Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.785
Filtrar
1.
J Refract Surg ; 40(6): e407-e419, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848051

RESUMEN

PURPOSE: To assess clinical outcomes after cataract surgery with bilateral implantation of a new bi-aspheric diffractive intraocular lens (IOL). METHODS: Thirty patients underwent bilateral implantation of the Asqelio Trifocal Toric IOL (AST Products, Inc) and were evaluated 3 months postoperatively. Main outcomes included refractive error, photopic monocular and binocular uncorrected and corrected distance (UDVA, CDVA), intermediate (UIVA, CDIVA) at 60 cm, and near (UNVA, CDNVA) at 40 cm visual acuities. Mesopic monocular and binocular CDNVA were also measured. Defocus curves, binocular contrast sensitivity under photopic and mesopic conditions with and without glare and rotational stability were determined. Patients completed Catquest-9SF and visual symptoms questionnaires. RESULTS: Average values of binocular photopic CDVA, CDIVA, and CDNVA, and mesopic CDNVA were -0.04 ± 0.06, 0.02 ± 0.08, 0.02 ± 0.07, and 0.22 ± 0.11 logMAR, respectively. All patients achieved cumulative CDVA ⩾ 20/25, and CDIVA and CDNVA of 20/32 or better. Binocular depth of focus was approximately 3.25 diopters (D). Mean postoperative spherical equivalent was -0.08 ± 0.26 D, with 95% of eyes within ±0.50 D. Mean postoperative refractive cylinder was -0.22 ± 0.27 D, with 91.67% of eyes within 0.50 D or less, respectively. IOL rotation averaged 0.25 ± 0.65 degrees, all eyes having rotation of less than 5 degrees. Contrast sensitivity was within or above normal levels under photopic and mesopic conditions, with or without glare, except for 12 cpd under mesopic conditions with glare. Questionnaire responses indicated 96.67% of patients were satisfied or very satisfied with postoperative vision, and 80.00% to 96.67% reported no difficulty in different daily activities. CONCLUSIONS: The Asqelio Trifocal Toric IOL demonstrated favorable outcomes, providing excellent visual performance at all distances, precise refractive results, and remarkable rotational stability. Patients reported high satisfaction levels and minimal difficulty in daily activities. [J Refract Surg. 2024;40(6):e407-e419.].


Asunto(s)
Sensibilidad de Contraste , Implantación de Lentes Intraoculares , Lentes Intraoculares Multifocales , Satisfacción del Paciente , Facoemulsificación , Diseño de Prótesis , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Visión Binocular/fisiología , Masculino , Femenino , Anciano , Refracción Ocular/fisiología , Seudofaquia/fisiopatología , Persona de Mediana Edad , Sensibilidad de Contraste/fisiología , Encuestas y Cuestionarios , Estudios Prospectivos , Anciano de 80 o más Años , Lentes Intraoculares , Resultado del Tratamiento
2.
J Refract Surg ; 40(6): e398-e406, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38848057

RESUMEN

PURPOSE: To assess the visual and refractive outcomes of patients implanted with a toric extended depth-of-focus (EDOF) intraocular lens (IOL) following cataract surgery. METHODS: A total of 44 eyes implanted with the EDOF LuxSmart toric IOL were evaluated 4 to 6 months postoperatively. The main outcomes measurements evaluated were refractive error, rotational stability, distance, intermediate, and near visual acuities, defocus curve, photopic and mesopic contrast sensitivity, wavefront aberrations, and modulation transfer function, and the Catquest-9SF-questionnaire. RESULTS: The mean postoperative spherical equivalent and cylinder were -0.02 ± 0.26 and -0.17 ± 0.29 diopters (D), respectively. A total of 90.45% and 100% of the eyes had a postoperative spherical equivalent within ±0.50 and ±1.00 D, respectively (this being 93.18% and 100% for the refractive cylinder). The mean rotational stability was 0.61 ± 1.61 degrees. The mean binocular corrected distance visual acuity (CDVA), corrected distance intermediate visual acuity (CDIVA), and corrected distance near visual acuity (CDNVA) were -0.02 ± 0.06, 0.07 ± 0.08, and 0.26 ± 0.09 logMAR, respectively. The CDVA was 20/25 or better in 95.45% of patients, CDIVA was 20/25 or better in 72.73%, and CDNVA was 20/40 or better in 72.73%. The defocus curve showed good visual acuity at distance and intermediate vergences. The contrast sensitivity and optical quality outcomes were good with mean higher order, spherical, and coma aberration values of 0.161 ± 0.155, -0.019 ± 0.048, and 0.080 ± 0.065 µm, respectively. A total of 90.9% of patients were either fairly satisfied or very satisfied with their vision after the surgery, and 77.7% of patients reported no difficulties when reading text in newspapers. CONCLUSIONS: Implantation of the toric pure refractive EDOF technology IOL provides good refractive, optical, and visual quality at different distances, with high levels of patient satisfaction being reported. [J Refract Surg. 2024;40(6):e398-e406.].


Asunto(s)
Sensibilidad de Contraste , Aberración de Frente de Onda Corneal , Percepción de Profundidad , Implantación de Lentes Intraoculares , Lentes Intraoculares , Facoemulsificación , Diseño de Prótesis , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Sensibilidad de Contraste/fisiología , Seudofaquia/fisiopatología , Refracción Ocular/fisiología , Aberración de Frente de Onda Corneal/fisiopatología , Percepción de Profundidad/fisiología , Visión Binocular/fisiología , Encuestas y Cuestionarios , Estudios Prospectivos , Satisfacción del Paciente , Anciano de 80 o más Años , Resultado del Tratamiento
3.
Eye (Lond) ; 38(Suppl 1): 9-14, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38580741

RESUMEN

BACKGROUND/OBJECTIVE: To evaluate the visual performance of a purely refractive extended depth of focus (EDF) intraocular lens (IOL). SUBJECTS/METHODS: A prospective, multi-center, randomized, subject/evaluator-masked study. Subjects were bilaterally implanted with the EDF test (Model ZEN00V, N = 60) or an enhanced monofocal control (Model ICB00, N = 57) IOL. Monocular corrected distance (CDVA), intermediate (DCIVA), near acuities (DCNVA) and patient reported visual symptoms were evaluated at the 6-month visit. Monocular mesopic contrast sensitivity (CS) and depth of focus (DOF) testing were assessed at 3 months. RESULTS: CDVA (Mean ± SD) was -0.06 ± 0.08 for test and -0.05 ± 0.08 logMAR for control groups. DCIVA was 0.13 ± 0.08 for test and 0.18 ± 0.14 logMAR for control groups (p = 0.0127). DCNVA was 0.37 ± 0.10 for test and 0.43 ± 0.16 logMAR for control groups (p = 0.0137). Test lens was statistically superior for intermediate and near. Overall, 91.7% (halos), 95.0% (starbursts) and 95.0% (glare) of test lens patients reported that they did not experience, were not bothered, or were slightly bothered by specific visual symptoms, compared to 98.2%, 100% and 96.5% in the control group. The DOF range over which monocular visual acuity was 0.20 logMAR or better was -1.6 D for the test lens. Mesopic CS was comparable between both groups, falling within 0.11 log units for all measured cycles per degree with and without glare. CONCLUSION: The EDF IOL demonstrated extended range of vision and statistically superior intermediate and near performance compared to the monofocal IOL. Distance visual acuity, contrast sensitivity and dysphotopsia profile were similar to the monofocal IOL.


Asunto(s)
Sensibilidad de Contraste , Percepción de Profundidad , Implantación de Lentes Intraoculares , Lentes Intraoculares , Seudofaquia , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Sensibilidad de Contraste/fisiología , Anciano , Persona de Mediana Edad , Percepción de Profundidad/fisiología , Seudofaquia/fisiopatología , Diseño de Prótesis , Refracción Ocular/fisiología , Facoemulsificación , Método Doble Ciego , Satisfacción del Paciente
4.
J Cataract Refract Surg ; 50(5): 505-510, 2024 May 01.
Artículo en Inglés | MEDLINE | ID: mdl-38651698

RESUMEN

PURPOSE: To compare flange depth for a modified scleral pocket (SP) vs no scleral pocket (NSP) technique (Yamane technique) for intrascleral intraocular lens (IOL) fixation. SETTING: Instituto de Oftalmología Santa Fe, Santa Fe, Argentina. DESIGN: Prospective, randomized, single-surgeon, observational study. METHODS: Eyes with aphakia and no capsular support were included. They were divided into 2 groups: one was programmed for a double-needle flanged intrascleral IOL fixation as originally described by Shin Yamane with NSP and the second group had a modified SP technique. Flange depth was measured with anterior-segment optical coherence tomography (AS-OCT) at 1 month, 3 months, 6 months, and 12 months postoperatively, and the results were compared. RESULTS: Each group comprised 18 eyes of 18 patients, giving a total of 36 flanges per group. The groups were comparable preoperatively. At 12 months, uncorrected distance visual acuity and corrected distance visual acuity (CDVA) were not statistically different for both groups (P = .333; P = .448). Spherical equivalent (SEQ) was not significantly different between groups at 12 months postoperatively (P = .078). AS-OCT revealed a significantly deeper flange position for the SP group at 1 month, 3 months, 6 months, and 12 months postoperatively (P < .05). CONCLUSIONS: When performing a double-needle intrascleral IOL fixation in aphakic eyes with no capsular support, a modified scleral pocket technique provides a significantly deeper flange position with no difference in CDVA or SEQ 12 months postoperatively.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Esclerótica , Tomografía de Coherencia Óptica , Agudeza Visual , Humanos , Esclerótica/cirugía , Implantación de Lentes Intraoculares/métodos , Estudios Prospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Persona de Mediana Edad , Anciano , Afaquia Poscatarata/cirugía , Afaquia Poscatarata/fisiopatología , Colgajos Quirúrgicos , Técnicas de Sutura , Seudofaquia/fisiopatología , Refracción Ocular/fisiología
5.
BMC Ophthalmol ; 24(1): 189, 2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38658894

RESUMEN

PURPOSE: To evaluate short-term visual and refractive outcomes after implantation of a diffractive trifocal intraocular lens (IOL) in cataract patients with phacoemulsification (PHACO) and femtosecond laser assisted cataract surgery (FLACS). SETTING: Department of Ophthalmology, Shanghai Aier Eye Hospital, China. DESIGN: A retrospective, observational study. METHODS: Patients who underwent cataract surgery combined with Acrysoft IQ PanOptix trifocal IOL implantation were enrolled and divided into three groups: PHACO group, LAstig-FLACS group (astigmatism less then 1D) and HAstig-FLACS group (astigmatism more than 1D). Logarithm of the minimum angle of resolution (logMAR) visual acuity of uncorrected distance (UDVA), intermediate (UIVA), near visual (UNVA), defocus curve, surgically induced astigmatism (SIA) were evaluated in 1 months postoperatively and wavefront aberrations were evaluated in 6 months. RESULTS: 101 eyes of 60 patients were included with 31 eyes in PHACO group, 45 eyes in LAstig-FLACS group and 25 eyes in HAstig-FLACS group. Significant difference was found of internal Strehl Ratio (SR) between PHACO and LAstig-FLACS group (P = 0.026). In PHACO group, 79.31%, 86.21%, 72.41% of eyes gain visual acuity LogMAR 0.1 or more in UDVA, UIVA and UNVA, while 83.72%, 93.02%, 93.02% of those in LAstig-FLACS group and 92.00%, 84.00%, 76.00% in HAstig-FLACS group. CONCLUSIONS: Panoptix diffractive trifocal IOL provides satisfied visual outcome in no matter FLACS or PHACO. Besides, trifocal IOL implantation via FLACS can provide a better accumulative visual acuity outcome at all distance than PHACO in 1 month. Femtosecond laser assisted limbal relaxing incisions (FLLRIs) is an excellent way to reduce a patient's corneal astigmatism.


Asunto(s)
Terapia por Láser , Lentes Intraoculares Multifocales , Facoemulsificación , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Masculino , Femenino , Facoemulsificación/métodos , Agudeza Visual/fisiología , Persona de Mediana Edad , Terapia por Láser/métodos , Anciano , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares/métodos , Seudofaquia/fisiopatología , Resultado del Tratamiento , Diseño de Prótesis , Extracción de Catarata/métodos , Estudios de Seguimiento
6.
Eye (Lond) ; 38(Suppl 1): 15-20, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38580742

RESUMEN

PURPOSE: To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS: Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS: In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS: The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Diseño de Prótesis , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Estudios Prospectivos , Femenino , Masculino , Persona de Mediana Edad , Anciano , Percepción de Profundidad/fisiología , Seudofaquia/fisiopatología , Errores de Refracción/fisiopatología , Facoemulsificación , Satisfacción del Paciente , Simulación por Computador , Refracción Ocular/fisiología , Astigmatismo/fisiopatología , Visión Binocular/fisiología
7.
BMC Ophthalmol ; 24(1): 198, 2024 Apr 26.
Artículo en Inglés | MEDLINE | ID: mdl-38671381

RESUMEN

BACKGROUND: Postoperative performance, including best corrected distance visual acuity (BCDVA) and optical metrics (from the OQAS and iTrace devices), was compared among 4 different intraocular lenses (IOLs). METHODS: This prospective observational study included 104 eyes from 104 subjects who underwent cataract surgery combined with implantation of 4 different IOLs: monofocal (Mon) IOLs, segmental refractive (SegRef) IOLs, diffractive (Dif) IOLs and extended depth of focus (EDoF) IOLs. Postoperative BCDVA and optical metrics were collected at the 6th month. The OQAS optical metrics included the objective scattering index (OSI), Strehl ratio (SR), modulation transfer function (MTF) cut-off frequency, and predicted visual acuity (PVA); the iTrace optical metrics included blur/double vision, glare/halo, starburst, mixed focus, night myopia, and night hyperopia. RESULTS: There was no significant difference in BCDVA among the 4 groups (P = 0.059; power = 70.3%). Differences were observed in all OQAS optical metrics among the groups (all P < 0.001). Overall, Mon IOLs and EDoF IOLs exhibited better performance than Dif IOLs and SegRef IOLs. Starburst was the only iTrace optical metric that differed among the groups (P < 0.001): SegRef IOLs caused more starbursts than Mon IOLs (P = 0.001), Dif IOLs (P = 0.006) and EDoF IOLs (P < 0.001). Spearman rank correlation analysis was used to determine the relationships among the iTrace optical metrics, OQAS optical metrics and BCDVA: starburst was negatively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001); mixed focus was positively correlated with BCDVA, PVA at contrasts of 100% and 20%, OSI, and MTF cut-off frequency (all P ≤ 0.001). CONCLUSIONS: Postoperative BCDVA and optical metrics varied among the different IOLs, which should be taken into account in the selection and management of IOLs for cataract patients. TRIAL REGISTRATION: This study was approved by the First Affiliated Hospital of Guangzhou Medical University Ethical Review Board (No. 50 2022).


Asunto(s)
Lentes Intraoculares , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Femenino , Masculino , Anciano , Persona de Mediana Edad , Facoemulsificación , Refracción Ocular/fisiología , Implantación de Lentes Intraoculares , Diseño de Prótesis , Periodo Posoperatorio , Seudofaquia/fisiopatología , Óptica y Fotónica
8.
BMC Ophthalmol ; 24(1): 183, 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38649861

RESUMEN

AIM: To evaluate the objective visual outcomes following implantation of extended depth of focus intraocular lens (EDOF IOL) in individuals with varying axial lengths (AL) and targeted refraction. METHODS: This retrospective study comprised age-matched eyes that underwent implantation of the EDOF IOL. Eyes were categorized based on AL into groups: control group with AL < 26 mm; high myopia group with AL ≥ 26 mm. Each group was then subdivided based on postoperative spherical equivalent (SE). Follow-up at three months included assessment of uncorrected visual acuity at different distances, contrast sensitivity (CS), refractive outcomes, and spectacle independence. RESULTS: Overall, this study included 100 eyes from 100 patients, comprising 50 males (50.00%) and 50 females (50.00%), with 20 eyes in each group. In the control group, the uncorrected distance visual acuity (UDVA) at 5 and 3 m (m) in the - 1.50 to -0.75 group was inferior to that of the - 0.75 to 0.00 group (P = 0.004). Conversely, the uncorrected near visual acuity (UNVA) at 33 cm in the - 1.50 to -0.75 group was superior to that of the - 0.75 to 0.00 group (P = 0.005). Within the high myopia group, the UDVA at 5 and 3 m in the - 2.25 to -1.50 group was worse than in the - 0.75 to 0.00 group (P = 0.009 and 0.008, respectively). However, the UNVA at 33 cm in the - 2.25 to -1.50 group was better than in the - 0.75 to 0.00 group (P = 0.020). No significant differences were observed among the groups for corrected distance visual acuity (CDVA) (P > 0.05). Additionally, in the high myopia group, the CS of the - 2.25 to -1.50 group was lower compared to that of the - 0.75 to 0.00 group (P = 0.017). Among high myopia patients, 90.00% with refraction ranging from - 1.50 to -0.75 reported achieving overall spectacle independence. CONCLUSIONS: Implantation of extended depth of focus intraocular lenses (IOLs) yields satisfactory visual and refractive outcomes in eyes with axial myopia. Among high myopia patients, a refraction ranging from - 1.50 to -0.75 diopters achieves superior visual quality compared to other postoperative myopic diopters.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Miopía , Refracción Ocular , Agudeza Visual , Humanos , Femenino , Masculino , Estudios Retrospectivos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Persona de Mediana Edad , Miopía/fisiopatología , Miopía/cirugía , Anciano , Diseño de Prótesis , Adulto , Sensibilidad de Contraste/fisiología , Facoemulsificación , Seudofaquia/fisiopatología , Longitud Axial del Ojo , Percepción de Profundidad/fisiología , Estudios de Seguimiento
9.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38466765

RESUMEN

PURPOSE: To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT). METHODS: Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle. RESULTS: During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all). CONCLUSIONS: The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3):e164-e172.].


Asunto(s)
Cristalino , Miopía , Lentes Intraoculares Fáquicas , Humanos , Implantación de Lentes Intraoculares/métodos , Miopía/cirugía , Acomodación Ocular , Cámara Anterior/diagnóstico por imagen , Seudofaquia/cirugía , Tomografía de Coherencia Óptica , Biometría
10.
J Fr Ophtalmol ; 47(4): 104105, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38428321

RESUMEN

PURPOSE: To compare the visual outcomes in both eyes of patients who undergo phacoemulsification and trifocal intraocular lens (IOL) implantation and have asteroid hyalosis (AH) or synchysis scintillans (SS) in only one eye. METHODS: A retrospective comparative case series was performed. We evaluated uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity (UIVA), uncorrected near visual acuity (UNVA), predictability, safety, efficacy, and satisfaction after implantation of the same model of trifocal IOL in both eyes (PhysIOL FineVision Pod-F and Micro-F and Rayner RayOne Trifocal). RESULTS: A total of 164 eyes of 82 patients (41 females, 50%) met the inclusion criteria. There were no statistically significant differences in sphere, cylinder, spherical equivalent, UDVA, UIVA, or UNVA between the groups. Postoperative CDVA was slightly better in the control group (logMAR 0.03) than in the AH/SS group (logMAR 0.04) (P: 0.014). There were no statistically significant differences in predictability, safety index, or efficacy index between the groups. Overall subjective satisfaction was good (98.2%). CONCLUSIONS: Visual outcomes and satisfaction are good after implantation of trifocal IOLs in eyes with AH or SS. Therefore, trifocal IOLs should not be ruled out in these patients when no other vitreoretinal disorder is present.


Asunto(s)
Lentes Intraoculares , Enfermedades Orbitales , Facoemulsificación , Femenino , Humanos , Facoemulsificación/efectos adversos , Implantación de Lentes Intraoculares/efectos adversos , Estudios Retrospectivos , Satisfacción del Paciente , Lentes Intraoculares/efectos adversos , Refracción Ocular , Trastornos de la Visión , Diseño de Prótesis , Seudofaquia/complicaciones , Seudofaquia/cirugía
11.
BMC Ophthalmol ; 24(1): 136, 2024 Mar 27.
Artículo en Inglés | MEDLINE | ID: mdl-38532398

RESUMEN

PURPOSE: To determine the distribution of subfoveal choroidal thickness (SFCT) and its associated demographic, ocular, and systemic factors in an elderly population. METHODS: This report is part of the Tehran Geriatric Eye Study (TGES); a population-based cross-sectional study that was conducted on the urban elderly population of Tehran, aged 60 years and above using multi-stage stratified random cluster sampling. Choroidal imaging was performed using Spectralis SD-OCT with enhanced depth imaging mode. RESULTS: The average SFCT was 265.3 ± 25.9 µm (95% CI: 262.8-267.7) in the whole sample. According to the multiple generalized estimating equation (GEE) model, pseudophakia had a statistically significant direct relationship with SFCT (coefficient = 5.69), and history of cerebrovascular accident (CVA) was significantly inversely related to SFCT (coefficient=-4.77). Moreover, there was a significant interaction between age and sex in the average SFCT so that with increasing age, the SFCT increased in men and decreased in women. CONCLUSION: The normal values of SFCT in the present study can be used as a reference database for clinical and research purposes. Age-sex interaction, pseudophakia, and history of CVA were significantly associated with SFCT in the elderly population. It is recommended that these factors be taken into account when interpreting SFCT data.


Asunto(s)
Coroides , Seudofaquia , Masculino , Humanos , Anciano , Femenino , Estudios Transversales , Irán , Tomografía de Coherencia Óptica/métodos
12.
BMC Ophthalmol ; 24(1): 86, 2024 Feb 26.
Artículo en Inglés | MEDLINE | ID: mdl-38409015

RESUMEN

BACKGROUND: To evaluate visual performance after implantation of the TFNT (Acrysof Panoptix, Alcon, Fort Worth, Texas, USA) and CNWT (Clareon Panoptix, Alcon, Fort Worth, Texas, USA) intraocular lens (IOL), and compare the lens shape observed by scanning electron microscope (SEM). METHODS: Eighteen patients (18 eyes) received implantation of the CNWT and Twenty patients (20 eyes) received implantation of the TFNT. Exclusion criteria were previous ocular surgeries, ocular pathologies, or corneal abnormalities. Intervention or Observational Procedure(s): Postoperative examination at 1 months including manifest refraction; evaluation of refractive error, distance-corrected visual acuity (DCVA) at 5 m, 1 m, 70 cm, 50 cm, 40 cm, and 30 cm, slit-lamp examination; defocus curve testing; contrast sensitivity (CS) was performed. The lens shape of the TFNT and the CNWT was examined under SEM. RESULTS: Mean spherical equivalent was 0.11 ± 0.41 D (CNWT group) and 0.12 ± 0.34 D (TFNT group) 1 month postoperation. DCVA and defocus curve showed no significant difference between the two groups. CS was significantly higher in CNWT group than TFNT group at spatial frequencies of 6 cycles per degree (cpd). Observation of the IOL with a scanning electron microscope (SEM) revealed that CNWT group had improved diffraction structure and edge processing accuracy compared to TFNT group. CONCLUSION: There was no significant difference between the two groups in the defocus curve and visual acuity at all distances. CS was better in the CNWT group than in the TFNT group. IOL surface features may affect CS.


Asunto(s)
Lentes Intraoculares , Facoemulsificación , Humanos , Microscopía Electrónica de Rastreo , Implantación de Lentes Intraoculares , Seudofaquia/cirugía , Visión Binocular , Refracción Ocular , Diseño de Prótesis
13.
J Cataract Refract Surg ; 50(6): 578-584, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38305420

RESUMEN

PURPOSE: To evaluate subjective and objective outcomes after combined implantation of an extended depth-of-focus (EDOF) intraocular lens (IOL) and a combined technology multifocal lens (CT-IOL). SETTING: 2 clinical practices (Carolina Eyecare Physicians, Center For Sight) in the United States. DESIGN: Prospective, unmasked, multicenter, nonrandomized bilateral eye study. METHODS: Patients interested in reducing their dependence on spectacles were implanted with an EDOF IOL in the dominant eye and a CT-IOL in the nondominant eye. Refractive and visual acuity (VA) data at various distances (4 m, 66 cm, 40 cm, and 33 cm) were collected 3 months postsurgery, along with the distance-corrected binocular defocus curve and responses to questionnaires related to spectacle independence, visual disturbances, and overall visual function. RESULTS: Data from 37 participants were analyzed. The distance-corrected binocular defocus curve showed a mean VA better than 0.1 logMAR (20/25) at all vergences from +1.00 to -2.50 diopters (D). 36 participants (97%) had an uncorrected binocular VA of 0.3 logMAR or better, at all test distances. 70% of participants (26/37) reported never wearing spectacles at any distance, and 84% (31/37) were "completely" or "mostly" satisfied with their overall vision after surgery. Halos were the disturbance reported most frequently and reported as most bothersome, with difficulty driving at night the most common visual function issue. Difficulty reading was the next most reported issue. Overall eyesight was rated as "excellent" or "good" by 92% (34/37) of participants. CONCLUSIONS: This combined EDOF/CT-IOL approach was well-tolerated by participants and provided some potential benefits relative to bilateral implantation of either lens.


Asunto(s)
Implantación de Lentes Intraoculares , Facoemulsificación , Presbiopía , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Presbiopía/fisiopatología , Presbiopía/cirugía , Visión Binocular/fisiología , Masculino , Femenino , Persona de Mediana Edad , Anciano , Refracción Ocular/fisiología , Seudofaquia/fisiopatología , Satisfacción del Paciente , Lentes Intraoculares , Encuestas y Cuestionarios , Lentes Intraoculares Multifocales , Predominio Ocular/fisiología , Percepción de Profundidad/fisiología , Diseño de Prótesis
14.
J Cataract Refract Surg ; 50(6): 644-650, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38334413

RESUMEN

This is a pooled analysis from 2 phase III clinical trials investigating a water-free topical cyclosporine 0.1% for the treatment of moderate to severe dry eye. The analyses included 1162 patients: 35% with cataract, 20% with pseudophakia, and 45% without cataract. Demographics or baseline characteristics were comparable across groups except for age and vision. The cyclosporine-treated patients achieved large mean improvements from baseline by day 15: -3.7 in patients without cataract, -3.2 in patients with cataract, and -3.1 in pseudophakic patients. These improvements were statistically significantly higher compared with the respective vehicle groups. In the cataract subgroup, 59% of patients treated with cyclosporine achieved ≥3 grade improvements in corneal staining score, as early as day 15. The magnitude of the effect and early onset of action make this new cyclosporine solution a promising candidate for preoperative management of ocular surface in patients undergoing cataract surgery.


Asunto(s)
Ciclosporina , Síndromes de Ojo Seco , Inmunosupresores , Soluciones Oftálmicas , Seudofaquia , Humanos , Ciclosporina/administración & dosificación , Síndromes de Ojo Seco/tratamiento farmacológico , Soluciones Oftálmicas/administración & dosificación , Femenino , Masculino , Anciano , Inmunosupresores/administración & dosificación , Seudofaquia/fisiopatología , Catarata/complicaciones , Persona de Mediana Edad , Agudeza Visual/fisiología , Método Doble Ciego , Administración Tópica , Resultado del Tratamiento , Córnea
15.
J Cataract Refract Surg ; 50(6): 585-590, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38350145

RESUMEN

PURPOSE: To evaluate visual and refractive outcomes, as well as patient satisfaction after bilateral implantation of an enhanced monofocal intraocular lens (IOL) with emmetropia as a target refraction. SETTING: San Carlos Hospital, Madrid, Spain. DESIGN: Prospective, monocentric, noncomparative study. METHODS: Adults 21 years or older suitable for cataract surgery and with corneal astigmatism <1.50 diopters (D) were bilaterally implanted with the RayOne EMV IOL and followed up for 3 months. Outcomes measures included refraction, monocular and binocular uncorrected distance visual acuity, corrected distance visual acuity (CDVA), uncorrected intermediate visual acuity, distance-corrected intermediate visual acuity (DCIVA), and defocus curve, aberrometry, and satisfaction. Visual symptoms were assessed using the CatQuest-9SF questionnaire. RESULTS: 50 eyes of 25 patients were included. At month 3, the mean manifest spherical equivalent was -0.39 ± 0.28 D, with all eyes within 1.00 D. Binocularly, uncorrected, at distance, 68% of patients could read ≤0.0 logMAR and 95% ≤0.2 logMAR; at intermediate 59% of patients could read ≤0.1 and 100% ≤0.2 logMAR. Mean monocular CDVA was -0.03 ± 0.06 logMAR and mean monocular DCIVA was 0.28 ± 0.07 logMAR. Binocular defocus curve demonstrated a visual acuity ≤0.2 logMAR over a 2 D range from +1.00 D to -1.25 D. Satisfaction was good in 96% of patients. CONCLUSIONS: Bilateral implantation of an enhanced monofocal IOL with emmetropia as a target provided excellent binocular CDVA and good DCIVA, with a high level of satisfaction.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Satisfacción del Paciente , Facoemulsificación , Seudofaquia , Refracción Ocular , Visión Binocular , Agudeza Visual , Humanos , Estudios Prospectivos , Agudeza Visual/fisiología , Refracción Ocular/fisiología , Seudofaquia/fisiopatología , Masculino , Femenino , Visión Binocular/fisiología , Persona de Mediana Edad , Anciano , Encuestas y Cuestionarios , Diseño de Prótesis , Adulto , Emetropía/fisiología , Aberrometría
16.
J Cataract Refract Surg ; 50(6): 591-598, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38350162

RESUMEN

PURPOSE: To assess the effect of residual sphere on vision and satisfaction in pseudophakic patients. SETTING: Private clinics, United Kingdom. DESIGN: Retrospective case series. METHODS: A multivariate model evaluated the effect of 1-month residual sphere on outcomes of pseudophakic patients. Odds ratios (ORs) were calculated to assess the relative risk of not achieving ≥20/20 monocular uncorrected distance visual acuity (UDVA), ≥20/50 uncorrected near visual acuity (UNVA), and not being satisfied with vision. ORs were assessed for residual sphere -1.00 to +1.00 diopter (D) in quarter-diopter steps, using 0.00 D as a reference. RESULTS: The analysis included 38 828 multifocal and 11 571 monofocal intraocular lenses (IOLs). The residual myopic sphere ≤-0.25 D and hyperopic sphere ≥+0.50 D had a clinically meaningful effect on UDVA. Although monofocal IOLs had an improvement in UNVA with every additional 0.25 D of myopia, the change in ORs with increasing myopia was not significant for multifocal IOLs. The mean improvement in UNVA comparing eyes with 0.00 D and -1.00 D sphere was 0.26 logMAR for monofocal and 0.03 logMAR for multifocal IOLs. Low near-addition IOLs had a slightly higher gain in UNVA with increasing myopia, but the gain was not as substantial as with monofocal IOLs. The effect of ametropia on satisfaction was more pronounced for multifocal IOLs. For every 0.25 D of residual myopia, there was >25% increase in dissatisfied patients. CONCLUSIONS: Although myopia improved UNVA in eyes with monofocal IOL, multifocal IOLs did not benefit from residual myopia. Multifocal IOL patients desiring distance vision should be targeted closest to emmetropia, even if it means targeting slight hyperopia.


Asunto(s)
Implantación de Lentes Intraoculares , Lentes Intraoculares , Lentes Intraoculares Multifocales , Satisfacción del Paciente , Facoemulsificación , Seudofaquia , Agudeza Visual , Humanos , Agudeza Visual/fisiología , Estudios Retrospectivos , Seudofaquia/fisiopatología , Femenino , Masculino , Anciano , Persona de Mediana Edad , Miopía/fisiopatología , Hiperopía/fisiopatología , Refracción Ocular/fisiología
17.
J Cataract Refract Surg ; 50(6): 605-610, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38350232

RESUMEN

PURPOSE: To evaluate which secondary intraocular lens (IOL) implantation technique was more successful in achieving the best postoperative results and refractive outcomes between retropupillary iris-claw IOL (ICIOL) and flanged intrascleral IOL (FIIOL) fixation with the Yamane technique. SETTING: Eye Clinic of the University of Trieste, Trieste, Italy. DESIGN: Retrospective observational study. METHODS: 116 eyes of 110 patients who underwent ICIOL or FIIOL were analyzed. Patients with follow-up shorter than 6 months or with incomplete clinical data were excluded. Collected data included demographics, ocular comorbidity, indication of surgery, intraocular pressure, early (≤1 month) and late (>1 month) postoperative complications, corrected distance visual acuity (CDVA), and manifest refraction at the last follow-up visit. RESULTS: 50% (n = 58) of eyes underwent FIIOL and 50% (n = 58) ICIOL implantation for aphakia (n = 44, 38%) and IOL dislocation (n = 72, 62%). No statistically significant differences in demographics, comorbidity, follow-up duration, postoperative complications, and surgical indications were found. The refractive prediction error (RPE) was 0.69 ± 0.94 diopter (D) in the FIIOL group and 0.21 ± 0.75 D in the ICIOL group ( P = .03), indicating residual hyperopia after both techniques. RPE, mean absolute error, and median absolute error were higher in the FIIOL group ( P = .003). ICIOL implantation was more successful in obtaining a RPE between -0.50 D and +0.50 D (52% of ICIOL, n = 30, and 31% of FIIOL, n = 18). CONCLUSIONS: Both techniques were effective in increasing preoperative CDVA with no statistical difference between them. Although complication rates did not significantly differ, the FIIOL group exhibited less predictable refractive outcomes. Adjusting the dioptric power of the 3-piece IOL, as performed in ciliary sulcus implantation, to prevent myopic shift, is not recommended.


Asunto(s)
Iris , Implantación de Lentes Intraoculares , Lentes Intraoculares , Refracción Ocular , Agudeza Visual , Humanos , Estudios Retrospectivos , Agudeza Visual/fisiología , Implantación de Lentes Intraoculares/métodos , Iris/cirugía , Masculino , Femenino , Refracción Ocular/fisiología , Persona de Mediana Edad , Anciano , Estudios de Seguimiento , Facoemulsificación , Seudofaquia/fisiopatología , Complicaciones Posoperatorias , Adulto , Resultado del Tratamiento
18.
BMC Ophthalmol ; 24(1): 72, 2024 Feb 16.
Artículo en Inglés | MEDLINE | ID: mdl-38365667

RESUMEN

PURPOSE: To compare the rotational stability of a monofocal and a diffractive multifocal toric intraocular lens(IOLs) with identical design and material. METHODS: This prospective study enrolled patients who underwent plate-haptic toric IOL (AT TORBI 709 M and AT LISA 909 M) implantation. Propensity score matching (PSM) was performed to balance baseline factors. Follow-up examinations were conducted at 1 h, 1 day, 3 days, 1 week, 2 weeks, 1 month, and 3 months postoperatively. A linear mixed model of repeated measures was used to investigate the changes in IOL rotation over time. A 2-week timeframe was utilized to assess differences in IOL rotation between the two groups. RESULT: After PSM, a total of 126 eyes were selected from each group for further analysis. Postoperatively, the time course of IOL rotation change in the two groups remained consistent, with the greatest rotation occurring between 1 h and 1 day postoperatively. At the 2-week postoperative mark, the monofocal toric IOL exhibited a higher degree of rotation compared to the multifocal toric IOL (5.40 ± 7.77° vs. 3.53 ± 3.54°, P = 0.015). In lens thickness(LT) ≥ 4.5 mm and white-to-white distance(WTW) ≥ 11.6 mm subgroups, the monofocal toric IOL rotated greater than the multifocal toric IOL (P = 0.026 and P = 0.011, respectively). CONCLUSION: The diffractive multifocal toric IOL exhibits superior rotational stability compared to the monofocal toric IOL, especially in subgroups LT ≥ 4.5 mm and WTW ≥ 11.6 mm. Moreover, the time course of IOL rotation change is consistent for both, with the maximum rotation occurring between 1 h and 1 day postoperatively.


Asunto(s)
Astigmatismo , Lentes Intraoculares , Facoemulsificación , Humanos , Implantación de Lentes Intraoculares , Estudios Prospectivos , Seudofaquia/cirugía , Agudeza Visual , Puntaje de Propensión , Astigmatismo/cirugía , Refracción Ocular
19.
Int Ophthalmol ; 44(1): 43, 2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38334834

RESUMEN

PURPOSE: To examine the ophthalmic data from a large database of people attending a general medical survey institute, and to investigate ophthalmic findings of the eye and its adnexa, including differences in age and sex. METHODS: Retrospective analysis including medical data of all consecutive individuals whose ophthalmic data and the prevalences of ocular pathologies were extracted from a very large database of subjects examined at a single general medical survey institute. RESULTS: Data were derived from 184,589 visits of 3676 patients (mean age 52 years, 68% males). The prevalence of the following eye pathologies were extracted. Eyelids: blepharitis (n = 4885, 13.3%), dermatochalasis (n = 4666, 12.7%), ptosis (n = 677, 1.8%), ectropion (n = 73, 0.2%), and xanthelasma (n = 160, 0.4%). Anterior segment: pinguecula (n = 3368, 9.2%), pterygium (n = 852, 2.3%), and cataract or pseudophakia (n = 9381, 27.1%). Cataract type (percentage of all phakic patients): nuclear sclerosis (n = 8908, 24.2%), posterior subcapsular (n = 846, 2.3%), and capsular anterior (n = 781, 2.1%). Pseudophakia was recorded for 697 patients (4.6%), and posterior subcapsular opacification for 229 (0.6%) patients. Optic nerve head (ONH): peripapillary atrophy (n = 4947, 13.5%), tilted disc (n = 3344, 9.1%), temporal slope (n = 410, 1.1%), ONH notch (n = 61, 0.2%), myelinated nerve fiber layer (n = 94, 0.3%), ONH drusen (n = 37, 0.1%), optic pit (n = 3, 0.0%), and ON coloboma (n = 4, 0.0%). Most pathologies were more common in males except for ONH, and most pathologies demonstrated a higher prevalence with increasing age. CONCLUSIONS: Normal ophthalmic data and the prevalences of ocular pathologies were extracted from a very large database of subjects seen at a single medical survey institute.


Asunto(s)
Catarata , Seudofaquia , Adulto , Masculino , Humanos , Persona de Mediana Edad , Femenino , Prevalencia , Estudios Retrospectivos , Nervio Óptico
20.
BMC Ophthalmol ; 24(1): 40, 2024 Jan 25.
Artículo en Inglés | MEDLINE | ID: mdl-38273262

RESUMEN

BACKGROUND: This study aimed to compare the corneal high-order aberrations and surgically induced astigmatism between the clear corneal incision and limbus tunnel incision for posterior chamber implantable collamer lens (ICL/TICL) implantation. METHODS: A total of 127 eyes from 73 myopic patients underwent ICL V4c implantation, with 70 eyes receiving clear corneal incisions and 57 eyes receiving limbus tunnel incisions. The anterior and back corneal surfaces were measured and the Root Mean Square of all activated aberrations (TRMS) was calculated, including higher-order aberration (HOA RMS), spherical aberration Z40, coma coefficients (Coma RMS) Z3-1 Z31, and surgically induced astigmatism (SIA). The measurements were taken preoperatively and postoperatively at 1 day, 1 week, and 1, 3, and 6 months. In this study, the corneal higher-order aberration was estimated as the Zernike coefficient calculated up to 5th order. The measurements were taken at a maximum diameter of 6.5 mm using Pentacam. RESULTS: One week after the operation, the corneal back Z31 of the clear corneal incision group was 0.06 ± 0.06, while the limbus tunnel incision group showed a measurement of 0.05 ± 0.06 (p = 0.031). The corneal back Z40 of the clear corneal incision group was -0.02 ± 0.25, compared to -0.04 ± 0.21 in the limbus tunnel incision group (p = 0.01). One month after the operation, the corneal back SIA of the clear corneal incision group was 0.11 ± 0.11, compared to 0.08 ± 0.11of the limbus tunnel incision group (p = 0.013), the corneal total SIA of the clear corneal incision group was 0.33 ± 0.30, compared to 0.15 ± 0.16 in the limbus tunnel incision group (p = 0.004); the clear corneal incision group exhibited higher levels of back astigmatism and total SIA than the limbus tunnel incision in the post-operation one month period. During the 6- month post-operative follow-up period, no significant difference in Z31, Z40, and other HOA RMS data was observed between the two groups. The total SIA of the corneal incision group and the limbus tunnel incision group were 0.24 ± 0.14 and 0.33 ± 0.32, respectively (p = 0.393), showing no significant difference between the two groups 6 months after the operation. CONCLUSION: Our data showed no significant difference in the high-order aberration and SIA between clear corneal incision and limbus tunnel incision up to 6 months after ICL-V4c implantation.


Asunto(s)
Astigmatismo , Humanos , Astigmatismo/etiología , Astigmatismo/cirugía , Implantación de Lentes Intraoculares , Coma/cirugía , Córnea/cirugía , Seudofaquia/cirugía
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA