Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 309
Filtrar
1.
Biomaterials ; 313: 122754, 2025 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-39197237

RESUMEN

A critical shortage of donor corneas exists worldwide. Hydrogel patches with a biological architecture and functions that simulate those of native corneas have garnered considerable attention. This study introduces a stromal structure replicating corneal patch (SRCP) composed of a decellularized cornea-templated nanotubular skeleton, recombinant human collagen, and methacrylated gelatin, exhibiting a similar ultrastructure and transmittance (above 80 %) to natural cornea. The SRCP is superior to the conventional recombinant human collagen patch in terms of biomechanical properties and resistance to enzymatic degradation. Additionally, SRCP promotes corneal epithelial and stromal cell migration while preventing the trans-differentiation of stromal cells into myofibroblasts. When applied to an ocular surface (37 °C), SRCP releases methacrylated gelatin, which robustly binds SRCP to the corneal stroma after activation by 405 nm light. Compared to gelatin-based photocurable hydrogel, the SRCP better supports the restoration of normal corneal curvature and withstands deformation under an elevated intraocular pressure (100 mmHg). In an in vivo deep anterior-corneal defect model, SRCP facilitated epithelial healing and vision recovery within 2 weeks, maintained graft structural stability, and inhibited stromal scarring at 4 weeks post-operation. The ideal performance of the SRCP makes it a promising humanized corneal equivalent for sutureless clinical applications.


Asunto(s)
Sustancia Propia , Hidrogeles , Humanos , Animales , Hidrogeles/química , Gelatina/química , Cicatrización de Heridas/efectos de los fármacos , Colágeno/química , Conejos , Procedimientos Quirúrgicos sin Sutura/métodos , Córnea
2.
Artículo en Inglés | MEDLINE | ID: mdl-39248114

RESUMEN

The patient is a 35-week-old, 2.6-kg neonate who was diagnosed prenatally with hypoplastic left heart syndrome and a supracardiac variant of total anomalous pulmonary venous connection. We present the technique of stage 1 hybrid palliation combined with repair of total anomalous pulmonary venous connection. Due to the risk of retrograde aortic arch obstruction from the ductal stents, a reverse Blalock-Taussig shunt was performed as well.


Asunto(s)
Procedimiento de Blalock-Taussing , Síndrome del Corazón Izquierdo Hipoplásico , Procedimientos de Norwood , Humanos , Procedimiento de Blalock-Taussing/métodos , Procedimientos de Norwood/métodos , Síndrome del Corazón Izquierdo Hipoplásico/cirugía , Recién Nacido , Procedimientos Quirúrgicos sin Sutura/métodos , Síndrome de Cimitarra/cirugía , Femenino , Masculino
3.
J Refract Surg ; 40(8): e527-e532, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39120019

RESUMEN

PURPOSE: To assess the refractive predictability of the Carlevale sutureless scleral fixation intraocular lens (IOL) (Sole-ko IOL Division) power calculation. METHODS: This retrospective, non-comparative, interventional case series included patients without a capsular support having undergone sutureless scleral fixation IOL implantation in two French hospitals between October 2019 and April 2022. IOL calculation was performed with the Barrett Universal II, Hoffer Q, Holladay 1, and SRK/T formulas with constant optimization to achieve a mean arithmetic prediction error equal to zero. The main outcomes were prediction error (PE) and its standard deviation (SD-PE), the median absolute error (MedAE), the mean absolute error (MAE), and the percentage of eyes with PE within ±0.50, ±1.00 and ±2.00 diopters (D) 6 months after surgery. RESULTS: Thirty eyes of 30 patients were included in the study. The mean age was 66.6 years, the mean axial length was 24.31 mm, and the mean keratometry was 43.07 D. SDPE ranged from 0.73 to 0.87 D depending on the formula. MedAE ranged from 0.38 to 0.61 D, and MAE from 0.52 to 0.68 D. Between 46.7% and 56.7% of eyes were within ±0.50 D, 76.7% and 90.0% were within ±1.00 D, and 96.7% were within ±2.00 D of target equivalent. No statistically significant difference was observed between the four formulas for any outcomes. CONCLUSIONS: This study confirmed that the design of the Carlevale sutureless scleral fixation IOL provides satisfactory refractive results. [J Refract Surg. 2024;40(8):e527-e532.].


Asunto(s)
Implantación de Lentes Intraoculares , Refracción Ocular , Esclerótica , Agudeza Visual , Humanos , Estudios Retrospectivos , Anciano , Esclerótica/cirugía , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares/métodos , Masculino , Femenino , Agudeza Visual/fisiología , Persona de Mediana Edad , Lentes Intraoculares , Seudofaquia/fisiopatología , Anciano de 80 o más Años , Procedimientos Quirúrgicos sin Sutura/métodos , Facoemulsificación , Diseño de Prótesis , Óptica y Fotónica
4.
Braz J Cardiovasc Surg ; 39(4): e20230155, 2024 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-39038084

RESUMEN

OBJECTIVE: This study aimed to compare hemodynamic performances and clinical outcomes of patients with small aortic annulus (SAA) who underwent aortic valve replacement by means of sutureless aortic valve replacement (SUAVR) or transcatheter aortic valve implantation (TAVI). METHODS: From 2015 to 2020, 622 consecutive patients with SAA underwent either SUAVR or TAVI. Through a 1:1 propensity score matching analysis, two homogeneous groups of 146 patients were formed. Primary endpoint: all cause-death at 36 months. Secondary endpoints: incidence of moderate to severe patient-prosthesis mismatch (PPM) and incidence of major adverse cardiovascular and cerebrovascular events (MACCEs). RESULTS: All-cause death at three years was higher in the TAVI group (SUAVR 12.2% vs. TAVI 21.0%, P=0.058). Perioperatively, comparable hemodynamic performances were recorded in terms of indexed effective orifice area (SUAVR 1.12 ± 0.23 cm2/m2 vs. TAVI 1.17 ± 0.28 cm2/m2, P=0.265), mean transvalvular gradients (SUAVR 12.9 ± 5.3 mmHg vs. TAVI 12.2 ± 6.2 mmHg, P=0.332), and moderate-to-severe PPM (SUAVR 4.1% vs. TAVI 8.9%, P=0.096). TAVI group showed a higher cumulative incidence of MACCEs at 36 months (SUAVR 18.1% vs. TAVI 32.6%, P<0.001). Pacemaker implantation (PMI) and perivalvular leak ≥ 2 were significantly higher in TAVI group and identified as independent predictors of mortality (PMI: hazard ratio [HR] 3.05, 95% confidence interval [CI] 1.34-6.94, P=0.008; PPM: HR 2.72, 95% CI 1.25-5.94, P=0.012). CONCLUSION: In patients with SAA, SUAVR and TAVI showed comparable hemodynamic performances. Moreover, all-cause death and incidence of MACCEs at follow-up were significantly higher in TAVI group.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Hemodinámica , Puntaje de Propensión , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Reemplazo de la Válvula Aórtica Transcatéter/mortalidad , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Masculino , Femenino , Hemodinámica/fisiología , Anciano , Anciano de 80 o más Años , Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/mortalidad , Resultado del Tratamiento , Procedimientos Quirúrgicos sin Sutura/métodos , Prótesis Valvulares Cardíacas , Estudios Retrospectivos , Complicaciones Posoperatorias , Implantación de Prótesis de Válvulas Cardíacas/métodos , Factores de Riesgo
5.
Indian J Ophthalmol ; 72(Suppl 4): S658-S663, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38953133

RESUMEN

INTRODUCTION: Cataract surgery constitutes one of the highest volume surgeries performed worldwide approximating 10 million annually, varying from 100 to 6000 per million population. Implantation of scleral fixated intra-ocular lens (SFIOL) is getting popular in managing difficult situations like aphakia, subluxated lens, and dislocated cataracts. OBJECTIVE: This retrospective series evaluated our experience with foldable 3-piece acrylic SFIOL implantation for various challenging surgical scenarios in a tertiary care ophthalmic institute in the southern part of India. RESULTS: The data from the first 150 patients, those operated in our hospital in the aforementioned technique, have been reviewed and analyzed. The mean age of the population was 46.43 years. The most common indication was found to be surgical aphakia (34.66%) followed by traumatic subluxated lens (8.33%). Postoperative BCVA at 3 months improved to 0.255 on the LogMAR scale from preoperative BCVA of 0.795 (P < 0.01). Intraocular pressure was found to stabilize over 3 months follow-up (P = 0.002). The various intraoperative and postoperative complications have been recorded. Ten patients required resurgery out of which eight had postoperative haptic dislocation. A detailed comparison of the role of a surgeon's experience in influencing outcomes has been evaluated. CONCLUSION: The technique offers physiological IOL placement using minimal surgical maneuvers. We strongly recommend this as a technique of choice for the surgical management of complicated scenarios with inadequate capsular bag support.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Esclerótica , Agudeza Visual , Humanos , Estudios Retrospectivos , Esclerótica/cirugía , Masculino , Femenino , Persona de Mediana Edad , Implantación de Lentes Intraoculares/métodos , Adulto , Agudeza Visual/fisiología , Anciano , Procedimientos Quirúrgicos sin Sutura/métodos , Estudios de Seguimiento , Resultado del Tratamiento , Diseño de Prótesis , Adolescente , Adulto Joven , Niño , Técnicas de Sutura
6.
J Am Coll Cardiol ; 84(4): 382-407, 2024 Jul 23.
Artículo en Inglés | MEDLINE | ID: mdl-39019533

RESUMEN

Transcatheter technologies triggered the recent revision of the guidelines that progressively widened the indications for the treatment of aortic stenosis. On the surgical realm, a technology avoiding the need for sutures to anchor the prosthesis to the aortic annulus has been developed with the aim to reduce the duration of cardiopulmonary bypass and simplify the process of valve implantation. In addition to a transcatheter aortic valve replacement (TAVR)-like stent that exerts a radial force, these so-called "rapid deployment valves" or "sutureless valves" for aortic valve replacement also have cuffs to improve sealing and reduce the risk of paravalvular leak. Despite promising, the actual advantage of sutureless valves over traditional surgical procedures (surgical aortic valve replacement) or TAVR is still debated. This review summarizes the current comparative evidence reporting outcomes of "sutureless valves" for aortic valve replacement to TAVR and surgical aortic valve replacement in the treatment of aortic valve stenosis.


Asunto(s)
Prótesis Valvulares Cardíacas , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/métodos , Diseño de Prótesis , Estenosis de la Válvula Aórtica/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Enfermedad de la Válvula Aórtica/cirugía , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos
7.
Sci Rep ; 14(1): 16111, 2024 07 12.
Artículo en Inglés | MEDLINE | ID: mdl-38997328

RESUMEN

This retrospective study aimed to compare the outcomes of modified double-flanged sutureless scleral fixation versus sutured scleral fixation. Medical records of 65 eyes from 65 patients who underwent double-flanged scleral fixation (flange group) or conventional scleral fixation (suture group) between 2021 and 2022 were reviewed. Visual and refractive outcomes, as well as postoperative complications, were compared 1, 2, and 6 months after surgery. We included 31 eyes in the flange group and 34 eyes in the suture group. At 6 months postoperatively, the flange group showed better uncorrected visual acuity (0.251 ± 0.328 vs. 0.418 ± 0.339 logMAR, P = 0.041) and a smaller myopic shift (- 0.74 ± 0.93 vs. - 1.33 ± 1.15 diopter, P = 0.007) compared to the suture group. The flange group did not experience any instances of iris capture, while the suture group had iris capture in 10 eyes (29.4%; P < 0.001). In the flange group, all intraocular lenses remained centered, whereas in the suture group, they were decentered in 8 eyes (23.5%; P = 0.005). The double-flanged technique not only prevented iris capture and decentration of the intraocular lens but also reduced myopic shift by enhancing the stability of the intraocular lens.


Asunto(s)
Esclerótica , Técnicas de Sutura , Agudeza Visual , Humanos , Esclerótica/cirugía , Masculino , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Anciano , Resultado del Tratamiento , Suturas , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Adulto , Complicaciones Posoperatorias/etiología
9.
Int Ophthalmol ; 44(1): 269, 2024 Jun 24.
Artículo en Inglés | MEDLINE | ID: mdl-38914871

RESUMEN

PURPOSE: Evaluation of anterior segment parameters using the Scheimpflug corneal topography 1 year after surgery in patients who underwent sutureless scleral fixation intraocular lens (SFIOL) implantation using the modified Yamane technique and retropupillary iris-claw intraocular lens (RPIOL) implantation. METHODS: A total of 60 eyes from 57 patients who underwent sutureless SFIOL implantation and 57 eyes from 52 patients who underwent RPIOL implantation were included. Anterior chamber depth (ACD), anterior chamber angle (ACA), anterior chamber volume (ACV), anterior-posterior corneal astigmatism, and keratometric values were assessed using the Scheimpflug corneal topography (Pentacam HR, Germany). RESULTS: There was no statistically significant difference in postoperative UCVA and BCVA between the sutureless SFIOL and the RPIOL group (p = 0.236, p = 0.293, respectively). While there was no statistically significant difference in postoperative IOP between the two groups (p = 0.223), a statistically significant decrease in IOP was observed in both groups (p < 0.001). While there was no statistical difference between the sutureless SFIOL group and the RPIOL group in terms of spherical value (p = 0.441) and spherical equivalence (p = 0.237), there was a statistically significant difference in cylindrical value (p < 0.001). While there was a statistical difference in anterior astigmatism (p < 0.001), there was no statistical difference in posterior astigmatism (p = 0.405). There was no statistical difference in terms of ACV, ACD, and ACA between the sutureless SFIOL and the RPIOL group (p = 0.812, p = 0.770, p = 0.401, respectively). CONCLUSION: In this study, although there was a statistical difference in cylindrical value and anterior corneal astigmatism between the sutureless SFIOL and RPIOL groups, vision was not affected. According to this study, sutureless SFIOL and RPIOL are two successful methods in terms of visual acuity, anterior segment, and keratometry outcomes in aphakic patients after phacoemulsification.


Asunto(s)
Topografía de la Córnea , Iris , Implantación de Lentes Intraoculares , Esclerótica , Procedimientos Quirúrgicos sin Sutura , Agudeza Visual , Humanos , Masculino , Femenino , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Persona de Mediana Edad , Anciano , Iris/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Lentes Intraoculares , Estudios Retrospectivos , Segmento Anterior del Ojo/diagnóstico por imagen , Segmento Anterior del Ojo/cirugía , Adulto , Resultado del Tratamiento , Diseño de Prótesis , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Estudios de Seguimiento , Afaquia/cirugía , Afaquia/fisiopatología , Afaquia/diagnóstico
10.
J Plast Reconstr Aesthet Surg ; 95: 288-299, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38945109

RESUMEN

BACKGROUND: Conjunctival prolapse (CP) is an uncommon but challenging condition following maximal levator resection (MLR) and other extensive periorbital procedures. MLR extending beyond the Whitnall's ligament is frequently performed to address severe blepharoptosis with poor levator function (LF). Patients with CP may encounter symptoms such as ocular discomfort, tearing, vision impairment, persistent conjunctival chemosis, lagophthalmos, or exposure keratopathy. Typically, surgical intervention becomes necessary if conservative measures prove to be ineffective; nevertheless, there is no consensus regarding the optimal treatment approach. OBJECTIVES: This study aimed to propose a simple sutureless direct excision method and explore the surgical advancements in CP correction through a systematic review. METHODS: Patients with recurrent CP after MLR who underwent sutureless direct excision of the conjunctiva using loupe magnifiers at a tertiary hospital were included in this study. The clinical evolution and surgical results were recorded. PubMed, MEDLINE, EMBASE, and Web of Science databases were queried following The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) protocol. RESULTS: The comprehensive analysis of 1858 articles identified 88 patients from 24 studies, highlighting that blepharoptosis surgery is predominantly associated with CP (36.6%). Surgically treated CP showed a higher resolution rate compared to those managed conservatively (54.8% vs. 45.2%; p = 0.034). No relapse was observed in patients treated with sutureless direct excision of CP in long-term follow-up. CONCLUSION: We proposed a simple sutureless direct excision technique that offers a straightforward and efficient approach in treating CP, which is particularly suitable for cases requiring excision lengths >16 mm during MLR. Furthermore, stitch removal can be obviated after surgery.


Asunto(s)
Blefaroplastia , Blefaroptosis , Enfermedades de la Conjuntiva , Procedimientos Quirúrgicos sin Sutura , Humanos , Blefaroptosis/cirugía , Blefaroptosis/etiología , Blefaroplastia/métodos , Procedimientos Quirúrgicos sin Sutura/métodos , Enfermedades de la Conjuntiva/cirugía , Enfermedades de la Conjuntiva/etiología , Prolapso , Complicaciones Posoperatorias/cirugía , Complicaciones Posoperatorias/etiología , Conjuntiva/cirugía
12.
J Cardiothorac Surg ; 19(1): 374, 2024 Jun 25.
Artículo en Inglés | MEDLINE | ID: mdl-38918861

RESUMEN

BACKGROUND: Alkaptonuria is a rare congenital metabolic disorder characterized by homogentisic acid accumulation in body cartilage and connective tissues due to a deficient homogentisic acid dioxygenase enzyme. This disorder manifests in various clinical symptoms, including spondyloarthropathy, ocular and dermal pigmentation, genitourinary tract obstruction by ochronosis stones, and cardiovascular system involvement. Cardiac ochronosis is a rare manifestation of alkaptonuria that may present as aortic stenosis, sometimes accompanied by other cardiovascular complications. CASE PRESENTATION: We report an unexpected case of ochronosis diagnosed during cardiac surgery. Due to the fragile, thin, and atheromatous nature of the ascending aorta in patients with ochronosis, we opted for a sutureless aortic valve replacement procedure. This approach appears to be more suitable for patients with ochronosis. CONCLUSIONS: Although cardiac ochronosis is rare, surgeons should remain vigilant and consider the possibility of this condition when examining patients with aortic valve stenosis, paying close attention to the clinical manifestations of alkaptonuria.


Asunto(s)
Estenosis de la Válvula Aórtica , Ocronosis , Humanos , Ocronosis/cirugía , Ocronosis/complicaciones , Estenosis de la Válvula Aórtica/cirugía , Alcaptonuria/complicaciones , Alcaptonuria/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Aórtica/cirugía , Masculino , Procedimientos Quirúrgicos sin Sutura/métodos , Femenino , Anciano
13.
J Cardiothorac Surg ; 19(1): 340, 2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38902742

RESUMEN

BACKGROUND: The aim of this study is to report the preliminary real-word clinical and hemodynamic performance from the MANTRA study in patients undergoing aortic valve replacement with Perceval PLUS sutureless valve. METHODS: MANTRA is an ongoing "umbrella" prospective, multi-center, international post-market study to collect real-life safety and performance data on Corcym devices (Corcym S.r.l, Saluggia, Italy). Clinical and echocardiographic outcomes were collected preoperatively, at discharge and at each follow up. KCCQ-12 and EQ-5D-5L quality of life questionnaires were collected preoperatively and at 30-days. RESULTS: A total of 328 patients underwent aortic valve replacement with Perceval PLUS in 29 International institutions. Patients were enrolled from July 2021 to October 2023 and enrollment is still ongoing. Mean age was 71.9 ± 6.4 years, mean EuroSCORE II was 2.9 ± 3.9. Minimally invasive approach was performed in 44.2% (145/328) of patients; concomitant procedures were done in 40.8% (134/328) of cases. Thirty-day mortality was 1.8% (6/328) and no re-interventions were reported. Pacemaker implant was required in 4.0% (13/328) of the patients. The assessment of the functional status demonstrated marked and stable improvement in NYHA class in most patients at 30-day follow-up, with significant increase of KCCQ-12 summary score (from 58.8 ± 23.0 to 71.8 ± 22.1, p < 0.0001) and EQ-5D-5L VAS score (from 64.5 ± 20.4 to 72.6 ± 17.5, p < 0.0001). Mean pressure gradient decreased from 46.2 ± 17.3 mmHg to 10.1 ± 4.7 mmHg at 30-day follow-up. Low or no incidence of moderate-to-severe paravalvular or central leak was reported. CONCLUSIONS: Preliminary results demonstrate good clinical outcomes and significant improvement of Quality of Life at 30-days, excellent early hemodynamic performance within patient implanted with Perceval PLUS. TRIAL REGISTRATION: The MANTRA study has been registered in ClinicalTrials.gov (NCT05002543, Initial release 26 July 2021).


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Implantación de Prótesis de Válvulas Cardíacas , Prótesis Valvulares Cardíacas , Humanos , Anciano , Masculino , Femenino , Estudios Prospectivos , Válvula Aórtica/cirugía , Implantación de Prótesis de Válvulas Cardíacas/métodos , Resultado del Tratamiento , Estenosis de la Válvula Aórtica/cirugía , Diseño de Prótesis , Procedimientos Quirúrgicos sin Sutura/métodos , Calidad de Vida , Hemodinámica/fisiología , Anciano de 80 o más Años , Persona de Mediana Edad
14.
Int J Med Sci ; 21(8): 1541-1551, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38903929

RESUMEN

Purpose: To compare the clinical outcomes, feasibility, and safety between groups with sutured and sutureless wound closure in congenital ectopia lentis (CEL) patients. Methods: Patients with CEL who received phacoemulsification combined with intrascleral fixation of capsular hook (CH) and implantation of capsular tension ring (CTR) and in-the-bag intraocular lens (IOL) were included in this study. Results: A total of 68 eyes of 34 patients aged 18 years or younger were enrolled in this study. Incisions of 21 patients (34 eyes) did not require sutures while sutures were applied in 21 patients (34 eyes). Postoperative uncorrected distance visual acuity, best corrected distance visual acuity and intraocular pressure measurements were comparable on follow-up visits (P > 0.05). The magnitude of surgically induced astigmatism was significantly greater (P = 0.001) in the suture group (Median: 0.47; IQ: 1.63, 2.97) than in the sutureless group (Median: 0.88; IQ: 0.63, 1.35). No cases of endophthalmitis and retinal detachment were found postoperatively in either group, while suture-related complications were observed in the sutured group, including loose suture with discomfort in 5 (14.71%) eyes, loose suture with mucus infiltration in 3 (8.82%) eyes. In total, 22 sutures (64.71%) of 34 eyes required removal. Conclusions: Sutureless clear corneal incision in CEL patients can achieve satisfactory clinical results comparable to sutured wound closure in terms of the efficacy and safety. Advantages of this approach are the reduced risk of suture-related complications, no need for additional surgery under general anesthesia for suture removal, and less cost.


Asunto(s)
Córnea , Desplazamiento del Cristalino , Implantación de Lentes Intraoculares , Procedimientos Quirúrgicos sin Sutura , Agudeza Visual , Humanos , Femenino , Masculino , Desplazamiento del Cristalino/cirugía , Adolescente , Niño , Implantación de Lentes Intraoculares/métodos , Implantación de Lentes Intraoculares/efectos adversos , Procedimientos Quirúrgicos sin Sutura/métodos , Procedimientos Quirúrgicos sin Sutura/efectos adversos , Córnea/cirugía , Córnea/patología , Facoemulsificación/métodos , Facoemulsificación/efectos adversos , Técnicas de Sutura/efectos adversos , Resultado del Tratamiento , Estudios de Factibilidad , Suturas
15.
Tokai J Exp Clin Med ; 49(2): 89-93, 2024 Jul 20.
Artículo en Inglés | MEDLINE | ID: mdl-38904241

RESUMEN

OBJECTIVE: Two methods are available for intraocular lens (IOL) insertion when the lens capsule is unavailable, including suture and sutureless fixations in which the IOL haptics are fixed in the sclera. The IOL position and refractive error after both procedures were compared. METHODS: Data were retrospectively extracted from patients who underwent IOL insertion at our institution by suture or sutureless fixation (suture fixation: 12 eyes and sutureless fixation: 15 eyes). The postoperative IOL tilt angle and decentration distance were automatically calculated. The difference between the postoperative refractive error and the preoperative expected refractive value was determined and statistically investigated. RESULTS: IOL position, tilt, and decentration were not significantly different between the two groups, but the refractive difference was significantly lower in the sutureless fixation group (P = 0.035). No significant correlation was found between IOL position and refractive difference. CONCLUSIONS: Short-term results reveal that both the suture and sutureless fixation groups performed well, with no significant deviation in IOL tilt and decentration compared to previous reports. However, suture fixation was significantly more prone to refractive differences than sutureless fixation.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Esclerótica , Técnicas de Sutura , Procedimientos Quirúrgicos sin Sutura , Humanos , Implantación de Lentes Intraoculares/métodos , Estudios Retrospectivos , Esclerótica/cirugía , Masculino , Femenino , Anciano , Procedimientos Quirúrgicos sin Sutura/métodos , Persona de Mediana Edad , Errores de Refracción , Anciano de 80 o más Años , Suturas
16.
Zhonghua Yan Ke Za Zhi ; 60(6): 503-510, 2024 Jun 11.
Artículo en Chino | MEDLINE | ID: mdl-38825949

RESUMEN

Objective: To evaluate the efficacy of sutureless intrascleral intraocular lens (IOL) fixation with the modified Yamane technique. Methods: It was a retrospective case series study. Patients undergoing sutureless intrascleral IOL fixation with the modified Yamane technique were included at Beijing Tongren Eye Center, Beijing Tongren Hospital, Capital Medical University from January 2022 to September 2023. Uncorrected visual acuity (UCVA) and best-corrected visual acuity (BCVA), recorded as the logarithm of the minimum angle of resolution (logMAR), were measured before surgery and at 1 day, 3 days, 1 week, 1 month, and 3 months postoperatively. Refractive error and intraocular pressure were also checked. Anterior segment examination with a slit lamp microscope, fundus examination, anterior segment and posterior segment optical coherence tomography were performed. Intraoperative and postoperative ocular complications were documented. Results: A total of 53 patients (53 eyes) were included in this study, comprising 40 males and 13 females, with a median age of 60 (49, 68) years. Among them, the proportion of a history of trauma was 22.6% (12/53). There was 1 eye with intraoperative vitreous hemorrhage (1.9%). All eyes had no obvious hypotony, no obvious inflammation in the anterior chamber, and no pupillary abnormalities at 1 week after surgery. The mean follow-up time was (8.0±3.3) months (range, 3 to 16 months). There was no iris capture, re-dislocation, or haptic exposure of the IOL during the follow-up. The corneal endothelial cell density was (2 236±704) cells/mm2 preoperatively and (1 964±628) cells/mm2 at 1 month, with significant difference (P<0.001). The UCVA (logMAR) was 1.53±0.75 preoperatively, 0.18±0.17 at 1 month, 0.15±0.14 at 3 months, and 0.14±0.13 at the final visit (P<0.001). The UCVA (logMAR) at 1 month was significantly different from that at 3 months and the final visit (both P<0.05). At 1 month, 50.9% (27/53) of the eyes had an UCVA (logMAR)≤0.1, and the rate was 56.6% (30/53) at 3 months. The BCVA (logMAR) was 0.25±0.21, 0.03±0.06, 0.02±0.06, and 0.02±0.06 before surgery, at postoperative1 month, 3 months, and the final visit, respectively (P<0.001). The BCVA (logMAR) at 1 month was not significantly different from that at 3 months and the final visit (both P>0.05). The rate of the eyes with a BCVA (logMAR)≤0 was 81.1% (43/53) at 1 month and 83.0% (44/53) at 3 months. The IOL tilt was (5.18±2.60)° at postoperative 1 month and (5.08±2.48)° at postoperative 3 months, without statistically significant difference (P>0.05). The IOL decentration was (0.35±0.24) mm at postoperative 1 month and (0.32±0.24) mm at postoperative 3 months, without statistically significant difference (P>0.05). Conclusion: Sutureless intrascleral IOL fixation with the modified Yamane technique is simpler and more minimally invasive to achieve a stable and centered IOL implantation with fewer complications and good visual prognosis.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Humanos , Persona de Mediana Edad , Masculino , Femenino , Estudios Retrospectivos , Anciano , Implantación de Lentes Intraoculares/métodos , Esclerótica/cirugía , Agudeza Visual , Procedimientos Quirúrgicos sin Sutura/métodos
17.
J Glaucoma ; 33(9): 686-695, 2024 Sep 01.
Artículo en Inglés | MEDLINE | ID: mdl-38557952

RESUMEN

PRCIS: Deep sclerectomy (DS) with fibrin adhesive can constitute a safe alternative to the classic procedure using sutures, providing nonallergenic, nontoxic, and secure adhesion with no sign of aqueous humor outflow obstruction postoperatively. OBJECTIVE: To evaluate short and medium-term postoperative results of DS with a fibrin sealant. PATIENTS AND METHODS: This prospective, noncomparative, interventional case series involves 12 eyes of 12 patients with uncontrolled open angle glaucoma who underwent DS with Esnoper (Clip or V2000) implant between February 2021 and March 2022. A novel method of wound closure (sclera, Tenon fascia, and conjunctiva) employing fibrin glue was used instead of classic sutures. Surgical outcomes assessed include: intraocular pressure and glaucoma therapy reduction, best-corrected visual acuity changes, and number of complications registered peri and postoperatively. All measurements were performed preoperatively, as well as at 1 day, at 1 and 2 weeks, and at 1, 2, 3, 6, 9, and 12 months after surgery. RESULTS: The mean intraocular pressure decreased from 24.0 ± 9.1 mm Hg to 13.8 ± 6.3 mm Hg at 1 year postoperatively ( P < 0.001). Kaplan-Meier survival analysis revealed complete and qualified success rates of 83.3% and 91.7%. The mean glaucoma therapy decreased from 3.2 ± 1.1 to 0.8 ± 1.3 drugs 12 months after surgery ( P < 0.001). Nd:YAG goniopunture was performed in 2 eyes at 1 and 12 months postoperatively. No significant best-corrected visual acuity changes were registered. Perioperatively, we noted a trabeculo-descemet microperforation in 1 eye, transient hypotony in 5 eyes, and mild hyphema in 2 eyes. CONCLUSIONS: Fibrin adhesive provided an effective closure in sutureless DS in the patients included in our study. This modification of classical DS may simplify the surgical technique, ensure secure wound adaptation, optimize healing, and lower the risk of inflammation and fibrosis postoperatively.


Asunto(s)
Adhesivo de Tejido de Fibrina , Glaucoma de Ángulo Abierto , Presión Intraocular , Esclerótica , Esclerostomía , Procedimientos Quirúrgicos sin Sutura , Adhesivos Tisulares , Agudeza Visual , Humanos , Adhesivo de Tejido de Fibrina/uso terapéutico , Presión Intraocular/fisiología , Masculino , Estudios Prospectivos , Femenino , Esclerostomía/métodos , Glaucoma de Ángulo Abierto/cirugía , Glaucoma de Ángulo Abierto/fisiopatología , Anciano , Agudeza Visual/fisiología , Esclerótica/cirugía , Procedimientos Quirúrgicos sin Sutura/métodos , Adhesivos Tisulares/uso terapéutico , Persona de Mediana Edad , Resultado del Tratamiento , Implantes de Drenaje de Glaucoma , Anciano de 80 o más Años , Estudios de Seguimiento , Tonometría Ocular
18.
Biomaterials ; 308: 122563, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38574456

RESUMEN

A vascular anastomosis is a critical surgical skill that involves connecting blood vessels. Traditional handsewn techniques can be challenging and resource intensive. To address these issues, we have developed a unique sutureless anastomotic device called Vaso-Lock. This intraluminal device connects free vascular ends using anchors to maintain traction and enable a rapid anastomosis. We tested the anastomotic capability of Vaso-Locks in a pig common carotid-internal jugular arteriovenous model. The use of Vaso-Lock allowed us to accomplish this procedure in less than 10 min, in contrast to the approximately 40 min required for a handsewn anastomosis. The Vaso-Lock effectively maintained patency for at least 6 weeks without causing significant tissue damage. Histological analysis revealed that the device was successfully incorporated into the arterial wall, promoting a natural healing process. Additionally, organ evaluations indicated no adverse effects from using the Vaso-Lock. Our findings support the safety and effectiveness of the Vaso-Lock for arteriovenous anastomosis in pigs, with potential applicability for translation to humans. Our novel sutureless device has the potential to advance surgical practice and improve patient outcomes.


Asunto(s)
Anastomosis Quirúrgica , Animales , Porcinos , Procedimientos Quirúrgicos sin Sutura/métodos , Anastomosis Arteriovenosa/cirugía , Grado de Desobstrucción Vascular
19.
J Gastroenterol Hepatol ; 39(7): 1256-1266, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38638082

RESUMEN

Magnetic compression anastomosis (MCA) is a new method that provides sutureless passage construction for tubular organs. Due to the high recurrence rate of conventional endoscopic treatment and the high morbidity and mortality of surgical procedures, the MCA technique shows promise. The aim of this review is to comprehensively examine the literature related to the use of MCA in different gastrointestinal diseases over the past few years, categorizing them according to the anastomotic site and describing in detail the various methods of magnet delivery and the clinical outcomes of MCA. MCA is an innovative technique, and its use represents an advancement in the field of minimally invasive interventions. Comparison studies have shown that the anastomosis formed by MCA is comparable to or better than surgical sutures in terms of general appearance and histology. Although most of the current research has involved animal studies or studies with small populations, the safety and feasibility of MCA have been preliminarily demonstrated. Large prospective studies involving populations are still needed to guarantee the security of MCA. For technologies that have been initially used in clinical settings, effective measures should also be implemented to identify, even prevent, complications. Furthermore, specific commercial magnets must be created and optimized in this emerging area.


Asunto(s)
Anastomosis Quirúrgica , Imanes , Humanos , Anastomosis Quirúrgica/métodos , Endoscopía Gastrointestinal/métodos , Enfermedades Gastrointestinales/cirugía , Animales , Magnetismo , Resultado del Tratamiento , Procedimientos Quirúrgicos sin Sutura/métodos , Presión
20.
BMJ Open Ophthalmol ; 9(1)2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38565231

RESUMEN

BACKGROUND: Pterygium is a common ocular surface disorder that requires surgical intervention for treatment. Conjunctival autografts are preferred over simple excision due to lower recurrence rates. This systematic review and meta-analysis compared the modified sutureless glue-free (MSGF) method with conventional sutures (CS) for conjunctival autograft fixation in primary pterygium surgery. METHODS: A comprehensive search was conducted in MEDLINE, Embase, CENTRAL, Google Scholar and ClinicalTrials.gov for randomised controlled trials (RCTs) comparing MSGF and CS conjunctival autografts. Outcome measures included operation time, recurrence and postoperative complications. Standardised mean difference (SMD) and risk ratio (RR) were used for continuous and dichotomous outcomes, respectively. RESULTS: 11 RCTs involving 833 participants were included. The analysis revealed that MSGF had a significantly shorter operation time compared with CS (SMD -3.704, 95% CI -5.122 to -2.287, p<0.001). CS was associated with a higher risk of foreign body sensation (RR 0.22, 95% CI 0.06 to 0.74, p=0.01). MSGF was associated with a higher risk of graft dehiscence (RR 9.01, 95% CI 2.74 to 29.68, p=0.000) and graft retraction (RR 2.37, 95% CI 1.17 to 4.77, p=0.02). No significant differences were found in recurrence, graft haemorrhage, granuloma, Dellen and conjunctival oedema. CONCLUSION: Using the MSGF technique in conjunctival autograft fixation for pterygium surgery reduces operation time by relying solely on the patient's blood for fixation. However, it increases the risk of graft dehiscence and retraction. However, CS is linked to a higher likelihood of experiencing foreign body sensations. Understanding the learning curve and surgeon familiarity with novel techniques is crucial for optimising patient care and surgical outcomes, while individualised decision-making is necessary considering the advantages and disadvantages of each approach. Further research is warranted to minimise complications and optimise surgical outcomes.


Asunto(s)
Autoinjertos , Conjuntiva , Pterigion , Procedimientos Quirúrgicos sin Sutura , Suturas , Pterigion/cirugía , Humanos , Conjuntiva/trasplante , Procedimientos Quirúrgicos sin Sutura/métodos , Técnicas de Sutura , Trasplante Autólogo/métodos , Complicaciones Posoperatorias/epidemiología , Complicaciones Posoperatorias/etiología , Procedimientos Quirúrgicos Oftalmológicos/métodos , Procedimientos Quirúrgicos Oftalmológicos/efectos adversos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...