Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.391
Filtrar
2.
PLoS One ; 19(5): e0302302, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38768129

RESUMEN

BACKGROUND: Antibiotics are prescribed for over 50% of respiratory tract infections in primary care, despite good evidence of there being no benefit to the patient, and evidence of over prescribing driving microbial resistance. The high treatment rates are attributed to uncertainty regarding microbiological cause and clinical prognosis. Point-of-care-tests have been proposed as potential antibiotic stewardship tools, with some providing microbiological results in 15 minutes. However, there is little research on their impact on antibiotic use and clinical outcomes in primary care. METHODS: This is a multi-centre, individually randomised controlled trial with mixed-methods investigation of microbial, behavioural and antibiotic mechanisms on outcomes in patients aged 12 months and over presenting to primary care in the UK with a suspected respiratory tract infection, where the clinician and/or patient thinks antibiotic treatment may be, or is, necessary. Once consented, all participants are asked to provide a combined nose and throat swab sample and randomised to have a rapid microbiological point-of-care-test or no point-of-care-test. For intervention patients, clinicians review the result of the test, before contacting the patient to finalise treatment. Treatment decisions are made as per usual care in control group patients. The primary outcome is whether an antibiotic is prescribed at this point. All swab samples are sent to the central laboratory for further testing. Patients are asked to complete a diary to record the severity and duration of symptoms until resolution or day 28, and questionnaires at 2 months about their beliefs and intention to consult for similar future illnesses. Primary care medical records are also reviewed at 6-months to collect further infection consultations, antibiotic prescribing and hospital admissions. The trial aims to recruit 514 patients to achieve 90% power with 5% significance to detect a 15% absolute reduction in antibiotic prescribing. Qualitative interviews are being conducted with approximately 20 clinicians and 30 participants to understand any changes in beliefs and behaviour resulting from the point-of-care-test and generate attributes for clinician and patient discrete choice experiments. DISCUSSION: This trial will provide evidence of efficacy, acceptability and mechanisms of action of a rapid microbiological point-of-care test on antibiotic prescribing and patient symptoms in primary care. TRIAL REGISTRATION: ISRCTN16039192, prospectively registered on 08/11/2022.


Asunto(s)
Antibacterianos , Pruebas en el Punto de Atención , Atención Primaria de Salud , Infecciones del Sistema Respiratorio , Humanos , Antibacterianos/uso terapéutico , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Infecciones del Sistema Respiratorio/microbiología , Infecciones del Sistema Respiratorio/diagnóstico , Ensayos Clínicos Controlados Aleatorios como Asunto , Femenino , Programas de Optimización del Uso de los Antimicrobianos/métodos , Masculino , Sistemas de Atención de Punto
3.
PLoS One ; 19(5): e0303520, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38768171

RESUMEN

INTRODUCTION: Sickle cell disease (SCD) remains a public health problem especially in sub-Saharan Africa including Ghana. While pilot initiatives in Africa have demonstrated that neonatal screening coupled with early intervention reduces SCD-related morbidity and mortality, only 50-70% of screen-positive babies have been successfully retrieved to benefit from these interventions. Point-of-care testing (POCT) with high specificity and sensitivity for SCD screening can be integrated into existing immunization programs in Africa to improve retrieval rates. This study explored community acceptability of integrating POCT to screen for SCD in children under 5 years of age in primary healthcare facilities in Northern Ghana. METHOD: This was an exploratory study using qualitative research approach where 10 focus group discussions and 20 in-depth interviews were conducted with community members and health workers between April and June 2022. The recorded interviews were transcribed verbatim after repeatedly listening to the recordings. Data was coded into themes using QSR Nvivo 12 software before thematic analysis. RESULTS: Most participants (70.9%) described SCD as serious and potentially life-threatening condition affecting children in the area. Of 148 community members and health workers, 141 (95.2%) said the screening exercise could facilitate diagnosis of SCD in children for early management. However, discrimination, fear of being tested positive, stigmatization, negative health worker attitude linked with issues of maintaining confidentiality were reported by participants as key factors that could affect uptake of the SCD screening exercise. Most participants suggested that intensive health education (78.3%), positive attitude of health workers (69.5%), and screening health workers not being biased (58.8%) could promote community acceptability. CONCLUSION: A large majority of participants viewed screening of SCD in children as very important. However, opinions expressed by most participants suggest that health education and professionalism of health workers in keeping patients' information confidential could improve the uptake of the exercise.


Asunto(s)
Anemia de Células Falciformes , Pruebas en el Punto de Atención , Atención Primaria de Salud , Humanos , Anemia de Células Falciformes/diagnóstico , Anemia de Células Falciformes/psicología , Ghana , Femenino , Masculino , Preescolar , Adulto , Población Rural , Lactante , Aceptación de la Atención de Salud , Personal de Salud/psicología , Tamizaje Masivo/métodos , Persona de Mediana Edad , Recién Nacido , Adulto Joven , Grupos Focales
4.
Biosens Bioelectron ; 258: 116315, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38701536

RESUMEN

Research in electrochemical detection in lateral flow assays (LFAs) has gained significant momentum in recent years. The primary impetus for this surge in interest is the pursuit of achieving lower limits of detection, especially given that LFAs are the most widely employed point-of-care biosensors. Conventionally, the strategy for merging electrochemistry and LFAs has centered on the superposition of screen-printed electrodes onto nitrocellulose substrates during LFA fabrication. Nevertheless, this approach poses substantial limitations regarding scalability. In response, we have developed a novel method for the complete integration of reduced graphene oxide (rGO) electrodes into LFA strips. We employed a CO2 laser to concurrently reduce graphene oxide and pattern nitrocellulose, exposing its backing to create connection sites impervious to sample leakage. Subsequently, rGO and nitrocellulose were juxtaposed and introduced into a roll-to-roll system using a wax printer. The exerted pressure facilitated the transfer of rGO onto the nitrocellulose. We systematically evaluated several electrochemical strategies to harness the synergy between rGO and LFAs. While certain challenges persist, our rGO transfer technology presents compelling potential for setting a new standard in electrochemical LFA fabrication.


Asunto(s)
Técnicas Biosensibles , Técnicas Electroquímicas , Electrodos , Grafito , Sistemas de Atención de Punto , Grafito/química , Técnicas Biosensibles/instrumentación , Técnicas Biosensibles/métodos , Técnicas Electroquímicas/métodos , Técnicas Electroquímicas/instrumentación , Humanos , Diseño de Equipo , Colodión/química , Pruebas en el Punto de Atención , Límite de Detección , Oxidación-Reducción
5.
BMC Infect Dis ; 24(1): 481, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730343

RESUMEN

BACKGROUND: Tuberculosis (TB) poses a major public health challenge, particularly in children. A substantial proportion of children with TB disease remain undetected and unconfirmed. Therefore, there is an urgent need for a highly sensitive point-of-care test. This study aims to assess the performance of serological assays based on various antigen targets and antibody properties in distinguishing children (0-18 years) with TB disease (1) from healthy TB-exposed children, (2) children with non-TB lower respiratory tract infections, and (3) from children with TB infection. METHODS: The study will use biobanked plasma samples collected from three prospective multicentric diagnostic observational studies: the Childhood TB in Switzerland (CITRUS) study, the Pediatric TB Research Network in Spain (pTBred), and the Procalcitonin guidance to reduce antibiotic treatment of lower respiratory tract infections in children and adolescents (ProPAED) study. Included are children diagnosed with TB disease or infection, healthy TB-exposed children, and sick children with non-TB lower respiratory tract infection. Serological multiplex assays will be performed to identify M. tuberculosis antigen-specific antibody features, including isotypes, subclasses, Fc receptor (FcR) binding, and IgG glycosylation. DISCUSSION: The findings from this study will help to design serological assays for diagnosing TB disease in children. Importantly, those assays could easily be developed as low-cost point-of-care tests, thereby offering a potential solution for resource-constrained settings. GOV IDENTIFIER: NCT03044509.


Asunto(s)
Pruebas Serológicas , Tuberculosis , Adolescente , Niño , Preescolar , Femenino , Humanos , Lactante , Recién Nacido , Masculino , Anticuerpos Antibacterianos/sangre , Antígenos Bacterianos/inmunología , Mycobacterium tuberculosis/inmunología , Pruebas en el Punto de Atención , Estudios Prospectivos , Pruebas Serológicas/métodos , España , Suiza , Tuberculosis/diagnóstico , Tuberculosis/sangre
6.
BMC Endocr Disord ; 24(1): 60, 2024 May 06.
Artículo en Inglés | MEDLINE | ID: mdl-38711112

RESUMEN

BACKGROUND: Worldwide, up to 20 % of hospitalised patients have diabetes mellitus. In-hospital dysglycaemia increases patient mortality, morbidity, and length of hospital stay. Improved in-hospital diabetes management strategies are needed. The DIATEC trial investigates the effects of an in-hospital diabetes team and operational insulin titration algorithms based on either continuous glucose monitoring (CGM) data or standard point-of-care (POC) glucose testing. METHODS: This is a two-armed, two-site, prospective randomised open-label blinded endpoint (PROBE) trial. We recruit non-critically ill hospitalised general medical and orthopaedic patients with type 2 diabetes treated with basal, prandial, and correctional insulin (N = 166). In both arms, patients are monitored by POC glucose testing and diabetes management is done by ward nurses guided by in-hospital diabetes teams. In one of the arms, patients are monitored in addition to POC glucose testing by telemetric CGM viewed by the in-hospital diabetes teams only. The in-hospital diabetes teams have operational algorithms to titrate insulin in both arms. Outcomes are in-hospital glycaemic and clinical outcomes. DISCUSSION: The DIATEC trial will show the glycaemic and clinical effects of in-hospital CGM handled by in-hospital diabetes teams with access to operational insulin titration algorithms in non-critically ill patients with type 2 diabetes. The DIATEC trial seeks to identify which hospitalised patients will benefit from CGM and in-hospital diabetes teams compared to POC glucose testing. This is essential information to optimise the use of healthcare resources before broadly implementing in-hospital CGM and diabetes teams. TRIAL REGISTRATION: Prospectively registered at ClinicalTrials.gov with identification number NCT05803473 on March 27th 2023.


Asunto(s)
Automonitorización de la Glucosa Sanguínea , Glucemia , Diabetes Mellitus Tipo 2 , Humanos , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/sangre , Glucemia/análisis , Automonitorización de la Glucosa Sanguínea/métodos , Estudios Prospectivos , Pruebas en el Punto de Atención , Femenino , Masculino , Hospitalización , Insulina/uso terapéutico , Insulina/administración & dosificación , Hipoglucemiantes/uso terapéutico , Grupo de Atención al Paciente , Adulto , Persona de Mediana Edad , Monitoreo Continuo de Glucosa
7.
BMC Pediatr ; 24(1): 323, 2024 May 10.
Artículo en Inglés | MEDLINE | ID: mdl-38730340

RESUMEN

BACKGROUND: Sickle cell disease (SCD), a noncommunicable disease, has the greatest burden in sub-Saharan Africa. The majority of children (50-90%) with SCD die before their 5th birthday, with approximately 150,000-300,000 annual SCD child deaths in Africa. In developed countries, newborn screening (NBS) has been shown to improve the survival of children with sickle cell disease, with under5 childhood mortality reduced tenfold due to interventions performed before the development of complications. Point -of-care tests have been developed for resource limited settings to expand NBS. The aim of this study was to determine the birth prevalence of sickle cell disease in Namibia using the HemoTypeSC™ point-of-care test. METHODS: A cross-sectional descriptive study was carried out at Rundu Intermediate Hospital in the Kavango East Region. Two hundred and two (202) well newborns within 72 h of birth were recruited for the study from 22 February to the 23th March 2023. Descriptive statistics were used to compute the haemoglobin types of the study participants. RESULTS: The majority of the participants (n = 105, 52%) were females, and (n = 97,48%) were males. The median age of the participants was 23 h (Q1, Q3; 11; 33),) with an age range of 2-98 h. Sickle cell trait was present in 9.4% of the screened newborns, no homozygous disease was detected, and 90.6% had Hb AA. CONCLUSIONS: This study is the first to measure HbS gene carriage at birth using HemotypeSC point-of-care testing in Namibia. There was a moderate prevalence of sickle cell traits but no SCD. This baseline study may provide the foundation for larger epidemiological surveys to map HbS gene carriage in Namibia to provide evidence for policy makers to fashion appropriate SCD newborn screening services.


Asunto(s)
Anemia de Células Falciformes , Tamizaje Neonatal , Pruebas en el Punto de Atención , Humanos , Anemia de Células Falciformes/epidemiología , Anemia de Células Falciformes/diagnóstico , Anemia de Células Falciformes/genética , Recién Nacido , Estudios Transversales , Namibia/epidemiología , Prevalencia , Femenino , Masculino , Tamizaje Neonatal/métodos
8.
Trials ; 25(1): 298, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38698471

RESUMEN

BACKGROUND: The use of antibiotics is a key driver of antimicrobial resistance and is considered a major threat to global health. In Denmark, approximately 75% of antibiotic prescriptions are issued in general practice, with acute lower respiratory tract infections (LRTIs) being one of the most common indications. Adults who present to general practice with symptoms of acute LRTI often suffer from self-limiting viral infections. However, some patients have bacterial community-acquired pneumonia (CAP), a potential life-threatening infection, that requires immediate antibiotic treatment. Importantly, no single symptom or specific point-of-care test can be used to discriminate the various diagnoses, and diagnostic uncertainty often leads to (over)use of antibiotics. At present, general practitioners (GPs) lack tools to better identify those patients who will benefit from antibiotic treatment. The primary aim of the PLUS-FLUS trial is to determine whether adults who present with symptoms of an acute LRTI in general practice and who have FLUS performed in addition to usual care are treated less frequently with antibiotics than those who only receive usual care. METHODS: Adults (≥ 18 years) presenting to general practice with acute cough (< 21 days) and at least one other symptom of acute LRTI, where the GP suspects a bacterial CAP, will be invited to participate in this pragmatic randomized controlled trial. All participants will receive usual care. Subsequently, participants will be randomized to either the control group (usual care) or to an additional focused lung ultrasonography performed by the GP (+ FLUS). The primary outcome is the proportion of participants with antibiotics prescribed at the index consultation (day 0). Secondary outcomes include comparisons of the clinical course for participants in groups. DISCUSSION: We will examine whether adults who present with symptoms of acute LRTI in general practice, who have FLUS performed in addition to usual care, have antibiotics prescribed less frequently than those given usual care alone. It is highly important that a possible reduction in antibiotic prescriptions does not compromise patients' recovery or clinical course, which we will assess closely. TRIAL REGISTRATION: ClinicalTrials.gov NCT06210282. Registered on January 17, 2024.


Asunto(s)
Antibacterianos , Medicina General , Pulmón , Pautas de la Práctica en Medicina , Ensayos Clínicos Pragmáticos como Asunto , Infecciones del Sistema Respiratorio , Ultrasonografía , Humanos , Antibacterianos/uso terapéutico , Dinamarca , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Infecciones del Sistema Respiratorio/diagnóstico por imagen , Infecciones del Sistema Respiratorio/microbiología , Pulmón/diagnóstico por imagen , Pulmón/microbiología , Enfermedad Aguda , Resultado del Tratamiento , Prescripciones de Medicamentos , Pruebas en el Punto de Atención , Adulto
9.
Sex Transm Dis ; 51(6): 388-392, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38733972

RESUMEN

BACKGROUND: Standard-of-care nucleic acid amplification tests (routine NAATs) for Neisseria gonorrhoeae (GC) and Chlamydia trachomatis (CT) can take several days to result and therefore delay treatment. Rapid point-of-care GC/CT NAAT (rapid NAAT) could reduce the time to treatment and therefore onward transmission. This study evaluated the incremental cost per infectious day averted and overall cost of implementation associated with rapid compared with routine NAAT. METHODS: Prospective sexually transmitted infection (STI) treatment data from men who have sex with men and transgender women in San Diego who received rapid NAAT between November 2018 and February 2021 were evaluated. Historical time from testing to treatment for routine NAAT was abstracted from the literature. Costs per test for rapid and routine NAAT were calculated using a micro-costing approach. The incremental cost per infectious day averted comparing rapid to routine NAAT and the costs of rapid GC/CT NAAT implementation in San Diego Public Health STI clinics were calculated. RESULTS: Overall, 2333 individuals underwent rapid NAAT with a median time from sample collection to treatment of 2 days compared with 7 to 14 days for routine NAAT equating to a reduction of 5 to 12 days. The cost of rapid and routine GC/CT NAAT was $57.86 and $18.38 per test, respectively, with a cost-effectiveness of between $2.43 and $5.82 per infectious day averted. The incremental cost of rapid NAAT improved when at least 2000 tests were performed annually. CONCLUSIONS: Although rapid GC/CT NAAT is more expensive than routine testing, the reduction of infectious days between testing and treatment may reduce transmission and provide improved STI treatment services to patients.


Asunto(s)
Infecciones por Chlamydia , Chlamydia trachomatis , Gonorrea , Homosexualidad Masculina , Neisseria gonorrhoeae , Técnicas de Amplificación de Ácido Nucleico , Humanos , Masculino , Gonorrea/diagnóstico , Gonorrea/economía , Infecciones por Chlamydia/diagnóstico , Infecciones por Chlamydia/economía , Técnicas de Amplificación de Ácido Nucleico/economía , Neisseria gonorrhoeae/aislamiento & purificación , Chlamydia trachomatis/aislamiento & purificación , Adulto , California/epidemiología , Análisis Costo-Beneficio , Estudios Prospectivos , Femenino , Pruebas en el Punto de Atención/economía , Personas Transgénero
10.
BMJ Open ; 14(5): e084918, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38692732

RESUMEN

INTRODUCTION: A prototype lateral flow device detecting cytokine biomarkers interleukin (IL)-1α and IL-1ß has been developed as a point-of-care test-called the Genital InFlammation Test (GIFT)-for detecting genital inflammation associated with sexually transmitted infections (STIs) and/or bacterial vaginosis (BV) in women. In this paper, we describe the rationale and design for studies that will be conducted in South Africa, Zimbabwe and Madagascar to evaluate the performance of GIFT and how it could be integrated into routine care. METHODS AND ANALYSIS: We will conduct a prospective, multidisciplinary, multicentre, cross-sectional and observational clinical study comprising two distinct components: a biomedical ('diagnostic study') and a qualitative, modelling and economic ('an integration into care study') part. The diagnostic study aims to evaluate GIFT's performance in identifying asymptomatic women with discharge-causing STIs (Chlamydia trachomatis (CT), Neisseria gonorrhoeae (NG), Trichomonas vaginalis (TV) and Mycoplasma genitalium (MG)) and BV. Study participants will be recruited from women attending research sites and family planning services. Several vaginal swabs will be collected for the evaluation of cytokine concentrations (ELISA), STIs (nucleic acid amplification tests), BV (Nugent score) and vaginal microbiome characteristics (16S rRNA gene sequencing). The first collected vaginal swab will be used for the GIFT assay which will be performed in parallel by a healthcare worker in the clinic near the participant, and by a technician in the laboratory. The integration into care study aims to explore how GIFT could be integrated into routine care. Four activities will be conducted: user experiences and/or perceptions of the GIFT device involving qualitative focus group discussions and in-depth interviews with key stakeholders; discrete choice experiments; development of a decision tree classification algorithm; and economic evaluation of defined management algorithms. ETHICS AND DISSEMINATION: Findings will be reported to participants, collaborators and local government for the three sites, presented at national and international conferences, and disseminated in peer-reviewed publications.The protocol and all study documents such as informed consent forms were reviewed and approved by the University of Cape Town Human Research Ethics Committee (HREC reference 366/2022), Medical Research Council of Zimbabwe (MRCZ/A/2966), Comité d'Ethique pour la Recherche Biomédicale de Madagascar (N° 143 MNSAP/SG/AMM/CERBM) and the London School of Hygiene and Tropical Medicine ethics committee (LSHTM reference 28046).Before the start, this study was submitted to the Clinicaltrials.gov public registry (NCT05723484). TRIAL REGISTRATION NUMBER: NCT05723484.


Asunto(s)
Biomarcadores , Enfermedades de Transmisión Sexual , Vaginosis Bacteriana , Humanos , Femenino , Vaginosis Bacteriana/diagnóstico , Estudios Prospectivos , Biomarcadores/análisis , Enfermedades de Transmisión Sexual/diagnóstico , Estudios Transversales , Pruebas en el Punto de Atención , Estudios de Factibilidad , Interleucina-1alfa/metabolismo , Interleucina-1alfa/análisis , Interleucina-1beta/análisis , Adulto , Citocinas/metabolismo , Citocinas/análisis , Sudáfrica , Zimbabwe , Estudios Observacionales como Asunto , Estudios Multicéntricos como Asunto
11.
NPJ Prim Care Respir Med ; 34(1): 9, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38724543

RESUMEN

This cluster randomised clinical trial carried out in 20 primary care centres in Barcelona was aimed at assessing the effect of a continuous intervention focused on C-reactive protein (CRP) rapid testing and training in enhanced communication skills (ECS) on antibiotic consumption for adults with acute cough due to lower respiratory tract infection (LRTI). The interventions consisted of general practitioners and nurses' use of CRP point-of-care and training in ECS separately and combined, and usual care. The primary outcomes were antibiotic consumption and variation of the quality-adjusted life years during a 6-week follow-up. The difference in the overall antibiotic prescribing between the winter seasons before and after the intervention was calculated. The sample size calculated could not be reached due to the COVID-19 outbreak. A total of 233 patients were recruited. Compared to the usual care group (56.7%) antibiotic consumption among patients assigned to professionals in the ECS group was significantly lower (33.9%, adjusted odds ratio [aOR] 0.38, 95% CI 0.15-0.94, p = 0.037), whereas patients assigned to CRP consumed 43.8% of antibiotics (aOR 0.70, 95% CI 0.29-1.68, p = 0.429) and 38.4% in the combined intervention group (aOR 0.45, 95% CI, 0.17-1.21; p = 0.112). The overall antibiotic prescribing rates in the centres receiving training were lower after the intervention compared to those assigned to usual care, with significant reductions in ß-lactam rates. Patient recovery was similar in all groups. Despite the limited power due to the low number of patients included, we observed that continuous training achieved reductions in antibiotic consumption.


Asunto(s)
Antibacterianos , Proteína C-Reactiva , Tos , Humanos , Antibacterianos/uso terapéutico , Proteína C-Reactiva/metabolismo , Proteína C-Reactiva/análisis , Masculino , Femenino , Persona de Mediana Edad , Tos/tratamiento farmacológico , Adulto , Comunicación , Enfermedad Aguda , Infecciones del Sistema Respiratorio/tratamiento farmacológico , Pautas de la Práctica en Medicina/estadística & datos numéricos , Anciano , Atención Primaria de Salud/métodos , COVID-19/complicaciones , España , Pruebas en el Punto de Atención
12.
J Pharm Biomed Anal ; 245: 116194, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38704878

RESUMEN

A miniature mass spectrometer (mMS) based point-of-care testing (POCT) method was evaluated for on-site detecting the hypertension drugs, amlodipine and benazepril. The instrument parameters, including voltage, ISO1, ISO2, and CID, were optimized, under which the target compounds could be well detected in MS2. When these two drugs were injected simultaneously, the mutual ionization inhibition and mutual reduction between amlodipine and benazepril were evaluated. This phenomenon was severe on the precursor ions but had a small impact on the product ions, thus making this POCT method suitable for analysis using product ions. Finally, the method was validated and applied. The blood samples from patients were tested one hour after oral administration of the drugs (20 mg), and the benazepril was quantitatively analyzed using a standard curve, with detected concentrations ranging from 190.6 to 210 µg L-1 and a relative standard deviation (RSD) of 8.6 %. In summary, amlodipine has low sensitivity and can only be detected at higher concentrations, while benazepril has high sensitivity, good linearity, and even meets semi-quantitative requirements. The research results of this study are of great clinical significance for monitoring blood drug concentrations during hypertension medication, predicting drug efficacy, and customizing individualized medication plans.


Asunto(s)
Amlodipino , Antihipertensivos , Benzazepinas , Amlodipino/sangre , Humanos , Benzazepinas/sangre , Antihipertensivos/sangre , Antihipertensivos/administración & dosificación , Espectrometría de Masas/métodos , Pruebas en el Punto de Atención , Reproducibilidad de los Resultados , Límite de Detección , Sistemas de Atención de Punto
13.
AIDS Res Ther ; 21(1): 33, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755626

RESUMEN

BACKGROUND: HIV early infant diagnosis (HEID) at the centralized laboratory faces many challenges that impact the cascade of timely HEID. Point of Care (PoC) HEID has shown to reduce test turnaround times, allow for task shifting and has the potential to reduce infant mortality. We aimed at assessing the feasibility of nurse based PoC-HEID in five facilities of Mbeya region. METHODS: We analysed data from healthcare workers at five obstetric health facilities that participated in the BABY study which enrolled mothers living with HIV and their HIV exposed infants who were followed up until 6 weeks post-delivery. Nurses and laboratory personnel were trained and performed HEID procedures using the Xpert HIV-1 Qual PoC systems. Involved personnel were interviewed on feasibility, knowledge and competency of procedures and overall impression of the use of HIV-1 Qual PoC system in clinical settings. RESULTS: A total of 28 health care workers (HCWs) who participated in the study between 2014 and 2016 were interviewed, 23 being nurses, 1 clinical officer, 1 lab scientist and 3 lab technicians The median age was 39.5 years. Majority of the nurses (22/24) and all lab staff were confident using Gene Xpert PoC test after being trained. None of them rated Gene Xpert handling as too complicated despite minor challenges. Five HCWs (5/24) reported power cut as the most often occurring problem. As an overall impression, all interviewees agreed on PoC HEID to be used in clinical settings however, about half of them (11/24) indicated that the PoC-HEID procedures add a burden onto their routine workload. CONCLUSION: Overall, health care workers in our study demonstrated very good perceptions and experiences of using PoC HEID. Efforts should be invested on quality training, targeted task distribution at the clinics, continual supportive supervision and power back up mechanisms to make the wide-scale adoption of nurse based PoC HEID testing a possibility.


Asunto(s)
Diagnóstico Precoz , Infecciones por VIH , VIH-1 , Personal de Salud , Pruebas en el Punto de Atención , Humanos , Infecciones por VIH/diagnóstico , Femenino , Tanzanía , Lactante , Recién Nacido , Adulto , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Masculino , Prueba de VIH/métodos , Embarazo , Actitud del Personal de Salud
14.
Methods Mol Biol ; 2804: 3-50, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38753138

RESUMEN

Self-powered microfluidics presents a revolutionary approach to address the challenges of healthcare in decentralized and point-of-care settings where limited access to resources and infrastructure prevails or rapid clinical decision-making is critical. These microfluidic systems exploit physical and chemical phenomena, such as capillary forces and surface tension, to manipulate tiny volumes of fluids without the need for external power sources, making them cost-effective and highly portable. Recent technological advancements have demonstrated the ability to preprogram complex multistep liquid operations within the microfluidic circuit of these standalone systems, which enabled the integration of sensitive detection and readout principles. This chapter first addresses how the accessibility to in vitro diagnostics can be improved by shifting toward decentralized approaches like remote microsampling and point-of-care testing. Next, the crucial role of self-powered microfluidic technologies to enable this patient-centric healthcare transition is emphasized using various state-of-the-art examples, with a primary focus on applications related to biofluid collection and the detection of either proteins or nucleic acids. This chapter concludes with a summary of the main findings and our vision of the future perspectives in the field of self-powered microfluidic technologies and their use for in vitro diagnostics applications.


Asunto(s)
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , Sistemas de Atención de Punto , Proteínas , Humanos , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Microfluídica/instrumentación , Ácidos Nucleicos/análisis , Pruebas en el Punto de Atención , Proteínas/análisis
15.
Biosens Bioelectron ; 258: 116326, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38696965

RESUMEN

In conventional clinical disease diagnosis and screening based on biomarker detection, most analysis samples are collected from serum, blood. However, these invasive collection methods require specific instruments, professionals, and may lead to infection risks. Additionally, the diagnosis process suffers from untimely results. The identification of skin-related biomarkers plays an unprecedented role in early disease diagnosis. More importantly, these skin-mediated approaches for collecting biomarker-containing biofluid samples are noninvasive or minimally invasive, which is more preferable for point-of-care testing (POCT). Therefore, skin-based biomarker detection patches have been promoted, owing to their unique advantages, such as simple fabrication, desirable transdermal properties and no requirements for professional medical staff. Currently, the skin biomarkers extracted from sweat, interstitial fluid (ISF) and wound exudate, are achieved with wearable sweat patches, transdermal MN patches, and wound patches, respectively. In this review, we detail these three types of skin patches in biofluids collection and diseases-related biomarkers identification. Patch classification and the corresponding manufacturing as well as detection strategies are also summarized. The remaining challenges in clinical applications and current issues in accurate detection are discussed for further advancement of this technology (Scheme 1).


Asunto(s)
Biomarcadores , Técnicas Biosensibles , Piel , Sudor , Dispositivos Electrónicos Vestibles , Humanos , Biomarcadores/sangre , Biomarcadores/análisis , Técnicas Biosensibles/métodos , Técnicas Biosensibles/instrumentación , Sudor/química , Piel/química , Piel/patología , Líquido Extracelular/química , Diseño de Equipo , Pruebas en el Punto de Atención , Líquidos Corporales/química
16.
AIDS Res Ther ; 21(1): 31, 2024 May 15.
Artículo en Inglés | MEDLINE | ID: mdl-38750529

RESUMEN

BACKGROUND: Uganda Ministry of Health (MOH) recommends a first HIV DNA-PCR test at 4-6 weeks for early infant diagnosis (EID) of HIV-exposed infants (HEI) and immediate return of results. WHO recommends initiating antiretroviral therapy (ART) ≤ 7 days from HIV diagnosis. In 2019, MOH introduced point-of-care (POC) whole-blood EID testing in 33 health facilities and scaled up to 130 facilities in 2020. We assessed results turnaround time and ART linkage pre-POC and during POC testing. METHODS: We evaluated EID register data for HEI at 10 health facilities with POC and EID testing volume of ≥ 12 infants/month from 2018 to 2021. We abstracted data for 12 months before and after POC testing rollout and compared time to sample collection, results receipt, and ART initiation between periods using medians, Wilcoxon, and log-rank tests. RESULTS: Data for 4.004 HEI were abstracted, of which 1.685 (42%) were from the pre-POC period and 2.319 (58%) were from the period during POC; 3.773 (94%) had a first EID test (pre-POC: 1.649 [44%]; during POC: 2.124 [56%]). Median age at sample collection was 44 (IQR 38-51) days pre-POC and 42 (IQR 33-50) days during POC (p < 0.001). Among 3.773 HEI tested, 3.678 (97%) had test results. HIV-positive infants' (n = 69) median age at sample collection was 94 (IQR 43-124) days pre-POC and 125 (IQR 74-206) days during POC (p = 0.04). HIV positivity rate was 1.6% (27/1.617) pre-POC and 2.0% (42/2.061) during POC (p = 0.43). For all infants, median days from sample collection to results receipt by infants' caregivers was 28 (IQR 14-52) pre-POC and 1 (IQR 0-25) during POC (p < 0.001); among HIV-positive infants, median days were 23 (IQR 7-30) pre-POC and 0 (0-3) during POC (p < 0.001). Pre-POC, 4% (1/23) HIV-positive infants started ART on the sample collection day compared to 33% (12/37) during POC (p < 0.001); ART linkage ≤ 7 days from HIV diagnosis was 74% (17/23) pre-POC and 95% (35/37) during POC (p < 0.001). CONCLUSION: POC testing improved EID results turnaround time and ART initiation for HIV-positive infants. While POC testing expansion could further improve ART linkage and loss to follow-up, there is need to explore barriers around same-day ART initiation for infants receiving POC testing.


Asunto(s)
Diagnóstico Precoz , Infecciones por VIH , Pruebas en el Punto de Atención , Humanos , Uganda/epidemiología , Lactante , Infecciones por VIH/tratamiento farmacológico , Infecciones por VIH/diagnóstico , Femenino , Recién Nacido , Masculino , Fármacos Anti-VIH/uso terapéutico , Transmisión Vertical de Enfermedad Infecciosa/prevención & control , Prueba de VIH/estadística & datos numéricos , Antirretrovirales/uso terapéutico
17.
Ter Arkh ; 96(3): 312-314, 2024 Apr 16.
Artículo en Ruso | MEDLINE | ID: mdl-38713050

RESUMEN

In the article "Point-of-care blood glucose testing: post-market performance assessment of the Accu-Chek Inform II hospital-use glucose meter," published in the Terapevticheskii Arkhiv journal, Vol. 95, No.12, 2023 (DOI: 10.26442/00403660.2023.12.202522), errors were made: the term "measurements at the place of treatment" was changed, as well as the section "Conflict of interest." At the request of the authors' team, errors in the conflict of interest and the wording of the term have been corrected, and the section "Information about the authors" has been updated. The publisher replaced the original version of the published article with the corrected one; the information on the website was also corrected. Correct text of the section "Conflict of interest": Conflict of interest. All authors are not employees or consultants of Roche Diagnostics and have not received any compensation from Roche Diagnostics. Correct wording of the term in Russian: "измерения по месту лечения". Changes were made to the title of the article in Russian: "Измерения глюкозы по месту лечения: пострегистрационное испытание госпитального глюкометра Акку-Чек Информ II", the text of the abstract, keywords, citation, in the text of the article, and abbreviations. Information of the place of work has been updated: Center for Laboratory Diagnostics of the Russian Children Clinical Hospital, a Branch of the Pirogov Russian National Research Medical University. The publisher apologizes to readers and authors for the errors and is confident that the correction of errors will ensure the correct perception and interpretation of the results of the study described in the text.


Asunto(s)
Glucemia , Humanos , Glucemia/análisis , Sistemas de Atención de Punto , Automonitorización de la Glucosa Sanguínea/instrumentación , Automonitorización de la Glucosa Sanguínea/métodos , Pruebas en el Punto de Atención , Vigilancia de Productos Comercializados/métodos , Federación de Rusia
18.
Front Public Health ; 12: 1360322, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38721545

RESUMEN

Introduction: Point-of-Care Tests (POCTs) are utilized daily in resource abundant regions, however, are limited in the global south, particularly in the prehospital setting. Few studies exist on the use of non-malarial POCTs by Community Health Workers (CHWs). The purpose of this scoping review is to delineate the current diversity in and breadth of POCTs evaluated in the prehospital setting. Methods: A medical subject heading (MeSH) analysis of known key articles was done by an experienced medical librarian and scoping searches were performed in each database to capture "point of care testing" and "community health workers." This review was guided by the PRISMA Extension for scoping reviews. Results: 2735 publications were returned, 185 were nominated for full-text review, and 110 studies were confirmed to meet study criteria. Majority focused on malaria (74/110; 67%) or HIV (25/110; 23%); 9/110 (8%) described other tests administered. Results from this review demonstrate a broad geographic range with significant heterogeneity in terminology for local CHWs. Conclusion: The use of new POCTs is on the rise and may improve early risk stratification in limited resource settings. Current evidence from decades of malaria POCTs can guide future implementation strategies.


Asunto(s)
Agentes Comunitarios de Salud , Pruebas en el Punto de Atención , Humanos , Pruebas en el Punto de Atención/estadística & datos numéricos , Servicios Médicos de Urgencia/estadística & datos numéricos , Malaria/diagnóstico , Sistemas de Atención de Punto/estadística & datos numéricos
19.
West J Emerg Med ; 25(2): 268-274, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38596929

RESUMEN

Introduction: Numerous studies have demonstrated the accuracy of point-of-care ultrasound (POCUS). Portable, handheld devices have expanded the clinical scope of POCUS at a fraction of the cost of traditional, cart-based models. There is a paucity of data assessing the diagnostic accuracy of portable devices. Our objective in this study was to compare the diagnostic accuracy of a portable device with a cart-based model. Methods: This was an institutional review board-approved, observational, prospective, randomized clinical trial (NCT05196776) of a convenience sample of adult patients who presented to a university-based health system. Patients who required a cardiac, lung, renal, aorta, or biliary POCUS were randomized to a portable device or to a cart-based model. We hypothesized that the cart-based model would have a 90% diagnostic accuracy vs 70% for the handheld device. To detect a 20% difference, the sample size was calculated to be 98, with 49 patients randomized to each arm. We used standard 2x2 tables to calculate test characteristics with 95% confidence intervals (CI). Results: A total of 110 patients were enrolled, with 56 patients randomized to the cart-based model and 54 to the handheld device. The sensitivity, specificity, and diagnostic accuracy of the cart-based vs handheld were 77.8% (40-97.2) vs 92.9% (66.1-99.8), 91.5% (79.6-97.6) vs 92.3% (79.1-98.4%), and 89.3% (78.1-96) vs 92.5% (81.8-97.9), respectively. Conclusion: The diagnostic accuracy of a portable, handheld device is similar to that of a cart-based model.


Asunto(s)
Pruebas en el Punto de Atención , Proyectos de Investigación , Adulto , Humanos , Estudios Prospectivos , Ultrasonografía
20.
Can J Vet Res ; 88(2): 55-65, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38595950

RESUMEN

Urinary bladder volume (UBV) can be estimated using point-of-care ultrasound. The purpose of this study was to compare 2 UBV estimation methods, i.e., three-dimensional (3D) bladder circumference tracing and 2-dimensional (2D) linear bladder dimension formula, against actual bladder volumes in awake client-owned cats and identify the best scanning position for UBV estimations. Up to 3 paired sets of orthogonal longitudinal and transverse bladder ultrasound images were acquired by a trained clinician from 21 cats positioned in dorsal, right lateral, and left lateral recumbency. UBV estimation was performed with these images by 2 different observers using both methods. Actual bladder volumes were measured through urethral catheterization and compared to the estimated UBV using Lin's concordance correlation coefficient and Bland-Altman analyses. Considering all positions, both methods showed substantial strength-of-agreement with actual bladder volumes; the 3D bladder circumference method (ρc = 0.963, 95% CI: 0.952 to 0.974) with a significant median bias of -4.08 mL (P < 0.001, IQR -7.63 to -0.68 mL, LOA -48.55 to 21.75 mL) and the 2D linear dimension method (ρc = 0.974, 95% CI: 0.966 to 0.982) with a median bias of -0.82 mL (P = 0.686, IQR -3.89 to 4.05 mL, LOA -35.23 to 35.21 mL). Scanning in left lateral recumbency provided the strongest strengths-of-agreement and precision against actual bladder volumes for both methods. Regardless of scanning positions, the 2D linear dimension method is more accurate than the 3D bladder circumference method, although both methods are imprecise with increasing volumes and UBV assessment through urinary catheterization remains the gold standard.


Le volume vésical (UBV) peut être estimé à l'aide de l'échographie au point d'intervention. L'objectif de cette étude fut de comparer 2 méthodes d'estimation du UBV, i.e., le tracé tridimensionnel (3D) de la circonférence de la vessie et la formule de dimension linéaire en 2 dimensions (2D), aux volumes vésicaux réels chez des chats éveillés appartenant à des clients, ainsi que d'identifier la meilleure position de balayage pour l'estimation du UBV. Jusqu'à 3 séries appariées d'images ultrasonores longitudinales et transverses orthogonales ont été acquises par une clinicienne qualifiée sur 21 chats positionnés en décubitus dorsal, latéral droit et latéral gauche. L'estimation du UBV a été réalisée à partir de ces images par 2 observateurs différents utilisant les 2 méthodes. Les volumes vésicaux réels ont été mesurés par cathétérisme urétral et comparés aux UBV estimés à l'aide du coefficient de corrélation de concordance de Lin et d'analyses de Bland-Altman. Toutes positions confondues, les 2 méthodes ont montré une concordance considérable avec les volumes vésicaux réels; la méthode de la circonférence vésicale 3D (ρc = 0,963, 95 % CI : 0,952 à 0,974) avec un biais médian significatif de −4,08 mL (P < 0,001, IQR −7,63 à −0,68 mL, LOA −48,55 à 21,75 mL) et la méthode de la dimension linéaire 2D (ρc = 0,974, 95 % CI : 0,966 à 0,982) avec un biais médian de −0,82 mL (P = 0,686, IQR −3,89 à 4,05 mL, LOA −35,23 à 35,21 mL). Le balayage en décubitus latéral gauche a démontré les meilleures concordance et précision par rapport aux volumes vésicaux réels pour les 2 méthodes. Quelle que soit la position de balayage, la méthode de la dimension linéaire 2D est plus précise que la méthode de circonférence vésicale 3D, bien que les 2 méthodes deviennent imprécises avec des volumes vésicaux plus élevés et que l'évaluation du UBV par cathétérisme urinaire demeure l'étalon d'or.(Traduit par les auteurs).


Asunto(s)
Pruebas en el Punto de Atención , Vejiga Urinaria , Gatos , Animales , Vejiga Urinaria/diagnóstico por imagen , Ultrasonografía/veterinaria , Ultrasonografía/métodos , Reproducibilidad de los Resultados
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA