Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
1.
Mikrochim Acta ; 188(3): 73, 2021 02 06.
Artículo en Inglés | MEDLINE | ID: mdl-33550423

RESUMEN

Gelatin microsphere-coated Fe3O4@graphene quantum dots (Fe3O4@GQD@GM) were designed and synthesized as a novel sorbent via ultrasonic-assisted dispersive magnetic solid-phase extraction (UA-DMSPE) method. The synthesized sorbent was identified and confirmed by FT-IR, XRD, VSM, and SEM techniques. UA-DMSPE was combined with corona discharge ion mobility spectrometry for trace determination of desipramine, sertraline, and citalopram. Effective parameters were considered and optimized. The proposed method, under optimal conditions, showed excellent linearity in different concentration ranges (2-700 ng mL-1, R2 > 0.995), repeatability (RSD < 5.1%), good sensitivity (LODs in the range 0.6-1.5 ng mL-1), high preconcentration factor (PF = 207-218), and acceptable relative recoveries (93.5-101.8%). Eventually, this method was used to determine tricyclic antidepressants in various biological samples. Schematic presentation of the microextraction and monitoring of TCAs by ultrasonic-assisted dispersive magnetic solid phase microextraction-ion mobility spectrometry producer.


Asunto(s)
Antidepresivos Tricíclicos/aislamiento & purificación , Microesferas , Nanocompuestos/química , Puntos Cuánticos/química , Extracción en Fase Sólida/métodos , Adsorción , Antidepresivos Tricíclicos/sangre , Antidepresivos Tricíclicos/química , Antidepresivos Tricíclicos/orina , Citalopram/sangre , Citalopram/química , Citalopram/aislamiento & purificación , Citalopram/orina , Desipramina/sangre , Desipramina/química , Desipramina/aislamiento & purificación , Desipramina/orina , Gelatina/química , Grafito/química , Humanos , Límite de Detección , Fenómenos Magnéticos , Nanopartículas de Magnetita/química , Sertralina/sangre , Sertralina/química , Sertralina/aislamiento & purificación , Sertralina/orina
2.
J Sep Sci ; 44(6): 1195-1202, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33137222

RESUMEN

The synthesis and application of glutathione-coated magnetic nanocomposite were introduced with the purpose of developing a stable, cheap, operationally convenient, simple, fast, sensitive, and selective device for the microextraction of diazepam and sertraline for the first time. The prepared glutathione@Fe3 O4 nanocomposite was used as the sorbent in the form of magnetic solid-phase extraction. Afterward, the extracted analytes were desorbed by organic solvent and analyzed by high-performance liquid chromatography-ultraviolet detection. Several influential variables such as desorption time, desorption volume, sample pH, extraction time, and sorbent amount were screened through Plackett-Burman design and then optimized via Box-Behnken design. The obtained results showed that the above-mentioned method enjoys a good linear range (0.2-500 µg/L) with the coefficient of determination higher than 0.9927, low limits of determination (0.07-0.24 µg/L), acceptable limits of quantification (0.22-0.93 µg/L), good enrichment factors (128 and 153), and good spiking recoveries (95-105%) for diazepam and sertraline under the obtained optimized condition. Analyzing the real samples results in the confirmation of the presented method and it can be applied for the analysis of various organic compounds in biological samples.


Asunto(s)
Diazepam/aislamiento & purificación , Glutatión/química , Nanopartículas de Magnetita/química , Sertralina/aislamiento & purificación , Extracción en Fase Sólida , Adsorción , Cromatografía Líquida de Alta Presión , Diazepam/química , Diazepam/orina , Femenino , Voluntarios Sanos , Humanos , Fenómenos Magnéticos , Masculino , Tamaño de la Partícula , Sertralina/química , Sertralina/orina , Propiedades de Superficie
3.
Fertil Steril ; 114(6): 1278-1287, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33066974

RESUMEN

OBJECTIVE: To prospectively investigate the association of selective serotonin reuptake inhibitor (SSRI) exposure through critical windows of pregnancy establishment with fecundability and pregnancy loss. DESIGN: Prospective cohort study using longitudinal urine measurements of common SSRIs while women are actively trying to conceive. SETTING: Four clinical sites. PATIENT(S): A total of 1,228 women without uncontrolled depression/anxiety, attempting natural conception while participating in a randomized trial of preconception-initiated low-dose aspirin. INTERVENTIONS(S): Not applicable. MAIN OUTCOME MEASURE(S): Urinary SSRIs (fluoxetine, sertraline, escitalopram/citalopram) were measured while trying to conceive and, for women who became pregnant, at weeks 0, 4, and 8 of pregnancy. Fecundability odds ratios and incidence of pregnancy loss and live birth were estimated. RESULT(S): A total of 172 women (14%) were exposed to SSRIs while trying to conceive. SSRI exposure was associated with 24% reduced fecundability, and accordingly, a nonsignificant 9% lower live birth incidence, with significantly lower live birth in fluoxetine-exposed women. SSRI exposure was not associated with subsequent pregnancy loss, whether exposure was before conception or at 0, 4, or 8 weeks of gestation, although estimates varied by specific SSRI drug. CONCLUSION(S): Women using SSRIs may have more difficulty becoming pregnant, and although SSRI exposure overall was not associated with pregnancy loss, fluoxetine deserves caution and future study. CLINICAL TRIAL REGISTRATION NUMBER: NCT00467363.


Asunto(s)
Aborto Espontáneo/inducido químicamente , Fertilidad/efectos de los fármacos , Inhibidores Selectivos de la Recaptación de Serotonina/efectos adversos , Inhibidores Selectivos de la Recaptación de Serotonina/orina , Aborto Espontáneo/diagnóstico , Aborto Espontáneo/orina , Adulto , Citalopram/orina , Femenino , Fluoxetina/efectos adversos , Fluoxetina/orina , Humanos , Nacimiento Vivo , Embarazo , Primer Trimestre del Embarazo/orina , Estudios Prospectivos , Ensayos Clínicos Controlados Aleatorios como Asunto , Medición de Riesgo , Factores de Riesgo , Sertralina/efectos adversos , Sertralina/orina , Factores de Tiempo , Estados Unidos , Adulto Joven
4.
Artículo en Inglés | MEDLINE | ID: mdl-32213465

RESUMEN

In this study, the use of switchable hydrophilicity solvent with a simple and low-cost lab-made device for the extraction procedure in homogeneous liquid-liquid microextraction is proposed for the first time in the determination of antidepressants in human urine. The antidepressants studied consisted of fluoxetine, amitriptyline, nortriptyline, imipramine, desipramine and sertraline. The optimization of the main parameters that can influence on the extraction efficiency was performed through multivariate approaches. The analytes were separated and identified by gas chromatography coupled to mass spectrometry (GC-MS). The optimal extraction conditions consisted of using N,N-dimethylcyclohexylamine (DMCHA) as the switchable hydrophilicity solvent (SHS), 500 µL of urine sample previously diluted with ultrapure water at 1:1 ratio (v/v), 200 µL of a mixture of SHS:HCl 6 mol L-1 (1:1 v/v), 600 µL of NaOH 10 mol L-1 and 3 min of extraction time. A volume of 40 µL of diphenylamine at concentration of 500 µg L-1 (20 ng) was used as internal standard. The method developed was in-house validated, providing coefficients of determination higher than 0.995 for all analytes, limits of detection (LOD) from 0.02 to 0.88 µg L-1, limits of quantification (LOQ) from 0.05 to 2.92 µg L-1, relative recoveries of 68 to 102%, intra-day precision from 0.5 to 15.9%, inter-day precision from 4.2 to 19.3%, selectivity and robustness. The method proposed was successfully applied in five human urine samples from a Toxicological Information Center located in Porto Alegre (Brazil). The results demonstrated that the µP-SHS-HLLME approach is highly cost-effective, rapid, simple and environmentally-friendly with satisfactory analytical performance.


Asunto(s)
Antidepresivos/orina , Adulto , Amitriptilina/orina , Ciclohexilaminas/química , Desipramina/orina , Fluoxetina/orina , Cromatografía de Gases y Espectrometría de Masas , Tecnología Química Verde , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Imipramina/orina , Límite de Detección , Microextracción en Fase Líquida , Nortriptilina/orina , Sertralina/orina , Solventes/química
5.
Bioanalysis ; 12(1): 35-52, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-31849264

RESUMEN

Aim: Routine therapeutic drug monitoring is highly recommended since common antidepressant combinations increase the risk of drug-drug interactions or overlapping toxicity. Materials & methods: A magnetic solid-phase extraction by using C18-functionalized magnetic silica nanoparticles (C18-Fe3O4@SiO2 NPs) as sorbent was proposed for rapid extraction of venlafaxine, paroxetine, fluoxetine, norfluoxetine and sertraline from clinical plasma and urine samples followed by ultra-HPLC-MS/MS assay. Results: The synthesized C18-Fe3O4@SiO2 NPs showed high magnetization and efficient extraction for the analytes. After cleanup by magnetic solid-phase extraction, no matrix effects were found in plasma and urine matrices. The analytes showed LODs among 0.15-0.75 ng ml-1, appropriate linearity (R ≥ 0.9990) from 2.5 to 1000 ng ml-1, acceptable accuracies 89.1-110.9% with precisions ≤11.0%. The protocol was successfully applied for the analysis of patients' plasma and urine samples. Conclusion: It shows high potential in routine therapeutic drug monitoring of clinical biological samples.


Asunto(s)
Antidepresivos/análisis , Nanopartículas de Magnetita/química , Antidepresivos/aislamiento & purificación , Antidepresivos/metabolismo , Cromatografía Líquida de Alta Presión , Fluoxetina/análogos & derivados , Fluoxetina/sangre , Fluoxetina/aislamiento & purificación , Fluoxetina/orina , Humanos , Concentración de Iones de Hidrógeno , Límite de Detección , Paroxetina/sangre , Paroxetina/aislamiento & purificación , Paroxetina/orina , Reproducibilidad de los Resultados , Sertralina/sangre , Sertralina/aislamiento & purificación , Sertralina/orina , Dióxido de Silicio/química , Extracción en Fase Sólida , Solventes/química , Espectrometría de Masas en Tándem , Clorhidrato de Venlafaxina/sangre , Clorhidrato de Venlafaxina/aislamiento & purificación , Clorhidrato de Venlafaxina/orina
6.
Clin Chim Acta ; 499: 81-86, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31491368

RESUMEN

BACKGROUND: Many clinical toxicology laboratories receive urine specimens in urine cups that contain point of care (POC) drug testing strips. We conducted this study to evaluate the effect on the stability of commonly measured drugs in the clinical toxicology laboratory when urine is exposed to POC urine drug testing cups. METHODS: Drug free urine was spiked with 85 drugs that were measured by a validated liquid chromatography mass spectrometry (LCMS) method after exposure to POC urine drug testing cups at ambient and 2-6 °C temperatures. Alterations ≥20% were defined as significant changes in the drugs concentration. RESULTS: Concentrations of amitriptyline, cyclobenzaprine, fentanyl, fluoxetine, flunitrazepam, nortriptyline, paroxetine, and sertraline were significantly reduced when urine specimens were stored inside POC urine drug testing cups for 24 h at ambient temperature. Storage of urine in urine chemistry dipsticks reduced the concentration of several drugs. When spiked urine was exposed to an increasing number of POC urine drug testing strips, the concentrations of some drugs were reduced in a dose-dependent manner. The drugs that were absorbed by POC urine drug testing strips were partially back extracted from the strips. CONCLUSION: Exposure of urine specimens to POC urine drug testing strips reduces the concentration of several drugs measured by LCMS method.


Asunto(s)
Pruebas en el Punto de Atención , Amitriptilina/análogos & derivados , Amitriptilina/orina , Cromatografía Liquida , Almacenaje de Medicamentos , Fentanilo/orina , Flunitrazepam/orina , Fluoxetina/orina , Humanos , Espectrometría de Masas , Nortriptilina/orina , Paroxetina/orina , Sertralina/orina
8.
Talanta ; 101: 460-4, 2012 Nov 15.
Artículo en Inglés | MEDLINE | ID: mdl-23158349

RESUMEN

A novel method for the determination of sertraline using dispersive liquid-liquid microextraction (DLLME) coupled with capillary electrophoresis (CE) was developed. Acetone and dichloromethane were used as the disperser solvent and extraction solvent, respectively. A mixture of the extraction and disperser solvents was rapidly injected into a 1.0 mL aqueous sample to form a cloudy solution. After the extraction, sertraline was analyzed using CE that was equipped with UV detection. A 74-fold improvement in the sensitivity was observed when DLLME was used to extract sertraline. Since the DLLME extract residue was redissolved with 5 µL of water that contained 20% methanol, the detection sensitivity was further enhanced through the use of field-amplified sample stacking (FASS). A 11-fold improvement in the sensitivity was obtained when FASS was used to on-line concentrate sertraline. Under optimal extraction and stacking conditions, the calibration curve, which ranged from 0.01 to 1 µM was observed to be linear. The limit of detection (LOD) at a signal-to-noise ratio of 3 was 2.5 nM for sertraline. An approximately 814-fold improvement in the sensitivity was observed for sertraline compare with injection of standard solution without the DLLME and FASS procedures. This developed method was successfully applied to the determination of sertraline in human urine samples.


Asunto(s)
Electroforesis Capilar/métodos , Inhibidores Selectivos de la Recaptación de Serotonina/análisis , Sertralina/análisis , Humanos , Límite de Detección , Microextracción en Fase Líquida , Inhibidores Selectivos de la Recaptación de Serotonina/orina , Sertralina/orina
10.
Anal Bioanal Chem ; 382(6): 1351-9, 2005 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-15986209

RESUMEN

In this paper a solid-phase microextraction-gas chromatography-mass spectrometry (SPME-GC-MS) method is proposed for a rapid analysis of some frequently prescribed selective serotonin re-uptake inhibitors (SSRI)-venlafaxine, fluvoxamine, mirtazapine, fluoxetine, citalopram, and sertraline-in urine samples. The SPME-based method enables simultaneous determination of the target SSRI after simple in-situ derivatization of some of the target compounds. Calibration curves in water and in urine were validated and statistically compared. This revealed the absence of matrix effect and, in consequence, the possibility of quantifying SSRI in urine samples by external water calibration. Intra-day and inter-day precision was satisfactory for all the target compounds (relative standard deviation, RSD, <14%) and the detection limits achieved were <0.4 ng mL(-1) urine. The time required for the SPME step and for GC analysis (30 min each) enables high throughput. The method was applied to real urine samples from different patients being treated with some of these pharmaceuticals. Some SSRI metabolites were also detected and tentatively identified.


Asunto(s)
Antidepresivos de Segunda Generación/orina , Cromatografía de Gases y Espectrometría de Masas/métodos , Inhibidores Selectivos de la Recaptación de Serotonina/orina , Microextracción en Fase Sólida/métodos , Citalopram/orina , Ciclohexanoles/orina , Fluoxetina/orina , Fluvoxamina/orina , Humanos , Mianserina/análogos & derivados , Mianserina/orina , Mirtazapina , Reproducibilidad de los Resultados , Sertralina/orina , Clorhidrato de Venlafaxina
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...