Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 705
Filtrar
1.
J Vet Diagn Invest ; 36(4): 490-497, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38742388

RESUMEN

Telepathology, as a subset of teleconsulting, is pathology interpretation performed at a distance. Telepathology is not a new phenomenon, but since ~2015, significant advances in information technology and telecommunications coupled with the pandemic have led to unprecedented sophistication, accessibility, and use of telepathology in human and veterinary medicine. Furthermore, telepathology can connect veterinary practices to distant laboratories and provide support for underserved animals and communities. Through our scoping review, we provide an overview of how telepathology is being used in veterinary medicine, identify gaps in the literature, and highlight future areas of research and service development. We searched MEDLINE, CAB Abstracts, and the gray literature, and included all relevant literature. Despite the widespread use of digital microscopy in large veterinary diagnostic laboratories, we identified a paucity of literature describing the use of telepathology in veterinary medicine, with a significant gap in studies addressing the validation of whole-slide imaging for primary diagnosis. Underutilization of telepathology to support postmortem examinations conducted in the field was also identified, which indicates a potential area for service development. The use of telepathology is increasing in veterinary medicine, and pathologists must keep pace with the changing technology, ensure the validation of innovative technologies, and identify novel uses to advance the profession.


Asunto(s)
Telepatología , Medicina Veterinaria , Animales , Medicina Veterinaria/métodos , Patología Veterinaria/métodos
4.
Vet Clin Pathol ; 53 Suppl 1: 60-64, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37496234

RESUMEN

BACKGROUND: A recent study identified 7 probability ranges used by clinical pathologists and associated qualitative terms used in cytology reports. Clinicians and clinical pathologists agreed that limiting the number of terms could help enhance communication between clinical pathologists and clinicians. However, the preferred terms for each range remain undetermined. OBJECTIVE: We sought to determine a single term for each probability range that could be adopted by the global veterinary clinical pathology community. METHOD: Clinical pathologists responded to a survey invitation distributed via the specialty listserv. Clinical pathologists were asked to rank previously identified terms for each probability range from "most preferred" to "least preferred." An alternative term could be proposed if they preferred a term not included in the question. The preferences were summed by rank. Where first choice ranks were within 20% of each other, the 1st and 2nd choices were added. The term with the highest counts was chosen to represent the probability range. RESULTS: The highest-ranking terms corresponding to the probability ranges of 0%-20%, 20%-50%, 50%-65%, 65%-75%, 75%-85%, 85%-95%, and 95%-100% were "no evidence for," "cannot rule out," "possible," "suspicious for," "most likely," "most consistent with," and no modifier, respectively. CONCLUSIONS: We have sampled clinical pathologists across the globe to rank terms in cytology reports associated with previously identified probability ranges to identify single qualitative terms for which there was the most agreement between clinicians and clinical pathologists. Our study provides the foundation for standardizing and limiting probability-modifying terms to improve communication with clinicians.


Asunto(s)
Patología Clínica , Patología Veterinaria , Animales , Humanos , Patólogos , Encuestas y Cuestionarios , Probabilidad
5.
Vet Clin Pathol ; 53 Suppl 1: 7-23, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-36609689

RESUMEN

BACKGROUND: The 2019 ASVCP Education Committee Forum for Discussion, presented at the annual ASVCP/ACVP meeting, identified a need to develop recommendations for teaching laboratory quality management principles in veterinary clinical pathology residency training programs. OBJECTIVES: To present a competency-based framework for teaching laboratory quality management principles in veterinary clinical pathology residency training programs, including entrustable professional activities (EPAs), domains of competence, individual competencies, and learning outcomes. METHODS: A joint subcommittee of the ASVCP Quality Assurance and Laboratory Standards (QALS) and Education Committees executed this project. A draft guideline version was reviewed by the ASVCP membership and shared with selected ACVP committees in early 2022, and a final version was voted upon by the full QALS and Education Committees in late 2022. RESULTS: Eleven domains of competence with relevant individual competencies were identified. In addition, suggested learning outcomes and resource lists were developed. Domains and individual competencies were mapped to six EPAs. CONCLUSIONS: This guideline presents a framework for teaching principles of laboratory quality management in veterinary clinical pathology residency training programs and was designed to be comprehensive yet practical. Guidance on pedagogical terms and possible routes of implementation are included. Recommendations herein aim to improve and support resident training but may require gradual implementation, as programs phase in necessary expertise and resources. Future directions include the development of learning milestones and assessments and consideration of how recommendations intersect with the American College of Veterinary Pathologists training program accreditation and certifying examination.


Asunto(s)
Internado y Residencia , Patología Clínica , Patología Veterinaria , Estados Unidos , Animales , Acreditación , Laboratorios
7.
Vet Pathol ; 60(6): 721, 2023 11.
Artículo en Inglés | MEDLINE | ID: mdl-37846571
8.
9.
Vet Pathol ; 60(1): 5, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-37452779
11.
Vet Pathol ; 60(3): 289-290, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37129102
14.
Vet Pathol ; 60(2): 157, 2023 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-36840385
20.
Vet Clin Pathol ; 51(4): 565-576, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-35922888

RESUMEN

BACKGROUND: Quality control (QC) validation is an important step in the laboratory harmonization process. This includes the application of statistical QC requirements, procedures, and control rules to identify and maintain ongoing stable analytical performance. This provides confidence in the production of patient results that are suitable for clinical interpretation across a network of veterinary laboratories. OBJECTIVES: To determine that a higher probability of error detection (Ped ) and lower probability of false rejection (Pfr ) using a simple control rule and one level of quality control material (QCM) could be achieved using observed analytical performance than by using the manufacturer's acceptable ranges for QCM on the Sysmex XT-2000iV hematology analyzers for veterinary use. We also determined whether Westgard Sigma Rules could be sufficient to monitor and maintain a sufficiently high level of analytical performance to support harmonization. METHODS: EZRules3 was used to investigate candidate QC rules and determine the Ped and Pfr of manufacturer's acceptable limits and also analyzer-specific observed analytical performance for each of the six Sysmex analyzers within our laboratory system using the American Society of Veterinary Clinical Pathology (ASVCP)-recommended or internal expert opinion quality goals (expressed as total allowable error, TEa ) as the quality requirement. The internal expert quality goals were generated by consensus of the Quality, Education, Planning, and Implementation (QEPI) group comprised of five clinical pathologists and seven laboratory technicians and managers. Sigma metrics, which are a useful monitoring tool and can be used in conjunction with Westgard Sigma Rules, were also calculated. RESULTS: The QC validation using the manufacturer's acceptable limits for analyzer 1 showed only 3/10 measurands reached acceptable Ped for veterinary laboratories (>0.85). For QC validation based on observed analyzer performance, the Ped was >0.94 using a 1-2.5s QC rule for the majority of observations (57/60) across the group of analyzers at the recommended TEa . We found little variation in Pfr between manufacturer acceptable limits and individual analyzer observed performance as this is a characteristic of the rule used, not the analyzer performance. CONCLUSIONS: An improved probability of error detection and probability of false rejection using a 1-2.5s QC rule for individual analyzer QC was achieved compared with the use of the manufacturers' acceptable limits for hematology in veterinary laboratories. A validated QC rule (1-2.5s) in conjunction with sigma metrics (>5.5), desirable bias, and desirable CV based on biologic variation was successful to evaluate stable analytical performance supporting continued harmonization across the network of analyzers.


Asunto(s)
Hematología , Patología Veterinaria , Control de Calidad , Animales , Hematología/instrumentación , Hematología/métodos , Hematología/normas , Laboratorios , Patología Veterinaria/instrumentación , Patología Veterinaria/métodos , Patología Veterinaria/normas , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...