Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Biosens Bioelectron ; 151: 111871, 2020 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-31999569

RESUMEN

A rapid and ultrasensitive biosensing method based on fiber optic nanogold-linked immunosorbent assay is reported. The method employs an immobilized capture probe on the fiber core surface of an optical fiber and a detection probe conjugated to gold nanoparticles (AuNPs) in a solution. Introduction of a sample containing an analyte and the detection probe into a biosensor chip leads to the formation of a sandwich-like complex of capture probe-analyte-detection probe on the fiber core surface, through which nanoplasmonic absorption of the fiber optic evanescent wave occurs. The performance of this method has been evaluated by its application to the detection of procalcitonin (PCT), an important biomarker for sepsis. In this study, anti-PCT capture antibody is functionalized on an unclad segment of an optical fiber to yield a fiber sensor and anti-PCT detection antibody is conjugated to AuNPs to afford nanoplasmonic probes. The method provides a wide linear response range from 1 pg/mL to 100 ng/mL (5 orders) and an extremely low limit of detection of 95 fg/mL (7.3 fM) for PCT. In addition, the method shows a good correlation in determining PCT in blood plasma with the clinically validated electrochemiluninescent immunoassay. Furthermore, the method is quick (analysis time ≤15 min), requires low-cost instrumentation and sensor chips, and is also potentially applicable to the detection of many other biomarkers.


Asunto(s)
Técnicas Biosensibles , Tecnología de Fibra Óptica , Nanopartículas del Metal/química , Polipéptido alfa Relacionado con Calcitonina/aislamiento & purificación , Humanos , Inmunoensayo , Inmunoadsorbentes/química , Fibras Ópticas , Polipéptido alfa Relacionado con Calcitonina/química
2.
Biosens Bioelectron ; 144: 111676, 2019 Nov 01.
Artículo en Inglés | MEDLINE | ID: mdl-31522100

RESUMEN

The point of fabricating ultrasensitive electrochemiluminescence (ECL)-based biosensors should be focused on how to maintain high immune recognition of antigens by antibodies in whole process. That is not effortless due to the structure of the protein can be destroyed root in toxic nanocarriers, excessive cyclic potential and superoxide radicals in coreactant, all of which can lead to reduce the bioactivity of antigen and antibody. In this work, the effect of negative voltage and divers coreactant on protein bioactivity were verified. Based on that, a motivated ECL biosensor with good biocompatibility was fabricated for procalcitonin (PCT) detection using Au nanoclusters (Au NCs) as low-potential cathodic luminophor and K2S2O8 as non-toxic coreactant, respectively. Besides, highly-branched Cu2O was utilized to catalyze K2S2O8 and produce more radical anion SO4•-, which can oxidize Au NCs•- to generate more high-energy-state Au NCs*, thus doubling the ECL intensity to meet the requirements of trace analysis. In addition, protein A (PA) as specific antibody capturer was employed to bind the Fc region of anti-PCT in an orientated way, further maintaining the physiological activity of antibody. As expected, all strategies undoubtedly practically improved the immune recognition of the biosensor and reduced the detection limit to 2.90 fg/mL.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Nanopartículas del Metal/química , Polipéptido alfa Relacionado con Calcitonina/aislamiento & purificación , Anticuerpos/química , Antígenos/química , Catálisis , Oro/química , Límite de Detección , Mediciones Luminiscentes , Compuestos de Potasio/química , Polipéptido alfa Relacionado con Calcitonina/química , Sulfatos/química
3.
ACS Nano ; 13(8): 8609-8617, 2019 08 27.
Artículo en Inglés | MEDLINE | ID: mdl-31276361

RESUMEN

Timely diagnosis of acute diseases improves treatment outcomes and saves lives, but it requires fast and precision quantification of biomarkers. Here, we report a time-resolved digital immunoassay based on plasmonic imaging of binding of single nanoparticles to biomarkers captured on a sensor surface. The real-time and high contrast of plasmonic imaging lead to fast and precise counting of the individual biomarkers over a wide dynamic range. We demonstrated the detection principle, evaluated the performance of the method using procalcitonin (PCT) as an example, and achieved a limit of detection of ∼2.8 pg/mL, dynamic range of 4.2-12500 pg/mL, for a total detection time of ∼25 min.


Asunto(s)
Biomarcadores/química , Técnicas Biosensibles , Nanopartículas/química , Polipéptido alfa Relacionado con Calcitonina/aislamiento & purificación , Humanos , Inmunoensayo/métodos , Límite de Detección , Imagen Molecular/métodos , Polipéptido alfa Relacionado con Calcitonina/química
4.
Biosens Bioelectron ; 126: 543-550, 2019 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-30481668

RESUMEN

In this study, we established an ultrasensitive electrochemical immunosensor based on the gold nanoparticles-enhanced tyramide signal amplification (AuNPs-TSA) for the detection of procalcitonin (PCT, for discriminating bacterial infections from nonbacterial infections). Firstly, a facilely prepared, well-conducting reduced graphene oxide nanosheets/GNP (rGO-AuNPs) nanocomposite was synthesized and immobilized on the electrode surface to absorb more capture antibodies (Ab1). Next another nanocomposite, acting as a signal tool, was modified with detection antibody (Ab2) and horseradish peroxidase (HRP), and then backfilled by bovine serum albumin (BSA). Because a single AuNP is able to load multiple HRPs and BSAs, a number of tyramine labeled biotins (T-B) could be deposited on the proteins adhering to the surface of AuNPs. Moreover, the high affinity between streptavidin (SA) and biotins significantly increases the loading of streptavidin labeled horseradish peroxidase (SA-HRP). The amplification system which was based on the two nanocomposites mentioned above, effectively amplified the electric current signals. This immunosensor exhibits a wide dynamic detection range from 0.05 ng mL-1 to 100 ng mL-1 and with an ultralow detection limit of 0.1 pg mL-1. We have successfully utilized this immunosensor to quantify the concentration of PCT in human serum samples, and the results suggest its potential use in clinical application.


Asunto(s)
Técnicas Biosensibles , Infecciones/diagnóstico , Polipéptido alfa Relacionado con Calcitonina/aislamiento & purificación , Oro/química , Grafito/química , Humanos , Infecciones/microbiología , Nanopartículas del Metal/química , Nanocompuestos/química , Polipéptido alfa Relacionado con Calcitonina/química , Polipéptido alfa Relacionado con Calcitonina/inmunología , Tiramina/química
5.
Blood Purif ; 46(2): 153-159, 2018.
Artículo en Inglés | MEDLINE | ID: mdl-29705804

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the impact of continuous veno-venous hemodialysis (CVVHD) using high cutoff (HCO) hemofilters on the removal of procalcitonin (PCT), and other inflammatory markers in the treatment of patients during septic shock with acute kidney injury (AKI). MATERIALS AND METHODS: Thirty-six patients with septic shock and AKI were included in the study. Before and after the 24-h HCO-CVVHD, PCT, native C-reactive protein (CRP) and cytokines (interleukin-1ß, interleukin-6, interleukin-12, interleukin-17, tumor necrosis factor-α) in serum and effluent were assessed. RESULTS: After the HCO-CVVHD serum concentrations of PCT, CRP and selected cytokines were significantly lower. The decrease in PCT was bigger than in CRP (p = 0.007). The change in PCT concentration was significantly influenced by PCT and IL-17 clearances (R2 = 0.525; p < 0.001). CONCLUSION: In contrast to the native CRP, monitoring of PCT during HCO-CVVHD is less useful because it reflects the clearance of this marker and anti-inflammatory effectiveness of the method.


Asunto(s)
Lesión Renal Aguda/complicaciones , Citocinas/aislamiento & purificación , Hemofiltración/métodos , Polipéptido alfa Relacionado con Calcitonina/aislamiento & purificación , Diálisis Renal/instrumentación , Sepsis/complicaciones , Anciano , Proteína C-Reactiva/análisis , Femenino , Humanos , Masculino , Persona de Mediana Edad , Polipéptido alfa Relacionado con Calcitonina/análisis , Diálisis Renal/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...