Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros












Base de datos
Intervalo de año de publicación
1.
Proc Natl Acad Sci U S A ; 116(33): 16240-16249, 2019 08 13.
Artículo en Inglés | MEDLINE | ID: mdl-31358642

RESUMEN

Rapid and reliable detection of ultralow-abundance nucleic acids and proteins in complex biological media may greatly advance clinical diagnostics and biotechnology development. Currently, nucleic acid tests rely on enzymatic processes for target amplification (e.g., PCR), which have many inherent issues restricting their implementation in diagnostics. On the other hand, there exist no protein amplification techniques, greatly limiting the development of protein-based diagnosis. We report a universal biomolecule enrichment technique termed hierarchical nanofluidic molecular enrichment system (HOLMES) for amplification-free molecular diagnostics using massively paralleled and hierarchically cascaded nanofluidic concentrators. HOLMES achieves billion-fold enrichment of both nucleic acids and proteins within 30 min, which not only overcomes many inherent issues of nucleic acid amplification but also provides unprecedented enrichment performance for protein analysis. HOLMES features the ability to selectively enrich target biomolecules and simultaneously deplete nontargets directly in complex crude samples, thereby enormously enhancing the signal-to-noise ratio of detection. We demonstrate the direct detection of attomolar nucleic acids in urine and serum within 35 min and HIV p24 protein in serum within 60 min. The performance of HOLMES is comparable to that of nucleic acid amplification tests and near million-fold improvement over standard enzyme-linked immunosorbent assay (ELISA) for protein detection, being much simpler and faster in both applications. We additionally measured human cardiac troponin I protein in 9 human plasma samples, and showed excellent agreement with ELISA and detection below the limit of ELISA. HOLMES is in an unparalleled position to unleash the potential of protein-based diagnosis.


Asunto(s)
Proteínas Sanguíneas/aislamiento & purificación , Nanotecnología/tendencias , Ácidos Nucleicos/aislamiento & purificación , Patología Molecular/métodos , Proteínas Sanguíneas/química , Ensayo de Inmunoadsorción Enzimática , Proteína p24 del Núcleo del VIH/sangre , Proteína p24 del Núcleo del VIH/aislamiento & purificación , Proteína p24 del Núcleo del VIH/orina , Humanos , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Amplificación de Ácido Nucleico/métodos , Ácidos Nucleicos/sangre , Ácidos Nucleicos/orina , Troponina I/sangre , Troponina I/aislamiento & purificación
2.
J Clin Lab Anal ; 11(5): 267-86, 1997.
Artículo en Inglés | MEDLINE | ID: mdl-9292394

RESUMEN

Ultrasensitive enzyme immunoassays (immune complex transfer enzyme immunoassays) were developed for antibody IgGs to HIV-1 using recombinant reverse transcriptase (rRT), p17 (rp17), and p24 (rp24) as antigens. Antibody IgGs were reacted with 2,4-dinitrophenyl-recombinant antigens and recombinant antigen-beta-D-galactosidase conjugates, and the immune complexes formed, comprising the three components, were trapped onto polystyrene beads coated with (anti-2,4-dinitrophenyl group) IgG. After washing, the immune complexes were eluted from the polystyrene beads with excess of epsilon N-2,4-dinitrophenyl-L-lysine and were transferred to clean polystyrene beads coated with (antihuman IgG gamma-chain) IgG. beta-D-Galactosidase activity bound to the last polystyrene beads was assayed by fluorometry. By transfer of the immune complexes from one solid phase to another, the nonspecific binding of the beta-D-galactosidase conjugates was minimized and the sensitivity was markedly improved. The immune complex transfer enzyme immunoassays using rRT, rp17, and rp24 as antigens were 300-1,000-fold, 1,000-3,000-fold, and 30-100-fold, respectively, more sensitive than Western blotting for the corresponding antigens and 10-300-fold more sensitive than a conventional ELISA and a gelatin particle agglutination test. For urine (100 microliters), whole saliva (1 microliter), and serum (1 microliter) samples, the sensitivity and specificity of the immune complex transfer enzyme immunoassay using rRT as antigen were both 100%. However, for urine samples in which the specific activities of antibody IgG to RT, p17, and p24 were much lower than those in serum samples probably due to degradation by the kidney, a longer assay of bound beta-D-galactosidase activity or/and a concentration process for urine was required. The use of more than 1 microliter of whole saliva was recommended for reliable diagnosis of the infections, whereas 1 microliter of serum was sufficient for the purpose. The positivity with rRT as antigen could be confirmed by demonstration of antibody IgGs to p17 and p24 in most of the urine, whole saliva, and serum samples. In HIV-1 seroconversion serum panels, antibody IgG to p17 was detected as early as or even earlier than antibodies to HIV-1 by a conventional ELISA or/and a gelation particle agglutination test, whereas antibody IgGs to RT and p24 were detected as early as or later than antibody IgG to p17. Thus the uses of rRT and rp17 as antigens were advantageous over that of the other antigens for randomly collected serum samples probably long after the infection and serum samples at early stages of the infection, respectively. On the basis of these results and other reports, the immune complex transfer enzyme immunoassay was developed for simultaneous detection of p24 antigen and antibody IgGs to RT and p17 in a single assay tube, and the window period (8 weeks, although widely variable), during which diagnosis of HIV-1 infection is not possible due to the absence of detectable antibodies to HIV-1, was shortened by 2 weeks. As a result, the simultaneous detection made possible not only as early diagnosis as that by detection of p24 antigen, but also as reliable diagnosis as that by detection of antibodies to HIV-1. Finally, the immune complex transfer enzyme immunoassay has been recently improved so as to be performed within shorter periods of time (2-3 hr) with higher sensitivity, and testing many samples has become easy.


Asunto(s)
Síndrome de Inmunodeficiencia Adquirida/diagnóstico , Productos del Gen gag/inmunología , Productos del Gen pol/inmunología , Anticuerpos Anti-VIH/análisis , Proteína p24 del Núcleo del VIH/análisis , VIH-1 , Técnicas para Inmunoenzimas , Anticuerpos Anti-VIH/sangre , Anticuerpos Anti-VIH/orina , Proteína p24 del Núcleo del VIH/sangre , Proteína p24 del Núcleo del VIH/orina , Humanos , Inmunoglobulina G/análisis , Inmunoglobulina G/sangre , Inmunoglobulina G/orina , Saliva/virología , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...