Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 27.745
Filtrar
1.
J Adhes Dent ; 26(1): 135-145, 2024 Jan 15.
Artículo en Inglés | MEDLINE | ID: mdl-38771025

RESUMEN

PURPOSE: To measure zirconia-to-zirconia microtensile bond strength (µTBS) using composite cements with and without primer. MATERIALS AND METHODS: Two Initial Zirconia UHT (GC) sticks (1.8x1.8x5.0 mm) were bonded using four cements with and without their respective manufacturer's primer/adhesive (G-CEM ONE [GOne] and G-Multi Primer, GC; Panavia V5 [Pv5]), and Panavia SA Cement Universal [PSAu], and Clearfil Ceramic Plus, Kuraray Noritake; RelyX Universal (RXu) and Scotchbond Universal Plus [SBUp], 3M Oral Care). Specimens were trimmed to an hour-glass shaped specimen whose isthmus is circular in cross-section. After 1-week water storage, the specimens were either tested immediately (1-week µTBS) or first subjected to 50,000 thermocycles (50kTC-aged µTBS). The fracture mode was categorized as either adhesive interfacial failure, cohesive failure in composite cement, or mixed failure, followed by SEM fracture analysis of selected specimens. Data were analyzed using linear mixed-effects statistics (α = 0.05; variables: composite cement, primer/adhesive application, aging). RESULTS: The statistical analysis revealed no significant differences with aging (p = 0.3662). No significant difference in µTBS with/without primer and aging was recorded for GOne and PSAu. A significantly higher µTBS was recorded for Pv5 and RXu when applied with their respective primer/adhesive. Comparing the four composite cements when they were applied in the manner that resulted in their best performance, a significant difference in 50kTC-aged µTBS was found for PSAu compared to Pv5 and RXu. A significant decrease in µTBS upon 50kTC aging was only recorded for RXu in combination with SBUp. CONCLUSION: Adequate bonding to zirconia requires the functional monomer 10-MDP either contained in the composite cement, in which case a separate 10-MDP primer is no longer needed, or in the separately applied primer/adhesive.


Asunto(s)
Resinas Compuestas , Recubrimiento Dental Adhesivo , Ensayo de Materiales , Metacrilatos , Cementos de Resina , Resistencia a la Tracción , Circonio , Circonio/química , Cementos de Resina/química , Resinas Compuestas/química , Metacrilatos/química , Cementos Dentales/química , Cerámica/química , Análisis del Estrés Dental , Humanos , Factores de Tiempo , Agua/química , Temperatura , Porcelana Dental/química , Propiedades de Superficie , Materiales Dentales/química , Cementos de Ionómero Vítreo
2.
Biomed Mater ; 19(4)2024 May 21.
Artículo en Inglés | MEDLINE | ID: mdl-38729187

RESUMEN

Bundles of engineered collagen microfibers are promising synthetic tendons as substitutes for autogenous grafts. The purpose of this study was to develop high-speed and continuous spinning of collagen microfibers that involves stretching of collagen stream. Our study revealed the 'critical fibrillogenesis concentration (CFC)' of neutralized collagen solutions, which is defined as the upper limit of the collagen concentration at which neutralized collagen molecules remain stable as long as they are cooled (⩽10 °C). Neutralized collagen solutions at collagen concentrations slightly below the CFC formed cord-like collagen gels comprising longitudinally aligned fibrils when extruded from nozzles into an ethanol bath. Dry collagen microfibers with a controlled diameter ranging from 122 ± 2-31.2 ± 1.7 µm can be spun from the cord-like gels using nozzles of various sizes. The spinning process was improved by including stretching of collagen stream to further reduce diameter and increase linear velocity. We extruded a collagen solution through a 182 µm diameter nozzle while simultaneously stretching it in an ethanol bath during gelation and fiber formation. This process resembles the stretching of a melted thermoplastic resin because it solidifies during melt spinning. The mechanical properties of the stretched collagen microfibers were comparable to the highest literature values obtained using microfluidic wet spinning, as they exhibited longitudinally aligned fibrils both on their surface and in their core. Previous wet spinning methods were unable to generate collagen microfibers with a consistent tendon-like fibrillar arrangement throughout the samples. Although the tangent modulus (137 ± 7 MPa) and stress at break of the swollen bundles of stretched microfibers (13.8 ± 1.9 MPa) were lower than those of human anterior cruciate ligament, they were within the same order of magnitude. We developed a spinning technique that produces narrow collagen microfibers with a tendon-like arrangement that can serve as artificial fiber units for collagen-based synthetic tendons.


Asunto(s)
Colágeno , Ensayo de Materiales , Tendones , Ingeniería de Tejidos , Colágeno/química , Ingeniería de Tejidos/métodos , Animales , Materiales Biocompatibles/química , Humanos , Resistencia a la Tracción , Estrés Mecánico , Andamios del Tejido/química
3.
PLoS One ; 19(5): e0301142, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38718088

RESUMEN

Steel cord materials were found to have internal porous microstructures and complex fluid flow properties. However, current studies have rarely reported the transport behavior of steel cord materials from a microscopic viewpoint. The computed tomography (CT) scanning technology and lattice Boltzmann method (LBM) were used in this study to reconstruct and compare the real three-dimensional (3D) pore structures and fluid flow in the original and tensile (by loading 800 N force) steel cord samples. The pore-scale LBM results showed that fluid velocities increased as displacement differential pressure increased in both the original and tensile steel cord samples, but with two different critical values of 3.3273 Pa and 2.6122 Pa, respectively. The original steel cord sample had higher maximal and average seepage velocities at the 1/2 sections of 3D construction images than the tensile steel cord sample. These phenomena should be attributed to the fact that when the original steel cord sample was stretched, its porosity decreased, pore radius increased, flow channel connectivity improved, and thus flow velocity increased. Moreover, when the internal porosity of tensile steel cord sample was increased by 1 time, lead the maximum velocity to increase by 1.52 times, and the average velocity was increased by 1.66 times. Furthermore, when the density range was determined to be 0-38, the pore phase showed the best consistency with the segmentation area. Depending on the Zou-He Boundary and Regularized Boundary, the relative error of simulated average velocities was only 0.2602 percent.


Asunto(s)
Acero , Acero/química , Porosidad , Resistencia a la Tracción , Hidrodinámica , Tomografía Computarizada por Rayos X
4.
Clin Oral Investig ; 28(6): 305, 2024 May 09.
Artículo en Inglés | MEDLINE | ID: mdl-38722356

RESUMEN

OBJECTIVE: To evaluate the ability of the water glass treatment to penetrate zirconia and improve the bond strength of resin cement. MATERIAL AND METHODS: Water glass was applied to zirconia specimens, which were then sintered. The specimens were divided into water-glass-treated and untreated zirconia (control) groups. The surface properties of the water-glass-treated specimens were evaluated using surface roughness and electron probe micro-analyser (EPMA) analysis. A resin cement was used to evaluate the tensile bond strength, with2 and without a silane-containing primer. After 24 h in water storage at 37 °C and thermal cycling, the bond strengths were statistically evaluated with t-test, and the fracture surfaces were observed using SEM. RESULTS: The water glass treatment slightly increased the surface roughness of the zirconia specimens, and the EPMA analysis detected the water glass penetration to be 50 µm below the zirconia surface. The application of primer improved the tensile bond strength in all groups. After 24 h, the water-glass-treated zirconia exhibited a tensile strength of 24.8 ± 5.5 MPa, which was significantly higher than that of the control zirconia (17.6 ± 3.5 MPa) (p < 0.05). After thermal cycling, the water-glass-treated zirconia showed significantly higher tensile strength than the control zirconia. The fracture surface morphology was mainly an adhesive pattern, whereas resin cement residue was occasionally detected on the water-glass-treated zirconia surfaces. CONCLUSION: The water glass treatment resulted in the formation of a stable silica phase on the zirconia surface. This process enabled silane coupling to the zirconia and improved the adhesion of the resin cement.


Asunto(s)
Recubrimiento Dental Adhesivo , Vidrio , Ensayo de Materiales , Cementos de Resina , Silanos , Propiedades de Superficie , Resistencia a la Tracción , Agua , Circonio , Circonio/química , Cementos de Resina/química , Silanos/química , Agua/química , Recubrimiento Dental Adhesivo/métodos , Vidrio/química , Microscopía Electrónica de Rastreo , Análisis del Estrés Dental
5.
Molecules ; 29(9)2024 Apr 29.
Artículo en Inglés | MEDLINE | ID: mdl-38731542

RESUMEN

Bilayer electrospun fibers aimed to be used for skin tissue engineering applications were fabricated for enhanced cell attachment and proliferation. Different ratios of PHBV-PLLA (70:30, 80:20, and 90:10 w/w) blends were electrospun on previously formed electrospun PHBV membranes to produce their bilayers. The fabricated electrospun membranes were characterized with FTIR, which conformed to the characteristic peaks assigned for both PHBV and PLLA. The surface morphology was evaluated using SEM analysis that showed random fibers with porous morphology. The fiber diameter and pore size were measured in the range of 0.7 ± 0.1 µm and 1.9 ± 0.2 µm, respectively. The tensile properties of the bilayers were determined using an electrodynamic testing system. Bilayers had higher elongation at break (44.45%) compared to the monolayers (28.41%) and improved ultimate tensile strength (7.940 MPa) compared to the PHBV monolayer (2.450 MPa). In vitro cytotoxicity of each of the scaffolds was determined via culturing MC3T3 (pre-osteoblastic cell line) on the membranes. Proliferation was evaluated using the Alamar Blue assay on days 3, 7, and 14, respectively. SEM images of cells cultured on membranes were taken in addition to bright field imaging to visually show cell attachment. Fluorescent nuclear staining performed with DAPI was imaged with an inverted fluorescent microscope. The fabricated bilayer shows high mechanical strength as well as biocompatibility with good cell proliferation and cell attachment, showing potential for skin substitute applications.


Asunto(s)
Materiales Biocompatibles , Proliferación Celular , Poliésteres , Piel , Ingeniería de Tejidos , Andamios del Tejido , Ingeniería de Tejidos/métodos , Materiales Biocompatibles/química , Materiales Biocompatibles/farmacología , Poliésteres/química , Animales , Ratones , Proliferación Celular/efectos de los fármacos , Andamios del Tejido/química , Resistencia a la Tracción , Membranas Artificiales , Línea Celular , Ensayo de Materiales , Polímeros/química , Adhesión Celular/efectos de los fármacos
6.
Sci Rep ; 14(1): 10825, 2024 05 11.
Artículo en Inglés | MEDLINE | ID: mdl-38734808

RESUMEN

This study developed a kind of PEG-crosslinked O-carboxymethyl chitosan (O-CMC-PEG) with various PEG content for food packaging. The crosslinking agent of isocyanate-terminated PEG was firstly synthesized by a simple condensation reaction between PEG and excess diisocyanate, then the crosslink between O-carboxymethyl chitosan (O-CMC) and crosslinking agent occurred under mild conditions to produce O-CMC-PEG with a crosslinked structure linked by urea bonds. FT-IR and 1H NMR techniques were utilized to confirm the chemical structures of the crosslinking agent and O-CMC-PEGs. Extensive research was conducted to investigate the impact of the PEG content (or crosslinking degree) on the physicochemical characteristics of the casted O-CMC-PEG films. The results illuminated that crosslinking and components compatibility could improve their tensile features and water vapor barrier performance, while high PEG content played the inverse effects due to the microphase separation between PEG and O-CMC segments. The in vitro degradation rate and water sensitivity primarily depended on the crosslinking degree in comparison with the PEG content. Furthermore, caused by the remaining -NH2 groups of O-CMC, the films demonstrated antibacterial activity against Escherichia coli and Staphylococcus aureus. When the PEG content was 6% (medium crosslinking degree), the prepared O-CMC-PEG-6% film possessed optimal tensile features, high water resistance, appropriate degradation rate, low water vapor transmission rate and fine broad-spectrum antibacterial capacity, manifesting a great potential for application in food packaging to extend the shelf life.


Asunto(s)
Antibacterianos , Quitosano , Escherichia coli , Embalaje de Alimentos , Polietilenglicoles , Quitosano/química , Quitosano/análogos & derivados , Quitosano/farmacología , Embalaje de Alimentos/métodos , Antibacterianos/química , Antibacterianos/farmacología , Polietilenglicoles/química , Escherichia coli/efectos de los fármacos , Reactivos de Enlaces Cruzados/química , Espectroscopía Infrarroja por Transformada de Fourier , Staphylococcus aureus/efectos de los fármacos , Pruebas de Sensibilidad Microbiana , Resistencia a la Tracción
7.
PLoS One ; 19(5): e0302778, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38713687

RESUMEN

INTRODUCTION: Magnetic resonance-guided focused ultrasound (MRgFUS) has been demonstrated to be able to thermally ablate tendons with the aim to non-invasively disrupt tendon contractures in the clinical setting. However, the biomechanical changes of tendons permitting this disrupting is poorly understood. We aim to obtain a dose-dependent biomechanical response of tendons following magnetic resonance-guided focused ultrasound (MRgFUS) thermal ablation. METHODS: Ex vivo porcine tendons (n = 72) were embedded in an agar phantom and randomly assigned to 12 groups based on MRgFUS treatment. The treatment time was 10, 20, or 30s, and the applied acoustic power was 25, 50, 75, or 100W. Following each MRgFUS treatment, tendons underwent biomechanical tensile testing on an Instron machine, which calculated stress-strain curves during tendon elongation. Rupture rate, maximum treatment temperature, Young's modulus and ultimate strength were analyzed for each treatment energy. RESULTS: The study revealed a dose-dependent response, with tendons rupturing in over 50% of cases when energy delivery exceeded 1000J and 100% disruption at energy levels beyond 2000J. The achieved temperatures during MRgFUS were directly proportional to energy delivery. The highest recorded temperature was 56.8°C ± 9.34 (3000J), while the lowest recorded temperate was 18.6°C ± 0.6 (control). The Young's modulus was highest in the control group (47.3 MPa ± 6.5) and lowest in the 3000J group (13.2 MPa ± 5.9). There was no statistically significant difference in ultimate strength between treatment groups. CONCLUSION: This study establishes crucial thresholds for reliable and repeatable disruption of tendons, laying the groundwork for future in vivo optimization. The findings prompt further exploration of MRgFUS as a non-invasive modality for tendon disruption, offering hope for improved outcomes in patients with musculotendinous contractures.


Asunto(s)
Ultrasonido Enfocado de Alta Intensidad de Ablación , Tendones , Animales , Porcinos , Tendones/cirugía , Tendones/fisiología , Tendones/diagnóstico por imagen , Fenómenos Biomecánicos , Ultrasonido Enfocado de Alta Intensidad de Ablación/métodos , Imagen por Resonancia Magnética/métodos , Resistencia a la Tracción , Módulo de Elasticidad
8.
Int J Mol Sci ; 25(9)2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38731949

RESUMEN

To enrich the properties of polylactic acid (PLA)-based composite films and improve the base degradability, in this study, a certain amount of poly(propylene carbonate) (PPC) was added to PLA-based composite films, and PLA/PPC-based composite films were prepared by melt blending and hot-press molding. The effects of the introduction of PPC on the composite films were analyzed through in-depth studies on mechanical properties, water vapor and oxygen transmission rates, thermal analysis, compost degradability, and bacterial inhibition properties of the composite films. When the introduction ratio coefficient of PPC was 30%, the tensile strength of the composite film increased by 19.68%, the water vapor transmission coefficient decreased by 14.43%, and the oxygen transmission coefficient decreased by 18.31% compared to that of the composite film without PPC, the cold crystallization temperature of the composite film increased gradually from 96.9 °C to 104.8 °C, and PPC improved the crystallization ability of composite film. The degradation rate of the composite film with PPC increased significantly compared to the previous one, and the degradation rate increased with the increase in the PPC content. The degradation rate was 49.85% and 46.22% faster on average than that of the composite film without PPC when the degradation was carried out over 40 and 80 days; the composite film had certain inhibition, and the maximum diameter of the inhibition circle was 2.42 cm. This study provides a strategy for the development of PLA-based biodegradable laminates, which can promote the application of PLA-based laminates in food packaging.


Asunto(s)
Poliésteres , Propano/análogos & derivados , Resistencia a la Tracción , Poliésteres/química , Polipropilenos/química , Embalaje de Alimentos/métodos , Vapor , Polímeros/química , Antibacterianos/química , Antibacterianos/farmacología , Temperatura
9.
Carbohydr Polym ; 337: 122112, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38710545

RESUMEN

The growing concerns on environmental pollution and sustainability have raised the interest on the development of functional biobased materials for different applications, including food packaging, as an alternative to the fossil resources-based counterparts, currently available in the market. In this work, functional wood inspired biopolymeric nanocomposite films were prepared by solvent casting of suspensions containing commercial beechwood xylans, cellulose nanofibers (CNF) and lignosulfonates (magnesium or sodium), in a proportion of 2:5:3 wt%, respectively. All films presented good homogeneity, translucency, and thermal stability up to 153 °C. The incorporation of CNF into the xylan/lignosulfonates matrix provided good mechanical properties to the films (Young's modulus between 1.08 and 3.79 GPa and tensile strength between 12.75 and 14.02 MPa). The presence of lignosulfonates imparted the films with antioxidant capacity (DPPH radical scavenging activity from 71.6 to 82.4 %) and UV barrier properties (transmittance ≤19.1 % (200-400 nm)). Moreover, the films obtained are able to successfully delay the browning of packaged fruit stored over 7 days at 4 °C. Overall, the obtained results show the potential of using low-cost and eco-friendly resources for the development of sustainable active food packaging materials.


Asunto(s)
Celulosa , Embalaje de Alimentos , Lignina , Lignina/análogos & derivados , Nanocompuestos , Nanofibras , Resistencia a la Tracción , Madera , Xilanos , Embalaje de Alimentos/métodos , Lignina/química , Nanocompuestos/química , Celulosa/química , Celulosa/análogos & derivados , Madera/química , Nanofibras/química , Xilanos/química , Antioxidantes/química , Frutas/química
10.
Med Eng Phys ; 127: 104158, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38692761

RESUMEN

BACKGROUND: The intervertebral disc exhibits not only strain rate dependence (viscoelasticity), but also significant asymmetry under tensile and compressive loads, which is of great significance for understanding the mechanism of lumbar disc injury under physiological loads. OBJECTIVE: In this study, the strain rate sensitive and tension-compression asymmetry of the intervertebral disc were analyzed by experiments and constitutive equation. METHOD: The Sheep intervertebral disc samples were divided into three groups, in order to test the strain rate sensitive mechanical behavior, and the internal displacement as well as pressure distribution. RESULTS: The tensile stiffness is one order of magnitude smaller than the compression stiffness, and the logarithm of the elastic modulus is approximately linear with the logarithm of the strain rate, showing obvious tension-compression asymmetry and rate-related characteristics. In addition, the sensitivity to the strain rate is the same under these two loading conditions. The stress-strain curves of unloading and loading usually do not coincide, and form a Mullins effect hysteresis loop. The radial displacement distribution is opposite between the anterior and posterior region, which is consistent with the stress distribution. By introducing the damage factor into ZWT constitutive equation, the rate-dependent viscoelastic and weakening behavior of the intervertebral disc can be well described.


Asunto(s)
Fuerza Compresiva , Disco Intervertebral , Estrés Mecánico , Animales , Disco Intervertebral/fisiología , Ovinos , Fenómenos Biomecánicos , Resistencia a la Tracción , Soporte de Peso , Elasticidad
11.
AAPS PharmSciTech ; 25(5): 101, 2024 May 07.
Artículo en Inglés | MEDLINE | ID: mdl-38714629

RESUMEN

BACKGROUND: Niacin, an established therapeutic for dyslipidemia, is hindered by its propensity to induce significant cutaneous flushing when administered orally in its unmodified state, thereby constraining its clinical utility. OBJECTIVE: This study aimed to fabricate, characterize, and assess the in-vitro and in-vivo effectiveness of niacin-loaded polymeric films (NLPFs) comprised of carboxymethyl tamarind seed polysaccharide. The primary objective was to mitigate the flushing-related side effects associated with oral niacin administration. METHODS: NLPFs were synthesized using the solvent casting method and subsequently subjected to characterization, including assessments of tensile strength, moisture uptake, thickness, and folding endurance. Surface characteristics were analyzed using a surface profiler and scanning electron microscopy (SEM). Potential interactions between niacin and the polysaccharide core were investigated through X-ray diffraction experiments (XRD) and Fourier transform infrared spectroscopy (FTIR). The viscoelastic properties of the films were explored using a Rheometer. In-vitro assessments included drug release studies, swelling behavior assays, and antioxidant assays. In-vivo efficacy was evaluated through skin permeation assays, skin irritation assays, and histopathological analyses. RESULTS: NLPFs exhibited a smooth texture with favorable tensile strength and moisture absorption capabilities. Niacin demonstrated interaction with the polysaccharide core, rendering the films amorphous. The films displayed slow and sustained drug release, exceptional antioxidant properties, optimal swelling behavior, and viscoelastic characteristics. Furthermore, the films exhibited biocompatibility and non-toxicity towards skin cells. CONCLUSION: NLPFs emerged as promising carrier systems for the therapeutic transdermal delivery of niacin, effectively mitigating its flushing-associated adverse effects.


Asunto(s)
Administración Cutánea , Liberación de Fármacos , Niacina , Polisacáridos , Ratas Wistar , Absorción Cutánea , Piel , Animales , Ratas , Niacina/administración & dosificación , Niacina/química , Niacina/farmacología , Polisacáridos/química , Polisacáridos/administración & dosificación , Polisacáridos/farmacología , Piel/metabolismo , Piel/efectos de los fármacos , Absorción Cutánea/efectos de los fármacos , Rubor/inducido químicamente , Resistencia a la Tracción , Masculino , Sistemas de Liberación de Medicamentos/métodos , Tamarindus/química , Polímeros/química
12.
J Appl Biomater Funct Mater ; 22: 22808000231214359, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38702952

RESUMEN

Exploring high strength materials with a higher concentration of reinforcements in the alloy proves to be a challenging task. This research has explored magnesium-based composites (AZ31B alloy) with tungsten carbide reinforcements, enhancing strength for medical joint replacements via league championship optimisation. The primary objective is to enhance medical joint replacement biomaterials employing magnesium-based composites, emphasising the AZ31B alloy with tungsten carbide reinforcements. The stir casting method is utilised in the manufacture of magnesium matrix composites (MMCs), including varied percentages of tungsten carbide (WC). The mechanical characteristics, such as micro-hardness, tensile strength, and yield strength, have been assessed and compared with computational simulations. The wear studies have been carried out to analyse the tribological behaviour of the composites. Additionally, this study investigates the prediction of stress and the distribution of forces inside bone and joint structures, therefore offering significant contributions to the field of biomedical research. This research contemplates the use of magnesium-based MMCs for the discovery of biomaterials suitable for medical joint replacement. The study focuses on the magnesium alloy AZ31B, with particles ranging in size from 40 to 60 microns used as the matrix material. Moreover, the outcomes have revealed that when combined with MMCs based on AZ31B-magnesium matrix, the WC particle emerges as highly effective reinforcements for the fabrication of lightweight, high-strength biomedical composites. This study uses the league championship optimisation (LCO) approach to identify critical variables impacting the synthesis of Mg MMCs from an AZ31B-based magnesium alloy. The scanning electron microscopy (SEM) images are meticulously analysed to depict the dispersion of WC particulates and the interface among the magnesium (Mg) matrix and WC reinforcement. The SEM analysis has explored the mechanisms underlying particle pull-out, the characteristics of inter-particle zones, and the influence of the AZ31B matrix on the enhancement of the mechanical characteristics of the composites. The application of finite element analysis (FEA) is being used in order to make predictions regarding the distribution of stress and the interactions of forces within the model of the hip joint. This study has compared the physico-mechanical and tribological characteristics of WC to distinct combinations of 0%, 5%, 10% and 15%, and its impact on the performance improvements. SEM analysis has confirmed the findings' improved strength and hardness, particularly when 10%-15% of WC was incorporated. Following the incorporation of 10% of WC particles within Mg-alloy matrix, the outcomes of the study has exhibited enhanced strength and hardness, which furthermore has been evident by utilising SEM analysis. Using ANSYS, structural deformation and stress levels are predicted, along with strength characteristics such as additional hardness of 71 HRC, tensile strength of 140-150 MPa, and yield strength closer to 100-110 MPa. The simulations yield significant insights into the behaviour of the joint under various loading conditions, thus enhancing the study's significance in biomedical environments.


Asunto(s)
Aleaciones , Magnesio , Ensayo de Materiales , Aleaciones/química , Magnesio/química , Compuestos de Tungsteno/química , Materiales Biocompatibles/química , Humanos , Resistencia a la Tracción , Articulación de la Cadera
13.
Eur J Med Res ; 29(1): 264, 2024 May 03.
Artículo en Inglés | MEDLINE | ID: mdl-38698476

RESUMEN

BACKGROUND: The fundamental prerequisite for prognostically favorable postoperative results of peripheral nerve repair is stable neurorrhaphy without interruption and gap formation. METHODS: This study evaluates 60 neurorrhaphies on femoral chicken nerves in terms of the procedure and the biomechanical properties. Sutured neurorrhaphies (n = 15) served as control and three sutureless adhesive-based nerve repair techniques: Fibrin glue (n = 15), Histoacryl glue (n = 15), and the novel polyurethane adhesive VIVO (n = 15). Tensile and elongation tests of neurorrhaphies were performed on a tensile testing machine at a displacement rate of 20 mm/min until failure. The maximum tensile force and elongation were recorded. RESULTS: All adhesive-based neurorrhaphies were significant faster in preparation compared to sutured anastomoses (p < 0.001). Neurorrhaphies by sutured (102.8 [cN]; p < 0.001), Histoacryl (91.5 [cN]; p < 0.001) and VIVO (45.47 [cN]; p < 0.05) withstood significant higher longitudinal tensile forces compared to fibrin glue (10.55 [cN]). VIVO, with △L/L0 of 6.96 [%], showed significantly higher elongation (p < 0.001) compared to neurorrhaphy using fibrin glue. CONCLUSION: Within the limitations of an in vitro study the adhesive-based neurorrhaphy technique with VIVO and Histoacryl have the biomechanical potential to offer alternatives to sutured neuroanastomosis because of their stability, and faster handling. Further in vivo studies are required to evaluate functional outcomes and confirm safety.


Asunto(s)
Anastomosis Quirúrgica , Pollos , Resistencia a la Tracción , Animales , Anastomosis Quirúrgica/métodos , Fenómenos Biomecánicos , Adhesivos Tisulares/farmacología , Adhesivo de Tejido de Fibrina/farmacología , Nervios Periféricos/cirugía , Nervios Periféricos/fisiología , Adhesivos , Procedimientos Neuroquirúrgicos/métodos
14.
Am J Dent ; 37(2): 71-77, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38704849

RESUMEN

PURPOSE: To investigate the effect of painless low-power Er:YAG laser irradiation of conventional and polymer-infiltrated ceramic network (PICN) type CAD-CAM resin-based composites (RBCs) on resin bonding. METHODS: An Er:YAG laser system, phosphoric acid etchant, universal adhesive, RBC, and two types of CAD-CAM RBC block were used. Microtensile bond strength, fracture mode, scanning electron microscopy (SEM) observations of bonding interfaces and CAD-CAM surfaces, and surface roughness of ground and pretreated surfaces were investigated. As pretreatment methods, low-power Er:YAG laser irradiation and air-abrasion with alumina particles were used. RESULTS: The effect of low-power Er:YAG laser irradiation of CAD-CAM RBCs on bonding to repair resin varied depending on the type of CAD-CAM RBCs. CLINICAL SIGNIFICANCE: The low-power Er:YAG laser irradiation of the conventional CAD-CAM RBCs was shown to be effective as a surface pretreatment for resin bonding, while the laser irradiation of PICN-type CAD-CAM RBCs was not effective.


Asunto(s)
Resinas Compuestas , Diseño Asistido por Computadora , Recubrimiento Dental Adhesivo , Láseres de Estado Sólido , Microscopía Electrónica de Rastreo , Propiedades de Superficie , Resinas Compuestas/química , Resistencia a la Tracción , Ensayo de Materiales , Humanos , Cerámica/química , Grabado Ácido Dental
15.
PLoS One ; 19(5): e0303645, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38771843

RESUMEN

The corrosion resistance of FRP-reinforced ordinary concrete members under the combined action of harsh environments (i.e., alkaline or acidic solutions, salt solutions) and freeze-thaw cycles is still unclear. To study the mechanical and apparent deterioration of carbon/basalt/glass/aramid fiber cloth reinforced concrete under chemical and freeze-thaw coupling. Plain concrete blocks and FRP-bonded concrete blocks were fabricated. The tensile properties of the FRP sheet and epoxy resin sheet before and after chemical freezing, the compressive strength of the FRP reinforced test block, and the bending capacity of the prismatic test block pasted with FRP on the prefabricated crack side were tested. The deterioration mechanism of the test block was analyzed through the change of surface photos. Based on the experimental data, the Lam-Teng constitutive model of concrete reinforced by alkali-freeze coupling FRP is modified. The results indicate that, in terms of apparent properties, with the increase in the duration of chemical freeze-thaw erosion, the surface of epoxy resin sheets exhibits an increase in pores, along with the emergence of small cracks and wrinkles. The texture of FRP sheets becomes blurred, and cracks and wrinkles appear on the surface. In terms of failure modes, as the number of chemical coupling erosion cycles increases, the location of failure in epoxy resin sheets becomes uncertain, and the failure plane tilts towards the direction of the applied load. The failure mode of FRP sheets remains unchanged. However, the bonding strength between FRP sheets and concrete decreases, resulting in a weakened reinforcement effect. In terms of mechanical properties, FRP sheets undergo the most severe degradation in the coupled environment of acid freeze-thaw cycles. Among them, GFRP experiences the largest degradation in tensile strength, reaching up to 30.17%. In terms of tensile performance, the sheets rank from highest to lowest as follows: CFRP, BFRP, AFRP, and GFRP.As the duration of chemical freeze-coupled erosion increases, the loss rate of compressive strength for specimens bonded with CFRP is the smallest (9.62% in salt freeze-thaw environment), while the loss rate of bearing capacity is higher for specimens reinforced with GFRP (33.8% in acid freeze-thaw environment). In contrast, the loss rate of bearing capacity is lower for specimens reinforced with CFRP (13.6% in salt freeze-thaw environment), but still higher for specimens reinforced with GFRP (25.8% in acid freeze-thaw environment).


Asunto(s)
Materiales de Construcción , Congelación , Ensayo de Materiales , Resistencia a la Tracción , Materiales de Construcción/análisis , Fuerza Compresiva
16.
J Am Chem Soc ; 146(20): 13903-13913, 2024 May 22.
Artículo en Inglés | MEDLINE | ID: mdl-38721817

RESUMEN

Cohesive and interfacial adhesion energies are difficult to balance to obtain reversible adhesives with both high mechanical strength and high adhesion strength, although various methods have been extensively investigated. Here, a biocompatible citric acid/L-(-)-carnitine (CAC)-based ionic liquid was developed as a solvent to prepare tough and high adhesion strength ionogels for reversible engineered and biological adhesives. The prepared ionogels exhibited good mechanical properties, including tensile strength (14.4 MPa), Young's modulus (48.1 MPa), toughness (115.2 MJ m-3), and high adhesion strength on the glass substrate (24.4 MPa). Furthermore, the ionogels can form mechanically matched tough adhesion at the interface of wet biological tissues (interfacial toughness about 191 J m-2) and can be detached by saline solution on demand, thus extending potential applications in various clinical scenarios such as wound adhesion and nondestructive transfer of organs.


Asunto(s)
Materiales Biocompatibles , Ácido Cítrico , Geles , Materiales Biocompatibles/química , Materiales Biocompatibles/síntesis química , Ácido Cítrico/química , Geles/química , Carnitina/química , Líquidos Iónicos/química , Resistencia a la Tracción , Adhesivos/química
17.
Int J Artif Organs ; 47(5): 338-346, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38693724

RESUMEN

In the present study, porous silk fibroin sponges (SFS) were prepared using silk fibroin (SF), fish bone collagen (FBC), and olive oil (OO). The study investigates the potential use of using this sponge as skin tissue regeneration. The sponge was characterized for its physicochemical, mechanical, antimicrobial, and drug release properties. An in vitro study was carried out using human keratinocyte cell line (HaCaT). Biodegradation study using enzymatic method was carried out. The results showed that the mechanical properties such as tensile strength (23.40 ± 0.05 MPa), elongation at break (14.25 ± 0.02%), and water absorption (30.23 ± 0.01%) of the SFS were excellent, indicating promising performance. The 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide (MTT) assays proved the biocompatible nature of the SFS. The SFS exhibited outstanding antibacterial properties against E. coli (4.72 ± 0.05 mm) and S. aureus (4.98 ± 0.07 mm). The developed SFS promote a promising solution for skin tissue regeneration and wound dressing.


Asunto(s)
Antibacterianos , Colágeno , Fibroínas , Regeneración , Piel , Staphylococcus aureus , Andamios del Tejido , Cicatrización de Heridas , Fibroínas/química , Fibroínas/farmacología , Cicatrización de Heridas/efectos de los fármacos , Humanos , Colágeno/metabolismo , Animales , Regeneración/efectos de los fármacos , Antibacterianos/farmacología , Antibacterianos/administración & dosificación , Piel/efectos de los fármacos , Piel/metabolismo , Staphylococcus aureus/efectos de los fármacos , Células HaCaT , Escherichia coli/efectos de los fármacos , Queratinocitos/efectos de los fármacos , Aceite de Oliva , Huesos/efectos de los fármacos , Huesos/metabolismo , Peces , Resistencia a la Tracción , Porosidad , Materiales Biocompatibles , Línea Celular
18.
Int J Biol Macromol ; 268(Pt 1): 131464, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38702248

RESUMEN

Global concerns over environmental damage caused by non-biodegradable single-use packaging have sparked interest in developing biomaterials. The food packaging industry is a major contributor to non-degradable plastic waste. This study investigates the impact of incorporating different concentrations of polyvinyl alcohol (PVA) and yerba mate extract as a natural antioxidant into carboxymethyl cassava starch films to possibly use as active degradable packaging to enhance food shelf life. Films with starch and PVA blends (SP) at different ratios (SP radios of 100:0, 90:10, 80:20 and 70:30) with and without yerba mate extract (Y) were successfully produced through extrusion and thermoforming. The incorporation of up to 20 wt% PVA improved starch extrusion processing and enhanced film transparency. PVA played a crucial role in improving the hydrophobicity, tensile strength and flexibility of the starch films but led to a slight deceleration in their degradation in compost. In contrast, yerba mate extract contributed to better compost degradation of the blend films. Additionally, it provided antioxidant activity, particularly in hydrophilic and lipophilic food simulants, suggesting its potential to extend the shelf life of food products. Starch-PVA blend films with yerba mate extract emerged as a promising alternative for mechanically resistant and active food packaging.


Asunto(s)
Antioxidantes , Embalaje de Alimentos , Manihot , Extractos Vegetales , Alcohol Polivinílico , Almidón , Embalaje de Alimentos/métodos , Alcohol Polivinílico/química , Almidón/química , Almidón/análogos & derivados , Antioxidantes/química , Manihot/química , Extractos Vegetales/química , Ilex paraguariensis/química , Resistencia a la Tracción , Interacciones Hidrofóbicas e Hidrofílicas , Fenómenos Mecánicos
19.
AAPS PharmSciTech ; 25(5): 116, 2024 May 20.
Artículo en Inglés | MEDLINE | ID: mdl-38769223

RESUMEN

Oral dispersible films have received broad interest due to fast drug absorption and no first-path metabolism, leading to high bioavailability and better patient compliance. Saxagliptin (SXG) is an antidiabetic drug that undergoes first-path metabolism, resulting in a less active metabolite, so the development of SXG oral dispersible films (SXG-ODFs) improves SXG bioavailability. The formula optimisation included a response surface experimental design and the impact of three formulation factors, the type and concentration of polymer and plasticiser concentration on in-vitro disintegration time and folding endurance. Two optimised SXG-ODFs prepared using either polyvinyl alcohol (PVA) or hydroxypropyl methylcellulose were investigated. SXG-ODFs prepared with PVA demonstrated a superior rapid disintegration time, ranging from 17 to 890 s, with the fastest disintegration time recorded at 17 s. These short durations can be attributed to the hydrophilic nature of PVA, facilitating rapid hydration and disintegration upon contact with saliva. Additionally, PVA-based films displayed remarkable folding endurance, surpassing 200 folds without rupture, indicating flexibility and stability. The high tensile strength of PVA-based films further underscores their robust mechanical properties, with tensile strength values reaching up to 4.53 MPa. SXG exhibits a UV absorption wavelength of around 212 nm, posing challenges for traditional quantitative spectrophotometric analysis, so a polyaniline nanoparticles-based solid-contact screen-printed ion-selective electrode (SP-ISE) was employed for the determination of SXG release profile effectively in comparison to HPLC. SP-ISE showed a better real-time release profile of SXG-ODFs, and the optimised formula showed lower blood glucose levels than commercial tablets.


Asunto(s)
Adamantano , Compuestos de Anilina , Dipéptidos , Liberación de Fármacos , Nanopartículas , Alcohol Polivinílico , Adamantano/química , Adamantano/análogos & derivados , Dipéptidos/química , Dipéptidos/farmacocinética , Dipéptidos/administración & dosificación , Compuestos de Anilina/química , Nanopartículas/química , Administración Oral , Alcohol Polivinílico/química , Hipoglucemiantes/química , Hipoglucemiantes/administración & dosificación , Hipoglucemiantes/farmacocinética , Humanos , Derivados de la Hipromelosa/química , Resistencia a la Tracción , Química Farmacéutica/métodos , Disponibilidad Biológica , Solubilidad , Electrodos
20.
PLoS One ; 19(5): e0301216, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38743641

RESUMEN

Non-thermal atmospheric-pressure plasma (NTAPP) has been widely studied for clinical applications, e.g., disinfection, wound healing, cancer therapy, hemostasis, and bone regeneration. It is being revealed that the physical and chemical actions of plasma have enabled these clinical applications. Based on our previous report regarding plasma-stimulated bone regeneration, this study focused on Achilles tendon repair by NTAPP. This is the first study to reveal that exposure to NTAPP can accelerate Achilles tendon repair using a well-established Achilles tendon injury rat model. Histological evaluation using the Stoll's and histological scores showed a significant improvement at 2 and 4 weeks, with type I collagen content being substantial at the early time point of 2 weeks post-surgery. Notably, the replacement of type III collagen with type I collagen occurred more frequently in the plasma-treated groups at the early stage of repair. Tensile strength test results showed that the maximum breaking strength in the plasma-treated group at two weeks was significantly higher than that in the untreated group. Overall, our results indicate that a single event of NTAPP treatment during the surgery can contribute to an early recovery of an injured tendon.


Asunto(s)
Tendón Calcáneo , Gases em Plasma , Traumatismos de los Tendones , Cicatrización de Heridas , Animales , Tendón Calcáneo/lesiones , Ratas , Gases em Plasma/farmacología , Gases em Plasma/uso terapéutico , Cicatrización de Heridas/efectos de los fármacos , Traumatismos de los Tendones/terapia , Masculino , Helio/farmacología , Ratas Sprague-Dawley , Colágeno Tipo I/metabolismo , Resistencia a la Tracción , Presión Atmosférica , Colágeno Tipo III/metabolismo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA