Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.467
Filtrar
1.
Sci Rep ; 14(1): 18014, 2024 08 03.
Artículo en Inglés | MEDLINE | ID: mdl-39097612

RESUMEN

Cerium oxide nanoparticles are known for their antibacterial effects resulting from Ce3+ to Ce4+ conversion. Application of such cerium oxide nanoparticles in dentistry has been previously considered but limited due to deterioration of mechanical properties. Hence, this study aimed to examine mesoporous silica (MCM-41) coated with cerium oxide nanoparticles and evaluate the antibacterial effects and mechanical properties when applied to dental composite resin. Cerium oxide nanoparticles were coated on the MCM-41 surface using the sol-gel method by adding cerium oxide nanoparticle precursor to the MCM-41 dispersion. The samples were tested for antibacterial activity against Streptococcus mutans via CFU and MTT assays. The mechanical properties were assessed by flexural strength and depth of cure according to ISO 4049. Data were analyzed using a t-test, one-way ANOVA, and Tukey's post-hoc test (p = 0.05). The experimental group showed significantly increased antibacterial properties compared to the control groups (p < 0.005). The flexural strength exhibited a decreasing trend as the amount of cerium oxide nanoparticle-coated MCM-41 increased. However, the flexural strength and depth of cure values of the silane group met the ISO 4049 standard. Antibacterial properties increased with increasing amounts of cerium oxide nanoparticles. Although the mechanical properties decreased, silane treatment overcame this drawback. Hence, the cerium oxide nanoparticles coated on MCM-41 may be used for dental resin composite.


Asunto(s)
Antibacterianos , Cerio , Resinas Compuestas , Nanopartículas , Dióxido de Silicio , Streptococcus mutans , Cerio/química , Cerio/farmacología , Dióxido de Silicio/química , Antibacterianos/farmacología , Antibacterianos/química , Resinas Compuestas/química , Resinas Compuestas/farmacología , Streptococcus mutans/efectos de los fármacos , Nanopartículas/química , Resinas Acrílicas/química , Ensayo de Materiales , Poliuretanos/química , Poliuretanos/farmacología , Resistencia Flexional , Porosidad
2.
Orthod Fr ; 95(2): 169-175, 2024 08 06.
Artículo en Francés | MEDLINE | ID: mdl-39106191

RESUMEN

Introduction: The aligner is a thermoformed plastic device composed of various chemical components: polyurethane, polyethylene terephthalate glycol, polypropylene… All these plastics must be sufficiently resistant to abrasion and translucent for aesthetic purposes, but their solubility to salivary enzymes, insertion-disinsertion fatigue and recyclability vary according to material. From an orthodontic point of view, they must facilitate tooth movement. However, their behavior differs from that of orthodontic archwires: their Young's modulus, resilience and unloading curve are distinct, resulting in mechanical properties that fall significantly below the orthodontic requirements of multi-bracket systems. Objective: The aim of this article was to review the chemical composition, recycling and mechanical properties of aligners, and to put them into perspective with therapeutic indications. Materials and Methods: Literature data were approximated to orthodontic needs. Results: Neither plastic nor direct printing can match the mechanical properties of our archwires or the procedures of a reliable vestibular multi-attachment appliance. Discussion: Aligners remain an interesting tool in targeted indications.


Introduction: L'aligneur est un dispositif en plastique thermoformé dont la composition chimique est diverse : polyuréthane, polyéthylène téréphtalate glycol, polypropylène… Tous ces plastiques doivent être suffisamment résistants à l'abrasion et translucides pour être esthétiques mais ils présentent une solubilité aux enzymes salivaires, une fatigue liée à l'insertion-désinsertion et une recyclabilité qui sont variables selon le matériau. D'un point de vue orthodontique, ils doivent permettre de déplacer les dents. Mais leur comportement ne ressemble pas à celui des arcs orthodontiques : leur module de Young, leur résilience et leur courbe de décharge en sont éloignés et confèrent des propriétés mécaniques très inférieures aux exigences orthodontiques des appareils multi-attaches. Objectif: L'objectif de l'article était de faire le point sur la composition chimique, le recyclage, les propriétés mécaniques des aligneurs et de les mettre en perspective avec les indications thérapeutiques. Matériel et méthode: Les données de la littérature sont approchées des besoins orthodontiques. Résultats: Ni le plastique, ni l'impression directe ne sont en capacité de rivaliser avec les propriétés mécaniques de nos arcs ou avec les procédures d'un appareil multi-attache vestibulaire fiables. Discussion: Les aligneurs restent un outil intéressant dans des indications ciblées.


Asunto(s)
Técnicas de Movimiento Dental , Humanos , Técnicas de Movimiento Dental/métodos , Técnicas de Movimiento Dental/instrumentación , Reciclaje/métodos , Poliuretanos/química , Alambres para Ortodoncia , Diseño de Aparato Ortodóncico , Módulo de Elasticidad , Polietilenglicoles/química , Ensayo de Materiales/métodos , Tereftalatos Polietilenos
3.
BMC Oral Health ; 24(1): 876, 2024 Aug 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095862

RESUMEN

BACKGROUND: The temperature changes, chemical agents, and brushing activity that resin composite restorations are exposed to in the oral environment can cause changes in surface roughness. In this study, the aim was to investigate in vitro the clinical one-year surface roughness changes of different types of composites (flowable or conventional) from the same companies by subjecting them to immersion in solutions, brushing, and thermal cycling procedures to simulate intraoral conditions. METHODS: Four different resin composite brands were included in the study using both their conventional (Charisma Smart, 3M Filtek Ultimate Universal, Omnichroma, Beautifil II) and flowable resin composites (Charisma Flow, 3M Filtek Ultimate Flowable, Omnichroma Flow, Beautifil Flow Plus F00), giving 4 groups with 2 types of resin composite in each. 40 samples were prepared for each group/resin type, for a total of 320 samples. After initial surface roughness measurements by a mechanical profilometer, the samples were divided into 4 subgroups (n = 10) and immersed in solutions (distilled water, tea, coffee, or wine) for 12 days. The samples were then subjected to 10,000 cycles of brushing simulation and 10,000 cycles of thermal aging. Surface roughness measurements were repeated after the procedures. For statistical analysis, the 3-way analysis of variance and the Tukey test were used (p < 0.05). RESULTS: It was concluded that composite groups and types had an effect on surface roughness at time t0 (p < 0.001). At time t1, the highest surface roughness value was obtained in the Beautifil-conventional interaction. When the surface roughness values between time t0 and t1 were compared, an increase was observed in the Beautifil II and Beautifil Flow Plus F00, while a decrease was observed in the other composite groups. CONCLUSION: Composite groups, types, and solutions had an effect on the surface roughness of resin composites. After aging procedures, it was concluded that the Beautifil group could not maintain the surface structure as it exceeded the threshold value of 0.2 µm for bacterial adhesion.


Asunto(s)
Café , Resinas Compuestas , Ensayo de Materiales , Propiedades de Superficie , Cepillado Dental , Resinas Compuestas/química , Agua/química , Factores de Tiempo , , Temperatura , Humanos , Materiales Dentales/química , Inmersión , Metacrilatos/química , Técnicas In Vitro , Poliuretanos/química , Ácidos Polimetacrílicos/química , Polietilenglicoles/química , Bisfenol A Glicidil Metacrilato
4.
ACS Appl Mater Interfaces ; 16(32): 41949-41959, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39093717

RESUMEN

Management of diabetic chronic wound exudate is a serious challenge in healthcare worldwide since it is related to the speed of diabetic wound healing. However, current foam dressings not only absorb fluid to generate swelling and compress the wound to hinder wound healing but also are very thick and less comfortable to use. Herein, a superabsorbent self-pumping ultrathin dressing is reported to accelerate diabetic wound healing by achieving superior exudate absorption and management in an ultrathin state. The self-pumping dressing is composed of a drainage layer loaded with anthocyanidin and a thermoplastic polyurethane absorbent layer embedded with superabsorbent particles. The dressing realizes the self-pumping process of unidirectional exudate draining to the absorption layer through the drainage layer without significant dressing swelling to compress the diabetic wound. The dressing is experimentally proven to unidirectionally drain excessive exudate with inflammatory factors and modulate the conversion of macrophages from M1 to M2 in diabetic wounds, thereby promoting the healing of diabetic skin ulcers faster than commercial foam dressings. Therefore, the dressing provides a new idea and novel method for accelerating diabetic skin ulcer healing.


Asunto(s)
Antocianinas , Vendajes , Diabetes Mellitus Experimental , Macrófagos , Cicatrización de Heridas , Cicatrización de Heridas/efectos de los fármacos , Animales , Macrófagos/efectos de los fármacos , Macrófagos/metabolismo , Macrófagos/inmunología , Ratones , Diabetes Mellitus Experimental/terapia , Antocianinas/química , Antocianinas/farmacología , Ratas , Masculino , Células RAW 264.7 , Poliuretanos/química
5.
Sensors (Basel) ; 24(14)2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39065977

RESUMEN

Wearable sensors, specifically microneedle sensors based on electrochemical methods, have expanded extensively with recent technological advances. Today's wearable electrochemical sensors present specific challenges: they show significant modulus disparities with skin tissue, implying possible discomfort in vivo, especially over extended wear periods or on sensitive skin areas. The sensors, primarily based on polyethylene terephthalate (PET) or polyimide (PI) substrates, might also cause pressure or unease during insertion due to the skin's irregular deformation. To address these constraints, we developed an innovative, wearable, all-fiber-structured electrochemical sensor. Our composite sensor incorporates polyurethane (PU) fibers prepared via electrospinning as electrode substrates to achieve excellent adaptability. Electrospun PU nanofiber films with gold layers shaped via thermal evaporation are used as base electrodes with exemplary conductivity and electrochemical catalytic attributes. To achieve glucose monitoring, gold nanofibers functionalized by gold nanoflakes (AuNFs) and glucose oxidase (GOx) serve as the working electrode, while Pt nanofibers and Ag/AgCl nanofibers serve as the counter and reference electrode. The acrylamide-sodium alginate double-network hydrogel synthesized on electrospun PU fibers serves as the adhesive and substance-transferring layer between the electrodes. The all-fiber electrochemical sensor is assembled layer-by-layer to form a robust structure. Given the stretchability of PU nanofibers coupled with a high specific surface area, the manufactured porous microneedle glucose sensor exhibits enhanced stretchability, superior sensitivity at 31.94 µA (lg(mM))-1 cm-2, a broad detection range (1-30 mM), and a significantly low detection limit (1 mM, S/N = 3), as well as satisfactory biocompatibility. Therefore, the novel electrochemical microneedle design is well-suited for wearable or even implantable continuous monitoring applications, thereby showing promising significant potential within the global arena of wearable medical technology.


Asunto(s)
Técnicas Biosensibles , Nanofibras , Poliuretanos , Dispositivos Electrónicos Vestibles , Humanos , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Poliuretanos/química , Nanofibras/química , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Electrodos , Oro/química , Glucosa Oxidasa/química , Glucosa/análisis
6.
Technol Cancer Res Treat ; 23: 15330338241266479, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39043036

RESUMEN

Objective: In external radiotherapy, dose boluses and compensators are used for treatment of irregular facial topography surfaces. In such cases, skewed isodose curves need to be addressed using a bolus that gives the deep dose distribution a shape adapted to the anatomical structures to be protected or irradiated. The combination of 3D modeling and printing technologies is a promising alternative to the conventional inaccurate and uncomfortable bolus fabrication technique. In this work, the proposed technologies will be used in the design and fabrication of high-performance and high-accuracy boluses that respond to the main constraints on metrology, adhesion to the patient's surface, comfort, and dose delivery. Methods: As a first phase in the implementation of the proposed solution, 3D printing materials, to be used in the fabrication of radiotherapy boluses, were selected and characterized to check how they respond to the required criteria on functionality, safety, and quality. Results: The obtained results show that among the studied materials, thermoplastic polyurethane (TPU) was found to be slightly more suitable than polylactic acid (PLA) for the fabrication of 3D printing boluses but for some kinds of treatments, PLA may be preferred despite its relative rigidity. Conclusion: In this work, procedures for dose bolus fabrication were proposed, and necessary data were obtained for some available 3D printing materials (TPU and PLA) that can be used for targeted applications. This achievement is a major step toward the final implementation of 3D modeling and printing technologies for the efficient fabrication of radiotherapy dose boluses.


Asunto(s)
Impresión Tridimensional , Dosificación Radioterapéutica , Humanos , Planificación de la Radioterapia Asistida por Computador/métodos , Poliésteres/química , Poliuretanos/química
7.
Biofabrication ; 16(4)2024 Jul 25.
Artículo en Inglés | MEDLINE | ID: mdl-38968935

RESUMEN

Three-dimensional (3D) printing is an emerging tool for creating patient-specific tissue constructs analogous to the native tissue microarchitecture. In this study, anatomically equivalent 3D nerve conduits were developed using thermoplastic polyurethane (TPU) by combining reverse engineering and material extrusion (i.e. fused deposition modeling) technique. Printing parameters were optimized to fabricate nerve-equivalent TPU constructs. The TPU constructs printed with different infill densities supported the adhesion, proliferation, and gene expression of neuronal cells. Subcutaneous implantation of the TPU constructs for three months in rats showed neovascularization with negligible local tissue inflammatory reactions and was classified as a non-irritant biomaterial as per ISO 10993-6. To performin vivoefficacy studies, nerve conduits equivalent to rat's sciatic nerve were fabricated and bridged in a 10 mm sciatic nerve transection model. After four months of implantation, the sensorimotor function and histological assessments revealed that the 3D printed TPU conduits promoted the regeneration in critical-sized peripheral nerve defects equivalent to autografts. This study proved that TPU-based 3D printed nerve guidance conduits can be created to replicate the complicated features of natural nerves that can promote the regeneration of peripheral nerve defects and also show the potential to be extended to several other tissues for regenerative medicine applications.


Asunto(s)
Regeneración Nerviosa , Poliuretanos , Impresión Tridimensional , Nervio Ciático , Andamios del Tejido , Animales , Poliuretanos/química , Poliuretanos/farmacología , Regeneración Nerviosa/efectos de los fármacos , Ratas , Nervio Ciático/fisiología , Nervio Ciático/lesiones , Nervio Ciático/efectos de los fármacos , Andamios del Tejido/química , Ratas Sprague-Dawley , Traumatismos de los Nervios Periféricos/terapia , Traumatismos de los Nervios Periféricos/patología , Masculino , Regeneración Tisular Dirigida/instrumentación , Regeneración Tisular Dirigida/métodos , Ingeniería de Tejidos/métodos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología
8.
Expert Opin Drug Deliv ; 21(6): 975-986, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38975698

RESUMEN

BACKGROUND: Glaucoma is one of the major irreversible blinding eye diseases in the world. Reducing intraocular pressure (IOP) is the primary treatment option, and taking eye drops daily is the common method. However, short drug duration and poor bioavailability of eye drops may lead to unsatisfied therapeutic effects and inadequate patient compliance. METHODS: A brimonidine-loaded silicone rubber insert (BRI@SR@PT) was prepared by loading brimonidine into a surface-modified silicone rubber ring, followed by polydopamine/thermoplastic polyurethane coatings. The physical properties, in vitro cytocompatibility and drug release of BRI@SR@PT were investigated. The BRI@SR@PT was administrated in the conjunctival sac of rabbit eyes, and its in vivo drug release, IOP-lowering efficacy and biosafety were assessed. RESULTS: The BRI@SR@PT presented great thermal stability and excellent elasticity. The BRI@SR@PT was able to release BRI sustainably for 28 days with little toxicity in vitro. Compared to BRI eye drops, the BRI@SR@PT effectively lowered IOP for 21 days based on the sustained BRI release with great biosafety when administrated in conjunctival sac of rabbit eyes in a noninvasive fashion. CONCLUSIONS: The conjunctival sac insert (BRI@SR@PT), as a promising drug-delivery platform, may provide a sustained IOP-lowering treatment for patients with ocular hypertension or glaucoma, without the need for invasive procedures.


Asunto(s)
Tartrato de Brimonidina , Preparaciones de Acción Retardada , Liberación de Fármacos , Glaucoma , Presión Intraocular , Poliuretanos , Conejos , Animales , Presión Intraocular/efectos de los fármacos , Glaucoma/tratamiento farmacológico , Tartrato de Brimonidina/administración & dosificación , Tartrato de Brimonidina/farmacología , Tartrato de Brimonidina/uso terapéutico , Poliuretanos/química , Poliuretanos/administración & dosificación , Sistemas de Liberación de Medicamentos , Polímeros/química , Elastómeros de Silicona/química , Conjuntiva , Soluciones Oftálmicas/administración & dosificación , Indoles/administración & dosificación , Indoles/farmacocinética , Masculino , Disponibilidad Biológica , Humanos , Antihipertensivos/administración & dosificación , Antihipertensivos/farmacología , Antihipertensivos/farmacocinética , Antihipertensivos/química
9.
Int J Mol Sci ; 25(13)2024 Jul 02.
Artículo en Inglés | MEDLINE | ID: mdl-39000407

RESUMEN

This work focused on the preparation and investigation of polyurethane (SO-PU)-containing sunflower oil glycerides. By transesterification of sunflower oil with glycerol, we synthesized a glyceride mixture with an equilibrium composition, which was used as a new diol component in polyurethanes in addition to poly(ε-caprolactone)diol (PCLD2000). The structure of the glyceride mixture was characterized by physicochemical methods, matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS), nuclear magnetic resonance spectroscopy (NMR), and size exclusion chromatography (SEC) measurements. The synthesis of polyurethanes was performed in two steps: first the prepolymer with the isocyanate end was synthesized, followed by crosslinking with an additional amount of diisocyanate. For the synthesis of the prepolymer, 4,4'-methylene diphenyl diisocyanate (MDI) or 1,6-hexamethylene diisocyanate (HDI) were used as isocyanate components, while the crosslinking was carried out using an additional amount of MDI or HDI. The obtained SO-PU flexible polymer films were characterized by attenuated total reflectance Fourier transform infrared spectroscopy (ATR-FTIR), differential scanning calorimetry (DSC), thermogravimetric analysis (TGA), and scanning electron microscopy (SEM). The so-obtained flexible SO-PU films were proved to be suitable for the preparation of potentially biocompatible and/or biodegradable scaffolds. In addition, the stress versus strain curves for the SO-PU polymers were interpreted in terms of a mechanical model, taking into account the yield and the strain hardening.


Asunto(s)
Polímeros , Poliuretanos , Aceite de Girasol , Poliuretanos/química , Polímeros/química , Aceite de Girasol/química , Materiales Biocompatibles/química , Isocianatos/química , Poliésteres/química , Espectroscopía de Resonancia Magnética , Espectroscopía Infrarroja por Transformada de Fourier
10.
J Biomed Mater Res B Appl Biomater ; 112(7): e35436, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38961592

RESUMEN

Submicron-textured surfaces have been a promising approach to mitigate biofilm development and control microbial infection. However, the use of the single surface texturing approach is still far from ideal for achieving complete control of microbial infections on implanted biomedical devices. The use of a surface topographic modification that might improve the utility of standard antibiotic therapy could alleviate the complications of biofilms on devices. In this study, we characterized the biofilms of Staphylococcus aureus and Pseudomonas aeruginosa on smooth and submicron-textured polyurethane surfaces after 1, 2, 3, and 7 days, and measured the efficacy of common antibiotics against these biofilms. Results show that the submicron-textured surfaces significantly reduced biofilm formation and growth, and that the efficacy of antibiotics against biofilms grown on textured surfaces was improved compared with smooth surfaces. The antibiotic efficacy appears to be related to the degree of biofilm development. At early time points in biofilm formation, antibiotic treatment reveals reasonably good antibiotic efficacy against biofilms on both smooth and textured surfaces, but as biofilms mature, the efficacy of antibiotics drops dramatically on smooth surfaces, with lesser decreases seen for the textured surfaces. The results demonstrate that surface texturing with submicron patterns is able to improve the use of standard antibiotic therapy to treat device-centered biofilms by slowing the development of the biofilm, thereby offering less resistance to antibiotic delivery to the bacteria within the biofilm community.


Asunto(s)
Antibacterianos , Biopelículas , Pseudomonas aeruginosa , Staphylococcus aureus , Propiedades de Superficie , Biopelículas/efectos de los fármacos , Biopelículas/crecimiento & desarrollo , Pseudomonas aeruginosa/efectos de los fármacos , Pseudomonas aeruginosa/crecimiento & desarrollo , Staphylococcus aureus/efectos de los fármacos , Staphylococcus aureus/crecimiento & desarrollo , Antibacterianos/farmacología , Antibacterianos/química , Poliuretanos/química , Poliuretanos/farmacología
11.
Int J Biol Macromol ; 275(Pt 2): 133562, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38955299

RESUMEN

Polymeric materials such as fabric and foam have high flammability which limits their application in the field of fire protection. To this end, an organic-inorganic polymer colloid constructed from carboxymethyl chitosan and ammonium polyphosphate was used to improve the flame retardancy of flax fabric (FF) and rigid polyurethane foam (RPUF) based on a "one for two" strategy. The modification processes of FF and RPUF relied on pad-dry-cure method and UV-curing technology, respectively, and the modified FF and RPUF were severally designated as CMC/APP-FF and RFR-RPUF. Flame retardancy studies showed that CMC/APP-FF and RFR-RPUF exhibited limiting oxygen index values as high as 39.4 % and 42.6 %, respectively, and both achieved self-extinguishing behavior when external ignition source was removed. Thermogravimetric analysis and cone calorimetry test confirmed that CMC/APP-FF and RFR-RPUF had good charring ability and demonstrated reduced peak heat release rate values of 90.1 % and 10.8 %, respectively, distinct from before they were modified. In addition, condensed phase analysis showed that after burning, CMC/APP-FF became an integration char structure, whereas RFR-RPUF turned into a sandwiched char structure. In summary, the "one for two" strategy reported in this work provides a new insight into the economical fabrication of flame-retardant polymeric materials.


Asunto(s)
Coloides , Retardadores de Llama , Lino , Poliuretanos , Poliuretanos/química , Lino/química , Coloides/química , Quitosano/química , Quitosano/análogos & derivados , Textiles , Polímeros/química , Polifosfatos/química
12.
J Hazard Mater ; 476: 135089, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-38959827

RESUMEN

The surge in face mask use due to COVID-19 has raised concerns about micro(nano)plastics (MNPs) from masks. Herein, focusing on fabric structure and polymer composition, we investigated MNP generation characteristics, mechanisms, and potential risks of surgical polypropylene (PP) and fashionable polyurethane (PU) masks during their wearing and photoaging based on stereomicroscope, µ-Fourier transform infrared spectroscopy (µ-FTIR), and scanning electron microscope (SEM) techniques. Compared with new PP and PU masks (66 ± 16 MPs/PP-mask, 163 ± 83 MPs/PU-mask), single- and multiple-used masks exhibited remarkably increased MP type and abundance (600-1867 MPs/PP-mask, 607-2167 MPs/PU-mask). Disinfection exacerbated endogenous MP generation in masks, with washing (416 MPs/PP-mask, 30,708 MPs/PU-mask) being the most prominent compared to autoclaving (219 MPs/PP-mask, 553 MPs/PU-mask) and alcohol spray (162 MPs/PP-mask, 18,333 MPs/PU-mask). Photoaging led to massive generation of MPs (8.8 × 104-3.7 × 105 MPs/PP-layer, 1.0 × 105 MPs/PU-layer) and NPs (5.2 × 109-3.6 × 1013 NPs/PP-layer, 3.5 × 1012 NPs/PU-layer) from masks, presenting highly fabric structure-dependent aging modes as "fragmentation" for fine fiber-structure PP mask and "erosion" for 3D mesh-structure PU mask. The MNPs derived from PP/PU mask caused significant deformities of Zebrafish (Danio rerio) larvae. These findings underscore the potential adverse effects of masks on humans and aquatic organisms, advocating to enhance proper use and rational disposal for masks.


Asunto(s)
COVID-19 , Máscaras , Polipropilenos , Poliuretanos , Textiles , Polipropilenos/química , COVID-19/prevención & control , Poliuretanos/química , Humanos , Textiles/análisis , Animales , SARS-CoV-2 , Polímeros/química , Microplásticos/toxicidad , Pez Cebra , Contaminación de Equipos/prevención & control
13.
J Hazard Mater ; 476: 135054, 2024 Sep 05.
Artículo en Inglés | MEDLINE | ID: mdl-38991647

RESUMEN

Microplastics (MPs) is an emerging pollutant potentially harmful to health. Medical practices using plastic devices, such as percutaneous coronary interventions (PCI), may result in MPs entering into the blood. The purpose of this study was to quantify the effect of PCI on microplastic levels in patients' blood. Laser direct infrared (LDIR) was used to detect MPs in the blood of 23 patients before and after PCI. MPs in the water in which devices used in PCI were washed were also examined. The concentration of MPs in the blood was significantly elevated (93.57 ± 35.95 vs. 4.96 ± 3.40 particles/10 mL of blood, P < 0.001) after PCI compared to before, and the increased MPs were polyamide (PA), polyethylene (PE), polyurethane (PU), and polyethylene terephthalate (PET), which was consistent with the types of MPs detected in the device washing water. The maximum diameter of MPs in blood before PCI was 50 µm, whereas after PCI it was 213 µm, and even 336 µm in device washing water. These findings indicated that PCI will cause MPs to enter the blood, and devices used during PCI were a major source, a range of medical practices that use plastic devices may be a new route for MPs to enter the human body.


Asunto(s)
Microplásticos , Intervención Coronaria Percutánea , Humanos , Microplásticos/análisis , Intervención Coronaria Percutánea/instrumentación , Masculino , Femenino , Anciano , Persona de Mediana Edad , Poliuretanos/química
14.
Environ Sci Pollut Res Int ; 31(36): 49342-49357, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39066944

RESUMEN

Phosphate is present in all kinds of industrial wastewater; how to remove it to meet the strict total phosphorus discharge standards is a challenge. This study used a one-step foaming technique to fill polyurethane foam (PUF) with ZnO, taking advantage of PUF's excellent features like its porous network, lightweight, hydrophilicity, and abundance of binding sites to create ZnO/PUF composites with high adsorption capacity and exceptional separation properties. The adsorption isotherms, kinetics, starting pH, and matrix impacts of ZnO/PUF composites on phosphate were examined in batch studies. The results showed that the composites had good adsorption performance for phosphate with a saturated adsorption capacity of 460.25 mg/g. The quasi-secondary kinetic and Langmuir models could better describe the adsorption process, which belonged to the chemical adsorption of monomolecular layers. The composites' ability to treat phosphates in complicated waters was shown by their ability to retain a high adsorption capacity in the pH range of 3-6. In column experiments, the composite also maintains a good affinity for phosphate during dynamic adsorption. Multiple characterizations indicate that the adsorption mechanism is a combined effect of ligand exchange and electrostatic interactions. Therefore, this study provides valuable insights for practical phosphorus-containing wastewater treatment.


Asunto(s)
Fosfatos , Poliuretanos , Óxido de Zinc , Adsorción , Fosfatos/química , Óxido de Zinc/química , Poliuretanos/química , Contaminantes Químicos del Agua/química , Aguas Residuales/química , Cinética , Concentración de Iones de Hidrógeno , Purificación del Agua/métodos
15.
Biomacromolecules ; 25(8): 5068-5080, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39041235

RESUMEN

Enzyme-responsive self-assembled nanostructures for drug delivery applications have gained a lot of attention, as enzymes exhibit dysregulation in many disease-associated microenvironments. Azoreductase enzyme levels are strongly elevated in many tumor tissues; hence, here, we exploited the altered enzyme activity of the azoreductase enzyme and designed a main-chain azobenzene-based amphiphilic polyurethane, which self-assembles into a vesicular nanostructure and is programmed to disassemble in response to a specific enzyme, azoreductase, with the help of the nicotinamide adenine dinucleotide phosphate (NADPH) coenzyme in the hypoxic environment of solid tumors. The vesicular nanostructure sequesters, stabilizes the hydrophobic anticancer drug, and releases the drug in a controlled fashion in response to enzyme-triggered degradation of azo-bonds and disruption of vesicular assembly. The biological evaluation revealed tumor extracellular matrix pH-induced surface charge modulation, selective activated cellular uptake to azoreductase overexpressed lung cancer cells (A549), and the release of the anticancer drug followed by cell death. In contrast, the benign nature of the drug-loaded vesicular nanostructure toward normal cells (H9c2) suggested excellent cell specificity. We envision that the main-chain azobenzene-based polyurethane discussed in this manuscript could be considered as a possible selective chemotherapeutic cargo against the azoreductase overexpressed cancer cells while shielding the normal cells from off-target toxicity.


Asunto(s)
Antineoplásicos , Compuestos Azo , Nitrorreductasas , Poliuretanos , Compuestos Azo/química , Compuestos Azo/farmacología , Humanos , Poliuretanos/química , Antineoplásicos/farmacología , Antineoplásicos/química , Células A549 , Nitrorreductasas/metabolismo , NADH NADPH Oxidorreductasas/metabolismo , Liberación de Fármacos , Nanoestructuras/química , Sistemas de Liberación de Medicamentos/métodos
16.
ACS Biomater Sci Eng ; 10(8): 5154-5167, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-39079153

RESUMEN

There remains a lack of small-caliber tissue-engineered blood vessels (TEBVs) with wide clinical use. Biotubes were developed by electrospinning and in-body tissue architecture (iBTA) technology to prepare small-caliber TEBVs with promising applications. Different ratios of hybrid fibers of poly(l-lactic-co-ε-caprolactone) (PLCL) and polyurethane (PU) were obtained by electrospinning, and the electrospun tubes were then implanted subcutaneously in the abdominal area of a rabbit (as an in vivo bioreactor). The biotubes were harvested after 4 weeks. They were then decellularized and cross-linked with heparin. PLCL/PU electrospun vascular tubes, decellularized biotubes (D-biotubes), and heparinized combined decellularized biotubes (H + D-biotubes) underwent carotid artery allograft transplantation in a rabbit model. Vascular ultrasound follow-up and histological observation revealed that the biotubes developed based on electrospinning and iBTA technology, after decellularization and heparinization cross-linking, showed a better patency rate, adequate mechanical properties, and remodeling ability in the rabbit model. IBTA technology caused a higher patency, and the heparinization cross-linking process gave the biotubes stronger mechanical properties.


Asunto(s)
Prótesis Vascular , Heparina , Poliésteres , Ingeniería de Tejidos , Animales , Conejos , Ingeniería de Tejidos/métodos , Heparina/química , Poliésteres/química , Aloinjertos , Poliuretanos/química , Andamios del Tejido/química , Arterias Carótidas
17.
ACS Appl Mater Interfaces ; 16(32): 42905-42916, 2024 Aug 14.
Artículo en Inglés | MEDLINE | ID: mdl-39023228

RESUMEN

The iontronic tactile sensing modality has garnered significant attention due to its exceptional sensitivity, immunity to noise, and versatility in materials. Recently, various formats of iontronic tactile sensors have been developed, including droplets, polymer films, paper, ionic gels, and fabrics. However, the stretchability of the current iontronic pressure sensing fabric is inadequate, hindered by the limited stretchiness of the ionic functional fabric. Incorporating a stretchable tactile sensing implement could enhance the wear comfortability by preventing relative movement and ensuring intimate contact between the sensor and the skin. The research focuses on the development of a stretchable iontronic pressure sensing (SIPS) fabric for monitoring diverse aspects of body health and movement in wearable applications. The tactile sensing structure is generated at the iontronic interface between highly stretchable ionic and conductive fabrics. In particular, the ionic fabric is prepared by coating a layer of polyurethane/ionic liquid gel onto a Spandex fabric. To showcase its remarkable sensitivity, stretchability, and ability to detect diverse body information, several application scenarios have been demonstrated including an elastic wristband for precise pulse wave detection, a flexible belt with multitactile sensing channels for respiration and motion tracking purposes, and a stretchable fabric cuff equipped with a high-resolution sensing array comprising 32 × 32 units for accurate gesture recognition.


Asunto(s)
Textiles , Tacto , Dispositivos Electrónicos Vestibles , Humanos , Tacto/fisiología , Poliuretanos/química , Líquidos Iónicos/química , Conductividad Eléctrica
18.
ACS Biomater Sci Eng ; 10(8): 5094-5107, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-38979636

RESUMEN

Intervertebral disc (IVD) herniation is a leading cause of disability and lower back pain, causing enormous socioeconomic burdens. The standard of care for disc herniation is nucleotomy, which alleviates pain but does not repair the annulus fibrosus (AF) defect nor recover the biomechanical function of the disc. Existing bioadhesives for AF repair are limited by insufficient adhesion and significant mechanical and geometrical mismatch with the AF tissue, resulting in the recurrence of protrusion or detachment of bioadhesives. Here, we report a composite hydrogel sealant constructed from a composite of a three-dimensional (3D)-printed thermoplastic polyurethane (TPU) mesh and tough hydrogel. We tailored the fiber angle and volume fraction of the TPU mesh design to match the angle-ply structure and mechanical properties of native AF. Also, we proposed and tested three types of geometrical design of the composite hydrogel sealant to match the defect shape and size. Our results show that the sealant could mimic native AF in terms of the elastic modulus, flexural modulus, and fracture toughness and form strong adhesion with the human AF tissue. The bovine IVD tests show the effectiveness of the composite hydrogel sealant for AF repair and biomechanics recovery and for preventing herniation with its heightened stiffness and superior adhesion. By harnessing the combined capabilities of 3D printing and bioadhesives, these composite hydrogel sealants demonstrate promising potential for diverse applications in tissue repair and regeneration.


Asunto(s)
Anillo Fibroso , Hidrogeles , Animales , Anillo Fibroso/efectos de los fármacos , Hidrogeles/química , Hidrogeles/farmacología , Bovinos , Humanos , Impresión Tridimensional , Poliuretanos/química , Poliuretanos/farmacología , Adhesivos Tisulares/farmacología , Adhesivos Tisulares/química
19.
ACS Biomater Sci Eng ; 10(8): 5237-5251, 2024 Aug 12.
Artículo en Inglés | MEDLINE | ID: mdl-38981095

RESUMEN

Popularized on social media, hand-moldable plastics are formed by consumers into tools, trinkets, and dental prosthetics. Despite the anticipated dermal and oral contact, manufacturers share little information with consumers about these materials, which are typically sold as microplastic-sized resin pellets. Inherent to their function, moldable plastics pose a risk of dermal and oral exposure to unknown leachable substances. We analyzed 12 moldable plastics advertised for modeling and dental applications and determined them to be polycaprolactone (PCL) or thermoplastic polyurethane (TPU). The bioactivities of the most popular brands advertised for modeling applications of each type of polymer were evaluated using a zebrafish embryo bioassay. While water-borne exposure to the TPU pellets did not affect the targeted developmental end points at any concentration tested, the PCL pellets were acutely toxic above 1 pellet/mL. The aqueous leachates of the PCL pellets demonstrated similar toxicity. Methanolic extracts from the PCL pellets were assayed for their bioactivity using the Attagene FACTORIAL platform. Of the 69 measured end points, the extracts activated nuclear receptors and transcription factors for xenobiotic metabolism (pregnane X receptor, PXR), lipid metabolism (peroxisome proliferator-activated receptor γ, PPARγ), and oxidative stress (nuclear factor erythroid 2-related factor 2, NRF2). By nontargeted high-resolution comprehensive two-dimensional gas chromatography (GC × GC-HRT), we tentatively identified several compounds in the methanolic extracts, including PCL oligomers, a phenolic antioxidant, and residues of suspected antihydrolysis and cross-linking additives. In a follow-up zebrafish embryo bioassay, because of its stated high purity, biomedical grade PCL was tested to mitigate any confounding effects due to chemical additives in the PCL pellets; it elicited comparable acute toxicity. From these orthogonal and complementary experiments, we suggest that the toxicity was due to oligomers and nanoplastics released from the PCL rather than chemical additives. These results challenge the perceived and assumed inertness of plastics and highlight their multiple sources of toxicity.


Asunto(s)
Poliésteres , Pez Cebra , Pez Cebra/embriología , Animales , Poliésteres/química , Poliésteres/toxicidad , Poliuretanos/química , Poliuretanos/toxicidad , Plásticos/química , Plásticos/toxicidad , Embrión no Mamífero/efectos de los fármacos , Embrión no Mamífero/metabolismo , Receptores Citoplasmáticos y Nucleares/metabolismo , Humanos
20.
Bioresour Technol ; 406: 131085, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38977038

RESUMEN

In this work, an effort has been made to enhance the efficacy of biological process for the effective degradation of 2, 4-dichlorophenol (2, 4-DCP) from wastewater. The polyurethane foam was modified with Fe3O4 nanoparticles and combined with polyvinyl alcohol, sodium alginate, and bacterial consortium for biodegradation of 2, 4-DCP in a packed bed biofilm reactor. The maximum removal efficiency of 2, 4-DCP chemical oxygen demand, and total organic carbon were found to be 92.51 ± 0.83 %, 86.85 ± 1.32, and 91.78 ± 1.24 %, respectively, in 4 days and 100 mg L-1 of 2, 4-DCP concentration at an influent loading rate of 2 mg L-1h-1 and hydraulic retention time of 50 h. Packed bed biofilm reactor was effective for up to four cycles to remove 2, 4-DCP. Growth inhibition kinetics were evaluated using the Edward model, yielding maximum growth rate of 0.45 day-1, inhibition constant of 110.6 mg L-1, and saturation constant of 62.3 mg L-1.


Asunto(s)
Biodegradación Ambiental , Biopelículas , Reactores Biológicos , Clorofenoles , Poliuretanos , Poliuretanos/química , Biopelículas/efectos de los fármacos , Cinética , Contaminantes Químicos del Agua , Animales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...