Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 705
Filtrar
2.
Artículo en Alemán | MEDLINE | ID: mdl-36323292

RESUMEN

The first part of this case report describes the surgical treatment of a unilateral mandibular fracture in the standing horse by using a fixateur type I. By the time of implant removal, the fracture had completely healed. However, during implant removal, an implant failure of 2 of the 4 implants occurred with fragments remaining in the bone. The second part of the report focuses on the development of a special surgical instrument that was designed for removal of the implant fragments. Furthermore, the surgical method allowing the entire extirpation of the fragments within a second surgery is described.According to the authors' knowledge, this is the first case report showing the use of the presented surgical technique for the treatment of a mandibular fracture in the standing horse. Additionally, this report also provides an approach for removing implant fragments from the depth of the bone which may occur in case of implant breakage as a potential complication of the described surgery.


Asunto(s)
Remoción de Dispositivos , Fracturas Mandibulares , Animales , Remoción de Dispositivos/efectos adversos , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/veterinaria , Falla de Equipo/veterinaria , Caballos , Fracturas Mandibulares/cirugía , Fracturas Mandibulares/veterinaria
3.
Acta Med Okayama ; 75(6): 751-754, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34955545

RESUMEN

The improved cemented cup technique has attained excellent long-term results in primary total hip arthroplasty. When cup revision surgery was performed, the cemented cup, which was loosened at the bone-cement interface, was easily removed. However, with a well-fixed bone-cement interface, it remains difficult to remove the cemented cup for a revision in the event of a recurring dislocation. In addition, protrusions in the cement can cause unpredictable bone defects. A new removal device was created and used successfully to remove a well-fixed cemented cup safely and efficiently. This report introduces the device and the technique used in cemented cup removal.


Asunto(s)
Artroplastia de Reemplazo de Cadera , Cementos para Huesos , Remoción de Dispositivos/instrumentación , Reoperación/instrumentación , Anciano , Femenino , Humanos
5.
Int Heart J ; 62(5): 1153-1155, 2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34544965

RESUMEN

A 60-year old male with paroxysmal atrial fibrillation underwent a combined procedure of left atrial appendage occlusion and pulmonary vein isolation. However, an acute intraprocedural 24-mm Watchman device dislodgement occurred, and thus a decision for urgent surgery was made. However, it was noted during the surgery that the device had migrated further to the descending aorta, just distal to the left subclavian artery. Since a right sternotomy access for retrieval was not feasible, a percutaneous approach was justified. A homemade snare was created using a combination of a long sheath, J-wire, and a regular snare, and the device was successfully retrieved without significant difficulty.


Asunto(s)
Apéndice Atrial/cirugía , Fibrilación Atrial/cirugía , Procedimientos Quirúrgicos Cardíacos/tendencias , Remoción de Dispositivos/instrumentación , Dispositivo Oclusor Septal/efectos adversos , Aorta Torácica/cirugía , Cateterismo Cardíaco/métodos , Procedimientos Quirúrgicos Cardíacos/métodos , Terapia Combinada/métodos , Humanos , Masculino , Persona de Mediana Edad , Venas Pulmonares/cirugía , Arteria Subclavia/cirugía , Resultado del Tratamiento
6.
Int Heart J ; 62(5): 1156-1159, 2021 Sep 30.
Artículo en Inglés | MEDLINE | ID: mdl-34544971

RESUMEN

A rare complication about "Twiddler syndrome" is reported, and an interesting image about "double twist" is presented. A 78-year-old woman received a single-chamber implantable cardioverter defibrillator (ICD) for secondary prevention of ventricular arrhythmia. After she played mahjong (a traditional Chinese board game) overnight, her ICD lead sense amplitude decreased suddenly and did not recover. The intracardiac electrogram of ICD also found ventricular lead noise before this episode. Chest radiography revealed a twisted lead at the ICD pocket and a twisted and retracted ICD lead in the right atrium. An old ICD lead could not be straightened and removed, and a new ICD lead was implanted at the right ventricle. Anti-coagulation was used to prevent thrombosis for the old ICD lead.


Asunto(s)
Desfibriladores Implantables/efectos adversos , Electrodos Implantados/efectos adversos , Prevención Secundaria/métodos , Taquicardia Ventricular/cirugía , Anciano , Anticoagulantes/uso terapéutico , Remoción de Dispositivos/instrumentación , Electrocardiografía/métodos , Falla de Equipo , Femenino , Ventrículos Cardíacos/fisiopatología , Ventrículos Cardíacos/cirugía , Humanos , Trombosis/prevención & control , Resultado del Tratamiento
7.
Pacing Clin Electrophysiol ; 44(5): 895-902, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33675073

RESUMEN

BACKGROUND: There are limited data on the comparative analyses of TightRail rotating dilator sheath (Philips) and laser sheath for lead extraction. OBJECTIVE: To evaluate the effectiveness and safety of the TightRail sheath as a primary or secondary tool for transvenous lead extraction (TLE). METHODS: Retrospective cohort analysis of 202 consecutive patients who underwent TLE using either TightRail sheath and/or GlideLight laser sheath (Philips) in our hospital. The study population was divided into three groups: Group A underwent TLE with laser sheath only (N = 157), Group B with TightRail sheath only (N = 22), and Group C with both sheaths (N = 23). RESULTS: During this period, 375 leads in 202 patients were extracted, including 297 leads extracted by laser sheath alone, 45 leads by TightRail sheath alone, and 33 by both TightRail sheath and laser sheaths. The most common indications included device infection (44.6%) and lead-related complications (44.1%). The median age of leads was 8.9 years. TightRail sheath (Group B) achieved similar efficacy as a primary extraction tool compared with laser sheath (Group A), with complete procedure success rate of 93.3% (vs. 96.6%, P = .263) and clinical success rate of 100.0% (vs. 98.1%, P = .513). Among 32 leads in which Tightrail was used after laser had failed (Group C), the complete procedure success rate was 75.8%. No significant difference in procedural adverse events was observed. CONCLUSION: Our single-center experience confirms that the TightRail system is an effective first-line and second-line method for TLE. Further investigation is required to guide the selection of mechanical and laser sheaths in lead extraction cases.


Asunto(s)
Remoción de Dispositivos/instrumentación , Electrodos Implantados , Desfibriladores Implantables , Diseño de Equipo , Femenino , Humanos , Rayos Láser , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Estudios Retrospectivos
10.
Ann Vasc Surg ; 73: 532-537, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33508453

RESUMEN

BACKGROUND: Venoarterial extracorporeal membrane oxygenation (VA-ECMO) can be undertaken surgically, but there are various problems with this method. METHODS AND CASE REPORT: We removed the arterial cannula of VA-ECMO percutaneously by combining intravascular balloon dilatation and the Perclose ProGlide™ (PP) closure device in a short amount of time and the extent of bleeding was extremely small. Simultaneously, the venous cannula was removed by suturing and manual compression. We report a series of cases of percutaneous removal of VA-ECMO using intravascular balloon dilatation and PP. CONCLUSIONS: By using this method, VA-ECMO removal was possible in a very short amount of time with minimal invasiveness.


Asunto(s)
Oclusión con Balón , Catéteres de Permanencia , Remoción de Dispositivos/instrumentación , Procedimientos Endovasculares/instrumentación , Oxigenación por Membrana Extracorpórea/instrumentación , Hemorragia/prevención & control , Dispositivos de Acceso Vascular , Dispositivos de Cierre Vascular , Anciano de 80 o más Años , Remoción de Dispositivos/efectos adversos , Procedimientos Endovasculares/efectos adversos , Femenino , Hemorragia/etiología , Humanos , Masculino , Persona de Mediana Edad , Factores de Tiempo , Resultado del Tratamiento
11.
Urologia ; 88(2): 130-134, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33325327

RESUMEN

OBJECTIVE: Flexible cystoscopy for ureteral stent removal after ureteroscopy is widely performed. In this scenario, the real need for antimicrobial prophylaxis is still uncertain. Aim of this study is to determine the urinary tract infections rate after 4 weeks from outpatient flexible cystoscopies for ureteral stent removal without antimicrobial prophylaxis. PATIENTS AND METHODS: A prospective observational study was performed between November 2017 and August 2018 in a single, high-volume Institution.Risk factors for UTIs were recorded. Immediately before cystoscopy, each patient submitted a voided urine specimen. Antibiotics were not given before or after cystoscopy. About 7 and 28 days after cystoscopy all the patients underwent abdomen US, urine analysis and culture, and clinical evaluation to assess possible symptoms of UTI. RESULTS: A total of 192 patients were enrolled in the study, 76 patients (39.2%) were female. Median age was 55 years [IQR 47- 68]. Median BMI was 24.2 [22.9-26.7]. Eighteen patients (9.4%) had asymptomatic bacteriuria before cystoscopy and 39 (20.3%) had positive culture at 7 days. About 21 patients (10.9%) were diagnosed with febrile UTI in the 28 days FU period. The 28.6 % of the Febrile patients had asymptomatic bacteriuria before the stent removal (p < 0.001), this group was slightly older (p = 0.085) and with higher BMI (p = 0.036).Forty-eight patients had positive urine culture at 7 days, of whom 27 (14.1%) were asymptomatic and were classified as asymptomatic bacteriuria. Multivariate analysis shows that only high BMI and bacteriuria before the procedure were significantly associated with developing a febrile UTI, none of the other risk factors was significant. CONCLUSION: Our data show a high rate of UTI after flexible cystoscopies for ureteral stent removal without antimicrobial prophylaxis especially in patients with asymptomatic bacteriuria, in those with high BMI and in the elderly; in these subgroups, antimicrobial prophylaxis should be recommended.


Asunto(s)
Cistoscopios , Cistoscopía , Remoción de Dispositivos/instrumentación , Complicaciones Posoperatorias/epidemiología , Stents , Uréter/cirugía , Infecciones Urinarias/epidemiología , Anciano , Profilaxis Antibiótica , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
13.
AJR Am J Roentgenol ; 216(3): 563-569, 2021 03.
Artículo en Inglés | MEDLINE | ID: mdl-33206563

RESUMEN

Despite inferior vena cava (IVC) filter practice spanning over 50 years, interventionalists face many controversies in proper utilization and management. This article reviews recent literature and offers opinions on filter practices. IVC filtration is most likely to benefit patients at high risk of iatrogenic pulmonary embolus during endovenous intervention. Filters should be used selectively in patients with acute trauma or who are undergoing bariatric surgery. Retrieval should be attempted for perforating filter and fractured filter fragments when imaging suggests feasibility and favorable risk-to-benefit ratio. Antibiotic prophylaxis should be considered when removing filters with confirmed gastrointestinal penetration. Anticoagulation solely because of filter presence is not recommended except in patients with active malignancy. Anticoagulation while filters remain in place may decrease long-term filter complications in these patients. Patients with a filter and symptomatic IVC occlusion should be offered filter removal and IVC reconstruction. Physicians implanting filters may maximize retrieval by maintaining physician-patient relationships and scheduling follow-up at time of placement. Annual follow-up allows continued evaluation for removal or replacement as appropriate. Advanced retrieval techniques increase retrieval rates but require caution. Certain cases may require referral to experienced centers with additional retrieval resources. The views expressed should help guide clinical practice, future innovation, and research.


Asunto(s)
Remoción de Dispositivos/métodos , Implantación de Prótesis/métodos , Embolia Pulmonar/prevención & control , Filtros de Vena Cava , Vena Cava Inferior , Trombosis de la Vena/prevención & control , Profilaxis Antibiótica , Anticoagulantes/administración & dosificación , Cirugía Bariátrica , COVID-19/complicaciones , Remoción de Dispositivos/instrumentación , Procedimientos Endovasculares , Humanos , Neoplasias/complicaciones , Relaciones Médico-Paciente , Guías de Práctica Clínica como Asunto , Diseño de Prótesis , Recurrencia , Medición de Riesgo , Filtros de Vena Cava/efectos adversos , Trombosis de la Vena/etiología , Heridas y Lesiones/complicaciones
14.
Pacing Clin Electrophysiol ; 44(1): 120-128, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-33067867

RESUMEN

The aim of this study was to evaluate the efficacy and safety of the stepwise mechanical transvenous lead extraction approach in a patient population with chronically implanted transvenous leads with a long dwell time. From January 2014 till December 2018, all lead extractions with lead dwell time ≥5 years performed at our tertiary centre were retrospectively analysed. A total of 173 leads, from 78 patients (median age 68 years; 81% male) with a median dwell time of 9 years (interquartile range [IQR] 5) were extracted, with three or more leads in 42% of the patients. Right atrial leads: 41%; right ventricular pacing leads: 16%; implantable cardioverter-defibrillator (ICD) leads: 31% (72% dual coil); coronary sinus leads: 12%. The majority (75%) of the leads had an active fixation. Most frequent indication for extraction was pocket infection/erosion (76%). Overall clinical success was 97%, and complete procedural success was 93%. Venous patency, assessed with venous angiography, was well preserved in 93% of the cases. The overall procedural complication rate was 3.8% (2.6% major and 1.3% minor). Despite the complexity of the population and a very long dwell time (median 9 years), a clinical success rate of 97% was achieved with the stepwise mechanical approach. Analysis of impeding progression of pectoral extraction suggests that dense fibrosis and sharp lead curvature in the transvenous trajectory pose a challenge. Complication rate was low, and acute venous patency was generally well preserved.


Asunto(s)
Remoción de Dispositivos/instrumentación , Electrodos Implantados , Anciano , Desfibriladores Implantables , Femenino , Humanos , Masculino , Persona de Mediana Edad , Marcapaso Artificial , Estudios Retrospectivos
15.
Am J Emerg Med ; 46: 238-240, 2021 08.
Artículo en Inglés | MEDLINE | ID: mdl-33046320

RESUMEN

BACKGROUND: Ring tourniquet occurs when a ring becomes entrapped due to swelling or trauma. As the finger expands the blood flow restriction causes additional swelling, which can lead to nerve damage and other complications. Ring tourniquet can be an emergency that requires rapid ring removal. Standard devices for ring removal have been described but rarely tested. We conducted a randomized study to compare removal time, user and participant satisfaction and complications between a motorized diamond disc ring cutter (MDDRC) and a ring cutter attached to trauma shears (TS). METHODS: In pairs, emergency medicine providers removed rings using both devices and wore randomized rings to be removed (silver or steel). Each effort was timed from initiation to removal. After each effort both user and subject rated their satisfaction with the device, using a visual analog scale and reported any complications. Median and interquartile ranges were generated for the primary and secondary outcomes with 95% confidence intervals where applicable. Wilcoxon Rank Sum tests were calculated with a = 0.05 to compare removal time and secondary outcomes between the two tools. RESULTS: Thirty subjects completed the study. Median time to ring removal was significantly lower with the TS compared to the MDDRC (7.7 vs 67.0 s, p < .0001). Device user satisfaction (9.7/10 vs 3.8/10, p < .0001) and participant satisfaction (9.7/10 vs 6.8/10, p < .0001) were significantly higher with the TS, while participant discomfort was significantly lower with the TS (0.0/10 vs 2.2/10, p < .0001). CONCLUSION: This study is the first to compare efficacy, satisfaction and complications of two standard tools for removal of ring tourniquets. The TS took significantly less time than the GEM MDDRC and demonstrated significantly better satisfaction for both the ring wearer and ring remover.


Asunto(s)
Remoción de Dispositivos/instrumentación , Dedos/irrigación sanguínea , Joyas/efectos adversos , Torniquetes , Voluntarios Sanos , Humanos , Proyectos Piloto
16.
BMJ Case Rep ; 13(12)2020 Dec 22.
Artículo en Inglés | MEDLINE | ID: mdl-33370975

RESUMEN

A 52-year-old man presented with lower urinary tract symptoms and intermittent haematuria for the last 6 months. He had undergone totally extraperitoneal right inguinal hernia repair a decade ago. The ultrasonography and an X-ray of the pelvis suggested a large radio-opaque shadow in the bladder. However, CT revealed an encrusted intravesical extension of the migrated mesh along the right anterolateral wall. The entire intravesical part of the migrated mesh with encrustations was successfully retrieved by endourological approach using holmium laser. The patient symptomatically improved and at follow-up, cystoscopy showed a complete re-epithelisation of the bladder mucosa. The intravesical extension of migrated mesh is a rare but challenging complication following mesh hernioplasty and can be successfully managed with a complete endoscopic approach.


Asunto(s)
Remoción de Dispositivos/métodos , Migración de Cuerpo Extraño/cirugía , Herniorrafia/efectos adversos , Láseres de Estado Sólido/uso terapéutico , Falla de Prótesis , Mallas Quirúrgicas/efectos adversos , Cistoscopía , Remoción de Dispositivos/instrumentación , Migración de Cuerpo Extraño/complicaciones , Migración de Cuerpo Extraño/diagnóstico , Hematuria/diagnóstico , Hematuria/etiología , Hematuria/cirugía , Hernia Inguinal/cirugía , Herniorrafia/instrumentación , Humanos , Síntomas del Sistema Urinario Inferior/diagnóstico , Síntomas del Sistema Urinario Inferior/etiología , Síntomas del Sistema Urinario Inferior/cirugía , Masculino , Persona de Mediana Edad , Tomografía Computarizada por Rayos X , Ultrasonografía , Vejiga Urinaria/diagnóstico por imagen , Vejiga Urinaria/cirugía
17.
Contraception ; 102(6): 424-427, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-32687911

RESUMEN

OBJECTIVE: Long-acting reversible contraceptives (LARCs) such as subdermal implants and intrauterine devices are promoted and increasingly used worldwide. Hence, in the light of this we also need to ensure easy access to the reversibility, i.e. emphasise the R in LARC. Our overall aim is to develop a device to facilitate implant removals. We evaluated the safety and performance of the two initial field prototypes where the main outcome was percentage of successful fixations and secondary outcomes were percentage of successful removals without the use of additional tools, duration of the procedure, satisfaction and adverse events. STUDY DESIGN: We performed a feasibility study including 41 subjects. RESULTS: We estimated a fixation rate of 35/41 (85%) and an overall removal rate of 24/41 (59%). Further, we measured that the median time for removals was 80 s and that subjects and operators were satisfied with the procedure. We recorded adverse events such as bruising and superficial abrasions. CONCLUSIONS: The device demonstrated a successful fixation rate, however, the removal rate will need to be further improved. IMPLICATIONS: This feasibility study shows that the device has potential and further research is needed to modify and optimize the device.


Asunto(s)
Anticonceptivos Femeninos , Remoción de Dispositivos/instrumentación , Implantes de Medicamentos , Dispositivos Intrauterinos , Adolescente , Adulto , Estudios de Factibilidad , Femenino , Humanos , Suecia , Adulto Joven
18.
JBJS Case Connect ; 10(2): e19.00542, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32649146

RESUMEN

CASE: A 45-year old man presented with a right open tibial fracture with a prominent, fixed deformity because of a retained right tibial intramedullary nail from a previous tibial fracture. After multiple futile intraoperative attempts to extract the bent nail, it was finally sectioned using an industrial drill bit that permitted its removal and revision tibial nailing. CONCLUSIONS: A tibial fracture resulting in a retained, bent nail presents unique challenges for nail extraction and subsequent exchange nailing. Failed implant removal can be limited by the equipment available in the operating theater. In this setting, the judicious use of inexpensive industrial materials and instruments may be effective in select cases.


Asunto(s)
Clavos Ortopédicos , Remoción de Dispositivos/instrumentación , Fracturas Abiertas/diagnóstico por imagen , Lesiones de Repetición/diagnóstico por imagen , Fracturas de la Tibia/diagnóstico por imagen , Remoción de Dispositivos/economía , Peroné/lesiones , Fijación Intramedular de Fracturas , Fracturas Abiertas/cirugía , Humanos , Masculino , Persona de Mediana Edad , Radiografía , Lesiones de Repetición/cirugía , Fracturas de la Tibia/cirugía
19.
J Neurosurg ; 134(5): 1569-1577, 2020 Jun 05.
Artículo en Inglés | MEDLINE | ID: mdl-32502991

RESUMEN

OBJECTIVE: The RECO flow restoration (FR) device is a new stent retriever designed for rapid flow restoration in acute ischemic stroke (AIS) caused by large vessel occlusion (LVO). Here, the authors compared the efficacy and safety of the RECO device with the predicate Solitaire FR stent retriever. METHODS: The RECO Flow Restoration Device Versus Solitaire FR With the Intention for Thrombectomy Study (REDIRECT) was a multicenter, prospective, open randomized controlled trial. Patients with acute LVO at 7 Chinese stroke centers participated in the study. The primary efficacy endpoint was defined as a modified thrombolysis in cerebral infarction (mTICI) reperfusion grade ≥ 2 within three passes. The primary safety endpoint comprised any serious adverse device effect, symptomatic intracerebral hemorrhage (sICH), and any serious adverse event (SAE; defined as cerebral palsy or death) within 24 hours after the procedure. The secondary efficacy endpoints consisted of functional independence (modified Rankin Scale score 0-2), procedure duration, and 90-day all-cause mortality. RESULTS: Between January 2014 and August 2016, 67 patients were randomly allocated to the RECO group and 69 patients to the Solitaire FR group. The primary efficacy endpoint (mTICI grade ≥ 2 within three passes) was similar in the two treatment groups (91% vs 87%, respectively, p = 0.5861), and the rate of reperfusion with an mTICI grade 2b/3 was 87% versus 75% (p = 0.1272). There were no serious adverse device effects in any patient. The rates of sICH (1.5% vs 7.2%, p = 0.1027) and SAEs (6.0% vs 1.4%, p = 0.2050) within 24 hours after the procedure were similar in the two treatment groups. There was no significant difference in the rate of functional independence (63% vs 46%, p = 0.0609) or 90-day all-cause mortality (13% vs 23%, p = 0.1848) or in procedure duration (85.39 ± 47.01 vs 89.94 ± 53.34 minutes, p = 0.5986) between the two groups. CONCLUSIONS: The RECO stent retriever is effective and safe as a mechanical thrombectomy device for AIS due to LVO. Clinical trial registration no.: NCT01983644 (clinicaltrials.gov).


Asunto(s)
Isquemia Encefálica/cirugía , Trastornos Cerebrovasculares/complicaciones , Trombolisis Mecánica/instrumentación , Anciano , Daño Encefálico Crónico/etiología , Daño Encefálico Crónico/prevención & control , Isquemia Encefálica/etiología , Cateterismo , Angiografía Cerebral , Hemorragia Cerebral/etiología , China , Remoción de Dispositivos/instrumentación , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Stents
20.
J Minim Invasive Gynecol ; 27(7): 1631-1635, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32540499

RESUMEN

To trial the use of a novel endoscopic robot that functions using concentric tube robots, enabling 2-handed surgery in small spaces, in a bioengineering laboratory. This was a feasibility study of the endoscopic robot for hysteroscopic applications, including removal of a simulated endometrial polyp. The endoscopic robot was successfully used to resect a simulated endometrial polyp from a porcine uterine tissue model in a fluid environment. The potential advantages of this platform to the surgeon may include improved exposure, finer dissection capability, and use of a 2-handed surgical technique. Further study regarding the safe, efficient, and cost-effective use of the endoscopic robot in gynecology is needed.


Asunto(s)
Endoscopía/instrumentación , Histeroscopía/instrumentación , Invenciones , Procedimientos Quirúrgicos Robotizados/instrumentación , Robótica/instrumentación , Animales , Remoción de Dispositivos/instrumentación , Remoción de Dispositivos/métodos , Endoscopía/métodos , Estudios de Factibilidad , Femenino , Ginatresia/cirugía , Humanos , Histeroscopía/métodos , Dispositivos Intrauterinos , Modelos Animales , Pólipos/cirugía , Procedimientos Quirúrgicos Robotizados/métodos , Robótica/métodos , Porcinos , Enfermedades Uterinas/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA