Resultados 1 - 20 de 39
Filtrar
1.
Biosens Bioelectron ; 261: 116456, 2024 Oct 01.
Artículo en Inglés | MEDLINE | ID: mdl-38878694

RESUMEN

This study proposes a new efficient wireless biosensor based on magnetoelastic waves for antibody detection in human plasma, aiming at the serological diagnosis of COVID-19. The biosensor underwent functionalization with the N antigen - nucleocapsid phosphoprotein of the SARS-CoV-2 virus. Validation analyses by sodium dodecyl-sulfate polyacrylamide gel electrophoresis (SDS-PAGE), Western blotting (WB), atomic force microscopy (AFM), scanning electron microscopy (SEM), energy-dispersive X-ray (EDX) microanalysis and micro-Raman spectroscopy confirmed the selectivity and effective surface functionalization of the biosensor. The research successfully obtained, expressed and purified the recombinant antigen, while plasma samples from COVID-19 positive and negative patients were applied to test the performance of the biosensor. A performance comparison with the enzyme-linked immunosorbent assays (ELISA) method revealed equivalent diagnostic capacity. These results indicate the robustness of the biosensor in reliably differentiating between positive and negative samples, highlighting its potential as an efficient and low-cost tool for the serological diagnosis of COVID-19. In addition to being fast to execute and having the potential for automation in large-scale diagnostic studies, the biosensor fills a significant gap in existing SARS-CoV-2 detection approaches.


Asunto(s)
Anticuerpos Antivirales , Técnicas Biosensibles , Prueba Serológica para COVID-19 , COVID-19 , SARS-CoV-2 , Humanos , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Anticuerpos Antivirales/sangre , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , COVID-19/diagnóstico , COVID-19/sangre , Prueba Serológica para COVID-19/métodos , Prueba Serológica para COVID-19/instrumentación , Proteínas de la Nucleocápside de Coronavirus/inmunología , Fosfoproteínas/inmunología , Fosfoproteínas/sangre , Fosfoproteínas/química , Ensayo de Inmunoadsorción Enzimática
3.
Bioanalysis ; 14(6): 325-340, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35234530

RESUMEN

Background: With the spread of COVID-19, anti-SARS-CoV-2 antibody tests have been utilized. Herein we evaluated the analytical performance of anti-SARS-CoV-2 antibody test kits using a new reference standard prepared from COVID-19 patient sera. Methods: Fifty-seven kits in total (16 immunochromatography types, 11 ELISA types and 30 types for automated analyzers) were examined. By measuring serially diluted reference standards, the maximum dilution factor showing a positive result and its precision were investigated. Results: The measured cut-off titers varied largely depending on the antibody kit; however, the variability was small, with the titers obtained by each kit being within twofold in most cases. Conclusion: The current results suggest that a suitable kit should be selected depending on the intended purpose.


Asunto(s)
Prueba Serológica para COVID-19/métodos , Juego de Reactivos para Diagnóstico , Anticuerpos Antivirales/sangre , Automatización de Laboratorios , Prueba Serológica para COVID-19/instrumentación , Prueba Serológica para COVID-19/normas , Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/métodos , Humanos , Inmunoglobulina G/sangre , Japón , SARS-CoV-2/inmunología
4.
Microbiol Spectr ; 10(1): e0161421, 2022 02 23.
Artículo en Inglés | MEDLINE | ID: mdl-35171037

RESUMEN

The antigen-based rapid diagnostic test (Ag-RDT) using saliva specimens is fast, noninvasive, and suitable for SARS-CoV-2 self-testing, unlike nasopharyngeal swab (NPS) testing. We evaluated a novel Beanguard gargle (BG)-based virus collection method that can be applied to Ag-RDT as an alternative to the current RT-PCR with an NPS for early diagnosis of COVID-19. This clinical trial comprised 102 COVID-19-positive patients hospitalized after a governmental screening process and 100 healthy individuals. Paired NPS and BG-based saliva specimens from COVID-19 patients and healthy individuals were analyzed using NPS-RT-PCR, BG-RT-PCR, and BG-Ag-RDTs, whose diagnostic performance for detecting SARS-CoV-2 was compared. BG-Ag-RDTs showed high sensitivity (97.8%) and specificity (100%) in 45 patients within 6 days of illness and detected all cases of SARS-CoV-2 Alpha and Delta variants. In 11 asymptomatic active COVID-19 cases, both BG-Ag-RDTs and BG-RT-PCR showed sensitivities and specificities of 100%. Sensitivities of BG-Ag-RDT and BG-RT-PCR toward salivary viral detection were highly concordant, with no discrimination between symptomatic (97.0%), asymptomatic (100%), or SARS-CoV-2 variant (100%) cases. The intermolecular interactions between SARS-CoV-2 spike proteins and truncated canavalin, an active ingredient from the bean extract (BE), were observed in terms of physicochemical properties. The detachment of the SARS-CoV-2 receptor-binding domain from hACE2 increased as the BE concentration increased, allowing the release of the virus from hACE2 for early diagnosis. Using BG-based saliva specimens remarkably enhances the Ag-RDT diagnostic performance as an alternative to NPS and enables noninvasive, rapid, and accurate COVID-19 self-testing and mass screening, supporting efficient COVID-19 management. IMPORTANCE An Ag-RDT is less likely to be accepted as an initial test method for early diagnosis owing to its low sensitivity. However, our self-collection method, Ag-RDT using BG-based saliva specimens, showed significantly enhanced detection sensitivity and specificity toward SARS-CoV-2 including the Alpha and Delta variants in all patients tested within 6 days of illness. The method represents an attractive alternative to nasopharyngeal swabs for the early diagnosis of symptomatic and asymptomatic COVID-19 cases. The evidence suggests that the method could have a potential for mass screening and monitoring of COVID-19 cases.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Saliva/virología , Adulto , Anciano , Anciano de 80 o más Años , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19 , Prueba Serológica para COVID-19/instrumentación , Femenino , Humanos , Masculino , Persona de Mediana Edad , Nasofaringe/virología , República de Corea , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Adulto Joven
5.
J Nanobiotechnology ; 20(1): 6, 2022 Jan 04.
Artículo en Inglés | MEDLINE | ID: mdl-34983543

RESUMEN

BACKGROUND: Gold nanoparticles (AuNPs) have been widely used in local surface plasmon resonance (LSPR) immunoassays for biomolecule sensing, which is primarily based on two conventional methods: absorption spectra analysis and colorimetry. The low figure of merit (FoM) of the LSPR and high-concentration AuNP requirement restrict their limit of detection (LOD), which is approximately ng to µg mL-1 in antibody detection if there is no other signal or analyte amplification. Improvements in sensitivity have been slow in recent for a long time, and pushing the boundary of the current LOD is a great challenge of current LSPR immunoassays in biosensing. RESULTS: In this work, we developed spectral image contrast-based flow digital nanoplasmon-metry (Flow DiNM) to push the LOD boundary. Comparing the scattering image brightness of AuNPs in two neighboring wavelength bands near the LSPR peak, the peak shift signal is strongly amplified and quickly detected. Introducing digital analysis, the Flow DiNM provides an ultrahigh signal-to-noise ratio and has a lower sample volume requirement. Compared to the conventional analog LSPR immunoassay, Flow DiNM for anti-BSA detection in pure samples has an LOD as low as 1 pg mL-1 within only a 15-min detection time and 500 µL sample volume. Antibody assays against spike proteins of SARS-CoV-2 in artificial saliva that contained various proteins were also conducted to validate the detection of Flow DiNM in complicated samples. Flow DiNM shows significant discrimination in detection with an LOD of 10 pg mL-1 and a broad dynamic detection range of five orders of magnitude. CONCLUSION: Together with the quick readout time and simple operation, this work clearly demonstrated the high sensitivity and selectivity of the developed Flow DiNM in rapid antibody detection. Spectral image contrast and digital analysis further provide a new generation of LSPR immunoassay with AuNPs.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Resonancia por Plasmón de Superficie/métodos , Anticuerpos Antivirales/inmunología , COVID-19/inmunología , Prueba Serológica para COVID-19/instrumentación , Diseño de Equipo , Oro/química , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Nanopartículas del Metal/química , SARS-CoV-2/inmunología , Saliva/virología , Glicoproteína de la Espiga del Coronavirus/inmunología , Resonancia por Plasmón de Superficie/instrumentación
6.
Anal Bioanal Chem ; 414(8): 2607-2618, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35091761

RESUMEN

The lateral flow assay (LFA) is one of the most popular technologies on the point-of-care diagnostics market due to its low cost and ease of use, with applications ranging from pregnancy to environmental toxins to infectious disease. While the use of these tests is relatively straightforward, significant development time and effort are required to create tests that are both sensitive and specific. Workflows to guide the LFA development process exist but moving from target selection to an LFA that is ready for field testing can be labor intensive, resource heavy, and time consuming. To reduce the cost and the duration of the LFA development process, we introduce a novel development platform centered on the flexibility, speed, and throughput of an automated robotic liquid handling system. The system comprises LFA-specific hardware and software that enable large optimization experiments with discrete and continuous variables such as antibody pair selection or reagent concentration. Initial validation of the platform was demonstrated during development of a malaria LFA but was readily expanded to encompass development of SARS-CoV-2 and Mycobacterium tuberculosis LFAs. The validity of the platform, where optimization experiments are run directly on LFAs rather than in solution, was based on a direct comparison between the robotic system and a more traditional ELISA-like method. By minimizing hands-on time, maximizing experiment size, and enabling improved reproducibility, the robotic system improved the quality and quantity of LFA assay development efforts.


Asunto(s)
COVID-19/diagnóstico , Inmunoensayo/instrumentación , Malaria/diagnóstico , Pruebas en el Punto de Atención , Tuberculosis/diagnóstico , Prueba Serológica para COVID-19/economía , Prueba Serológica para COVID-19/instrumentación , Diseño de Equipo , Humanos , Inmunoensayo/economía , Mycobacterium tuberculosis/aislamiento & purificación , Plasmodium/aislamiento & purificación , Pruebas en el Punto de Atención/economía , Reproducibilidad de los Resultados , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad , Factores de Tiempo
8.
J Med Virol ; 94(4): 1633-1640, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-34904253

RESUMEN

The coronavirus disease 2019 (COVID-19) is outbreaking all over the world. To help fight this disease, it is necessary to establish an effective and rapid detection method. The nucleocapsid (N) protein of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is involved in viral replication, assembly, and immune regulation and plays an important role in the viral life cycle. Moreover, the N protein also could be a diagnostic factor and potential drug target. Therefore, by synthesizing the N gene sequence of SARS-CoV-2, constructing the pET-28a (+)-N recombinant plasmid, we expressed the N protein in Escherichia coli and obtained 15 monoclonal antibody (mAbs) against SARS-CoV-2-N protein by the hybridomas and ascites, then an immunochromatographic test strip method detecting N antigen was established. In this study, we obtained 14 high-titer and high-specificity monoclonal antibodies, and the test strips exclusively react with the SARS-CoV-2-N protein and no cross-reactivity with other coronavirus and also recognize the recombinant N protein of Delta (B.1.617.2) variant. These mAbs can be used for the early and rapid diagnosis of SARS-CoV-2 infection through serological antigen.


Asunto(s)
Anticuerpos Monoclonales/inmunología , Prueba Serológica para COVID-19/instrumentación , Proteínas de la Nucleocápside de Coronavirus/inmunología , SARS-CoV-2/aislamiento & purificación , Animales , COVID-19/sangre , COVID-19/diagnóstico , Prueba Serológica para COVID-19/métodos , Proteínas de la Nucleocápside de Coronavirus/sangre , Proteínas de la Nucleocápside de Coronavirus/genética , Humanos , Inmunoensayo , Ratones , Mutación , Fosfoproteínas/sangre , Fosfoproteínas/genética , Fosfoproteínas/inmunología , Proteínas Recombinantes/genética , Proteínas Recombinantes/inmunología , SARS-CoV-2/genética , SARS-CoV-2/inmunología , Sensibilidad y Especificidad
9.
Bioengineered ; 13(1): 876-883, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34968171

RESUMEN

This research has developed a method for rapid detection of SARS-CoV-2 N protein on a paper-based microfluidic chip. The chitosan-glutaraldehyde cross-linking method is used to fix the coated antibody, and the sandwich enzyme-linked immunosorbent method is used to achieve the specific detection of the target antigen. The system studied the influence of coating antibody concentration and enzyme-labeled antibody concentration on target antigen detection. According to the average gray value measured under different N protein concentrations, the standard curve of the method was established and the sensitivity was tested, and its linear regression was obtained. The equation is y = 9.8286x+137.6, R2 = 0.9772 > 0.90, which shows a high degree of fit. When the concentration of coating antibody and enzyme-labeled antibody were 1 µg/mL and 2 µg/mL, P > 0.05, the difference was not statistically significant, so the lower concentration of 1 µg/mL was chosen as the coating antibody concentration. The results show that the minimum concentration of N protein that can be detected by this method is 8 µg/mL, and the minimum concentration of coating antibody and enzyme-labeled antibody is 1 µg/mL, which has the characteristics of high sensitivity and good repeatability.


Asunto(s)
Antígenos Virales/análisis , Prueba Serológica para COVID-19/instrumentación , Proteínas de la Nucleocápside de Coronavirus/análisis , Proteínas de la Nucleocápside de Coronavirus/inmunología , Dispositivos Laboratorio en un Chip , SARS-CoV-2/química , SARS-CoV-2/inmunología , Anticuerpos Antivirales/inmunología , Ingeniería Biomédica , COVID-19/diagnóstico , COVID-19/inmunología , COVID-19/virología , Prueba Serológica para COVID-19/métodos , Prueba Serológica para COVID-19/normas , Proteínas de la Nucleocápside de Coronavirus/normas , Ensayo de Inmunoadsorción Enzimática/instrumentación , Ensayo de Inmunoadsorción Enzimática/métodos , Ensayo de Inmunoadsorción Enzimática/normas , Humanos , Dispositivos Laboratorio en un Chip/normas , Dispositivos Laboratorio en un Chip/estadística & datos numéricos , Procedimientos Analíticos en Microchip/métodos , Procedimientos Analíticos en Microchip/normas , Procedimientos Analíticos en Microchip/estadística & datos numéricos , Papel , Fosfoproteínas/análisis , Fosfoproteínas/inmunología , Fosfoproteínas/normas
10.
Anal Bioanal Chem ; 414(3): 1313-1322, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-34741650

RESUMEN

Among the deadliest pandemics in history, coronavirus disease 2019 (COVID-19) has wreaked havoc on human lives, economies and public health systems worldwide. To temper its effects, diagnostic methods that are simple, rapid, inexpensive, accurate, selective and sensitive continue to be necessary. In our study, we developed an electrochemical biosensing platform based on gold clusters, mercaptoethanol, the spike protein of severe acute respiratory syndrome-coronavirus-2 (SARS-CoV-2) antigen and bovine serum albumin-modified glassy carbon electrode able to detect the SARS-CoV-2 spike antibody. Moreover, during the detection of the SARS-CoV-2 spike antibody in spiked-real samples, the anodic signal of the produced biosensor at 0.85 V decreased as the amount of the SARS-CoV-2 spike antibody increased. Meanwhile, the recovery and relative standard deviation values for saliva and oropharyngeal swab samples were 97.73% and 3.35% and 102.43% and 4.63%, respectively. In 35 min, the biosensing platform could detect 0.03 fg/mL of the SARS-CoV-2 spike antibody in synthetic media and spiked-saliva or -oropharyngeal swab samples. The method thus issues a linear response to the SARS-CoV-2 spike antibody from 0.1 fg/mL to 10 pg/mL. The cross-reactivity studies with spike antigens of Middle East respiratory syndrome-coronavirus and influenza A and the antigen of pneumonia confirmed the excellent selectivity of the proposed method. The developed method was compared with the lateral flow immunoassay method in terms of sensitivity and it was found to be approximately 109 times more sensitive. Biosensing mechanism of the platform to the SARS-CoV-2 spike antibody.


Asunto(s)
Anticuerpos Antivirales/análisis , Prueba Serológica para COVID-19/instrumentación , COVID-19/diagnóstico , SARS-CoV-2/aislamiento & purificación , Glicoproteína de la Espiga del Coronavirus/análisis , Anticuerpos Antivirales/inmunología , Técnicas Biosensibles/instrumentación , COVID-19/inmunología , Técnicas Electroquímicas/instrumentación , Diseño de Equipo , Humanos , Enlace de Hidrógeno , Modelos Moleculares , SARS-CoV-2/inmunología , Saliva/virología , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunología
11.
J Clin Lab Anal ; 35(12): e24091, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34741352

RESUMEN

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) is a highly infectious and concealed virus that causes pneumonia, severe acute respiratory syndrome, and even death. Although the epidemic has been controlled since the development of vaccines and quarantine measures, many people are still infected, particularly in third-world countries. Several methods have been developed for detection of SARS-CoV-2, but owing to its price and efficiency, the immune strip could be a better method for the third-world countries. METHODS: In this study, two antibodies were linked to latex microspheres, using 1-(3-dimethylaminopropyl)-3-ethylcarbodiimide hydrochloride and N-hydroxysuccinimide, as the bridge to decrease the cost further and improve the detection performance. The specificity of the lateral flow immunoassay strip (LFIA) was tested by several common viruses and respiratory bacterial infections. Besides, the reproducibility and stability of the LFIAs were tested on the same batch of test strips. Under optimal conditions, the sensitivity of LFIA was determined by testing different dilutions of the positive specimens. RESULTS: The proposed LFIAs were highly specific, and the limit of detection was as low as 25 ng/mL for SARS-CoV-2 antigens. The clinical applicability was evaluated with 659 samples (230 positive and 429 negative samples) by using both LFIA and rRT-PCR. Youden's index (J) was used to assess the performance of these diagnostic tests. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. The sensitivity and specificity were 98.22% and 97.93%, respectively, and J is 0.9615. In addition, the consistency of our proposed LFIA was analyzed using Cohen's kappa coefficient (κ = 0.9620). CONCLUSION: We found disease stage, age, gender, and clinical manifestations have only a slight influence on the diagnosis. Therefore, the lateral flow immunoassay SARS-CoV-2 antigen test strip is suitable for point-of-care detection and provides a great application for SARS-CoV-2 epidemic control in the third-world countries.


Asunto(s)
Antígenos Virales/análisis , Prueba Serológica para COVID-19/métodos , Inmunoensayo/métodos , Prueba Serológica para COVID-19/instrumentación , Carbodiimidas/química , Humanos , Inmunoensayo/instrumentación , Látex/química , Metilaminas/química , Microscopía Electrónica de Rastreo , Microesferas , Sistemas de Atención de Punto , Reproducibilidad de los Resultados , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , SARS-CoV-2/inmunología , Sensibilidad y Especificidad , Succinimidas/química
12.
Sci Rep ; 11(1): 20143, 2021 10 11.
Artículo en Inglés | MEDLINE | ID: mdl-34635788

RESUMEN

Rapid, high-throughput diagnostic tests are essential to decelerate the spread of the novel coronavirus disease 2019 (COVID-19) pandemic. While RT-PCR tests performed in centralized laboratories remain the gold standard, rapid point-of-care antigen tests might provide faster results. However, they are associated with markedly reduced sensitivity. Bedside breath gas analysis of volatile organic compounds detected by ion mobility spectrometry (IMS) may enable a quick and sensitive point-of-care testing alternative. In this proof-of-concept study, we investigated whether gas analysis by IMS can discriminate severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from other respiratory viruses in an experimental set-up. Repeated gas analyses of air samples collected from the headspace of virus-infected in vitro cultures were performed for 5 days. A three-step decision tree using the intensities of four spectrometry peaks correlating to unidentified volatile organic compounds allowed the correct classification of SARS-CoV-2, human coronavirus-NL63, and influenza A virus H1N1 without misassignment when the calculation was performed with data 3 days post infection. The forward selection assignment model allowed the identification of SARS-CoV-2 with high sensitivity and specificity, with only one of 231 measurements (0.43%) being misclassified. Thus, volatile organic compound analysis by IMS allows highly accurate differentiation of SARS-CoV-2 from other respiratory viruses in an experimental set-up, supporting further research and evaluation in clinical studies.


Asunto(s)
Antígenos Virales/aislamiento & purificación , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Pruebas en el Punto de Atención , SARS-CoV-2/aislamiento & purificación , Animales , COVID-19/inmunología , COVID-19/virología , Prueba Serológica para COVID-19/instrumentación , Chlorocebus aethiops , Coronavirus Humano NL63/inmunología , Coronavirus Humano NL63/aislamiento & purificación , Diagnóstico Diferencial , Ensayos Analíticos de Alto Rendimiento/instrumentación , Ensayos Analíticos de Alto Rendimiento/métodos , Humanos , Subtipo H1N1 del Virus de la Influenza A/inmunología , Subtipo H1N1 del Virus de la Influenza A/aislamiento & purificación , Espectrometría de Movilidad Iónica , Prueba de Estudio Conceptual , SARS-CoV-2/inmunología , Células Vero
13.
PLoS One ; 16(9): e0256566, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34469472

RESUMEN

BACKGROUND: Adequate testing is critically important for control of the SARS-CoV-2 pandemic. Antibody testing is an option for case management and epidemiologic studies, with high specificity and variable sensitivity. However, characteristics of local populations may affect performance of these tests. For this reason, the National Institute of Health (INS) and regulatory agencies in Colombia require verification of diagnostic accuracy of tests introduced to the Colombian market. METHODS: We conducted a validation study of the Abbott SARS-CoV-2 test for qualitative detection of IgG using the Abbott Architect i2000SR. Participants and retrospective samples were included from patients with suspected SARS-CoV-2 infection, age ≥18 years, and ≥8 days elapsed since initiation of symptoms. Pre-pandemic plasma samples (taken before October 2019) were used as controls. We estimated the sensitivity, specificity and agreement (kappa) of the Abbott IgG test compared to the gold standard (RT-PCR). RESULTS: The overall sensitivity was 83.1% (95% CI: 75.4-100). Sensitivity among patients with ≥14 days since the start of symptoms was 85.7%, reaching 88% in samples collected from patients with COVID-19 symptoms onset >60 days. Specificity was 100% and the kappa index of agreement was 0.804 (95% CI: 0.642-0.965). CONCLUSIONS: Our findings show high sensitivity and specificity of the Abbott IgG test in a Colombian population, which meet the criteria set by the Colombian INS to aid in the diagnosis of COVID-19. Data from our patient groups also suggest that IgG response is detectable in a high proportion of individuals (88.1%) during the first two months following onset of symptoms.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/instrumentación , COVID-19/sangre , Inmunoglobulina G/sangre , Pandemias , SARS-CoV-2/metabolismo , Adulto , Anciano , COVID-19/epidemiología , Colombia/epidemiología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Estudios Retrospectivos , Sensibilidad y Especificidad
14.
Viruses ; 13(8)2021 07 30.
Artículo en Inglés | MEDLINE | ID: mdl-34452373

RESUMEN

The development of rapid serological detection methods re urgently needed for determination of neutralizing antibodies in sera. In this study, four rapid methods (ACE2-RBD inhibition assay, S1-IgG detection, RBD-IgG detection, and N-IgG detection) were established and evaluated based on chemiluminescence technology. For the first time, a broadly neutralizing antibody with high affinity was used as a standard for the quantitative detection of SARS-CoV-2 specific neutralizing antibodies in human sera. Sera from COVID-19 convalescent patients (N = 119), vaccinated donors (N = 86), and healthy donors (N = 299) confirmed by microneutralization test (MNT) were used to evaluate the above methods. The result showed that the ACE2-RBD inhibition assay calculated with either ACE2-RBD binding inhibition percentage rate or ACE2-RBD inhibiting antibody concentration were strongly correlated with MNT (r ≥ 0.78, p < 0.0001) and also highly consistent with MNT (Kappa Value ≥ 0.94, p < 0.01). There was also a strong correlation between the two evaluation indices (r ≥ 0.99, p < 0.0001). Meanwhile, S1-IgG and RBD-IgG quantitative detection were also significantly correlated with MNT (r ≥ 0.73, p < 0.0001), and both methods were highly correlated with each other (r ≥ 0.95, p < 0.0001). However, the concentration of N-IgG antibodies showed a lower correlation with the MNT results (r < 0.49, p < 0.0001). The diagnostic assays presented here could be used for the evaluation of SARS-CoV-2 vaccine immunization effect and serological diagnosis of COVID-19 patients, and could also have guiding significance for establishing other rapid serological methods to surrogate neutralization tests for SARS-CoV-2.


Asunto(s)
Anticuerpos Neutralizantes/sangre , Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , Vacunas contra la COVID-19/inmunología , COVID-19/virología , Inmunoensayo/métodos , Mediciones Luminiscentes/métodos , SARS-CoV-2/inmunología , COVID-19/sangre , COVID-19/inmunología , COVID-19/prevención & control , Prueba Serológica para COVID-19/instrumentación , Vacunas contra la COVID-19/administración & dosificación , Humanos , SARS-CoV-2/genética , Vacunación
15.
J Clin Lab Anal ; 35(9): e23921, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34369009

RESUMEN

BACKGROUND: SARS-CoV-2 pandemic is currently ongoing, meanwhile vaccinations are rapidly underway in some countries. The quantitative immunoassays detecting antibodies against spike antigen of SARS-CoV-2 have been developed based on the findings that they have a better correlation with the neutralizing antibody. METHODS: The performances of the Abbott Architect SARS-CoV-2 IgG II Quant, DiaSorin LIAISON SARS-CoV-2 TrimericS IgG, and Roche Elecsys anti-SARS-CoV-2 S were evaluated on 173 sera from 126 SARS-CoV-2 patients and 151 pre-pandemic sera. Their correlations with GenScript cPass SARS-CoV-2 Neutralization Antibody Detection Kit were also analyzed on 173 sera from 126 SARS-CoV-2 patients. RESULTS: Architect SARS-CoV-2 IgG II Quant and Elecsys anti-SARS-CoV-2 S showed the highest overall sensitivity (96.0%), followed by LIAISON SARS-CoV-2 TrimericS IgG (93.6%). The specificities of Elecsys anti-SARS-CoV-2 S and LIAISON SARS-CoV-2 TrimericS IgG were 100.0%, followed by Architect SARS-CoV-2 IgG II Quant (99.3%). Regarding the correlation with cPass neutralization antibody assay, LIAISON SARS-CoV-2 TrimericS IgG showed the best correlation (Spearman rho = 0.88), followed by Architect SARS-CoV-2 IgG II Quant and Elecsys anti-SARS-CoV-2 S (all rho = 0.87). CONCLUSIONS: The three automated quantitative immunoassays showed good diagnostic performance and strong correlations with neutralization antibodies. These assays will be useful in diagnostic assistance, evaluating the response to vaccination, and the assessment of herd immunity in the future.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/virología , Inmunoensayo/métodos , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/inmunología , Anticuerpos Neutralizantes/sangre , Prueba Serológica para COVID-19/instrumentación , Humanos , Inmunoglobulina G/sangre , Pruebas de Neutralización , Curva ROC , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Pruebas Serológicas
16.
Nat Commun ; 12(1): 4586, 2021 07 28.
Artículo en Inglés | MEDLINE | ID: mdl-34321486

RESUMEN

Heterogeneous immunoassays such as ELISA have become indispensable in modern bioanalysis, yet translation into point-of-care assays is hindered by their dependence on external calibration and multiple washing and incubation steps. Here, we introduce RAPPID (Ratiometric Plug-and-Play Immunodiagnostics), a mix-and-measure homogeneous immunoassay platform that combines highly specific antibody-based detection with a ratiometric bioluminescent readout. The concept entails analyte-induced complementation of split NanoLuc luciferase fragments, photoconjugated to an antibody sandwich pair via protein G adapters. Introduction of a calibrator luciferase provides a robust ratiometric signal that allows direct in-sample calibration and quantitative measurements in complex media such as blood plasma. We developed RAPPID sensors that allow low-picomolar detection of several protein biomarkers, anti-drug antibodies, therapeutic antibodies, and both SARS-CoV-2 spike protein and anti-SARS-CoV-2 antibodies. With its easy-to-implement standardized workflow, RAPPID provides an attractive, fast, and low-cost alternative to traditional immunoassays, in an academic setting, in clinical laboratories, and for point-of-care applications.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Inmunoensayo/normas , Mediciones Luminiscentes/normas , SARS-CoV-2/inmunología , Glicoproteína de la Espiga del Coronavirus/sangre , COVID-19/inmunología , COVID-19/virología , Prueba Serológica para COVID-19/instrumentación , Calibración , Proteínas de Unión al GTP/química , Genes Reporteros , Humanos , Inmunoconjugados/química , Límite de Detección , Luciferasas/genética , Luciferasas/metabolismo , Pruebas en el Punto de Atención , SARS-CoV-2/genética
17.
J Immunol Methods ; 496: 113096, 2021 09.
Artículo en Inglés | MEDLINE | ID: mdl-34242653

RESUMEN

Serology or antibody tests for COVID-19 are designed to detect antibodies (mainly Immunoglobulin M (IgM) and Immunoglobulin G (IgG) produced in response to Severe Acute Respiratory Syndrome Coronavirus 2 (SARS CoV-2) infection. In this study, 30 lateral flow immunoassays were tested using serum or plasma from patients with confirmed SARS CoV-2 infection. Negative serological controls were accessed from a well-characterised bank of sera which were stored prior to February 2020. Operational characteristics and ease of use of the assays are reported. 4/30 (13%) of kits (Zheihang Orient Gene COVID-19 IgG/IgM, Genrui Novel Coronavirus (2019-nCoV) IgG/IgM, Biosynex COVID-19 BSS IgG/IgM, Boson Biotech 2019-nCoV IgG/IgM) were recommended for SAHPRA approval based on kit sensitivity. Of these, only the Orientgene was recommended by SAHPRA in August 2020 for use within the approved national testing algorithm while the remaining three received limited authorization for evaluation. All kits evaluated work on the same basic principle of immunochromatography with minor differences noted in the shape and colour of cartridges, the amount of specimen volume required and the test duration. Performance of the lateral flow tests were similar to sensitivities and specificities reported in other studies. The cassettes of the majority of kits evaluated (90%) detected both IgG and IgM. Only 23% of kits evaluated contained all consumables required for point-of-care testing. The study highlights the need for thorough investigation of kits prior to implementation.


Asunto(s)
Anticuerpos Antivirales/aislamiento & purificación , Prueba Serológica para COVID-19/instrumentación , COVID-19/diagnóstico , Inmunoensayo/instrumentación , Juego de Reactivos para Diagnóstico/estadística & datos numéricos , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/inmunología , COVID-19/virología , Prueba de Ácido Nucleico para COVID-19/estadística & datos numéricos , Prueba Serológica para COVID-19/estadística & datos numéricos , Humanos , Inmunoensayo/estadística & datos numéricos , Inmunoglobulina G/sangre , Inmunoglobulina G/inmunología , Inmunoglobulina G/aislamiento & purificación , Inmunoglobulina M/sangre , Inmunoglobulina M/inmunología , Inmunoglobulina M/aislamiento & purificación , Pruebas en el Punto de Atención/estadística & datos numéricos , ARN Viral/sangre , ARN Viral/aislamiento & purificación , SARS-CoV-2/genética , SARS-CoV-2/inmunología , SARS-CoV-2/aislamiento & purificación , Sensibilidad y Especificidad
18.
Sci Adv ; 7(26)2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34172447

RESUMEN

Highly sensitive, specific, and point-of-care (POC) serological assays are an essential tool to manage coronavirus disease 2019 (COVID-19). Here, we report on a microfluidic POC test that can profile the antibody response against multiple severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) antigens-spike S1 (S1), nucleocapsid (N), and the receptor binding domain (RBD)-simultaneously from 60 µl of blood, plasma, or serum. We assessed the levels of antibodies in plasma samples from 31 individuals (with longitudinal sampling) with severe COVID-19, 41 healthy individuals, and 18 individuals with seasonal coronavirus infections. This POC assay achieved high sensitivity and specificity, tracked seroconversion, and showed good concordance with a live virus microneutralization assay. We can also detect a prognostic biomarker of severity, IP-10 (interferon-γ-induced protein 10), on the same chip. Because our test requires minimal user intervention and is read by a handheld detector, it can be globally deployed to combat COVID-19.


Asunto(s)
Prueba Serológica para COVID-19/métodos , COVID-19/diagnóstico , Pruebas en el Punto de Atención , SARS-CoV-2/inmunología , Anticuerpos Antivirales/sangre , Anticuerpos Antivirales/inmunología , COVID-19/sangre , COVID-19/virología , Prueba Serológica para COVID-19/instrumentación , Humanos , Reproducibilidad de los Resultados , SARS-CoV-2/metabolismo , SARS-CoV-2/fisiología , Sensibilidad y Especificidad , Glicoproteína de la Espiga del Coronavirus/inmunología , Glicoproteína de la Espiga del Coronavirus/metabolismo
20.
Am J Trop Med Hyg ; 105(2): 378-386, 2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34181574

RESUMEN

Antibody tests can be tools for detecting current or past severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2 [coronavirus disease 2019 (COVID-19)]) infections. Independent test evaluations are needed to document the performance with different sample sets. We evaluated six lateral flow assays (LFAs) and two laboratory-based tests (EUROIMMUN-SARS-CoV-2 ELISA and Abbott-Architect-SARS-CoV-2-IgG). We tested 210 plasma samples from 89 patients diagnosed with acute COVID-19. These samples were collected at different time points after the onset of symptoms. In addition, 80 convalescent plasma samples, and 168 pre-pandemic samples collected from adults in the United States and in Africa were tested. LFA performance varied widely, and some tests with high sensitivity had low specificity. LFA sensitivities were low (18.8-40.6%) for samples collected 0 to 3 days after symptom onset, and were greater (80.3-96.4%) for samples collected > 14 days after symptom onset. These results are similar to those obtained by ELISA (15.6% and 89.1%) and chemiluminescent microparticle assay (21.4% and 93.1%). The range of test specificity was between 82.7% and 97%. The combined use of two LFAs can increase specificity to more than 99% without a major loss of sensitivity. Because of suboptimal sensitivity with early COVID-19 samples and background reactivity with some pre-pandemic samples, none of the evaluated tests alone is reliable enough for definitive diagnosis of COVID-19 infection. However, antibody testing may be useful for assessing the status of the epidemic or vaccination campaign. Some of the LFAs had sensitivities and specificities that were comparable to those of more expensive laboratory tests, and these may be useful for seroprevalence surveys in resource-limited settings.


Asunto(s)
Anticuerpos Antivirales/sangre , Prueba Serológica para COVID-19/normas , COVID-19/diagnóstico , Inmunoensayo/normas , Juego de Reactivos para Diagnóstico/normas , SARS-CoV-2/inmunología , África , COVID-19/sangre , COVID-19/inmunología , Prueba Serológica para COVID-19/instrumentación , Prueba Serológica para COVID-19/métodos , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Inmunoglobulina G/sangre , Inmunoglobulina M/sangre , Estudios Retrospectivos , Sensibilidad y Especificidad