monocular retinal tracking of fixational eye movements. The system allows for sub-arcminute resolution, and high-speed and distortion-free imaging of the foveal area. Foveal drusen position and size were documented using gaze-dependent imaging on a clinical-grade AO-FIO. Results: FEM were measured with high precision (RMS-S2S = 0.0015 degrees on human eyes) and small foveal drusen (median diameter = 60 µm) were detected with high contrast imaging. Microsaccade amplitude, drift diffusion coefficient, and ISOline area (ISOA) were significantly larger for patients with foveal drusen compared with controls. Among the drusen participants, microsaccade amplitude was correlated to drusen eccentricity from the center of the fovea. Conclusions: A novel high-speed high-precision retinal tracking technique allowed for the characterization of FEM at the microscopic level. Foveal drusen altered fixation stability, resulting in compensatory FEM changes. Particularly, drusen at the foveolar level seemed to have a stronger impact on microsaccade amplitudes and ISOA. The unexpected anatomo-functional link between small foveal drusen and fixation stability opens up a new perspective of detecting oculomotor signatures of eye diseases at the presymptomatic stage.


Asunto(s)
Fijación Ocular , Fóvea Central , Degeneración Macular , Drusas Retinianas , Humanos , Femenino , Drusas Retinianas/fisiopatología , Drusas Retinianas/diagnóstico , Masculino , Fijación Ocular/fisiología , Fóvea Central/diagnóstico por imagen , Fóvea Central/fisiopatología , Fóvea Central/patología , Anciano , Persona de Mediana Edad , Degeneración Macular/fisiopatología , Degeneración Macular/diagnóstico , Adulto , Tomografía de Coherencia Óptica/métodos , Oftalmoscopía/métodos , Agudeza Visual/fisiología , Movimientos Sacádicos/fisiología , Síntomas Prodrómicos
4.
Invest Ophthalmol Vis Sci ; 65(8): 14, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38975943

RESUMEN

Purpose: The purpose of this study was to investigate the spatial distribution of human cone photoreceptors and examine cone density differences between the retinal meridians and quadrants. Method: Using adaptive optics scanning laser ophthalmoscopy, the maculae were imaged in 17 eyes of 11 subjects with normal chorioretinal health aged 54 to 72 years. We measured cone density at 325 points within the central 10 degrees radius of the retina. Cone density spatial distributions along the primary retinal meridians and in four macular quadrants (superior-nasal, superior-temporal, inferior-temporal, and inferior-nasal) were analytically modeled using the polynomial function to assess the meridional and quadrantal difference. Results: The mean and 95% confidence interval for the prediction of cone density along the primary retinal meridians was modeled with a 7-degree one-variable polynomial (R2 = 0.9761, root mean squared error [RMSE] = 0.0585). In the 4 retinal quadrants, cone density distribution was described by a 2-variable polynomial with X degree 3 and Y degree 4 (R² = 0.9834, RMSE = 0.0377). The models suggest no statistically significant difference between medians and between quadrants. However, cone density difference at corresponding spatial locations in different areas can be up to 25.6%. The superior-nasal region has more areas with high cone density, followed by quadrants of inferior-nasal, inferior-temporal, and superior-temporal. Conclusions: Analytical modeling provides comprehensive knowledge of cone distribution across the entire macula. Although modeling analysis suggests no statistically significant difference between medians and between quadrants, the remarkable cone density discrepancies in certain regions should be accounted for in applications requiring sensitive detection of cone variation.


Asunto(s)
Oftalmoscopía , Células Fotorreceptoras Retinianas Conos , Humanos , Células Fotorreceptoras Retinianas Conos/citología , Persona de Mediana Edad , Anciano , Masculino , Femenino , Oftalmoscopía/métodos , Recuento de Células , Mácula Lútea/diagnóstico por imagen
5.
BMC Med Educ ; 24(1): 783, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-39033099

RESUMEN

INTRODUCTION: Non-ophthalmologists often lack sufficient operational training to use a direct ophthalmoscope proficiently, resulting in a global deficit of basic ophthalmological skills among general practitioners. This deficiency hampers the timely diagnosis, referral, and intervention of patients. Consequently, the optimization of teaching tools and methods to enhance teaching efficiency is imperative. This study explores the effectiveness of the Eyesi Direct Ophthalmoscope Simulator (Eyesi) as an innovative tool for fundus examination training. METHODS: Medical undergraduates were randomly assigned to Group A or B (n = 168). All participants completed a pre-training questionnaire. Group A received Eyesi training, while Group B underwent traditional direct ophthalmoscope (TDO) training. Subsequently, participants answered questionnaires relevant to their respective training methods. Both groups exchanged training tools and completed a summary questionnaire. RESULTS: After training, 54.17% of participants believed that images presented by the Eyesi were consistent with the real fundus. Group A scored significantly higher than Group B in fundus structure recognition and self-confidence in examination. The degree of mastery over fundus theory score increased from 6.10 ± 0.13 to 7.74 ± 0.16 (P < 0.001) in Group A, but Group B did not demonstrate a significant difference. We also compared undergraduates' tendencies for different learning purposes, 75.59% of participants preferred the Eyesi to TDO as a training tool, and 88.41% of participants were receptive to introducing the Eyesi in training. CONCLUSION: According to subjective participant feedback, Eyesi outperformed TDO in fundus observation, operational practice, and theoretical learning. It effectively equips undergraduates with fundus examination skills, potentially promoting the use of direct ophthalmoscopes in primary medical institutions.


Asunto(s)
Competencia Clínica , Educación de Pregrado en Medicina , Oftalmoscopios , Entrenamiento Simulado , Humanos , Educación de Pregrado en Medicina/métodos , Masculino , Femenino , Encuestas y Cuestionarios , Oftalmología/educación , Adulto Joven , Estudiantes de Medicina , Evaluación Educacional , Oftalmoscopía/métodos
6.
BMJ Open Ophthalmol ; 9(1)2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38981710

RESUMEN

Lesions of incomplete retinal pigment epithelium and outer retinal atrophy (iRORA) are associated with disease progression in age-related macular degeneration. However, the corresponding functional impact of these precursor lesions is unknown.We present a cross-sectional study of four patients employing clinical-grade MAIA (stimulus size: 0.43°, ~125 µm) and adaptive optics scanning light ophthalmoscope (AOSLO, stimulus size 0.07°, ~20 µm) based microperimetry (MP) to assess the specific impact of iRORA lesions on retinal sensitivity.AOSLO imaging showed overall reduced photoreceptor reflectivity and patches of hyporeflective regions at drusen with interspersed hyper-reflective foci in iRORA regions. MAIA-MP yielded an average retinal sensitivity loss of -7.3±3.1 dB at iRORA lesions compared with the in-eye control. With AOSLO-MP, the corresponding sensitivity loss was 20.1±4.8 dB.We demonstrated that iRORA lesions are associated with a severe impairment in retinal sensitivity. Larger cohort studies will be necessary to validate our findings.


Asunto(s)
Degeneración Macular , Epitelio Pigmentado de la Retina , Tomografía de Coherencia Óptica , Pruebas del Campo Visual , Humanos , Epitelio Pigmentado de la Retina/patología , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Estudios Transversales , Degeneración Macular/patología , Degeneración Macular/diagnóstico , Degeneración Macular/fisiopatología , Femenino , Masculino , Anciano , Tomografía de Coherencia Óptica/métodos , Pruebas del Campo Visual/métodos , Agudeza Visual/fisiología , Anciano de 80 o más Años , Campos Visuales/fisiología , Oftalmoscopía/métodos , Atrofia/patología
7.
Rom J Ophthalmol ; 68(2): 148-151, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39006341

RESUMEN

Objective: Assessment of the utility of smartphone fundoscopy in diagnosing posterior pole pathologies. Methods: An iPhone 12 and a 20D Volk lens were used for smartphone fundoscopy. Patients needing bedside consultation were examined with direct ophthalmoscopy and smartphone fundoscopy. Some patients were examined with this technique after slit lamp examination. Results: Over one year 23 bedside fundus examinations were performed and 2 papilledema were diagnosed. After initial slit lamp examination, photos of various pathologies were taken: age-related macular degeneration, branch retinal artery occlusion, arterial embolus, branch retinal vein occlusion, non-arteritic anterior ischemic optic neuropathy, myelinated retinal nerve fiber layer, choroidal naevus. Discussion: With the 20D lens, the image is overturned, magnified 3,13X, and the field of view is 46°. The utility was demonstrated in literature by teaching students this technique and using it in screening for retinopathy of prematurity. The weighted retinal irradiance was measured in two studies. It was 4,6 mW/cm2 in one and from 0,58 to 2,30 mW/cm2 in the other, within safe limits. Conclusions: Smartphone fundoscopy is a fast, accessible, and safe technique for fundus examinations. Other departments could use it for the diagnosis of papilledema.


Asunto(s)
Fondo de Ojo , Oftalmoscopía , Teléfono Inteligente , Humanos , Oftalmoscopía/métodos , Enfermedades de la Retina/diagnóstico , Masculino , Femenino , Diseño de Equipo
8.
Transl Vis Sci Technol ; 13(7): 13, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-39017629

RESUMEN

Purpose: Several machine learning studies have used optical coherence tomography (OCT) for multiple sclerosis (MS) classification with promising outcomes. Infrared reflectance scanning laser ophthalmoscopy (IR-SLO) captures high-resolution fundus images, commonly combined with OCT for fixed B-scan positions. However, no machine learning research has utilized IR-SLO images for automated MS diagnosis. Methods: This study utilized a dataset comprised of IR-SLO images and OCT data from Isfahan, Iran, encompassing 32 MS and 70 healthy individuals. A number of convolutional neural networks (CNNs)-namely, VGG-16, VGG-19, ResNet-50, ResNet-101, and a custom architecture-were trained with both IR-SLO images and OCT thickness maps as two separate input datasets. The highest performing models for each modality were then integrated to create a bimodal model that receives the combination of OCT thickness maps and IR-SLO images. Subject-wise data splitting was employed to prevent data leakage among training, validation, and testing sets. Results: Overall, images of the 102 patients from the internal dataset were divided into test, validation, and training subsets. Subsequently, we employed a bootstrapping approach on the training data through iterative sampling with replacement. The performance of the proposed bimodal model was evaluated on the internal test dataset, demonstrating an accuracy of 92.40% ± 4.1% (95% confidence interval [CI], 83.61-98.08), sensitivity of 95.43% ± 5.75% (95% CI, 83.71-100.0), specificity of 92.82% ± 3.72% (95% CI, 81.15-96.77), area under the receiver operating characteristic (AUROC) curve of 96.99% ± 2.99% (95% CI, 86.11-99.78), and area under the precision-recall curve (AUPRC) of 97.27% ± 2.94% (95% CI, 86.83-99.83). Furthermore, to assess the model generalization ability, we examined its performance on an external test dataset following the same bootstrap methodology, achieving promising results, with accuracy of 85.43% ± 0.08% (95% CI, 71.43-100.0), sensitivity of 97.33% ± 0.06% (95% CI, 83.33-100.0), specificity of 84.6% ± 0.10% (95% CI, 71.43-100.0), AUROC curve of 99.67% ± 0.02% (95% CI, 95.63-100.0), and AUPRC of 99.65% ± 0.02% (95% CI, 94.90-100.0). Conclusions: Incorporating both modalities improves the performance of automated diagnosis of MS, showcasing the potential of utilizing IR-SLO as a complementary tool alongside OCT. Translational Relevance: Should the results of our proposed bimodal model be validated in future work with larger and more diverse datasets, diagnosis of MS based on both OCT and IR-SLO can be reliably integrated into routine clinical practice.


Asunto(s)
Esclerosis Múltiple , Redes Neurales de la Computación , Oftalmoscopía , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Esclerosis Múltiple/diagnóstico por imagen , Esclerosis Múltiple/patología , Esclerosis Múltiple/diagnóstico , Femenino , Oftalmoscopía/métodos , Adulto , Masculino , Curva ROC , Persona de Mediana Edad , Aprendizaje Automático , Rayos Infrarrojos
9.
Transl Vis Sci Technol ; 13(6): 18, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38913007

RESUMEN

Purpose: To assess longitudinal reproducibility of metrics of foveal density (peak cone density [PCD], cone density centroid [CDC], and 80th percentile centroid area) in participants with normal vision. Methods: Participants (n = 19; five male and 14 female) were imaged at two time points (average interval of 3.2 years) using an adaptive optics scanning light ophthalmoscope (AOSLO). Foveally centered regions of interest (ROIs) were extracted from AOSLO montages. Cone coordinate matrices were semiautomatically derived for each ROI, and cone mosaic metrics were calculated. Results: On average, there were no significant changes in cone mosaic metrics between visits. The average ± SD PCD was 187,000 ± 20,000 cones/mm2 and 189,000 ± 21,700 cones/mm2 for visits 1 and 2, respectively (P = 0.52). The average ± SD density at the CDC was 183,000 ± 19,000 cones/mm2 and 184,000 ± 20,800 cones/mm2 for visits 1 and 2, respectively (P = 0.78). The average ± SD 80th percentile isodensity contour area was 15,400 ± 1800 µm2 and 15,600 ± 1910 µm2 for visits 1 and 2, respectively (P = 0.57). Conclusions: Foveal cone mosaic density metrics were highly reproducible in the cohort examined here, although further study is required in more diverse populations. Translational Relevance: Determination of the normative longitudinal changes in foveal cone topography is key for evaluating longitudinal measures of foveal cone topography in patients with progressive retinal dystrophies.


Asunto(s)
Fóvea Central , Células Fotorreceptoras Retinianas Conos , Humanos , Masculino , Fóvea Central/diagnóstico por imagen , Femenino , Adulto , Reproducibilidad de los Resultados , Persona de Mediana Edad , Recuento de Células , Adulto Joven , Oftalmoscopía/métodos , Tomografía de Coherencia Óptica/métodos , Agudeza Visual/fisiología
10.
Sci Rep ; 14(1): 13450, 2024 06 11.
Artículo en Inglés | MEDLINE | ID: mdl-38862584

RESUMEN

This study tested if a high-resolution, multi-modal, multi-scale retinal imaging instrument can provide novel information about structural abnormalities in vivo. The study examined 11 patients with very mild to moderate non-proliferative diabetic retinopathy (NPDR) and 10 healthy subjects using fundus photography, optical coherence tomography (OCT), OCT angiography (OCTA), adaptive optics scanning laser ophthalmoscopy (AO-SLO), adaptive optics OCT and OCTA (AO-OCT(A)). Of 21 eyes of 11 patients, 11 had very mild NPDR, 8 had mild NPDR, 2 had moderate NPDR, and 1 had no retinopathy. Using AO-SLO, capillary looping, inflections and dilations were detected in 8 patients with very mild or mild NPDR, and microaneurysms containing hyperreflective granular elements were visible in 9 patients with mild or moderate NPDR. Most of the abnormalities were seen to be perfused in the corresponding OCTA scans while a few capillary loops appeared to be occluded or perfused at a non-detectable flow rate, possibly because of hypoperfusion. In one patient with moderate NPDR, non-perfused capillaries, also called ghost vessels, were identified by alignment of corresponding en face AO-OCT and AO-OCTA images. The combination of multiple non-invasive imaging methods could identify prominent microscopic abnormalities in diabetic retinopathy earlier and more detailed than conventional fundus imaging devices.


Asunto(s)
Capilares , Retinopatía Diabética , Oftalmoscopía , Tomografía de Coherencia Óptica , Humanos , Tomografía de Coherencia Óptica/métodos , Retinopatía Diabética/diagnóstico por imagen , Retinopatía Diabética/patología , Femenino , Masculino , Oftalmoscopía/métodos , Persona de Mediana Edad , Capilares/diagnóstico por imagen , Capilares/patología , Adulto , Vasos Retinianos/diagnóstico por imagen , Vasos Retinianos/patología , Anciano , Angiografía con Fluoresceína/métodos
11.
Acta Neuropathol Commun ; 12(1): 109, 2024 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-38943220

RESUMEN

The relationship between amyloidosis and vasculature in cognitive impairment and Alzheimer's disease (AD) pathogenesis is increasingly acknowledged. We conducted a quantitative and topographic assessment of retinal perivascular amyloid plaque (AP) distribution in individuals with both normal and impaired cognition. Using a retrospective dataset of scanning laser ophthalmoscopy fluorescence images from twenty-eight subjects with varying cognitive states, we developed a novel image processing method to examine retinal peri-arteriolar and peri-venular curcumin-positive AP burden. We further correlated retinal perivascular amyloidosis with neuroimaging measures and neurocognitive scores. Our study unveiled that peri-arteriolar AP counts surpassed peri-venular counts throughout the entire cohort (P < 0.0001), irrespective of the primary, secondary, or tertiary vascular branch location, with a notable increase among cognitively impaired individuals. Moreover, secondary branch peri-venular AP count was elevated in the cognitively impaired (P < 0.01). Significantly, peri-venular AP count, particularly in secondary and tertiary venules, exhibited a strong correlation with clinical dementia rating, Montreal cognitive assessment score, hippocampal volume, and white matter hyperintensity count. In conclusion, our exploratory analysis detected greater peri-arteriolar versus peri-venular amyloidosis and a marked elevation of amyloid deposition in secondary branch peri-venular regions among cognitively impaired subjects. These findings underscore the potential feasibility of retinal perivascular amyloid imaging in predicting cognitive decline and AD progression. Larger longitudinal studies encompassing diverse populations and AD-biomarker confirmation are warranted to delineate the temporal-spatial dynamics of retinal perivascular amyloid deposition in cognitive impairment and the AD continuum.


Asunto(s)
Amiloidosis , Atrofia , Disfunción Cognitiva , Hipocampo , Humanos , Masculino , Femenino , Anciano , Disfunción Cognitiva/patología , Disfunción Cognitiva/diagnóstico por imagen , Hipocampo/patología , Hipocampo/diagnóstico por imagen , Atrofia/patología , Amiloidosis/patología , Amiloidosis/diagnóstico por imagen , Anciano de 80 o más Años , Estudios Retrospectivos , Persona de Mediana Edad , Placa Amiloide/patología , Placa Amiloide/diagnóstico por imagen , Enfermedades de la Retina/patología , Enfermedades de la Retina/diagnóstico por imagen , Vasos Retinianos/patología , Vasos Retinianos/diagnóstico por imagen , Oftalmoscopía/métodos
12.
J Vis ; 24(6): 2, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38833255

RESUMEN

The spectral locus of unique yellow was determined for flashes of different sizes (<11 arcmin) and durations (<500 ms) presented in and near the fovea. An adaptive optics scanning laser ophthalmoscope was used to minimize the effects of higher-order aberrations during simultaneous stimulus delivery and retinal imaging. In certain subjects, parafoveal cones were classified as L, M, or S, which permitted the comparison of unique yellow measurements with variations in local L/M ratios within and between observers. Unique yellow shifted to longer wavelengths as stimulus size or duration was reduced. This effect is most pronounced for changes in size and more apparent in the fovea than in the parafovea. The observed variations in unique yellow are not entirely predicted from variations in L/M ratio and therefore implicate neural processes beyond photoreception.


Asunto(s)
Fóvea Central , Estimulación Luminosa , Células Fotorreceptoras Retinianas Conos , Humanos , Estimulación Luminosa/métodos , Células Fotorreceptoras Retinianas Conos/fisiología , Fóvea Central/fisiología , Percepción de Color/fisiología , Retina/fisiología , Adulto , Oftalmoscopía/métodos
13.
Opt Lett ; 49(9): 2489-2492, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38691751

RESUMEN

Point scanning retinal imaging modalities, including confocal scanning light ophthalmoscopy (cSLO) and optical coherence tomography, suffer from fixational motion artifacts. Fixation targets, though effective at reducing eye motion, are infeasible in some applications (e.g., handheld devices) due to their bulk and complexity. Here, we report on a cSLO device that scans the retina in a spiral pattern under pseudo-visible illumination, thus collecting image data while simultaneously projecting, into the subject's vision, the image of a bullseye, which acts as a virtual fixation target. An imaging study of 14 young adult volunteers was conducted to compare the fixational performance of this technique to that of raster scanning, with and without a discrete inline fixation target. Image registration was used to quantify subject eye motion; a strip-wise registration method was used for raster scans, and a novel, to the best of our knowledge, ring-based method was used for spiral scans. Results indicate a statistically significant reduction in eye motion by the use of spiral scanning as compared to raster scanning without a fixation target.


Asunto(s)
Fijación Ocular , Oftalmoscopía , Retina , Humanos , Retina/diagnóstico por imagen , Fijación Ocular/fisiología , Oftalmoscopía/métodos , Adulto , Adulto Joven , Movimientos Oculares
14.
Invest Ophthalmol Vis Sci ; 65(5): 27, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38758638

RESUMEN

Purpose: To demonstrate the first near-infrared adaptive optics fluorescence lifetime imaging ophthalmoscopy (NIR-AOFLIO) measurements in vivo of the human retinal pigment epithelial (RPE) cellular mosaic and to visualize lifetime changes at different retinal eccentricities. Methods: NIR reflectance and autofluorescence were captured using a custom adaptive optics scanning light ophthalmoscope in 10 healthy subjects (23-64 years old) at seven eccentricities and in two eyes with retinal abnormalities. Repeatability was assessed across two visits up to 8 weeks apart. Endogenous retinal fluorophores and hydrophobic whole retinal extracts of Abca4-/- pigmented and albino mice were imaged to probe the fluorescence origin of NIR-AOFLIO. Results: The RPE mosaic was resolved at all locations in five of seven younger subjects (<35 years old). The mean lifetime across near-peripheral regions (8° and 12°) was longer compared to near-foveal regions (0° and 2°). Repeatability across two visits showed moderate to excellent correlation (intraclass correlation: 0.88 [τm], 0.75 [τ1], 0.65 [τ2], 0.98 [a1]). The mean lifetime across drusen-containing eyes was longer than in age-matched healthy eyes. Fluorescence was observed in only the extracts from pigmented Abca4-/- mouse. Conclusions: NIR-AOFLIO was repeatable and allowed visualization of the RPE cellular mosaic. An observed signal in only the pigmented mouse extract infers the fluorescence signal originates predominantly from melanin. Variations observed across the retina with intermediate age-related macular degeneration suggest NIR-AOFLIO may act as a functional measure of a biomarker for in vivo monitoring of early alterations in retinal health.


Asunto(s)
Oftalmoscopía , Imagen Óptica , Epitelio Pigmentado de la Retina , Humanos , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Epitelio Pigmentado de la Retina/metabolismo , Oftalmoscopía/métodos , Adulto , Persona de Mediana Edad , Animales , Femenino , Ratones , Masculino , Adulto Joven , Imagen Óptica/métodos , Reproducibilidad de los Resultados , Rayos Infrarrojos , Transportadoras de Casetes de Unión a ATP/genética , Transportadoras de Casetes de Unión a ATP/metabolismo , Angiografía con Fluoresceína/métodos
15.
Sci Rep ; 14(1): 8339, 2024 04 09.
Artículo en Inglés | MEDLINE | ID: mdl-38594294

RESUMEN

Choroideremia (CHM) is an X-linked retinal degeneration leading to loss of the photoreceptors, retinal pigment epithelium (RPE), and choroid. Adaptive optics optoretinography is an emerging technique for noninvasive, objective assessment of photoreceptor function. Here, we investigate parafoveal cone function in CHM using adaptive optics optoretinography and compare with cone structure and clinical assessments of vision. Parafoveal cone mosaics of 10 CHM and four normal-sighted participants were imaged with an adaptive optics scanning light ophthalmoscope. While acquiring video sequences, a 2 s 550Δ10 nm, 450 nW/deg2 stimulus was presented. Videos were registered and the intensity of each cone in each frame was extracted, normalized, standardized, and aggregated to generate the population optoretinogram (ORG) over time. A gamma-pdf was fit to the ORG and the peak was extracted as ORG amplitude. CHM ORG amplitudes were compared to normal and were correlated with bound cone density, ellipsoid zone to RPE/Bruch's membrane (EZ-to-RPE/BrM) distance, and foveal sensitivity using Pearson correlation analysis. ORG amplitude was significantly reduced in CHM compared to normal (0.22 ± 0.15 vs. 1.34 ± 0.31). In addition, CHM ORG amplitude was positively correlated with cone density, EZ-to-RPE/BrM distance, and foveal sensitivity. Our results demonstrate promise for using ORG as a biomarker of photoreceptor function.


Asunto(s)
Coroideremia , Humanos , Oftalmoscopía/métodos , Células Fotorreceptoras Retinianas Conos , Coroides , Epitelio Pigmentado de la Retina/diagnóstico por imagen , Tomografía de Coherencia Óptica/métodos
16.
Vet Rec ; 194(9): e4088, 2024 05 04.
Artículo en Inglés | MEDLINE | ID: mdl-38637964

RESUMEN

BACKGROUND: Ophthalmoscopy is a valuable tool in clinical practice. We report the use of a novel smartphone-based handheld device for visualisation and photo-documentation of the ocular fundus in veterinary medicine. METHODS: Selected veterinary patients of a referral ophthalmology service were included if one or both eyes had clear ocular media, allowing for examination of the fundus. Following pharmacological mydriasis, fundic images were obtained with a handheld fundus camera (Volk VistaView). For comparison, the fundus of a subset of animals was also imaged with a veterinary-specific fundus camera (Optomed Smartscope VET2). RESULTS: The large field of view achieved by the Volk VistaView allowed for rapid and thorough observation of the ocular fundus in animals, providing a tool to visualise and record common pathologies of the posterior segment. Captured fundic images were sometimes overexposed, with the tapetal fundus artificially appearing hyperreflective when using the Volk VistaView camera, a finding that was less frequent when activating a 'veterinary mode' that reduced the sensitivity of the camera's sensor. The Volk VistaView compared well with the Optomed Smartscope VET2. LIMITATION: The main study limitation was the small sample size. CONCLUSIONS: The Volk VistaView camera was easy to use and provided good-quality fundic images in veterinary patients with healthy or diseased eyes, offering a wide field of view that was ideal for screening purposes.


Asunto(s)
Enfermedades de la Retina , Teléfono Inteligente , Medicina Veterinaria , Animales , Enfermedades de la Retina/veterinaria , Enfermedades de la Retina/diagnóstico , Medicina Veterinaria/instrumentación , Oftalmoscopía/veterinaria , Oftalmoscopía/métodos , Fondo de Ojo , Fotograbar/veterinaria , Fotograbar/instrumentación , Perros , Enfermedades de los Perros/diagnóstico , Gatos
17.
Invest Ophthalmol Vis Sci ; 65(4): 27, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38630675

RESUMEN

Purpose: Fluorescence lifetime ophthalmoscopy (FLIO) is an emerging clinical modality that could provide biomarkers of retinal health beyond fluorescence intensity. Adaptive optics (AO) ophthalmoscopy provides the confocality to measure fluorescence lifetime (FL) primarily from the retinal pigment epithelium (RPE) whereas clinical FLIO has greater influence from fluorophores in the inner retina and lens. Adaptive optics fluorescence lifetime ophthalmoscopy (AOFLIO) measures of FL in vivo could provide insight into RPE health at different stages of disease. In this study, we assess changes in pentosan polysulfate sodium (PPS) toxicity, a recently described toxicity that has clinical findings similar to advanced age-related macular degeneration. Methods: AOFLIO was performed on three subjects with PPS toxicity (57-67 years old) and six age-matched controls (50-64 years old). FL was analyzed with a double exponential decay curve fit and with phasor analysis. Regions of interest (ROIs) were subcategorized based on retinal features on optical coherence tomography (OCT) and compared to age-matched controls. Results: Twelve ROIs from PPS toxicity subjects met the threshold for analysis by curve fitting and 15 ROIs met the threshold for phasor analysis. Subjects with PPS toxicity had prolonged FL compared to age-matched controls. ROIs of RPE degeneration had the longest FLs, with individual pixels extending longer than 900 ps. Conclusions: Our study shows evidence that AOFLIO can provide meaningful information in outer retinal disease beyond what is obtainable from fluorescence intensity alone. More studies are needed to determine the prognostic value of AOFLIO.


Asunto(s)
Degeneración Retiniana , Epitelio Pigmentado de la Retina , Humanos , Persona de Mediana Edad , Anciano , Poliéster Pentosan Sulfúrico , Retina , Oftalmoscopía/métodos , Tomografía de Coherencia Óptica/métodos , Angiografía con Fluoresceína/métodos
18.
Retina ; 44(4): 659-668, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38531059

RESUMEN

PURPOSE: Choroideremia is an X-linked inherited retinal degeneration involving the choriocapillaris, retinal pigment epithelium, and photoreceptors. Adaptive optics scanning light ophthalmoscopy allows visualization of retinal structure at the level of individual cells and is well poised to provide insight into the pathophysiologic mechanisms underpinning the retinal degeneration in choroideremia. METHODS: Foveal adaptive optics scanning light ophthalmoscopy images of 102 eyes of 54 individuals with choroideremia were analyzed. Measures were compared with those from standard clinical imaging. Visual acuity was also measured and compared with quantitative foveal metrics. RESULTS: The 3 distinct phenotypes observed were: relatively normal (5 eyes, 4 individuals), spiderweb (9 eyes, 7 individuals), and salt and pepper (87 eyes, 47 individuals). Peak cone density (86 eyes of 51 individuals) was significantly lower in choroideremia than in healthy retinas (P < 0.0001, range: 29,382-157,717 cones/mm2). Peak cone density was significantly related to extent of retained ellipsoid zone on en face optical coherence tomography (r2 = 0.47, P = 0.0009) and inversely related to visual acuity (r2 = 0.20, P = 0.001). CONCLUSION: Distinct phenotypes can be observed on adaptive optics scanning light ophthalmoscopy imaging in choroideremia that cannot always be discerned on standard clinical imaging. Quantitative measures on adaptive optics imaging are related to the structural and functional severity of disease.


Asunto(s)
Coroideremia , Degeneración Retiniana , Humanos , Tomografía de Coherencia Óptica/métodos , Oftalmoscopía/métodos , Células Fotorreceptoras Retinianas Conos
19.
Opt Express ; 32(3): 3031-3045, 2024 Jan 29.
Artículo en Inglés | MEDLINE | ID: mdl-38297535

RESUMEN

We propose and design a multi-stage cascaded scanning laser ophthalmoscope (SLO) for ultra-wide field (UWF), which uses conicoid mirrors, constructed by conjugation of pupil plane. The vergence uniformity and the angular magnification of a cascaded conicoid mirrors (CCM) system are analyzed recursively and optimized preliminarily to achieve high quality imaging with UWF, and the optimal system with the model eye are obtained by simulation and optimization. Two-stage and three-stage cascaded systems are designed with this method, and the formulas of beam vergence and angular magnification are obtained by theoretical derivation. As compared to the two-stage CCM system, the proposed three-stage cascaded UWF SLO has superior performance in imaging quality. Its average RMS radius of spot diagram is calculated to be 26.372 µm, close to the diffractive limit resolution. The image resolution of human retina can be up to 30 µm with 135° FOV in theory. The three-stage cascaded SLO is more suitable for UWF fundus imaging. This study will be helpful for early screening and accurate diagnosis of various diseases in the peripheral retina.


Asunto(s)
Oftalmoscopios , Retina , Humanos , Oftalmoscopía/métodos , Fondo de Ojo , Retina/diagnóstico por imagen , Rayos Láser
20.
Cesk Slov Oftalmol ; 80(2): 86-92, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38413225

RESUMEN

AIM: To clarify the possibilities and role of posterior segment imaging in patients with neurofibromatosis type I (NF1), and to show the prevalence of this disease in the pediatric population in Slovakia. MATERIAL AND METHODS: Until recently, ophthalmologic consultations in patients with NF1 were limited mainly to the observation of Lisch nodules of the iris and the presence of optic nerve glioma. However, advances in imaging capabilities have made it possible to investigate and describe new f indings concerning the ocular manifestations of this disease. Between October 2020 and November 2021, we examined the anterior and posterior segment of 76 eyes (38 children ­ 12 boys and 26 girls) with genetically confirmed NF1 gene mutation at our clinic. The age of the patients ranged from 4 to 18 years. The anterior segment was checked for the presence of Lisch nodules biomicroscopically with a slit lamp. On the posterior segment, the presence of choroidal nodules was checked by various imaging methods ­ fundus camera, infrared confocal selective laser ophthalmoscopy, MultiColor imaging, OCT, and OCT angiography. All the patients had magnetic resonance imaging performed in order to detect potential optic nerve gliomas for the purpose of diagnosis. We observed the correlation between the patients' age, presence of Lisch nodules and the presence of choroidal nodules. Eight patients also had other manifestations of the disease ­ optic nerve gliomas or microvascular changes (so-called "corkscrew" vessels). RESULTS: Out of 38 patients, Lisch iris nodules were present in 20 patients (53%) and choroidal nodules in 24 patients (63%). There was no positive correlation between the presence of these two manifestations within the same patient or eye, but there is a clear correlation between the presence of choroidal nodules and patient age. CONCLUSION: The results suggest that a previously unknown ocular manifestation of neurofibromatosis type I, namely choroidal nodules, has a higher prevalence than Lisch nodules also in the pediatric population and can be easily visualized using various imaging modalities. It will be important to include follow-up observation of this finding among the standard controls for ocular findings in NF1, and it will be very interesting to correlate this f inding with the exact NF1 mutation


Asunto(s)
Neurofibromatosis 1 , Glioma del Nervio Óptico , Masculino , Femenino , Humanos , Niño , Preescolar , Adolescente , Neurofibromatosis 1/complicaciones , Coroides/patología , Oftalmoscopía/métodos , Imagen Multimodal
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...