Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.203
Filtrar
1.
Zhongguo Gu Shang ; 36(9): 809-14, 2023 Sep 25.
Artículo en Chino | MEDLINE | ID: mdl-37735070

RESUMEN

Objective To explore the short-term efficacy of digitally-assisted traditional Chinese medicine manual reduction combined with 3D printed splint in the treatment of AO type-A distal radius fractures, and explore the quantification of traditional Chinese medicine manual reduction and personalized improvement of splinting. Methods The clinical data of 50 patients with AO type-A distal radius fractures, who received treatment at the outpatient department of Cangzhou Integrated Traditional Chinese and Western Medicine Hospital in Hebei Province, were retrospective analyzed. The patient cohort included 22 females and 28 males, with ages ranging from 25 to 75 years old. Among them, 27 cases presented with distal radius fractures on the left side, and 24 cases on the right side. The patients were categorized into two groups: treatment group (n=25) and control group(n=25). There were 13 males and 12 females in the treatment group, with an average age of (56.2±5.5) years old. Treatment approach for this group involved several steps. Initially, Mimics Research software was used to conduct comprehensive analysis of complete CT data from the affected limb, resulting in the creation of a three-dimensional model. Subsequently, 3D models of the bones and skin contours, stored as STL format files, were imported into the Materialise Magics 23.0 software for model processing and repair. This facilitated the simulation of reduction and recording of displacement data, effectively generating a "digital prescription" to guide and quantify traditional Chinese medicine manipulation procedures. Finally, a personalized 3D printed splint was applied for fixation treatment. There were 15 males and 10 females in the control group, with an average age of (53.32±5.28) years old. These patients were treated with manualreduction combined with traditional splinting. The clinical efficacy of the two groups was assessed in terms of fracture reduction quality, fracture healing time, Gartland-Werley wrist joint score and X-ray parameters (palminclination angle, ulnar deviation angle, radius height) at 6 weeks post-operatively. Results The treatment group exhibited a shorter duration for achieving clinical healing compared to the control group (P<0.05). Six weeks post-operatively, the treatment group demonstrated higher wrist joint function scores, and a higher proportion of excellent and good outcomes than the control group(P<0.05). The treatment group was superior to the control group in terms of imaging parameters 6 weeks post-operatively (P<0.05). Conclusion By quantifying skin contours through digital simulation prescription reduction, a personalized 3D printed splint is developed to effectively stabilize fractures, enhancing localized fixation while ensuring greater adherence, stability, and comfort. This innovative approach offers personalized treatment for AO type-A distal radius fractures and presents a novel, precise treatment strategy for consideration.


Asunto(s)
Manipulación Ortopédica , Medicina Tradicional China , Impresión Tridimensional , Férulas (Fijadores) , Terapia Asistida por Computador , Fracturas de la Muñeca , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pueblos del Este de Asia , Estudios Retrospectivos , Fracturas de la Muñeca/diagnóstico por imagen , Fracturas de la Muñeca/cirugía , Fracturas de la Muñeca/terapia , Medicina Tradicional China/métodos , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/métodos , Manipulación Ortopédica/métodos , Tomografía Computarizada por Rayos X , Medicina de Precisión/instrumentación , Medicina de Precisión/métodos
3.
Ann Vasc Surg ; 71: 273-279, 2021 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-32890647

RESUMEN

BACKGROUND: Fusion imaging makes it possible to improve endovascular procedures and is mainly used in hybrid rooms for aortic procedures. The objective of this study was to evaluate the feasibility of fusion imaging for femoropopliteal endovascular procedures with a mobile flat plane sensor and dedicated software to assist endovascular navigation. MATERIALS AND METHODS: Between May and December 2017, 41 patients requiring femoropopliteal endovascular revascularization were included. Interventions were carried out in a conventional surgical room equipped with a mobile plane sensor (Cios Alpha, Siemens). The numerical video stream was transmitted to an angionavigation station (EndoNaut (EN), Therenva). The software created an osseous and arterial panorama of the treated limb from the angiographies carried out at the beginning of procedure. After each displacement of the table, the software relocated the current image on the osseous panorama, with 2D-2D resetting, and amalgamated the mask of the arterial panorama. The success rates of creation of osseous and arterial panorama and the success of relocation were evaluated. The data concerning irradiation, the volume of contrast (VC) injected, and operative times were recorded. RESULTS: Osseous panoramas could be automatically generated for the 41 procedures, without manual adjustment in 33 cases (80.5%). About 35 relocations based on a 2D-2D resetting could be obtained in the 41 procedures, with a success rate of 85%. The causes of failure were a change in table height or arch angulation. The average duration of intervention was 74.5 min. The irradiation parameters were duration of fluoroscopy 17.8 ± 13.1 min, air kerma 80.5 ± 68.4 mGy, and dose area product 2140 ± 1599 µGy m2. The average VC was 24.5 ± 14 mL. CONCLUSIONS: This preliminary study showed that fusion imaging is possible in a nonhybrid room for peripheral procedures. Imagery of mobile C-arms can be improved for femoropopliteal endovascular procedures without heavy equipment. These imagery tools bring an operative comfort and could probably reduce irradiation and the injected VC. The clinical benefit must be evaluated in more patients in a randomized comparative study with a rigorous methodology.


Asunto(s)
Angiografía/instrumentación , Procedimientos Endovasculares/instrumentación , Arteria Femoral/diagnóstico por imagen , Enfermedad Arterial Periférica/diagnóstico por imagen , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/diagnóstico por imagen , Interpretación de Imagen Radiográfica Asistida por Computador , Radiografía Intervencional/instrumentación , Terapia Asistida por Computador/instrumentación , Anciano , Anciano de 80 o más Años , Procedimientos Endovasculares/efectos adversos , Estudios de Factibilidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Quirófanos , Proyectos Piloto , Valor Predictivo de las Pruebas , Estudios Prospectivos , Radiografía Intervencional/efectos adversos , Programas Informáticos , Factores de Tiempo , Resultado del Tratamiento
4.
Neurorehabil Neural Repair ; 34(12): 1150-1158, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33084499

RESUMEN

BACKGROUND: Studies examining the effects of therapeutic interventions after stroke often focus on changes in loss of body function/structure (impairment). However, improvements in activities limitations and participation restriction are often higher patient priorities, and the relationship that these measures have with loss of body function/structure is unclear. OBJECTIVE: This study measured gains across WHO International Classification of Function (ICF) dimensions and examined their interrelationships. METHODS: Subjects were recruited 11 to 26 weeks after hemiparetic stroke. Over a 3-week period, subjects received 12 sessions of intensive robot-based therapy targeting the distal arm. Each subject was assessed at baseline and at 1 month after end of therapy. RESULTS: At baseline, subjects (n = 40) were 134.7 ± 32.4 (mean ± SD) days poststroke and had moderate-severe arm motor deficits (arm motor Fugl-Meyer score of 35.6 ± 14.4) that were stable. Subjects averaged 2579 thumb movements and 1298 wrist movements per treatment session. After robot therapy, there was significant improvement in measures of body function/structure (Fugl-Meyer score) and activity limitations (Action Research Arm Test, Barthel Index, and Stroke Impact Scale-Hand), but not participation restriction (Stroke Specific Quality of Life Scale). Furthermore, while the degree of improvement in loss of body function/structure was correlated with improvement in activity limitations, neither improvement in loss of body function/structure nor improvement in activity limitations was correlated with change in participation restriction. CONCLUSIONS: After a 3-week course of robotic therapy, there was improvement in body function/structure and activity limitations but no reduction in participation restriction.


Asunto(s)
Evaluación de Resultado en la Atención de Salud , Paresia/rehabilitación , Recuperación de la Función/fisiología , Índice de Severidad de la Enfermedad , Rehabilitación de Accidente Cerebrovascular , Accidente Cerebrovascular/terapia , Terapia Asistida por Computador , Adulto , Anciano , Femenino , Humanos , Estudios Longitudinales , Masculino , Persona de Mediana Edad , Paresia/etiología , Robótica , Accidente Cerebrovascular/complicaciones , Rehabilitación de Accidente Cerebrovascular/instrumentación , Rehabilitación de Accidente Cerebrovascular/métodos , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/métodos , Organización Mundial de la Salud
5.
J Healthc Eng ; 2020: 7963497, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32850104

RESUMEN

Robotic intravenous poles are automated supportive instrument that needs to be triggered by patients to hold medications and needed supplies. Healthcare engineering of robotic intravenous poles is advancing in order to improve the quality of health services to patients worldwide. Existing intravenous poles in the market were supportive to patients, yet they constrained their movement, consumed the time of both the patient and the nurse, and they were expensive in regard to what they offer. Although robotic poles overcame some of the movement limitations of the commercial/market poles, they were partially automated and did not offer additional technological features. The aim of our work was to develop a fully automated Biomedical Intravenous Pole Robot (BMIVPOT) to resolve the aforementioned limitations and to offer new technological features to intravenous poles, thereby promoting the health services. Several sensors and build-up materials were empirically chosen to be cost-effective and fulfill our needs. The new prototype was divided into three steps: simulated prototype, real implementation of the prototype, and testing and evaluation. Simulation results showed the best qualitative way to fit all the specifications in the robotic system, such as the shape, sensors, and connections in order to provide the proper functionality of the system. Experimental and real results provided the manufactured parts, implemented sensors, and the final robot. Testing the tracking and the flow sensor performances were provided. Evaluation of our Biomedical Intravenous Pole Robot with alternatives showed that our robot outperforms the other poles in many aspects including the features it offers, the percentage of interventions it comprised, the reliability, and cost-effectiveness. The overall percentage of features offered by our Biomedical Intravenous Pole Robot was 60% higher than that offered by peer research poles and 80% higher than that of the market poles. In addition, the average percentage of integration of interventions (architecture, sensor, wireless, tracking, and mechanical) in the Biomedical Intravenous Pole Robot was at least 56% higher than that of the alternative poles. According to the results, Biomedical Intravenous Pole Robot offers a cost-effective price as compared to the others. As a future prospect, we intend to add more features to this prototype in order to enhance it, such as vital signs detection, and improve the tracking system.


Asunto(s)
Infusiones Intravenosas/instrumentación , Robótica , Terapia Asistida por Computador/instrumentación , Inteligencia Artificial , Automatización , Simulación por Computador , Diseño Asistido por Computadora , Análisis Costo-Beneficio , Diseño de Equipo , Equipos y Suministros de Hospitales , Humanos , Procesamiento de Imagen Asistido por Computador , Microcomputadores , Aplicaciones Móviles , Seguridad del Paciente , Reproducibilidad de los Resultados , Integración de Sistemas , Interfaz Usuario-Computador
6.
J Cardiovasc Electrophysiol ; 31(4): 825-833, 2020 04.
Artículo en Inglés | MEDLINE | ID: mdl-32009263

RESUMEN

BACKGROUND: The AdaptivCRT (aCRT) algorithm continuously adjusts cardiac resynchronization therapy (CRT) according to intrinsic atrioventricular conduction, providing synchronized left ventricular pacing in patients with normal PR interval and adaptive BiV pacing in patients with prolonged PR interval. Previous analyses demonstrated an association between aCRT and clinical benefit. We evaluated the incidence of patient mortality and atrial fibrillation (AF) with aCRT compared with standard CRT in a real-world population. METHODS AND RESULTS: Patients enrolled in the Medtronic Personalized CRT Registry and implanted with a CRT from 2013-2018 were divided into aCRT ON or standard CRT groups based upon device-stored data. A Frailty survival model was used to evaluate the potential survival benefit of aCRT, accounting for patient heterogeneity and center variability. Daily AF burden and first device-detected AF episodes of various durations were recorded by the device during follow-up. A total of 1814 CRT patients with no reported long-standing AF history at implant were included. Mean follow-up time was 26.1 ± 16.5 months and 1162 patients (64.1%) had aCRT ON. Patient survival probability at 36 months was 88.3% for aCRT ON and 83.7% for standard CRT (covariate-adjusted hazard ratio [HR] = 0.71, 95% CI: 0.53-0.96, P = .028). Mean AF burden during follow-up was consistently lower in aCRT ON patients compared with standard CRT. At 36 months, the probability of AF was lower in patients with aCRT ON, regardless of which AF definition threshold was applied (6 minutes-30 days, all P < .001). CONCLUSION: Use of the AdaptivCRT algorithm was associated with improved patient survival and lower incidence of AF in a real-world, prospective, nonrandomized registry.


Asunto(s)
Algoritmos , Fibrilación Atrial/epidemiología , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca/efectos adversos , Insuficiencia Cardíaca/terapia , Terapia Asistida por Computador/instrumentación , Anciano , Fibrilación Atrial/diagnóstico , Fibrilación Atrial/mortalidad , Terapia de Resincronización Cardíaca/mortalidad , Femenino , Insuficiencia Cardíaca/diagnóstico , Insuficiencia Cardíaca/mortalidad , Insuficiencia Cardíaca/fisiopatología , Humanos , Incidencia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Sistema de Registros , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
7.
Catheter Cardiovasc Interv ; 95(5): 920-923, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31250510

RESUMEN

A 34-year-old woman with history of surgical correction (Takeuchi procedure) of anomalous left coronary artery from the pulmonary artery (ALCAPA) presented with reduced left ventricular ejection fraction of 48% and severe ischemia quantified as 21% by stress Positron Emission Tomography (PET) scan. A coronary angiogram revealed ostial 90% stenosis of the left main coronary artery (LMCA). A guidewire (Sion Blue, Asahi Intecc USA, Inc., Santa Ana, CA) was navigated robotically and after pre-dilation with 3.5 × 15 mm cutting balloon, the lesion length was measured by marking the distal end of the lesion with the balloon marker and withdrawing back robotically to the ostium of the LMCA. A 3.5 × 16 mm drug-eluting stent was deployed robotically after intravascular ultrasound (IVUS) with good results. The main advantage of robotic percutaneous coronary intervention includes the precise measurement and positioning of the stent. Since the guide catheter and balloon can be adjusted without guide catheter and device interaction, precise placement of stent is possible by advancing the device distal to the lesion, positioning the guide catheter just proximal to the proximal edge of the stent and pulling the guidecatheter and device back as a unit. Final IVUS after post-dilation with 4.0 noncompliant and 5.0 compliant balloon revealed precise placement at the ostium and full stent expansion.


Asunto(s)
Angioplastia Coronaria con Balón , Síndrome de Bland White Garland/cirugía , Procedimientos Quirúrgicos Cardíacos/efectos adversos , Estenosis Coronaria/terapia , Vasos Coronarios/cirugía , Arteria Pulmonar/cirugía , Robótica , Terapia Asistida por Computador , Adulto , Angioplastia Coronaria con Balón/instrumentación , Síndrome de Bland White Garland/diagnóstico por imagen , Síndrome de Bland White Garland/fisiopatología , Estenosis Coronaria/diagnóstico por imagen , Estenosis Coronaria/etiología , Estenosis Coronaria/fisiopatología , Vasos Coronarios/diagnóstico por imagen , Vasos Coronarios/fisiopatología , Stents Liberadores de Fármacos , Femenino , Humanos , Arteria Pulmonar/anomalías , Arteria Pulmonar/diagnóstico por imagen , Arteria Pulmonar/fisiopatología , Terapia Asistida por Computador/instrumentación , Resultado del Tratamiento
8.
J Cardiovasc Comput Tomogr ; 14(2): 149-154, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-31445885

RESUMEN

BACKGROUND: Percutaneous left atrial appendage (LAA) closure can be optimised through diligent preprocedural planning. Cardiac computational tomography (CCT) is increasingly recognised as a valuable tool in this process. A CCT-based computational model (FEops HEARTguide™, Belgium) has been developed to simulate the deployment of the two most commonly used LAA closure devices into patient-specific LAA anatomies. OBJECTIVE: The aim of this study was to validate this computational model based on real-life percutaneous LAA closure procedures and post-procedural CCT imaging. METHODS: Thirty patients having undergone LAA closure (Amulet™ n = 15, Watchman™ n = 15) and having a pre- and post-procedural CCT-scan were selected for this validation study. Virtually implanted devices were directly compared to actual implants for device frame deformation and LAA wall apposition. RESULTS: The coefficient of determination (R2) and the difference in measurements between model and actual device (area, perimeter, minimum diameter, maximum diameter) were ≥0.91 and ≤ 5%, respectively. For both device types, the correlation coefficient between predicted and observed measurements was higher than 0.90. Furthermore, predicted device apposition correlated well with observed leaks based on post-procedural CCT. CONCLUSION: Computational modelling accurately predicts LAA closure device deformation and apposition and may therefore potentiate more accurate LAA closure device sizing and better preprocedural planning.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco , Modelación Específica para el Paciente , Terapia Asistida por Computador , Tomografía Computarizada por Rayos X , Anciano , Anciano de 80 o más Años , Apéndice Atrial/fisiopatología , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/fisiopatología , Colombia Británica , Cateterismo Cardíaco/efectos adversos , Cateterismo Cardíaco/instrumentación , Dinamarca , Diseño de Equipo , Femenino , Humanos , Masculino , Persona de Mediana Edad , Modelos Cardiovasculares , Paris , Valor Predictivo de las Pruebas , Reproducibilidad de los Resultados , Estudios Retrospectivos , Terapia Asistida por Computador/instrumentación , Resultado del Tratamiento
9.
Catheter Cardiovasc Interv ; 95(5): 914-919, 2020 04 01.
Artículo en Inglés | MEDLINE | ID: mdl-31410958

RESUMEN

OBJECTIVE: This study evaluated the impact of network latency on telestenting performance. BACKGROUND: The feasibility of long-distance robotic telestenting was recently demonstrated, yet the impact of network performance on telestenting remains unknown. METHODS: Ex vivo and in vivo telestenting models were constructed by connecting a robotic drive over a wired network to a robotic control system up to 103 miles away. During consecutive attempts to robotically wire a coronary artery, investigators randomly added signal latencies from 0 to 1,000 ms. Outcomes included wiring success, wiring time (time to advance wire to preselected target landmark), and perceived latency score (5 = imperceptible; 4 = noticeable but minor; 3 = noticeable; 2 = noticeable and major; 1 = unacceptable). RESULTS: Wiring success was achieved in 95 of 95 attempts in the ex vivo model and in 57 of 57 attempts in vivo. No significant difference in wiring time was observed across added latencies from 0 to 1,000 ms in the ex vivo (p = .64) or in vivo (p = .40) models. Compared to an added latency of 0 ms, perceived latency scores were not significantly different for added latencies of 150 and 250 ms (p = NS for both), but were significantly lower for latencies ≥400 ms (p < .001). CONCLUSIONS: Added latencies up to 250 ms were not associated with perceived latency, but latencies ≥400 ms were perceptible. Based on these findings, future telestenting studies should utilize networks with latencies ≤250 ms if perceived latency is to be avoided.


Asunto(s)
Redes de Comunicación de Computadores , Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/instrumentación , Consulta Remota/instrumentación , Robótica/instrumentación , Stents , Terapia Asistida por Computador/instrumentación , Animales , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Estudios de Factibilidad , Femenino , Humanos , Maniquíes , Modelos Animales , Intervención Coronaria Percutánea/efectos adversos , Sus scrofa , Factores de Tiempo
10.
Catheter Cardiovasc Interv ; 95(1): 165-169, 2020 01.
Artículo en Inglés | MEDLINE | ID: mdl-31483078

RESUMEN

BACKGROUND: No previous reports have examined the impact of robotic-assisted (RA) chronic total occlusion (CTO) PCI on procedural duration or safety compared to totally manual CTO PCI. METHODS: Among 95 patients who underwent successful PCI of a single CTO lesion at two centers, 49 (52%) were performed RA and were performed 46 (48%) totally manually. Cockpit time was the time the primary operator entered to robotic cockpit until the procedure was complete. "Theoretical" cockpit time in the control group was time the primary operator would have entered the cockpit after lesion crossing until the procedure was complete. Major adverse events (MAEs) were the composite of death, myocardial infarction, clinical perforation, significant vessel dissection, arrhythmia, acute thrombosis, and stroke. RESULTS: The lesion characteristics, procedural time, and contrast dose were similar. All procedures except for one (2%) selected for robotic completion after lesion crossing were completed successfully. The frequency of MAE was similar between groups and there were no in-hospital deaths. The cockpit time was 8 min longer in RA CTO PCI than the theoretical cockpit time in totally manual CTO PCI (40.6 ± 12.7 vs. 32.1 ± 17.8, p < .01). CONCLUSION: RA CTO PCI was not associated with excess adverse events compared with totally manual CTO PCI and resulted in an average 41 min cockpit time equaling to 48% of procedure time without radiation exposure or requirement for the primary operator to wear a lead apron. Understanding the relationship between cockpit time and reductions in radiation exposure and lead apron-related orthopedic complications for operators requires future study.


Asunto(s)
Angioplastia Coronaria con Balón , Oclusión Coronaria/terapia , Robótica , Terapia Asistida por Computador , Anciano , Angioplastia Coronaria con Balón/efectos adversos , Angioplastia Coronaria con Balón/instrumentación , Angioplastia Coronaria con Balón/mortalidad , Oclusión Coronaria/diagnóstico por imagen , Oclusión Coronaria/mortalidad , Oclusión Coronaria/fisiopatología , Femenino , Humanos , Masculino , Persona de Mediana Edad , Missouri , Seguridad del Paciente , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Robótica/instrumentación , Stents , Terapia Asistida por Computador/instrumentación , Factores de Tiempo , Resultado del Tratamiento , Washingtón
12.
Trials ; 20(1): 712, 2019 Dec 11.
Artículo en Inglés | MEDLINE | ID: mdl-31829286

RESUMEN

BACKGROUND: Active self-management is a process where patients are fully engaged in managing their health in daily life by having access to contextualized health data and tailored guidance to support a healthy lifestyle. This study aims to determine whether an e-health intervention that incorporates symptom/disease activity monitoring and physical activity counselling can improve self-management ability in patients with rheumatoid arthritis (RA). METHODS: The 'Empowering active self-management of arthritis: Raising the bar with OPERAS (an On-demand Program to EmpoweR Active Self-management)' project is a randomized controlled trial that uses a delayed control design. One hundred thirty-four participants with RA will be randomly assigned to start the intervention either immediately (immediate group) or 6 months later (delayed group). The intervention involves (1) use of a Fitbit-compatible web app to record and monitor their RA disease activity, symptoms, and time spent on physical activity and a Fitbit; (2) group education and individual counselling by a physiotherapist (PT); and (3) six phone calls with a PT. The primary outcome measure is self-management ability measured by the Patient Activation Measure. Secondary outcome measures include disease status, fatigue, pain, depressive symptoms, and characteristics of habitual behavior and also time spent in physical activity and sedentary activity with a wearable multi-sensor device (SenseWear Mini). After the 6-month intervention, we will interview a sample of participants to examine their experiences with the intervention. DISCUSSION: The results of this study will help to determine whether this technology-enhanced self-management intervention improves self-management ability and health outcomes for people living with RA. A limitation of this study is that participants will need to self-report their symptoms, disease status, and treatment use through questionnaires on the OPERAS web app. The user-friendly interface, reminder emails from the research staff, and tailored guidance from PTs will encourage participants to actively engage with the app. TRIAL REGISTRATION: Date of last update in ClinicalTrials.gov: January 2, 2019. ClinicalTrials.gov Identifier: NCT03404245.


Asunto(s)
Actigrafía , Artritis Reumatoide/terapia , Intervención basada en la Internet , Participación del Paciente , Autocuidado , Telemedicina , Terapia Asistida por Computador , Actigrafía/instrumentación , Artritis Reumatoide/diagnóstico , Artritis Reumatoide/fisiopatología , Artritis Reumatoide/psicología , Colombia Británica , Consejo , Ejercicio Físico , Monitores de Ejercicio , Procesos de Grupo , Estado de Salud , Humanos , Educación del Paciente como Asunto , Ensayos Clínicos Controlados Aleatorios como Asunto , Autocuidado/instrumentación , Telemedicina/instrumentación , Terapia Asistida por Computador/instrumentación , Factores de Tiempo , Resultado del Tratamiento
14.
J Autism Dev Disord ; 49(12): 5047-5062, 2019 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-31512152

RESUMEN

Individuals with autism spectrum disorders (ASD) often present with difficulty in sustaining engagement, attention, and have disruptive behavior in classroom settings. Without appropriate intervention, these challenging behaviors often persist and negatively impact educational outcomes. Self-monitoring is a well-supported evidence-based practice for addressing challenging behaviors and improving pro-social behaviors for individuals with ASD. Self-monitoring procedures utilizing a handheld computer-based technology is an unobtrusive and innovative way of implementing the intervention. A withdrawal design was employed to assess the effectiveness of a technologically-delivered self-monitoring intervention (I-Connect) in improving on-task and task completion behaviors and decreasing disruptive behavior with four adolescents with ASD. Results demonstrated improvements in on-task and task completion behaviors across all four participants and disruptive behavior improved for two participants.


Asunto(s)
Trastorno Autístico/rehabilitación , Terapia Conductista/métodos , Computadoras de Mano , Terapia Asistida por Computador/métodos , Adolescente , Terapia Conductista/instrumentación , Femenino , Humanos , Masculino , Problema de Conducta , Conducta Social , Terapia Asistida por Computador/instrumentación
15.
Curr Cardiol Rep ; 21(10): 119, 2019 08 31.
Artículo en Inglés | MEDLINE | ID: mdl-31473815

RESUMEN

PURPOSE OF REVIEW: To review the contemporary evidence for robotic-assisted percutaneous coronary and vascular interventions, discussing its current capabilities, limitations, and potential future applications. RECENT FINDINGS: Robotic-assisted cardiovascular interventions significantly reduce radiation exposure and orthopedic strains for interventionalists, while maintaining high rates of device and clinical success. The PRECISE and CORA-PCI studies demonstrated the safety and efficacy of robotic-assisted percutaneous coronary intervention (PCI) in increasingly complex coronary lesions. The RAPID study demonstrated similar findings in peripheral vascular interventions (PVI). Subsequent studies have demonstrated the safety and efficacy of second-generation devices, with automations mimicking manual PCI techniques. While innovations such as telestenting continue to bring excitement to the field, major limitations remain-particularly the lack of randomized trials comparing robotic-assisted PCI with manual PCI. Robotic technology has successfully been applied to multiple cardiovascular procedures. There are limited data to evaluate outcomes with robotic-assisted PCI and other robotic-assisted cardiovascular procedures, but existing data show some promise of improving the precision of PCI while decreasing occupational hazards associated with radiation exposure.


Asunto(s)
Enfermedad de la Arteria Coronaria/terapia , Intervención Coronaria Percutánea/métodos , Robótica/métodos , Terapia Asistida por Computador/instrumentación , Cardiología/tendencias , Angiografía Coronaria , Enfermedad de la Arteria Coronaria/diagnóstico por imagen , Humanos , Exposición a la Radiación , Traumatismos por Radiación/prevención & control , Resultado del Tratamiento
16.
NeuroRehabilitation ; 45(2): 285-290, 2019.
Artículo en Inglés | MEDLINE | ID: mdl-31498141

RESUMEN

BACKGROUND: Parkinson's disease (PD) is a neurodegenerative disease due to dopamine deficiency in the basal ganglia, leading to motor symptoms such as bradykinesia, tremor, stiffness, and postural instability. This disease may also be associated with a broad spectrum of non-motor symptoms. More than 24% of patients with PD have one or more cognitive symptoms. OBJECTIVE: To evaluate the effects of computer-assisted cognitive rehabilitation (CACR) in Parkinson's disease (PD). METHODS: Sixty patients with PD were enrolled in this study and were randomly divided into control group (CG) and experimental group (EG). Each participant was evaluated at the beginning (T0) and at the end of training (T1). The CG underwent standard cognitive training (SCT) while EG performed CACR using the ERICA platform, aimed at improving several cognitive domains. In both the group, each training consisted of 3 sessions a week, each of these lasting sixty minutes, for eight weeks. RESULTS: Although both the groups had significant improvement after CR, we observed more significant changes in the EG, especially concerning attention, orientation and visual-spatial domains. CONCLUSIONS: Our data demonstrate that CACR is more effective than SCT in improving visual-spatial and executive deficits, in patients affected by PD.


Asunto(s)
Cognición , Función Ejecutiva , Rehabilitación Neurológica/métodos , Enfermedad de Parkinson/rehabilitación , Conducta Espacial , Terapia Asistida por Computador/métodos , Atención , Femenino , Humanos , Masculino , Persona de Mediana Edad , Rehabilitación Neurológica/instrumentación , Terapia Asistida por Computador/instrumentación
17.
Circ J ; 83(10): 2002-2009, 2019 09 25.
Artículo en Inglés | MEDLINE | ID: mdl-31462585

RESUMEN

BACKGROUND: An adaptive cardiac resynchronization therapy (aCRT) algorithm has been described for synchronized left ventricular (LV) pacing and continuous optimization of cardiac resynchronization therapy (CRT). However, there are few algorithmic data on the effect of changes during exercise.Methods and Results:We enrolled 27 patients with availability of the aCRT algorithm. Eligible patients were manually programmed to optimal atrioventricular (AV) and interventricular (VV) delays by using echocardiograms at rest or during 2 stages of supine bicycle exercise. We compared the maximum cardiac output between manual echo-optimization and aCRT-on during each phase. After initiating exercise, the optimal AV delay progressively shortened (P<0.05) with incremental exercise levels. The manual-optimized settings and aCRT resulted in similar cardiac performance, as demonstrated by a high concordance correlation coefficient between the LV outflow tract velocity time integral (LVOT-VTI) during each exercise stage (Ex.1: r=0.94 P<0.0008, Ex.2: r=0.88 P<0.001, respectively). Synchronized LV-only pacing in patients with normal AV conduction could provide a higher LVOT-VTI as compared with manual-optimized conventional biventricular pacing at peak exercise (P<0.05). CONCLUSIONS: The aCRT algorithm was physiologically sound during exercise by patients.


Asunto(s)
Algoritmos , Dispositivos de Terapia de Resincronización Cardíaca , Terapia de Resincronización Cardíaca , Tolerancia al Ejercicio , Insuficiencia Cardíaca/terapia , Hemodinámica , Procesamiento de Señales Asistido por Computador , Terapia Asistida por Computador/instrumentación , Función Ventricular Izquierda , Adaptación Fisiológica , Anciano , Anciano de 80 o más Años , Ecocardiografía Doppler de Pulso , Ecocardiografía de Estrés , Prueba de Esfuerzo , Femenino , Insuficiencia Cardíaca/diagnóstico por imagen , Insuficiencia Cardíaca/fisiopatología , Frecuencia Cardíaca , Humanos , Masculino , Persona de Mediana Edad , Volumen Sistólico , Factores de Tiempo , Resultado del Tratamiento
18.
Int J Cardiovasc Imaging ; 35(9): 1721-1731, 2019 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-31250161

RESUMEN

To compare planned and achieved device position in patients undergoing left atrial appendage occlusion (LAAO). It is unclear how devices used for LAAO position themselves compared to what is planned. All patients undergoing LAAO at our institution had pre- and post-procedural multi detector-row computed tomography (MDCT) at 3 months (N = 52). Using dedicated software, both datasets were fused to superimpose the left atria in all planes. The effective device position was traced on the post-procedural MDCT and then imported in the pre-procedural dataset to allow comparisons. Planned and effective landing zones were compared with respect to size, location and orientation. The device's final position was in a significantly larger landing zone than planned (452 ± 174 vs. 351 ± 112 mm2 for effective and planned landing zones, respectively, paired t-test: p < 0.0001), resulting in significantly less-than-intended area oversizing (41 ± 31 vs. 12 ± 28%, p < 0.0001). In terms of device orientation, there was a difference of 19.7° between the planned and effective landing zones (p < 0.0001). The Amplatzer device had a shallower-than-planned position in 70% of cases, whereas the Watchman device had a deeper-than-planned position in 75% of cases (p = 0.04). Incomplete occlusion was found in 17 patients (33%). In a multivariable model, oversizing at the effective landing zone was the only MDCT independent predictor of incomplete occlusion (OR: 0.96 per 1% increment, 95% CI 0.95-0.98, p = 0.009). MDCT fusion showed that LAAO device position and orientation are different than planned, and this is associated with incomplete occlusion of the LAA.


Asunto(s)
Apéndice Atrial/diagnóstico por imagen , Fibrilación Atrial/diagnóstico por imagen , Fibrilación Atrial/terapia , Cateterismo Cardíaco/instrumentación , Imagenología Tridimensional/métodos , Tomografía Computarizada Multidetector/métodos , Interpretación de Imagen Radiográfica Asistida por Computador/métodos , Terapia Asistida por Computador/instrumentación , Anciano , Anciano de 80 o más Años , Apéndice Atrial/fisiopatología , Fibrilación Atrial/fisiopatología , Función del Atrio Izquierdo , Cateterismo Cardíaco/efectos adversos , Toma de Decisiones Clínicas , Femenino , Humanos , Masculino , Valor Predictivo de las Pruebas , Prueba de Estudio Conceptual , Estudios Retrospectivos , Programas Informáticos , Resultado del Tratamiento
19.
BMC Psychiatry ; 19(1): 124, 2019 04 25.
Artículo en Inglés | MEDLINE | ID: mdl-31023274

RESUMEN

BACKGROUND: The transition phase from inpatient to outpatient care for patients suffering from Major Depressive Disorder represents a vulnerable period associated with a risk of depression worsening and suicide. Our group has recently found that the sleep-wake cycle in discharged depressive patients became irregular and exhibited a drift towards later hours, associated with worsening of depression. In contrast, an advancement of sleep phase has earlier been shown to have an antidepressant effect. Thus, methods to prevent drift of the sleep-wake cycle may be promising interventions to prevent or reduce worsening of depression after discharge. METHODS: In this trial, we apply a new treatment intervention, named Circadian Reinforcement Therapy (CRT), to patients discharged from inpatient psychiatric wards. CRT consists of a specialized psychoeducation on the use of regular time signals (zeitgebers): daylight exposure, exercise, meals, and social contact. The aim is to supply stronger and correctly timed zeitgebers to the circadian system to prevent sleep drift and worsening of depression. The CRT is used in combination with an electronic self-monitoring system, the Monsenso Daybuilder System (MDB). By use of the MDB system, all patients self-monitor their sleep, depression level, and activity (from a Fitbit bracelet) daily. Participants can inspect all their data graphically on the MDB interface and will have clinician contact. The aim is to motivate patients to keep a stable sleep-wake cycle. In all, 130 patients referred to an outpatient service will be included. Depression rating is blinded. Patients will be randomized 1:1 to a Standard group or a CRT group. The intervention period is 4 weeks covering the transition phase from inpatient to outpatient care. The primary outcome is score change in interviewer rated levels of depression on the Hamilton Depression Rating Scale. A subset of patients will be assessed with salivary Dim Light Melatonin Onset (DLMO) as a validator of circadian timing. The trial was initiated in 2016 and will end in 2020. DISCUSSION: If the described intervention is beneficial it could be incorporated into usual care algorithms for depressed patients to facilitate a better and safer transition to outpatient treatment. TRIAL REGISTRATION: Posted prospectively at ClinicalTrials.gov at February 10, 2016 with identifier NCT02679768 .


Asunto(s)
Terapia Conductista/métodos , Ritmo Circadiano/fisiología , Trastorno Depresivo Mayor/terapia , Ejercicio Físico/fisiología , Alta del Paciente , Autocuidado/métodos , Sueño/fisiología , Atención Ambulatoria/métodos , Atención Ambulatoria/psicología , Terapia Combinada/métodos , Trastorno Depresivo Mayor/psicología , Ejercicio Físico/psicología , Femenino , Monitores de Ejercicio , Humanos , Relaciones Interpersonales , Masculino , Fototerapia/métodos , Método Simple Ciego , Terapia Asistida por Computador/instrumentación , Terapia Asistida por Computador/métodos
20.
Phys Med Rehabil Clin N Am ; 30(2): 367-384, 2019 05.
Artículo en Inglés | MEDLINE | ID: mdl-30954153

RESUMEN

Tetraplegia resulting from cervical injury is the most frequent neurologic category after spinal cord injury and causes substantial disability. The residual strength of partially paralyzed muscles is an important determinant of independence and function in tetraplegia. Small improvements in upper extremity function can make a clinically significant difference in daily activities. Major advances in rehabilitation technologies over the past 2 decades have allowed testing of robotic devices in rehabilitation of motor impairments. This literature assessment provides an overview of robotic-assisted training research for improving arm and hand functions after cervical spinal cord injury.


Asunto(s)
Médula Cervical/lesiones , Rehabilitación Neurológica , Robótica , Traumatismos de la Médula Espinal/rehabilitación , Terapia Asistida por Computador , Humanos , Rehabilitación Neurológica/instrumentación , Cuadriplejía/etiología , Cuadriplejía/fisiopatología , Cuadriplejía/rehabilitación , Traumatismos de la Médula Espinal/fisiopatología , Terapia Asistida por Computador/instrumentación , Extremidad Superior/fisiopatología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...