Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.057
Filtrar
1.
Am J Dent ; 37(3): 141-146, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899994

RESUMEN

PURPOSE: To evaluate the effect of air abrasion and polishing procedures on roughness and color stability of ceramic and composite materials after artificial accelerated aging. METHODS: In this study, six restorative materials were tested: feldspathic ceramic (CEREC Blocks), glass ceramic (IPS e.max CAD), resin-based hybrid ceramic (Cerasmart), microhybrid composite (Charisma Classic), nanohybrid composite (Charisma Diamond) and nanoceramic composite (CeramXOne). Forty square-shaped composite specimens were fabricated from each composite and CAD-CAM ceramic material. Initial surface roughness measurements were performed using a profilometer and color measurements of each specimen with a spectrophotometer. Ten control specimens for each group did not receive air abrasion. The other specimens were treated by an air abrasion device and then were randomly divided into three subgroups of 10 specimens (n= 10). After air abrasion, 10 specimens of each group did not receive polishing (Air abrasion group) and others were repolished with Sof-Lex kit (Sof-Lex group) or a rubber kit (Rubber group). Surface roughness and color measurements were repeated before and after 300 hours of artificial accelerated aging (AAA). The univariate test and then three-way ANOVA and two-way ANOVA were performed for comparison of groups (α= 0.05). RESULTS: The univariate statistical analysis revealed that the restorative materials were differently affected after air abrasion, polishing methods and AAA (P< 0.001). Three-way ANOVA showed that the surface roughness of the restorative materials increased after air abrasion and AAA (P< 0.001). Two-way ANOVA showed statistically significant differences between color changes of ceramic (CEREC and IPS e.max CAD) and composite based restorative materials (P< 0.001). CLINICAL SIGNIFICANCE: Clinicians should be aware that air abrasion at a specified power and time significantly changes the surface roughness of the materials except for CEREC. Additionally, polishing procedures (Sof-Lex, Rubber) did not significantly reduce the surface roughness of the ceramic groups. After air abrasion, depending on the material type used clinically, restorations should be repolished to reduce roughness and ensure color stability.


Asunto(s)
Cerámica , Color , Resinas Compuestas , Pulido Dental , Porcelana Dental , Ensayo de Materiales , Propiedades de Superficie , Pulido Dental/métodos , Resinas Compuestas/química , Cerámica/química , Porcelana Dental/química , Materiales Dentales/química , Abrasión Dental por Aire , Factores de Tiempo , Diseño Asistido por Computadora , Silicatos de Aluminio/química , Espectrofotometría , Humanos , Compuestos de Potasio/química
2.
Am J Dent ; 37(3): 147-153, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899995

RESUMEN

PURPOSE: To investigate the discoloration, line roughness and gloss of conventional and universal shade resin-based composites. METHODS: Clearfil AP-X (AP-X) and Estelite Sigma Quick (EQ) samples were prepared. Discoloration, roughness, and gloss were measured on mirror-polished, alkaline-degraded, and repolished surfaces. The superficial layer degraded by alkaline immersion (degraded layer) was ground off from the sample surface. After removing the degraded layer, the surface was polished with aluminum oxide powder (1.0 µm and 0.3 µm), to create a repolished specimen. Scanning electron microscopy observations were made of the specimens. RESULTS: The results were compared with those for Omnichroma (OC) from a previous study. All the materials showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials. CLINICAL SIGNIFICANCE: The materials tested showed different responses to degradation and repolishing, but repolishing of AP-X, for surface roughness and gloss, was more effective at restoring pre-degradation properties. Repolishing effectively removed discoloration in all materials.


Asunto(s)
Color , Resinas Compuestas , Propiedades de Superficie , Resinas Compuestas/química , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Pulido Dental/métodos , Óxido de Aluminio/química
3.
Am J Dent ; 37(3): 159-163, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38899997

RESUMEN

PURPOSE: To evaluate different polishing methods' effects on the color stability of recent resin composites. METHODS: 160 samples for color stability evaluation and 40 samples for the degree of conversion evaluation were prepared with four different resin composites [Harmonize (H), Filtek Universal (F), Omnichroma (O), Essentia Universal (E)] and light cured. For color stability evaluation, samples prepared from each resin composite were divided into four groups: three polishing procedures and a control group. The ΔE00 was calculated between initial, and after immersion in coffee solution for 12 days. The degree of conversion was evaluated with Fourier Transform Infrared Spectroscopy. The statistical analysis of ΔE00 values was made with the two-way ANOVA, Tukey HSD, and Tamhane's T2 tests. One-way ANOVA and Tukey HSD tests were used to compare the degree of conversion values (P< 0.05). RESULTS: In all composite groups, mylar (control) groups had the highest ΔE00, and no differences between other polishing procedures. According to the polishing procedures, Omnichroma showed the highest ΔE00 values (on mylar groups O vs F, P< 0.001; O vs H, P< 0.001; O vs E, P< 0.001). There was a significant difference between the composite groups in terms of the degree of monomer conversion (P< 0.05). Omnichroma showed, significantly, the highest discoloration. CLINICAL SIGNIFICANCE: Different polishing procedures showed effective performance on current composite surfaces. Omnichroma resin composite showed higher color change than composites with similar properties.


Asunto(s)
Color , Resinas Compuestas , Pulido Dental , Resinas Compuestas/química , Pulido Dental/métodos , Propiedades de Superficie , Ensayo de Materiales , Espectroscopía Infrarroja por Transformada de Fourier
4.
BMC Oral Health ; 24(1): 712, 2024 Jun 20.
Artículo en Inglés | MEDLINE | ID: mdl-38902697

RESUMEN

OBJECTIVE: To evaluate the effects of different polishing techniques and coffee staining on the color stability of four commercially available bleach-shade composite resins, namely microhybrid, nanohybrid, nanofilled, and injectable nanohybrids. MATERIAL AND METHODS: A total of 224 discs (8 mm diameter and 2 mm thickness) were fabricated from four different bleach-shade composite resins, namely microhybrid (Gradia Direct Anterior), nanohybrid (Palfique LX5), nanofilled (Filtek Universal), and injectable nanohybrid (flowable G-aenial universal injectable). The composite resin groups were polished via four techniques: no polishing, 4-step polishing using aluminum oxide discs, 3-step polishing using silicon rubber diamond discs, and one-step polishing. Half of each group was immersed in water, while the other half was immersed in coffee for 12 days (n = 7). Colors were measured using a clinical spectrophotometer, and color differences were calculated (ΔE). The results were analyzed statistically. RESULTS: The alterations in color were significantly influenced by the techniques employed for finishing and polishing techniques, composite resin type, and degree of coffee staining. Regardless of the polishing technique and storage medium, different material types showed a significant color change (ΔE) at P < 0.001. Filtek exhibited the most significant color change, followed by Gradia and Palfique, with no significant differences between them. In addition, Different polishing techniques resulted in significant color changes (P < 0.001). The highest degree of color change was seen in the no-polishing group, followed by the 4-step and 1-step polishing groups, with negligible differences between each other. Also, Storage media had a significant effect on ΔE values. CONCLUSION: Appropriate finishing and polishing procedures can improve the color stability of bleach-shaded composite resins. Coffee has a deleterious effect on color; however, injectable flowable nanohybrid composites are more resistant to staining.


Asunto(s)
Óxido de Aluminio , Café , Color , Resinas Compuestas , Pulido Dental , Propiedades de Superficie , Resinas Compuestas/química , Pulido Dental/métodos , Óxido de Aluminio/química , Ensayo de Materiales , Espectrofotometría , Técnicas In Vitro , Humanos , Diamante/química , Nanocompuestos/química , Blanqueadores Dentales/química , Agua/química , Materiales Dentales/química , Factores de Tiempo
5.
BMC Oral Health ; 24(1): 651, 2024 Jun 03.
Artículo en Inglés | MEDLINE | ID: mdl-38831398

RESUMEN

BACKGROUND: Carious/Non-carious cervical lesions with gingival recessions may require both dental and periodontal reconstructive therapy, where flaps/grafts may be placed in contact with a dental filling material. Human Gingival Fibroblasts (HGF-1) response during the early phase of healing could vary according to the procedures employed to cure the dental composite. Moreover, oxygen diffusion into dental composite inhibits the polymerization reaction, creating an oxygen-inhibited layer (OIL) that presents residual unreacted monomers. The aim of this study was to assess the effect of different polishing techniques and OIL on HGF-1. METHODS: Composite discs polished with different techniques (diamond rubber, abrasive discs and tungsten carbide burr) were used. An additional not polished smooth group obtained with and without OIL was used as control. Samples were physically characterized through the analysis of their hydrophilicity and surface topography through contact angle measurement and SEM, respectively; afterwards the biologic response of HGF-1 when cultured on the different substrates was analyzed in terms of cytotoxicity and gene expression. RESULTS: The finishing systems caused alterations to the wettability, even if without a proportional relation towards the results of the proliferation essay, from which emerges a greater proliferation on surfaces polished with one-step diamond rubber and with abrasive discs as well as a direct effect of the glycerin layer, confirming that surface roughness can heavily influence the biological response of HGF-1. CONCLUSIONS: Surfaces wettability as well as cellular behavior seem to be affected by the selection of the finishing system used to lastly shape the restoration. Especially, the presence of OIL act as a negative factor in the regards of human gingival fibroblasts. The present study may provide the first clinical instruction regarding the best polishing system of composite material when the restoration is placed directly in contact with soft tissue cells. Understanding HGF-1 behavior can help identifying the polishing treatment for direct restoration of carious/non-carious cervical lesions associated with gingival recessions.


Asunto(s)
Resinas Compuestas , Pulido Dental , Fibroblastos , Encía , Propiedades de Superficie , Humanos , Encía/citología , Pulido Dental/métodos , Microscopía Electrónica de Rastreo , Proliferación Celular , Humectabilidad , Restauración Dental Permanente/métodos , Compuestos de Tungsteno/farmacología , Células Cultivadas
6.
Med Sci Monit ; 30: e944502, 2024 Jun 10.
Artículo en Inglés | MEDLINE | ID: mdl-38857196

RESUMEN

BACKGROUND Before insertion, chairside adjustment kits are heat sterilized for positioning and polishing dental restorations. This study aimed to evaluate the effects of 2 steam sterilization cycles on the efficacy of polishing highly translucent monolithic zirconia (HTMLZ) dental restoration material. MATERIAL AND METHODS 100 HTMLZ disc-shaped specimens were adjusted (grinding, finishing, polishing) with EVE Diacera kit. Two steam sterilization techniques [standard (Gp S), immediate/flash (Gp (F)] of CAK were further subgrouped based on number of sterilization cycles [cycle 1 (control), cycle 5, 10, 15, and 20 (experimental)] (n=10 each). Each subgroup accordingly was evaluated for average surface roughness (Ra) and root mean square roughness (Rq) using a profilometer. Mean and standard deviation of 5 subgroups were statistically analyzed using one-way ANOVA/post hoc Tukey's test. Scanning electron microscopy complemented Ra, Rq measurements. Statistical differences of P≤0.05 were considered significant. RESULTS HTMLZ specimens in both groups showed increased (Ra/Rq) values after repeated sterilization of EVE Diacera kit, with Gp F showing lesser increase than Gp S (20 cycles). Gp F at 10 cycles and Gp S at 15 cycles showed clinically unacceptable roughness threshold (0.25 µm). Differences between subgroups for Ra and Rq values were significant (P≤0.05) with less differences within groups observed in early cycles (1, 10). Results validate the manufacturer's recommendations of using flash sterilization/10 cycles for EVE Diacera kit. CONCLUSIONS Repeated sterilization reduces efficacy of chairside adjustment kit to produce smooth surfaces on HTMLZ. This study recommends flash sterilization to a maximum of 10 times to get the clinically acceptable results of Ra and Rq.


Asunto(s)
Materiales Dentales , Pulido Dental , Vapor , Esterilización , Propiedades de Superficie , Circonio , Esterilización/métodos , Humanos , Pulido Dental/métodos , Ensayo de Materiales/métodos , Restauración Dental Permanente/métodos , Microscopía Electrónica de Rastreo/métodos
7.
Dent Mater J ; 43(4): 485-494, 2024 Jul 31.
Artículo en Inglés | MEDLINE | ID: mdl-38825451

RESUMEN

Highly polished 3, 4, and 5 mol% yttria-stabilized zirconia and CAD/CAM composite resin samples were prepared, and the influence of surface roughness (Ra and Sa, 21 areas/group), wettability (contact angle and surface energy, 3 samples/group), and surface chemical composition (2 samples/group) on single-strain bacterial adhesion models (Porphyromonas gingivalis, Streptococcus oralis, Streptococcus sanguinis, Streptococcus gordonii, and Streptococcus mutans) were compared via fluorescent staining with graphical analysis (21 areas/group). Statistical analysis was performed using the Shapiro-Wilk test followed by one-way analysis of variance with Tukey's test or the Kruskal-Wallis test with Dunn's test (α=0.05) and linear regression. For dental zirconia with the same surface roughness, the yttria content did not significantly influence the initial bacterial adhesion. However, higher bacterial adhesion was detected for the composite resin owing to its high C, O, and Si contents. There was no correlation between surface energy and bacterial adhesion for any bacterial strain (p<0.005).


Asunto(s)
Adhesión Bacteriana , Resinas Compuestas , Materiales Dentales , Propiedades de Superficie , Circonio , Circonio/química , Resinas Compuestas/química , Materiales Dentales/química , Técnicas In Vitro , Itrio/química , Pulido Dental/métodos , Ensayo de Materiales , Streptococcus , Streptococcus mutans , Humectabilidad , Streptococcus gordonii/fisiología , Streptococcus sanguis , Porphyromonas gingivalis , Colorantes Fluorescentes
8.
J Dent ; 148: 105154, 2024 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-38942111

RESUMEN

OBJECTIVE: This study evaluated the clinical performance of Class II restorations made with flowable bulk-fill base versus conventional layering ORMOCER-based restorative material in a split-mouth randomized clinical trial. METHODS: Thirty patients received two class II restorations (n = 60) performed with different strategies. All preparations received the application of the universal self-etching adhesive system according to the manufacturer's recommendation, followed by the placement of a sectional matrix, wooden wedge, and separation ring. The first restoration was performed using 4 mm of flowable bulk-fill material covered by 2 mm of conventional viscosity restorative material (Bulk-fill technique). The second restoration was performed only with the conventional viscosity material, with a maximum of 2 mm thick increments, up to fill the cavity (Layering technique). After occlusal adjustment, the same polishing system was used for all restorations. Evaluations using the FDI criteria were conducted after 7 days, 12, and 24 months. Data were analyzed with the Fisher's Exact test (α=0.05). RESULTS: From 30 participants, 24 attended the 24-month recall, and 48 restorations were evaluated. All restorations received acceptable overall scores for esthetic and biological properties after this period, while only 6.66 % of the restorations exhibited unacceptable overall scores for the functional properties in both groups. No significant differences between the tested restorative materials and techniques were found for each FDI criterion assessed. The success rate after 2 years was 93.33 % for both groups. CONCLUSION: Both restorative materials exhibited good clinical performance for the parameters analyzed with no differences between them after 24-month follow-up. CLINICAL RELEVANCE: Flowable bulk-fill ORMOCER-based material is a suitable alternative for direct Class II restorations, providing good clinical outcomes and simplifying the restorative procedure. CLINICAL TRIAL REGISTRATION NUMBER: RBR-6mvp9w.


Asunto(s)
Resinas Compuestas , Materiales Dentales , Restauración Dental Permanente , Humanos , Restauración Dental Permanente/métodos , Restauración Dental Permanente/clasificación , Femenino , Masculino , Resinas Compuestas/química , Resinas Compuestas/uso terapéutico , Adulto , Persona de Mediana Edad , Materiales Dentales/química , Estética Dental , Propiedades de Superficie , Viscosidad , Cerámicas Modificadas Orgánicamente , Adulto Joven , Resultado del Tratamiento , Preparación de la Cavidad Dental/clasificación , Preparación de la Cavidad Dental/métodos , Caries Dental/terapia , Pulido Dental , Adaptación Marginal Dental
9.
Dent Mater ; 40(8): 1123-1127, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38824001

RESUMEN

OBJECTIVE: Achieving a strong bond between Polyetheretherketone (PEEK) and veneering composites is challenging due to PEEKs low surface energy. This study examined the effects of sandblasting and bonding on the shear bond strength (SBS) between veneering composite and pigmented PEEK, considering artificial aging. METHODS: Of three pigmented PEEK compounds (DC4420R, DC4450R, DC4470R; Evonic Operations GmbH, Marl, Germany), 40 specimens each were milled and polished up to 2500 grit. Prior to veneering, specimens were divided into 4 subgroups: Subgroup 1: Polishing; 2: Polishing + bonding; 3: Sandblasting; 4: Sandblasting + bonding. Sandblasting was performed using Al2O3. Adhesive was an agent containing MMA (Signum Universal Bond, Kulzer GmbH, Hanau, Germany). After veneering (Composite, Kulzer GmbH) the subgroups were divided into 2 subgroups. One subgroup was immersed in 37 °C warm distilled water for 24 h. The second subgroup was artificially aged by thermocycling (TCL) with 5000 cycles in distilled water (5 °C / 55 °C; 30 s). Surface roughness, water contact angles and failure modes were recorded. SBS was measured using a universal testing machine. RESULTS: Results demonstrated that the combination of sandblasting and bonding significantly improved the SBS compared to polishing alone. PEEK color did not significantly influence the SBS. Aging by TCL had a negative effect on the SBS. SIGNIFICANCE: Sandblasting and the use of an adhesive containing MMA were found to be effective in achieving satisfactory SBS between veneering composite and pigmented PEEK surfaces. These pretreatment methods demonstrate their potential for establishing durable and reliable bonding in clinical applications.


Asunto(s)
Benzofenonas , Resinas Compuestas , Recubrimiento Dental Adhesivo , Análisis del Estrés Dental , Coronas con Frente Estético , Cetonas , Ensayo de Materiales , Polietilenglicoles , Polímeros , Resistencia al Corte , Propiedades de Superficie , Cetonas/química , Resinas Compuestas/química , Polímeros/química , Polietilenglicoles/química , Pulido Dental , Grabado Dental/métodos , Óxido de Aluminio/química , Color
10.
J Dent ; 147: 105120, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38857647

RESUMEN

OBJECTIVES: To evaluate the wear resistance of three additively manufactured dental crown materials (NextDent C&B MFH, Saremco print CROWNTEC and Bego VarseoSmile Crown) under two environmental conditions (dry and artificial saliva), two loads (49 N and 70 N) and two surface treatments (polished and glazed). METHODS: A total of 120 specimens were divided into 24 groups and tested for wear under two loads (49 N and 70 N), surface treatment (polished or glazed), and environment (dry or submerged in artificial saliva). All samples underwent reciprocating wear testing at 1 Hz using a wear simulator, replicating 48 months of In Vivo conditions with a stainless-steel ball as the antagonist. The coefficient of friction (CoF), surface roughness, volumetric and vertical wear loss were measured and statistically analysed. Confocal microscopy assessed the surface properties of crown materials and the antagonists. RESULTS: The NextDent material demonstrated the most homogenous wear, with relatively low vertical and volumetric loss across all groups (p < 0.004). NextDent and Bego materials performed similarly in artificial saliva regardless of the load type (p > 1.000). The CoF remained below 0.3 for all groups. All groups exhibited significant increases in surface roughness after testing, however, this did not correlate with an increase in the CoF. Confocal analysis revealed material deformities due to load and notable scratch marks on the stainless-steel antagonists. CONCLUSION: It was found that all investigated addtively manufactured materials can be suggested for provisional use. Both vertical loss and volumetric loss results should be included for material evaluation. CoF and surface roughness should be implemented into wear evaluation. CLINICAL SIGNIFICANCE: This study highlights the practical value of additively manufactured dental crown materials, particularly for provisional restorations. However, their extended use requires careful consideration of individual patient needs, emphasising the need for judicious clinical application evaluation.


Asunto(s)
Coronas , Materiales Dentales , Alisadura de la Restauración Dental , Fricción , Ensayo de Materiales , Saliva Artificial , Propiedades de Superficie , Saliva Artificial/química , Materiales Dentales/química , Humanos , Pulido Dental , Acero Inoxidable/química , Microscopía Confocal , Análisis del Estrés Dental
11.
BMC Oral Health ; 24(1): 558, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38741081

RESUMEN

BACKGROUND: We investigated the efficacy of two different cold atmospheric pressure jet plasma devices (CAP09 and CAPmed) and an air polishing device with glycine powder (AP) either applied as monotherapies or combined therapies (AP + CAP09; AP + CAPmed), in microbial biofilm removal from discs with anodised titanium surface. METHODS: Discs covered with 7-day-old microbial biofilm were treated either with CAP09, CAPmed, AP, AP + CAP09 or AP + CAPmed and compared with negative and positive controls. Biofilm removal was assessed with flourescence and electron microscopy immediately after treatment and after 5 days of reincubation of the treated discs. RESULTS: Treatment with CAP09 or CAPmed did not lead to an effective biofilm removal, whereas treatment with AP detached the complete biofilm, which however regrew to baseline magnitude after 5 days of reincubation. Both combination therapies (AP + CAP09 and AP + CAPmed) achieved a complete biofilm removal immediately after cleaning. However, biofilm regrew after 5 days on 50% of the discs treated with the combination therapy. CONCLUSION: AP treatment alone can remove gross biofilm immediately from anodised titanium surfaces. However, it did not impede regrowth after 5 days, because microorganisms were probably hidden in holes and troughs, from which they could regrow, and which were inaccessible to AP. The combination of AP and plasma treatment probably removed or inactivated microorganisms also from these hard to access spots. These results were independent of the choice of plasma device.


Asunto(s)
Biopelículas , Implantes Dentales , Gases em Plasma , Propiedades de Superficie , Titanio , Biopelículas/efectos de los fármacos , Titanio/química , Implantes Dentales/microbiología , Pulido Dental/métodos , Glicina , Humanos , Técnicas In Vitro , Microscopía Electrónica de Rastreo , Níquel
12.
Am J Dent ; 37(2): 66-70, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704848

RESUMEN

PURPOSE: To evaluate the effect of different finishing and polishing systems on the surface roughness of a resin composite subjected to simulated saliva-, acid-, and enzyme-induced degradation. METHODS: 160 specimens (n= 40) were fabricated with Filtek Z350 XT nanofilled composite and analyzed for average surface roughness (Ra). The specimens were finished and polished using: AD - Al2O3-impreginated rubberized discs (medium, fine, and superfine grit, Sof-Lex); SD - silicon carbide and Al2O3-impregnated rubberized discs (coarse, medium and fine grit, Jiffy,); MB - 12- and 30-multiblade burs. The control group (CT) (n= 40) comprised specimens with a Mylar-strip-created surface. Specimens from each group were immersed in 1 mL of one of the degradation methods (n= 10): artificial saliva (ArS: pH 6.75), cariogenic challenge (CaC: pH 4.3), erosive challenge (ErC: 0.05M citric acid, pH 2.3) or enzymatic challenge (EzC: artificial saliva with 700 µg/mL of albumin, pH 6.75). The immersion period simulated a time frame of 180 days. Ra measurements were also performed at the post-polishing and post-degradation time points. The data were evaluated by three-way ANOVA for repeated measures and the Tukey tests. RESULTS: There was significant interaction between the finishing/polishing system and the degradation method (P= 0.001). AD presented the greatest smoothness, followed by SD. After degradation, CT, AD and SD groups became significantly rougher, but not the MB group, which presented no difference in roughness before or after degradation. CT and AD groups showed greater roughness in CaC, ErC and EzC than in ArS. The SD group showed no difference in roughness when the specimens were polished with CaC, EzC or ArS, but those treated with ErC had greater roughness. In the MB group, the lower roughness values were found after using CaC and EzC, while the higher values were found using ErC or ArS. CLINICAL SIGNIFICANCE: As far as degradation resistance of nanofilled composite to hydrolysis, bacterial and dietary acids and enzymatic reactions is concerned, restorations that had been finished and polished with Al2O3-impregnated discs had the smoothest surfaces.


Asunto(s)
Óxido de Aluminio , Resinas Compuestas , Pulido Dental , Saliva Artificial , Compuestos de Silicona , Propiedades de Superficie , Resinas Compuestas/química , Pulido Dental/métodos , Humanos , Saliva Artificial/química , Concentración de Iones de Hidrógeno , Óxido de Aluminio/química , Compuestos de Silicona/química , Compuestos Inorgánicos de Carbono/química , Ensayo de Materiales , Nanocompuestos/química , Ácido Cítrico/química , Saliva/enzimología , Saliva/metabolismo , Saliva/química , Erosión de los Dientes , Goma/química , Materiales Dentales/química
13.
Am J Dent ; 37(2): 101-105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704853

RESUMEN

PURPOSE: To evaluate the effect of toothbrushing with conventional and whitening dentifrices on the color difference (ΔE00), gloss (Δgloss), and surface roughness (SR) of stained stabilized zirconia with 5 mol% of yttrium oxide (5Y-TZP) after polishing or glazing. METHODS: Specimens were divided into four groups (n=20): C (control), S (staining), SG (staining and glazing) and SP (staining and polishing). 50,000 toothbrushing cycles were performed with conventional (n=10) and whitening (n= 10) dentifrice slurries. The ΔE00 and Δgloss were measured using a spectrophotometer and CIEDE2000 system while SR was measured by laser confocal microscope. The ΔE00 and Δgloss data were analyzed using 2-way ANOVA, and SR data were analyzed using the linear repeated measures model, with Bonferroni's complementary test (α= 0.05). RESULTS: The ΔE00 values were beyond the acceptability threshold and no differences were found among the groups. There was no difference among groups to Δgloss after toothbrushing with conventional dentifrice while SP presented the highest values of Δgloss after toothbrushing with whitening dentifrice. Conventional dentifrice decreased the SR of stained groups and whitening dentifrice decreased SR of S and SG. The toothbrushing with conventional and whitening dentifrices promoted color difference, but did not impair gloss and surface roughness of stained 5Y-TZP. CLINICAL SIGNIFICANCE: Monolithic zirconia has been routinely used for esthetic restorations, however the type of finishing procedures that is carried out on it must be taken into consideration, in addition to the fact that brushing can influence the color difference of the material as well as interfere with surface roughness and gloss.


Asunto(s)
Dentífricos , Propiedades de Superficie , Cepillado Dental , Circonio , Circonio/química , Dentífricos/uso terapéutico , Color , Blanqueadores Dentales/uso terapéutico , Pulido Dental/métodos , Itrio/química , Humanos , Ensayo de Materiales , Blanqueamiento de Dientes/métodos , Espectrofotometría , Microscopía Confocal
14.
BMC Oral Health ; 24(1): 609, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38796434

RESUMEN

BACKGROUND: High speed electric handpieces have recently been growing in popularity among dental professionals. Advantages include smoother surface preparation and increased cutting efficiency. AIM: The primary objective was to compare enamel surface roughness following resin cleanup after bracket debonding using highspeed air turbine versus electric handpiece. The secondary objective was to record the time needed for resin-clean up. METHOD: Forty deidentified freshly extracted human premolars were cleaned and sectioned at the cement-enamel junction. The crowns were embedded in acrylic blocks. Enamel surface roughness parameters (Ra, Rz, Rp and Rv) were measured using a stylus profilometer. Brackets were bonded using a light-cure orthodontic adhesive and stored in distilled water for 24 h. Following bracket debonding, the specimens were randomly divided into 2 groups: First group: resin clean-up was carried out using a 12-fluted carbide bur mounted on a high-speed air turbine; and second group: where an electric handpiece was used. Surface roughness parameters were measured following resin clean up and after polishing using pumice and a rubber cup. Time needed for resin clean-up was recorded. Differences in enamel surface roughness and time between groups were compared using repeated measures ANOVA and independent samples t-test, respectively at P ≤ 0.05. RESULTS: The electric handpiece groups showed significantly higher values for Ra, Rz and Rp both following resin cleanup and polishing. Time taken for resin cleanup was significantly longer for the electric handpiece group. CONCLUSION: Considering both surface roughness and time, electric handpiece do not seem to add greater effectiveness or efficiency to resin cleanup following orthodontic bracket debonding.


Asunto(s)
Desconsolidación Dental , Esmalte Dental , Equipo Dental de Alta Velocidad , Propiedades de Superficie , Humanos , Desconsolidación Dental/métodos , Técnicas In Vitro , Cementos de Resina/química , Soportes Ortodóncicos , Factores de Tiempo , Diente Premolar , Pulido Dental/métodos
15.
Clin Exp Dent Res ; 10(3): e884, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38798053

RESUMEN

OBJECTIVES: This study compared the effects of glazing versus polishing on mechanical, optical, and surface properties of zirconia ceramics with different translucencies. MATERIALS AND METHODS: In this in vitro study, 120 bar-shaped specimens (25 × 4 × 1.2 mm) were fabricated from three different types of zirconia with different translucencies (n = 40, DD Bio ZW, ZX2, and Cube X2). After sintering, each zirconia group was randomly divided into five subgroups of control (glazing), glazing + bur abrasion, glazing + bur abrasion + polishing with EVE Diacera® kit, glazing + bur abrasion + reglazing, and glazing + bur abrasion + polishing with EVE Diacera® kit + reglazing. The specimens underwent surface roughness, hardness, flexural strength, and translucency tests, as well as X-ray diffraction (XRD) and scanning electron microscopy (SEM) for assessment of surface topography. Data were analyzed by one-way analysis of variance, Tukey test, and Pearson test (α = .05). RESULTS: Flexural strength, surface hardness, and translucency were significantly correlated with zirconia type. ZW zirconia had significantly higher flexural strength and surface hardness and significantly lower translucency than Cube X2 and ZX2 (p < .001). Surface roughness had no significant correlation with zirconia type (p = .274). Polishing created the smoothest, and bur abrasion created the roughest surface (p < .001). Flexural strength and hardness in most experimental groups were significantly lower than in the control group (p < .001). Translucency was not significantly different in bur abrasion and polishing groups, compared with the control group; however, reglazing significantly increased the translucency (p < .001). SEM micrographs confirmed the surface roughness results. XRD showed monoclinic phase only in reglazed groups. CONCLUSION: Of different surface treatments, polishing improved the surface properties and caused the smallest change in mechanical properties of zirconia with different translucencies.


Asunto(s)
Cerámica , Pulido Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Circonio , Circonio/química , Pulido Dental/métodos , Cerámica/química , Dureza , Materiales Dentales/química , Resistencia Flexional , Difracción de Rayos X , Técnicas In Vitro
16.
J Dent ; 146: 105101, 2024 07.
Artículo en Inglés | MEDLINE | ID: mdl-38801940

RESUMEN

OBJECTIVE: To evaluate the effect of polishing and layering thickness on the wear resistance of 3D-printed occlusal splint materials. METHODS: Specimens with 3 different layer thicknesses (50, 75, 100 µm) were produced in the form of a disc 3 mm thick using V-Print splint resin on a 3D-printer with digital light processing technology. (n = 16 for each thickness) All specimens were washed and cured according to the manufacturer's instructions. Half of the specimens of each layer thickness were polished with silicon carbide papers. All specimens were subjected to 120.000 cycles of a chewing simulator for 2-body wear tests. Before and after the wear test, the specimens were scanned with a laser scanner, and the images were overlaid using a 3D analysis program and the volume loss was calculated. The wear patterns of the specimens were examined under a scanning electron microscope. Statistical evaluation was performed using a Shapiro-Wilk test, 2-way ANOVA, 1-way ANOVA, and Tukey post hoc test (α = 0.05). RESULTS: While polishing had a significant effect (p = 0.003) on the wear volume of the occlusal splints, layer thickness (p = 0.105) and their interaction between polishing and layer thickness (p = 0.620) did not significantly affect the wear volume. Regardless of the polishing, the lowest mean wear was observed for D50 (0.064 mm3), followed by D75 (0.078 mm3), and D100 (0.096 mm3). However, a significant difference was observed only between polished D50 and unpolished D100. CONCLUSION: The polished 3D-printed occlusal splint resin showed higher wear resistance than the unpolished one, regardless of the layer thickness. CLINICAL SIGNIFICANCE: Since different layer thicknesses of 50 µm and greater had no effect on the wear resistance of the material, a layer thickness of 100 µm may be preferred for faster printing. However, polishing occlusal splints may reduce the amount of wear and improve clinical performance.


Asunto(s)
Pulido Dental , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Ferulas Oclusales , Impresión Tridimensional , Propiedades de Superficie , Pulido Dental/métodos , Humanos , Compuestos Inorgánicos de Carbono/química , Compuestos de Silicona/química , Alisadura de la Restauración Dental , Rayos Láser , Materiales Dentales/química , Diseño Asistido por Computadora , Masticación/fisiología
17.
J Prosthet Dent ; 132(2): 466.e1-466.e9, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38797579

RESUMEN

STATEMENT OF PROBLEM: Three-dimensional (3D) printing enables the fast fabrication of definitive fixed dental prostheses (FDPs). However, data on the effects of surface treatments on their chemical and mechanical properties are lacking. PURPOSE: The purpose of this in vitro study was to examine the influence of different surface treatments on a 3D printed resin in comparison with 2 veneering composite resins. MATERIAL AND METHODS: A total of 288 specimens were manufactured from a 3D printed resin (VarseoSmile Crownplus) or veneering composite resins (GRADIA PLUS; VITA VM LC flow). Surfaces underwent varnishing, coating, polishing or remain untreated. Conversion rate (DC), surface roughness (SR), Martens parameter, flexural strength (FS), and 3-body wear (3BW) were determined (n=12). Statistical analysis was performed using Mann-Whitney-U, Kruskal-Wallis, and Spearman correlation tests (α=.05). RESULTS: After polishing, the 3D printed resin showed higher DC, SR, and 3BW but lower Martens parameters compared with veneering composite resins (P<.007). After goat hair brushing, the 3D printed resin showed lower FS than VITA-VCR (P=.043). For the 3D printed resin, goat hair brushing or GC-Varnish reduced SR, while VITA-Varnish showed the lowest 3BW (P<.045). For both veneering composite resins, goat hair brushing led to low SR and 3BW and high EIT and FS (P<.043). Silicone polishing led to low EIT of the 3D printed resin and low EIT and FS of GC-VCR (P<.009). Coating resulted in a lower EIT than the untreated surface and higher 3BW than GC-Varnish (P<.030). CONCLUSIONS: The 3D printed resin showed higher DC, SR, 3BW and lower HM, EIT, and FS values than the veneering composite resins. Polishing with a goat hair brush can be recommended for all tested materials. For the 3D printed resin, varnishing presents a promising alternative with regard to SR and 3BW. Silicone polishing and coating cannot be recommended.


Asunto(s)
Resinas Compuestas , Pulido Dental , Coronas con Frente Estético , Ensayo de Materiales , Impresión Tridimensional , Propiedades de Superficie , Resinas Compuestas/química , Pulido Dental/métodos , Materiales Dentales/química , Técnicas In Vitro , Resistencia Flexional
18.
Proc Inst Mech Eng H ; 238(7): 803-813, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38706301

RESUMEN

The aim of this study was to evaluate the effect of rotation frequency (rpm) of different polishing discs on the surface roughness of a nanohybrid resin composite material. 126 specimens were prepared in metal molds of 10 mm diameter and 2 mm depth using a nanohybrid resin composite material. The prepared specimens were kept in distilled water for 24 hours. Polishing treatments at 5k, 10k, 15k, and 20k rpm were applied to the nanohybrid resin composite material by grouping different brand polishing discs: Sof-Lex Contouring and Polishing Discs (3M Espe, USA) (3M Group), Optidisc (Kerr Corporation, USA) (Kerr Group), Super-Snap Rainbow Technique Kit (Shofu Dental, Japan) (Shofu Group), Finishing Disc (Bisco Dental, USA) (Bisco Group). The surface roughness was evaluated at three different points by atomic force microscopy for all specimens and scanning electron microscopy was used for visual assessment. Data were evaluated by Two Way ANOVA and Tukey's HSD Test. The mean surface roughness (Ra, µm) of all prepared samples showed significant differences (α = 0.05). According to Two-Way ANOVA, there is a statistically significant relationship between the rpm values and the discs. The 3M group showed the highest roughness value at all rpm speeds. Shofu group at 15k, 20k rpm, Bisco group at 10k, 15k, 20k rpm, the Kerr group at 15k, 20k rpm showed the lowest roughness value and had roughness close to the surfaces finished with a mylar strip. The smoothest surfaces were obtained at 15k rpm, even though polishing discs from different brands were used. It was also observed that 5k and 20k rpm polishing speeds can increase the surface roughness of the nanohybrid resin composite material.


Asunto(s)
Resinas Compuestas , Ensayo de Materiales , Propiedades de Superficie , Resinas Compuestas/química , Rotación , Pulido Dental
19.
Niger J Clin Pract ; 27(4): 496-503, 2024 Apr 01.
Artículo en Inglés | MEDLINE | ID: mdl-38679773

RESUMEN

BACKGROUND: Monolithic zirconia restorations can be produced from self-colored or uncolored blocks. The coloring procedure of uncolored blocks and surface treatments may affect the appearance of the restoration. AIM: The purpose of this study is to evaluate the effect of liquid coloring and surface treatments on optical properties of translucent monolithic zirconia. METHODS: All specimens were cut from zirconia blocks with a thickness of 1 mm. Specimens were dipped in the coloring liquids for 3 min, 5 min, and 7 min and then divided into groups of 10 specimens for surface treatments. Glaze and mechanical polishing were applied, and the color of the specimens was measured under the D65 lighting condition with a spectrophotometer device. Color values obtained from the CIE Lab formula and the translucency parameter (TP), opalescence parameter (OP), and contrast ratio (CR) were calculated. The normality of the data was confirmed with the Shapiro-Wilk test. A three-way analysis of variance (ANOVA) was used to assess the effect of dipping time, liquid shade, and surface treatments. RESULTS: The effect of liquid shade and dipping time on the TP, OP, and CR parameters were statistically significant, and the TP values were reduced with the application of coloring liquid. Mechanical polishing groups had higher OP values and lower TP values than glazed groups. CONCLUSION: In cases where high translucency is required, it may be advisable to use self-colored blocks and apply glaze as a surface treatment to achieve the desired optical properties.


Asunto(s)
Propiedades de Superficie , Circonio , Circonio/química , Humanos , Ensayo de Materiales , Color , Espectrofotometría , Materiales Dentales/química , Factores de Tiempo , Colorantes , Pulido Dental/métodos
20.
J Dent ; 144: 104918, 2024 05.
Artículo en Inglés | MEDLINE | ID: mdl-38461887

RESUMEN

OBJECTIVE: To determine the effect of airborne particle abrasion (APA) on micro-tensile bond strength (µTBS) to dentin using different air-abrasion/polishing powders. METHODS: The bonding effectiveness of G2 Bond Universal (G2B), used in etch-and-rinse (E&R) and self-etch mode (SE), was tested on bur-cut dentin and dentin air abraded/polished using six different powders (aluminum oxide 29 µm (AO29) and 53 µm (AO53), aluminum trihydroxide (AT), sodium bicarbonate (SB), sodium bicarbonate soft (SBsoft) and bioactive glass (BG); Velopex). Adhesive-composite resin specimens were immersed in distilled water at 37 °C for one week and cut into microspecimens. Half of the specimens were subjected to 50,000 thermocycles (aged). Immediate and aged µTBS to dentin were measured. Statistical analysis was performed using linear mixed-effects (LME) modeling (p < 0.05). RESULTS: Comparing the aged bond strengths to air-abraded/polished dentin with bur-cut dentin, pretreatment with SB and SBsoft in combination with G2B used in E&R mode, and BG air polishing in combination with both application modes (E&R, SE), resulted in a significantly higher bond strength. Dentin bond strength was only significantly lower when air abraded with AO29 and using G2B in SE mode. Aging did not significantly influence bond strength for both application modes (E&R, SE), except for AO29 and AT-treated dentin, where bond strengths decrea sed significantly using G2B in SE mode. In general, G2B reached significantly higher bond strengths on air-abraded/polished dentin in E&R mode than in SE mode. CONCLUSION: Air-abrasion/polishing did not impair dentin bond strength using G2B, except when dentin was air abraded with AO29 and using G2B in SE mode. Air polishing positively influenced the bond strength to dentin in specific groups. CLINICAL SIGNIFICANCE: APA is safe concerning bonding to dentin. The E&R application mode is preferred using G2B as adhesive on air-abraded/polished dentin. Air polishing with BG positively influenced dentin bond strength for both application methods.


Asunto(s)
Abrasión Dental por Aire , Resinas Compuestas , Recubrimiento Dental Adhesivo , Recubrimientos Dentinarios , Dentina , Ensayo de Materiales , Cementos de Resina , Propiedades de Superficie , Resistencia a la Tracción , Recubrimiento Dental Adhesivo/métodos , Humanos , Resinas Compuestas/química , Recubrimientos Dentinarios/química , Cementos de Resina/química , Análisis del Estrés Dental , Grabado Ácido Dental/métodos , Pulido Dental/métodos , Estrés Mecánico , Materiales Dentales/química , Polvos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...