Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 58
Filtrar
1.
ACS Appl Mater Interfaces ; 13(37): 44124-44135, 2021 Sep 22.
Artículo en Inglés | MEDLINE | ID: mdl-34495627

RESUMEN

Although nanoparticles based on Group 8 elements such as Fe and Ru have been developed, not much is known about Os nanoparticles. However, Os-based nanostructures might have potential in various applications including biomedical fields. Therefore, in this study, we synthesized Os-Te nanorods (OsTeNRs) by solvothermal galvanic replacement with Te nanotemplates. We explored the nanozymatic activity of the synthesized OsTeNRs and found that they exhibited superior photothermal conversion and photocatalytic activity. Along with chemotherapy (regorafenib) and immunotherapy, the nanozymatic, photothermal, and photodynamic activities of OsTeNRs were harnessed to develop a pentamodal treatment for hepatocellular carcinoma (HCC); in vitro and in vivo studies demonstrated that the pentamodal therapy could alleviate hypoxia in HCC cells by generating oxygen and reduced unintended drug accumulation in organs. Moreover, bone-marrow toxicity due to regorafenib could be reduced as the drug was released in a sustained manner. Thus, OsTeNRs can be considered as suitable nanotemplates for combinatorial cancer therapy.


Asunto(s)
Antineoplásicos/uso terapéutico , Carcinoma Hepatocelular/tratamiento farmacológico , Portadores de Fármacos/química , Neoplasias Hepáticas/tratamiento farmacológico , Nanotubos/química , Animales , Catálisis , Línea Celular Tumoral , Portadores de Fármacos/síntesis química , Portadores de Fármacos/efectos de la radiación , Masculino , Ratones Endogámicos C57BL , Nanotubos/efectos de la radiación , Osmio/química , Osmio/efectos de la radiación , Compuestos de Fenilurea/uso terapéutico , Fotoquimioterapia , Piridinas/uso terapéutico , Telurio/química , Telurio/efectos de la radiación , Ensayos Antitumor por Modelo de Xenoinjerto
2.
ACS Appl Mater Interfaces ; 13(36): 42357-42369, 2021 Sep 15.
Artículo en Inglés | MEDLINE | ID: mdl-34472848

RESUMEN

Herein, novel rodlike CdTe@MPA-PDA particles based on polydopamine (PDA) loaded with CdTe quantum dots (QDs) capped with mercaptopropionic acid (CdTe@MPA QDs) with atypical chemical features are evaluated as a potential actuator for photothermal therapy and oxidative stress induction. Under mild conditions established for the safe and efficient use of lasers, temperature increases of 10.2 and 7.8 °C, photothermal conversion efficiencies of 37.7 and 26.2%, and specific absorption rates of 99 and 69 W/g were obtained for CdTe@MPA-PDA and traditional PDA particles in water, respectively. The particles were set to interact with the human breast adenocarcinoma cell line MDA-MB-231. A significant cellular uptake with the majority of particles colocalized into the lysosomes was obtained at a concentration of 100 µg/mL after 24 h. Additionally, CdTe@MPA-PDA and CdTe@MPA QDs showed significantly different internalization levels and loading kinetics profiles. For the first time, the thermal lens technique was used to demonstrate the stability of particle-like CdTe@MPA-PDA after heating at pH 7 and their migration within the heating region due to the thermodiffusion effect. However, under acidic pH-type lysosomes, a performance decrease in heating was observed, and the chemical feature of the particles was damaged as well. Besides, the internalized rodlike CdTe@MPA-PDA notably enhanced the induction of oxidative stress compared with PDA alone and CdTe@MPA QDs in MDA-MB-231 cells initiating apoptosis. Combining these effects suggests that after meticulous optimizations of the conditions, the CdTe@MPA-PDA particles could be used as a photothermal agent under mild conditions and short incubation time, allowing cytoplasmatic subcellular localization. On the other hand, the same particles act as cell killers by triggering reactive oxygen species after a longer incubation time and lysosomal subcellular localization due to the pH effect on the chemical morphology features of the CdTe@MPA-PDA particles.


Asunto(s)
Antineoplásicos/farmacología , Estrés Oxidativo/efectos de los fármacos , Fármacos Fotosensibilizantes/farmacología , Puntos Cuánticos/química , Especies Reactivas de Oxígeno/metabolismo , Antineoplásicos/química , Antineoplásicos/efectos de la radiación , Apoptosis/efectos de los fármacos , Compuestos de Cadmio/química , Compuestos de Cadmio/efectos de la radiación , Línea Celular Tumoral , Supervivencia Celular/efectos de los fármacos , Humanos , Indoles/química , Indoles/efectos de la radiación , Luz , Fármacos Fotosensibilizantes/química , Fármacos Fotosensibilizantes/efectos de la radiación , Polímeros/química , Polímeros/efectos de la radiación , Puntos Cuánticos/efectos de la radiación , Telurio/química , Telurio/efectos de la radiación
3.
ACS Appl Mater Interfaces ; 13(24): 27963-27971, 2021 Jun 23.
Artículo en Inglés | MEDLINE | ID: mdl-34110773

RESUMEN

1T-phase transition-metal dichalcogenides (TMDs) nanomaterials are one type of emerging and promising near-infrared II (NIR-II) photothermal agents (PTAs) derived from their distinct metallic electronic structure, but it is still challenging to synthesize these nanomaterials. Herein, PdTe2 nanoparticles (PTNs) with a 1T crystal symmetry and around 50 nm in size are prepared by an electrochemical exfoliation method, and the corresponding photothermal performances irradiated under a NIR-II laser have been explored. The encapsulation of 1,2-distearoyl-sn-glycero-3-phosphoethanolamine-poly(ethylene glycol) (DSPE-PEG) endows PTNs with water solubility, enhanced photothermal stability, and high biocompatibility. Notably, PTN/DSPE-PEG displays a potent absorbance through the NIR-II zone and considerable photothermal conversion efficiency, which is up to 68% when irradiated with a 1060 nm laser. With these unique photothermal properties, excellent in vitro and in vivo tumor inhibition effects of PTN/DSPE-PEG have been achieved under the irradiation of a NIR-II (1060 nm) laser without visible toxicity to normal tissues, suggesting that it is an efficient NIR-II photothermal nanoagent.


Asunto(s)
Antineoplásicos/uso terapéutico , Nanopartículas del Metal/uso terapéutico , Neoplasias/tratamiento farmacológico , Animales , Antineoplásicos/química , Antineoplásicos/efectos de la radiación , Antineoplásicos/toxicidad , Línea Celular Tumoral , Femenino , Interacciones Hidrofóbicas e Hidrofílicas , Rayos Infrarrojos , Nanopartículas del Metal/química , Nanopartículas del Metal/efectos de la radiación , Nanopartículas del Metal/toxicidad , Ratones Endogámicos BALB C , Paladio/química , Paladio/efectos de la radiación , Paladio/uso terapéutico , Paladio/toxicidad , Fosfatidiletanolaminas/química , Terapia Fototérmica , Polietilenglicoles/química , Telurio/química , Telurio/efectos de la radiación , Telurio/uso terapéutico , Telurio/toxicidad
5.
PLoS One ; 14(9): e0221655, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31513591

RESUMEN

We evaluated the durability of cadmium telluride (CdTe) solar cells upon proton beam irradiation as well as the possibility of achieving a dosimeter usable in proton beam therapy by applying 100 MeV of pencil beam scanning (PBS) irradiation. Specifically, a 100 MeV proton PBS beam was applied at irradiation doses of 0, 1012, 1013, 1014, and 1015 cm-2. According to the results, the remaining factors (defined as the ratio of the degraded value to the initial value) of open-circuit voltage (Voc), short-circuit current (Jsc), fill-factor (FF), and efficiency (ƞ) which are solar cell performance parameters, were approximately 89%, 44%, 69%, and 30%, respectively, compared to those of the reference cell (without irradiation) at the highest dose of 1×1015 cm-2. In particular, the conversion efficiency, which is the main factor, was approximately 70% of that of the reference cell even at a high fluence of 1×1014 cm-2. In addition, we observed the projected range of the hydrogen atoms based on the PBS beam energy using the Tool for Particle Simulation software and assessed the amount of fluence accumulated in a CdTe cell. As the energy increased, the fluence accumulated inside the cell tended to decrease owing to the characteristics of the Bragg peak of the proton. Thus, the radiation damage to the cell induced by the proton beam was reduced. The results of this study are expected to provide valuable reference information for research on dosimetry sensors composed of thin-film solar cells, serving as the basis for future application in proton beam therapy with CdTe solar cells.


Asunto(s)
Compuestos de Cadmio/efectos de la radiación , Fuentes Generadoras de Energía , Telurio/efectos de la radiación , Dureza , Fantasmas de Imagen , Protones , Dosis de Radiación , Programas Informáticos , Propiedades de Superficie
6.
Anal Chem ; 91(2): 1260-1268, 2019 01 15.
Artículo en Inglés | MEDLINE | ID: mdl-30543292

RESUMEN

A near-infrared light-activated ratiometric photoelectrochemical aptasensor was fabricated for detection of carcinoembryonic antigen (CEA) coupling with upconversion nanoparticles (UCNPs)-semiconductor nanocrystals-based spatial-resolved technique on a homemade 3D printing device in which a self-regulating integrated electrode was designed for dual signal readout. The as-prepared NaYF4:Yb,Er UCNPs@CdTe nanocrystals were initially assembled on two adjacent photoelectrodes, then CEA aptamer 1 (A1) and capture DNA (CA) were modified onto two working photoelectrodes (WP1 and WP2) through covalent binding, respectively, and then gold nanoparticle-labeled CEA aptamer 2 (Au NP-A2) was immobilized on the surface of functional WP2 for the formation of double-stranded DNA. Upon target CEA introduction, the various concentrations of CEA were captured on the WP1, whereas the binding of the CEA with Au NP-A2 could be released from the WP2 thanks to the highly affinity of CEA toward A2. The dual signal readout with the "signal-off" of WP1 and "signal-on" of WP2 were employed for the spatial-resolved PEC (SR-PEC) strategy to detect CEA as an analytical model. Combining NaYF4:Yb,Er UCNPs@CdTe nanocrystals with spatial-resolved model on 3D printing device, the PEC ratiometric aptasensor based on steric hindrance effect and exciton-plasmon interactions (EPI) exhibited a linear range from 10.0 pg mL-1 to 5.0 ng mL-1 with a limit of detection of 4.8 pg mL-1 under 980 nm illumination. The SR-PEC ratiometric strategy showed acceptable stability and reproducibility with a superior anti-interference ability. This approach can provide the guidance for the design of ratiometric, multiplexed, and point-of-care biosensors.


Asunto(s)
Aptámeros de Nucleótidos/química , Técnicas Biosensibles/métodos , Antígeno Carcinoembrionario/análisis , Puntos Cuánticos/química , Aptámeros de Nucleótidos/genética , Técnicas Biosensibles/instrumentación , Compuestos de Cadmio/química , Compuestos de Cadmio/efectos de la radiación , Antígeno Carcinoembrionario/química , ADN/química , ADN/genética , Técnicas Electroquímicas/instrumentación , Técnicas Electroquímicas/métodos , Electrodos , Europio/química , Europio/efectos de la radiación , Fluoruros/química , Fluoruros/efectos de la radiación , Oro/química , Rayos Infrarrojos , Límite de Detección , Nanopartículas del Metal/química , Hibridación de Ácido Nucleico , Impresión Tridimensional , Puntos Cuánticos/efectos de la radiación , Telurio/química , Telurio/efectos de la radiación , Itrio/química , Itrio/efectos de la radiación
7.
ACS Sens ; 3(9): 1719-1726, 2018 09 28.
Artículo en Inglés | MEDLINE | ID: mdl-30105902

RESUMEN

The unique properties of two-dimensional (2D) materials make them promising candidates for chemical and biological sensing applications. However, most 2D material sensors suffer from extremely long recovery time due to the slow molecular desorption at room temperature. Here, we report an ultrasensitive p-type molybdenum ditelluride (MoTe2) gas sensor for NO2 detection with greatly enhanced sensitivity and recovery rate under ultraviolet (UV) illumination. Specifically, the sensitivity of the sensor to NO2 is dramatically enhanced by 1 order of magnitude under 254 nm UV illumination as compared to that in the dark condition, leading to a remarkable low detection limit of 252 ppt. More importantly, the p-type MoTe2 sensor can achieve full recovery after each sensing cycle well within 160 s at room temperature. Finally, the p-type MoTe2 sensor also exhibits excellent sensing performance to NO2 in ambient air and negligible response to H2O, indicating its great potential in practical applications, such as breath analysis and ambient NO2 detection. Such impressive features originate from the activated interface interaction between the gas molecules and p-type MoTe2 surface under UV illumination. This work provides a promising and easily applicable strategy to improve the performance of the gas sensors based on 2D materials.


Asunto(s)
Gases/análisis , Molibdeno/química , Dióxido de Nitrógeno/análisis , Telurio/química , Técnicas Electroquímicas/métodos , Límite de Detección , Molibdeno/efectos de la radiación , Telurio/efectos de la radiación , Rayos Ultravioleta
8.
Environ Toxicol Pharmacol ; 58: 45-53, 2018 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-29287253

RESUMEN

Improvement of new nanophotocatalysts enable to decompose the pharmaceutical pollutants with the aid of solar energy is of particular importance. In this research, the ability of SnTe photocatalyst for degradation of warfarin was enhanced and the separation difficulties of the used photocatalyst, from solutions was removed by immobilization of the photocatalyst on a suitable porous support. A novel nano-sized photocatalyst was prepared by coupling of SnTe on the surface of SBA-15 support. Characterization of the synthesized photocatalyst (SnTe@SBA-15) was performed by different methods including XRD, TEM, TGA, FT-IR, EDS and BET techniques. The map of constituent elements was also prepared. The results indicated that the activity of SnTe photocatalyst was significantly enhanced after immobilization on the support and lower catalyst dose was needed. The visible light irradiation was more effective than UV irradiation. The degradation process was kinetically fast, and the equilibrium was established within 10 min. Separation of the synthesized photocatalyst from the solution was much easier than the bulk SnTe. The regenerated photocatalyst retained more than 90% of its initial efficiency.


Asunto(s)
Luz , Nanopartículas/efectos de la radiación , Dióxido de Silicio/efectos de la radiación , Telurio/efectos de la radiación , Estaño/efectos de la radiación , Warfarina/química , Contaminantes Químicos del Agua/química , Adsorción , Catálisis , Nanopartículas/química , Fotólisis , Dióxido de Silicio/química , Telurio/química , Estaño/química , Purificación del Agua/métodos
9.
Phys Med Biol ; 62(3): 1032-1045, 2017 02 07.
Artículo en Inglés | MEDLINE | ID: mdl-28081011

RESUMEN

Accurate estimation of distortion-free spectra is important but difficult in various applications, especially for spectral computed tomography. Two key problems must be solved to reconstruct the incident spectrum. One is the acquisition of the detector energy response. It can be calculated by Monte Carlo simulation, which requires detailed modeling of the detector system and a high computational power. It can also be acquired by establishing a parametric response model and be calibrated using monochromatic x-ray sources, such as synchrotron sources or radioactive isotopes. However, these monochromatic sources are difficult to obtain. Inspired by x-ray fluorescence (XRF) spectrum modeling, we propose a feasible method to obtain the detector energy response based on an optimized parametric model for CdZnTe or CdTe detectors. The other key problem is the reconstruction of the incident spectrum with the detector response. Directly obtaining an accurate solution from noisy data is difficult because the reconstruction problem is severely ill-posed. Different from the existing spectrum stripping method, a maximum likelihood-expectation maximization iterative algorithm is developed based on the Poisson noise model of the system. Simulation and experiment results show that our method is effective for spectrum reconstruction and markedly increases the accuracy of XRF spectra compared with the spectrum stripping method. The applicability of the proposed method is discussed, and promising results are presented.


Asunto(s)
Cadmio/normas , Telurio/normas , Tomografía Computarizada por Rayos X/normas , Zinc/normas , Algoritmos , Cadmio/efectos de la radiación , Calibración , Fluorescencia , Sincrotrones , Telurio/efectos de la radiación , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Rayos X , Zinc/efectos de la radiación
10.
J Nucl Cardiol ; 24(2): 672-682, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-26936035

RESUMEN

BACKGROUND: Considering the distinctive characteristics of CZT detectors, automatic quantification of ischemia using normal limits included with software package may deliver suboptimal results for CAD detection. The present study aims to evaluate the benefits of creating normal limits specific to a local population and laboratory protocol. METHODS AND RESULTS: Two groups were selected from patients who had undergone a CZT MPI. Normal limits were generated with the QPS application based on the population with low likelihood of CAD. Using the vendor-supplied and the population-specific normal limits i-TPD and vessel-specific SDS results obtained for patients who had subsequently undergone coronary angiography were compared with coronary angiography data. A weak correlation was observed for low i-TPD (stress TPD minus rest TPD) and SDS values. Both databases gave similar values for the area under the ROC curve concerning i-TPD (0.75 to 0.74) and SDS results (0.72 to 0.75 for the LAD, 0.62 to 0.64 for the LCx, and 0.63 to 0.67 for the RCA). Sensitivity (60%), specificity (78%), and predictive positive (84%) and negative (52%) values were also similar with a diagnostic and prognostic threshold value. CONCLUSION: The use of a population-specific created database did not influence the diagnostic value of thallium-201 MPI QPS results using a CZT camera.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/epidemiología , Imagen de Perfusión Miocárdica/normas , Cintigrafía/normas , Radioisótopos de Talio/normas , Tomografía Computarizada de Emisión de Fotón Único/normas , Cadmio/efectos de la radiación , Femenino , Francia/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Cintigrafía/métodos , Radiofármacos , Valores de Referencia , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Tomografía Computarizada de Emisión de Fotón Único/métodos , Zinc/efectos de la radiación
11.
J Nucl Cardiol ; 24(2): 395-401, 2017 04.
Artículo en Inglés | MEDLINE | ID: mdl-26780528

RESUMEN

BACKGROUND: Attenuation correction (AC) improves the diagnostic outcome of stress-only myocardial perfusion imaging (MPI) using conventional SPECT. Our aim was to determine the value of AC using a cadmium zinc telluride-based (CZT)-SPECT camera. METHODS AND RESULTS: We retrospectively included 107 consecutive patients who underwent stress-optional rest MPI CZT-SPECT/CT. Next, we created three types of images for each patient; (1) only displaying reconstructed data without the CT-based AC (NC), (2) only displaying AC, and (3) with both NC and AC (NC + AC). Next, two experienced physicians visually interpreted these 321 randomized images as normal, equivocal, or abnormal. Image outcome was compared with all hard events over a mean follow-up time of 47.7 ± 9.8 months. The percentage of images interpreted as normal increased from 45% using the NC images to 72% using AC and to 67% using NC + AC images (P < .001). Hard event hazard ratios for images interpreted as normal were not different between using NC and AC (1.01, P = .99), or NC and NC + AC images (0.97, P = .97). CONCLUSIONS: AC lowers the need for additional rest imaging in stress-first MPI using CZT-SPECT, while long-term patient outcome remained identical. Use of AC reduces the need for additional rest imaging, decreasing the mean effective dose by up to 1.2 mSv.


Asunto(s)
Artefactos , Prueba de Esfuerzo/instrumentación , Aumento de la Imagen/métodos , Isquemia Miocárdica/diagnóstico por imagen , Isquemia Miocárdica/mortalidad , Imagen de Perfusión Miocárdica/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Algoritmos , Cadmio/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Persona de Mediana Edad , Países Bajos/epidemiología , Variaciones Dependientes del Observador , Prevalencia , Pronóstico , Cintigrafía/instrumentación , Cintigrafía/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Tasa de Supervivencia , Telurio/efectos de la radiación , Zinc/efectos de la radiación
12.
J Nucl Cardiol ; 24(1): 245-251, 2017 02.
Artículo en Inglés | MEDLINE | ID: mdl-27510176

RESUMEN

BACKGROUND: Recent studies have shown that myocardial perfusion imaging (MPI) in cadmium-zinc-telluride (CZT) cameras allow faster exams with less radiation dose but there are little data comparing its prognosis information with that of dedicated cardiac Na-I SPECT cameras OBJECTIVE: The objective of this study is to compare the prognostic value of MPI using an ultrafast protocol with low radiation dose in a CZT-SPECT and a traditional one. METHODS: Group 1 was submitted to a two-day MIBI protocol in a conventional camera, and group 2 was submitted to a 1-day MIBI protocol in CZT camera. MPI were classified as normal or abnormal, and perfusion scores were calculated. Propensity score matching methods were performed RESULTS: 3554 patients were followed during 33±8 months. Groups 1 and 2 had similar distribution of age, gender, body mass index, risk factors, previous revascularization, and use of pharmacological stress. Group 1 had more abnormal scans, higher scores than group 2. Annualized hard events rate was higher in group 1 with normal scans but frequency of revascularization was similar to normal group 2. Patients with abnormal scans had similar event rates in both groups CONCLUSION: New protocol of MPI in CZT-SPECT showed similar prognostic results to those obtained in dedicated cardiac Na-I SPECT camera, with lower prevalence of hard events in patients with normal scan.


Asunto(s)
Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Enfermedad de la Arteria Coronaria/mortalidad , Muerte Súbita Cardíaca/epidemiología , Cámaras gamma/estadística & datos numéricos , Imagen de Perfusión Miocárdica/instrumentación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Brasil/epidemiología , Cadmio/efectos de la radiación , Comorbilidad , Enfermedad de la Arteria Coronaria/cirugía , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Imagen de Perfusión Miocárdica/estadística & datos numéricos , Reproducibilidad de los Resultados , Medición de Riesgo/métodos , Sensibilidad y Especificidad , Tasa de Supervivencia , Telurio/efectos de la radiación , Tomografía Computarizada de Emisión de Fotón Único/estadística & datos numéricos , Resultado del Tratamiento , Zinc/efectos de la radiación
13.
Eur J Nucl Med Mol Imaging ; 43(13): 2423-2432, 2016 12.
Artículo en Inglés | MEDLINE | ID: mdl-27542010

RESUMEN

The trade-off between resolution and count sensitivity dominates the performance of standard gamma cameras and dictates the need for relatively high doses of radioactivity of the used radiopharmaceuticals in order to limit image acquisition duration. The introduction of cadmium-zinc-telluride (CZT)-based cameras may overcome some of the limitations against conventional gamma cameras. CZT cameras used for the evaluation of myocardial perfusion have been shown to have a higher count sensitivity compared to conventional single photon emission computed tomography (SPECT) techniques. CZT image quality is further improved by the development of a dedicated three-dimensional iterative reconstruction algorithm, based on maximum likelihood expectation maximization (MLEM), which corrects for the loss in spatial resolution due to line response function of the collimator. All these innovations significantly reduce imaging time and result in a lower patient's radiation exposure compared with standard SPECT. To guide current and possible future users of the CZT technique for myocardial perfusion imaging, the Cardiovascular Committee of the European Association of Nuclear Medicine, starting from the experience of its members, has decided to examine the current literature regarding procedures and clinical data on CZT cameras. The committee hereby aims 1) to identify the main acquisitions protocols; 2) to evaluate the diagnostic and prognostic value of CZT derived myocardial perfusion, and finally 3) to determine the impact of CZT on radiation exposure.


Asunto(s)
Técnicas de Imagen Cardíaca/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Exposición a la Radiación/análisis , Exposición a la Radiación/prevención & control , Cintigrafía/métodos , Compuestos de Cadmio/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Europa (Continente) , Medicina Basada en la Evidencia , Rayos gamma , Humanos , Dosis de Radiación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Zinc/efectos de la radiación
14.
J Nucl Med ; 57(9): 1370-5, 2016 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-27127220

RESUMEN

UNLABELLED: This study compared two SPECT cameras with cadmium-zinc-telluride (CZT) detectors to a conventional Anger camera with cardiofocal collimators for the assessment of left ventricular (LV) function in a phantom and patients. METHODS: A gated dynamic cardiac phantom was used. Eighteen acquisitions were processed on each CZT camera and the conventional camera. The total number of counts within a myocardial volume of interest varied from 0.25 kcts to 1.5 Mcts. Ejection fraction was set to 33%, 45%, or 60%. Volume, LV ejection fraction (LVEF), regional wall thickening, and motion (17-segment model) were assessed. One hundred twenty patients with a low pretest likelihood of coronary artery disease and normal findings on stress perfusion SPECT were retrospectively analyzed to provide the reference limits for end-diastolic volume (EDV), end-systolic volume (ESV), ejection fraction, and regional function for each camera model. RESULTS: In the phantom study, for each ejection fraction value, volume was higher for the CZT cameras than for the conventional camera, resulting in a decreased but more accurate LVEF (all P < 0.001). In clinical data, body-surface-indexed EDV and ESV (mL/m(2)) were higher for one of the CZT cameras (Discovery NM 530c) than for the other (D-SPECT) or the conventional camera (respectively, 40.5 ± 9.2, 37 ± 7.9, and 35.8 ± 6.8 for EDV [P < 0.001] and 12.5 ± 5.3, 9.4 ± 4.2, and 8.3 ± 4.4 for ESV [P < 0.001]), resulting in a significantly decreased LVEF: 70.3% ± 9.1% vs. 75.2% ± 8.1% vs. 77.8% ± 9.3%, respectively (P < 0.001). CONCLUSION: The new CZT cameras yielded global LV function results different from those yielded by the conventional camera. LV volume was higher for the Discovery NM 530c than for the D-SPECT or the conventional camera, leading to decreased LVEF in healthy subjects. These differences should be considered in clinical practice and warrant the collection of a specific reference database.


Asunto(s)
Cámaras gamma , Volumen Sistólico , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Compuestos de Cadmio/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Transductores , Disfunción Ventricular Izquierda , Compuestos de Zinc/efectos de la radiación
15.
Nucl Med Commun ; 37(6): 650-7, 2016 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-27110956

RESUMEN

OBJECTIVE: Identification of right ventricular (RV) abnormalities is important in patients with suspected coronary artery disease (CAD). RV activity can be better visualized on myocardial single-photon emission computerized tomography (SPECT) using a higher sensitivity cadmium-zinc-telluride (CZT) detector. The aim of this study was to investigate the clinical significance of RV/left ventricular (LV) uptake ratios during exercise thallium-201 SPECT using CZT detectors. PATIENTS AND METHODS: A total of 102 patients underwent treadmill ECG-gated SPECT, coronary angiography, and echocardiography. SPECT myocardial perfusion was interpreted using a 17-segment model and a 0-4-point scale. RV/LV uptake ratios were calculated on the basis of maximum counts per pixel within the entire RV and LV walls. The relationships between RV/LV uptake ratio and gated SPECT, presence of CAD (≥50% stenosis in the left main or ≥70% in the main branches), demographics, and echocardiographic parameters were analyzed. RESULTS: Stress RV/LV ratios correlated positively with the presence of left main or multivessel disease, and tricuspid regurgitation maximum pressure gradient. After multivariate regression, stress/rest RV/LV ratios correlated positively with mitral flow deceleration time, age, female sex, and use of ß-blockers. CONCLUSION: RV/LV uptake ratios on the basis of exercise myocardial perfusion SPECT imaging using CZT cameras are useful for the detection of severe CAD and could serve as an indicator of pulmonary hypertension and LV diastolic dysfunction.


Asunto(s)
Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/instrumentación , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Cámaras gamma , Ventriculografía con Radionúclidos/instrumentación , Radioisótopos de Talio , Disfunción Ventricular Derecha/diagnóstico por imagen , Adulto , Anciano , Anciano de 80 o más Años , Compuestos de Cadmio/efectos de la radiación , Tomografía Computarizada por Emisión de Fotón Único Sincronizada Cardíaca/métodos , Enfermedad de la Arteria Coronaria/complicaciones , Diseño de Equipo , Análisis de Falla de Equipo , Prueba de Esfuerzo/métodos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Ventriculografía con Radionúclidos/métodos , Radiofármacos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Disfunción Ventricular Derecha/etiología , Zinc/efectos de la radiación
16.
Radiat Prot Dosimetry ; 167(1-3): 348-52, 2015 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-25953790

RESUMEN

Instead of conventional Ge semiconductor detectors and NaI(Tl) scintillation spectrometers, an application of a CdZnTe semiconductor (CZT) whose crystal has the dimension of 1 cm cubic to the in situ environmental radioactivity measurement was attempted in deeply affected areas in Fukushima region. Results of deposition density on soil for (134)Cs/(137)Cs obtained seemed consistent, comparing obtained results with those measured by the Japanese government.


Asunto(s)
Cadmio/efectos de la radiación , Radioisótopos de Cesio/análisis , Accidente Nuclear de Fukushima , Monitoreo de Radiación/instrumentación , Ceniza Radiactiva/análisis , Semiconductores , Telurio/efectos de la radiación , Zinc/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Monitoreo de Radiación/métodos , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
17.
Talanta ; 135: 27-33, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25640122

RESUMEN

A new chemiluminescence (CL) flow method for persulfate determination was developed based on luminol oxidation by in-line generated radicals. Reactive oxygen species (ROS) generated by CdTe quantum dots (QDs) under a low energetic radiation (visible light emitted by LEDs) promoted the decomposition of persulfate ion (S2O8(2-)) into sulfate radical (SO4(∙-)), leading to subsequent radical chain reactions that yield the emission of light. Due to the inherent radical short lifetimes and the transient behavior of CL phenomena an automated multi-pumping flow system (MPFS) was proposed to improve sample manipulation and reaction zone implementation ensuring reproducible analysis time and high sampling rate. The developed approach allowed up to 60 determinations per hour and determine S2O8(2-) concentrations between 0.1 and 1 mmol with good linearity (R=0.9999). The method has shown good repeatability with relative standard deviations below 2.5% (n=3) for different persulfate concentrations (0.1 and 0.625 mmol L(-1)). Limits of detection (3σ) and quantification (10σ) were 2.7 and 9.1 µmol L(-1), respectively. The MPFS system was applied to persulfate determination in bench scale UV/S2O8(2-) drug degradation processes of model samples showing good versatility and providing real time information on the persulfate consumption in photo-chemical degradation methodologies.


Asunto(s)
Ácido 3-Mercaptopropiónico/efectos de la radiación , Compuestos de Cadmio/efectos de la radiación , Luminol/química , Compuestos de Potasio/efectos de la radiación , Puntos Cuánticos/efectos de la radiación , Especies Reactivas de Oxígeno/química , Sulfatos/efectos de la radiación , Telurio/efectos de la radiación , Ácido 3-Mercaptopropiónico/química , Compuestos de Cadmio/química , Luz , Nanopartículas/química , Oxidación-Reducción , Compuestos de Potasio/química , Puntos Cuánticos/química , Sulfatos/química , Telurio/química
18.
Adv Mater ; 26(36): 6313-7, 2014 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-25066411

RESUMEN

Lattice-strained CdTe/CdS:Cu quantum dots (QDs) with a widely tunable near-infrared (NIR) fluorescence emission spectrum (700-910 nm) and long lifetime (up to 1 µs) are synthesized. Based on the multiemission and multi-lifetime of the well-defined QDs, NIR-emitting two-dimensional (2D) codes are achieved by embedding as-prepared QDs into agarose beads. This provides a new strategy for fluorescent 2D codes.


Asunto(s)
Compuestos de Cadmio/química , Puntos Cuánticos , Espectroscopía Infrarroja Corta/métodos , Sulfuros/química , Telurio/química , Compuestos de Cadmio/efectos de la radiación , Luz , Ensayo de Materiales , Sulfuros/efectos de la radiación , Telurio/efectos de la radiación
19.
J Nucl Cardiol ; 21(6): 1158-67, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25005346

RESUMEN

BACKGROUND: Guidelines for SPECT myocardial perfusion imaging (MPI) traditionally recommend a fixed tracer dose. Yet, clinical practice shows degraded image quality in heavier patients. The aim was to optimize and validate the tracer dose and scan time to obtain a constant image quality less dependent on patients' physical characteristics. METHODS: 125 patients underwent Cadmium Zinc Telluride (CZT)-SPECT stress MPI using a fixed Tc-99m-tetrofosmin tracer dose. Image quality was scored by three physicians on a 4-point grading scale and related to the number of photon counts normalized to tracer dose and scan time. Counts were correlated with various patient-specific parameters dealing with patient size and weight to find the best predicting parameter. From these data, a formula to provide constant image quality was derived, and subsequently tested in 92 new patients. RESULTS: Degradation in image quality and photon counts was observed for heavier patients for all patients' specific parameters (P < .01). We found body weight to be the best-predicting parameter for image quality and derived a new dose formula. After applying this new body weight-depended tracer dose and scan time in a new group, image quality was found to be constant (P > .19) in all patients. CONCLUSIONS: Also in CZT SPECT image quality decreases with weight. The use of a tracer dose and scan time that depends linearly on patient's body weight corrected for the varying image quality in CZT-SPECT MPI. This leads to better radiation exposure justification.


Asunto(s)
Tamaño Corporal , Dosis Máxima Tolerada , Imagen de Perfusión Miocárdica/métodos , Compuestos Organofosforados/administración & dosificación , Compuestos de Organotecnecio/administración & dosificación , Tomografía Computarizada de Emisión de Fotón Único/métodos , Cadmio/efectos de la radiación , Femenino , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Masculino , Persona de Mediana Edad , Variaciones Dependientes del Observador , Seguridad del Paciente , Dosis de Radiación , Protección Radiológica/métodos , Radiofármacos/administración & dosificación , Reproducibilidad de los Resultados , Sensibilidad y Especificidad , Telurio/efectos de la radiación , Recuento Corporal Total/métodos , Zinc/efectos de la radiación
20.
J Nucl Cardiol ; 21(3): 443-52, 2014 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-24429938

RESUMEN

BACKGROUND: A solid-state cadmium zinc telluride (CZT) SPECT device provides ultrafast myocardial perfusion imaging (MPI) with a spherical field-of-view (FOV). This study aims at determining the spatial resolution and sensitivity throughout this FOV as a guide for patient positioning. METHODS AND RESULTS: For this CZT camera (Discovery 570c, GE Healthcare), the iteratively reconstructed spatial resolution along 3 Cartesian axes was compared (average resolution 6.9 ± 1.0 mm full-width at half-maximum) using a 2 dimensional array of point sources in air which was aligned with a transverse plane shifted throughout the FOV. Sensitivity was plotted in the central transverse slice and axially in locations comparable to the placement of the heart in 266 rest/stress cardiac studies (M 78, age 63 ± 13 years). The average sensitivity was 0.46 ± 0.19 kc/s/MBq with a transverse gradient of 0.039 ± 0.001 kc/s/MBq/cm (8.9% of the sensitivity per cm). Reconstructed relative activity was uniform (uniformity <9%) and count rate was linear (R = 0.999) over 3 orders of magnitude. CONCLUSIONS: The CZT SPECT camera offers good resolution, sensitivity, and uniformity, and provides linearity in count rate. A gradient of >8%/cm in sensitivity justifies the crucial role of patient positioning with the heart closest to the detector.


Asunto(s)
Algoritmos , Cadmio/efectos de la radiación , Interpretación de Imagen Asistida por Computador/instrumentación , Imagenología Tridimensional/instrumentación , Imagen de Perfusión Miocárdica/instrumentación , Reconocimiento de Normas Patrones Automatizadas/métodos , Telurio/efectos de la radiación , Tomografía Computarizada de Emisión de Fotón Único/instrumentación , Zinc/efectos de la radiación , Diseño de Equipo , Análisis de Falla de Equipo , Humanos , Aumento de la Imagen/métodos , Fantasmas de Imagen , Reproducibilidad de los Resultados , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA