Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.072
Filtrar
1.
J Vis Exp ; (208)2024 Jun 14.
Artículo en Inglés | MEDLINE | ID: mdl-38949379

RESUMEN

The use of telemetry techniques to better understand the behavior and survival of juvenile American shad (Alosa sapidissima), as they migrate through hydropower systems, has been challenging because shad are widely known to be particularly sensitive to handling. The goal of this study was to develop a tagging protocol using a new, acoustic micro transmitter that minimizes the detrimental effects of the tagging process and maximizes post-tagging survival of juvenile American shad. Limiting out-of-water handling and the use of brackish saltwater (7.5 parts per thousand) before and after tagging improved survival for shad tagged using a simple pectoral implantation method. This protocol provides a detailed, step-by-step procedure for tagging juvenile shad with acoustic transmitters. Fish tagged using this procedure and held in the laboratory for 60 days had an 81.5% survival rate, compared to 70% for their untagged counterparts. The successful tagging and handling practices developed in this study could be applied to field telemetry studies of juvenile shad and other sensitive species.


Asunto(s)
Acústica , Telemetría , Animales , Acústica/instrumentación , Telemetría/métodos , Telemetría/instrumentación , Sistemas de Identificación Animal/métodos , Sistemas de Identificación Animal/instrumentación
2.
J Neural Eng ; 21(3)2024 Jun 21.
Artículo en Inglés | MEDLINE | ID: mdl-38861967

RESUMEN

Objective. We intend to chronically restore somatosensation and provide high-fidelity myoelectric control for those with limb loss via a novel, distributed, high-channel-count, implanted system.Approach.We have developed the implanted Somatosensory Electrical Neurostimulation and Sensing (iSens®) system to support peripheral nerve stimulation through up to 64, 96, or 128 electrode contacts with myoelectric recording from 16, 8, or 0 bipolar sites, respectively. The rechargeable central device has Bluetooth® wireless telemetry to communicate to external devices and wired connections for up to four implanted satellite stimulation or recording devices. We characterized the stimulation, recording, battery runtime, and wireless performance and completed safety testing to support its use in human trials.Results.The stimulator operates as expected across a range of parameters and can schedule multiple asynchronous, interleaved pulse trains subject to total charge delivery limits. Recorded signals in saline show negligible stimulus artifact when 10 cm from a 1 mA stimulating source. The wireless telemetry range exceeds 1 m (direction and orientation dependent) in a saline torso phantom. The bandwidth supports 100 Hz bidirectional update rates of stimulation commands and data features or streaming select full bandwidth myoelectric signals. Preliminary first-in-human data validates the bench testing result.Significance.We developed, tested, and clinically implemented an advanced, modular, fully implanted peripheral stimulation and sensing system for somatosensory restoration and myoelectric control. The modularity in electrode type and number, including distributed sensing and stimulation, supports a wide variety of applications; iSens® is a flexible platform to bring peripheral neuromodulation applications to clinical reality. ClinicalTrials.gov ID NCT04430218.


Asunto(s)
Electromiografía , Humanos , Electromiografía/métodos , Electrodos Implantados , Tecnología Inalámbrica/instrumentación , Telemetría/instrumentación , Telemetría/métodos , Diseño de Equipo/métodos , Músculo Esquelético/fisiología , Músculo Esquelético/inervación
3.
Scand Cardiovasc J ; 58(1): 2353069, 2024 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-38794854

RESUMEN

OBJECTIVES: Atrial fibrillation (AF) is a common early arrhythmia after heart valve surgery that limits physical activity. We aimed to evaluate the criterion validity of the Apple Watch Series 5 single-lead electrocardiogram (ECG) for detecting AF in patients after heart valve surgery. DESIGN: We enrolled 105 patients from the University Hospital of North Norway, of whom 93 completed the study. All patients underwent single-lead ECG using the smartwatch three times or more daily on the second to third or third to fourth postoperative day. These results were compared with continuous 2-4 days ECG telemetry monitoring and a 12-lead ECG on the third postoperative day. RESULTS: On comparing the Apple Watch ECGs with the ECG monitoring, the sensitivity and specificity to detect AF were 91% (75, 100) and 96% (91, 99), respectively. The accuracy was 95% (91, 99). On comparing Apple Watch ECG with a 12-lead ECG, the sensitivity was 71% (62, 100) and the specificity was 92% (92, 100). CONCLUSION: The Apple smartwatch single-lead ECG has high sensitivity and specificity, and might be a useful tool for detecting AF in patients after heart valve surgery.


Asunto(s)
Fibrilación Atrial , Frecuencia Cardíaca , Valor Predictivo de las Pruebas , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/fisiopatología , Masculino , Estudios Prospectivos , Femenino , Anciano , Persona de Mediana Edad , Reproducibilidad de los Resultados , Noruega , Factores de Tiempo , Aplicaciones Móviles , Resultado del Tratamiento , Electrocardiografía Ambulatoria/instrumentación , Telemetría/instrumentación , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Dispositivos Electrónicos Vestibles , Electrocardiografía , Válvulas Cardíacas/cirugía , Válvulas Cardíacas/fisiopatología
4.
J Pharmacol Toxicol Methods ; 127: 107517, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38797367

RESUMEN

INTRODUCTION: Rat telemetry is the assay of choice to assess the potential effects of novel drug candidates on cardiovascular parameters during early drug discovery. Telemetry device implantation can be combined with venous catheter and access button implantation when intravenous administration of the drug substance is required. METHODS: Rats (Sprague Dawley or Han Wistar) were implanted with telemetry devices for arterial blood pressure measurement using either direct aortic catheterisation (n = 131) or aortic catheterisation via the femoral artery (n = 17). Bipolar leads for ECG recording were also implanted in some of the animals (n = 102). Femoral vein catheters and access buttons were implanted as a separate surgery after the initial telemetry implantation (n = 43). RESULTS: 128 animals (86%) were implanted successfully with telemetry devices without any notable surgical or post-surgical problems. When considering the 2 different catheterisation methods separately, the success rate of the direct aortic approach was 88% compared to 76% with the aortic placement via the femoral artery. Lameness was the most common post-surgical problem. Blood loss during surgery and ischaemic patches on the tail were also observed at a low incidence with the direct aortic approach. Catheter pull-out occurred in some rats before the first signal check reducing the overall success rate for blood pressure measurement using the direct aortic approach to 85%. A 95% success rate was observed for catheter and access button implantation. DISCUSSION: A high success rate is possible when implanting telemetry devices in rats with and without venous catheters and access buttons. We have attempted to provide solutions to problems and describe refinements to the procedure which may further improve surgical outcomes.


Asunto(s)
Ratas Sprague-Dawley , Ratas Wistar , Telemetría , Animales , Telemetría/métodos , Telemetría/instrumentación , Ratas , Masculino , Arteria Femoral/cirugía , Presión Sanguínea/efectos de los fármacos , Electrocardiografía/métodos , Evaluación Preclínica de Medicamentos/métodos
5.
J Comp Eff Res ; 13(6): e240008, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38602503

RESUMEN

Aim: Patients with ischemic stroke (IS) commonly undergo monitoring to identify atrial fibrillation with mobile cardiac outpatient telemetry (MCOT) or implantable loop recorders (ILRs). The authors compared readmission, healthcare cost and survival in patients monitored post-stroke with either MCOT or ILR. Materials & methods: The authors used claims data from Optum's de-identified Clinformatics® Data Mart Database to identify patients with IS hospitalized from January 2017 to December 2020 who were prescribed ambulatory cardiac monitoring via MCOT or ILR. They compared the costs associated with the initial inpatient visit as well as the rate and causes of readmission, survival and healthcare costs over the following 18 months. Datasets were balanced using patient baseline and hospitalization characteristics. Multivariable generalized linear gamma regression was used for cost comparisons. Cox proportional hazard regression was used for survival and readmission analysis. Sub-cohorts were analyzed based on the severity of the index IS. Results: In 2244 patients, readmissions were significantly lower in the MCOT monitored group (30.2%) compared with the ILR group (35.4%) (hazard ratio [HR] 1.23; 95% CI: 1.04-1.46). Average cost over 18 months starting with the index IS was $27,429 (USD) lower in the MCOT group (95% CI: $22,353-$32,633). Survival difference bordered on statistical significance and trended to lower mortality in MCOT (8.9%) versus ILR (11.3%) (HR 1.30; 95% CI: 1:00-1.69), led by significance in patients with complications or comorbidities with the index event (MCOT 7.5%, ILR 11.5%; HR 1.62; 95% CI: 1.11-2.36). Conclusion: The use of MCOT versus ILR as the primary monitor following IS was associated with significant decreases in readmission, lower costs for the initial IS and total care over the next 18 months, significantly lower mortality for patients with complications and comorbidities at the index stroke, and a trend toward improved survival across all patients.


Asunto(s)
Readmisión del Paciente , Telemetría , Humanos , Masculino , Femenino , Anciano , Telemetría/economía , Telemetría/métodos , Telemetría/instrumentación , Readmisión del Paciente/estadística & datos numéricos , Readmisión del Paciente/economía , Persona de Mediana Edad , Fibrilación Atrial/economía , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Costos de la Atención en Salud/estadística & datos numéricos , Accidente Cerebrovascular/economía , Accidente Cerebrovascular/mortalidad , Accidente Cerebrovascular/diagnóstico , Accidente Cerebrovascular Isquémico/economía , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/mortalidad , Estudios Retrospectivos , Anciano de 80 o más Años
6.
Singapore Med J ; 65(7): 370-379, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38449074

RESUMEN

INTRODUCTION: Prolonged cardiac monitoring after cryptogenic stroke or embolic stroke of undetermined source (ESUS) is necessary to identify atrial fibrillation (AF) that requires anticoagulation. Wearable devices may improve AF detection compared to conventional management. We aimed to review the evidence for the use of wearable devices in post-cryptogenic stroke and post-ESUS monitoring. METHODS: We performed a systematic search of PubMed, EMBASE, Scopus and clinicaltrials.gov on 21 July 2022, identifying all studies that investigated the use of wearable devices in patients with cryptogenic stroke or ESUS. The outcomes of AF detection were analysed. Literature reports on electrocardiogram (ECG)-based (external wearable, handheld, patch, mobile cardiac telemetry [MCT], smartwatch) and photoplethysmography (PPG)-based (smartwatch, smartphone) devices were summarised. RESULTS: A total of 27 relevant studies were included (two randomised controlled trials, seven prospective trials, 10 cohort studies, six case series and two case reports). Only four studies compared wearable technology to Holter monitoring or implantable loop recorder, and these studies showed no significant differences on meta-analysis (odds ratio 2.35, 95% confidence interval [CI] 0.74-7.48, I 2 = 70%). External wearable devices detected AF in 20.7% (95% CI 14.9-27.2, I 2 = 76%) of patients and MCT detected new AF in 9.6% (95% CI 7.4%-11.9%, I 2 = 56%) of patients. Other devices investigated included patch sensors, handheld ECG recorders and PPG-based smartphone apps, which demonstrated feasibility in the post-cryptogenic stroke and post-ESUS setting. CONCLUSION: Wearable devices that are ECG or PPG based are effective for paroxysmal AF detection after cryptogenic stroke and ESUS, but further studies are needed to establish how they compare with Holter monitors and implantable loop recorder.


Asunto(s)
Fibrilación Atrial , Accidente Cerebrovascular Embólico , Dispositivos Electrónicos Vestibles , Humanos , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/complicaciones , Electrocardiografía/instrumentación , Electrocardiografía Ambulatoria/instrumentación , Accidente Cerebrovascular Embólico/etiología , Accidente Cerebrovascular Embólico/diagnóstico , Accidente Cerebrovascular Isquémico/diagnóstico , Accidente Cerebrovascular Isquémico/complicaciones , Monitoreo Fisiológico/instrumentación , Monitoreo Fisiológico/métodos , Fotopletismografía/instrumentación , Telemetría/instrumentación
7.
Cardiovasc Revasc Med ; 64: 15-20, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38388248

RESUMEN

BACKGROUND: Conduction disturbances are a common complication of transcatheter aortic valve replacement (TAVR). Mobile Cardiac Telemetry (MCT) allows for continuous monitoring with near "real time" alerts and has allowed for timely detection of conduction abnormalities and pacemaker placement in small trials. A standardized, systematic approach utilizing MCT devices post TAVR has not been widely implemented, leading to variation in use across hospital systems. OBJECTIVES: Our aim was to evaluate the utility of a standardized, systematic approach utilizing routine MCT to facilitate safe and earlier discharge by identifying conduction disturbances requiring permanent pacemaker (PPM) placement. We also sought to assess the occurrence of actionable arrhythmias in post-TAVR patients. METHODS: Using guidance from the JACC Scientific Expert Panel, a protocol was implemented starting in December 2019 to guide PPM placement post-TAVR across our health system. All patients who underwent TAVR from December 2019 to June 2021 across four hospitals within Northwell Health, who did not receive or have a pre-existing PPM received an MCT device at discharge and were monitored for 30 days. Clinical and follow-up data were collected and compared to pre initiative patients. RESULTS: During the initiative 693 patients were monitored with MCT upon discharge, 21 of whom required PPM placement. Eight of these patients had no conduction abnormality on initial or discharge ECG. 59 (8.6 %) patients were found to have new atrial fibrillation or flutter via MCT monitoring. There were no adverse events in the initiative group. Prior to the initiative, 1281 patients underwent TAVR over a one-year period. The initiative group had significantly shorter length of stay than pre-initiative patients (2.5 ± 4.5 vs 3.0 ± 3.8 days, p < 0.001) and lower overall PPM placement rate within 30 days post-TAVR (16 % vs 20.5 %, P = 0.0125). CONCLUSIONS: In our study, implementation of a standardized, systematic approach utilizing MCT in post-TAVR patients was safe and allowed for timely detection of conduction abnormalities requiring pacemaker placement. This strategy also detected new atrial fibrillation and flutter. Reduction in post TAVR pacemaker rate and length of stay were also noted although this effect is multifactorial.


Asunto(s)
Estenosis de la Válvula Aórtica , Válvula Aórtica , Arritmias Cardíacas , Estimulación Cardíaca Artificial , Marcapaso Artificial , Valor Predictivo de las Pruebas , Telemetría , Reemplazo de la Válvula Aórtica Transcatéter , Humanos , Reemplazo de la Válvula Aórtica Transcatéter/efectos adversos , Reemplazo de la Válvula Aórtica Transcatéter/instrumentación , Masculino , Femenino , Anciano de 80 o más Años , Anciano , Factores de Tiempo , Resultado del Tratamiento , Telemetría/instrumentación , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiología , Estenosis de la Válvula Aórtica/cirugía , Estenosis de la Válvula Aórtica/fisiopatología , Válvula Aórtica/cirugía , Válvula Aórtica/fisiopatología , Factores de Riesgo , Atención Ambulatoria , Frecuencia Cardíaca , Estudios Retrospectivos , Alta del Paciente , Potenciales de Acción
9.
Sci Rep ; 11(1): 19148, 2021 09 27.
Artículo en Inglés | MEDLINE | ID: mdl-34580323

RESUMEN

Applications on electromagnetic waves in the field of biotelemetry have increased in the latest years, being used to prevent, diagnose, and treatment of several diseases. In this context, biotelemetry allows minimally invasive monitoring of the physiologic, improving comfort and patient care and significantly reducing hospital costs. Aiming to assist the mineral bone density classification, through a radio frequency signal (RF), for a later diagnosis of osteoporosis, Osseus was proposed in 2018. This equipment is a combination of the application of techniques and concepts of several areas such as software, electrical, electronic, computational, and biomedical engineering, developed at a low cost, with easy access to the population, and non-invasive. However, when placed on evaluation, potential improvements were identified to increase the stability of Osseus operation. It is proposed the implementation of improvements in the antennas used by Osseus, aiming its miniaturization, improvement in the reception of the RF signal, and better stability of the equipment's operation. Then, two antennas were built, one of which was used as a project for the second, which is an array. The array showed significant improvements in the radiation parameters relevant to the application, being a candidate to replace the antennas currently in use at Osseus.


Asunto(s)
Tamizaje Masivo/instrumentación , Osteoporosis/diagnóstico , Telemetría/instrumentación , Dispositivos Electrónicos Vestibles , Ingeniería Biomédica , Densidad Ósea , Campos Electromagnéticos , Diseño de Equipo , Humanos , Tamizaje Masivo/métodos , Miniaturización , Programas Informáticos , Telemetría/métodos
10.
Ann Biomed Eng ; 49(10): 2814-2826, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34549342

RESUMEN

Repeated head impact exposure and concussions are common in American football. Identifying the factors associated with high magnitude impacts aids in informing sport policy changes, improvements to protective equipment, and better understanding of the brain's response to mechanical loading. Recently, the Stanford Instrumented Mouthguard (MiG2.0) has seen several improvements in its accuracy in measuring head kinematics and its ability to correctly differentiate between true head impact events and false positives. Using this device, the present study sought to identify factors (e.g., player position, helmet model, direction of head acceleration, etc.) that are associated with head impact kinematics and brain strain in high school American football athletes. 116 athletes were monitored over a total of 888 athlete exposures. 602 total impacts were captured and verified by the MiG2.0's validated impact detection algorithm. Peak values of linear acceleration, angular velocity, and angular acceleration were obtained from the mouthguard kinematics. The kinematics were also entered into a previously developed finite element model of the human brain to compute the 95th percentile maximum principal strain. Overall, impacts were (mean ± SD) 34.0 ± 24.3 g for peak linear acceleration, 22.2 ± 15.4 rad/s for peak angular velocity, 2979.4 ± 3030.4 rad/s2 for peak angular acceleration, and 0.262 ± 0.241 for 95th percentile maximum principal strain. Statistical analyses revealed that impacts resulting in Forward head accelerations had higher magnitudes of peak kinematics and brain strain than Lateral or Rearward impacts and that athletes in skill positions sustained impacts of greater magnitude than athletes in line positions. 95th percentile maximum principal strain was significantly lower in the observed cohort of high school football athletes than previous reports of collegiate football athletes. No differences in impact magnitude were observed in athletes with or without previous concussion history, in athletes wearing different helmet models, or in junior varsity or varsity athletes. This study presents novel information on head acceleration events and their resulting brain strain in high school American football from our advanced, validated method of measuring head kinematics via instrumented mouthguard technology.


Asunto(s)
Traumatismos en Atletas/fisiopatología , Encéfalo/fisiología , Traumatismos Craneocerebrales/fisiopatología , Protectores Bucales , Equipo Deportivo , Telemetría/instrumentación , Adolescente , Fenómenos Biomecánicos , Fútbol Americano , Cabeza , Humanos , Masculino , Instituciones Académicas , Estados Unidos , Dispositivos Electrónicos Vestibles
11.
Ann Biomed Eng ; 49(10): 2760-2776, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34263384

RESUMEN

Instrumented mouthpieces (IM) offer a means of measuring head impacts that occur in sport. Direct measurement of angular head kinematics is preferential for accuracy; however, existing IMs measure angular velocity and differentiate the measurement to calculate angular acceleration, which can limit bandwidth and consume more power. This study presents the development and validation of an IM that uses new, low-power accelerometers for direct measurement of linear and angular acceleration over a broad range of head impact conditions in American football. IM sensor accuracy for measuring six-degree-of-freedom head kinematics was assessed using two helmeted headforms instrumented with a custom-fit IM and reference sensor instrumentation. Head impacts were performed at 10 locations and 6 speeds representative of the on-field conditions associated with injurious and non-injurious impacts in American football. Sensor measurements from the IM were highly correlated with those from the reference instrumentation located at the maxilla and skull center of gravity. Based on pooled data across headform and impact location, R2 ≥ 0.94, mean absolute error (AE) ≤ 7%, and mean relative impact angle ≤ 11° for peak linear and angular acceleration and angular velocity while R2 ≥ 0.90 and mean AE ≤ 7% for kinematic-based injury metrics used in helmet tests.


Asunto(s)
Fútbol Americano , Protectores Bucales , Equipo Deportivo , Aceleración , Fenómenos Biomecánicos , Diseño de Equipo , Cabeza/fisiología , Humanos , Telemetría/instrumentación , Estados Unidos , Dispositivos Electrónicos Vestibles
12.
Ann Biomed Eng ; 49(10): 2791-2804, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34231091

RESUMEN

Wearable devices have been shown to effectively measure the head's movement during impacts in sports like American football. When a head impact occurs, the device is triggered to collect and save the kinematic measurements during a predefined time window. Then, based on the collected kinematics, finite element (FE) head models can calculate brain strain and strain rate, which are used to evaluate the risk of mild traumatic brain injury. To find a time window that can provide a sufficient duration of kinematics for FE analysis, we investigated 118 on-field video-confirmed football head impacts collected by the Stanford Instrumented Mouthguard. The simulation results based on the kinematics truncated to a shorter time window were compared with the original to determine the minimum time window needed for football. Because the individual differences in brain geometry influence these calculations, we included six representative brain geometries and found that larger brains need a longer time window of kinematics for accurate calculation. Among the different sizes of brains, a pre-trigger time of 40 ms and a post-trigger time of 70 ms were found to yield calculations of brain strain and strain rate that were not significantly different from calculations using the original 200 ms time window recorded by the mouthguard. Therefore, approximately 110 ms is recommended for complete modeling of impacts for football.


Asunto(s)
Encéfalo/fisiología , Fútbol Americano/lesiones , Modelos Biológicos , Telemetría/métodos , Aceleración , Traumatismos en Atletas/fisiopatología , Fenómenos Biomecánicos , Lesiones Encefálicas/fisiopatología , Femenino , Análisis de Elementos Finitos , Cabeza , Humanos , Masculino , Protectores Bucales , Equipo Deportivo , Telemetría/instrumentación , Estados Unidos , Dispositivos Electrónicos Vestibles
13.
Eur Surg Res ; 62(4): 271-275, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34082422

RESUMEN

Implantable telemetric transponders for contactless measurement of physiological parameters are often used in animal-based research. After explantation, single-use devices cannot be re-implanted because of non-validated functionality and necessary re-sterilisation. This is disadvantageous because the battery life would enable a second implantation cycle in another animal. To save costs and time taken for the manufacturer's refurbishing process, we validated and implemented a re-sterilisation protocol for single-use transponders using hydrogen peroxide gas. The described protocol was established with models, i.e., for large (n = 7) and small (n = 3) animals, of telemetric device from 2 different manufacturers (Data Science International and EMKA). All transponders, prepared according to the protocol, were previously implanted subcutaneously in the flank of pigs or rats for a duration of 21 days. Our investigations demonstrate that disinfection only is not sufficient against bacterial contamination and that sterility can only be achieved by additional gas sterilisation with hydrogen peroxide. Furthermore, re-implantation of the re-sterilised transponders into pigs caused neither undesired tissue reactions along the transponder nor impairment of the measured values when compared to the first implantation and after necropsy in 4 cases. We were able to demonstrate that, using our protocol, re-implantation of reprocessed single-use telemetric devices can be performed without compromising transponder quality.


Asunto(s)
Equipo Reutilizado , Peróxido de Hidrógeno , Esterilización , Telemetría/instrumentación , Animales , Prótesis e Implantes , Ratas , Porcinos
14.
Ann Biomed Eng ; 49(10): 2886-2900, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34184145

RESUMEN

Impacts to the back of the head due to rearward falls, also referred to as "backfall" events, represent a common source of TBI for athletes and soldiers. A new experimental apparatus is described for replicating the linear and rotational kinematics of the head during backfall events. An anthropomorphic test device (ATD) with a head-borne sensor suite was configured to fall backwards from a standing height, inducing contact between the rear of the head and a ground surface simulant. A pivoting swing arm and release strap were used to generate consistent and realistic head kinematics. Backfall experiments were performed with the ATD fitted with an American football helmet and the resulting linear and rotational head kinematics, as well as calculated injury metrics, compared favorably with those of football players undergoing similar impacts during games or play reconstructions. This test method complements existing blunt impact helmet performance experiments, such as drop tower and pneumatic ram test methods, which may not be able to fully reproduce head-neck-torso kinematics during a backfall event.


Asunto(s)
Accidentes por Caídas , Traumatismos en Atletas/fisiopatología , Traumatismos Craneocerebrales/fisiopatología , Fútbol Americano/lesiones , Modelos Biológicos , Telemetría/instrumentación , Dispositivos Electrónicos Vestibles , Aceleración , Fenómenos Biomecánicos , Cabeza , Dispositivos de Protección de la Cabeza , Humanos , Masculino , Protectores Bucales , Rotación
15.
PLoS Negl Trop Dis ; 15(6): e0009424, 2021 06.
Artículo en Inglés | MEDLINE | ID: mdl-34138849

RESUMEN

Most alphaviruses are mosquito-borne and can cause severe disease in humans and domesticated animals. In North America, eastern equine encephalitis virus (EEEV) is an important human pathogen with case fatality rates of 30-90%. Currently, there are no therapeutics or vaccines to treat and/or prevent human infection. One critical impediment in countermeasure development is the lack of insight into clinically relevant parameters in a susceptible animal model. This study examined the disease course of EEEV in a cynomolgus macaque model utilizing advanced telemetry technology to continuously and simultaneously measure temperature, respiration, activity, heart rate, blood pressure, electrocardiogram (ECG), and electroencephalography (EEG) following an aerosol challenge at 7.0 log10 PFU. Following challenge, all parameters were rapidly and substantially altered with peak alterations from baseline ranged as follows: temperature (+3.0-4.2°C), respiration rate (+56-128%), activity (-15-76% daytime and +5-22% nighttime), heart rate (+67-190%), systolic (+44-67%) and diastolic blood pressure (+45-80%). Cardiac abnormalities comprised of alterations in QRS and PR duration, QTc Bazett, T wave morphology, amplitude of the QRS complex, and sinoatrial arrest. An unexpected finding of the study was the first documented evidence of a critical cardiac event as an immediate cause of euthanasia in one NHP. All brain waves were rapidly (~12-24 hpi) and profoundly altered with increases of up to 6,800% and severe diffuse slowing of all waves with decreases of ~99%. Lastly, all NHPs exhibited disruption of the circadian rhythm, sleep, and food/fluid intake. Accordingly, all NHPs met the euthanasia criteria by ~106-140 hpi. This is the first of its kind study utilizing state of the art telemetry to investigate multiple clinical parameters relevant to human EEEV infection in a susceptible cynomolgus macaque model. The study provides critical insights into EEEV pathogenesis and the parameters identified will improve animal model development to facilitate rapid evaluation of vaccines and therapeutics.


Asunto(s)
Infecciones por Alphavirus/virología , Modelos Animales de Enfermedad , Electroencefalografía , Virus de la Encefalitis Equina del Este , Monitoreo Fisiológico/instrumentación , Telemetría/instrumentación , Aerosoles , Infecciones por Alphavirus/patología , Animales , Presión Sanguínea , Temperatura Corporal , Chlorocebus aethiops , Femenino , Frecuencia Cardíaca , Humanos , Macaca fascicularis , Masculino , Monitoreo Fisiológico/métodos , Actividad Motora , Fenómenos Fisiológicos Respiratorios , Telemetría/métodos , Células Vero
16.
Ann Biomed Eng ; 49(10): 2875-2885, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33893576

RESUMEN

This study sought to evaluate head accelerations in both players involved in a football collision. Players on two opposing Canadian university teams were equipped with helmet mounted sensors during one game per season, for two consecutive seasons. A total of 276 collisions between 58 instrumented players were identified via video and cross-referenced with sensor timestamps. Player involvement (striking and struck), impact type (block or tackle), head impact location (front, back, left and right), and play type were recorded from video footage. While struck players did not experience significantly different linear or rotational accelerations between any play types, striking players had the highest linear and rotational head accelerations during kickoff plays (p ≤ .03). Striking players also experienced greater linear and rotational head accelerations than struck players during kickoff plays (p = .001). However, struck players experienced greater linear and rotational accelerations than striking players during kick return plays (p ≤ .008). Other studies have established that the more severe the head impact, the greater risk for injury to the brain. This paper's results highlight that kickoff play rule changes, as implemented in American college football, would decrease head impact exposure of Canadian university football athletes and make the game safer.


Asunto(s)
Fútbol Americano , Dispositivos de Protección de la Cabeza , Cabeza/fisiología , Equipo Deportivo , Aceleración , Adulto , Fenómenos Biomecánicos , Canadá , Humanos , Masculino , Rotación , Telemetría/instrumentación , Universidades , Dispositivos Electrónicos Vestibles , Adulto Joven
17.
Nat Commun ; 12(1): 1968, 2021 03 30.
Artículo en Inglés | MEDLINE | ID: mdl-33785751

RESUMEN

Wireless battery free and fully implantable tools for the interrogation of the central and peripheral nervous system have quantitatively expanded the capabilities to study mechanistic and circuit level behavior in freely moving rodents. The light weight and small footprint of such devices enables full subdermal implantation that results in the capability to perform studies with minimal impact on subject behavior and yields broad application in a range of experimental paradigms. While these advantages have been successfully proven in rodents that move predominantly in 2D, the full potential of a wireless and battery free device can be harnessed with flying species, where interrogation with tethered devices is very difficult or impossible. Here we report on a wireless, battery free and multimodal platform that enables optogenetic stimulation and physiological temperature recording in a highly miniaturized form factor for use in songbirds. The systems are enabled by behavior guided primary antenna design and advanced energy management to ensure stable optogenetic stimulation and thermography throughout 3D experimental arenas. Collectively, these design approaches quantitatively expand the use of wireless subdermally implantable neuromodulation and sensing tools to species previously excluded from in vivo real time experiments.


Asunto(s)
Neuroestimuladores Implantables , Fenómenos Fisiológicos del Sistema Nervioso , Optogenética/instrumentación , Pájaros Cantores/fisiología , Telemetría/instrumentación , Tecnología Inalámbrica/instrumentación , Animales , Encéfalo/fisiología , Optogenética/métodos , Nervios Periféricos/fisiología , Reproducibilidad de los Resultados , Telemetría/métodos
18.
Nat Biotechnol ; 39(7): 855-864, 2021 07.
Artículo en Inglés | MEDLINE | ID: mdl-33782610

RESUMEN

Vascular complications following solid organ transplantation may lead to graft ischemia, dysfunction or loss. Imaging approaches can provide intermittent assessments of graft perfusion, but require highly skilled practitioners and do not directly assess graft oxygenation. Existing systems for monitoring tissue oxygenation are limited by the need for wired connections, the inability to provide real-time data or operation restricted to surface tissues. Here, we present a minimally invasive system to monitor deep-tissue O2 that reports continuous real-time data from centimeter-scale depths in sheep and up to a 10-cm depth in ex vivo porcine tissue. The system is composed of a millimeter-sized, wireless, ultrasound-powered implantable luminescence O2 sensor and an external transceiver for bidirectional data transfer, enabling deep-tissue oxygenation monitoring for surgical or critical care indications.


Asunto(s)
Monitoreo Fisiológico , Oxígeno/metabolismo , Prótesis e Implantes , Telemetría/instrumentación , Ultrasonido , Animales , Humanos , Ovinos , Procesamiento de Señales Asistido por Computador
19.
Semin Ophthalmol ; 36(4): 310-314, 2021 May 19.
Artículo en Inglés | MEDLINE | ID: mdl-33689562

RESUMEN

Technological advances provide a number of options for glaucoma monitoring outside the office setting, including home-based tonometry and perimetry. This has the potential to revolutionize management of this chronic disease, improve access to care, and enhance patient engagement. Here, we provide an overview of existing technologies for home-based glaucoma monitoring. We also discuss areas for future research and the potential applications of these technologies to telemedicine, which has been brought to the forefront during the ongoing COVID-19 pandemic.


Asunto(s)
Técnicas de Diagnóstico Oftalmológico/tendencias , Glaucoma/diagnóstico , Monitoreo Ambulatorio , Telemedicina/tendencias , Telemetría/instrumentación , Tecnología Biomédica/tendencias , Glaucoma/fisiopatología , Humanos , Presión Intraocular/fisiología , Oftalmología/tendencias , Autocuidado/métodos , Tomografía de Coherencia Óptica/métodos , Tonometría Ocular/métodos , Pruebas del Campo Visual/métodos
20.
Otolaryngol Head Neck Surg ; 165(5): 751-753, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-33650899

RESUMEN

When a patient presents to a clinician with dizziness, it can be difficult for the patient to describe their symptoms in a clear manner, and clinical examination often yields entirely normal results. Ideally, it would be favorable to measure key physiological parameters during their episodes of dizziness. From a clinical perspective, this would allow a more timely and more accurate diagnosis. From a research perspective, it would allow a greater understanding of how the vestibular system malfunctions as a consequence of vestibular disease. The authors of this report have been funded by the UK Medical Research Council to develop and test a novel technology to measure, record, and analyze key physiological parameters provided by the dizzy individual during an episode of dizziness while active in the community. We provide the context to evolving work in this field, the outcome of preliminary studies, and a consideration of future opportunities.


Asunto(s)
Mareo/diagnóstico , Mareo/fisiopatología , Telemetría/instrumentación , Pruebas de Función Vestibular/instrumentación , Diagnóstico Diferencial , Humanos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...