Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.471
Filtrar
1.
Mikrochim Acta ; 191(5): 295, 2024 05 03.
Artículo en Inglés | MEDLINE | ID: mdl-38700804

RESUMEN

White blood cells (WBCs) are robust defenders during antigenic challenges and prime immune cell functioning indicators. High-purity WBC separation is vital for various clinical assays and disease diagnosis. Red blood cells (RBCs) are a major hindrance in WBC separation, constituting 1000 times the WBC population. The study showcases a low-cost micropump integrated microfluidic platform to provide highly purified WBCs for point-of-care testing. An integrated user-friendly microfluidic platform was designed to separate WBCs from finger-prick blood (⁓5 µL), employing an inertial focusing technique. We achieved an efficient WBC separation with 86% WBC purity and 99.99% RBC removal rate in less than 1 min. In addition, the microdevice allows lab-on-chip colorimetric evaluation of chronic granulomatous disease (CGD), a rare genetic disorder affecting globally. The assay duration, straight from separation to disease detection, requires only 20 min. Hence, the proposed microfluidic platform can further be implemented to streamline various clinical procedures involving WBCs in healthcare industries.


Asunto(s)
Separación Celular , Enfermedad Granulomatosa Crónica , Dispositivos Laboratorio en un Chip , Leucocitos , Técnicas Analíticas Microfluídicas , Humanos , Enfermedad Granulomatosa Crónica/diagnóstico , Enfermedad Granulomatosa Crónica/sangre , Leucocitos/citología , Separación Celular/instrumentación , Separación Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos
2.
Biosens Bioelectron ; 258: 116353, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-38696966

RESUMEN

Male infertility is a pervasive global reproductive challenge, primarily attributed to a decline in semen quality. Addressing this concern, there has been a growing focus on spermatozoa sorting in assisted reproductive technology. This study introduces a groundbreaking development in the form of a thermotaxis and rheotaxis microfluidic (TRMC) device designed for efficient motile spermatozoa sorting within a short 15-min timeframe. The TRMC device mimics the natural sperm sorting mechanism of the oviduct, selecting spermatozoa with superior motility and DNA integrity. The experimental outcomes demonstrate a remarkable enhancement in the percentage of progressive spermatozoa following sorting, soaring from 3.90% to an impressive 96.11% when subjected to a temperature decrease from 38 °C to 35 °C. Notably, sperm motility exhibited a substantial 69% improvement. The TRMC device exhibited a commendable recovery rate of 60.93%, surpassing current clinical requirements. Furthermore, the sorted spermatozoa displayed a notable reduction in the DNA fragmentation index to 6.94%, signifying a substantial 90% enhancement in DNA integrity. This remarkable advancement positions the TRMC device as highly suitable for applications in in vitro fertilization (IVF) and intracytoplasmic sperm injection (ICSI), offering a promising solution to male infertility challenges.


Asunto(s)
Dispositivos Laboratorio en un Chip , Motilidad Espermática , Espermatozoides , Masculino , Espermatozoides/fisiología , Espermatozoides/citología , Humanos , Diseño de Equipo , Infertilidad Masculina , Técnicas Biosensibles/instrumentación , Separación Celular/instrumentación , Fragmentación del ADN , Temperatura
3.
Methods Mol Biol ; 2804: 91-100, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38753142

RESUMEN

Circulating tumor cells (CTCs) isolated directly from whole blood opens new perspectives for cancer monitoring and the development of personalized treatments. However, due to their rarity among the multitude of blood cells, it remains a challenge to recover them alive with high level of purity, i.e., with few remaining white blood cells, and in a time frame compatible with the clinical context. Microfluidic chips have emerged as promising tools to address these challenges. We propose a two-step workflow including a pre-enrichment step, performed by a size-based pre-enrichment system, and a purification step, performed by an immunomagnetic chip. Here, we describe the protocol for the fabrication of the immunomagnetic microchip, the preparation of the sample, and the procedure for injection into the microchip allowing the sorting of the CTCs.


Asunto(s)
Separación Inmunomagnética , Dispositivos Laboratorio en un Chip , Células Neoplásicas Circulantes , Células Neoplásicas Circulantes/patología , Separación Inmunomagnética/métodos , Humanos , Separación Celular/métodos , Separación Celular/instrumentación , Neoplasias/patología , Neoplasias/sangre , Línea Celular Tumoral , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos
4.
Analyst ; 149(10): 2812-2825, 2024 May 13.
Artículo en Inglés | MEDLINE | ID: mdl-38644740

RESUMEN

Acute myeloid leukemia (AML) is the most common form of acute leukemia in adults and associated with poor prognosis. Unfortunately, most of the patients that achieve clinical complete remission after the treatment will ultimately relapse due to the persistence of minimal residual disease (MRD), that is not measurable using conventional technologies in the clinic. Microfluidics is a potential tool to improve the diagnosis by providing early detection of MRD. Herein, different designs of microfluidic devices were developed to promote lateral and vertical mixing of cells in microchannels to increase the contact area of the cells of interest with the inner surface of the device. Possible interactions between the cells and the surface were studied using fluid simulations. For the isolation of leukemic blasts, a positive selection strategy was used, targeting the cells of interest using a panel of specific biomarkers expressed in immature and aberrant blasts. Finally, once the optimisation was complete, the best conditions were used to process patient samples for downstream analysis and benchmarking, including phenotypic and genetic characterisation. The potential of these microfluidic devices to isolate and detect AML blasts may be exploited for the monitoring of AML patients at different stages of the disease.


Asunto(s)
Separación Celular , Leucemia Mieloide Aguda , Humanos , Leucemia Mieloide Aguda/patología , Leucemia Mieloide Aguda/sangre , Separación Celular/métodos , Separación Celular/instrumentación , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentación
5.
Lab Chip ; 24(9): 2575-2589, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38646820

RESUMEN

Leukocyte count is routinely performed for diagnostic purposes and is rapidly emerging as a significant biomarker for a wide array of diseases. Additionally, leukocytes have demonstrated considerable promise in novel cell-based immunotherapies. However, the direct retrieval of leukocytes from whole blood is a significant challenge due to their low abundance compared to erythrocytes. Here, we introduce a microfluidic-based platform that isolates and recovers leukocytes from diluted whole blood in a single step. Our platform utilizes a novel, sheathless method to initially sediment and focus blood cells into a dense stream while flowing through a tubing before entering the microfluidic device. A hexagonal-shaped structure, patterned at the device's inlet, directs all the blood cells against the channel's outer walls. The focused cells are then separated based on their size using the deterministic lateral displacement (DLD) microfluidic technique. We evaluated various parameters that could influence leukocyte separation, including different focusing structures (assessed both computationally and experimentally), the orientation of the tubing-chip interface, the effects of blood sample hematocrit (dilution), and flow rate. Our device demonstrated the ability to isolate leukocytes from diluted blood with a separation efficiency of 100%, a recovery rate of 76%, and a purity of 80%, while maintaining a cell viability of 98%. The device operates for over 30 min at a flow rate of 2 µL min-1. Furthermore, we developed a handheld pressure controller to drive fluid flow, enhancing the operability of our platform outside of central laboratories and enabling near-patient testing. Our platform can be integrated with downstream cell-based assays and analytical methods that require high leukocyte purity (80%), ranging from cell counting to diagnostics and cell culture applications.


Asunto(s)
Separación Celular , Leucocitos , Técnicas Analíticas Microfluídicas , Leucocitos/citología , Humanos , Técnicas Analíticas Microfluídicas/instrumentación , Separación Celular/instrumentación , Diseño de Equipo , Dispositivos Laboratorio en un Chip
6.
Anal Chem ; 96(17): 6764-6773, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38619911

RESUMEN

Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.


Asunto(s)
Separación Celular , Técnicas Analíticas Microfluídicas , Humanos , Separación Celular/instrumentación , Separación Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Porosidad , Dimetilpolisiloxanos/química , Dispositivos Laboratorio en un Chip , Polimetil Metacrilato/química
7.
Biomed Microdevices ; 26(2): 23, 2024 Apr 23.
Artículo en Inglés | MEDLINE | ID: mdl-38652182

RESUMEN

Millions of people are subject to infertility worldwide and one in every six people, regardless of gender, experiences infertility at some period in their life, according to the World Health Organization. Assisted reproductive technologies are defined as a set of procedures that can address the infertility issue among couples, culminating in the alleviation of the condition. However, the costly conventional procedures of assisted reproduction and the inherent vagaries of the processes involved represent a setback for its successful implementation. Microfluidics, an emerging tool for processing low-volume samples, have recently started to play a role in infertility diagnosis and treatment. Given its host of benefits, including manipulating cells at the microscale, repeatability, automation, and superior biocompatibility, microfluidics have been adopted for various procedures in assisted reproduction, ranging from sperm sorting and analysis to more advanced processes such as IVF-on-a-chip. In this review, we try to adopt a more holistic approach and cover different uses of microfluidics for a variety of applications, specifically aimed at sperm separation and analysis. We present various sperm separation microfluidic techniques, categorized as natural and non-natural methods. A few of the recent developments in on-chip fertilization are also discussed.


Asunto(s)
Separación Celular , Técnicas Reproductivas Asistidas , Espermatozoides , Humanos , Masculino , Espermatozoides/citología , Separación Celular/instrumentación , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Animales
8.
Arch Razi Inst ; 77(2): 647-660, 2022 04.
Artículo en Inglés | MEDLINE | ID: mdl-36284940

RESUMEN

Label-free inertial separation of the circulating tumor cells (CTCs) has attracted significant attention recently. The present study proposed a centrifugal platform for the inertial separation of the CTCs from the white blood cells. Particle trajectories of the contraction-expansion array (CEA) microchannels were analyzed by the finite element method. Four expansion geometries (i.e., circular, rectangular, trapezoidal, and triangular) were compared to explore their differences in separation possibilities. Different operational and geometrical parameters were investigated to achieve maximum separation efficiency. Results indicated that the trapezoidal CEA microchannel with ten expansions and a 100 µm channel depth had the best separation performance at an angular velocity of 100 rad/s. Reynolds number of 47 was set as the optimum value to apply minimum shear stress on the CTCs leading to 100% efficiency and 95% purity. Furthermore, the proposed system was simulated for whole blood by considering the red blood cells.


Asunto(s)
Células Neoplásicas Circulantes , Separación Celular/instrumentación , Separación Celular/métodos , Eritrocitos , Técnicas Analíticas Microfluídicas/métodos , Células Neoplásicas Circulantes/patología , Humanos
9.
São Paulo; s.n; s.n; 2022. 116 p. tab, graf.
Tesis en Inglés | LILACS | ID: biblio-1378343

RESUMEN

Stem cells are undifferentiated cells that can be distinguished from others by their ability to self-renew and to differentiate into new specific cell types. Mesenchymal stem cells (MSC) are adult stem cells that can be obtained from different sources, such as adipose tissue, bone marrow, dental pulp, and umbilical cord. They can either replicate, originating new identical cells, or differentiate into cells of mesodermal origin and from other germ layers. MSC have been studied as new tools for regenerative therapy. Although encouraging results have been demonstrated, MSC-based therapies still face a great barrier: the difficulty of isolating these cells from heterogeneous environments. MSC are currently characterized by immunolabelling through a set of multiple surface membrane markers, including CD29, CD73, CD90 and CD105, which are also expressed by other cell types. Hence, the present work aimed to identify new specific biomarkers for the characterization of human MSC using DNA aptamers produced by the SELEX (Systematic Evolution of Ligands by EXponential Enrichment) technique. Our results showed that MSC from different origins bound to DNA candidate aptamers, that is, DNA or RNA oligonucleotides selected from random libraries that bind specifically to biological targets. Aptamer-bound MSC could be isolated by fluorescenceactivated cell sorting (FACS) procedures, enhancing the induction of differentiation into specific phenotypes (chondrocytes, osteocytes and adipocytes) when compared to the whole MSC population. Flow cytometry analyses revealed that candidate aptamers bound to 50% of the MSC population from dental pulp and did not present significant binding rates to human fibroblasts or lymphocytes, both used as negative control. Moreover, immunofluorescence images and confocal analyses revealed staining of MSC by aptamers localized in the surfacemembrane of these cells. The results also showed internal staining of human monocytes by our investigated aptamers. A non-specific control aptamer (CNTR APT) obtained from the random pool was then utilized to compare the specificity of the aptamers bound to the analyzed non-apoptotic cells, showing no staining for MSC. However, 40% of the monocytes bound to the CNTR APT. Normalized data based on the cells bound to candidate aptamers compared to those bound to the CNTR APT, revealed a 10 to 16-fold higher binding rate for MSC against 2-fold for monocytes. Despite its low specificity, monocyte-aptamer binding occurs probably due to the expression of shared markers with MSC, since monocytes are derived from hematopoietic stem cells and are important for the immune system ability to internalize/phagocyte external molecules. Given that, we performed a pull-down assay followed by mass spectrometry analysis to detect which MSC-specific protein or other target epitope not coexpressed by monocytes or the CNTR APT would bind to the candidate aptamer. Distinguishing between MSC and monocyte epitopes is important, as both cells are involved in immunomodulatory effects after MSC transplantations. ADAM17 was found to be a target of the APT10, emerging as a possible biomarker of MSC, since its involvement in the inhibition of the TGF signaling cascade, which is responsible for the differentiation of MSC. Thus, MSC with a higher stemness profile should overexpress the protein ADAM17, which presents a catalytic site with affinity to APT10. Another target of Apt 10 is VAMP3, belonging to a transmembrane protein complex that is involved in endocytosis and exocytosis processes during immune and inflammatory responses. Overall, proteins identified as targets of APT10 may be cell surface MSC biomarkers, with importance for MSC-based cell and immune therapies


Células tronco são células indiferenciadas que podem ser distinguidas de outros tipos celulares por meio da habilidade de se auto renovarem e de se diferenciarem em novos tipos celulares. Células tronco mesenquimais (MSC) são células tronco adultas encontradas em diferentes tecidos como tecido adiposo, polpa de dente e cordão umbilical. Estas células podem se autodividir em células idênticas ou se diferenciarem em células de origem mesodermal. Estas células têm sido estudadas em novas aplicações que envolvem terapia regenerativas. Embora resultados encorajadores tenham sido demonstrados, terapias que utilizam MSC ainda encontram uma grande barreira: a dificuldade no isolamento destas células a partir de um ambiente heterogêneo. MSC são caracterizadas por populações positivas em ensaios de imunomarcação para os epítopos membranares CD29, CD73, CD90 e CD105, presentes também em outros tipos celulares. Assim, o presente trabalho tem o objetivo de identificar novos biomarcadores de MSC de origem humana, utilizando aptâmeros de DNA produzidos pela técnica SELEX (Systematic Evolution of Ligands by EXponential Enrichment) como ferramenta. Nossos resultados mostraram que MSC de diferentes origens ligam-se a aptâmeros (oligonucleotídeos de DNA ou RNA que atuam como ligantes específicos de alvos moleculares) de DNA candidatos que atuam no isolamento de MSC por meio da técnica FACS de separação celular, promovendo uma maior indução de diferenciação em células específicas (condrócitos, osteócitos e adipócitos) comparada com a população total de MSC. Análises de citometria de fluxo mostraram que os aptâmeros candidatos se ligam a 50% das MSC de polpa de dente e não apresentam taxa de ligação significante para fibroblastos e linfócitos de origem humana - utilizados como controles negativo. Além domais, imagens de imunofluorescência e confocal mostraram ligação na superfície da membrana de MSC e a marcação interna de monócitos a estes aptâmeros. Portanto, um aptâmero controle (CNTR APT) foi utilizado para comparar a especificidade dos aptâmeros ligados a células viáveis, mostrando a não ligação deste aptâmero a MSC. Porém, 40% da população de monócitos ligou-se ao CNTR APT. Uma normalização baseada na comparação entre as taxas de ligação entre células ligadas com aptâmeros candidatos e o aptâmero controle gerou uma taxa de especificidade entre 10-16 vezes maior para MSC contra 2,5 vezes para os monócitos. Deste modo, embora os resultados tenham mostrado uma taxa de ligação entre monócitos e aptâmeros, as MSC ligadas aos aptâmeros candidatos possuem uma maior taxa de especificidade devido a uma maior presença de antígenos que são expressos em ambas as células. Um ensaio de Pull Down seguido de espectrometria de massas foi utilizado para a identificação de biomarcadores que se ligariam aos aptâmeros candidatos, e que não seriam co-expressos por monócitos e por antígenos ligados ao aptâmero controle. Deste modo, a proteína ADAM17 foi identificada nas amostras de APT10 ligadas às MSC. Tal proteína está relacionada à inibição de uma cascata de sinalização da família de proteínas TGF, responsável pela diferenciação de MSC. Assim, MSC com maior potencial tronco deveriam expressar ADAM17 em maior quantidade. Tal proteína apresenta um sítio catalítico que demonstra interagir com o APT10, de acordo com predição Docking entre proteína e DNA. Foi identificada também, a proteína VAMP3, que pertence a um complexo proteico transmembranar responsável pelos processos de endocitose e exocitose, e que podem ter um papel importante na liberação de citocinas e outras moléculas relacionadas às respostas imune e inflamatórias. Deste modo, o APT10 identificou proteínas importantes que devem estar relacionas com a melhora de imunoterapias que utilizam MSC


Asunto(s)
Células Madre , Biomarcadores/análisis , Técnica SELEX de Producción de Aptámeros/instrumentación , Células Madre Mesenquimatosas/clasificación , Proteína ADAM17/farmacología , Aislamiento de Pacientes , Espectrometría de Masas/métodos , Coloración y Etiquetado/métodos , Trasplante/efectos adversos , Cordón Umbilical , ADN/agonistas , Factores de Crecimiento Transformadores/agonistas , Separación Celular/instrumentación , Citocinas/efectos adversos , Adipocitos/metabolismo , Condrocitos/clasificación , Scientists for Health and Research for Development , Células Madre Adultas/clasificación , Fibroblastos/química , Citometría de Flujo/instrumentación , Estratos Germinativos , Antígenos/efectos adversos
10.
Chem Commun (Camb) ; 57(100): 13655-13661, 2021 Dec 16.
Artículo en Inglés | MEDLINE | ID: mdl-34854439

RESUMEN

The study of the multimolecular crowding around cancer cells has opened up the possibility of developing new devices for cancer diagnosis and analysis through the measurement of intercellular communication related to cell proliferation and invasive metastasis associated with cancer malignancy. In particular, cells and extracellular vesicles that flow into the bloodstream contain metabolites and secreted products of the cancer microenvironment. These are positioned as targets for the development of new devices for the understanding and application of multimolecular crowding around cancer cells. Examples include the separation analysis of cancer cells in blood for the next generation of less invasive testing techniques, and mapping analysis using Raman scattering to detect cancer cells without staining. Another example is the evaluation of the relationship between exosomes and cancer traits for the exploration of new anti-cancer drugs, and the commercialization of exosome separation devices for ultra-early cancer diagnosis. The development of nanobiodevice engineering, which applies multimolecular crowding to conventional nanobioscience, is expected to contribute to the diagnosis and analysis of various diseases in the future.


Asunto(s)
Separación Celular/métodos , Neoplasias/diagnóstico , Separación Celular/instrumentación , Exosomas , Humanos , Neoplasias/sangre , Células Neoplásicas Circulantes , Espectrometría Raman
11.
ACS Appl Mater Interfaces ; 13(37): 43914-43924, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-34491739

RESUMEN

FluorAcryl 3298 (FA) is a UV-curable fluoroacrylate polymer commonly employed as a chemically resistant, hydrophobic, and oleophobic coating. Here, FA was used in a cleanroom-based microstructuring process to fabricate hydrophilic-in-hydrophobic (HiH) micropatterned surfaces containing femtoliter-sized well arrays. A short protocol involving direct UV photopatterning, an etching step, and final recovery of the hydrophobic properties of the polymer produced patterned substrates with micrometer resolution. Specifically, HiH microwell arrays were obtained with a well diameter of 10 µm and various well depths ranging from 300 nm to 1 µm with high reproducibility. The 300 nm deep microdroplet array (MDA) substrates were used for digital immunoassays, which presented a limit of detection in the attomolar range. This demonstrated the chemical functionality of the hydrophilic and hydrophobic surfaces. Furthermore, the 1 µm deep wells could efficiently capture particles such as bacteria, whereas the 300 nm deep substrates or other types of flat HiH molecular monolayers could not. Capturing a mixture of bacteria expressing red- and green-fluorescent proteins, respectively, served as a model for screening and selection of specific phenotypes using FA-MDAs. Here, green-fluorescent bacteria were specifically selected by overlaying a solution of gelatin methacryloyl (GelMA) mixed with a photoinitiator and using a high-magnification objective, together with custom pinholes, in a common fluorescence microscope to cross-link the hydrogel around the bacteria of interest. In conclusion, due to the straightforward processing, versatility, and low-price, FA is an advantageous alternative to more commonly used fluorinated materials, such as CYTOP or Teflon-AF, for the fabrication of HiH microwell arrays and other biphilic microstructures.


Asunto(s)
Resinas Acrílicas/química , Separación Celular/métodos , Hidrocarburos Fluorados/química , Inmunoensayo/métodos , Imagen Individual de Molécula/métodos , Anticuerpos/análisis , Anticuerpos/inmunología , Separación Celular/instrumentación , Escherichia coli , Interacciones Hidrofóbicas e Hidrofílicas , Proteínas Inmovilizadas/química , Proteínas Inmovilizadas/inmunología , Inmunoensayo/instrumentación , Imagen Individual de Molécula/instrumentación , Proteínas tau/química , Proteínas tau/inmunología
12.
Sci Rep ; 11(1): 18032, 2021 09 09.
Artículo en Inglés | MEDLINE | ID: mdl-34504124

RESUMEN

The isolation of a patient's metastatic cancer cells is the first, enabling step toward treatment of that patient using modern personalized medicine techniques. Whereas traditional standard-of-care approaches select treatments for cancer patients based on the histological classification of cancerous tissue at the time of diagnosis, personalized medicine techniques leverage molecular and functional analysis of a patient's own cancer cells to select treatments with the highest likelihood of being effective. Unfortunately, the pure populations of cancer cells required for these analyses can be difficult to acquire, given that metastatic cancer cells typically reside in fluid containing many different cell populations. Detection and analyses of cancer cells therefore require separation from these contaminating cells. Conventional cell sorting approaches such as Fluorescence Activated Cell Sorting or Magnetic Activated Cell Sorting rely on the presence of distinct surface markers on cells of interest which may not be known nor exist for cancer applications. In this work, we present a microfluidic platform capable of label-free enrichment of tumor cells from the ascites fluid of ovarian cancer patients. This approach sorts cells based on differences in biomechanical properties, and therefore does not require any labeling or other pre-sort interference with the cells. The method is also useful in the cases when specific surface markers do not exist for cells of interest. In model ovarian cancer cell lines, the method was used to separate invasive subtypes from less invasive subtypes with an enrichment of ~ sixfold. In ascites specimens from ovarian cancer patients, we found the enrichment protocol resulted in an improved purity of P53 mutant cells indicative of the presence of ovarian cancer cells. We believe that this technology could enable the application of personalized medicine based on analysis of liquid biopsy patient specimens, such as ascites from ovarian cancer patients, for quick evaluation of metastatic disease progression and determination of patient-specific treatment.


Asunto(s)
Ascitis/diagnóstico , Separación Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentación , Células Neoplásicas Circulantes/metabolismo , Neoplasias Ováricas/diagnóstico , Proteína p53 Supresora de Tumor/genética , Ascitis/genética , Ascitis/metabolismo , Ascitis/patología , Líquido Ascítico/metabolismo , Líquido Ascítico/patología , Biomarcadores de Tumor/genética , Biomarcadores de Tumor/metabolismo , Fenómenos Biomecánicos , Separación Celular/instrumentación , Femenino , Expresión Génica , Secuenciación de Nucleótidos de Alto Rendimiento , Humanos , Biopsia Líquida/métodos , Modelos Biológicos , Reacción en Cadena de la Polimerasa Multiplex , Mutación , Invasividad Neoplásica , Células Neoplásicas Circulantes/patología , Neoplasias Ováricas/genética , Neoplasias Ováricas/metabolismo , Neoplasias Ováricas/patología , Medicina de Precisión , Proteína p53 Supresora de Tumor/metabolismo
13.
ACS Appl Mater Interfaces ; 13(39): 46421-46430, 2021 Oct 06.
Artículo en Inglés | MEDLINE | ID: mdl-34546726

RESUMEN

Antibodies provide the functional biospecificity that has enabled the development of sensors, diagnostic tools, and assays in both laboratory and clinical settings. However, as multimarker screening becomes increasingly necessary due to the heterogeneity and complexity of human pathology, new methods must be developed that are capable of coordinating the precise assembly of multiple, distinct antibodies. To address this technological challenge, we engineered a bottom-up, high-throughput method in which DNA patterns, comprising unique 20-base pair oligonucleotides, are patterned onto a substrate using photolithography. These microfabricated surface patterns are programmed to hybridize with, and instruct the multiplexed assembly of, antibodies conjugated with the complementary DNA strands. We demonstrate that this simple, yet robust, approach preserves the antibody-binding functionality in two common applications: antibody-based cell capture and label-free surface marker screening. Using a simple proof-of-concept capture device, we achieved high purity separation of a breast cancer cell line, MCF-7, from a blood cell line, Jurkat, with capture purities of 77.4% and 96.6% when using antibodies specific for the respective cell types. We also show that antigen-antibody interactions slow cell trajectories in flow in the next-generation microfluidic node-pore sensing (NPS) device, enabling the differentiation of MCF-7 and Jurkat cells based on EpCAM surface-marker expression. Finally, we use a next-generation NPS device patterned with antibodies against E-cadherin, N-cadherin, and ß-integrin-three markers that are associated with epithelial-mesenchymal transitions-to perform label-free surface marker screening of MCF10A, MCF-7, and Hs 578T breast epithelial cells. Our high-throughput, highly versatile technique enables rapid development of customized, antibody-based assays across a host of diverse diseases and research thrusts.


Asunto(s)
Anticuerpos/inmunología , Separación Celular/métodos , ADN/química , Antígenos CD/inmunología , Antígenos CD/metabolismo , Biomarcadores/metabolismo , Cadherinas/inmunología , Cadherinas/metabolismo , Línea Celular Tumoral , Separación Celular/instrumentación , Transición Epitelial-Mesenquimal/fisiología , Humanos , Inmunoensayo/instrumentación , Inmunoensayo/métodos , Cadenas beta de Integrinas/inmunología , Cadenas beta de Integrinas/metabolismo , Dispositivos Laboratorio en un Chip , Técnicas Analíticas Microfluídicas/instrumentación , Técnicas Analíticas Microfluídicas/métodos , Oligodesoxirribonucleótidos/química , Prueba de Estudio Conceptual
14.
Int J Lab Hematol ; 43(6): 1635-1643, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34337874

RESUMEN

INTRODUCTION: The objective of the study was to evaluate the performance of the Abbott Alinity hq advanced multi angle polarized scatter separation (MAPSSTM )-based optical RBC technology, for the differentiation between iron deficiency anemia (IDA) and ß-thalassemia carrier status. METHODS: Four hundred and sixty-four samples were analyzed. 228 were healthy controls, 30 were ß-thalassemia carriers, and 40 were IDA. Receiver operating characteristics analysis evaluated the performance of red cell parameters and mathematical formulas. RESULTS: RBC concentration was the most efficient discriminant (area under the curve; AUC of 0.963, Youden Index of 0.88) followed by red blood cell distribution width in size distribution (AUC of 0.960 and YI of 0.86), and red blood cell distribution width coefficient of variation (AUC of 0.924, and YI of 0.74). The absolute reticulocyte concentration showed good diagnostic efficiency, with AUC of 0.808. Hemoglobin distribution width, the %CV of directly measured cellular hemoglobin concentration, and CHCr, the average hemoglobin concentration of reticulocytes have emerged as novel discriminating parameters, with AUC of 0.749 and 0.785, respectively. The England and Fraser index was the best discriminating mathematical formula based on Youden Index of 0.91. The Ricerca, red blood cell distribution width index, Green and King, and Mentzner Index formulas also showed strong discriminative power. The Shine and Lal index, together with the recent mathematical formula M/H, (ratio of percent microcytic and hypochromic red blood cells) demonstrated moderate performance with AUC of 0.796 and 0.740, respectively. CONCLUSION: Extended red cell analysis delivered by the advanced optical technology on the Alinity hq hematology analyzer has efficient diagnostic utility in the initial discrimination of the two most common microcytic anemias: IDA and ß-thalassemia trait.


Asunto(s)
Anemia Ferropénica/sangre , Anemia Ferropénica/diagnóstico , Separación Celular/métodos , Pruebas Diagnósticas de Rutina/métodos , Índices de Eritrocitos , Talasemia beta/sangre , Talasemia beta/diagnóstico , Anemia Ferropénica/etiología , Estudios de Casos y Controles , Separación Celular/instrumentación , Diagnóstico Diferencial , Pruebas Diagnósticas de Rutina/instrumentación , Pruebas Diagnósticas de Rutina/normas , Eritrocitos/citología , Eritrocitos/metabolismo , Humanos , Curva ROC , Talasemia beta/etiología
15.
Sci Rep ; 11(1): 16685, 2021 08 17.
Artículo en Inglés | MEDLINE | ID: mdl-34404819

RESUMEN

Microfluidics have been applied to filtration of rare tumor cells from the blood as liquid biopsies. Processing is highly limited by low flow rates and device clogging due to a single function of fluidic paths. A novel method using multifunctional hybrid functional microposts was developed. A swift by-passing route for non-tumor cells was integrated to prevent very common clogging problems. Performance was characterized using microbeads (10 µm) and human cancer cells that were spiked in human blood. Design-I showed a capture efficiency of 96% for microbeads and 87% for cancer cells at 1 ml/min flow rate. An improved Design-II presented a higher capture efficiency of 100% for microbeads and 96% for cancer cells. Our method of utilizing various microfluidic functions of separation, bypass and capture has successfully guaranteed highly efficient separation of rare cells from biological fluids.


Asunto(s)
Separación Celular/instrumentación , Técnicas Analíticas Microfluídicas/instrumentación , Recuento de Células , Línea Celular Tumoral , Diseño de Equipo , Humanos , Células Neoplásicas Circulantes/patología
16.
STAR Protoc ; 2(3): 100756, 2021 09 17.
Artículo en Inglés | MEDLINE | ID: mdl-34430922

RESUMEN

Primary T-cell culture is an invaluable model for investigating mechanisms underlying T-cell differentiation and function in health and disease. However, different culture conditions are required for immature versus mature CD4+ T cells. Here, we provide an improved culture protocol for immature naïve mouse CD4+ T cells, including details for splenocyte isolation, naïve CD4+ T-cell purification and differentiation, and functional evaluation via flow cytometry. This protocol can also be applied for immature human CD4+ T cells. For complete details on the execution of this protocol, please refer to Wang et al. (2019).


Asunto(s)
Linfocitos T CD4-Positivos/citología , Técnicas de Cultivo de Célula/métodos , Animales , Animales Recién Nacidos , Técnicas de Cultivo de Célula/instrumentación , Diferenciación Celular , Separación Celular/instrumentación , Separación Celular/métodos , Citocinas/genética , Citometría de Flujo , Expresión Génica , Ratones , Reacción en Cadena de la Polimerasa/métodos , Bazo/citología
17.
Mikrochim Acta ; 188(8): 242, 2021 07 06.
Artículo en Inglés | MEDLINE | ID: mdl-34226955

RESUMEN

In-depth study of cellular heterogeneity of rare cells (e.g. circulating tumour cells (CTCs) and circulating foetal cells (CFCs)) is greatly needed in disease management but has never been completely explored due to the current technological limitations. We have developed a retrieval method for single-cell detection using a static droplet array (SDA) device through liquid segmentation with almost no sample loss. We explored the potential of using SDA for low sample input and retrieving the cells of interest using everyday laboratory equipment for downstream molecular analysis. This single-cell isolation and retrieval method is low-cost, rapid and provides a solution to the remaining challenge for single rare cell detection. The entire process takes less than 15 min, is easy to fabricate and allows for on-chip analysis of cells in nanolitre droplets and retrieval of desired droplets. To validate the applicability of our device and method, we mimicked detection of single CTCs by isolating and retrieving single cells and perform real-time PCR on their mRNA contents.


Asunto(s)
Separación Celular/métodos , Microfluídica/métodos , Células Neoplásicas Circulantes/química , Técnicas Biosensibles , Separación Celular/instrumentación , Humanos , Dispositivos Laboratorio en un Chip , Células MCF-7 , Técnicas Analíticas Microfluídicas , Microfluídica/instrumentación , Reacción en Cadena de la Polimerasa , Análisis de la Célula Individual , Células THP-1
18.
Methods Mol Biol ; 2319: 143-152, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34331252

RESUMEN

Heart disease is one of the leading causes of death in the United States. Isolation and culture adult cardiomyocytes are important for studying cardiomyocyte contractility, heart hypertrophy, and cardiac failure. In contrast to neonatal cardiomyocyte isolation, adult mice cardiomyocytes isolation is challenging due to firm connections among cardiomyocytes through intercalated discs. The availability of newly generated genetically modified mouse lines requires to establish protocols to isolation and culture adult mouse cardiomyocyte for in vitro studies. In this manuscript, we described a straightforward method of isolating adult mouse cardiomyocytes using Langendorff perfusion apparatus. Briefly, the hearts were harvested from adult mice and the heart was mounted to Lagendorff apparatus. After perfusion with calcium depletion and collagenase digestion, the left ventricles were minced and filtered. Lastly, the separated cardiomyocytes were treated with CaCl2. The isolated cardiac myocytes can be utilized in a broad range of experiments including screening for drugs.


Asunto(s)
Técnicas de Cultivo de Célula/métodos , Separación Celular/instrumentación , Separación Celular/métodos , Preparación de Corazón Aislado/instrumentación , Preparación de Corazón Aislado/métodos , Miocitos Cardíacos/citología , Animales , Calcio/farmacología , Cloruro de Calcio/farmacología , Células Cultivadas , Colagenasas/química , Colagenasas/farmacología , Ratones , Miocitos Cardíacos/metabolismo , Perfusión/métodos
19.
Cells ; 10(5)2021 05 12.
Artículo en Inglés | MEDLINE | ID: mdl-34065800

RESUMEN

Reticulated platelets (RP) are the youngest platelet fraction released into the circulation. These immature platelets have increased RNA content, a larger cell volume, more dense granules, higher levels of surface activation markers and are thought to be more reactive compared to their mature counterparts. RP have been associated with cardiovascular disease, diabetes and increased mortality. Yet only a few animal studies investigating RP have been conducted so far and further investigations are warranted. Established methods to count RP are flow cytometry (staining with thiazole orange or SYTO13) or fully automated hematology analyzers (immature platelet fraction, IPF). IPF has been established as a diagnostic parameter in thrombocytopenia, cardiovascular disease and, in particular, the response to antiplatelet therapy. This review seeks to provide an overview of the key features of RP as well as preanalytical and analytical aspects that need to be considered when working with this platelet population.


Asunto(s)
Plaquetas/citología , Separación Celular/métodos , Reconocimiento de Normas Patrones Automatizadas/métodos , Animales , Benzotiazoles , Separación Celular/instrumentación , Modelos Animales de Enfermedad , Femenino , Citometría de Flujo/métodos , Humanos , Técnicas In Vitro , Ratones , Recuento de Plaquetas/métodos , Embarazo , Complicaciones del Embarazo , Pronóstico , Quinolinas , Factores de Riesgo , Coloración y Etiquetado , Trombocitopenia/diagnóstico
20.
ACS Appl Mater Interfaces ; 13(25): 30174-30186, 2021 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-34142547

RESUMEN

Analysis of circulating tumor cells (CTCs) is regarded as a useful diagnostic index to monitor tumor development and guide precision medicine. Although the immunoassay is a common strategy for CTC identification and heterogeneity characterization, it is challenged by poor reaction efficiency and laborious manipulations in microdevices, which hinder the sensitivity, throughput, simplification, and applicability. To meet the need for rapid, sensitive, and simple CTC analysis, we developed an efficient CTC detection system by integrating a 3D printed off-chip multisource reagent platform, a bubble retainer, and a single CTC capture microchip, which can achieve CTC capture and identification within 90 min. Compared with traditional CTC identification methods, this system decreases immunostaining time and antibody consumption by 90% and performs the on-chip immunoassay in a fully automated manner. Using this system, CTCs from the peripheral blood of 19 patients with various cancers were captured, detected, and compared with clinical data. The system shows great potential for early screening, real-time monitoring, and precision medicine for hepatocellular carcinoma (HCC). With the advantages of automation, stability, economy, and user-friendly operation, the proposed system is promising for clinical scenarios.


Asunto(s)
Carcinoma Hepatocelular/diagnóstico , Separación Celular/instrumentación , Neoplasias Hepáticas/diagnóstico , Técnicas Analíticas Microfluídicas/instrumentación , Células Neoplásicas Circulantes/patología , Detección Precoz del Cáncer/instrumentación , Diseño de Equipo , Células HCT116 , Humanos , Inmunoensayo/instrumentación , Pronóstico
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA