Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 878
Filtrar
1.
Sci Rep ; 14(1): 15011, 2024 07 01.
Artículo en Inglés | MEDLINE | ID: mdl-38951565

RESUMEN

This study was performed to analyze fingertip capillary blood sampling in pediatric patients using microcapillary blood collection tubes and microhematocrit tubes and to compare the blood cell analysis results obtained via these two blood collection methods. Finger capillary blood was collected from 110 outpatients using microcapillary blood collection tubes and microhematocrit tubes and complete blood count analysis was performed with a Sysmex XS-900i hematology analyzer and manual microscopy for blood cell morphology. Paired data was evaluated for agreement and bias using the microhematocrit samples as the reference group and the samples from the microcapillary blood collection tubes as the observation group. The two blood collection methods demonstrated good agreement for measuring red blood cell (RBC) parameters (i.e., RBC, Hb, Hct, MCV, MCH and MCHC), wherein the relative bias was > allowable total error (TEa) in 0.91%, 1.82%, 11.82%, 1.82%, 0.91% and 8.18% of the parameter measures, respectively. According to industry requirements, the proportion of samples meeting the acceptable bias level should be > 80%. Additionally, the estimated biases at each medical decision level were within clinically acceptable levels for RBC, Hb, Hct, and MCV. However, the proportion of WBC and PLT counts with relative bias > TEa was 25.45% and 35.45%, respectively. Furthermore, the relative bias of the WBC count at the medical decision level of 0.5 × 109/L and that of the PLT counts at the medical decision levels of 10 × 109/L and 50 × 109/L were clinically significant. Bland-Altman analysis further showed a mean bias of 0.66 × 109/L (95% LoA, - 0.79 to 2.11) for the WBC count and 39 × 109/L (95% LoA, - 46 to 124) for the PLT count from the blood samples collected in the microcapillary blood collection tubes compared with the counts of those collected in the microhematocrit tubes. Neutrophil, monocyte, lymphocyte, eosinophil, and PLT counts increased significantly in the microcapillary blood collection tubes compared with those in the microhematocrit tubes, along with an elevated number of instrument false alarms (P < 0.05). The two capillary blood collection devices exhibit performance differences. Therefore, clinicians should pay attention to the variation in results caused by different blood collection methods.


Asunto(s)
Recolección de Muestras de Sangre , Humanos , Recolección de Muestras de Sangre/métodos , Femenino , Niño , Masculino , Recuento de Células Sanguíneas/métodos , Recuento de Células Sanguíneas/instrumentación , Preescolar , Dedos/irrigación sanguínea , Lactante , Adolescente , Capilares , Recuento de Leucocitos/métodos
2.
Psychoneuroendocrinology ; 168: 107134, 2024 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-39059225

RESUMEN

INTRODUCTION: Schizophrenia spectrum disorders (SSDs) are associated with immune-inflammatory activation. Recently, complete blood count (CBC)-based inflammation indexes such as the neutrophil-to-lymphocyte ratio (NLR), the monocyte-to-lymphocyte ratio (MLR), and the platelet-to-lymphocyte ratio (PLR) have emerged as reproducible and cost-effective inflammation markers in mental disorders. In this study, we aimed at investigating the relationship of NLR, MLR, and PLR with symptom severity in people with SSDs, testing interactions with relevant clinical variables. METHODS: We included inpatients with SSDs aged 18-65 consecutively hospitalized from May 2020 to March 2024. Socio-demographic and clinical data were recorded. CBC-based ratios were estimated from routinely collected blood samples. Structural equation modelling (SEM) was performed to test relationships involving symptom severity constructs and CBC-based ratios, accounting for substance use disorder, antipsychotic treatment, and obesity. RESULTS: Two hundred sixty-six participants met inclusion criteria. The SEM analysis uncovered a significant relationship of MLR with positive (coeff.: 0.19, p=0.048) and negative (coeff.: 0.27, p=0.004) symptoms, also showing a significant link of substance use disorder and antipsychotic treatment with symptom severity as well as of antipsychotic treatment with obesity. CONCLUSIONS: Notwithstanding the cross-sectional design and the somewhat limited sample representativeness, this study showed a significant relationship between the MLR - but not the NLR or the PLR - and the severity of both positive and negative symptoms, testing at the same time the interactions with other clinical variables. Considering the insufficiency and inconsistency of data in this field, further research is needed to validate our findings and elucidate the underlying mechanisms driving the observed relationships between the MLR and SSD symptoms.


Asunto(s)
Inflamación , Análisis de Clases Latentes , Neutrófilos , Esquizofrenia , Índice de Severidad de la Enfermedad , Humanos , Femenino , Masculino , Adulto , Esquizofrenia/sangre , Persona de Mediana Edad , Inflamación/sangre , Recuento de Células Sanguíneas/métodos , Anciano , Adulto Joven , Adolescente , Monocitos/metabolismo , Linfocitos , Plaquetas , Biomarcadores/sangre , Antipsicóticos/uso terapéutico
3.
BMC Geriatr ; 24(1): 432, 2024 May 16.
Artículo en Inglés | MEDLINE | ID: mdl-38755603

RESUMEN

BACKGROUND: It has been proposed that inflammation plays a role in the development of sarcopenia. This study aimed to investigate the links of complete blood cell count (CBC) parameters and CBC-derived inflammatory indicators with sarcopenia and mortality. METHODS: Data pertaining to sarcopenia were extracted from the 1999-2006 National Health and Nutrition Examination Survey (NHANES), and mortality events were ascertained through the National Death Index up to December 31, 2019. The CBC-derived inflammatory indicators assessed in this study included the neutrophil-to-lymphocyte ratio (NLR), derived neutrophil-to-lymphocyte ratio (dNLR), monocyte-to-lymphocyte ratio (MLR), neutrophil-monocyte to lymphocyte ratio (NMLR), systemic inflammatory response index (SIRI), and systemic immune-inflammation index (SII). The prognostic significance of these CBC-derived inflammatory indicators was evaluated using the random survival forests (RSF) analysis. RESULTS: The study encompassed a cohort of 12,689 individuals, among whom 1,725 were diagnosed with sarcopenia. Among individuals with sarcopenia, 782 experienced all-cause mortality, and 195 succumbed to cardiovascular causes. Following adjustment for confounding variables, it was observed that elevated levels of NLR, dNLR, NMLR, SIRI, and SII were associated with an increased prevalence of sarcopenia. Among participants with sarcopenia, those in the highest quartile of NLR (HR = 1.336 [1.095-1.631]), dNLR (HR = 1.274 [1.046-1.550]), MLR (HR = 1.619 [1.290-2.032]), NMLR (HR = 1.390 [1.132-1.707]), and SIRI (HR = 1.501 [1.210-1.862]) exhibited an elevated risk of all-cause mortality compared to those in the lowest quartile of these inflammation-derived indicators. These associations were similarly observed in cardiovascular mortality (HR = 1.874 [1.169-3.003] for MLR, HR = 1.838 [1.175-2.878] for SIRI). The RSF analysis indicated that MLR exhibited the highest predictive power for both all-cause and cardiovascular mortality among individuals with sarcopenia. CONCLUSIONS: Our findings underscore the association between CBC-derived inflammatory indicators and mortality in adults with sarcopenia. Of note, MLR emerged as the most robust predictor of all-cause and cardiovascular mortality in this population.


Asunto(s)
Inflamación , Encuestas Nutricionales , Sarcopenia , Humanos , Sarcopenia/mortalidad , Sarcopenia/epidemiología , Sarcopenia/diagnóstico , Sarcopenia/sangre , Masculino , Femenino , Encuestas Nutricionales/métodos , Encuestas Nutricionales/tendencias , Anciano , Inflamación/sangre , Persona de Mediana Edad , Recuento de Células Sanguíneas/tendencias , Recuento de Células Sanguíneas/métodos , Anciano de 80 o más Años , Neutrófilos , Pronóstico , Adulto , Estados Unidos/epidemiología
4.
PLoS One ; 19(5): e0301845, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38787860

RESUMEN

Differential white blood cell counts are frequently used in diagnosis, patient stratification, and treatment selection to optimize therapy responses. Referral laboratories are often used but challenged with use of different hematology platforms, variable blood shipping times and storage conditions, and the different sensitivities of specific cell types. To extend the scientific literature and knowledge on the temporal commutability of blood samples between hematology analyzers, we performed a comparative ex-vivo study using four of the most utilized commercial platforms, focusing on the assessment of eosinophils given its importance in asthma management. Whole blood from healthy volunteers with and without atopy (n = 6+6) and participants with eosinophilic asthma (n = 6) were stored under different conditions (at 4, 20, 30, and 37°C, with or without agitation) and analyzed at different time points (3, 6, 24, 48 and 72h post-sampling) in parallel on the Abbott CELL-DYN Sapphire, Beckman Coulter DxH900, Siemens ADVIA 2120i and Sysmex XN-1000V. In the same blood samples, eosinophil-derived neurotoxin (EDN), eosinophil activation and death markers were analyzed. All platforms gave comparable measurements of cell differentials on fresh blood within the same day of sampling. However, by 24 hours, significant temporal and temperature-dependent differences were observed, most markedly for eosinophils. None of the platforms performed perfectly across all temperatures tested during the 72 hours, showing that handling conditions should be optimized depending on the cell type of interest and the hematology analyzer. Neither disease status (healthy vs. asthma) nor agitation of the sample affected the cell quantification result or EDN release. The eosinophil activation markers measured by flow cytometry increased with time, were influenced by temperature, and were higher in those with asthma versus healthy participants. In conclusion, hematology analyzer, time window from sampling until analysis, and temperature conditions must be considered when analyzing blood cell differentials, particularly for eosinophils, via central labs to obtain counts comparable to the values obtained in freshly sampled blood.


Asunto(s)
Asma , Eosinófilos , Humanos , Asma/sangre , Asma/diagnóstico , Eosinófilos/citología , Femenino , Masculino , Adulto , Recuento de Células Sanguíneas/instrumentación , Recuento de Células Sanguíneas/métodos , Recuento de Leucocitos/instrumentación , Recuento de Leucocitos/métodos , Persona de Mediana Edad , Hematología/instrumentación , Hematología/métodos
5.
Sci Rep ; 14(1): 10841, 2024 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-38736010

RESUMEN

Optimizing early breast cancer (BC) detection requires effective risk assessment tools. This retrospective study from Brazil showcases the efficacy of machine learning in discerning complex patterns within routine blood tests, presenting a globally accessible and cost-effective approach for risk evaluation. We analyzed complete blood count (CBC) tests from 396,848 women aged 40-70, who underwent breast imaging or biopsies within six months after their CBC test. Of these, 2861 (0.72%) were identified as cases: 1882 with BC confirmed by anatomopathological tests, and 979 with highly suspicious imaging (BI-RADS 5). The remaining 393,987 participants (99.28%), with BI-RADS 1 or 2 results, were classified as controls. The database was divided into modeling (including training and validation) and testing sets based on diagnostic certainty. The testing set comprised cases confirmed by anatomopathology and controls cancer-free for 4.5-6.5 years post-CBC. Our ridge regression model, incorporating neutrophil-lymphocyte ratio, red blood cells, and age, achieved an AUC of 0.64 (95% CI 0.64-0.65). We also demonstrate that these results are slightly better than those from a boosting machine learning model, LightGBM, plus having the benefit of being fully interpretable. Using the probabilistic output from this model, we divided the study population into four risk groups: high, moderate, average, and low risk, which obtained relative ratios of BC of 1.99, 1.32, 1.02, and 0.42, respectively. The aim of this stratification was to streamline prioritization, potentially improving the early detection of breast cancer, particularly in resource-limited environments. As a risk stratification tool, this model offers the potential for personalized breast cancer screening by prioritizing women based on their individual risk, thereby indicating a shift from a broad population strategy.


Asunto(s)
Neoplasias de la Mama , Aprendizaje Automático , Humanos , Neoplasias de la Mama/sangre , Neoplasias de la Mama/diagnóstico , Neoplasias de la Mama/patología , Femenino , Persona de Mediana Edad , Estudios Retrospectivos , Adulto , Anciano , Recuento de Células Sanguíneas/métodos , Medición de Riesgo/métodos , Detección Precoz del Cáncer/métodos , Brasil/epidemiología
6.
Clin Lab ; 70(5)2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38747905

RESUMEN

BACKGROUND: Cold agglutinins (CAs) in blood samples can cause a reversible agglutination of red blood cell (RBC) which result in an incorrect complete blood count (CBC). So, it is important to explore new simple and feasible treatment conditions for clinical work. METHODS: The CAs group included 32 samples with CAs. The parameters of CBC at room temperature or after prewarming at 37°C or 41°C for different time periods were compared. The consistency and correlation of those parameters were analyzed. The morphology of erythrocytes in the CAs group was observed manually. The control group included 45 samples without CAs and prewarmed at 37°C or 41°C for different time periods. The differences were also analyzed. RESULTS: CAs have a significant effect on CBC. After prewarming at 37°C or 41°C the interferences are all corrected. Consider prewarming at 37°C for 120 minutes as the standard procedure. The consistency and correlation analysis showed there was no statistical difference between the results of each subgroup and standard group, except the MCHC of group 41°C 10 minutes. The correlation of parameters between all subgroups and the standard group is satisfied. Microscopic examination showed no RBC aggregation or fragmentation after prewarming at 41°C or 37°C. According to the maximum bias requirements for expert performance in Validation, Verification, and Quality Assurance of Automated Hematology Analyzers, 2nd Edition (CLSI H26-A2), the differences in overall results in control group are negligible. CONCLUSIONS: The 41°C 2 minutes prewarming method is a rapid and effective way for treating samples with CAs. It is an efficient way to obtain more reliable CBC results, without specific instruments.


Asunto(s)
Crioglobulinas , Eritrocitos , Humanos , Crioglobulinas/análisis , Recuento de Células Sanguíneas/métodos , Reproducibilidad de los Resultados , Temperatura , Factores de Tiempo , Agregación Eritrocitaria , Aglutinación
7.
J Clin Apher ; 39(3): e22114, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38708583

RESUMEN

BACKGROUND: Stem cell apheresis in the context of autologous stem cell transplantation requires an accurate cluster of differentiantion 34 (CD34+) count determined by flow cytometry as the current gold standard. Since flow cytometry is a personnel and time-intensive diagnostic tool, automated stem cell enumeration may provide a promising alternative. Hence, this study aimed to compare automated hematopoietic progenitor enumeration carried out on a Sysmex XN-20 module compared with conventional flow cytometric measurements. METHODS: One hundred forty-three blood samples from 41 patients were included in this study. Correlation between the two methods was calculated over all samples, depending on leukocyte count and diagnosis. RESULTS: Overall, we found a high degree of correlation (r = 0.884). Furthermore, correlation was not impaired by elevated leukocyte counts (>10 000/µL, r = 0.860 vs <10 000/µL, r = 0.849; >20 000/µL, r = 0.843 vs <20 000/µL, r = 0.875). However, correlation was significantly impaired in patients with multiple myeloma (multiple myeloma r = 0.840 vs nonmyeloma r = 0.934). SUMMARY: Stem cell measurement carried out on the Sysmex XN-20 module provides a significant correlation with flow cytometry and might be implemented in clinical practice. In clinical decision-making, there was discrepancy of under 15% of cases. In multiple myeloma patients, XN-20 should be used with caution.


Asunto(s)
Antígenos CD34 , Citometría de Flujo , Células Madre Hematopoyéticas , Adulto , Femenino , Humanos , Masculino , Antígenos CD34/análisis , Antígenos CD34/sangre , Recuento de Células Sanguíneas/métodos , Recuento de Células Sanguíneas/instrumentación , Citometría de Flujo/métodos , Células Madre Hematopoyéticas/citología , Recuento de Leucocitos/métodos , Mieloma Múltiple/sangre , Mieloma Múltiple/diagnóstico
8.
J Pediatr ; 271: 114059, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38636783

RESUMEN

OBJECTIVE: To assess concordance between umbilical cord blood (UCB) and neonatal blood (NB) laboratory test results at birth. STUDY DESIGN: This retrospective study considered very preterm neonates (<32 weeks' gestational age) admitted to a tertiary neonatal intensive care unit from 2012 to 2023. Inclusion criteria required neonates with a complete blood count measured in both UCB and NB drawn within 2 hours after birth. Median hemoglobin (Hb) and hematocrit (Hct) concentrations were compared between UCB (venous samples) and NB (venous, arterial, or capillary samples). RESULTS: A total of 432 neonates with paired UCB and NB values were included in the study. Hb concentration in UCB was 14.7 g/dL (IQR 13.5-16.1 g/dL) compared with 14.8 g/dL (IQR 12.6-19.3 g/dL) in venous NB samples, 13.9 g/dL (IQR 12.9-15.3 g/dL) in arterial NB and 18.7 g/dL (IQR 16.6-20.8 g/dL) in capillary NB. The regression equation showed a correction factor of 1.08 for converting Hb values from UCB to venous NB. Median Hct concentration in UCB was 0.45 L/L (IQR: 0.41-0.49 L/L) compared with 0.48 L/L (IQR 0.43-0.54 L/L) in venous NB, 0.42 L/L (IQR 0.38-0.45 L/L) in arterial NB and 0.57 L/L, (IQR 0.51-0.63 L/L) in capillary NB. CONCLUSIONS: Hb and Hct concentrations measured in UCB are similar to those measured in venous blood in very preterm infants and are valid alternatives for NB tests at birth. Hb and Hct concentrations in arterial and capillary NB are respectively lower and higher compared with UCB measurements.


Asunto(s)
Sangre Fetal , Humanos , Recién Nacido , Sangre Fetal/química , Estudios Retrospectivos , Femenino , Masculino , Recuento de Células Sanguíneas/métodos , Hematócrito , Hemoglobinas/análisis , Unidades de Cuidado Intensivo Neonatal , Recien Nacido Prematuro/sangre
9.
Eur J Pediatr ; 183(7): 2983-2993, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38634890

RESUMEN

Early recognition of bloodstream infection (BSI) in infants can be difficult, as symptoms may be non-specific, and culture can take up to 48 h. As a result, many infants receive unneeded antibiotic treatment while awaiting the culture results. In this study, we aimed to develop a model that can reliably identify infants who do not have positive blood cultures (and, by extension, BSI) based on the full blood count (FBC) and C-reactive protein (CRP) values. Several models (i.e. multivariable logistic regression, linear discriminant analysis, K nearest neighbors, support vector machine, random forest model and decision tree) were trained using FBC and CRP values of 2693 infants aged 7 to 60 days with suspected BSI between 2005 and 2022 in a tertiary paediatric hospital in Dublin, Ireland. All models tested showed similar sensitivities (range 47% - 62%) and specificities (range 85%-95%). A trained decision tree and random forest model were applied to the full dataset and to a dataset containing infants with suspected BSI in 2023 and showed good segregation of a low-risk and high-risk group. Negative predictive values for these two models were high for the full dataset (> 99%) and for the 2023 dataset (> 97%), while positive predictive values were low in both dataset (4%-20%).   Conclusion: We identified several models that can predict positive blood cultures in infants with suspected BSI aged 7 to 60 days. Application of these models could prevent administration of antimicrobial treatment and burdensome diagnostics in infants who do not need them. What is Known: • Bloodstream infection (BSI) in infants cause non-specific symptoms and may be difficult to diagnose. • Results of blood cultures can take up to 48 hours. What is New: • Machine learning models can contribute to clinical decision making on BSI in infants while blood culture results are not yet known.


Asunto(s)
Proteína C-Reactiva , Aprendizaje Automático , Humanos , Lactante , Proteína C-Reactiva/análisis , Recién Nacido , Masculino , Femenino , Recuento de Células Sanguíneas/métodos , Bacteriemia/diagnóstico , Bacteriemia/sangre , Estudios Retrospectivos , Sepsis/diagnóstico , Sepsis/sangre , Sepsis/microbiología , Valor Predictivo de las Pruebas , Árboles de Decisión , Biomarcadores/sangre , Sensibilidad y Especificidad
10.
J Appl Lab Med ; 9(4): 833-847, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38549553

RESUMEN

BACKGROUND: The most ordered laboratory test worldwide is the complete blood count (CBC). CONTENT: In this primer, an introduction to platelet testing in the context of the CBC is provided with a discussion of the laboratory evaluation of platelet abnormalities including thrombocytopenia and thrombocytosis. SUMMARY: As clinical chemists continue to be tasked to direct laboratories outside of the traditional clinical chemistry sections such as hematology, expertise must be developed. This primer is dedicated to that effort.


Asunto(s)
Plaquetas , Trombocitopenia , Trombocitosis , Humanos , Trombocitosis/sangre , Trombocitosis/diagnóstico , Trombocitopenia/diagnóstico , Trombocitopenia/sangre , Recuento de Plaquetas/métodos , Recuento de Células Sanguíneas/métodos , Recuento de Células Sanguíneas/instrumentación , Química Clínica/métodos , Química Clínica/normas
11.
Clin Lab ; 70(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38345977

RESUMEN

BACKGROUND: The benchtop ADVIA 560 AL hematology analyzer (Siemens Healthineers Tarrytown, NY, USA) offers a small footprint and ease of operation making it suitable for satellite laboratories and intensive care units. A verification study of this analyzer was performed. METHODS: Between- and intra-run precision, carry-over, linearity, and throughput were evaluated on the ADVIA 560 AL. Accuracy was assessed on 94 patient samples by comparing the results obtained on the ADVIA 560 AL to the results on the reference Sysmex XN1000 analyzer (Sysmex Corporation, Kobe, Japan). RESULTS: The ADVIA 560 AL showed acceptable imprecision on control material and minimal bias in comparison to the XN 1000 on patient samples with a throughput of 60 samples per hour. The percentage carryover was not significant and the linearity was within acceptable limits. CONCLUSIONS: The ADVIA 560 AL bench-top analyzer is suitable for acute care centers and satellite laboratories owing to its small footprint, ease of use, and reproducible and accurate results.


Asunto(s)
Hematología , Humanos , Recuento de Células Sanguíneas/métodos , Reproducibilidad de los Resultados , Hematología/métodos , Laboratorios , Japón , Recuento de Leucocitos
12.
J Clin Lab Anal ; 38(4): e25017, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38396348

RESUMEN

BACKGROUND: Three-part differential (3PD) haematology analysers offer a quick, easy-to-use and economical way to acquire important information about a patient's physiology. In this study, we evaluated a new 3PD analyser, the Sysmex XQ-320, investigated its comparability with its predecessor (Sysmex XP-300) and the five-part differential analyser Sysmex XN-9000, and explored its flagging potential. METHODS: Analytical performance studies were conducted for repeatability, within-laboratory precision, between-day precision, carry-over and linearity with fresh blood and QC material. Method comparison was performed in 493 samples comparing XQ-320 with XP-300, using the XN-9000 as the gold standard. RESULTS: The XQ-320 excelled manufacturer's specifications in the analytical performance studies, except for MXD in within-laboratory and between-day precisions using the QC material level 1. The XQ-320 showed correlation values greater than 0.94 with XN-9000 for the majority of the 20 reportable parameters (MXD# 0.891, MXD% 0.898 and MCHC 0.849). Improvements over the XP-300 were observed in WBC in the leucocytopenic range (bias -0.038 vs. -0.097) and PLT (bias 2.568 vs. -7.877, intercept 3.880 vs. -8.845). Concordance between XQ-320 and XP-300 was 91.9% for the WBC histogram abnormal distribution flag and 95.3% for the PLT flag. Patterns of increased neutrophils and decreased mixed cells on the XQ-320 were observed in samples that raised a flag on XN-9000. CONCLUSION: The XQ-320 showed excellent analytical performance, and very good to excellent correlation with XN-9000 with improvements over XP-300. Flagging combined with parameter patterns identified additional suspected abnormal samples, thus making the XQ-320 an excellent solution for laboratories utilising 3PD analysers.


Asunto(s)
Hematología , Humanos , Laboratorios , Nonoxinol , Recuento de Células Sanguíneas/métodos , Reproducibilidad de los Resultados
13.
Int J Lab Hematol ; 46(3): 466-473, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38263481

RESUMEN

INTRODUCTION: Cell population data (CPD) parameters may be putative biomarkers for the screening of various diseases including some infections and myelodysplastic syndrome. This study aimed to establish the age- and sex-specific reference intervals (RIs) for the CPD parameters in the Korean population. METHODS: The reference population for the RIs of CPD parameters comprised 124 856 subjects aged 20-99 years. CPD parameters were obtained from Sysmex XN-2000 (Kobe, Japan) datasets from 17 health promotion centers in 13 South Korean cities. We determined significant partitions for age and sex, and calculated RIs according to Clinical and Laboratory Standards Institute C28-A3 guidelines. RESULTS: The side scattered light intensity in the neutrophil area and the lymphocyte area did not require sex-related partitioning except in those over the age of 50, among whom the lower limit (LL) and upper limit (UL) were lower in females. However, the side scattered light distribution width in the lymphocyte area required age- and sex-related partitioning, in which LL and UL were higher in females. The LL and UL of the fluorescent light distribution width were higher in males in the neutrophil area and higher in females in the lymphocyte area, but age-related partitioning was not required. The forward scattered light intensity in the neutrophil area, lymphocyte area, and monocyte area did not require age-related partitioning in males. CONCLUSION: This study has determined comprehensive age- and sex-specific RIs for CPD parameters, which could help to prove the clinical significance of these parameters in the Sysmex XN-2000.


Asunto(s)
Neutrófilos , Humanos , Masculino , Femenino , Anciano , República de Corea , Adulto , Persona de Mediana Edad , Anciano de 80 o más Años , Valores de Referencia , Recuento de Células Sanguíneas/instrumentación , Recuento de Células Sanguíneas/normas , Recuento de Células Sanguíneas/métodos , Factores de Edad , Adulto Joven , Neutrófilos/citología , Envejecimiento
14.
Transfus Med ; 34(1): 30-38, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-38193379

RESUMEN

OBJECTIVES: Our objective was to compare the measurement of residual white blood cell (rWBC) and residual red blood cell (rRBC) counts in blood products using the XN Blood Bank mode and the laboratory standard operating procedures for manual counts. In addition, to compare the whole blood complete blood count (CBC) values of blood donors and the quality of blood products using the Sysmex XN analyser versus the XS-1000i analyser. MATERIALS AND METHODS: For blood donors, 190 samples from blood or apheresis donors were analysed on both the Sysmex XS-1000i and XN-1000 analysers and the mean values of six CBC parameters were compared: the white blood cell count (WBC), the red blood cell count (RBC), haemoglobin (HGB), haematocrit (HCT), the mean corpuscular volume (MCV), the platelet count (PLT). For blood products, 164 samples were collected: 13 Plasma products - whole blood, 9 Plasma products - apheresis, 36 RBC concentrates - whole blood, 30 PLT concentrates - buffy coats, 36 PLT concentrates - buffy coats - pooled and 55 PLT concentrates - apheresis. RESULTS: All CBC parameters of the blood donors tested showed similar performance, with excellent correlation coefficients (r) ranging from 0.821 to 0.995. The majority of the blood products did not have a quantifiable number of residual cells, meaning the number of rWBC and rRBC, if present, was below the limit of quantitation (LoQ) of the different methods. rWBC were detected by Blood Bank mode in Plasma products - whole blood with a mean rWBC of 0.012 × 109 /L and in PLT concentrates - buffy coats with a mean rWBC of 0.19 × 109 /L. The correlation coefficient in both analysers for all three parameters (HGB, HCT, RBC) in RBC concentrates - whole blood was excellent, ranging from 0.95 to 0.99. For platelet count, r ranged from 0.98 to 0.99. CONCLUSION: The XN-Series analyser, equipped with a Blood Bank mode, demonstrated reliable performance when used for blood donor evaluation, rWBC enumeration and measurement of end blood products.


Asunto(s)
Bancos de Sangre , Donantes de Sangre , Humanos , Recuento de Células Sanguíneas/métodos , Recuento de Plaquetas , Eritrocitos
15.
Int J Lab Hematol ; 46(1): 63-71, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37731006

RESUMEN

INTRODUCTION: The Atellica Hema (Siemens Healthineers, Tarrytown, NY, USA) is a new generation multi-parameter analyzer for full blood count, 6-part differential and reticulocyte testing by impedance variation and fluorescence flow cytometry. In this study, we verified the whole blood and limited body fluid modes of the Atellica Hema 580. METHODS: We evaluated precision, linearity, carry-over, throughput and performed a method comparison to assess the performance of the Atellica Hema 580. For comparison of the Atellica Hema 580 with the Sysmex XN-1000 (Sysmex, Kobe, Japan), 140 samples from adult and pediatric patients including both normal and abnormal hematology profiles were analyzed in parallel. RESULTS: The Atellica Hema 580 demonstrated acceptable imprecision within the manufacturer's specifications for whole blood and body fluid modes, good linearity for high and low ranges and no significant carryover. The full blood count, differential and reticulocyte correlated well with the Sysmex XN-1000, except for mean cell hemoglobin concentration, basophil and large immature cells. The optical platelet count, reflexed in 34 samples with a platelet count <150 × 109 /l, showed a strong correlation with the fluorescent platelet count on the Sysmex XN-1000. The morphology flagging efficiency was 92% for white blood cells, 95% for red blood cells and 87% for platelets. CONCLUSION: The Atellica Hema 580 showed good analytical performance and workflow efficiency for a wide range of patient samples.


Asunto(s)
Hematología , Adulto , Humanos , Niño , Recuento de Células Sanguíneas/métodos , Hematología/métodos , Recuento de Plaquetas/métodos , Leucocitos , Plaquetas , Reproducibilidad de los Resultados
16.
J Equine Vet Sci ; 132: 104984, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38081332

RESUMEN

Asinina de Miranda is a protected donkey sub-species from the Mirandês plateau in northeastern of Portugal. Donkeys are animals that have substantially lost their place as working animals in modern society, this had led to a decrease in their population numbers. A need to preserve native species has led to the foundation of organizations like Associação para o Estudo e Proteção do Gado Asinino (AEPGA) and the development of studies regarding breed welfare, such as hematology. The IDEXX ProCyte Dx is a veterinary hematology analyzer validated for several species, but not for donkeys. The aim of this study was to validate the ProCyte Dx for Asinina de Miranda donkeys. The validation requires a controlled study of precision, carryover, linearity and comparison between the equipment and the manually obtained values for the leukocyte differential count and hematocrit. Results indicated coefficient of variation was good (below 5 %) for both the intra-assay and the inter-assay precision, except for basophils. Carryover was 0 % for all the parameters except platelets (5.88 %). Linearity showed a very high Pearson correlation coefficient, above 0.99, for erythrocytes, hematocrit, hemoglobin, leucocytes, neutrophils, lymphocytes, monocytes, eosinophils, platelets and plateletcrit. Comparison demonstrated excellent agreement for hematocrit (rs=0.96) and good Spearman rank correlation for neutrophils (rs=0.84) and lymphocytes (rs=0.90). Accuracy for total leukocyte count and platelets could not be determined. In conclusion, the ProCyte Dx seems appropriate to be used in Asinina de Miranda hematology.


Asunto(s)
Equidae , Hematología , Animales , Recuento de Células Sanguíneas/métodos , Recuento de Células Sanguíneas/veterinaria , Reproducibilidad de los Resultados , Recuento de Leucocitos/veterinaria , Hematología/métodos
17.
Einstein (Sao Paulo) ; 21: eAO0501, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-38126661

RESUMEN

OBJECTIVE: This study aimed to compare the hematological parameters released by hematological analyzers with those released in customer reports. METHODS: We conducted a descriptive study in the laboratories of a medium-sized municipality in the state of Minas Gerais registered in the National Register of Health Establishments. Interviews were conducted using a questionnaire to obtain information regarding the parameters released by the analyzers and those available in the customer's report. RESULTS: Sixteen laboratories were evaluated, and none of them released all the parameters obtained from the hematological analyzers to customers. The red blood cell distribution width was released in 88% of the laboratories, atypical lymphocytes in 70%, mean platelet volume in 50%, platelet distribution width and platelet count in 20%. No laboratory released information on reticulocytes, fraction of immature reticulocytes and immature granulocytes, nucleated erythrocyte count, immature platelet fraction and reticulocyte hemoglobin, and large platelet rate. CONCLUSION: All evaluated clinical analysis laboratories had at least one parameter that was not released in the customer's report despite being released by the hematological analyzers. The lack of knowledge on the part of professionals about the clinical importance of each parameter of the complete blood count results in a loss in patient assessment, and it is important to include these parameters in the complete blood count report.


Asunto(s)
Plaquetas , Índices de Eritrocitos , Humanos , Recuento de Células Sanguíneas/métodos , Recuento de Eritrocitos/métodos , Recuento de Plaquetas/métodos
18.
Int J Lab Hematol ; 45(5): 691-699, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37338111

RESUMEN

INTRODUCTION: The manual differential count has been recognized for its disadvantages, including large interobserver variability and labor intensiveness. In this light, automated digital cell morphology analyzers have been increasingly adopted in hematology laboratories for their robustness and convenience. This study aims to evaluate the white blood cell differential performance of the Mindray MC-80, the new automated digital cell morphology analyzer. METHODS: The cell identification performance of Mindray MC-80 was evaluated for sensitivity and specificity using pre-classification and post-classification of each cell class. The method comparison study used manual differentials as the gold standard for calculating Pearson correlation, Passing-Bablok regression, and Bland-Altman analysis. In addition, the precision study was performed and evaluated. RESULTS: The precision was within the acceptable limit for all cell classes. Overall, the specificity of cell identification was higher than 95% for all cell classes. The sensitivity was greater for 95% for most cell classes, except for myelocytes (94.9%), metamyelocytes (90.9%), reactive lymphocytes (89.7%), and plasma cells (60%). Pre-classification and post-classification results correlated well with the manual differential results for all the cell types investigated. The regression coefficients were greater than 0.9 for most cell classes except for promyelocytes, metamyelocytes, basophils, and reactive lymphocytes. CONCLUSION: The performance of Mindray MC-80 for white blood cell differentials is reliable and seems to be acceptable even in abnormal samples. However, the sensitivity is less than 95% for certain abnormal cell types, so the user should be aware of this limitation where such cells are suspected.


Asunto(s)
Hematología , Leucocitos , Humanos , Recuento de Leucocitos , Reproducibilidad de los Resultados , Recuento de Células Sanguíneas/métodos , Hematología/métodos , Células Plasmáticas
19.
Int J Lab Hematol ; 45(5): 659-667, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37128804

RESUMEN

INTRODUCTION: This study assessed the comparability of complete blood count (CBC) parameters between capillary and venous samples, and extended previous research by examining the influence of different storage temperatures on CBC stability up to 7 days after sample collection. METHODS: Venous and capillary blood samples were collected from 93 adult patients. Hemoglobin (Hb), hematocrit (Ht), mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), mean corpuscular hemoglobin concentration (MCHC), mean platelet volume (MPV), leukocytes, lymphocytes, basophils, eosinophils, erythrocytes, red cell distribution width (RDW), immature granulocytes (IG), immature reticulocyte fraction (IRF), monocytes, neutrophils, platelets, and reticulocytes were measured. Deming regression and mean relative differences between venous and capillary measurements were contrasted with desirable total allowable error (TEa). Stability was assessed in 20-27 venous blood samples stored at 4, 21-22, or 30°C, and analyzed at 0, 24, 48, 72, 96, 120, 144, and 168 h. Mean relative change with respect to baseline measurements was compared to the desirable TEa to determine acceptable stability. RESULTS: Deming regression demonstrated strong linear correlations and acceptable variation between venous and capillary measurements. Erythrocytes, Hb, Ht, MCH, MCV, RDW, reticulocytes, and platelets showed acceptable stability for at least 96 h at 4°C. Mean relative change exceeded desirable TEa after 24 h at 30°C for all parameters, except erythrocytes, Hb, leukocytes, and MCH. CONCLUSION: Clinical laboratory specialists and clinicians should be aware of potential differences between venous and capillary measurements, and the influence of storage conditions. Clinical validity of delayed CBC analysis depends on the clinical situation and required precision of the result.


Asunto(s)
Índices de Eritrocitos , Eritrocitos , Adulto , Humanos , Recuento de Células Sanguíneas/métodos , Hematócrito , Eritrocitos/química , Hemoglobinas/análisis , Eosinófilos
20.
Ann Lab Med ; 43(5): 418-424, 2023 09 01.
Artículo en Inglés | MEDLINE | ID: mdl-37080742

RESUMEN

Background: Delta checks increase patient safety by identifying automated hematology analyzer errors. International standards and guidelines for the complete blood count (CBC) delta check method have not been established. We established an effective, practical CBC delta check method and criteria. Methods: We assessed five delta check methods for nine CBC items (Hb, mean corpuscular volume, platelet count, white blood cell [WBC] count, and five-part WBC differential counts) using 219,804 blood samples from outpatients and inpatients collected over nine months. We adopted the best method and criteria and evaluated them using 42,652 CBC samples collected over two weeks with a new workflow algorithm for identifying test errors and corrections for Hb and platelet count. Results: The median delta check time interval was 1 and 21 days for inpatients and outpatients (range, 1-20 and 1-222 days), respectively. We used delta values at 99.5% as delta check criteria; the criteria varied among the five methods and between outpatients and inpatients. The delta percent change (DPC)/reference range (RR) rate performed best as the delta check for CBC items. Using the new DPC/RR rate method, 1.7% of total test results exceeded the delta check criteria; the retesting and resampling rates were 0.5% and 0.001%, respectively. Conclusions: We developed an effective, practical delta check method, including RRs and delta check time intervals, and delta check criteria for nine CBC items. The criteria differ between outpatients and inpatients. Using the new workflow algorithm, we can identify the causes of criterion exceedance and report correct test results.


Asunto(s)
Hematología , Humanos , Recuento de Células Sanguíneas/métodos , Recuento de Leucocitos , Recuento de Plaquetas , Control de Calidad , Hematología/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...