Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 594
Filtrar
1.
Acta Orthop ; 95: 386-391, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016083

RESUMEN

BACKGROUND AND PURPOSE: There is controversy regarding the results of stemmed and stemless total shoulder arthroplasty (TSA) used for osteoarthritis. Therefore, we aimed to compare revision rates of stemmed and stemless TSA and to examine the impact of metal-backed glenoid components. METHODS: We included all patients reported to the Danish Shoulder Arthroplasty Register from January 1, 2012 to December 31, 2022 with an anatomical TSA used for osteoarthritis. Primary outcome was revision (removal or exchange of components) for any reason. RESULTS: 3,338 arthroplasties were included. The hazard ratio for revision of stemless TSA adjusted for age and sex was 1.83 (95% confidence interval [CI] 1.21-2.78) with stemmed TSA as reference. When excluding all arthroplasties with a metal-backed glenoid component, the adjusted hazard ratio for revision of stemless TSA was 1.37 (CI 0.85-2.20). For the Eclipse stemless TSA system, the adjusted hazard ratio for revision of a metal-backed glenoid component was 8.75 (CI 2.40-31.9) with stemless Eclipse with an all-polyethylene glenoid component as reference. CONCLUSION:  We showed that the risk of revision of stemless TSAs was increased and that it was related to their combination with metal-backed glenoid components.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Osteoartritis , Diseño de Prótesis , Falla de Prótesis , Sistema de Registros , Reoperación , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Reoperación/estadística & datos numéricos , Masculino , Femenino , Anciano , Dinamarca/epidemiología , Persona de Mediana Edad , Osteoartritis/cirugía , Estudios de Cohortes , Articulación del Hombro/cirugía , Anciano de 80 o más Años , Metales
2.
Bioinspir Biomim ; 19(4)2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38848735

RESUMEN

Shoulder joints determine the motion range of the upper limb. Thus, the compact and well-stiffened spherical parallel mechanism (SPM) has emerged as the mainstream shoulder prosthesis design approaches. However, the SPM's moving pairs of redundant motions impose excessive constraints that limit its workspace. Therefore, amplifying the workspace of the SPM to cover the motion range required by human daily activities is a pressing problem in shoulder prosthesis design. To address this challenge, this study proposed a workspace amplification approach through the kinematic analysis of a symmetrically arranged 2 degrees of freedom (DoFs) passive mechanism, together with the designed and optimized 3-RRR SPM, to construct an anthropomorphic shoulder. The effectiveness and reliability of the proposed mechanism was verified through thorough analyses. Simulation and experiment results demonstrated that the workspace amplification mechanism could significantly increase the maximum motion match index between the shoulder prosthesis and the daily workspace of the human shoulder from only 26.3% to 94.79%, solving the problem that the traditional SPM-based prostheses cannot satisfy the motion range required by daily activities. Moreover, the proposed mechanism has the potential to amplify the workspace of most parallel mechanisms with multiple DoFs after proper modification.


Asunto(s)
Diseño de Prótesis , Rango del Movimiento Articular , Articulación del Hombro , Humanos , Fenómenos Biomecánicos , Rango del Movimiento Articular/fisiología , Articulación del Hombro/fisiología , Simulación por Computador , Prótesis de Hombro , Hombro/fisiología
3.
J Bone Joint Surg Am ; 106(13): 1181-1188, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38758820

RESUMEN

BACKGROUND: Controversy exists regarding the ideal humeral component version to optimize humeral rotation and patient outcomes in reverse total shoulder arthroplasty (rTSA). METHODS: Patients undergoing primary rTSA for rotator cuff tear arthropathy, a massive rotator cuff tear, or primary osteoarthritis with a rotator cuff tear were randomized to placement of the humeral component in neutral version or 30° of retroversion. Shoulder active range of motion and strength and visual analog scale (VAS) pain, American Shoulder and Elbow Surgeons (ASES), and Patient-Reported Outcomes Measurement Information System Global 10 (PROMIS-10) scores were collected up to 2 years postoperatively. The goal of the study was to determine whether humeral external rotation and internal rotation are affected by humeral component version following rTSA at 2 years postoperatively. RESULTS: Sixty-six patients were included in the analysis. The median follow-up was 26 months for the neutral and 27 months for the 30° retroversion group. No differences between the groups were observed with respect to the primary diagnosis, sex, age, body mass index, or American Society of Anesthesiologists (ASA) class. The 2 groups did not differ significantly in terms of improvement at 2 years in active shoulder abduction (p = 0.969), forward elevation (p = 1.000), internal rotation measured as the highest spinal level reached (p = 1.000), internal rotation with the arm abducted 90° (p = 0.451), external rotation (p = 0.362), or muscle strength in forward elevation (p = 1.000), abduction (p = 1.000), external rotation (p = 0.617), or internal rotation (p = 1.000). The 2 groups did not differ significantly in terms of improvement in postoperative ASES (p = 1.000), PROMIS-10 physical (p = 1.000), or VAS pain scores (p = 0.718) at the time of final follow-up. In the neutral version group, 1 patient underwent revision for instability and 1 for stiffness. One acromial stress fracture occurred in the 30° humeral retroversion group. Scapular notching was observed in 7 (21.2%) of the patients in neutral version group and 5 (15.2%) of the patients in the 30° retroversion group (p = 0.750). CONCLUSIONS: Securing the humeral component at neutral version or 30° of retroversion in rTSA resulted in similar active shoulder external rotation, internal rotation, forward elevation, abduction, and strength measurements, complication rates, and VAS pain, PROMIS-10 physical, and ASES scores at 2 years postoperatively. LEVEL OF EVIDENCE: Therapeutic Level I . See Instructions for Authors for a complete description of levels of evidence.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Rango del Movimiento Articular , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Masculino , Femenino , Anciano , Estudios Prospectivos , Método Doble Ciego , Persona de Mediana Edad , Resultado del Tratamiento , Húmero/cirugía , Lesiones del Manguito de los Rotadores/cirugía , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Artropatía por Desgarro del Manguito de los Rotadores/cirugía , Osteoartritis/cirugía , Osteoartritis/fisiopatología , Prótesis de Hombro , Medición de Resultados Informados por el Paciente , Dimensión del Dolor
4.
J Bone Joint Surg Am ; 106(13): 1221-1230, 2024 Jul 03.
Artículo en Inglés | MEDLINE | ID: mdl-38776388

RESUMEN

➤ No single test has demonstrated absolute accuracy for the diagnosis of periprosthetic joint infection (PJI).➤ Physicians rely on a combination of serological tests, synovial markers, and clinical findings plus clinical judgment to help to guide preoperative decision-making.➤ Several organizations have proposed criteria for the diagnosis of hip or knee PJI on which we now rely.➤ Given that shoulder arthroplasty has only recently become popular, it is possible that a shoulder-specific definition of PJI will be introduced in the coming years.➤ Although a number of serum and synovial markers have demonstrated high accuracy for the diagnosis of PJI of the hip and knee, further research is needed in order to identify markers that may be more suitable for the diagnosis of shoulder PJI and for the potential development and identification of specific serological tests as screening tools for PJI.


Asunto(s)
Algoritmos , Biomarcadores , Infecciones Relacionadas con Prótesis , Humanos , Infecciones Relacionadas con Prótesis/diagnóstico , Infecciones Relacionadas con Prótesis/sangre , Biomarcadores/sangre , Biomarcadores/análisis , Líquido Sinovial/química , Prótesis de Hombro/efectos adversos , Artroplastía de Reemplazo de Hombro/efectos adversos , Artroplastia de Reemplazo de Rodilla/efectos adversos , Prótesis de la Rodilla/efectos adversos , Prótesis de Cadera/efectos adversos , Artroplastia de Reemplazo de Cadera/efectos adversos
8.
Arch Orthop Trauma Surg ; 144(5): 2093-2099, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38653836

RESUMEN

OBJECTIVE: The objective of this study was to evaluate clinical and radiological outcomes of a short stem reverse shoulder prosthesis with metaphyseal fixation specifically in older patients. METHODS: All patients, older than 70 years, submitted to a Reverse Shoulder Arthroplasty (RSA) using a cementless onlay short stem (Aequalis Ascend™ Flex Convertible Shoulder System (Stryker®)) from January 2017 to December 2021, with a minimum follow-up of 2 years, were included. Postoperative radiographs were assessed for stem loosening, subsidence, and varus-valgus tilt. Range of motion, visual analogue scale for pain, constant score, complication rate and revision rate were also analysed. RESULTS: A total of 34 patients with a mean age of 75 years (range 71-83 years) were submitted to a cementless onlay short stem RSA with a Bone Increased Off-Set (BIO-RSA) construct. The mean follow-up period was 61 months (range 54-87). Significant improvements (p < 0.001) were observed for the constant score and range of motion from the preoperative state to final follow-up. One case exhibited a significant varus deviation (> 5˚) during the follow-up period. No case of stem loosening was identified. There was only one case of complication because of post-traumatic dislocation, but the stem didn't need revision. CONCLUSION: Short stem RSA, even in patients older than 70 years, can yield a stable fixation with a good clinical and radiological outcome at short-medium term follow-up. LEVEL OF EVIDENCE: Level III; Retrospective Study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Diseño de Prótesis , Prótesis de Hombro , Humanos , Anciano , Artroplastía de Reemplazo de Hombro/métodos , Anciano de 80 o más Años , Femenino , Masculino , Rango del Movimiento Articular , Estudios Retrospectivos , Radiografía , Resultado del Tratamiento , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen
9.
Eur J Orthop Surg Traumatol ; 34(4): 2137-2145, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38557891

RESUMEN

PURPOSE: When compared to standard-length humeral stem in reverse total shoulder arthroplasty (RTSA), short humeral stems in RTSA require good proximal humeral metaphyseal bone quality to gain proper and secure fixation during prosthetic implantation. Shorter humeral stems potentially carry more risk of misalignment than standard or long humeral stems. The hypothesis was that misalignment of the short humeral stems is influenced by regional bone quality. METHODS: RTSA with a short curved humeral stem with neck-shaft angle (NSA) default of 132.5° was reviewed. The study group included 35 cases at a mean age of 75.97 (± 6.23) years. Deltoid-tuberosity index (DTI) was measured to evaluate proximal humeral bone quality. The deltoid tuberosity index was measured at immediately above position of the upper end of the deltoid tuberosity. Stem alignment was given by the angle measured in degrees between the intramedullary humeral shaft axis and the axis of the humeral implant stem. RESULTS: The patient's mean DTI was 1.37 ± 0.16 (median, 1.32; range, 1.12-1.80). 22 patients had poor bone quality (DTI < 1.4), compared to 13 patients with acceptable bone quality (DTI > 1.4). After RTSA, ten humeral components (29%) were neutrally aligned, whereas 25 humeral components (71%) were misaligned. There was no correlation between misalignment and DTI (r = 0.117; p = 0.504). But there was a strong correlation between misalignment and the patient's own NSA (r = - 0.47; p = 0.004). The postoperative stem position and stem misalignment are not associated with functional outcomes (p > 0.05). CONCLUSION: The misalignment of the short curved humeral stem frequently occurs. Poor reginal humeral bone quality does not influence misalignment after RTSA with a short humeral stem. Postoperative stem alignment is associated with the patient's preoperative NSA and method of neck cut. The misalignment does not affect functional outcomes for midterm follow-up. Further long-term follow-up studies are needed to confirm its clinical relevance.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Húmero , Diseño de Prótesis , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/efectos adversos , Anciano , Húmero/cirugía , Húmero/diagnóstico por imagen , Masculino , Femenino , Prótesis de Hombro/efectos adversos , Anciano de 80 o más Años , Articulación del Hombro/cirugía , Articulación del Hombro/fisiopatología , Estudios Retrospectivos
11.
J Shoulder Elbow Surg ; 33(8): 1873-1883, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38604399

RESUMEN

BACKGROUND: Allograft prosthetic composite (APC) reconstruction is performed after resection of proximal humerus tumors or failure of arthroplasty implants. There is limited literature on the postoperative outcomes of this technique. We sought to assess implant survival, failure rates, and postoperative functional outcomes after APC reconstruction of the proximal humerus. METHODS: A systematic review of the PubMed and Embase databases was conducted. The study was registered on PROSPERO (ID: 448,663). The Strengthening of the Reporting of Observational Studies in Epidemiology checklist was used for quality assessment. Implant failure was determined using the Henderson classification for biological reconstruction. Functional outcome was primarily assessed using the Musculoskeletal Tumor Society score at last follow-up. RESULTS: Twenty-five studies with a total of 488 patients were included. Mean follow-up in reporting studies ranged from 2.5 to 10 years. Five-year revision-free survival for implants ranged from 41% to 92%. Overall implant failure rate ranged from 9% to 54%, and reoperation rate ranged from 0% to 55%. Graft host nonunion (type 2) was the most common mode of failure, with rates ranging from 0% to 75%. The mean Musculoskeletal Tumor Society scores at last follow-up ranged from 57% to 90% across studies. A trend towards better functional outcomes was seen in patients having an APC with a reverse total shoulder arthroplasty (rTSA) compared with those with hemiarthroplasty. CONCLUSIONS: APCs show promise in proximal shoulder reconstruction, with heterogeneous functional outcomes that are noninferior to other reconstruction techniques. Graft host nonunion is a common mode of failure and remains a concern in this type of prosthesis. Future studies should compare rTSA-APCs and rTSA endoprostheses while controlling for potential confounders.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Húmero/cirugía , Neoplasias Óseas/cirugía , Complicaciones Posoperatorias/epidemiología , Falla de Prótesis , Prótesis de Hombro , Aloinjertos , Articulación del Hombro/cirugía , Reoperación/estadística & datos numéricos , Resultado del Tratamiento
12.
Clin Orthop Surg ; 16(2): 303-312, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38562639

RESUMEN

Background: Glenoid position and inclination are important factors in protecting against scapular notching, which is the most common complication that directly affects the longevity of reverse shoulder arthroplasty (RSA). This study aimed to investigate the biomechanical characteristics of glenosphere orientation, comparing neutral tilt, inferior overhang with an eccentric glenosphere at the same placement of baseplate, and inferior tilt after 10° inferior reaming in the lower part of the glenoid in RSA. Methods: Nine cadaveric shoulders were tested with 5 combinations of customized glenoid components: a centric glenosphere was combined with a standard baseplate (group A); an eccentric glenosphere to provide 4-mm inferior overhang than the centric glenosphere was combined with a standard baseplate (group B); a centric glenosphere was combined with a wedge-shaped baseplate tilted inferiorly by 10° with the same center of rotation (group C); an eccentric glenosphere was attached to a wedge-shaped baseplate (group D); and 10° inferior reaming was performed on the lower part of the glenoid to apply 10° inferior tilt, with a centric glenosphere secured to the standard baseplate for simulation of clinical tilt (group E). Impingement-free angles for adduction, abduction, forward flexion, external rotation, and internal rotation were measured. The capability of the deltoid moment arm for abduction and forward flexion, deltoid length, and geometric analysis for adduction engagement were evaluated. Results: Compared with neutral tilt, inferior tilt at the same position showed no significant difference in impingement-free angle, moment arm capability, and deltoid length. However, group D resulted in better biomechanical properties than a central position, regardless of inferior tilt. Group E demonstrated a greater range of adduction, internal and external rotation, and higher abduction and forward flexion capability with distalization, compared to corresponding parameters for inferior tilt with a customized wedge-shaped baseplate. Conclusions: A 10° inferior tilt of the glenosphere, without changing the position of the baseplate, had no benefit in terms of the impingement-free angle and deltoid moment arm. However, an eccentric glenosphere had a significant advantage, regardless of inferior tilt. Inferior tilt through 10° inferior reaming showed better biomechanical results than neutral tilt due to the distalization effect.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/cirugía , Hombro/cirugía , Escápula , Rango del Movimiento Articular , Fenómenos Biomecánicos
13.
Bone Joint J ; 106-B(5): 482-491, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38688478

RESUMEN

Aims: Metal and ceramic humeral head bearing surfaces are available choices in anatomical shoulder arthroplasties. Wear studies have shown superior performance of ceramic heads, however comparison of clinical outcomes according to bearing surface in total shoulder arthroplasty (TSA) and hemiarthroplasty (HA) is limited. This study aimed to compare the rates of revision and reoperation following metal and ceramic humeral head TSA and HA using data from the National Joint Registry (NJR), which collects data from England, Wales, Northern Ireland, Isle of Man and the States of Guernsey. Methods: NJR shoulder arthroplasty records were linked to Hospital Episode Statistics and the National Mortality Register. TSA and HA performed for osteoarthritis (OA) in patients with an intact rotator cuff were included. Metal and ceramic humeral head prostheses were matched within separate TSA and HA groups using propensity scores based on 12 and 11 characteristics, respectively. The primary outcome was time to first revision and the secondary outcome was non-revision reoperation. Results: A total of 4,799 TSAs (3,578 metal, 1,221 ceramic) and 1,363 HAs (1,020 metal, 343 ceramic) were included. The rate of revision was higher for metal compared with ceramic TSA, hazard ratio (HR) 3.31 (95% confidence interval (CI) 1.67 to 6.58). At eight years, prosthesis survival for ceramic TSA was 98.7% (95% CI 97.3 to 99.4) compared with 96.4% (95% CI 95.2 to 97.3) for metal TSA. The majority of revision TSAs were for cuff insufficiency or instability/dislocation. There was no significant difference in the revision rate for ceramic compared with metal head HA (HR 1.33 (95% CI 0.76 to 2.34)). For ceramic HA, eight-year prosthetic survival was 92.8% (95% CI 86.9 to 96.1), compared with 91.6% (95% CI 89.3 to 93.5) for metal HA. The majority of revision HAs were for cuff failure. Conclusion: The rate of all-cause revision was higher following metal compared with ceramic humeral head TSA in patients with OA and an intact rotator cuff. There was no difference in the revision rate for HA according to bearing surface.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cerámica , Hemiartroplastia , Diseño de Prótesis , Falla de Prótesis , Reoperación , Prótesis de Hombro , Humanos , Reoperación/estadística & datos numéricos , Hemiartroplastia/métodos , Masculino , Femenino , Artroplastía de Reemplazo de Hombro/métodos , Anciano , Persona de Mediana Edad , Osteoartritis/cirugía , Sistema de Registros , Cabeza Humeral/cirugía , Anciano de 80 o más Años , Metales
14.
JBJS Rev ; 12(4)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38574183

RESUMEN

¼ Reverse total shoulder arthroplasty was designed to function in the rotator cuff deficient shoulder by adjusting the glenohumeral center of rotation (COR) to maximize deltoid function.¼ Adjustments in the COR ultimately lead to changes in resting tension of the deltoid and remaining rotator cuff, which can affect implant stability and risk of stress fracture.¼ Soft-tissue balance and complication profiles can be affected by humeral component (version, neck shaft angle, and inlay vs. onlay) and glenoid component (sagittal placement, version, inclination, and lateralization) design and application.¼ A good understanding of the effects on soft-tissue balance and complication profile is critical for surgeons to best provide optimal patient outcomes.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/efectos adversos , Articulación del Hombro/cirugía , Hombro/cirugía , Prótesis de Hombro/efectos adversos , Manguito de los Rotadores/cirugía
15.
J Shoulder Elbow Surg ; 33(6S): S43-S48, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38554996

RESUMEN

BACKGROUND: Humeral implant designs for anatomic total shoulder arthroplasty (aTSA) focus on anatomic reconstruction of the articular segment. Likewise, the pathoanatomy of advanced glenohumeral osteoarthritis often results in humeral head deformity. We hypothesized the anatomic reconstruction of the humeral head in aTSA risks overstuffing the glenohumeral joint. METHODS: Ninety-seven cases (52 females) of primary glenohumeral osteoarthritis in patients treated with aTSA were evaluated. Preoperative computed tomography scans were used to classify glenoid morphology according to the Walch classification. Coronal plane images in the plane of the humerus were used to determine the anatomic best-fit circle as described by Youderian et al. Humeral head thinning was determined as the distance from the center of rotation of the best-fit circle to the nearest point along the humeral articular surface. aTSA was modeled with a predicted anatomic humeral head and a simulated 4-mm polyethylene glenoid component. The change in the position of the native humerus was determined. Wilcoxon Rank Sum tests were used to evaluate differences in humeral head thinning and humeral lateralization between monoconcave and biconcave glenoid morphologies. Spearman's rank correlation coefficients were used to assess the relationship between humeral head thinning with preoperative active forward elevation and external rotation. RESULTS: The mean radius of the best-fit circle was 25.0 ± 2.1 mm. There was a mean thinning of 2.4 ± 2.0 mm (range -1.7 to 8.3). The mean percent thinning of the humeral head was 9.4% ± 7.7%. The mean humeral lateralization was 6.4 ± 2.0 mm. Humeral head thinning was not significantly associated with active forward elevation (r = -0.15, P = .14) or active external rotation (r = -0.12, P = .25). There were no significant differences in the percentage of humeral head thinning (P = .324) or humeral lateralization (P = .350) between concentric and eccentric glenoid wear patterns. CONCLUSIONS: Utilization of the best-fit circle as a guide in aTSA may risk excessive lateralization of the humerus and overstuffing the glenohumeral joint. This may have implications for subscapularis repair and healing, as well as glenoid implant and rotator cuff longevity. These findings call into question whether recreation of normal glenohumeral anatomy in aTSA is appropriate for all patients. Humeral head reconstruction in aTSA should account for glenohumeral joint volume and soft tissue contracture.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Cabeza Humeral , Osteoartritis , Diseño de Prótesis , Articulación del Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Cabeza Humeral/diagnóstico por imagen , Cabeza Humeral/cirugía , Cabeza Humeral/anatomía & histología , Masculino , Anciano , Osteoartritis/cirugía , Osteoartritis/diagnóstico por imagen , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/anatomía & histología , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Prótesis de Hombro , Estudios Retrospectivos , Rango del Movimiento Articular , Anciano de 80 o más Años
16.
Arch Orthop Trauma Surg ; 144(5): 1925-1935, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38523239

RESUMEN

BACKGROUND: Patients who undergo reverse total shoulder arthroplasty (RTSA) are getting younger with greater function expectations. This retrospective, longitudinal study of prospectively collected data compared perceived shoulder function and strength, active shoulder mobility, radiographic evidence of scapular notching, and implant survival over the initial 2-years post-RTSA among patient groups who received either standard central fixation point liner and glenoid baseplate implants, or lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants. MATERIALS AND METHODS: Patients who underwent primary RTSA using standard central fixation point liner and glenoid baseplate implants (Group 1, n = 180) were compared with patients who underwent primary RTSA using lower size profile mini-humeral tray with offset trunnion options and mini-augmented glenoid baseplate implants (Group 2, n = 53) for active shoulder mobility, American Shoulder and Elbow Surgeons (ASES) score, perceived ability to lift 10 lbs (4.5 kg) overhead, radiographic evidence of scapular notching, and implant survival. Data was collected pre-surgery, 6-weeks, 6-months, 1-year, and 2-years post-RTSA (p ≤ 0.05). RESULTS: More Group 2 patients had more complex B or C Walch glenoid morphology, while Group 1 had more A1 or A2 types (p ≤ 0.001). Group 2 had greater active shoulder flexion at 6-months, 1-year, and 2-years (p ≤ 0.018) and external rotation (in adduction) at 6-months and 2-years (p ≤ 0.004) compared to Group 1, with higher ASES scores at 6-months and 2-years (p ≤ 0.026) (with small-to-medium effect sizes), and with more patients meeting or exceeding the minimal clinically important difference (MCID) at 2-years (p = 0.045) and patient acceptable symptomatic state (PASS) levels at 6-months, 1-year and 2-years (p ≤ 0.045). Scapular notching was identified in six of 53 (11.3%) Group 2 patients and in 32 of 180 (17.7%) Group 1 patients. Group 1 patients had more grade 2 or greater scapular notching grades compared to Group 2 (p = 0.04). Implant survival was comparable with Group 1 = eight of 180 (4.4%) and Group 2 = 1 of 53 (1.9%) of patients requiring removal for 95.6% and 98.1% implant survival, respectively. CONCLUSION: Limited scapular notching and excellent implant survival was observed in both groups. Despite including individuals with more complex glenoid deficiency, patients receiving the lower size profile implants generally displayed better active shoulder mobility and perceived shoulder function compared to those who received standard implants. These patients also more frequently met or exceeded the MCID by 2-years post-RTSA and PASS levels by 6-months, 1-year, and 2-years post-RTSA, with lower scapular notching grades. LEVEL OF EVIDENCE: Retrospective comparative study.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Artroplastía de Reemplazo de Hombro/instrumentación , Estudios Retrospectivos , Masculino , Anciano , Femenino , Persona de Mediana Edad , Articulación del Hombro/cirugía , Diseño de Prótesis , Estudios Longitudinales , Húmero/cirugía , Rango del Movimiento Articular , Anciano de 80 o más Años
17.
BMC Musculoskelet Disord ; 25(1): 204, 2024 Mar 07.
Artículo en Inglés | MEDLINE | ID: mdl-38454432

RESUMEN

BACKGROUND: The two major reverse shoulder arthroplasty (RSA) designs are the Grammont design and the lateralized design. Even if the lateralized design is biomechanically favored, the classic Grammont prosthesis continues to be used. Functional and subjective patient scores as well as implant survival described in the literature so far are comparable to the lateralized design. A pure comparison of how the RSA design influences outcome in patients has not yet been determined. The aim of this study was a comparison focused on patients with cuff tear arthropathy (CTA). METHODS: We analyzed registry data from 696 CTA patients prospectively collected between 2012 and 2020 in two specialized orthopedic centers up to 2 years post-RSA with the same follow-up time points (6,12 24 months). Complete teres minor tears were excluded. Three groups were defined: group 1 (inlay, 155° humeral inclination, 36 + 2 mm eccentric glenosphere (n = 50)), group 2 (inlay, 135° humeral inclination, 36 + 4 mm lateralized glenosphere (n = 141)) and group 3 (onlay, 145° humeral inclination, + 3 mm lateralized base plate, 36 + 2 mm eccentric glenosphere (n = 35)) We compared group differences in clinical outcomes (e.g., active and passive range of motion (ROM), abduction strength, Constant-Murley score (CS)), radiographic evaluations of prosthetic position, scapular anatomy and complications using mixed models adjusted for age and sex. RESULTS: The final analysis included 226 patients. The overall adjusted p-value of the CS for all time-points showed no significant difference (p = 0.466). Flexion of group 3 (mean, 155° (SD 13)) was higher than flexion of group 1 (mean, 142° (SD 18) and 2 (mean, 132° (SD 18) (p < 0.001). Values for abduction of group 3 (mean, 145° (SD 23)) were bigger than those of group 1 (mean, 130° (SD 22)) and group 2 (mean, 118° (SD 25)) (p < 0.001). Mean external rotation for group 3 (mean, 41° (SD 23)) and group 2 (mean, 38° (SD 17)) was larger than external rotation of group 1 (mean, 24° (SD 16)) (p < 0.001); a greater proportion of group 2 (78%) and 3 (69%) patients reached L3 level on internal rotation compared to group 1 (44%) (p = 0.003). Prosthesis position measurements were similar, but group 3 had significantly less scapular notching (14%) versus 24% (group 2) and 50% (group 1) (p = 0.001). CONCLUSIONS: Outcome scores of different RSA designs for CTA revealed comparable results. However, CTA patients with a lateralized and distalized RSA configuration were associated with achieving better flexion and abduction with less scapular notching. A better rotation was associated with either of the lateralized RSA designs in comparison with the classic Grammont prosthesis. LEVEL OF EVIDENCE: Therapeutic study, Level III.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Artropatía por Desgarro del Manguito de los Rotadores , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/cirugía , Manguito de los Rotadores/cirugía , Diseño de Prótesis , Rango del Movimiento Articular , Resultado del Tratamiento , Estudios Retrospectivos
18.
Eur J Orthop Surg Traumatol ; 34(4): 1851-1863, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38431896

RESUMEN

INTRODUCTION: The purposes of this study were to analyze and compare the functional outcomes and radiological changes around the press-fit humeral components in two contemporary medialized reverse total shoulder arthroplasty (RTSA) systems at a minimum of 5-year follow-up. MATERIALS AND METHODS: Between December 2003 and December 2015, 249 consecutive RTSAs were performed at our hospital. Of these, 68 primary uncemented RTSA met our inclusion criteria. The Constant-Murley score (CMS), the modified Constant score, a visual analog scale (VAS) and active shoulder range of motion (ROM) were measured pre- and postoperatively. Radiological assessment was performed by plain radiographs at a minimum of 5 years postoperatively. RESULTS: At a mean follow-up of 80.2 months, there was no significant difference (p = .59) between the postoperative functional scores and range of motion of the two groups (Delta Xtend and Lima SMR). Radiological data of stress-shielding were observed in 38 patients (55.9%) being slightly more frequent in the Lima SMR group (21 patients) than in the Delta Xtend group (17 patients) (p = .62). CONCLUSIONS: Our study shows that the good functional results are similar between the two uncemented RTSA systems used and that they do not depend on the presence of radiological changes (stress-shielding) in the humeral stem at a minimum 5-year follow-up.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Húmero , Radiografía , Rango del Movimiento Articular , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Femenino , Masculino , Estudios de Seguimiento , Anciano , Radiografía/métodos , Persona de Mediana Edad , Húmero/diagnóstico por imagen , Húmero/cirugía , Diseño de Prótesis , Resultado del Tratamiento , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Estudios Retrospectivos
19.
J Shoulder Elbow Surg ; 33(6S): S93-S103, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38492629

RESUMEN

BACKGROUND: Severe glenoid bone loss in the setting of both primary and revision reverse total shoulder arthroplasty (rTSA) continues to remain a significant challenge. The purpose of this study was to report on radiographic and clinical outcomes of primary and revision rTSA using a patient-matched, 3-dimensionally printed metal glenoid implant to address severe glenoid bone deficiency. This is a follow-up study to previously reported preliminary results. METHODS: A retrospective review was performed on 62 patients with severe glenoid bone deficiency who underwent either primary or revision rTSA using the Comprehensive Vault Reconstruction System (VRS) (Zimmer Biomet) at a single institution. Preoperative and postoperative values for the Disabilities of the Arm, Shoulder and Hand (DASH), Constant, American Shoulder and Elbow Surgeons Standardized Shoulder Assessment Form (ASES), Simple Shoulder Test (SST), Single Assessment Numeric Evaluation (SANE), and visual analog scale (VAS) pain scores as well as active range of motion (ROM) were collected and compared using the Wilcoxon signed rank test with the level of statistical significance set at P < .05. The percentage of patients achieving minimal clinically important difference (MCID) and substantial clinical benefit (SCB) was also calculated. RESULTS: Fifty-five of 62 shoulders (88.7%) were able to be contacted at a minimum of 2 years postoperatively, with 47 of 62 (75.8%) having complete clinical and radiographic follow-up with a mean age of 67.5 years (range, 48-85 years) and follow-up of 39.2 months (range, 25-56 months). There were 19 primary and 28 revision rTSAs. Significant improvements were seen in mean active forward flexion (63.1° ± 30.3° to 116.8° ± 35°), abduction (48.1° ± 16.1 to 76.2° ± 13.4°) (P < .001), external rotation (16° ± 23.7° to 32.1° ± 24.5°) (P < .005), DASH (59.9 ± 17.7 to 35.7 ± 24.3), Constant (23.4 ± 13.1 to 53.1 ± 17.4), ASES (27.8 ± 16.2 to 69.1 ± 25.2), SST (3.3 ± 2.5 to 7.6 ± 3.5), SANE (28.9 ± 18.3 to 66.7 ± 21.2), and VAS pain (7.1 ± 2.4 to 1.8 ± 2.6) scores (P < .001). MCID and SCB was achieved in a majority of patients postoperatively. The overall complication rate was 29.1%, with only 1 baseplate failure. CONCLUSION: This study demonstrates promising evidence that the VRS implant can be used as a viable option to achieve clinically important improvement in a majority of patients treated for severe glenoid bone deficiency with rTSA in both the primary and revision setting.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Diseño de Prótesis , Rango del Movimiento Articular , Reoperación , Articulación del Hombro , Prótesis de Hombro , Humanos , Artroplastía de Reemplazo de Hombro/métodos , Estudios Retrospectivos , Masculino , Femenino , Anciano , Reoperación/métodos , Persona de Mediana Edad , Articulación del Hombro/cirugía , Articulación del Hombro/diagnóstico por imagen , Articulación del Hombro/fisiopatología , Anciano de 80 o más Años , Resultado del Tratamiento , Estudios de Seguimiento
20.
J Shoulder Elbow Surg ; 33(6S): S86-S92, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38518886

RESUMEN

BACKGROUND: Aseptic humeral stem loosening is an uncommon complication of shoulder arthroplasty, and its presence has been considered a highly specific predictor of prosthetic joint infection (PJI). Literature on aseptic humeral stem loosening is sparse. The primary purpose of this study was to determine the rate of aseptic humeral loosening in revision shoulder arthroplasty. Secondarily, we sought to identify predictors of septic and aseptic humeral loosening. METHODS: Our institutional revision shoulder arthroplasty database was reviewed. Inclusion criteria were patients with humeral stem loosening as indicated in the operative report. Patient demographics, index surgery and indication, revision surgery and indication, and operative data were recorded. Charts were manually reviewed, and PJI scores were calculated using the International Consensus Meeting scoring criteria. International Consensus Meeting classifications of PJI "unlikely" and "possible" were considered aseptic, and PJI "probable" and "definite" were considered septic. Statistical analysis was performed to determine associations between the abovementioned variables and aseptic humeral loosening. RESULTS: Forty-six patients with 48 shoulders were included in our analysis. Ten cases (21%) were classified as definite PJI, 13 cases (27%) were classified as probable PJI, 4 cases (8%) were classified as possible PJI, and 21 cases (44%) were classified as PJI unlikely. On analysis of stem design, there were no statistically significant associations with aseptic loosening; although, a lack of proximal porous ingrowth surface trended toward higher rates of aseptic loosening in all patients and in anatomic total shoulder arthroplasty (ATSA) and reverse total shoulder arthroplasty (RTSA) subgroup analyses. In the index RTSA subgroup, aseptic loosening was associated with female sex (P = .005). Seventeen of 39 shoulders (44%) that underwent either index ATSA or RTSA demonstrated concomitant glenoid loosening. The absence of glenoid loosening was associated with aseptic humeral loosening in index ATSA and RTSA (P < .001). CONCLUSION: Fifty-two % of revision shoulder arthroplasty cases with humeral loosening performed at our institution were aseptic. There appear to be distinct demographic and radiographic factors that are more commonly associated with aseptic as opposed to septic humeral loosening. Our data demonstrate that demographic predictors of aseptic loosening of RTSA include female sex. The absence of glenoid component loosening is associated with aseptic humeral loosening and concomitant glenoid loosening is associated with septic humeral loosening. Understanding of these factors can guide the preoperative index of suspicion for PJI in the setting of humeral stem loosening.


Asunto(s)
Artroplastía de Reemplazo de Hombro , Falla de Prótesis , Infecciones Relacionadas con Prótesis , Reoperación , Prótesis de Hombro , Humanos , Femenino , Masculino , Anciano , Infecciones Relacionadas con Prótesis/etiología , Infecciones Relacionadas con Prótesis/cirugía , Artroplastía de Reemplazo de Hombro/efectos adversos , Persona de Mediana Edad , Prótesis de Hombro/efectos adversos , Estudios Retrospectivos , Anciano de 80 o más Años , Húmero/cirugía , Articulación del Hombro/cirugía , Adulto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...