Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.384
Filtrar
1.
Sci Rep ; 14(1): 18640, 2024 08 11.
Artículo en Inglés | MEDLINE | ID: mdl-39128909

RESUMEN

Rehabilitation of pulpotomized primary molars with an appropriate restoration is essential for recovering function and safeguarding the durability of the treatment. This study aimed to assess and compare the surface roughness of stainless steel (ST) crowns, zirconia (ZR) crowns, fiberglass (FG) crowns, and lithium disilicate (LD) endo-crowns as a restoration for pulpotomized primary molars also, evaluating the surface roughness of their antagonists. Sixty pulpotomized primary mandibular first molars were used for qualitative surface roughness evaluation and divided into four groups (n = 15/group) according to the crown type (group-ST, group-ZR, group-FG, group-LD). While the other sixty sound, unprepared primary maxillary first molars were used for evaluation of their surface roughness against the tested crowns. Specimens' preparation and cementation were carried out according to each crown type and manufacturer's instructions. The surface roughness was done using a two-body wear test. The data were statistically analyzed. All tested crowns showed an increased change in surface roughness, except group-ZR, which had the least change in surface roughness after mechanical wear with no statistically significant difference(P = 0.681). All crown types significantly increased the surface roughness of their antagonists after mechanical wear, except group-ST which showed insignificant affection (p ≥ 0.05). Zirconia crowns and lithium disilicate endo-crowns had the least change in surface roughness compared to other groups while SSCs showed the least tooth loss in the antagonist enamel.


Asunto(s)
Coronas , Porcelana Dental , Diente Molar , Propiedades de Superficie , Diente Primario , Circonio , Porcelana Dental/química , Humanos , Circonio/química , Acero Inoxidable/química , Ensayo de Materiales
2.
Clin Oral Investig ; 28(9): 473, 2024 Aug 07.
Artículo en Inglés | MEDLINE | ID: mdl-39110133

RESUMEN

PURPOSE: To investigate the effects of different surface treatments and thicknesses on the color, transparency, and surface roughness of ultra-transparent zirconia. METHODS: A total of 120 Katana ultra-translucent multi-layered zirconia specimens were divided into 12 groups according to the thickness (0.3, 0.5, and 0.7 mm) and surface treatment (control, airborne particle abrasion [APA], lithium disilicate coating, and glaze on). Color difference (ΔE00) and relative translucency parameter (RTP00) were calculated using a digital spectrophotometer. The surface roughness (Ra, Rq, Sa, and Sq) was measured using a non-contact profile scanner. The surface morphologies and microstructures of the samples were observed using a tungsten filament scanning electron microscope. Statistical analyses were performed by one-way and two-way analysis of variance (ANOVA) followed by post hoc multiple comparisons and Pearson's correlation (α = 0.05). RESULTS: The results showed that the surface treatment, ceramic thickness, and their interactions had significant effects on ΔE00 and RTP00 (p < 0.001). The surface treatment significantly altered the micromorphology and increased the surface roughness of the ceramic samples. APA exhibited the lowest transparency, largest color difference, and highest surface roughness. Zirconia with 0.3 mm and 0.7 mm thicknesses showed strong negative correlations between Sa and RTP00. CONCLUSIONS: The three internal surface treatments significantly altered the surface roughness, color difference, and transparency of ultra-transparent zirconia. As the thickness increased, the influence of the inner surface treatment on the color difference and transparency of zirconia decreased. CLINICAL IMPLICATIONS: For new zirconia internal surface treatment technologies, in addition to considering the enhancement effect on the bonding properties, the potential effects on the color and translucency of high-transparency zirconia should also be considered. Appropriately increasing the thickness of zirconia restorations helps minimize the effect of surface treatment on the optical properties.


Asunto(s)
Color , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Espectrofotometría , Propiedades de Superficie , Circonio , Circonio/química , Porcelana Dental/química , Materiales Dentales/química , Recubrimiento Dental Adhesivo/métodos
3.
BMC Oral Health ; 24(1): 913, 2024 Aug 08.
Artículo en Inglés | MEDLINE | ID: mdl-39118080

RESUMEN

OBJECTIVES: This study aimed to evaluate the feasibility of monolithic zirconia laminate veneers (MZLV) compared to lithium disilicate laminate veneers (LDLV). MATERIALS AND METHODS: Sixty resin replicas, each prepared with depths of 0.5 mm, 0.7 mm, and 1 mm, were produced using a 3D printer from acrylic teeth. Laminate veneers of these thicknesses were milled from pre-sintered monolithic zirconia (3rd generation) and lithium disilicate blocks. The intaglio surface of MZLV was treated with air abrasion using 110 µm diameter silica-modified aluminium oxide particles and ceramic primer, while LDLV was etched with etchant gel and treated with the ceramic primer before cementation with resin cement. Vertical marginal discrepancy (VMD) was assessed using a stereomicroscope, and a load-to-failure test was conducted using a universal testing machine. Failure modes were evaluated macroscopically on fractured surfaces. Data were analysed statistically using Two-way ANOVA and Bonferroni correction (α = 0.05). RESULTS: LDLV samples exhibited significantly larger VMD compared to MZLV samples across all thicknesses, especially in cervical, palatal, and mean data. Within the LDLV group, load-to-fracture values for 0.7 mm and 1.0 mm thicknesses were similar, whereas for 0.5 mm thickness, it was significantly lower. In the MZLV group, load-to-fracture values were lower for 0.7 mm and 1.0 mm thicknesses compared to LDLV, but higher for 0.5 mm thickness. CONCLUSIONS: Material choice and restoration thickness significantly influence laminate veneer restorations' success. MZLV generally exhibits superior vertical marginal fit compared to LDLV, with varying load-to-failure values across different thicknesses. Clinical management of debonding in MZLV is simpler compared to restoration fracture in LDLV. CLINICAL RELEVANCE: Considering clinical factors, MZLV may be a preferable option to LDLV for this restoration with the thickness of 0.5 mm.


Asunto(s)
Adaptación Marginal Dental , Porcelana Dental , Coronas con Frente Estético , Circonio , Porcelana Dental/química , Circonio/química , Humanos , Ensayo de Materiales , Análisis del Estrés Dental , Fracaso de la Restauración Dental , Propiedades de Superficie , Materiales Dentales/química , Diseño de Prótesis Dental
4.
BMC Oral Health ; 24(1): 765, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970080

RESUMEN

OBJECTIVE: To determine the effects of conventional cigarette smoking (CS) and recent heated tobacco products (HTPs) on the surface roughness and color stability of different indirect restorative materials. MATERIALS AND METHODS: One hundred disc-shaped samples were constructed of three different restorative CAD/CAM materials: lithium disilicate glass-ceramic (IPS e.max CAD; Ivoclar Vivadent, Liechtenstein), zirconia (BruxZir® Zirconia, Glidewell, USA) and polyetheretherketone (BioHPP® bredent GmbH, Germany). Of the IPS e.max CAD and the Bruxzir samples, 20 samples were glazed, and 20 samples were polished, while the BioHPP samples were all polished according to the manufacturer's instructions. Fifty samples were subjected to conventional cigarette smoking (LM, Philip Morris International Inc., Egypt) (Groups: IPS e.max CAD_Glazed exposed to CS (LD_G_Cig), IPS e.max CAD_Polished exposed to CS (LD_P_Cig), Bruxzir_Glazed exposed to CS (Zr_G_Cig), Bruxzir _Polished exposed to CS (Zr_P_Cig) and BioHPP exposed to CS (PEEK_Cig) and fifty samples were exposed to heated tobacco product smoking (Heets, Russet selection, Philip Morris International Inc., Italy) (Groups: IPS e.max CAD_Glazed exposed to HTP (LD_G_HTP), IPS e.max CAD_Polished exposed to HTP (LD_P_HTP), Bruxzir_Glazed exposed to HTP (Zr_G_HTP), Bruxzir CAD_Polished exposed to HTP (Zr_P_HTP) and BioHPP exposed to HTP (PEEK_HTP).. Six hundred cigarettes/heets representing 30 days of medium smoking behavior (20 cigarettes/day) were used. Before and after exposure to smoke, the surface roughness of all the samples was measured using JITAI8101 surface roughness tester (Beijing Jitai Tech Detection Device Co., Ltd, China, and the color parameters were assessed using VITA Easyshade Advance 4.01 (VITA shade, VITA made, VITA). The data were analyzed using One-way ANOVA, paired sample t-test and independent sample t-test. The significance level was set at α < 0.05. The surface topography was evaluated by scanning electron microscopy (SEM) and analyzed using energy-dispersive X-ray (EDX) spectroscopy to determine changes in the surface chemical composition. RESULTS: Both types of smoking caused significant increases in the surface roughness of all the samples. There was a significant difference in color change between CS and HTP for all materials with different surface finish (P < 0.01) and zirconia had the greatest effect on color change (P < 0.001). In contrast, polyetheretherketone (PEEK) "BioHPP" had the least effect (P < 0.001). CONCLUSION: Exposure to different types of smoking induce changes in the surface topography and color of different esthetic restorative materials. Compared with HTP, conventional cigarette smoke has a greater effect on the surface roughness and color stability of esthetic restorative materials. The glazed surfaces showed less change in surface topography than did the polished surfaces. Zirconia showed better color stability when compared to polyetheretherketone (PEEK).


Asunto(s)
Cerámica , Fumar Cigarrillos , Diseño Asistido por Computadora , Materiales Dentales , Porcelana Dental , Cetonas , Polietilenglicoles , Polímeros , Propiedades de Superficie , Productos de Tabaco , Circonio , Polietilenglicoles/química , Circonio/química , Productos de Tabaco/efectos adversos , Cerámica/química , Cetonas/química , Porcelana Dental/química , Fumar Cigarrillos/efectos adversos , Materiales Dentales/química , Benzofenonas , Ensayo de Materiales , Calor , Humanos , Color , Restauración Dental Permanente
5.
Clin Exp Dent Res ; 10(4): e918, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38970231

RESUMEN

AIMS AND OBJECTIVES: To evaluate the effect of coffee thermocycling on color stability and translucency of CAD-CAM polychromatic high translucent zirconia compared with lithium disilicate glass ceramic. METHODS: Sixteen rectangular plates (14 × 16 × 1.0 mm) of two ceramic materials (IPS E.max CAD (IEC), IPS E.max ZirCAD Prime [IZP]) were prepared. Each specimen was measured for color coordinates using a spectrophotometer following 30,000 cycles of coffee thermocycling. CIELAB formula was used to determine color and translucency differences (ΔE and ΔTP). The means of ΔE and ΔTP were compared using independent samples t-test and were evaluated using their respective 50%:50% perceptibility and acceptability thresholds (PT and AT). One-way analysis of variance was performed to evaluate the translucency parameter (TP) and surface roughness (Ra) of each material. RESULTS: Mean ΔE values of IEC (4.69) and IZP (4.64) were higher than the AT (ΔE ≤ 2.7) with no significant difference found between the two groups (p = 0.202). Considering the TP, only IEC showed a statistically significant increase in TP value (p < 0.001). However, the mean ΔTP of IEC (3.25) remained within the range of acceptability (1.3 < ΔTP ≤ 4.4). CONCLUSIONS: Within the limitations of this current study, the color stability of all materials was clinically affected by coffee thermocycling. In terms of translucency, only lithium disilicate glass ceramic was influenced by coffee thermocycling. High translucent zirconia had superior translucency stability compared to lithium disilicate glass ceramic.


Asunto(s)
Cerámica , Café , Color , Diseño Asistido por Computadora , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie , Circonio , Cerámica/química , Porcelana Dental/química , Circonio/química , Café/química , Humanos , Espectrofotometría , Materiales Dentales/química
6.
Clin Exp Dent Res ; 10(4): e916, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38970227

RESUMEN

OBJECTIVES: This study assessed the effects of 15% and 20% carbamide peroxide (CP) on color, surface roughness, and hardness of computer-aided design/computer-aided manufacturing (CAD/CAM) dental ceramics. MATERIALS AND METHODS: This in vitro study was conducted on 120 Vita Mark II, Celtra Duo, and Suprinity CAD/CAM ceramic specimens. The ceramic specimens in each group (n = 40) were randomly assigned to two subgroups (n = 20) for polishing and glazing, and their baseline color, surface roughness (Ra), and hardness were assessed. In each subgroup, half of the specimens were exposed to 15% CP, while the other half were exposed to 20% CP. Their color change (ΔE), surface roughness, and hardness were then measured again. Surface roughness, hardness, and color were analyzed sequentially by profilometer, Vickers hardness tester, and spectrophotometer, respectively. Data were analyzed by repeated measures ANOVA, one-way ANOVA, and post hoc Bonferroni test (α = 0.05). RESULTS: The surface roughness of all groups significantly increased after bleaching treatment (p < 0.05). Surface hardness of all groups decreased after bleaching treatment, but this reduction was only significant in Vita Mark II subgroups (glazed, polished, 15%, and 20% CP). The ΔE was not clinically and visually perceivable in any group. CONCLUSION: The present results revealed that concentration of CP and type of surface treatment affected the surface properties of CAD/CAM ceramics. Type of surface treatment only affected the surface hardness of Vita Mark II ceramics (p < 0.05). Concentration of CP had a significant effect only on polished Vita Mark II.


Asunto(s)
Peróxido de Carbamida , Cerámica , Color , Diseño Asistido por Computadora , Dureza , Ensayo de Materiales , Peróxidos , Propiedades de Superficie , Peróxido de Carbamida/química , Propiedades de Superficie/efectos de los fármacos , Dureza/efectos de los fármacos , Cerámica/química , Peróxidos/química , Porcelana Dental/química , Urea/química , Urea/análogos & derivados , Urea/farmacología , Blanqueadores Dentales/química , Humanos , Técnicas In Vitro , Materiales Dentales/química , Espectrofotometría
7.
Shanghai Kou Qiang Yi Xue ; 33(2): 200-204, 2024 Apr.
Artículo en Chino | MEDLINE | ID: mdl-39005100

RESUMEN

PURPOSE: To analyse the types of chairside CAD/CAM all-ceramic restorations and the color range of all-ceramic materials used so as to provide reference for the application of clinical chairside all-ceramic restoration and the color selection of all-ceramic materials. METHODS: IPS e.max CAD prostheses and related data were collected from January 2021 to December 2021 from the Department of Prosthodontics, Shanghai Ninth People's Hospital, Shanghai Jiao Tong University School of Medicine. The number and type of restorations and the color of materials were investigated and analyzed by descriptive statistics. RESULTS: A total of 1 374 restorations were included, of which 624 were crown restorations, accounting for 45.41% of the total restorations. 516 cases were veneer, accounting for 37.55%; 219 were inlays, accounting for 15.94%; fixed bridges were all adhesive bridges, with the least number with only 15 cases, accounting for 1.09%. In terms of the selection of restoration materials, the use rate of low-transparent(LT) ceramic blocks was significantly higher than that of other transparent ceramic blocks. A was the most frequently used ceramic color. The most frequently used porcelain blocks for veneers were LTA2 and LTA1; for inlay were LTA3; for crowns were LTA2 and LTA3. The blocks used in the fixed bridges were all LT, and A3 color was the majority. CONCLUSIONS: Chairside CAD/CAM all-ceramic prostheses made of IPS e.max CAD materials have been widely used in clinical practice. The types of prostheses include veneer, inset, crown and fixed bridge. The most commonly used IPS e.max CAD blocks are LTA2, LTA3 and LTA1. These findings have certain guiding significance for the clinical restoration decision and the reserve of porcelain blocks in primary hospitals.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Cerámica/química , Diseño de Prótesis Dental/métodos , Porcelana Dental/química , Color , Humanos , Coronas con Frente Estético , Incrustaciones/métodos , Restauración Dental Permanente/métodos
8.
BMC Oral Health ; 24(1): 845, 2024 Jul 26.
Artículo en Inglés | MEDLINE | ID: mdl-39060942

RESUMEN

BACKGROUND: The fit of a metal-ceramic restoration is essential to its long-term durability. Regarding marginal and internal fit, there is not enough information about the technologies used in the production of metal-ceramic restorations. The aim of this in vitro study is to compare, both before and after porcelain firing, the marginal, axial, axio-occlusal, and occlusal fit of metal-ceramic restorations manufactured using casting, additive or subtractive computer-aided design, and computer-aided manufacturing techniques (CAD/CAM). METHODS: CAD/CAM were used to create 50 prepared maxillary first molar-shaped Co-Cr die models, which were randomly divided into 5 groups (n = 10). Cobalt-chrome copings were produced by casting (C), hard metal milling (HM), soft metal milling (SM), selective laser melting (SLM), and selective laser sintering (SLS) techniques. Before and after porcelain firing, discrepancies of the copings were measured using the silicone replica technique. The data obtained by measurements with a stereomicroscope at x80 magnification were analyzed statistically in the SPSS program. The ROBUST three-way analysis of variance (ANOVA) method was used to compare the discrepancy values. RESULTS: There were statistically significant differences among fabrication methods (P < .001). The HM method showed the highest discrepancy (90.1 µm), and the C (63 µm) method showed the lowest discrepancy in terms of the die model- crown fit. The C, SLS, and SM methods (63 µm; 61.6 µm; 67.7 µm) were statistically similar (P > .001). The highest discrepancy was observed on the occlusal area (87.1 µm), and the lowest discrepancy was observed on the axial area (47.7 µm) of the coping. Porcelain firing had a decrease in the discrepancy values (P = .001). CONCLUSION: All CAD/CAM techniques are appropriate for clinical use; selective laser sintering and soft milling can be the more recommended methods for the compatibility of metal-porcelain restorations, as they have lower discrepancy values than the SLM and HM methods.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Porcelana Dental , Diseño de Prótesis Dental , Aleaciones de Cerámica y Metal , Aleaciones de Cerámica y Metal/química , Porcelana Dental/química , Humanos , Técnica de Colado Dental , Adaptación Marginal Dental , Técnicas In Vitro , Aleaciones de Cromo/química
9.
Oper Dent ; 49(4): 403-411, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38978316

RESUMEN

BACKGROUND: Marginal adaptation and retention of endocrowns are crucial for the success and survival of endocrowns. This study aimed to investigate the effect of different materials and intracoronal depth on the retention and marginal adaptation of CAD/CAM fabricated all-ceramic endocrowns. METHODS: Thirty-six mandibular premolar teeth with an average surface area of 64.49 mm2 were prepared to receive CAM/CAM fabricated endocrowns. Samples were divided randomly and equally into groups of lithium disilicate with 2 mm intracoronal depth (LD2), lithium disilicate with 4 mm intracoronal depth (LD4), polymer infiltrated ceramic network with 2 mm intracoronal depth (PICN2) and polymer infiltrated ceramic network with 4 mm intracoronal depth (PICN4). All endocrowns were cemented using ParaCore resin cement with 14N pressure and cured for 20 seconds. Fifty measurements of absolute marginal discrepancy (AMD) were done using a stereomicroscope after cementation. After 24 hours, all samples were subjected to thermocycling before the retention test. This involved using a universal testing machine with a crosshead speed of 0.5 mm/min and applying a load of 500N. The maximum force to detach the crown was recorded in newtons and the mode of failure was identified. RESULTS: Two-way ANOVA revealed that the AMD for PICN was statistically significantly better than lithium disilicate (p=0.01). No statistically significant difference was detected in the AMD between the two intracoronal depths (p=0.72). PICN and endocrowns with 4 mm intracoronal depth had statistically significant better retention (p<0.05). 72.22% of the sample suffered from cohesive failures and 10 LD endocrowns suffered adhesive failures. CONCLUSIONS: Within the limitations of this study, we found that different materials and intracoronal depths can indeed influence the retention of CAD/CAM fabricated endocrowns. Based on the controlled setting findings, PICN was found to have better retention and better marginal adaptation than similar lithium disilicate premolar endocrowns.


Asunto(s)
Diseño Asistido por Computadora , Coronas , Adaptación Marginal Dental , Humanos , Técnicas In Vitro , Porcelana Dental/uso terapéutico , Porcelana Dental/química , Diente Premolar , Diseño de Prótesis Dental/métodos , Cerámica/uso terapéutico , Retención de Prótesis Dentales/métodos , Cementos de Resina , Análisis del Estrés Dental
10.
J Dent ; 148: 105257, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-39043330

RESUMEN

OBJECTIVE: Evaluate the impact of a "fast" crystallization and simultaneous-glazing on the physicochemical properties of lithium-disilicate CAD/CAM-ceramic. METHODS: Lithium-disilicate bars and crowns (IPS e.max CAD, Ivoclar-Vivadent) were divided into four groups (n = 30): WG/F (WG=with glaze/F=fast crystallization), NG/F (NG=no glaze), WG/C (C=conventional crystallization), and NG/C. A liquid/powder glaze system was used (IPS Ivocolor®, Ivoclar-Vivadent). Specimens were crystallized (Programat P310, Ivoclar-Vivadent) using the P161 program for C (approx. 20-25 min), and P165 for F (approx. 14-16 min). Bars (n = 30) underwent three-point bending tests (flexural strength-FS in MPa and modulus of elasticity-E in GPa) using a universal testing machine. Crowns were analyzed via scanning electron microscopy (SEM) after selective etching, and to Raman, FTIR-ATR, and X-ray diffraction (XRD) spectroscopies to assess chemical composition. RESULTS: For FS, both factors/interaction were statistically significant. C (427.48±42.41 MPa) showed significantly higher values than F (409.82±38.82 MPa). WG (398.32±29.80 MPa) exhibited significantly lower FS than NG (438.21±41.77 MPa). For E data, both factors/interaction were significant. NG (90.28±14.71 GPa) displayed higher E than WG (83.07±5.69 GPa), while C (90.08±12.98 GPa) exhibited higher E than F (83.46±9.40 GPa). NG/C showed the best results for both variables. F groups showed (SEM) porous surfaces and crack-like marks on crystals. FTIR, Raman and XRD spectra confirmed the typical composition of a lithium-disilicate glass ceramic, and some attenuated signals and structural variations (XRD) in WG. CONCLUSIONS: "Fast" crystallization and simultaneous-glazing produced weaker/less-rigid structures with irregular crystals and glassy phases. Simultaneous glazing may have hindered proper thermal distribution during crystallization. SIGNIFICANCE: "Fast" crystallization and simultaneous glazing with non-recommended systems, can adversely affect the final properties of lithium disilicate restorations.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Coronas , Cristalización , Porcelana Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Porcelana Dental/química , Cerámica/química , Espectroscopía Infrarroja por Transformada de Fourier , Análisis del Estrés Dental , Resistencia Flexional , Humanos , Módulo de Elasticidad , Difracción de Rayos X , Espectrometría Raman
11.
J Indian Prosthodont Soc ; 24(3): 292-299, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38946514

RESUMEN

AIM: Studies have not been done to evaluate the peri-implant stress exerted by materials(like PEEK and resin matrix ceramics) in different osseointegration conditions. To investigate the effect of different occlusal materials on peri-implant stress distribution with different osseointegration condition using finite element analysis. SETTINGS AND DESIGN: Eighteen different 3D FEA models of implant fixed with abutment were created involving 6 different occlusal materials (Heat cured temporary acrylic resin (PMMA), Bis-GMA, PEEK, Lithium disilicate, Resin matrix ceramics and translucent Zirconia) and different osseointegrated conditions (50%, 75%, 100%). MATERIALS AND METHODS: Models were subjected to loading vertically and obliquely followed by evaluation of stress distribution. STATISTICAL ANALYSIS USED: The results of the simulation obtained were analysed in terms of Von mises, maximum principal and minimal principal stresses using descriptive stastistics. RESULTS: PMMA (40.14 MPa on vertical loading and 66 MPa on oblique loading) resulted in the highest stresses and lithium disilicate (24 MPa on vertical loading and 52.40 MPa on oblique loading) resulted in least stresses among all the crown materials. Upon oblique loading, von Mises stress increases except for translucent zirconia and lithium disilicate (52.444 MPa on 50%, 47.733 MPa on 75%, and 43.973 MPa on 100% osseointegration). Minimal principal stress values decreased with increase in osseointegration upon oblique loading for PMMA, BisGMA, and PEEK. CONCLUSION: Translucent zirconia and lithium disilicate offer a better stress transmission. Minimal principal stress values of PEEK and BisGMA decreased with increasing osseointegration.


Asunto(s)
Materiales Dentales , Análisis de Elementos Finitos , Oseointegración , Oseointegración/efectos de los fármacos , Materiales Dentales/química , Implantes Dentales , Circonio/química , Humanos , Porcelana Dental/química , Cerámica/química , Ensayo de Materiales , Estrés Mecánico , Análisis del Estrés Dental/métodos , Polimetil Metacrilato/química , Polímeros/química
12.
Am J Dent ; 37(3): 141-146, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899994

RESUMEN

PURPOSE: To evaluate the effect of air abrasion and polishing procedures on roughness and color stability of ceramic and composite materials after artificial accelerated aging. METHODS: In this study, six restorative materials were tested: feldspathic ceramic (CEREC Blocks), glass ceramic (IPS e.max CAD), resin-based hybrid ceramic (Cerasmart), microhybrid composite (Charisma Classic), nanohybrid composite (Charisma Diamond) and nanoceramic composite (CeramXOne). Forty square-shaped composite specimens were fabricated from each composite and CAD-CAM ceramic material. Initial surface roughness measurements were performed using a profilometer and color measurements of each specimen with a spectrophotometer. Ten control specimens for each group did not receive air abrasion. The other specimens were treated by an air abrasion device and then were randomly divided into three subgroups of 10 specimens (n= 10). After air abrasion, 10 specimens of each group did not receive polishing (Air abrasion group) and others were repolished with Sof-Lex kit (Sof-Lex group) or a rubber kit (Rubber group). Surface roughness and color measurements were repeated before and after 300 hours of artificial accelerated aging (AAA). The univariate test and then three-way ANOVA and two-way ANOVA were performed for comparison of groups (α= 0.05). RESULTS: The univariate statistical analysis revealed that the restorative materials were differently affected after air abrasion, polishing methods and AAA (P< 0.001). Three-way ANOVA showed that the surface roughness of the restorative materials increased after air abrasion and AAA (P< 0.001). Two-way ANOVA showed statistically significant differences between color changes of ceramic (CEREC and IPS e.max CAD) and composite based restorative materials (P< 0.001). CLINICAL SIGNIFICANCE: Clinicians should be aware that air abrasion at a specified power and time significantly changes the surface roughness of the materials except for CEREC. Additionally, polishing procedures (Sof-Lex, Rubber) did not significantly reduce the surface roughness of the ceramic groups. After air abrasion, depending on the material type used clinically, restorations should be repolished to reduce roughness and ensure color stability.


Asunto(s)
Cerámica , Color , Resinas Compuestas , Pulido Dental , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie , Pulido Dental/métodos , Resinas Compuestas/química , Cerámica/química , Porcelana Dental/química , Materiales Dentales/química , Abrasión Dental por Aire , Factores de Tiempo , Diseño Asistido por Computadora , Silicatos de Aluminio/química , Espectrofotometría , Humanos , Compuestos de Potasio/química
13.
Am J Dent ; 37(3): 164-168, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899998

RESUMEN

PURPOSE: To investigate the effect of different abutments and crowns on the color of implant-supported restorations. METHODS: Zirconia and lithium disilicate (e.max) disks with A2 shade were fabricated to represent two crowns. The implant abutments were untreated titanium, opaqued titanium, anodized titanium, A2 shade zirconia and white zirconia. 4.0 mm-thickness zirconia and e.max specimens were used as references respectively. The crowns were placed on tested abutments with a drop of clear glycerin between them and the color was measured using a digital spectrophotometer. CIELab values were recorded to evaluate color differences (ΔE) between tested specimens and the references. RESULTS: Titanium abutments presented higher color differences than zirconia. The ΔE values with untreated titanium were higher than those with opaqued titanium. No differences were found between untreated titanium and anodized titanium for zirconia crowns. The ΔE values of zirconia crowns showed no significant differences between shade A2 zirconia and white zirconia abutments; e.max crowns showed a significant difference. The zirconia crown ΔE values were lower than those of e.max for all titanium and A2 zirconia abutments. Lithium disilicate crowns and zirconia abutments may be more suitable for implant-supported restorations. Opaqued titanium abutment may improve color in esthetic regions when a ceramic abutment cannot be used. CLINICAL SIGNIFICANCE: Lithium disilicate crowns and zirconia abutments may be an effective method to achieve excellent color matching in esthetic regions with implant-supported restorations.


Asunto(s)
Color , Coronas , Pilares Dentales , Porcelana Dental , Prótesis Dental de Soporte Implantado , Titanio , Circonio , Circonio/química , Titanio/química , Porcelana Dental/química , Materiales Dentales/química , Espectrofotometría , Diseño de Implante Dental-Pilar , Ensayo de Materiales , Humanos , Coloración de Prótesis
14.
BMC Oral Health ; 24(1): 696, 2024 Jun 15.
Artículo en Inglés | MEDLINE | ID: mdl-38879492

RESUMEN

BACKGROUND: An optimum restoration for reconstructing endodontically treated teeth should provide excellent marginal adaptation, high fracture resistance as well as maximum tooth structure conservation. The purpose of this study was to evaluate the marginal adaptation and fatigue resistance of different coronal restorations in endodontically treated premolars. METHODS: Thirty sound maxillary first premolars were endodontically treated and received MOD cavities. Teeth were randomly allocated into three groups (n = 10) according to the type of coronal restoration: Group R: polyethylene fibers (ribbond), fibers-reinforced composite (everX posterior) and final layer of nano-hybrid composite. Group O: indirect lithium disilicate overlay and Group C: fiber-post, resin composite restoration, and lithium disilicate crown. Marginal gap assessment was performed before and after thermocycling (5000 cycles) using stereomicroscope. Samples were subjected to stepwise-stress loading starting at 200 N, and increased by 100 N in each step until failure occurred. Statistical analysis was done by One-way ANOVA followed Tukey`s Post Hoc test for multiple comparison. Paired t test was used to compare the marginal adaptation before and after thermocycling. Survival probability was evaluated by Life table survival analysis. Failure mode analysis was performed with Chi-square test. RESULTS: Marginal gap was significantly the lowest in group R (37.49 ± 5.05) and (42.68 ± 2.38), while being the highest in group C (59.78 ± 5.67) and (71.52 ± 5.18) in before and after thermocycling respectively (P < 0.0001). Fatigue resistance was the highest for group O (1310.8 ± 196.7), and the lowest for group R (905.4 ± 170.51) with a significant difference between groups (P < 0.0001). Crown group had the highest percentage (80%) of catastrophic failure, while, overlay group exhibited the lowest (20%). CONCLUSIONS: Direct restoration without cuspal coverage using ribbon fibers with short FRC provided better marginal adaptation than indirect overlays and crowns, but fatigue resistance wasn't significantly improved. Adhesive ceramic overlays showed the best fatigue performance and the least catastrophic failure rate compared to both direct fiber-reinforced composite and indirect ceramic full coverage restorations. CLINICAL SIGNIFICANCE: Indirect adhesive overlays are a suitable, more conservative restorative option for endodontically treated teeth than full coverage restorations, especially when tooth structure is severely compromised.


Asunto(s)
Diente Premolar , Resinas Compuestas , Coronas , Adaptación Marginal Dental , Técnica de Perno Muñón , Diente no Vital , Humanos , Resinas Compuestas/química , Técnicas In Vitro , Restauración Dental Permanente/métodos , Porcelana Dental/química , Análisis del Estrés Dental , Polietilenos/química , Fracaso de la Restauración Dental , Ensayo de Materiales , Materiales Dentales/química
15.
BMC Oral Health ; 24(1): 660, 2024 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-38840111

RESUMEN

BACKGROUND: Effects of ceramic translucency, layer thickness, and substrate colour on the shade of lithium disilicate glass-ceramic restorations proved to be significant in several studies, however, quantitative, numerical results on the relationship between the colour difference and these parameters are still lacking. The purpose of this in vitro study was to quantitatively determine how the colour reproduction ability of a lithium disilicate glass-ceramic is affected by its translucency, layer thickness, and substrate colour. METHODS: Ceramic samples were prepared from A2 shade IPS e.max CAD blocks with high and low translucencies (HT and LT) in a thickness range of 0.5-2.5 mm (+/- 0.05 mm). Layered samples were acquired utilizing composite substrates in 9 shades; transparent try-in paste was used. The spectral reflectance of the specimens was assessed under D65 standard illumination with a Konica Minolta CM-3720d spectrophotometer. The CIEDE2000 colour difference (ΔE00) between two samples was analysed using perceptibility and acceptability thresholds set at 50:50%. Statistical analysis involved linear regression analysis and the Kruskal-Wallis test. RESULTS: An increase in the thickness of 0.5 mm reduced the ΔE00 of the HT samples to 72.8%, and that of the T samples to 71.1% (p < 0.0001). 7 substrates with HT and LT specimens had significantly different results from the mean (p < 0.05). A thickness of 0.5 mm is not sufficient to achieve an acceptable result at any level of translucency, while the low translucency ceramic at a thickness of 1.5 mm gave acceptable results, except for severely discoloured substrates (ND8 and ND9). CONCLUSIONS: The colour reproduction ability of lithium disilicate glass-ceramics is significantly affected by their translucency, layer thickness, and 7 substrates out of 9 substrates examined.


Asunto(s)
Cerámica , Color , Porcelana Dental , Porcelana Dental/química , Cerámica/química , Coloración de Prótesis , Espectrofotometría , Ensayo de Materiales , Humanos , Propiedades de Superficie
16.
BMC Oral Health ; 24(1): 670, 2024 Jun 08.
Artículo en Inglés | MEDLINE | ID: mdl-38851731

RESUMEN

OBJECTIVE: To investigate the fracture resistance and failure modalities of anterior endocrown restorations fabricated employing diverse ceramic materials, and bonded using various cementation methodologies. MATERIALS AND METHODS: Forty maxillary central incisors were divided into two main groups based on the ceramic materials used; GroupI (Zir): zirconia endocrwons (Zolid HT+, Ceramill, Amanngirrbach) and GroupII (E-Max): e-max endocrowns (IPS e.max CAD, Ivoclar Vivadent). Both groups were further split into two subgroups depending on the cementation protocols; subgroup IA "ZirMDP": endocowns cemented with MDP primer + MDP resin cement, subgroup IB (ZirNon-MDP): cemented with MDP primer + non-MDP resin cement, subgroup IIA (E-maxMDP): cemented with MDP primer + MDP resin cement, subgroup IIB (E-maxNon-MDP): cemented with MDP primer + non-MDP resin cement. (n = 10/subgroup). Endocrowns were manufactured using CAD/ CAM. Teeth were subjected to 10,000 thermal cycles. The fracture test was performed at 45o with a palatal force direction until the fracture occurred. Test results were recorded in Newton. The failure mode was examined using a stereomicroscope. A One-way ANOVA test was utilized to compare different groups regarding fracture strength values. Tukey`s Post Hoc was utilized for multiple comparisons. RESULTS: The comparative analysis of fracture strength across the diverse groups yielded non-significant differences, as indicated by a p-value exceeding 0.05. Nonetheless, an observable trend emerged regarding the mode of failure. Specifically, a statistically significant prevalence was noted in fractures localized within the endocrown/tooth complex below the cementoenamel junction (CEJ) across all groups, except for Group IIB, "E-max Non-MDP," where fractures within the endocrown/tooth complex occurred above the CEJ. CONCLUSIONS: Combining an MDP-based primer with an MDP-based resin cement did not result in a significant effect on the anterior endocrown fracture strength. CLINICAL RELEVANCE: Regardless of the presence of the MDP monomer in its composition, adhesive resin cement achieved highly successful fracture strength when used with MDP-based ceramic primers. Additionally, ceramic materials exhibiting elastic moduli surpassing those of dentin are discouraged due to their propensity to induce catastrophic fractures within the tooth structure.


Asunto(s)
Cementación , Análisis del Estrés Dental , Incisivo , Humanos , Cementación/métodos , Técnicas In Vitro , Cementos de Resina/química , Circonio/química , Ensayo de Materiales , Coronas , Fracaso de la Restauración Dental , Cerámica/química , Materiales Dentales/química , Diseño Asistido por Computadora , Porcelana Dental/química
17.
Acta Odontol Latinoam ; 37(1): 88-95, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38920130

RESUMEN

Glass ceramics are widely used to manufacture esthetic veneers, inlays, onlays, and crowns. Although the clinical survival rates ofglass-ceramic restorations arefavorable,fractures or chips are common. Certain cases can be repaired with direct composite. AIM: The aim of this study was to investigate the interaction effect of different designs and surface treatments on the load-to-failure of lithium disilicate glass-ceramic repaired with nanofilled composite. MATERIALS AND METHOD: Lithium-disilicate glass-ceramic slabs (IPS e.max Press, Ivoclar Vivadent) with three different designs of the top surface (flat, single plateau, or doubleplateau) (n=U) received 'no treatment', '5% HF etching', or "AI2O3 sandblasting". HF-etched and sandblasted slabs also received silane and universal one-step adhesive application. All slabs were incrementally repaired with nanofilled composite (Filtek Z350, 3M ESPE) up to6 mm above the highest ceramic top plateau. Specimens were stored in artificial saliva at 37 °C for 21 days and then subjected to 1,000 thermocycles between 5 and 55 °C. The interface composite-ceramic of each specimen was tensile tested until failure in a universal testing machine and the mode of failure was determined under a stereomicroscope. The ceramic surface morphology of one representative tested specimen from each subgroup (design/surface treatment) was observed through scanning electron microscopy (SEM). RESULTS: Regardless of ceramic design, the absence of surface treatment resulted in significantly lower load-to-failure values. No significant differences in load-to-failure values were observed between HF-etched and sandblasted specimens for the flat design; however, HF etching resulted in significantly higher load-to-failure values than sandblasting for both single plateau and double plateau designs. The majority (60%) of HF-etched specimens with single plateau or double plateau presented mixed failures. SEM photomicrographs showed that HF-etched specimens had smoother surfaces than sandblasted specimens. CONCLUSION: The surface treatment of a defective lithium disilicate glass-ceramic restoration has more influence than its macroscopic design on the retention of the composite repair. HF etching seems to provide higher bond strength to the composite repair.


Embora fraturas e lascamento de restauragoes vitrocerámicas sejam comuns, alguns casos podem ser reparados com compósito direto. OBJETIVO: investigar o efeito da interagao de diferentes formas e tratamentos de superficie na carga de ruptura de uma vitrocerámica reforgada com dissilicato de litio reparada com compósito nanoparticulado. MATERIAIS E MÉTODOS: A superficie superior de espécimes de vitroceramica (IPS e.max Press, Ivoclar Vivadent) foi preparada com tres formas (plana, plato único, ou duplo) e recebeu (n=11): 'nenhum tratamento', 'condicionamento com ácido hidrofluoridrico 5%', ou 'jateamento com AfOf. Ambos espécimes condicionados e jateados receberam silano e adesivo universal. Todos os espécimes foram reparados incrementalmente com compósito (Filtek Z350, 3M ESPE) até6 mm acima do plato cerámico mais alto, armazenados em saliva artificial á 37 °C por 21 dias, e submetidos á 1.000 termociclos (5 e 55 °C). A interface compósito-cerámica de cada amostra foi testada á tragao até sua falha em máquina universal e o modo de falha foi determinado com estereomicroscópio. A morfologia da superficie de uma amostra representativa de forma/tratamento de superficie foi observada através de microscopia eletronica de varredura (MEV). RESULTADOS: Independentemente da forma ceramica, a ausencia de tratamento superficial resultou em valores de carga de ruptura significativamente menores. Nao foi observada differenga significativa entre os espécimes planos condicionados ou jateados; no entanto, o condicionamento resultou em valores significativamente maiores que o jateamento para espécimes com plato único e duplo. A maioria (60%) dos espécimes condicionados e com plato único ou duplo apresentou falhas mistas. Imagens SEM demonstraram rugosidade superficial mais regular dos espécimes condicionados que os jateados. CONCLUSÕES: O tratamento superficial de uma restauragao defeituosa de vitrocerámica reforgada por dissilicato de litio tem maior influencia na retengao do reparo de compósito do que sua forma macroscópica; ainda, o condicionamento com ácido hidrofluoridrico parece proporcionar maior resistencia de uniao ao reparo com compósito.


Asunto(s)
Cerámica , Porcelana Dental , Propiedades de Superficie , Cerámica/química , Porcelana Dental/química , Ensayo de Materiales , Fracaso de la Restauración Dental , Resinas Compuestas/química , Análisis del Estrés Dental , Diseño de Prótesis Dental
18.
Dent Mater ; 40(8): 1267-1281, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38876830

RESUMEN

OBJECTIVES: During the manufacturing of Porcelain Veneered Zirconia (PVZ) dental crowns, the veneer-core system undergoes high-temperature firing cycles and gets fused together which is then, under a controlled setting, cooled down to room temperature. During this cooling process, the mismatch in thermal properties between zirconia and porcelain leads to the development of transient and residual thermal stresses within the crown. These thermal stresses are inherent to the PVZ dental crown systems and render the crown structure weak, acting as a precursor to veneer chipping, fracture, and delamination. In this study, the introduction of an intermediate functionally graded material (FGM) layer at the bi-material interface is investigated as a potentially viable alternative for providing a smoother transition of properties between zirconia and porcelain in a PVZ crown system. METHODS: Anatomically correct 3D crown models were developed for this study, with and without the FGM layer modeled at the bi-material interface. A viscoelastic finite element model was developed and validated for an anatomically correct bilayer PVZ crown system which was then used for predicting residual and transient stresses in the bilayer PVZ crown. Subsequently, the viscoelastic finite element model was further extended for the analysis of graded sublayers within the FGM layer, and this extended model was used for predicting the residual and transient stresses in the functionally graded PVZ crown, with an FGM layer at the bi-material interface. RESULTS: The study showed that the introduction of an FGM layer at the bi-material interface has the potential to reduce the effects from transient and residual stresses within the PVZ crown system relative to a bilayer PVZ crown structure. Furthermore, the study revealed that the FGM layer causes stress redistribution to alleviate the stress concentration at the interfacial surface between porcelain and zirconia which can potentially enhance the durability of the PVZ crowns towards interfacial debonding or fracture. SIGNIFICANCE: Thus, the use of an FGM layer at the bi-material interface shows a good prospect for enhancing the longevity of the PVZ dental crown restorations by alleviating the abrupt thermal property difference and relaxing thermal stresses.


Asunto(s)
Coronas , Porcelana Dental , Coronas con Frente Estético , Análisis de Elementos Finitos , Circonio , Circonio/química , Porcelana Dental/química , Ensayo de Materiales , Viscosidad , Elasticidad , Propiedades de Superficie , Análisis del Estrés Dental , Diseño de Prótesis Dental , Materiales Dentales/química
19.
Dent Mater J ; 43(4): 504-516, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38825449

RESUMEN

The surface treatment of glass-ceramic-based materials, namely, lithium disilicate glass (IPS e.max CAD), feldspar porcelain (VITABLOCS Mark II), and a polymer-infiltrated ceramic network (VITA ENAMIC), using aqueous fluoride solutions and their influence on luting agent bonding were investigated. Six experimental aqueous fluoride solutions were applied to these materials, and their effects were assessed by surface topological analysis. The obtained results were compared using non-parametric statistical analyses. Ammonium hydrogen fluoride (AHF) etchant demonstrated the greatest etching effect. Subsequent experiments focused on evaluating different concentrations of the AHF etchant for the bonding pretreatment of glass-ceramic-based materials with a luting agent (PANAVIA V5). AHF, particularly at concentrations above 5 wt%, effectively roughened the surfaces of the materials and improved the bonding performance. Notably, AHF at a concentration of 30 wt% exhibited a more pronounced effect on both etching and bonding capabilities compared to hydrofluoric acid.


Asunto(s)
Cerámica , Diseño Asistido por Computadora , Porcelana Dental , Fluoruros , Ácido Fluorhídrico , Ensayo de Materiales , Propiedades de Superficie , Fluoruros/química , Cerámica/química , Porcelana Dental/química , Ácido Fluorhídrico/química , Recubrimiento Dental Adhesivo/métodos , Grabado Ácido Dental , Silicatos de Aluminio/química , Compuestos de Potasio/química , Compuestos de Amonio/química
20.
Clin Oral Investig ; 28(7): 370, 2024 Jun 13.
Artículo en Inglés | MEDLINE | ID: mdl-38869624

RESUMEN

OBJECTIVES: To investigate the effect of multiple firings on color, translucency, and biaxial flexure strength of Virgilite-containing (Li0.5Al0.5Si2.5O6) lithium disilicate glass ceramics of varying thickness. MATERIALS AND METHODS: Sixty discs were prepared from Virgilite-containing lithium disilicate blocks. Discs were divided according to thickness (n = 30) into T0.5 (0.5 mm) and T1.0 (1.0 mm). Each thickness was divided according to the number of firing cycles (n = 10); F1 (Control group): 1 firing cycle; F3: 3 firing cycles, and F5: 5 firing cycles. The discs were tested for color change (ΔE00) and translucency (TP00) using a spectrophotometer. Then, all samples were subjected to biaxial flexure strength testing using a universal testing machine. Data were collected and statistically analyzed (α = 0.5). For chemical analysis, six additional T0.5 discs (2 for each firing cycle) were prepared; for each firing cycle one disc was subjected to X-ray diffraction analysis (XRD) and another disc was subjected to Energy dispersive X-ray spectroscopy (EDX) and Scanning electron microscope (SEM). RESULTS: Repeated firing significantly reduced the translucency of F3 and F5 compared to F1 in T0.5 (p < 0.001), while for T1.0 only F5 showed a significant decrease in TP00 (p < 0.001). For ΔE00, a significant increase was recorded with repeated firings (p < 0.05) while a significant decrease resulted in the biaxial flexure strength regardless of thickness. CONCLUSIONS: Repeated firings had a negative effect on both the optical and mechanical properties of the Virgilite-containing lithium disilicate glass ceramics. CLINICAL RELEVANCE: Repeated firings should be avoided with Virgilite-containing lithium disilicate ceramics to decrease fracture liability and preserve restoration esthetics.


Asunto(s)
Cerámica , Porcelana Dental , Resistencia Flexional , Ensayo de Materiales , Propiedades de Superficie , Difracción de Rayos X , Cerámica/química , Porcelana Dental/química , Color , Análisis del Estrés Dental , Espectrofotometría , Microscopía Electrónica de Rastreo , Calor
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...