Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 155
Filtrar
1.
In Vivo ; 38(4): 1750-1757, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38936950

RESUMEN

BACKGROUND/AIM: Various devices for non-invasive body shape correction are being developed along with the growth of the beauty industry. Radiofrequency (RF) can selectively reduce subcutaneous fat without causing skin damage. The efficacy of the procedure can be improved by applying RF to a large area simultaneously with multiple handpieces. This study evaluated the safety and efficacy of a new RF device with multi-channel handpieces. MATERIALS AND METHODS: In ex vivo experiments, the RF device was used to treat porcine tissue comprising the skin, subcutaneous, and muscle layers. The device's safety was evaluated by temperature measurements of porcine tissue and histological analysis. In in vivo experiments, the dorsal skin of pigs was treated with the RF device. The safety and efficacy of the device were evaluated by measuring the skin temperature, subcutaneous fat layer thickness, and conducting histological analysis. RESULTS: The skin temperature did not exceed the set temperature during treatment, and skin damage was not observed in histologic analysis in both ex vivo and in vivo experiments. In in vivo experiments, the subcutaneous fat layer thickness and subcutaneous lipocyte size were decreased after treatment. In addition, the fibrous tissue between subcutaneous lipocytes was increased in the RF treatment group compared with the non-treatment group. CONCLUSION: The RF device used in this study effectively reduced the size of subcutaneous lipocytes and increased fibrous tissue without skin damage. Therefore, the safe and effective use of this device for non-invasive fat reduction may be possible in clinical settings.


Asunto(s)
Grasa Subcutánea , Animales , Porcinos , Grasa Subcutánea/citología , Terapia por Radiofrecuencia/métodos , Piel/efectos de la radiación , Contorneado Corporal/métodos , Contorneado Corporal/instrumentación , Tejido Adiposo/citología , Temperatura Cutánea/efectos de la radiación
3.
Maturitas ; 186: 108008, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-38714422

RESUMEN

OBJECTIVE: To compare the effects of fractional CO2 laser and microablative fractional radiofrequency treatment with promestriene topical estrogen on sexual function and genitourinary syndrome of menopause symptoms. METHODS: This was a prospective randomized open-label clinical trial conducted with 62 postmenopausal women assigned to three intervention groups: a) topical promestriene for 90 days (n = 17); b) fractional CO2 laser treatment (n = 24); and c) microablative fractional radiofrequency treatment (n = 21). Each of the latter two groups underwent three treatment sessions at 4-week intervals. At baseline and at the end of the study, all participants had a gynecological examination that included vaginal pH measurement, and the completion of the Vaginal Symptom Score, the Vaginal Health Index, and the Female Sexual Function Index. For the energy treatment groups, adverse effects were evaluated after each session. Group homogeneity was assessed at baseline, and results were evaluated over time (from baseline to the end of treatment) and between groups over time. RESULTS: All baseline parameters were similar among studied groups. At the end of the study, all 3 treatments had produced similar effects: a reduction of vaginal pH, and an improvement of vulvovaginal symptoms (Vaginal Symptom Score and Vaginal Health Index scores) as well as sexual function (higher total Female Sexual Function Index scores, and in the desire, arousal, lubrication and pain domain scores), with no differences observed between groups. Side-effects were slight for both energy treatment groups, mainly represented by vaginal discharge. CONCLUSION: The present study suggests that the two energy treatments were efficient along with promestriene at improving postmenopausal genitourinary and sexuality symptoms. Clinical trial identification numberNCT04717245.


Asunto(s)
Láseres de Gas , Vagina , Humanos , Femenino , Persona de Mediana Edad , Láseres de Gas/uso terapéutico , Estudios Prospectivos , Enfermedades Urogenitales Femeninas/terapia , Síndrome , Menopausia , Estrógenos/uso terapéutico , Administración Intravaginal , Concentración de Iones de Hidrógeno , Disfunciones Sexuales Fisiológicas/terapia , Disfunciones Sexuales Fisiológicas/etiología , Posmenopausia , Terapia por Radiofrecuencia/métodos , Dispareunia/terapia , Dispareunia/etiología , Anciano , Estradiol/análogos & derivados
4.
Lasers Med Sci ; 39(1): 120, 2024 May 02.
Artículo en Inglés | MEDLINE | ID: mdl-38695965

RESUMEN

Cellulite, a perceived alteration in skin topography, is predominantly found in adipose tissue-rich body regions such as the hips, buttocks, thighs, and abdomen. Contrary to common belief, the etiology and pathophysiology of cellulite are not well-established or universally agreed upon. This lack of understanding about the actual etiology of cellulite directly influences the selection of suitable treatments that can address both the aesthetic and inflammatory aspects of the condition. Various treatment methods, including electrophysical agents like electric currents, radiofrequency, ultrasound, and photobiomodulation, have been tested. However, the questionable methodological quality of many studies complicates the determination of effective treatments for cellulite. In this study, we conducted a systematic review of clinical studies that utilized electrophysical agents in cellulite treatment. METHODS: We employed the PICO (population, intervention, control, and outcome) process to develop our search strategy and establish inclusion/exclusion criteria. We searched five databases: Medline, Central, Scopus, Lilacs, and PEDro, for studies conducted between 2001 and July 2021 that involved cellulite treatment with electrophysical agents. To ensure systematicity and guide study selection, we adhered to the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA) guidelines. RESULTS: Our initial search yielded 556 articles: 379 from Medline, 159 from Central, and 18 from Lilacs. After applying our inclusion criteria, only 32 studies remained. Of these, only two (6.2%) were evaluated as having strong and good methodology via the QualSyst tool. CONCLUSIONS: Our findings indicate that the quality of evidence from clinical studies on the use of electrophysical agents for cellulite treatment remains subpar. Further studies with robust experimental designs and more precise assessment techniques are necessary. While our study does not refute the effectiveness of the techniques used for cellulite treatment, it underscores the need for additional well-designed trials.


Asunto(s)
Celulitis , Humanos , Celulitis/terapia , Terapia por Estimulación Eléctrica/métodos , Terapia por Luz de Baja Intensidad/métodos , Ensayos Clínicos como Asunto , Terapia por Radiofrecuencia/métodos
5.
J Cosmet Dermatol ; 23(7): 2401-2410, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38778550

RESUMEN

BACKGROUND: The negative effects of skin aging are primarily related to the destruction of dermal architectural structure. More specifically, this includes changes in the spatial arrangement of collagen, elastin fibers, mucopolysaccharides, proteoglycans, and ground substances. AIMS: The purpose of this study is to investigate the histologic effects of dermal and subdermal tissue after a controlled single treatment with radiofrequency (RF) macroneedling. This therapy provides a controlled, localized, thermal effect on the dermis whereby triggering the body's own healing processes of extracellular matrix remodeling. Clinically benefits include skin tightening. METHODS: Biopsies were obtained for histologic evaluation from four patients (n = 4), 4 weeks after completing a single RF macroneedling facial treatment. RESULTS: Age-related changes of the dermal and subdermal architecture were observed at baseline. After treatment, all biopsies demonstrated an increase in epidermal cells, collagen, elastin, fibroblasts, vasculature, and a decrease in inflammatory cells. CONCLUSIONS: The results of this histologic study confirm a significant "subsurfacing" thermal effect from the noncoagulative ascendant thermal injury. The obtained results characterize RF macroneedling therapy as an effective method for correcting age-related changes in facial skin.


Asunto(s)
Terapia por Radiofrecuencia , Envejecimiento de la Piel , Humanos , Envejecimiento de la Piel/efectos de la radiación , Femenino , Persona de Mediana Edad , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/efectos adversos , Terapia por Radiofrecuencia/instrumentación , Dermis/efectos de la radiación , Dermis/patología , Biopsia , Elastina/metabolismo , Elastina/análisis , Cara , Adulto , Anciano , Colágeno/metabolismo , Fibroblastos/efectos de la radiación , Masculino , Piel/efectos de la radiación , Piel/patología , Técnicas Cosméticas/efectos adversos , Técnicas Cosméticas/instrumentación , Resultado del Tratamiento
6.
Lasers Med Sci ; 39(1): 139, 2024 May 25.
Artículo en Inglés | MEDLINE | ID: mdl-38795173

RESUMEN

BACKGROUND AND AIMS: Hidradenitis suppurativa (HS) is an inflammatory skin disease affecting apocrine gland-bearing sites of the body. Radiofrequency (RF) is a minimally invasive method that acts by minimizing thermal damage to the dermis, resulting in collagen synthesis and scar improvement. We systematically reviewed the efficacy and safety of RF in treating HS. METHODS: A systematic search was performed up to November 18th, 2023, in PubMed/Medline, Ovid Embase, and Web of Science. Clinical studies with English full texts were included. The National Institute of Health (NIH) Quality Assessment Tool for clinical trials and Methodological quality and synthesis of case series and case reports by Murad et al. were utilized for critical appraisal. RESULTS: Out of 55 identified studies, 11 met our inclusion criteria with 167 subjects who underwent RF therapy alone or combined with an intense pulsed laser (IPL), known as LAight®. LAight® significantly improved clinical outcomes in mild-to-moderate HS patients based on the Dermatology Life Quality Index (DLQI), International Hidradenitis Suppurativa Score System (IHS4), Pain-Numerical Rating Scale (NRS), and Hidradenitis Suppurativa Clinical Response (HiSCR). Moreover, RF therapy alone significantly alleviated the clinical manifestations in patients with mild-to-moderate HS. Additionally, fractional microneedling RF significantly decreased HS-associated inflammatory markers. RF was found to be safe with limited adverse events. However, in moderate-to-severe HS, RF has failed to yield satisfactory results. CONCLUSION: RF is a safe energy-based method with promising outcomes, especially for long-term application in mild-to-moderate HS. In moderate-to-severe cases, RF should be combined with a systemic medication for further beneficial impacts.


Asunto(s)
Hidradenitis Supurativa , Terapia por Radiofrecuencia , Hidradenitis Supurativa/radioterapia , Hidradenitis Supurativa/cirugía , Hidradenitis Supurativa/terapia , Humanos , Terapia por Radiofrecuencia/métodos , Resultado del Tratamiento , Calidad de Vida
7.
J Cosmet Dermatol ; 23(7): 2420-2426, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38532267

RESUMEN

OBJECTIVE: To investigate the histological properties of microplasma radiofrequency (MPRF) using a stationary tip in different treatment strategies on porcine skin. METHODS: Two Bama miniature pigs received MPRF treatment with two types of stationary tips in eight groups of parameters (power, duration, and pass) on dorsal skin. Skin samples were collected from each treatment zone immediately, at 1 week and 1, 3, and 6 months after treatment. Hematoxylin and eosin (HE) and Masson staining were performed to assess histologic changes as well as neocollagenesis. The dynamic changes of heat shock protein 47 (HSP47) and heat shock protein 72 (HSP72) were also detected by immunohistochemistry. RESULTS: Skin damage increased with pulse energy, duration, and pass. Longer durations or repeated treatments may cause particularly severe skin damage. During the wound healing process, the newborn collagen of the dermis is rearranged. The distribution of HSP47 and HSP72 was consistent with the extent of collagen remodeling. It peaked 1 month after treatment. CONCLUSION: MPRF can effectively cause epidermal ablation, dermal collagen hyperplasia, and remodeling. Increasing power should be the first choice when increasing treatment intensity. For longer durations or repeated treatments, caution should be taken to avoid excessive skin trauma.


Asunto(s)
Piel , Porcinos Enanos , Animales , Porcinos , Piel/efectos de la radiación , Piel/patología , Cicatrización de Heridas/efectos de la radiación , Proteínas del Choque Térmico HSP47/metabolismo , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/efectos adversos , Terapia por Radiofrecuencia/instrumentación , Colágeno/metabolismo , Proteínas del Choque Térmico HSP72/metabolismo , Proteínas del Choque Térmico HSP72/análisis , Ondas de Radio/efectos adversos
8.
J Cosmet Dermatol ; 23(7): 2433-2442, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38532647

RESUMEN

BACKGROUND: Microplasma fractional radiofrequency (MP FRF) technology has been increasingly used for acne scars. Nevertheless, little evidence has analyzed the factors influencing its effectiveness before and during treatment. AIMS: To evaluate the clinical factors affecting the effectiveness of MP FRF therapy for atrophic acne scars. METHODS: We analyzed retrospectively the clinical data of 79 acne scar patients treated with MP FRF technology. The outcome of interest included the effectiveness and adverse events after MP FRF treatment. Multivariable logistic regression was utilized to evaluate clinical factors associated with effectiveness after the initial session. RESULTS: All patients received 115 sessions of MP FRF therapy (average: 1.5 sessions). Twenty-eight (35.4%) patients improved moderately to excellently after one session. We found that the severe grade before treatment was negatively correlated with the effectiveness according to Goodman-Baron qualitative scores (OR = 0.02, 95% CI [0.001, 0.37], p = 0.009). The presence of icepick scars was also a negative correlation factor for the effectiveness (OR = 0.06, 95% CI [0.004, 1.00], p = 0.049). Furthermore, after excluding the effects of icepick scars and Goodman-Baron scores before treatment, ECCA scores were also correlated with effectiveness (OR = 1.04, 95% CI [1.01, 1.06], p = 0.009). CONCLUSION: MP FRF therapy was effective in treating atrophic acne scars with no permanent adverse events. The severity of Goodman-Baron qualitative scores and icepick scars were independent clinical factors affecting effectiveness, suggesting the possible requirement for additional treatments other than MP FRF for severe acne scars and icepick scars.


Asunto(s)
Acné Vulgar , Atrofia , Cicatriz , Humanos , Acné Vulgar/complicaciones , Acné Vulgar/terapia , Estudios Retrospectivos , Cicatriz/etiología , Cicatriz/terapia , Cicatriz/diagnóstico , Femenino , Adulto , Masculino , Resultado del Tratamiento , Adulto Joven , Atrofia/etiología , Índice de Severidad de la Enfermedad , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/efectos adversos , Adolescente , Tratamiento de Radiofrecuencia Pulsada/métodos
9.
Radiol Med ; 129(5): 794-806, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38512629

RESUMEN

BACKGROUND: Lumbar facet joint pain (LFJP) is one of the main causes of chronic low back pain (LBP) and can be treated using radiofrequency (RF) sensory denervation. The aim of this work is to analyze the efficacy of RF in LFJP through a systematic review and meta-analysis of randomized controlled trials (RCTs) with placebo control. MATERIALS AND METHODS: A systematic search was conducted in the Medline (PubMed), Scopus, Web of Science databases, and the Cochrane Central Register of Controlled Trials (CENTRAL). The variables of interest were pain, functional status, quality of life (QoL), and global perceived effect (GPE) measured at different time intervals: short (< 3 months), medium (> 3 and < 12 months), and long term (> 12 months). RESULTS: Eight RCTs with placebo control were included. RF showed significant benefits over placebo in pain relief in the short (MD - 1.01; 95% CI - 1.98 to -0.04; p = 0.04), medium (MD - 1.42; 95% CI - 2.41 to - 0.43; p = 0.005), and long term (MD - 1.12; 95% CI - 1.57 to - 0.68; p < 0.001), as well as improvement in functional disability in the short (SMD - 0.94; 95% CI - 1.73 to - 0.14; p = 0.02) and long term (SMD - 0.74; 95% CI - 1.09 to - 0.39; p < 0.001). No statistically significant differences were observed in QoL or quantitative GPE, but benefits for RF were observed in dichotomous GPE in the medium (OR 0.19; 95% CI 0.07-0.52; p = 0.001) and long term (OR 0.22; 95% CI 0.06-0.78; p = 0.02). Subgroup analyses showed more benefits for RF in LBP < 1 year in the short term and in RCTs that did not require performing an MRI for patient selection. CONCLUSIONS: RF demonstrated significant improvement in pain and functionality, but the benefits in terms of QoL and GPE are inconclusive. Future clinical trials should investigate the long-term effects of RF, its impact on quality of life, and define appropriate criteria for patient selection.


Asunto(s)
Dolor de la Región Lumbar , Ensayos Clínicos Controlados Aleatorios como Asunto , Articulación Cigapofisaria , Humanos , Articulación Cigapofisaria/diagnóstico por imagen , Dolor de la Región Lumbar/terapia , Vértebras Lumbares , Calidad de Vida , Resultado del Tratamiento , Dimensión del Dolor , Terapia por Radiofrecuencia/métodos , Desnervación/métodos
10.
J Cosmet Dermatol ; 23(6): 2030-2043, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38450826

RESUMEN

BACKGROUND: Vulvovaginal atrophy (VVA) includes a wide range of conditions affecting the reproductive and urinary systems, often requiring careful evaluation and management for optimal health. AIMS: This study aims to evaluate the symptom management effects of a real time temperature-monitored non-ablative RF device for the treatment of postmenopausal Chinese women with VVA symptoms. METHODS: This pilot study involved 24 postmenopausal Chinese women with one or more VVA symptoms, who wished to remain sexually active. VHIS, VAS, and FSFI were used to track and evaluate various aspects of the patient's condition. Analyses were conducted at the end of the study to verify the statistical significance of the treatment's results. RESULTS: All patients reported substantial, statistically significant, improvements on every VVA symptom tracked. Approximately 80% of the patients reported total symptom reversal at 12-week post-treatment follow-up. CONCLUSION: This pilot study demonstrated that non-ablative, monopolar RF technology equipped with real time temperature monitoring is feasible and safe in the treatment of postmenopausal women with VVA symptoms, and efficacious at up to 12 weeks post-treatment.


Asunto(s)
Atrofia , Posmenopausia , Vagina , Vulva , Humanos , Femenino , Proyectos Piloto , Persona de Mediana Edad , Vagina/patología , Vulva/patología , Vulva/efectos de la radiación , China , Resultado del Tratamiento , Anciano , Enfermedades Vaginales/terapia , Enfermedades Vaginales/patología , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/efectos adversos , Terapia por Radiofrecuencia/instrumentación , Monitoreo Fisiológico/métodos , Monitoreo Fisiológico/instrumentación , Pueblo Asiatico , Pueblos del Este de Asia
11.
J Sex Med ; 21(5): 430-442, 2024 Apr 30.
Artículo en Inglés | MEDLINE | ID: mdl-38508858

RESUMEN

BACKGROUND: Despite several treatments that have been used for women reporting vaginal laxity (VL), to our knowledge no systematic review is available on the topic so far. AIM: In this study, we sought to summarize the best available evidence about the efficacy and safety of interventions for treating VL, whether conservative or surgical. METHODS: A comprehensive search strategy was performed in Medline, Embase, Scopus, Web of Science, and Cochrane Library for reports of clinical trials published from database inception to September 2022. Studies selected for inclusion were in the English language and were performed to investigate any type of treatment for VL, with or without a comparator, whether nonrandomized studies or randomized controlled trials (RCTs). Case reports and studies without a clear definition of VL were excluded. OUTCOMES: The outcomes were interventions (laser, radiofrequency, surgery, and topical treatment), adverse effects, sexual function, pelvic floor muscle (PFM) strength, and improvement of VL by the VL questionnaire (VLQ). RESULTS: From 816 records, 38 studies remained in the final analysis. Laser and radiofrequency (RF) were the energy-based treatment devices most frequently studied. Pooled data from eight observational studies have shown improved sexual function assessed by a Female Sexual Function Index score mean difference (MD) of 6.51 (95% CI, 5.61-7.42; i2 = 85%, P < .01) before and after intervention, whether by RF (MD, 6.00; 95% CI, 4.26-7.73; i2 = 80%; P < .001) or laser (MD, 6.83; 95% CI, 5.01-8.65; i2 = 92%; P < .01). However, this finding was not shown when only 3 RCTs were included, even when separated by type of intervention (RF or laser). When RF treatment was compared to sham controls, VLQ scores did not improve (MD, 1.01; 95% CI, -0.38 to 2.40; i2 = 94%; P < .001). Patient PFM strength improved after interventions were performed (MD, 4.22; 95% CI, 1.02-7.42; i2 = 77%; P < .001). The ROBINS-I (Risk Of Bias In Nonrandomized Studies of Interventions) tool classified all non-RCTs at serious risk of bias, except for 1 study, and the risk of bias-1 analysis found a low and unclear risk of bias for all RCTs. The GRADE (Grading of Recommendations, Assessment, Development, and Evaluations) certainty of the evidence was moderate for sexual function and the VLQ questionnaire and low for PFM strength. CLINICAL IMPLICATIONS: Sexual function in women with VL who underwent RF and laser treatment improved in observational studies but not in RCTs. Improvement in PFM strength was observed in women with VL after the intervention. STRENGTHS AND LIMITATIONS: Crucial issues were raised for the understanding of VL, such as lack of standardization of the definition and for the development of future prospective studies. A limitation of the study was that the heterogeneity of the interventions and different follow-up periods did not make it possible to pool all available data. CONCLUSIONS: Vaginal tightening did not improve sensation in women with VL after intervention, whereas RF and laser improved sexual function in women with VL according to data from observational studies, but not from RCTs. PFM strength was improved after intervention in women with VL.


Asunto(s)
Vagina , Humanos , Femenino , Vagina/cirugía , Terapia por Láser/métodos , Diafragma Pélvico/fisiopatología , Terapia por Radiofrecuencia/métodos , Disfunciones Sexuales Fisiológicas/terapia
12.
J Cosmet Dermatol ; 23(5): 1620-1628, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38468421

RESUMEN

BACKGROUND: Skin's exposure to intrinsic and extrinsic factors causes age-related changes, leading to a lower amount of dermal collagen and elastin. AIM: This study investigated the effects of a novel facial muscle stimulation technology combined with radiofrequency (RF) heating on dermal collagen and elastin content for the treatment of facial wrinkles and skin laxity. METHODS: The active group subjects (N = 6) received four 20-min facial treatments with simultaneous RF and facial muscle stimulation, once weekly. The control subject (N = 1) was untreated. Skin biopsies obtained at baseline, 1-month and 3-month follow-up were evaluated histologically to determine collagen and elastin fibers content. A group of independent aestheticians evaluated facial skin appearance and wrinkle severity. Patient safety was followed. RESULTS: In the active group, collagen-occupied area reached 11.91 ± 1.80 × 106 µm2 (+25.32%, p < 0.05) and 12.35 ± 1.44 × 105 µm2 (+30.00%, p < 0.05) at 1-month and 3-month follow-up visits. Elastin-occupied area at 1-month and 3-month follow-up was 1.64 ± 0.14 × 105 µm2 (+67.23%, p < 0.05), and 1.99 ± 0.21 × 105 µm2 (+102.80%, p < 0.05). In the control group, there was no significant difference (p > 0.05) in collagen and elastin fibers. Active group wrinkle scores decreased from 5 (moderate, class II) to 3 (mild, class I). All subjects, except the control, improved in appearance posttreatment. No adverse events or side effects occurred. CONCLUSION: Decreased dermal collagen and elastin levels contributes to a gradual decline in skin elasticity, leading to facial wrinkles and unfirm skin. Study results showed noticeable improvement in facial appearance and increased dermal collagen and elastin content subsequent to simultaneous, noninvasive RF, and facial muscle stimulation treatments.


Asunto(s)
Colágeno , Elastina , Músculos Faciales , Envejecimiento de la Piel , Humanos , Elastina/análisis , Elastina/metabolismo , Envejecimiento de la Piel/efectos de la radiación , Colágeno/metabolismo , Colágeno/análisis , Femenino , Persona de Mediana Edad , Adulto , Músculos Faciales/efectos de la radiación , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/efectos adversos , Masculino , Terapia por Estimulación Eléctrica/efectos adversos , Terapia por Estimulación Eléctrica/instrumentación , Terapia por Estimulación Eléctrica/métodos , Técnicas Cosméticas/efectos adversos , Técnicas Cosméticas/instrumentación , Piel/efectos de la radiación , Piel/patología , Cara , Biopsia , Resultado del Tratamiento
13.
Lasers Surg Med ; 56(3): 298-304, 2024 03.
Artículo en Inglés | MEDLINE | ID: mdl-38304960

RESUMEN

OBJECTIVES: This study aims to evaluate the safety of the radiofrequency device and its efficacy in various treatment and refrigeration modes. METHODS: Four 4-week Bama miniature pigs were used in this study, and four repeated treatment sites were selected on the pig's abdomen, each site consisting of 6 different treatment and cooling modes, with radiofrequency device (YouMagic; WE Medical Technology Co., Ltd.) administered every 3-5 s for a total of five treatments. The handheld infrared thermometer (HIKMICRO; Hangzhou Hikmicro Sensing Technology Co., Ltd.) was used to monitor the surface temperature of skin. Twenty minutes after the completion of treatment, a biopsy of the treatment and control area was performed on the pigs using a 4-mm biopsy punch. One-month after the treatment, samples were obtained using surgical scalpels. After that we used proper staining to estimate the therapeutic efficacy. At last, SPSS and Image J were used to proceed to the next step of analysis. RESULTS: During the therapy, no side effects were observed apart from mild transient erythema caused by the heating of skin temperature, staining of biopsy samples taken 20 min after treatment showed no serious damage of dermis. After 1 month of treatment, it can increase collagen I and elastin production. In addition, increases in energy setting at a standard pass number also increased the expression of collagen I. Meanwhile, we also found an increase in the thickness of the dermal layer among all treatment groups. CONCLUSIONS: The new monopolar radiofrequency instrument possesses excellent therapeutic safety. After 1 month of treatment, it can increase collagen I and elastin production in 2-month-old Bama miniature pigs.


Asunto(s)
Terapia por Radiofrecuencia , Porcinos , Animales , Porcinos Enanos/metabolismo , Terapia por Radiofrecuencia/métodos , Modelos Animales , Colágeno/metabolismo , Elastina
14.
J Cosmet Dermatol ; 23(6): 2022-2029, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38385807

RESUMEN

BACKGROUND: Striae distensae (SD) is a challenging cosmetic condition. Ablative fractional laser (AFL) is an effective method for treating SD. Recently, fractional radiofrequency (FRF) has been shown to be a promising treatment for SD; however, few studies have shown the differences between FRF and AFL in the treatment of SD. AIMS: This study aimed to evaluate and compare the clinical efficacy and safety of bipolar FRF with 2940-nm erbium yttrium aluminum garnet (Er:YAG) AFL in the treatment of SD. PATIENTS/METHODS: Twenty volunteers with abdominal SD were enrolled in this study. One half of the abdomen was treated with 2940-nm Er:YAG AFL, whereas the other half was treated with bipolar FRF, with three sessions at 4-week intervals. Photographic evaluations of clinical improvement were conducted by two independent investigators before and after treatment, and the patients provided self-assessments. Two participants underwent three punch biopsies, one before treatment and two obtained from bilateral representative skin lesions on the abdomen 3 months following the final treatment. RESULTS: Clinical improvements were observed in SD on both sides of the abdomen after the two treatments. Post-treatment skin biopsies revealed increased thickness in the epidermis and dermis, and higher collagen and elastin density compared to those at the baseline. No statistically significant differences were observed in the clinical outcomes between the two treatment approaches. CONCLUSIONS: The efficacy and safety of bipolar FRF treatment are comparable to those of 2940-nm Er:YAG AFL treatment, providing an alternative and effective treatment for SD.


Asunto(s)
Láseres de Estado Sólido , Estrías de Distensión , Humanos , Estrías de Distensión/terapia , Láseres de Estado Sólido/uso terapéutico , Láseres de Estado Sólido/efectos adversos , Femenino , Adulto , Resultado del Tratamiento , Adulto Joven , Masculino , Abdomen , Piel/efectos de la radiación , Piel/patología , Terapia por Radiofrecuencia/efectos adversos , Terapia por Radiofrecuencia/métodos , Terapia por Radiofrecuencia/instrumentación , Biopsia/efectos adversos , Satisfacción del Paciente
15.
Rhinology ; 62(3): 310-319, 2024 Jun 01.
Artículo en Inglés | MEDLINE | ID: mdl-38217847

RESUMEN

BACKGROUND: Temperature-controlled radiofrequency (TCRF) device treatment of nasal valve dysfunction (NVD) was superior to a sham procedure control in reducing the symptoms of nasal airway obstruction (NAO) in this randomised controlled trial (RCT). METHODOLOGY: Two-year outcomes for 108 patients actively treated in a prospective, multicenter, patient-blinded RCT were used to determine treatment effect durability and changes in medication/nasal dilator usage. A responder was defined as ≥ 20 reduction in NOSE score or 1 reduction in severity class. RESULTS: The mean (SD) age of patients was 48.5 (12.3) years; 66 (61.1%) women. Baseline NOSE score was 76.3. The 2-year responder rate was 90.4% and NOSE score treatment effect was -41.7; 54.7% improvement. Of 57 patients using medications/nasal dilators at baseline, 45 (78.9%) either stopped all use (33.3%) or stopped/decreased (45.6%) use in >=1 class at 2 years. Concurrent septal deviation, septal swell body, or turbinate enlargement did not significantly affect the odds of exhibiting a NOSE score of ≤ 25 at 2 years. CONCLUSIONS: TCRF device treatment of NVD resulted in significant and sustained improvements in the symptoms of NAO at 2 years, accompanied by a substantial reduction in medication/nasal dilator use.


Asunto(s)
Obstrucción Nasal , Humanos , Obstrucción Nasal/cirugía , Femenino , Persona de Mediana Edad , Masculino , Estudios Prospectivos , Resultado del Tratamiento , Adulto , Terapia por Radiofrecuencia/métodos
16.
Int J Gynaecol Obstet ; 166(1): 163-172, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-38102987

RESUMEN

BACKGROUND: Energy-based devices (laser and radiofrequency) have been used to treat genitourinary syndrome of menopause (GSM). OBJECTIVES: To evaluate the efficacy and safety of physical energy use in managing GSM symptoms. SEARCH STRATEGY: Five databases were searched from inception to December 2022. Language restrictions were not imposed. SELECTION CRITERIA: We included all Cochrane and non-Cochrane systematic reviews with or without meta-analyses that described postmenopausal women with symptoms of GSM treated with physical energy. DATA COLLECTION AND ANALYSIS: We performed a network meta-analysis using frequentist methods to calculate standardized mean differences (SMDs) and their corresponding 95% confidence intervals (CIs). Methodological and reporting quality were assessed using the Assessment of Multiple Systematic Reviews (AMSTAR 2). MAIN RESULTS: Nine reviews were included in the overview, six of which were meta-analyses. Four randomized controlled trials, representing 218 participants and nine different study arms, met the criteria for inclusion in our component network meta-analysis. Confidence in review findings was low in six reviews and critically low in three. Our network meta-analysis results showed that premarin (SMD 2.60, 95% CI 7.76-3.43), conjugated estrogens (SMD 2.13, 95% CI 1.34-2.91), carbon dioxide laser (SMD 1.71, 95% CI 1.10-2.31), promestriene (SMD 1.41, 95% CI 0.59-2.24), and vaginal lubricant (SMD 1.37, 95% CI 0.54-2.20) were more effective than sham for reducing sexual dysfunction, with a consequent increase in Female Sexual Function Index (FSFI). Two studies showed a high risk of bias, owing to a lack of blinding. CONCLUSION: Several gaps in the use of physical energy for managing GSM still need to be addressed. The small number of blind clinical trials made the results fragile.


Asunto(s)
Enfermedades Urogenitales Femeninas , Menopausia , Metaanálisis en Red , Humanos , Femenino , Enfermedades Urogenitales Femeninas/terapia , Síndrome , Terapia por Radiofrecuencia/métodos , Terapia por Láser/métodos
17.
Zhonghua Yi Xue Za Zhi ; 103(15): 1134-1139, 2023 Apr 18.
Artículo en Chino | MEDLINE | ID: mdl-37055231

RESUMEN

Objective: To assess the efficacy and safety of modified Hartel approach in the treatment of primary trigeminal neuralgia with radiofrequency thermocoagulation. Methods: A total of 89 patients with primary trigeminal neuralgia in Nanjing Drum Tower Clinical College of Xuzhou Medical University from July 2021 to July 2022 were prospectively included, and were divided into experimental group (n=45, modified Hartel approach: selecting 2.0 cm lateral to and 1.0 cm below angulus oris as insertion point) and control group (n=44, traditional Hartel approach: selecting 2.5 cm lateral to the angulus oris as insertion point) according to the random number table method. There were 19 males and 26 females in the experimental group, and aged (67.6±8.8) years. Meanwhile, there were 19 males and 25 females in the control group, and aged (64.8±11.7) years. All the patients were treated by CT-guided radiofrequency thermocoagulation. The success rate of one-time puncture, number of punctures, the time of puncture, operation time, numerical rating scale (NRS) scores and complications were recorded and compared between the two groups. Results: The success rate of one-time puncture in experimental group was 64.4% (29/45), which was higher than that in control group 31.8% (14/44) (P<0.05). The number of punctures [M (Q1, Q3)], the time of puncture [M (Q1, Q3)] and operation time in the experimental group were 1 (1, 2), 218 (206, 378) s, (19.9±2.7) min, which were less than those of control group [2 (1, 3), 390 (231, 598) s, (27.0±3.9) min] (all P<0.05). The NRS scores [M (Q1, Q3)] of 1 day, 1 month and 3 months after surgery in the experimental group were 1 (1, 2), 1 (0, 2) and 1(0, 1), respectively, which were lower than the baseline level [6 (6, 7)] (all P<0.05). The NRS scores [M (Q1, Q3)] of 1 day, 1 month and 3 months after surgery in the control group were 1 (1, 2), 1 (0, 2) and 1 (0, 2), respectively, which were lower than the baseline level [6 (6, 7)] (all P<0.05). There was no statistically significant difference in the incidence of nausea and vomiting, facial numbness, and decreased masticatory muscle strength between the two groups (all P>0.05) In the experimental group, two patients had puncture needles into the oral cavity, with timely detection and replacement of puncture needles, and no infection occurred. There was no cerebrospinal fluid leakage and decreased corneal reflex in both groups. Conclusion: The modified Hartel approach can significantly improve the success rate of one-time puncture via foramen ovale, reduce the operation time and the incidence of postoperative facial swelling, which is a safe and effective puncture method.


Asunto(s)
Terapia por Radiofrecuencia , Neuralgia del Trigémino , Masculino , Femenino , Humanos , Neuralgia del Trigémino/cirugía , Resultado del Tratamiento , Electrocoagulación/métodos , Terapia por Radiofrecuencia/métodos , Punciones
18.
Sci Rep ; 13(1): 1362, 2023 01 24.
Artículo en Inglés | MEDLINE | ID: mdl-36693895

RESUMEN

Drug treatment of limb frostbite injuries is complicated due to the poor delivery of medications to affected tissues. External rewarming of the frostbitten area is risky and does not always result in positive outcomes because the dilatation of superficial vessels with constricted deep vessels can lead to irreversible damage, necrosis, and amputation. One of the techniques to restore perfusion of deep vessels in an affected extremity is rewarming with low-power microwave radiation in a specially designed metal chamber. Below are findings following treatment of 14 volunteers with this technique in 2 Tomsk hospitals during winters of 2018-2021. It is demonstrated that timely, i.e. in the early reactive period, application of microwave radiation and appropriate supportive drug treatment results in positive amputation-free outcomes. The key requirement is prompt thermal insulation of the trauma and no prior exposure to external heat sources.


Asunto(s)
Congelación de Extremidades , Terapia por Radiofrecuencia , Recalentamiento , Humanos , Extremidades , Calor , Microondas/uso terapéutico , Recalentamiento/métodos , Congelación de Extremidades/terapia , Terapia por Radiofrecuencia/métodos , Amputación Quirúrgica
19.
Facial Plast Surg Aesthet Med ; 24(S1): S3-S10, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-36103270

RESUMEN

Importance: Minimally invasive methods for skin rejuvenation are in high demand. A diverse array of minimally invasive devices has been developed for aesthetical purposes and should be considered to help patients achieve their goals. Observations: Radiofrequency (RF) microneedling is a safe and effective intervention for treatment of various aesthetical and dermatological conditions in all skin types. This review highlights Morpheus8 (InMode, Inc., Irvine, CA) and what differentiates it from other similar devices. Conclusions and Relevance: RF microneedling addresses aesthetical and dermatological concerns for a diverse variety of patients in whom surgical intervention may not be desired. Morpheus8 has unique technological properties and advances that make it the preferred device for many practices.


Asunto(s)
Técnicas Cosméticas , Terapia por Radiofrecuencia , Envejecimiento de la Piel , Cirujanos , Humanos , Agujas , Terapia por Radiofrecuencia/métodos
20.
Med Sci Monit ; 28: e933848, 2022 Feb 23.
Artículo en Inglés | MEDLINE | ID: mdl-35194010

RESUMEN

BACKGROUND This retrospective study from 2 centers in Beijing, China aimed to assess the safety and efficacy of endoscopic radiofrequency therapy under direct vision in 59 patients with gastroesophageal reflux disease (GERD) using the gastroesophageal reflux disease questionnaire (GerdQ). MATERIAL AND METHODS Fifty-nine GERD patients who underwent endoscopic radiofrequency treatment were included. Patients were divided into 2 groups: the endoscopic radiofrequency therapy under direct vision group and the non-direct vision radiofrequency therapy group. Indicators such as GerdQ score, lower esophageal sphincter (LES) pressure, DeMeester score, acid exposure time, and proton pump inhibitors (PPIs) use were collected before and after radiofrequency treatment. Postoperative complications were also recorded. The efficacy and safety of endoscopic radiofrequency therapy under direct vision were evaluated by comparing the indicators of patients in the 2 groups. RESULTS At 3 months after radiofrequency treatment, patients in the endoscopic radiofrequency therapy under direct vision group improved significantly in GerdQ score, decreased from 11.0 (10.0, 12.0) to 6.0 (6.0, 8.0), better than patients in the non-direct vision radiofrequency therapy group, and the better improvements remained at 12 months after the procedure (P<0.05). At 6 months after treatment, patients in the endoscopic radiofrequency therapy under direct vision group had significant improvements in LES pressure, which increased from 8.15 (3.18, 12.88) mmHg to 15.20 (10.25, 27.03) mmHg (P<0.05). There were no severe complications in our trial. CONCLUSIONS When compared with non-visualized endoscopic radiofrequency therapy, treatment under direct vision was safer and improved the GerdQ score and LES pressure at up to 12 months.


Asunto(s)
Reflujo Gastroesofágico/terapia , Terapia por Radiofrecuencia/métodos , Encuestas y Cuestionarios , Beijing/epidemiología , Endoscopía Gastrointestinal/métodos , Femenino , Estudios de Seguimiento , Reflujo Gastroesofágico/diagnóstico , Reflujo Gastroesofágico/epidemiología , Humanos , Masculino , Persona de Mediana Edad , Prevalencia , Estudios Retrospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...