Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 257
Filtrar
1.
Radiat Prot Dosimetry ; 200(11-12): 1216-1219, 2024 Jul 17.
Artículo en Inglés | MEDLINE | ID: mdl-39016518

RESUMEN

Latent fingerprint developed at the site of crime is considered as crucial physical evidence in forensic investigation. The mixed metal oxides (MXOY, M = Ba, Zn, Al, Ce) nanophosphor was synthesised by irradiating the precursor solution with 60Co gamma radiation followed by solution combustion method. The structural, morphological, optical characteristics and fingerprint imaging were studied using X-ray diffraction (XRD), scanning electron microscopy, UV-visible spectroscopy and powder dusting method, respectively. The XRD results revealed that the average crystallite size is found to be 30 nm with the estimated bandgap of 3.18 eV. The broadband UV exited luminescence of the phosphors was observed at λMax = 330 nm. The PL spectrum shows three emission bands at 432, 444 and 460 nm that corresponds to blue regions, suggesting that the synthesised nanophosphor is a potential luminous material for latent fingerprinting and luminescent devices.


Asunto(s)
Dermatoglifia , Óxidos , Óxidos/química , Humanos , Cerio/química , Rayos gamma , Difracción de Rayos X , Zinc/química , Aluminio/química , Nanopartículas del Metal/química , Radioisótopos de Cobalto/análisis , Microscopía Electrónica de Rastreo
2.
Forensic Sci Int ; 354: 111887, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38007870

RESUMEN

Two commercially available portable Rapid DNA instruments were evaluated for their ability to process 1 µL and 10 µL saliva samples deposited on metal and plastic surfaces and contaminated with surrogates of cesium (Cs)-137, strontium (Sr)-90 and cobalt (Co)-60; radioactive materials potentially released during a nuclear weapon accident or a radiological dispersal device detonation. A comparable success rate was noted for both Rapid DNA instruments when considering the number of complete and balanced DNA profiles, the number of profiles with a minimum of 10 autosomal STR loci (out of 23 [FlexPlex™ 27] or 21 [GlobalFiler™ Express]), and the possibility to search a national DNA database in Canada and the United States. Cobalt had an adverse impact on the quality of the megaplex short tandem repeat (STR) DNA profiles derived on each instrument for two of the three contamination levels tested in this study, i.e., 0.05 M and 0.1 M as reflected by a reduced number of detected alleles and decreased profile peak heights. Strontium exhibited some adverse effect on the Rapid DNA results when used at the highest contamination level (0.1 M) whereas cesium had none. No new artifacts were observed in the Rapid DNA profiles of samples spiked with the non-radiogenic surrogates. Importantly, in the context of a radiological/nuclear (RN) event, the ANDE™ 6C offers the possibility to dispose of all radioactive materials associated with contaminated samples quickly using a chip on which all steps of the Rapid DNA process are performed whereas the RapidHIT™ ID accumulates radioactive materials for many days before disposal. An individual handling 25 samples in a week (5 per day) on the RapidHIT™ ID at a 30.5 cm distance with a 5 min exposure to the radioactive source estimated at every run would exceed the 0.042 µSv/5 min limit with gamma dose rates for Cs at 0.13 mSv and for Co at 3.8 mSv. Beta dose rates calculated for the surrogate isotopes at the three concentrations tested were also above the recommended radiation exposure limit of 1 mSv/yr (0.042 µSv/5 min). Various potential mechanisms of action behind the interference noted for Sr and Co at high concentrations are presented. These elements may play a role in the steps prior to PCR (at the DNA molecule by binding to bases or to phosphate groups), during PCR (at the DNA polymerase as cofactors for catalytic sites), or even during amplified DNA fragment detection (as fluorescence quenchers).


Asunto(s)
Dermatoglifia del ADN , Terrorismo , Dermatoglifia del ADN/métodos , Reacción en Cadena de la Polimerasa , Repeticiones de Microsatélite , Mucosa Bucal/química , ADN/análisis , Radioisótopos de Cobalto/análisis , Radioisótopos de Cesio/análisis , Radioisótopos de Estroncio/análisis
3.
Appl Radiat Isot ; 175: 109824, 2021 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-34139667

RESUMEN

CDC designed a rapid HPGe Bioassay Method for 137Cs, 60Co, and 192Ir that is suitable for a public health response to a radiological incident where people may ingest or inhale radionuclides. The method uses a short count time, small sample volume, and a large volume detector and well size. It measures a patient's urine sample collected post-incident. The levels of concern are directly related to the Clinical Decision Guide levels recommended in the National Council of Radiation Protection 161.


Asunto(s)
Bioensayo/métodos , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Radioisótopos de Iridio/análisis , Radioisótopos de Cesio/orina , Radioisótopos de Cobalto/orina , Humanos , Radioisótopos de Iridio/orina , Monitoreo de Radiación/métodos , Espectrometría gamma/métodos
4.
Health Phys ; 119(6): 772-775, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32897985

RESUMEN

Operational practices in nuclear power utilities often restrict job assignments for workers with internal contamination due to the difficulty of monitoring for new intakes and strict radioactive material controls. However, restriction of job assignments for an extended period (i.e., months to years) may be too conservative. An industry consensus on guidance in these conditions would be helpful for Radiation Safety Officers (RSOs) to allow long term contaminated workers to have less work restrictions.


Asunto(s)
Radioisótopos de Cobalto/análisis , Empleo , Exposición por Inhalación/análisis , Enfermedades Profesionales/prevención & control , Exposición Profesional/análisis , Guías de Práctica Clínica como Asunto/normas , Monitoreo de Radiación/normas , Descontaminación , Humanos , Administración de la Seguridad
5.
Phys Med Biol ; 65(9): 095011, 2020 05 07.
Artículo en Inglés | MEDLINE | ID: mdl-32182598

RESUMEN

The IAEA is currently coordinating a multi-year project to update the TRS-398 Code of Practice for the dosimetry of external beam radiotherapy based on standards of absorbed dose to water. One major aspect of the project is the determination of new beam quality correction factors, k Q , for megavoltage photon beams consistent with developments in radiotherapy dosimetry and technology since the publication of TRS-398 in 2000. Specifically, all values must be based on, or consistent with, the key data of ICRU Report 90. Data sets obtained from Monte Carlo (MC) calculations by advanced users and measurements at primary standards laboratories have been compiled for 23 cylindrical ionization chamber types, consisting of 725 MC-calculated and 179 experimental data points. These have been used to derive consensus k Q values as a function of the beam quality index TPR20,10 with a combined standard uncertainty of 0.6%. Mean values of MC-derived chamber-specific [Formula: see text] factors for cylindrical and plane-parallel chamber types in 60Co beams have also been obtained with an estimated uncertainty of 0.4%.


Asunto(s)
Radioisótopos de Cobalto/análisis , Método de Montecarlo , Fotones/uso terapéutico , Radiometría/métodos , Radiometría/normas , Consenso , Humanos , Planificación de la Radioterapia Asistida por Computador , Efectividad Biológica Relativa , Incertidumbre
6.
J Radiol Prot ; 40(2): N17-N21, 2020 06.
Artículo en Inglés | MEDLINE | ID: mdl-32187020

RESUMEN

As a by-product of another measurement, ratios of the single-escape (SE) and double-escape (DE) efficiencies relative to the full-energy-peak efficiency (FE) have been measured for two HPGe detectors for 60Co. For a 2.5-cm-thick 95 cm3 crystal the results were SE/FE = 0.000 48 ± 0.000 20 and 0.003 25 ± 0.000 24 for 1173 and 1332 keV gamma-rays, respectively, and DE/FE = 0.000 90 ± 0.000 17 and 0.003 41 ± 0.000 11 for 1173 and 1332 keV, respectively. For a 3.0-cm-thick 84 cm3 crystal the results were SE/FE = 0.000 67 ± 0.000 32 and 0.003 79 ± 0.000 27 for 1173 and 1332 keV respectively, and DE/FE = 0.001 05 ± 0.000 28 and 0.004 29 ± 0.000 16 for 1173 and 1332 keV, respectively. These measurements may be of relevance in connection with Monte Carlo calculations of HPGe detector efficiencies, and may also suggest a path towards improved atomic cross-section measurements.


Asunto(s)
Radioisótopos de Cobalto/análisis , Espectrometría gamma/instrumentación , Diseño de Equipo , Germanio , Método de Montecarlo
7.
Phys Med Biol ; 65(5): 055015, 2020 03 06.
Artículo en Inglés | MEDLINE | ID: mdl-31962306

RESUMEN

To provide Monte Carlo calculated beam quality correction factors (k Q ) for monoenergetic proton beams using [Formula: see text], a toolkit based on the Monte Carlo code [Formula: see text]. Monte Carlo simulations of six plane-parallel and four cylindrical ionization chambers were carried out. The latest ICRU 90 recommendations on key data for ionizing-radiation dosimetry were used to calculate the electronic stopping powers and to select the mean energy necessary to create an ion pair in air ([Formula: see text]). [Formula: see text] factors were calculated for a 60Co spectrum at a depth of 5 g cm-2. f  Q factors and [Formula: see text] ratios as well as k Q factors were calculated at the entrance region of monoenergetic proton beams with energies between 60 MeV and 250 MeV. Additionally, perturbation correction factors for the Exradin A1SL ionization chamber at an energy of 250 MeV were calculated. [Formula: see text] factors agreed within 0.7% or better, f  Q factors within 1.7% or better and [Formula: see text] ratios within 2.2% or better with Monte Carlo calculated values provided in the literature. Furthermore, k Q factors calculated in this work were found to agree within 1% or better with experimentally determined k Q factors provided in the literature, with only two exceptions with deviations of 1.4% and 2.4%. The total perturbation correction factor for the Exradin A1SL chamber was 0.969(7) and hence significantly different than unity in contrast to the assumption from the IAEA TRS-398 code of practice (CoP). [Formula: see text] can be used to calculate k Q factors in clinical proton beams. k Q factors for six plane-parallel and four cylindrical ionization chambers were calculated and provided for the upcoming update of the IAEA TRS-398 CoP.


Asunto(s)
Algoritmos , Radioisótopos de Cobalto/análisis , Método de Montecarlo , Fantasmas de Imagen , Protones , Radiación Ionizante , Radiometría/métodos , Humanos , Dosis de Radiación , Radiometría/instrumentación , Efectividad Biológica Relativa
8.
Probl Radiac Med Radiobiol ; 24: 131-149, 2019 Dec.
Artículo en Inglés, Ucraniano | MEDLINE | ID: mdl-31841463

RESUMEN

OBJECTIVE: To assess an impact of the Rivne Nuclear Power Plant (RNPP) activity on the control area (CA) environ- ment according to environmental and radiation monitoring data over time of 2011-2017 as a component of the radiation safety system. MATERIALS AND METHODS: Review of geographical and natural features of the territory of the «Rivne NPP¼ manufac- turing facility was carried out to assess its CA environment. Assessment of environmental and radiation situation of the CA was carried out according to the data of RNPP monitoring systems and a number of state institutions of Rivne oblast over time of 2011-2017. Opinion of the CA population about the RNPP environmental impact was studied. The sampled population of respondents was calculated based on the total population living in CA. The sampling error no more that 7.0%. Data from sociological survey of population were calculated using the statistical programs. RESULTS: The radiation impact of RNPP on environment is related to emissions and discharges of radioactive sub- stances generated in the production cycle. Over time the total index of radionuclide discharge to the Styr River since 2011 is of a marked downward trend from 2.11 % to 0.18 %. The maximum concentrations of 60Co and 137Cs radionuclides at the three sampling points along the Styr River over time of 2011-2016 were about one thousandth of a percent, and of 131I - one hundredth of a permissible value according to the Radiation Safety Standards of Ukraine (RSSU). Emissions of inert radioactive gases and long-lived nuclides into the atmosphere were less than 0.2 % and iodine emissions were 0.01 % to the emission limit. Average radionuclide concentrations in the natural air of the RNPP CA settlements did not exceed the admissible concentration limit (ACL). Concentrations of chem- ical pollutants in discharges of the RNPP to the Styr River over time of 2012-2017 did not exceed the ACL. Integral wastewaters of municipal enterprises of the CA and RNPP result in an increased index of biochemical oxygen uti- lization and ammonium salt content in the Styr River, exceeding the ACL in fishery reservoir water. No exceedance of ACL of repugnant substances in the open air of settlements was observed regarding the pollutants under study. According to population survey the radiation contamination of territories as a result of the ChNPP accident and RNPP activities, which cause anxiety, are the key factors determining an environmental situation at the place of residence. The correlation coefficients between anxiety index and public estimates of environmental situation are established. CONCLUSIONS: Content of radionuclides in emissions and discharges generated in the RNPP production cycle under everyday conditions does not exceed the allowed RSSU-97 values. The combined discharges of collective enterpri- ses and RNPP are the main sources of chemical pollution of surface waters in CA. There is a higher correlation coef- ficient between the anxiety and somatization rates and environmental sphere parameter in rural population com- pared to urban one. The combined effect of environmental, radiation and psychological factors on the RNPP CA population makes the health studies necessary in the latter.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Plantas de Energía Nuclear , Exposición a la Radiación/análisis , Monitoreo de Radiación/métodos , Contaminantes Radiactivos del Agua/análisis , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Humanos , Radioisótopos de Yodo/análisis , Ríos/química , Ucrania
9.
Radiat Prot Dosimetry ; 187(3): 345-352, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31504965

RESUMEN

In 2016, the EURADOS working group 12 started a project to gather reliable data concerning the behavior of active personal dosemeters (APDs) used by European hospitals in standardized pulsed and hospital fields. This paper concentrates on the tests that deal with the dose rate dependence of APDs in laboratory tests. The dependence on the dose rate was determined for 10 dosemeter types with continuous radiation of a 60Co source and pulsed radiation of the reference radiation facility of Physikalisch-Technische Bundesanstalt. Furthermore, irradiations were done with continuous radiation of a 137Cs source of the Karlsruher Institute of Technology and with continuous X-rays of the two radiation qualites in radiation beams emerging from the X-ray source assembly, RQR5 and RQR8, of Nofer Institute of Occupational Medicine. For the first time, APDs have been systematically investigated under laboratory conditions in a pulsed reference fields according to ISO/TS 18090-1 and the experience gained by these test procedures will be included in the new IEC/TS 63050.


Asunto(s)
Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Laboratorios/normas , Exposición Profesional/análisis , Exposición Profesional/prevención & control , Monitoreo de Radiación/instrumentación , Protección Radiológica/métodos , Humanos , Equipos de Seguridad , Dosis de Radiación , Monitoreo de Radiación/normas , Rayos X
10.
Chemosphere ; 232: 87-95, 2019 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-31152907

RESUMEN

The removal of Co, Sr and Cs ions form simulated radioactive wastewater using forward osmosis (FO) process was investigated. The effect of various factors on nuclide transport was examined, including membrane orientation, NaCl concentration, flow velocity, and the main factors were identified by correlation analysis. The mechanisms of nuclides transfer through membrane were explored. The results indicated that the active layer facing draw solution (AL-DS) had higher nuclide flux than AL-FS. At AL-FS mode, the highest flux of Co, Sr and Cs were only 1.54, 10.22 and 15.63 mg m-2 h-1 respectively by cellulose triacetate with embedded polyester screen support (CTA-ES) membrane. At AL-DS mode, the flux of Co and Cs increased when NaCl concentration and flow velocity increased. Convection, diffusion and electrostatic interactions were found to influence the nuclide transport all together. The Pearson correlation and partial correlation analysis identified that the diffusion coefficient of nuclides and reverse NaCl flux were the most important factors affecting nuclide flux through cellulose triacetate membrane. The water flux, NaCl concentration, flow velocity and partition coefficient were not the main affecting factors for nuclide flux.


Asunto(s)
Eliminación de Residuos Líquidos/métodos , Contaminantes Radiactivos del Agua/análisis , Celulosa/análogos & derivados , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Membranas Artificiales , Ósmosis , Cloruro de Sodio , Radioisótopos de Estroncio/análisis , Aguas Residuales , Agua , Purificación del Agua/métodos
11.
Radiat Prot Dosimetry ; 186(4): 524-529, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-31038688

RESUMEN

The intercomparison test is a quality assurance activity performed for internal dose assessment. In Korea, the intercomparison test on internal dose assessment was carried out for nuclear facilities in May 2018. The test involved four nuclear facilities in Korea, and seven exposure scenarios were applied. These scenarios cover the intake of 131I, a uranium mixture, 60Co and tritium under various conditions. This paper only reviews the participant results of three scenarios pertinent to the operation of nuclear power plants and adopts the statistical evaluation method, used in international intercomparison tests, to determine the significance values of the results. Although no outliers were established in the test, improvements in the internal dose assessment procedure were derived. These included the selection of intake time, selection of lung absorption type according to the chemical form and consideration of the contribution of previous intake.


Asunto(s)
Contaminantes Radiactivos del Aire/análisis , Radioisótopos de Cobalto/análisis , Radioisótopos de Yodo/análisis , Exposición Profesional/análisis , Protección Radiológica/métodos , Medición de Riesgo/normas , Tritio/análisis , Carga Corporal (Radioterapia) , Humanos , Plantas de Energía Nuclear , Dosis de Radiación , Monitoreo de Radiación/métodos
13.
Radiat Prot Dosimetry ; 186(2-3): 235-238, 2019 Dec 31.
Artículo en Inglés | MEDLINE | ID: mdl-32123913

RESUMEN

The primary standard for air kerma of the Slovak Institute of Metrology (SMU) as a part of national standard of dosimetric quantities of gamma radiation NE028/02, based on cylindrical graphite walled cavity ionization chamber was established in 2002 for the 60Co gamma ray beams. Since then the main role of SMU was to continuously maintain, develop and refurbish the standard with related accessory to ensure international equivalence. Since 2002, a re-evaluation of the active volume of the ionizing chamber, correction factors, the key data, due to adoption of ICRU Report 90(1), and changes of the calibrations methods and corrections of the equipment were made to obtain improved parameters. The range was extended for 137Cs gamma ray beams and key comparisons with the Bureau International des Poids et Mesures (BIPM) were performed. ICRU Report 90(1) implementation led to a decrease of the Gray of -0.84% for 60Co and -0.80% for 137Cs.


Asunto(s)
Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Rayos gamma , Radiometría/instrumentación , Aire , Algoritmos , Calibración , Grafito , Dosis de Radiación , Radiometría/métodos , Eslovaquia
14.
Sci Total Environ ; 654: 1-9, 2019 Mar 01.
Artículo en Inglés | MEDLINE | ID: mdl-30428409

RESUMEN

Soil transport on fully vegetated land surfaces is typically detachment limited. Rates of soil and nutrient transport, and ultimately long-term landscape evolution, are controlled by processes that supply soil material for entrainment and transport. Despite their on-going nature, many such processes operate at low rates and have not been subject to detailed investigation. We present preliminary findings from a prototype tracing approach to quantify one such process; namely to determine the relative mobility of sediment from earthworm casts on a fully vegetated hillslope surface. A 0.6 ∗ 0.5 m bounded area of pasture was prepared and fifteen intact earthworm casts representing 203 g of soil were labelled with an estimated 216 Bq of caesium-134 (134Cs) activity and evenly distributed across the upslope half of the plot, 0.3-0.6 m from the downslope outlet. A further 15 intact casts representing 190.7 g of soil were labelled with 224 Bq of cobalt-60 (60Co) activity and distributed between 0.3 and 0.0 m from the same outlet. All labelled casts were exposed to natural weather events over 76 days, during which time 186.3 mm of rainfall generated 16 runoff samples. A mass balance was used to partition labelled sediment from the unlabelled material. A total of 27.17 g of 60Co-labelled casts, equivalent to 14.2% of the original mass deployed, was recovered from a distance of ≤0.3 m from their original locations. In contrast, 8.77 g of 134Cs-labelled casts, equivalent to 4.3% of the original mass deployed, was recovered from a distance ≥0.3 m from their original locations. Some runoff-derived samples recorded an over-enrichment of radionuclide material, which suggests that intact casts may sorb more material than the original assumption predicts. Ways in which sorption can be more accurately quantified to improve the accuracy of the tracing approach are outlined.


Asunto(s)
Monitoreo del Ambiente/métodos , Sedimentos Geológicos/química , Oligoquetos/química , Contaminantes del Suelo/análisis , Suelo/química , Animales , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Fenómenos Geológicos
15.
Radiat Prot Dosimetry ; 185(1): 67-73, 2019 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-30544246

RESUMEN

The majority of the radiation accidents with early acute clinical effects were associated with the orphan sources used in industrial and medical facilities. These accidents involved members of general public, who were entirely unaware of the exposure to the radiation. In such situations, the exposure commonly occurs when the source is in contact with a body of a victim, primarily located in pockets of clothing or in hands. In this research, the average absorbed doses in internal organs, skin and tissues close to the source were assessed using the phantom modeling of contact human exposure by the sealed 192Ir, 137Cs and 60Co gamma sources. The results allow estimating the RBE-weighted absorbed dose values in organs and tissues to assess the possibility and severity of deterministic medical effects caused by the exposure and to compare them with the reference levels established by IAEA for performing the protective and medical actions.


Asunto(s)
Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Radioisótopos de Iridio/análisis , Especificidad de Órganos/efectos de la radiación , Fantasmas de Imagen , Exposición a la Radiación/análisis , Medición de Riesgo/métodos , Rayos gamma , Humanos , Método de Montecarlo , Dosis de Radiación , Protección Radiológica/normas , Liberación de Radiactividad Peligrosa , Estándares de Referencia , Efectividad Biológica Relativa
16.
J Control Release ; 291: 11-25, 2018 12 10.
Artículo en Inglés | MEDLINE | ID: mdl-30291986

RESUMEN

BACKGROUND AND MOTIVATION: While small molecules can be used in cancer diagnosis there is a need for imageable diagnostic NanoParticles (NPs) that act as surrogates for the therapeutic NPs. Many NPs are composed of hydrophobic materials so the challenge is to formulate hydrophobic imaging agents. To develop individualized medical treatments based on NP, a first step should be the selection of patients who are likely responders to the treatment as judged by imaging tumor accumulation of NPs. This requires NPs with the same size and structure as the subsequent therapeutic NPs but labelled with a long-lived radionuclide. Cobalt isotopes are good candidates for NP labelling since 55Co has half-life of 17.5 h and positron energy of 570 keV while 57Co (t1/2 271.6 d) is an isotope suited for preclinical single photon emission tomography (SPECT) to visualize biodistribution and pharmacokinetics of NPs. We used the hydrophobic octaethyl porphyrin (OEP) to chelate cobalt and to encapsulate it inside hydrophobic liquid NPs (LNPs). We hypothesized that at least two additional hydrophobic axial ligands (oleylamine, OA) must be provided to the OEP-Co complex in order to encapsulate and retain Co inside LNP. RESULTS: 1. Cobalt chelation by OEP and OA. The association constant of cobalt to OEP was 2.49 × 105 M-1 and the formation of the hexacoordinate complex OEP-Co-4OA was measured by spectroscopy. 2. NP formulation and characterization: LNPs were prepared by the fast ethanol injection method and were composed of a liquid core (triolein) surrounded by a lipid monolayer (DSPC:Cholesterol:DSPE-PEG2000). The size of the LNPs loaded with the cobalt complex was 40 ±â€¯5 nm, 3. Encapsulation of OEP-Co-OA: The loading capacity of OEP-Co-OA in LNP was 5 mol%. 4. Retention of OEP-57Co-4OA complex in the LNPs: the positive effect of the OA ligands was demonstrated on the stability of the OEP-57Co-4OA complex, providing a half-life for retention in PBS of 170 h (7 days) while in the absence of the axial OA ligands was only 22 h. 5 Biodistribution Study: the in vivo biodistribution of LNP was studied in AR42J pancreatic tumor-bearing mice. The estimated half-life of LNPs in blood was about 7.2 h. Remarkably, the accumulation of LNPs in the tumor was as high as 9.4% ID/g 24 h after injection with a doubling time for tumor accumulation of 3.22 h. The most important result was that the nanoparticles could indeed accumulate in the AR42J tumors up to levels greater than those of other NPs previously measured in the same tumor model, and at about half the values reported for the molecular agent 57Co-DOTATATE. CONCLUSIONS: The additional hydrophobic chelator OA was indeed needed to obtain a stable octahedral OEP-Co-4OA. Cobalt was actually well-retained inside LNP in the OEP-Co-4OA complex. The method described in the present work for the core-labelling of LNPs with cobalt is now ready for labeling of NPs with 55Co, or indeed other hexadentate radionuclides of interest for preclinical in vivo PET-imaging and radio-therapeutics.


Asunto(s)
Aminas/análisis , Quelantes/análisis , Radioisótopos de Cobalto/análisis , Nanopartículas/análisis , Neoplasias/diagnóstico por imagen , Porfirinas/análisis , Tomografía Computarizada de Emisión de Fotón Único/métodos , Aminas/farmacocinética , Animales , Quelantes/farmacocinética , Radioisótopos de Cobalto/farmacocinética , Interacciones Hidrofóbicas e Hidrofílicas , Masculino , Ratones , Ratones Endogámicos NOD , Ratones SCID , Porfirinas/farmacocinética , Distribución Tisular
17.
J Environ Radioact ; 193-194: 57-67, 2018 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-30195154

RESUMEN

This paper summarizes the results of the decontamination of the infrastructure materials concrete, limestone, brick and asphalt contaminated with 60Co, 85Sr, 137Cs and 241Am. The paper focuses on the effect of differences in substrate properties and of the pH of the radionuclide solution used for surface contamination on adsorption or ion exchange of the radionuclides and how these factors affect the decontamination effectiveness. A six-component chemical formulation was used and a process effectiveness of up to 76% was obtained depending on the substrate and radionuclide. Asphalt was the easiest material to decontaminate because of its more hydrophobic nature. Concrete and limestone (and to some extent brick) were less effectively decontaminated as their porous surfaces allowed penetration of radionuclides into water-filled pores in the substrate facilitating adsorption or ion exchange and making them difficult to remove. Brick was the most difficult material to decontaminate because the major component of brick is clay which retains most mono- and divalent ions. The removal of 60Co, 85Sr and 137Cs from the surfaces of concrete, limestone and brick increased when the pH of the radionuclide solutions was moderately acidic to neutral compared to when they were highly acidic. The variability in the test results was similar to that observed in other studies using other decontamination methods, attributed to the inhomogeneity of the substrates used and considered representative of real infrastructure materials.


Asunto(s)
Americio/análisis , Radioisótopos de Cesio/análisis , Radioisótopos de Cobalto/análisis , Materiales de Construcción/análisis , Descontaminación/métodos , Contaminantes Radiactivos/análisis , Radioisótopos de Estroncio/análisis , Adsorción , Intercambio Iónico
18.
J Environ Radioact ; 192: 376-384, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30048900

RESUMEN

The uptake and depuration kinetics of dissolved 109Cd, 57Co and 134Cs were determined experimentally in the European flat oyster Ostrea edulis (Linnaeus, 1758) under different pH conditions (i.e., 8.1, 7.8 and 7.5) for 59 days. Uptake and depuration rates were variable within these elements; no effects were observed under different pH conditions for the uptake biokinetics of 109Cd and 57Co and depuration of 109Cd and 134Cs in oyster. The uptake and depuration rate constants of 134Cs differed during the exposure phase between treatments, while the steady state concentration factors (CFss) were similar. The resulting Cs activity that was purged during short- and long-term depuration phases differed, while the remaining activities after thirty-nine days depuration phase (RA39d) were similar. Co-57 depuration was affected by pCO2 conditions: RA39d were found to be significantly higher in oysters reared in normocapnia (pCO2 = 350 µatm) compared to high pCO2 conditions. Co-57 tissue distribution did not differ among the variable pCO2 conditions, while 109Cd and 134Cs accumulated in soft tissue of oysters were found to be higher under the highest pCO2. Additionally, Cd, Co and Cs were stored differently in various compartments of the oyster cells, i.e. cellular debris, metal-rich granules (MRG) and metallothionein-like proteins (MTLP), respectively. The subcellular sequestration of the elements at the end of the depuration phase did not differ among pH treatments. These results suggest that bioconcentration and tissue/subcellular distribution are element-specific in the oyster, and the effects of higher pCO2 driven acidification and/or coastal acidification variably influence these processes.


Asunto(s)
Radioisótopos de Cadmio/metabolismo , Radioisótopos de Cesio/metabolismo , Radioisótopos de Cobalto/metabolismo , Ostrea/fisiología , Contaminantes Radiactivos del Agua/metabolismo , Animales , Radioisótopos de Cadmio/análisis , Radioisótopos de Cadmio/química , Dióxido de Carbono/química , Radioisótopos de Cesio/análisis , Radioisótopos de Cesio/química , Radioisótopos de Cobalto/análisis , Radioisótopos de Cobalto/química , Concentración de Iones de Hidrógeno , Cinética , Metalotioneína/metabolismo , Océanos y Mares , Agua de Mar/química , Distribución Tisular , Contaminantes Radiactivos del Agua/química
19.
J Environ Radioact ; 189: 146-155, 2018 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-29673949

RESUMEN

Experimentally and theoretically determined shielding factors for a common light construction dwelling type were obtained and compared. Sources of the gamma-emitting radionuclides 60Co and 137Cs were positioned around and on top of a modular building to represent homogeneous fallout. The modular building used was a standard prefabricated structure obtained from a commercial manufacturer. Four reference positions for the gamma radiation detectors were used inside the building. Theoretical dose rate calculations were performed using the Monte Carlo code MCNP6, and additional calculations were performed that compared the shielding factor for 137Cs and 134Cs. This work demonstrated the applicability of using MCNP6 for theoretical calculations of radioactive fallout scenarios. Furthermore, the work showed that the shielding effect for modular buildings is almost the same for 134Cs as for 137Cs.


Asunto(s)
Monitoreo de Radiación/métodos , Ceniza Radiactiva/análisis , Radioisótopos de Cesio , Radioisótopos de Cobalto/análisis , Simulación por Computador , Materiales de Construcción , Método de Montecarlo , Dosis de Radiación , Protección Radiológica/métodos , Protección Radiológica/estadística & datos numéricos , Ceniza Radiactiva/estadística & datos numéricos
20.
Radiol Phys Technol ; 10(4): 454-463, 2017 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-28921448

RESUMEN

This study aimed to evaluate dose uniformity for 192Ir and 60Co stepping sources. High dose rate 192Ir and 60Co stepping sources were simulated by the MCNPX Monte Carlo code. To investigate dose uniformity, treatment lengths of 30, 50, 100, and 150 mm with stepping distances of 3, 5, 7, and 10 mm were considered. Finally, dose uniformity for the 192Ir and 60Co stepping sources with increasing distances from the source were assessed at these treatment lengths and steps. The findings showed that the dose distribution was non-uniform for regions in close vicinity of the source, especially in the high source steps, but for most points at distances >10 mm from the center of the source, the dose distribution was uniform. For most points, the dose uniformity increased with reduction of the source steps and increments of the transverse distance from the source. The dose non-uniformity was similar for most of the corresponding points of 60Co and 192Ir sources with the same treatment lengths and source steps, except at the distance of 150 mm. When using stepping technique for the treatment of tumors, more attention should be focused on treatment planning, especially with higher stepping distances and lower transverse distances from the source.


Asunto(s)
Braquiterapia , Radioisótopos de Cobalto/análisis , Radioisótopos de Iridio/análisis , Fantasmas de Imagen , Planificación de la Radioterapia Asistida por Computador/métodos , Radioisótopos de Cobalto/uso terapéutico , Humanos , Radioisótopos de Iridio/uso terapéutico , Método de Montecarlo , Dosificación Radioterapéutica
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...