Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.535
Filtrar
1.
J Cardiovasc Med (Hagerstown) ; 25(7): 473-487, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38829936

RESUMEN

Cardiovascular magnetic resonance (CMR) and computed tomography (CCT) are advanced imaging modalities that recently revolutionized the conventional diagnostic approach to congenital heart diseases (CHD), supporting echocardiography and often replacing cardiac catheterization. This is the second of two complementary documents, endorsed by experts from the Working Group of the Italian Society of Pediatric Cardiology and the Italian College of Cardiac Radiology of the Italian Society of Medical and Interventional Radiology, aimed at giving updated indications on the appropriate use of CMR and CCT in different clinical CHD settings, in both pediatrics and adults. In this article, support is also given to radiologists, pediatricians, cardiologists, and cardiac surgeons for indications and appropriateness criteria for CMR and CCT in the most referred CHD, following the proposed new criteria presented and discussed in the first document. This second document also examines the impact of devices and prostheses for CMR and CCT in CHD and additionally presents some indications for CMR and CCT exams when sedation or narcosis is needed.


Asunto(s)
Consenso , Cardiopatías Congénitas , Humanos , Cardiopatías Congénitas/diagnóstico por imagen , Cardiopatías Congénitas/terapia , Italia , Tomografía Computarizada por Rayos X/normas , Cardiología/normas , Imagen por Resonancia Magnética/normas , Niño , Valor Predictivo de las Pruebas , Adulto , Sociedades Médicas/normas
2.
Neuroimage ; 294: 120631, 2024 Jul 01.
Artículo en Inglés | MEDLINE | ID: mdl-38701993

RESUMEN

INTRODUCTION: Spatial normalization is a prerequisite step for the quantitative analysis of SPECT or PET brain images using volume-of-interest (VOI) template or voxel-based analysis. MRI-guided spatial normalization is the gold standard, but the wide use of PET/CT or SPECT/CT in routine clinical practice makes CT-guided spatial normalization a necessary alternative. Ventricular enlargement is observed with aging, and it hampers the spatial normalization of the lateral ventricles and striatal regions, limiting their analysis. The aim of the present study was to propose a robust spatial normalization method based on CT scans that takes into account features of the aging brain to reduce bias in the CT-guided striatal analysis of SPECT images. METHODS: We propose an enhanced CT-guided spatial normalization pipeline based on SPM12. Performance of the proposed pipeline was assessed on visually normal [123I]-FP-CIT SPECT/CT images. SPM12 default CT-guided spatial normalization was used as reference method. The metrics assessed were the overlap between the spatially normalized lateral ventricles and caudate/putamen VOIs, and the computation of caudate and putamen specific binding ratios (SBR). RESULTS: In total 231 subjects (mean age ± SD = 61.9 ± 15.5 years) were included in the statistical analysis. The mean overlap between the spatially normalized lateral ventricles of subjects and the caudate VOI and the mean SBR of caudate were respectively 38.40 % (± SD = 19.48 %) of the VOI and 1.77 (± 0.79) when performing SPM12 default spatial normalization. The mean overlap decreased to 9.13 % (± SD = 1.41 %, P < 0.001) of the VOI and the SBR of caudate increased to 2.38 (± 0.51, P < 0.0001) when performing the proposed pipeline. Spatially normalized lateral ventricles did not overlap with putamen VOI using either method. The mean putamen SBR value derived from the proposed spatial normalization (2.75 ± 0.54) was not significantly different from that derived from the default SPM12 spatial normalization (2.83 ± 0.52, P > 0.05). CONCLUSION: The automatic CT-guided spatial normalization used herein led to a less biased spatial normalization of SPECT images, hence an improved semi-quantitative analysis. The proposed pipeline could be implemented in clinical routine to perform a more robust SBR computation using hybrid imaging.


Asunto(s)
Cuerpo Estriado , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Adulto , Cuerpo Estriado/diagnóstico por imagen , Cuerpo Estriado/metabolismo , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada de Emisión de Fotón Único/métodos , Ventrículos Cerebrales/diagnóstico por imagen , Ventrículos Cerebrales/metabolismo , Procesamiento de Imagen Asistido por Computador/métodos , Tropanos
3.
BMJ Open Qual ; 13(2)2024 Apr 24.
Artículo en Inglés | MEDLINE | ID: mdl-38663928

RESUMEN

INTRODUCTION: At Sandwell General Hospital, there was no risk stratification tool or pathway for head injury (HI) patients presenting to the emergency department (ED). This resulted in significant delays in the assessment of HI patients, compromising patient safety and quality of care. AIMS: To employ quality improvement methodology to design an effective adult HI pathway that: ensured >90% of high-risk HI patients being assessed by ED clinicians within 15 min of arrival, reduce CT turnaround times, and aiming to keep the final decision making <4 hours. METHODS: SWOT analysis was performed; driver diagrams were used to set out the aims and objectives. Plan-Do-Study-Act cycle was used to facilitate the change and monitor the outcomes. Process map was designed to identify the areas for improvement. A new HI pathway was introduced, imaging and transporting the patients was modified, and early decisions were made to meet the standards. RESULTS: Data were collected and monitored following the interventions. The new pathway improved the proportion of patients assessed by the ED doctors within 15 min from 31% to 63%. The average time to CT head scan was decreased from 69 min to 53 min. Average CT scan reporting time also improved from 98 min to 71 min. Overall, the average time to decision for admission or discharge decreased from 6 hours 48 min to 4 hours 24 min. CONCLUSIONS: Following implementation of the new HI pathway, an improvement in the patient safety and quality of care was noted. High-risk HI patients were picked up earlier, assessed quicker and had CT head scans performed sooner. Decision time for admission/discharge was improved. The HI pathway continues to be used and will be reviewed and re-audited between 3 and 6 months to ensure the sustained improvement.


Asunto(s)
Traumatismos Craneocerebrales , Servicio de Urgencia en Hospital , Mejoramiento de la Calidad , Humanos , Servicio de Urgencia en Hospital/organización & administración , Servicio de Urgencia en Hospital/estadística & datos numéricos , Traumatismos Craneocerebrales/terapia , Adulto , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Tomografía Computarizada por Rayos X/normas , Masculino , Femenino
4.
Radiography (Lond) ; 30(3): 821-826, 2024 May.
Artículo en Inglés | MEDLINE | ID: mdl-38520958

RESUMEN

INTRODUCTION: The National Institute for Health and Care Excellence (NICE) recommends that GPs initially refer patients with suspected lung cancer for a chest X-ray (CXR). The Radiology department has a 'fast track system' to identify those patients who may have lung cancer on CXR and are referred for a CT thorax with contrast to help determine a cancer diagnosis. This fast track system was put in place to ensure the NICE guidelines and NHS England's standards on a faster cancer diagnosis are being met. This audit studied the ability of radiologists and reporting radiographers to identify lung cancer on CXRs and the accuracy of the fast-track system. METHODS: 846 cases with lung alerts were analysed and 545 CXRs were audited. The CXRs were split into images reported by radiologists (168) and those reported by reporting radiographers (377). CT thorax results were collected through PACS and Cerner computer systems to identify if the 'fast track' system had yielded a "positive", "negative", or "other findings" result for lung cancer. RESULTS: 32.8% (179) of CXRs flagged for lung cancer were positive, 40.6% (221) were negative, and 26.6% (145) had other findings. Chi square statistical test showed no significant difference (p = 0.14) between the two reporting groups in their ability to identify lung cancer on CXRs. 27% (38) of CXRs flagged by radiologists and 35% (125) by reporting radiographers were positive for lung cancer. CONCLUSION: This clinical audit indicates, reporting radiographers and radiologists are not statistically significantly different regarding their ability to identify lung cancer on CXRs, when supported by the fast track system. The fast-track system had a 59.4 % accuracy rate, detected by the number of imaging of reports that identified a serious pathology. This concludes that the system is performing well, yet could still be improved. IMPLICATIONS FOR PRACTICE: This audit provides further evidence for the value of developing and deploying reporting radiographers for projection radiography reporting.


Asunto(s)
Neoplasias Pulmonares , Radiografía Torácica , Radiólogos , Derivación y Consulta , Tomografía Computarizada por Rayos X , Humanos , Neoplasias Pulmonares/diagnóstico por imagen , Radiografía Torácica/normas , Radiólogos/normas , Tomografía Computarizada por Rayos X/normas , Medicina Estatal , Femenino , Masculino , Reino Unido , Competencia Clínica , Anciano , Persona de Mediana Edad , Inglaterra
5.
Radiat Prot Dosimetry ; 200(7): 700-706, 2024 May 08.
Artículo en Inglés | MEDLINE | ID: mdl-38555500

RESUMEN

In this study, an evaluation of the compliance test data from 684 computed tomography (CT)-scanners in Indonesia for the 2019-22 test period was carried out. The study was aimed to describe the performance profile of CT-scanners in Indonesia and evaluate the testing protocol. A total of 87.8% of the CT-scanners unconditionally passed the tests, 8.8% passed the tests with conditions and 3.4% failed the tests. Of the devices conditionally passed the tests, the top two causes were water CT number accuracy (45.2%) and laser position accuracy (41.9%). Meanwhile, 75.0% of the failed devices were due to failing to meet the patient dose test criteria. The failure of the test for the water CT number accuracy parameter was caused by variations in the type of phantom used in the test, where several types of phantoms did not use water as material of the homogeneity module. Failures in laser position accuracy test were caused by the passing criteria that adjust to the minimum slice thickness, so that modern CT-scanner with small detector sizes and collimations tend not to pass. On the other hand, the failure on dose aspects was due to the frequent unavailability of baseline values for comparison. Of these top three failure causes, two of them, namely the CT number and dose test parameters, have been accommodated in the latest regulation (BAPETEN Regulation No. 2/2022) with a change in the evaluation method, while for the laser position accuracy test it is recommended to alter the passing criteria to an absolute value, namely 1 mm.


Asunto(s)
Fantasmas de Imagen , Dosis de Radiación , Tomógrafos Computarizados por Rayos X , Indonesia , Humanos , Tomógrafos Computarizados por Rayos X/normas , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
6.
Eur J Radiol ; 175: 111429, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38508091

RESUMEN

The escalating use of Computed Tomography (CT) imaging necessitates establishment and periodic revision of Diagnostic Reference Levels (DRLs) to ensure patient protection optimization. This paper presents the outcomes of a national survey conducted from 2019 to 2022, focusing on revising DRLs for adult CT examinations. Dosimetric data from 127 scanners in 120 medical facilities, representing 25% of the country's CT scanners, were collected, emphasizing geographic distribution and technology representation. Τhe parameters used for DRLs were the CTDIvol and the DLP of a typical acquisition of the region of interest (scan DLP). In addition to the 7 CT examination for which the DRL values were revised, establishment of DRLs for neck, cervical spine, pelvic bones-hips, coronary artery calcium (Ca) score and cardiac computed tomography angiography (CCTA) examinations was performed. Revised DRLs exhibited a 15 % average decrease in CTDIvol and a 7 % average decrease in scan DLP from the initial DRLs. This reduction of dosimetric values is relatively low compared to other national studies. The findings revealed wide variations in dosimetric values and scan lengths among scanners, emphasizing the need for standardization and optimization. Incorporation of advanced technologies like Iterative Reconstruction (IR) showcased potential for further dose reduction, yet challenges in uniform implementation persist. The study underscores the importance of ongoing optimisation efforts, particularly in the context of increased CT utilization and evolving technology. The revised DRLs have been officially adopted in Greece, emphasizing the commitment to safe and effective CT practices.


Asunto(s)
Niveles de Referencia para Diagnóstico , Dosis de Radiación , Protección Radiológica , Tomografía Computarizada por Rayos X , Humanos , Tomografía Computarizada por Rayos X/normas , Tomografía Computarizada por Rayos X/métodos , Grecia , Protección Radiológica/normas , Protección Radiológica/métodos , Adulto
7.
Childs Nerv Syst ; 40(6): 1873-1879, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38393384

RESUMEN

BACKGROUND: Intracranial volume (ICV) is an important indicator of the development of the brain and skull in children. At present, there is a lack of ICV growth standards based on large infant and children samples. Our aim was to assess the normal range of the ICV variation in Russian children using a modern automatic system for constructing the endocranial cavity (Endex) and to provide growth standards of the ICV for clinical practice. METHODS: High-resolution head CT scans were obtained from 673 apparently healthy children (380 boys and 293 girls) aged 0-17 years and transformed into the ICV estimates using the Endex software. The open-source software RefCurv utilizing R and the GAMLSS add-on package with the LMS method was then used for the construction of smooth centile growth references for ICV according to age and sex. RESULTS: We demonstrated that the ICVs estimates calculated using the Endex software are perfectly comparable with those obtained by a conventional technique (i.e. seed feeling). Sex-specific pediatric growth charts for ICV were constructed. CONCLUSIONS: This study makes available for use in clinical practice ICV growth charts for the age from 0 to 17 based on a sample of 673 high-resolution CT images.


Asunto(s)
Encéfalo , Tomografía Computarizada por Rayos X , Humanos , Niño , Lactante , Preescolar , Masculino , Femenino , Adolescente , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Recién Nacido , Valores de Referencia , Encéfalo/diagnóstico por imagen , Encéfalo/crecimiento & desarrollo , Programas Informáticos , Cráneo/diagnóstico por imagen , Cráneo/anatomía & histología , Tamaño de los Órganos
8.
J Xray Sci Technol ; 32(3): 725-734, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38189739

RESUMEN

BACKGROUND: To reduce radiation dose and subsequent risks, several legislative documents in different countries describe the need for Diagnostic Reference Levels (DRLs). Spinal radiography is a common and high-dose examination. Therefore, the aim of this work was to establish the DRL for Computed Tomography (CT) examinations of the spine in healthcare institutions across Jordan. METHODS: Data was retrieved from the picture archiving and communications system (PACS), which included the CT Dose Index (CTDI (vol) ) and Dose Length Product (DLP). The median radiation dose values of the dosimetric indices were calculated for each site. DRL values were defined as the 75th percentile distribution of the median CTDI (vol)  and DLP values. RESULTS: Data was collected from 659 CT examinations (316 cervical spine and 343 lumbar-sacral spine). Of the participants, 68% were males, and the patients' mean weight was 69.7 kg (minimum = 60; maximum = 80, SD = 8.9). The 75th percentile for the DLP of cervical and LS-spine CT scans in Jordan were 565.2 and 967.7 mGy.cm, respectively. CONCLUSIONS: This research demonstrates a wide range of variability in CTDI (vol)  and DLP values for spinal CT examinations; these variations were associated with the acquisition protocol and highlight the need to optimize radiation dose in spinal CT examinations.


Asunto(s)
Dosis de Radiación , Columna Vertebral , Tomografía Computarizada por Rayos X , Humanos , Jordania , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Masculino , Femenino , Adulto , Persona de Mediana Edad , Columna Vertebral/diagnóstico por imagen , Anciano , Benchmarking , Niveles de Referencia para Diagnóstico , Adolescente , Adulto Joven , Niño , Anciano de 80 o más Años
9.
Diagn Interv Imaging ; 104(7-8): 359-367, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37061392

RESUMEN

PURPOSE: The purpose of this study was to assess the performance of quantitative computed tomography (CT) imaging for detecting pancreatic fatty infiltration, using the results of histopathological analysis as reference. MATERIALS AND METHODS: Sixty patients who underwent pancreatic surgery for a pancreatic tumor between 2016 and 2019 were retrospectively included. There were 33 women and 27 men with a mean age of 56 ± 12 (SD) years (age range: 18-79 years). Patients with dilatation of the main pancreatic duct, chronic pancreatitis, or preoperative treatment were excluded to prevent any bias in the radiological-pathological correlation. Pancreatic fatty infiltration was recorded at pathology. Pancreatic surface lobularity, pancreatic attenuation, visceral fat area, and subcutaneous fat area were derived from preoperative CT images. The performance for the prediction of fatty infiltration was assessed using area under receiver operating characteristic curve (AUC) and backward binary logistic regression analysis. Results were validated in a separate cohort of 34 patients (17 women; mean age, 50 ± 14 [SD] years; age range: 18-73). RESULTS: A total of 28/60 (47%) and 17/34 (50%) patients had pancreatic fatty infiltration in the derivation and validation cohorts, respectively. In the derivation cohort, patients with pancreatic fatty infiltration had a significantly higher PSL (P < 0.001) and a lower pancreatic attenuation on both precontrast and portal venous phase images (P = 0.011 and 0.003, respectively), and higher subcutaneous fat area and visceral fat area (P = 0.010 and 0.007, respectively). Multivariable analysis identified pancreatic surface lobularity > 7.6 and pancreatic attenuation on portal venous phase images < 83.5 Hounsfield units as independently associated with fatty infiltration. The combination of these variables resulted in an AUC of 0.85 (95% CI: 0.74-0.95) and 0.83 (95% CI: 0.67-0.99) in the derivation and validation cohorts, respectively. CONCLUSION: CT-based quantitative imaging accurately predicts pancreatic fatty infiltration.


Asunto(s)
Fibrosis Quística , Lipomatosis , Páncreas , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/normas , Humanos , Masculino , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Área Bajo la Curva , Fibrosis Quística/diagnóstico por imagen , Lipomatosis/diagnóstico por imagen , Páncreas/diagnóstico por imagen , Neoplasias Pancreáticas/cirugía , Estándares de Referencia
10.
Phys Med Biol ; 68(6)2023 03 15.
Artículo en Inglés | MEDLINE | ID: mdl-36854190

RESUMEN

Objective. Low-dose computed tomography (LDCT) denoising is an important problem in CT research. Compared to the normal dose CT, LDCT images are subjected to severe noise and artifacts. Recently in many studies, vision transformers have shown superior feature representation ability over the convolutional neural networks (CNNs). However, unlike CNNs, the potential of vision transformers in LDCT denoising was little explored so far. Our paper aims to further explore the power of transformer for the LDCT denoising problem.Approach. In this paper, we propose a Convolution-free Token2Token Dilated Vision Transformer (CTformer) for LDCT denoising. The CTformer uses a more powerful token rearrangement to encompass local contextual information and thus avoids convolution. It also dilates and shifts feature maps to capture longer-range interaction. We interpret the CTformer by statically inspecting patterns of its internal attention maps and dynamically tracing the hierarchical attention flow with an explanatory graph. Furthermore, overlapped inference mechanism is employed to effectively eliminate the boundary artifacts that are common for encoder-decoder-based denoising models.Main results. Experimental results on Mayo dataset suggest that the CTformer outperforms the state-of-the-art denoising methods with a low computational overhead.Significance. The proposed model delivers excellent denoising performance on LDCT. Moreover, low computational cost and interpretability make the CTformer promising for clinical applications.


Asunto(s)
Redes Neurales de la Computación , Tomografía Computarizada por Rayos X , Artefactos , Procesamiento de Imagen Asistido por Computador/métodos , Relación Señal-Ruido , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Humanos
11.
J Comput Assist Tomogr ; 47(2): 199-204, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-36790871

RESUMEN

PURPOSE: Previous studies have pointed out that magnetic resonance- and fluorodeoxyglucose positron emission tomography-based radiomics had a high predictive value for the response of the neoadjuvant chemotherapy (NAC) in breast cancer by respectively characterizing tumor heterogeneity of the relaxation time and the glucose metabolism. However, it is unclear whether computed tomography (CT)-based radiomics based on density heterogeneity can predict the response of NAC. This study aimed to develop and validate a CT-based radiomics nomogram to predict the response of NAC in breast cancer. METHODS: A total of 162 breast cancer patients (110 in the training cohort and 52 in the validation cohort) who underwent CT scans before receiving NAC and had pathological response results were retrospectively enrolled. Grades 4 to 5 cases were classified as response to NAC. According to the Miller-Payne grading system, grades 1 to 3 cases were classified as nonresponse to NAC. Radiomics features were extracted, and the optimal radiomics features were obtained to construct a radiomics signature. Multivariate logistic regression was used to develop the clinical prediction model and the radiomics nomogram that incorporated clinical characteristics and radiomics score. We assessed the performance of different models, including calibration and clinical usefulness. RESULTS: Eight optimal radiomics features were obtained. Human epidermal growth factor receptor 2 status and molecular subtype showed statistical differences between the response group and the nonresponse group. The radiomics nomogram had more favorable predictive efficacy than the clinical prediction model (areas under the curve, 0.82 vs 0.70 in the training cohort; 0.79 vs 0.71 in the validation cohort). The Delong test showed that there are statistical differences between the clinical prediction model and the radiomics nomogram ( z = 2.811, P = 0.005 in the training cohort). The decision curve analysis showed that the radiomics nomogram had higher overall net benefit than the clinical prediction model. CONCLUSION: The radiomics nomogram based on CT radiomics signature and clinical characteristics has favorable predictive efficacy for the response of NAC in breast cancer.


Asunto(s)
Neoplasias de la Mama , Biología Computacional , Tomografía Computarizada por Rayos X , Biología Computacional/normas , Tomografía Computarizada por Rayos X/normas , Terapia Neoadyuvante , Neoplasias de la Mama/diagnóstico por imagen , Neoplasias de la Mama/tratamiento farmacológico , Valor Predictivo de las Pruebas , Estudios Retrospectivos , Modelos Estadísticos , Humanos , Femenino , Adulto , Persona de Mediana Edad , Reproducibilidad de los Resultados
12.
Eur J Radiol ; 161: 110734, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36842273

RESUMEN

PURPOSE: To compare liver fat quantification between MRI and photon-counting CT (PCCT). METHOD: A cylindrical phantom with inserts containing six concentrations of oil (0, 10, 20, 30, 50 and 100%) and oil-iodine mixtures (0, 10, 20, 30 and 50% fat +3 mg/mL iodine) was imaged with a PCCT (NAEOTOM Alpha) and a 1.5 T MRI system (MR 450w, IDEAL-IQ sequence), using clinical parameters. An IRB-approved prospective clinical evaluation included 12 obese adult patients with known fatty liver disease (seven women, mean age: 61.5 ± 13 years, mean BMI: 30.3 ± 4.7 kg/m2). Patients underwent a same-day clinical MRI and PCCT of the abdomen. Liver fat fractions were calculated for four segments (I, II, IVa and VII) using in- and opposed-phase on MRI ((Meanin - Meanopp)/2*Meanin) and iodine-fat, tissue decomposition analysis in PCCT (Syngo.Via VB60A). CT and MRI Fat fractions were compared using two-sample t-tests with equal variance. Statistical analysis was performed using RStudio (Version1.4.1717). RESULTS: Phantom results showed no significant differences between the known fat fractions (P = 0.32) or iodine (P = 0.6) in comparison to PCCT-measured concentrations, and no statistically significant difference between known and MRI-measured fat fractions (P = 0.363). In patients, the mean fat signal fraction measured on MRI and PCCT was 13.1 ± 9.9% and 12.0 ± 9.0%, respectively, with an average difference of 1.1 ± 1.9% between the modalities (P = 0.138). CONCLUSION: First experience shows promising accuracy of liver fat fraction quantification for PCCT in obese patients. This method may improve opportunistic screening for CT in the future.


Asunto(s)
Tejido Adiposo , Hígado , Imagen por Resonancia Magnética , Tomografía Computarizada por Rayos X , Tomografía Computarizada por Rayos X/normas , Imagen por Resonancia Magnética/normas , Humanos , Masculino , Femenino , Persona de Mediana Edad , Anciano , Hígado/diagnóstico por imagen , Tejido Adiposo/diagnóstico por imagen , Hígado Graso/diagnóstico por imagen , Reproducibilidad de los Resultados
13.
IEEE Trans Med Imaging ; 42(4): 1210-1224, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36449587

RESUMEN

Photoacoustic computed tomography (PACT) images optical absorption contrast by detecting ultrasonic waves induced by optical energy deposition in materials such as biological tissues. An ultrasonic transducer array or its scanning equivalent is used to detect ultrasonic waves. The spatial distribution of the transducer elements must satisfy the spatial Nyquist criterion; otherwise, spatial aliasing occurs and causes artifacts in reconstructed images. The spatial Nyquist criterion poses different requirements on the transducer elements' distributions for different locations in the image domain, which has not been studied previously. In this research, we elaborate on the location dependency through spatiotemporal analysis and propose a location-dependent spatiotemporal antialiasing method. By applying this method to PACT in full-ring array geometry, we effectively mitigate aliasing artifacts with minimal effects on image resolution in both numerical simulations and in vivo experiments.


Asunto(s)
Técnicas Fotoacústicas , Tomografía Computarizada por Rayos X , Artefactos , Análisis Espacio-Temporal , Tomografía Computarizada por Rayos X/instrumentación , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Mama/diagnóstico por imagen , Humanos , Procesamiento de Imagen Asistido por Computador , Algoritmos , Técnicas Fotoacústicas/métodos , Técnicas Fotoacústicas/normas , Simulación por Computador , Fantasmas de Imagen , Femenino , Reproducibilidad de los Resultados
14.
Ethiop J Health Sci ; 33(6): 1005-1014, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38784484

RESUMEN

Background: X-ray Computed Tomography dose levels have been varying among modalities and scanning body regions due to the absence of incessant routine follow-up. Thus, the study aimed to compute the dose index discrepancies in Ethiopia for the most recurring scan protocols (head, chest, abdomen, and pelvis). Methods: A purposive sampling method was employed to select the hospitals due to the rare existence of functional CT scanners in Ethiopia. From the selected hospitals, a total of 1,385 (249 heads, 804 chests, 132 abdomens, and 200 pelvis) were collected in terms of standard dose metric values in the period of December 2019-March 2020. Patients' DLP was computed into mean value using IBM SPSS Statistics 20 software. From the mean DLP, we can compute the effective dose. Results: Patients' dose level disparity was observed in this study though it is below the ICRP standard level for all body regions except for pelvis DLP (593.37 mGy-cm) at Black Lion. The dose level for the head and chest are computed within the recommended level at all hospitals. Effective doses for the pelvis at four hospitals (Teklehaimanot, Black Lion, ALERT, Paul's, and Ayder hospitals) were computed as 6.45, 8.90, 5.08, 6.54, and 6.84 mSv respectively, and the effective doses for abdomen at Ayder Hospital was obtained to be 8.90 mSv, which is above the recommended value. Conclusion: X-ray CT scanners are somewhat properly functioning although some sort of justification and optimization for pelvis and abdomen examinations are strongly recommended to implement as low as reasonably achievable principle.


Asunto(s)
Hospitales , Pelvis , Dosis de Radiación , Tomografía Computarizada por Rayos X , Humanos , Etiopía , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/estadística & datos numéricos , Tomografía Computarizada por Rayos X/normas , Pelvis/diagnóstico por imagen , Cabeza/diagnóstico por imagen , Femenino , Abdomen/diagnóstico por imagen , Masculino , Tórax/diagnóstico por imagen
15.
Sci Rep ; 12(1): 1716, 2022 02 02.
Artículo en Inglés | MEDLINE | ID: mdl-35110593

RESUMEN

The rapid evolution of the novel coronavirus disease (COVID-19) pandemic has resulted in an urgent need for effective clinical tools to reduce transmission and manage severe illness. Numerous teams are quickly developing artificial intelligence approaches to these problems, including using deep learning to predict COVID-19 diagnosis and prognosis from chest computed tomography (CT) imaging data. In this work, we assess the value of aggregated chest CT data for COVID-19 prognosis compared to clinical metadata alone. We develop a novel patient-level algorithm to aggregate the chest CT volume into a 2D representation that can be easily integrated with clinical metadata to distinguish COVID-19 pneumonia from chest CT volumes from healthy participants and participants with other viral pneumonia. Furthermore, we present a multitask model for joint segmentation of different classes of pulmonary lesions present in COVID-19 infected lungs that can outperform individual segmentation models for each task. We directly compare this multitask segmentation approach to combining feature-agnostic volumetric CT classification feature maps with clinical metadata for predicting mortality. We show that the combination of features derived from the chest CT volumes improve the AUC performance to 0.80 from the 0.52 obtained by using patients' clinical data alone. These approaches enable the automated extraction of clinically relevant features from chest CT volumes for risk stratification of COVID-19 patients.


Asunto(s)
COVID-19/diagnóstico , COVID-19/virología , Aprendizaje Profundo , SARS-CoV-2 , Tórax/diagnóstico por imagen , Tórax/patología , Tomografía Computarizada por Rayos X , Algoritmos , COVID-19/mortalidad , Bases de Datos Genéticas , Humanos , Interpretación de Imagen Asistida por Computador/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Pronóstico , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas
16.
Technol Cancer Res Treat ; 21: 15330338221074498, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35099325

RESUMEN

Object: By retrospectively analyzing the energy spectrum of squamous cell carcinoma, adenocarcinoma, small cell lung cancer (SCLC), and pulmonary metastases that underwent dual-layer detector spectral computed tomography (DLCT) 3-phase scan of the chest, we explored the value of a multiparameter energy spectrum in the assessment of pathological types of lung tumors. Methods: Cases of squamous cell carcinoma (n = 20), adenocarcinoma (n = 24), SCLC (n = 26), and metastases (n = 14) were collected. Then the largest cross-sectional area (LCA) of the lesion, computed tomography (CT) values in the plain scan phase, arterial and venous phases (HU, HUa, and HUv), iodine concentration, and effective atomic number in the arterial and venous phases (ICa, ICv, Zeff[a], and Zeff[v]) were measured and compared among the nonsmall cell lung cancer (NSCLC), SCLC and metastases, and other 3 groups of SCLC, squamous cell carcinoma, and adenocarcinoma. Results: Only the LCA is statistically different among SCLC, NSCLC, and metastases (P < .05). And the treated subgroup analysis did not show significant differences among the groups. However, the untreated subgroup analysis showed that there was a significant difference between NSCLC and metastases in LCA, SCLC and metastases in ICa, NSCLC and SCLC in HUv, NSCLC and SCLC in Zeff(v) (P < .05). Conclusion: The energy spectrum parameters of DLCT have a certain clinical value in distinguishing NSCLC from SCLC in the Zeff(v) and distinguishing SCLC from metastases in the ICa.


Asunto(s)
Neoplasias Pulmonares/diagnóstico por imagen , Neoplasias Pulmonares/patología , Tomografía Computarizada por Rayos X/métodos , Anciano , Toma de Decisiones Clínicas , Diagnóstico Diferencial , Manejo de la Enfermedad , Femenino , Humanos , Procesamiento de Imagen Asistido por Computador , Masculino , Persona de Mediana Edad , Estadificación de Neoplasias , Estudios Retrospectivos , Tomografía Computarizada por Rayos X/normas
17.
Curr Med Sci ; 42(1): 217-225, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-35089491

RESUMEN

OBJECTIVE: The objective of this study was to investigate the application of unenhanced computed tomography (CT) texture analysis in differentiating pancreatic adenosquamous carcinoma (PASC) from pancreatic ductal adenocarcinoma (PDAC). METHODS: Preoperative CT images of 112 patients (31 with PASC, 81 with PDAC) were retrospectively reviewed. A total of 396 texture parameters were extracted from AnalysisKit software for further texture analysis. Texture features were selected for the differentiation of PASC and PDAC by the Mann-Whitney U test, univariate logistic regression analysis, and the minimum redundancy maximum relevance algorithm. Furthermore, receiver operating characteristic (ROC) curve analysis was performed to evaluate the diagnostic performance of the texture feature-based model by the random forest (RF) method. Finally, the robustness and reproducibility of the predictive model were assessed by the 10-times leave-group-out cross-validation (LGOCV) method. RESULTS: In the present study, 10 texture features to differentiate PASC from PDAC were eventually retained for RF model construction after feature selection. The predictive model had a good classification performance in differentiating PASC from PDAC, with the following characteristics: sensitivity, 95.7%; specificity, 92.5%; accuracy, 94.3%; positive predictive value (PPV), 94.3%; negative predictive value (NPV), 94.3%; and area under the ROC curve (AUC), 0.98. Moreover, the predictive model was proved to be robust and reproducible using the 10-times LGOCV algorithm (sensitivity, 90.0%; specificity, 71.3%; accuracy, 76.8%; PPV, 59.0%; NPV, 95.2%; and AUC, 0.80). CONCLUSION: The unenhanced CT texture analysis has great potential for differentiating PASC from PDAC.


Asunto(s)
Carcinoma Adenoescamoso/diagnóstico por imagen , Carcinoma Ductal Pancreático/diagnóstico por imagen , Neoplasias Pancreáticas/diagnóstico por imagen , Tomografía Computarizada por Rayos X/normas , Adulto , Anciano , Diagnóstico Diferencial , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valor Predictivo de las Pruebas , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/métodos , Neoplasias Pancreáticas
18.
Am J Emerg Med ; 52: 225-231, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34971907

RESUMEN

INTRODUCTION: Computed tomography (CT) is a commonly used imaging modality in Emergency Departments (EDs), however its use is questionable in many low yield settings. The Emergency CT Head score (ECHS) is a recently published clinical tool that assists in stratifying the need for CT brain (CTB) for patients presenting without a history of trauma. We sought to validate this tool in an Australian ED setting. METHODS: We prospectively evaluated 412 patients who received CTB without a history of trauma at a large Australian ED. We assessed them for the 4 main ECHS data points: focal neurological deficit on physical examination, new acute onset headache, transient neurological deficit, and a combination of new onset seizures with an altered conscious state. We examined their association with acute and chronic CTB findings. We then applied the ECHS to our data, calculating its sensitivity and its appropriateness at this single site via the calculation of a receiver operating curve (ROC). RESULTS: 10.2% of all CTB performed were positive for an acute or chronic abnormality. Only sex (male) and focal motor deficit were independent predictors of positive CTB at univariate analysis. The ECHS did not perform as anticipated in our population, with a ROC area under the curve of 0.498. An ECHS score of >0, which has been proposed as the threshold to not require imaging, had sensitivity of only 83.3% in our population. CONCLUSIONS: Further research and validation is required in order to safely implement the ECHS clinical score in the Australian ED setting.


Asunto(s)
Servicio de Urgencia en Hospital/organización & administración , Tomografía Computarizada por Rayos X/normas , Anciano , Anciano de 80 o más Años , Australia , Traumatismos Craneocerebrales/diagnóstico , Técnicas de Apoyo para la Decisión , Servicio de Urgencia en Hospital/estadística & datos numéricos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Curva ROC
19.
Acta Radiol ; 63(3): 336-344, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33663246

RESUMEN

BACKGROUND: This study examined whether ultra-low-dose chest computed tomography (ULD-CT) could improve detection of acute chest conditions. PURPOSE: To determine (i) whether diagnostic accuracy of ULD-CT is superior to supine chest X-ray (sCXR) for acute chest conditions and (ii) the feasibility of ULD-CT in an emergency department. MATERIAL AND METHODS: From 1 February to 31 July 2019, 91 non-traumatic patients from the Emergency Department were prospectively enrolled in the study if they received an sCXR. An ULD-CT and a non-contrast chest CT (NCCT) scan were then performed. Three radiologists assessed the sCXR and ULD-CT examinations for cardiogenic pulmonary edema, pneumonia, pneumothorax, and pleural effusion. Resources and effort were compared for sCXR and ULD-CT to evaluate feasibility. Diagnostic accuracy was calculated for sCXR and ULD-CT using NCCT as the reference standard. RESULTS: The mean effective dose of ULD-CT was 0.05±0.01 mSv. For pleural effusion and cardiogenic pulmonary edema, no difference in diagnostic accuracy between ULD-CT and sCXR was observed. For pneumonia and pneumothorax, sensitivities were 100% (95% confidence interval [CI] 69-100) and 50% (95% CI 7-93) for ULD-CT and 60% (95% CI 26-88) and 0% (95% CI 0-0) for sCXR, respectively. Median examination time was 10 min for ULD-CT vs. 5 min for sCXR (P<0.001). For ULD-CT 1-2 more staff members were needed compared to sCXR (P<0.001). ULD-CT was rated more challenging to perform than sCXR (P<0.001). CONCLUSION: ULD-CT seems equal or better in detecting acute chest conditions compared to sCXR. However, ULD-CT examinations demand more effort and resources.


Asunto(s)
Servicio de Urgencia en Hospital , Dosis de Radiación , Radiografía Torácica/métodos , Tomografía Computarizada por Rayos X/métodos , Anciano , Intervalos de Confianza , Estudios de Factibilidad , Femenino , Humanos , Masculino , Derrame Pleural/diagnóstico por imagen , Neumonía/diagnóstico por imagen , Neumotórax/diagnóstico por imagen , Estudios Prospectivos , Edema Pulmonar/diagnóstico por imagen , Exposición a la Radiación , Radiografía Torácica/normas , Estándares de Referencia , Sensibilidad y Especificidad , Tomografía Computarizada por Rayos X/normas
20.
J Trauma Acute Care Surg ; 92(1): 44-48, 2022 01 01.
Artículo en Inglés | MEDLINE | ID: mdl-34932040

RESUMEN

BACKGROUND: Ultrasonography for trauma is a widely used tool in the initial evaluation of trauma patients with complete ultrasonography of trauma (CUST) demonstrating equivalence to computed tomography (CT) for detecting clinically significant abdominal hemorrhage. Initial reports demonstrated high sensitivity of CUST for the bedside diagnosis of pneumothorax. We hypothesized that the sensitivity of CUST would be greater than initial supine chest radiograph (CXR) for detecting pneumothorax. METHODS: A retrospective analysis of patients diagnosed with pneumothorax from 2018 through 2020 at a Level I trauma center was performed. Patients included had routine supine CXR and CUST performed prior to intervention as well as confirmatory CT imaging. All CUST were performed during the initial evaluation in the trauma bay by a registered sonographer. All imaging was evaluated by an attending radiologist. Subgroup analysis was performed after excluding occult pneumothorax. Immediate tube thoracostomy was defined as tube placement with confirmatory CXR within 8 hours of admission. RESULTS: There were 568 patients screened with a diagnosis of pneumothorax, identifying 362 patients with a confirmed pneumothorax in addition to CXR, CUST, and confirmatory CT imaging. The population was 83% male, had a mean age of 45 years, with 85% presenting due to blunt trauma. Sensitivity of CXR for detecting pneumothorax was 43%, while the sensitivity of CUST was 35%. After removal of occult pneumothorax (n = 171), CXR was 78% sensitive, while CUST was 65% sensitive (p < 0.01). In this subgroup, CUST had a false-negative rate of 36% (n = 62). Of those patients with a false-negative CUST, 50% (n = 31) underwent tube thoracostomy, with 85% requiring immediate placement. CONCLUSION: Complete ultrasonography of trauma performed on initial trauma evaluation had lower sensitivity than CXR for identification of pneumothorax including clinically significant pneumothorax requiring tube thoracostomy. Using CUST as the primary imaging modality in the initial evaluation of chest trauma should be considered with caution. LEVEL OF EVIDENCE: Diagnostic Test study, Level IV.


Asunto(s)
Neumotórax , Traumatismos Torácicos , Toracostomía , Tomografía Computarizada por Rayos X , Ultrasonografía , Errores Diagnósticos/prevención & control , Errores Diagnósticos/estadística & datos numéricos , Reacciones Falso Negativas , Femenino , Humanos , Masculino , Tamizaje Masivo/métodos , Persona de Mediana Edad , Posicionamiento del Paciente/métodos , Neumotórax/diagnóstico por imagen , Neumotórax/etiología , Radiografía Torácica/métodos , Radiografía Torácica/normas , Sensibilidad y Especificidad , Traumatismos Torácicos/complicaciones , Traumatismos Torácicos/diagnóstico , Traumatismos Torácicos/epidemiología , Toracostomía/instrumentación , Toracostomía/métodos , Toracostomía/estadística & datos numéricos , Tiempo de Tratamiento , Tomografía Computarizada por Rayos X/métodos , Tomografía Computarizada por Rayos X/normas , Centros Traumatológicos/estadística & datos numéricos , Ultrasonografía/métodos , Ultrasonografía/normas , Estados Unidos/epidemiología , Heridas no Penetrantes/complicaciones , Heridas no Penetrantes/diagnóstico , Heridas no Penetrantes/epidemiología
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA