Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.326
Filtrar
1.
Artículo en Inglés | MEDLINE | ID: mdl-39088505

RESUMEN

Transcutaneous spinal stimulation (TSS) is a promising rehabilitative intervention to restore motor function and coordination for individuals with spinal cord injury (SCI). The effects of TSS are most commonly assessed by evaluating muscle response to stimulation using surface electromyography (sEMG). Given the increasing use of robotic devices to deliver therapy and the emerging potential of hybrid rehabilitation interventions that combine neuromodulation with robotic devices, there is an opportunity to leverage the on-board sensors of the robots to measure kinematic and torque changes of joints in the presence of stimulation. This paper explores the potential for robotic assessment of the effects of TSS delivered to the cervical spinal cord. We used a four degree-of-freedom exoskeleton to measure the torque response of upper limb (UL) joints during stimulation, while simultaneously recording sEMG. We analyzed joint torque and electromyography data generated during TSS delivered over individual sites of the cervical spinal cord in neurologically intact participants. We show that site-specific effects of TSS are manifested not only by modulation of the amplitude of spinally evoked motor potentials in UL muscles, but also by changes in torque generated by individual UL joints. We observed preferential resultant action of proximal muscles and joints with stimulation at the rostral site, and of proximal joints with rostral-lateral stimulation. Robotic assessment can be used to measure the effects of TSS, and could be integrated into complex control algorithms that govern the behavior of hybrid neuromodulation-robotic systems.


Asunto(s)
Electromiografía , Dispositivo Exoesqueleto , Robótica , Traumatismos de la Médula Espinal , Torque , Extremidad Superior , Humanos , Robótica/instrumentación , Masculino , Adulto , Traumatismos de la Médula Espinal/rehabilitación , Femenino , Fenómenos Biomecánicos , Músculo Esquelético/fisiología , Médula Cervical , Voluntarios Sanos , Estimulación de la Médula Espinal/instrumentación , Estimulación de la Médula Espinal/métodos , Adulto Joven , Estimulación Eléctrica Transcutánea del Nervio/instrumentación , Estimulación Eléctrica Transcutánea del Nervio/métodos , Vértebras Cervicales , Algoritmos
2.
Sci Rep ; 14(1): 18589, 2024 08 10.
Artículo en Inglés | MEDLINE | ID: mdl-39127797

RESUMEN

We aimed to assess high-density surface electromyography (HDsEMG)-torque relationships in the presence of delayed onset trunk muscle soreness (DOMS) and the effect of these relationships on torque steadiness (TS) and lumbar movement during concentric/eccentric submaximal trunk extension contractions. Twenty healthy individuals attended three laboratory sessions (24 h apart). HDsEMG signals were recorded unilaterally from the thoracolumbar erector spinae with two 64-electrode grids. HDsEMG-torque signal relationships were explored via coherence (0-5 Hz) and cross-correlation analyses. Principal component analysis was used for HDsEMG-data dimensionality reduction and improvement of HDsEMG-torque-based estimations. DOMS did not reduce either concentric or eccentric trunk extensor muscle strength. However, in the presence of DOMS, improved TS, alongside an altered HDsEMG-torque relationship and kinematic changes were observed, in a contraction-dependent manner. For eccentric trunk extension, improved TS was observed, with greater lumbar flexion movement and a reduction in δ-band HDsEMG-torque coherence and cross-correlation. For concentric trunk extensions, TS improvements were observed alongside reduced thoracolumbar sagittal movement. DOMS does not seem to impair the ability to control trunk muscle force, however, perceived soreness induced changes in lumbar movement and muscle recruitment strategies, which could alter motor performance if the exposure to pain is maintained in the long term.


Asunto(s)
Electromiografía , Ejercicio Físico , Mialgia , Humanos , Masculino , Mialgia/fisiopatología , Mialgia/etiología , Adulto , Femenino , Ejercicio Físico/fisiología , Fenómenos Biomecánicos , Torque , Adulto Joven , Contracción Muscular/fisiología , Músculo Esquelético/fisiopatología , Músculo Esquelético/fisiología , Región Lumbosacra/fisiopatología , Torso/fisiopatología , Vértebras Lumbares/fisiopatología
3.
Sci Rep ; 14(1): 17959, 2024 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-39095422

RESUMEN

Shoes affect the evolved biomechanics of the foot, potentially affecting running kinematics and kinetics that can in turn influence injury and performance. An important feature of conventional running shoes is heel height, whose effects on foot and ankle biomechanics remain understudied. Here, we investigate the effects of 6-26 mm increases in heel height on ankle dynamics in 8 rearfoot strike runners who ran barefoot and in minimal shoes with added heels. We predicted higher heels would lead to greater frontal plane ankle torques due to the increased vertical moment arm of the mediolateral ground reaction force. Surprisingly, the torque increased in minimal shoes with no heel elevation, but then decreased with further increases in heel height due to changes in foot posture. We also found that increasing heel height caused a large increase in the ankle plantarflexion velocity at heel strike, which we explain using a passive collision model. Our results highlight how running in minimal shoes may be significantly different from barefoot running due to complex interactions between proprioception and biomechanics that also permit runners to compensate for modifications to shoe design, more in the frontal than sagittal planes.


Asunto(s)
Tobillo , Talón , Carrera , Zapatos , Carrera/fisiología , Humanos , Fenómenos Biomecánicos , Masculino , Talón/fisiología , Adulto , Tobillo/fisiología , Femenino , Articulación del Tobillo/fisiología , Adulto Joven , Pie/fisiología , Torque , Marcha/fisiología
4.
BMC Oral Health ; 24(1): 921, 2024 Aug 09.
Artículo en Inglés | MEDLINE | ID: mdl-39123145

RESUMEN

OBJECTIVE: To evaluate the effects of different attachment configurations with and without buccal root torque on expansion movements achieved with aligners through finite element analysis (FEA). METHODS: FEA modelling was done with 0.25 mm buccal expansion force application to the maxillary molars with different attachment configurations: Eight models were tested (1) no attachment (NA), (2) horizontal attachment (HA), (3) gingivally beveled horizontal attachment (GHA), and (4) occlusally beveled horizontal attachment (OHA), as well as models with 6obuccal root torque, (5) no attachment (TNA), (6) horizontal attachment (THA), (7) gingivally beveled horizontal attachment (TGHA), and (8) occlusally beveled horizontal attachment (TOHA). RESULTS: The first and second molars exhibited buccal tipping in all models. The highest amount of buccal tipping for the molars was observed in the NA (6CMB, 0.232 mm; 6CMP, 0.246 mm; 7CMB, 0.281 mm; 7CMP, 0.312 mm) and GHA (6CMB, 0.230; 6CMP, 0.245; 7CMB, 0.279 mm; 7CMP, 0.311 mm) models, respectively, while the least tipping was observed in the TOHA model (6CMB, 0.155 mm; 6CMP, 0.168 mm; 7CMB, 0.216 mm; 7CMP, 0.240 mm). In all groups, the buccal tipping of the second molars was higher than that of the first molars. CONCLUSION: This FEA study showed that expansion with aligners tip maxillary molars buccally and the use of occlusally beveled attachments and addition of buccal root torque reduces uncontrolled buccal tipping.


Asunto(s)
Análisis de Elementos Finitos , Maxilar , Diente Molar , Técnica de Expansión Palatina , Humanos , Técnica de Expansión Palatina/instrumentación , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Torque , Diseño de Aparato Ortodóncico , Raíz del Diente , Fenómenos Biomecánicos , Análisis del Estrés Dental , Simulación por Computador
5.
Andes Pediatr ; 95(3): 252-262, 2024 Jun.
Artículo en Español | MEDLINE | ID: mdl-39093210

RESUMEN

The measurement of isometric muscle torque with hand-held dynamometry is a technique little studied in the pediatric setting for the evaluation of maximal isometric muscle strength. OBJECTIVE: to determine the reliability of hand-held dynamometry to obtain the maximal isometric torque of upper and lower limb muscle groups in Chilean children and adolescents. PATIENTS AND METHODS: Crosssectional study. Seventy-two participants aged between 7 and 15 years were selected from a school in Talca. Maximal isometric torque was recorded in 15 muscle groups of upper and lower limbs through hand-held dynamometry. Intra- and inter-rater evaluation was used, applying the intraclass correlation coefficient (ICC) to determine the reliability of the tests and Bland-Altman plots to evaluate concordance. RESULTS: The results demonstrated good to excellent inter-rater reliability (ICC = 0.850.98) and intra-rater reliability (ICC = 0.87-0.98). Only two groups, hip extensors and abductors, showed good inter-rater reliability (ICC = 0.85 and ICC = 0.88, respectively); and one group, the ankle dorsiflexors, showed good intra-rater reliability (ICC = 0.87). 100% of the tests presented at least 95.8% inter- and intra-rater agreement on the Bland-Altman plots. CONCLUSION: The evaluation of isometric muscle torque using hand-held dynamometry is a reliable procedure for use in different growth periods.


Asunto(s)
Contracción Isométrica , Dinamómetro de Fuerza Muscular , Fuerza Muscular , Torque , Humanos , Niño , Adolescente , Reproducibilidad de los Resultados , Masculino , Femenino , Estudios Transversales , Chile , Contracción Isométrica/fisiología , Fuerza Muscular/fisiología , Músculo Esquelético/fisiología , Variaciones Dependientes del Observador , Extremidad Inferior/fisiología
6.
BMC Musculoskelet Disord ; 25(1): 516, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38970034

RESUMEN

BACKGROUND: Sacral screw loosening is a typical complication after internal fixation surgery through the vertebral arch system. Bicortical fixation can successfully prevent screw loosening, and how improving the rate of bicortical fixation is a challenging clinical investigation. OBJECTIVE: To investigate the feasibility of improving the double corticality of sacral screws and the optimal fixation depth to achieve double cortical fixation by combining the torque measurement method with bare hands. METHODS: Ninety-seven cases of posterior lumbar internal fixation with pedicle root system were included in this study. Based on the tactile feedback of the surgeon indicating the expected penetration of the screw into the contralateral cortex of the sacrum, the screws were further rotated by 180°, 360°, or 720°, categorized into the bicortical 180° group, bicortical 360° group, and bicortical 720° group, respectively. Intraoperatively, the torque during screw insertion was recorded. Postoperatively, the rate of double-cortex engagement was evaluated at 7 days, and screw loosening was assessed at 1 year follow-up. RESULTS: The bicortical rates of the 180° group, 360° group, and 720° group were 66.13%, 91.18% and 93.75%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05).The rates of loosening of sacral screws in the 180° group, 360° group, and 720° group were 20.97%, 7.35% and 7.81%, respectively. There were statistically significant differences between the 180° group and both the 360° and 720° groups (P < 0.05). However, there was no statistically significant difference between the 360° group and the 720° group (P > 0.05). The bicortical 360° group achieved a relatively satisfactory rate of dual cortical purchase while maintaining a lower rate of screw loosening. CONCLUSION: Manual insertion of sacral screws with the assistance of a torque measurement device can achieve a relatively satisfactory dual cortical purchase rate while reducing patient hospitalization costs.


Asunto(s)
Tornillos Óseos , Vértebras Lumbares , Sacro , Fusión Vertebral , Torque , Humanos , Masculino , Femenino , Sacro/cirugía , Sacro/diagnóstico por imagen , Persona de Mediana Edad , Anciano , Fusión Vertebral/instrumentación , Fusión Vertebral/métodos , Fusión Vertebral/efectos adversos , Vértebras Lumbares/cirugía , Adulto , Estudios de Factibilidad , Resultado del Tratamiento , Estudios de Seguimiento
7.
Medicine (Baltimore) ; 103(27): e38742, 2024 Jul 05.
Artículo en Inglés | MEDLINE | ID: mdl-38968482

RESUMEN

In orthodontic treatment of patients during the mixed dentition period, arch expansion and opening deep overbite are one of the objectives to achieve proper alignment of the teeth and correction of sagittal and vertical discrepancies. However, the expected outcomes of most therapeutic regimens are not clear, making it impossible to standardize early treatment effects. Therefore, this study was designed to evaluate the impact of the Invisalign® First System on the dental arch circumference and incisor inclination in patients during the mixed dentition period. A total of 21 children during the mixed dentition period (10 females and 11 males, with an average age of 8.76 years) were included in this study. The patients received non-extraction treatment through Invisalign® First System clear aligners, and no other auxiliary devices were used except Invisalign® accessories. Subsequently, the cooperation degree of patients during treatment and the oral measurement parameters at the beginning (T1) and the end (T2) of treatment were collected. All patients showed moderate/good cooperation degree during treatment. Besides, horizontal width of the maxillary first molar increased significantly; the designed arch expansion was 4.1 mm (±1.4 mm), while the actual arch expansion was 3.0 mm (±1.7 mm). Furthermore, the torque expression rate of upper anterior teeth reached 56.53%. Invisalign® First System clear aligners can effectively correct the teeth of patients during the mixed dentition period, widen the circumference of dental arch, and control the torque of incisors.


Asunto(s)
Dentición Mixta , Incisivo , Maloclusión , Diente Molar , Torque , Humanos , Masculino , Femenino , Niño , Maloclusión/terapia , Aparatos Ortodóncicos Removibles , Arco Dental , Diseño de Aparato Ortodóncico , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos
8.
Nat Commun ; 15(1): 5756, 2024 Jul 09.
Artículo en Inglés | MEDLINE | ID: mdl-38982087

RESUMEN

The human body constantly experiences mechanical loading. However, quantifying internal loads within the musculoskeletal system remains challenging, especially during unconstrained dynamic activities. Conventional measures are constrained to laboratory settings, and existing wearable approaches lack muscle specificity or validation during dynamic movement. Here, we present a strategy for estimating corresponding joint torque from muscles with different architectures during various dynamic activities using wearable A-mode ultrasound. We first introduce a method to track changes in muscle thickness using single-element ultrasonic transducers. We then estimate elbow and knee torque with errors less than 7.6% and coefficients of determination (R2) greater than 0.92 during controlled isokinetic contractions. Finally, we demonstrate wearable joint torque estimation during dynamic real-world tasks, including weightlifting, cycling, and both treadmill and outdoor locomotion. The capability to assess joint torque during unconstrained real-world activities can provide new insights into muscle function and movement biomechanics, with potential applications in injury prevention and rehabilitation.


Asunto(s)
Músculo Esquelético , Torque , Ultrasonografía , Dispositivos Electrónicos Vestibles , Humanos , Masculino , Ultrasonografía/métodos , Ultrasonografía/instrumentación , Fenómenos Biomecánicos , Adulto , Músculo Esquelético/fisiología , Músculo Esquelético/diagnóstico por imagen , Adulto Joven , Articulación de la Rodilla/fisiología , Articulación de la Rodilla/diagnóstico por imagen , Articulación del Codo/fisiología , Articulación del Codo/diagnóstico por imagen , Femenino , Movimiento/fisiología , Articulaciones/fisiología , Articulaciones/diagnóstico por imagen , Contracción Muscular/fisiología
9.
PLoS One ; 19(7): e0307538, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-39028745

RESUMEN

This study explored the impact of landing height on the tibiofemoral joint's medial compartment force (MCF) during drop jumps to help athletes prevent knee injury. Experienced male participants (N = 16) performed drop jumps with landing heights from 0.15 m to 0.75 m. Kinematic/kinetic parameters were collected using a motion capture system and a three-dimensional force platform. The Med-Lat Knee model was used to calculate biomechanical indicators of the knee joint, and data were analyzed using one-way analysis of variance and one-dimensional statistical parametric mapping (SPM1d). Findings indicated that landing height significantly affected the anterior-posterior and vertical MCF, flexion-extension torque, internal-external rotation torque, and vertical ground reaction force (p<0.05)-all increasing with elevated landing height-and significantly impacted the generated force of the vastus medialis, vastus lateralis, and vastus intermedius (p<0.05). SPM1d analysis confirmed these results within specific time intervals. Thus, both the knee moment and the MCF exhibited similar coordinated changes during drop jumps, indicating that these may be adaptive movement strategy. The impact of varying drop jump heights on muscle groups around the knee joint varied suggests that different heights induce specific muscular responses and improve muscle coordination to prevent knee joint injuries.


Asunto(s)
Traumatismos de la Rodilla , Articulación Tibiofemoral , Torque , Humanos , Articulación Tibiofemoral/fisiología , Tibia/fisiología , Fémur/fisiología , Músculo Esquelético , Fenómenos Biomecánicos , Traumatismos de la Rodilla/prevención & control , Adulto
10.
BMC Oral Health ; 24(1): 797, 2024 Jul 15.
Artículo en Inglés | MEDLINE | ID: mdl-39009996

RESUMEN

BACKGROUND: Desirable molar distalization by bodily movement is challenging and can be difficult to achieve. This study investigated changes in molar angulation (mesiodistal tipping), molar inclination (buccolingual torque) and rotation during distalization using clear aligner therapy (CAT). MATERIALS AND METHODS: This retrospective study included 38 cone beam computed tomographic images (CBCTs) taken for patients treated with molar distalization using CAT. The study evaluated pre- (T0) and post-treatment (T1) CBCTs of 19 adult patients (36.68 ± 13.50 years) who underwent maxillary molar distalization using Invisalign® aligners (Align Technology, Inc., San José, CA, USA) with a minimum of 2 mm distalization. Changes in maxillary molar tip, torque and rotation were measured for 61 molars (183 roots). Paired t-test was used to evaluate the differences between pre- and post-treatment readings. The level of significance was set at p ≤ 0.05. The reproducibility of measurements was assessed by the intraclass correlation coefficient (ICC). RESULTS: Molar angulation did not show significant change after distalization (p = 0.158) however, there was significant increase in buccal molar inclination (p = 0.034) and mesiobuccal molar rotation (p < 0.001). CONCLUSION: Molar distalization of 2 mm did not cause significant molar tipping. Maxillary molars showed significant buccal inclination (increased torque) and mesiobuccal rotation after distalization.


Asunto(s)
Tomografía Computarizada de Haz Cónico , Maxilar , Diente Molar , Técnicas de Movimiento Dental , Torque , Humanos , Diente Molar/diagnóstico por imagen , Tomografía Computarizada de Haz Cónico/métodos , Técnicas de Movimiento Dental/instrumentación , Técnicas de Movimiento Dental/métodos , Adulto , Estudios Retrospectivos , Masculino , Femenino , Rotación , Maxilar/diagnóstico por imagen , Persona de Mediana Edad , Adulto Joven
11.
Scand J Med Sci Sports ; 34(8): e14690, 2024 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-39049546

RESUMEN

How the neuromechanics of the lower limb functional muscle groups change with running speed remains to be fully elucidated, with implications for our understanding of human locomotion, conditioning, and injury prevention. This study compared the neuromechanics (ground reaction and joint kinetics, kinematics and muscle activity) of middle-distance athletes running on an instrumented treadmill at six wide-ranging speeds (2.78-8.33 m·s-1). Ground reaction forces and kinematics were analyzed using inverse dynamics to calculate flexor and extensor joint torques, and positive and negative work done by these torques. Contributions of each functional muscle group to the total positive and negative work done by the limb during stance, swing, and the whole stride were quantified. During stance, the ankle plantar flexors were the major energy generator and absorber (>60%) at all speeds, but their contribution to whole stride energy generation and absorption declined with speed. Positive work by the hip extensors rose superlinearly with speed during stance (3-fold) and especially during swing (12-fold), becoming the biggest energy generator across the whole stride at >5 m·s-1. Knee flexor and extensor negative work also rose superlinearly with speed during swing, with the knee flexors becoming the greatest energy absorber over the whole stride at >7.22 m·s-1. Across speeds, plantar flexor peak moment and positive work accounted for 97% and 96% of the variance in step length, and swing hip extension peak moment and positive work accounted for 98% and 99% of the variance in step frequency. There were pronounced speed, phase (stance/swing), and work (positive/negative) dependent contributions of the different functional muscle groups during running, with extensive implications for conditioning and injury prevention.


Asunto(s)
Músculo Esquelético , Carrera , Humanos , Carrera/fisiología , Fenómenos Biomecánicos , Músculo Esquelético/fisiología , Masculino , Adulto , Adulto Joven , Electromiografía , Torque , Extremidad Inferior/fisiología , Articulación del Tobillo/fisiología , Femenino , Marcha/fisiología , Articulación de la Rodilla/fisiología
12.
Sensors (Basel) ; 24(13)2024 Jun 30.
Artículo en Inglés | MEDLINE | ID: mdl-39001029

RESUMEN

Quadriceps rate of torque development (RTD) and torque steadiness are valuable metrics for assessing explosive strength and the ability to control force over a sustained period of time, which can inform clinical assessments of knee function. Despite their widespread use, there is a significant gap in standardized methodology for measuring these metrics, which limits their utility in comparing outcomes across different studies and populations. To address these gaps, we evaluated the influence of sampling rates, signal filtering, and torque onset detection on RTD and torque steadiness. Twenty-seven participants with a history of a primary anterior cruciate ligament reconstruction (N = 27 (11 male/16 female), age = 23 ± 8 years, body mass index = 26 ± 4 kg/m2) and thirty-two control participants (N = 32 (13 male/19 female), age = 23 ± 7 years, body mass index = 23 ± 3 kg/m2) underwent isometric quadriceps strength testing, with data collected at 2222 Hz on an isokinetic dynamometer. The torque-time signal was downsampled to approximately 100 and 1000 Hz and processed using a low-pass, zero-lag Butterworth filter with a range of cutoff frequencies spanning 10-200 Hz. The thresholds used to detect torque onset were defined as 0.1 Nm, 1 Nm, and 5 Nm. RTD between 0 and 100 ms, 0 and 200 ms, and 40-160 ms was computed, as well as absolute and relative torque steadiness. Relative differences were computed by comparing all outcomes to the "gold standard" values computed, with a sampling rate of 2222 Hz, a cutoff frequency in the low-pass filter of 150 Hz, and torque onset of 1 Nm, and compared utilizing linear mixed models. While all combinations of signal collection and processing parameters reached statistical significance (p < 0.05), these differences were consistent between injured and control limbs. Additionally, clinically relevant differences (+/-10%) were primarily observed through torque onset detection methods and primarily affected RTD between 0 and 100 ms. Although measurements of RTD and torque steadiness were generally robust against diverse signal collection and processing parameters, the selection of torque onset should be carefully considered, especially in early RTD assessments that have shorter time epochs.


Asunto(s)
Músculo Cuádriceps , Torque , Humanos , Masculino , Femenino , Adulto , Músculo Cuádriceps/fisiología , Adulto Joven , Fuerza Muscular/fisiología , Adolescente , Reconstrucción del Ligamento Cruzado Anterior
13.
J Sports Sci ; 42(12): 1090-1098, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-39052677

RESUMEN

The purpose was to clarify the effect of individualised post-exercise blood flow restriction (PE-BFR) on measures of recovery following strenuous resistance exercise. Twenty resistance-trained adults were randomised to a PE-BFR or control (CON) group and completed a fatigue protocol of five sets of 10 repetitions of maximal intensity concentric and eccentric seated knee extension exercise. Participants then lied supine with cuffs applied to the upper thigh and intermittently inflated to 80% limb occlusion pressure (PE-BFR) or 20 mmHg (CON) for 30 min (3 × 5 min per leg). Peak torque (PT), time-to-peak torque (TTP), countermovement jump height (CMJ), muscle soreness (DOMS) and perceived recovery (PR) were measured pre-fatigue, immediately post-fatigue and at 1, 24, 48 and 72 h post-fatigue. Using a linear mixed-effect model, PE-BFR was found to have greater recovery of CMJ at 48 h (mean difference [MD]=-2.8, 95% confidence interval [CI] -5.1, 0.5, p = 0.019), lower DOMS at 48 (MD = 3.0, 95% CI 1.2, 4.9, p = 0.001) and 72 h (MD = 1.95, 95% CI -1.2, 1.5, p = 0.038) and higher PR scores at 24 (MD = -1.7, 95% CI -3.4, -0.1, p = 0.038), 48 (MD = -3.1, 95% CI -4.8, -1.5, p < 0.001) and 72 h (MD = -2.2, 95% CI -3.8, -0.5, p = 0.011). These findings suggest that individualised PE-BFR accelerates recovery after strenuous exercise.


Asunto(s)
Mialgia , Flujo Sanguíneo Regional , Entrenamiento de Fuerza , Torque , Humanos , Entrenamiento de Fuerza/métodos , Masculino , Mialgia/fisiopatología , Flujo Sanguíneo Regional/fisiología , Adulto Joven , Femenino , Adulto , Fatiga Muscular/fisiología , Músculo Esquelético/irrigación sanguínea , Músculo Esquelético/fisiología , Terapia de Restricción del Flujo Sanguíneo
14.
J Neurophysiol ; 132(2): 470-484, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-38985941

RESUMEN

Following events such as fatigue or stroke, individuals often move their trunks forward during reaching, leveraging a broader muscle group even when only arm movement would suffice. In previous work, we showed the existence of a "force reserve": a phenomenon where individuals, when challenged with a heavy weight, adjusted their motor coordination to preserve approximately 40% of their shoulder's force. Here, we investigated if such reserve can predict hip, shoulder, and elbow movements and torques resulting from an induced shoulder strength deficit. We engaged 20 healthy participants in a reaching task with incrementally heavier dumbbells, analyzing arm and trunk movements via motion capture and joint torques through inverse dynamics. We simulated these movements using an optimal control model of a 3-degree-of-freedom upper body, contrasting three cost functions: traditional sum of squared torques, a force reserve function incorporating a nonlinear penalty, and a normalized torque function. Our results demonstrate a clear increase in trunk movement correlated with heavier dumbbell weights, with participants employing compensatory movements to maintain a shoulder force reserve of approximately 40% of maximum torque. Simulations showed that while traditional and reserve functions accurately predicted trunk compensation, only the reserve function effectively predicted joint torques under heavier weights. These findings suggest that compensatory movements are strategically employed to minimize shoulder effort and distribute load across multiple joints in response to weakness. We discuss the implications of the force reserve cost function in the context of optimal control of human movements and its relevance for understanding compensatory movements poststroke.NEW & NOTEWORTHY Our study reveals key findings on compensatory movements during upper limb reaching tasks under shoulder strength deficits, as observed poststroke. Using heavy dumbbells with healthy volunteers, we demonstrate how forward trunk displacement conserves around 40% of shoulder strength reserve during reaching. We show that an optimal controller employing a cost function combining squared motor torque and a nonlinear penalty for excessive muscle activation outperforms traditional controllers in predicting torques and compensatory movements in these scenarios.


Asunto(s)
Movimiento , Hombro , Torque , Humanos , Masculino , Femenino , Adulto , Hombro/fisiología , Movimiento/fisiología , Fuerza Muscular/fisiología , Fenómenos Biomecánicos/fisiología , Adulto Joven , Músculo Esquelético/fisiología , Desempeño Psicomotor/fisiología , Brazo/fisiología , Torso/fisiología
15.
Neuroimage ; 297: 120746, 2024 Aug 15.
Artículo en Inglés | MEDLINE | ID: mdl-39033789

RESUMEN

The effectiveness of motor imagery (MI) training on sports performance is now well-documented. Recently, it has been proposed that a single session of MI combined with low frequency sound (LFS) might enhance muscle activation. However, the neural mechanisms underlying this effect remain unknown. We set up a test-retest intervention over the course of 2 consecutive days to evaluate the effect of (i) MI training (MI, n = 20), (ii) MI combined with LFS (MI + LFS, n = 20), and (iii) a control condition (CTRL, n = 20) on force torque produced across repeated maximal voluntary contractions of the quadriceps before (Pretest), after (Posttest) and at +12 h (Retention) post-intervention. We collected the integrated electromyograms of the quadriceps muscles, as well as brain electrical potentials during each experimental intervention. In the CTRL group, total force torque decreased from Pretest to Retention and from Posttest to Retention. By contrast, there was an increase between Posttest and Retention in both MI + LFS and MI groups (both ηP2 = 0.03, p < 0.05). Regression analyses further revealed a negative relationship between force performance and EEG activity in the MI + LFS group only. The data support a transient interference of LFS on cortical activity underlying the priming effects of MI practice on force performance. Findings are discussed in relation to the potential for motor reprogramming through MI combined with LFS.


Asunto(s)
Electromiografía , Músculo Cuádriceps , Humanos , Masculino , Adulto , Adulto Joven , Músculo Cuádriceps/fisiología , Electroencefalografía , Imaginación/fisiología , Femenino , Desempeño Psicomotor/fisiología , Estimulación Acústica , Torque
16.
J Sport Rehabil ; 33(6): 423-436, 2024 Aug 01.
Artículo en Inglés | MEDLINE | ID: mdl-39032923

RESUMEN

CONTEXT: The aim of this study was to investigate the effects of 8-week ballistic-strength-training program using a validated specific throwing device (ie, Arm/Shoulder Specific Strength Device), on isokinetic shoulders' rotation muscle-torques and ratios as well as range of motion in team handball players. DESIGN: A repeated-measures experimental design with a randomized controlled trial was used. METHODS: Twenty-six high-level competitive male U-19 team handball players were randomly assigned into training (TG, n = 15) and control (n = 11) groups. The TG undertook a twice a week for 8-week periodized throws program with an individually predetermined optimal load. The program incorporated shackled eccentric and concentric exercises using the Arm/Shoulder Specific Strength Device. Peak torques, functional, and conventional ratios for both arms at different angular velocities (60°·s-1, 180°·s-1, and 300°·s-1) were assessed over time and between groups, using an isokinetic dynamometer. RESULTS: A significant improvement for TG (P < .01; d = 1.13 [moderate]; +20.2%) of the concentric peak torques for dominant arm in external rotation was observed at 300°·s-1. Significant (P < .05-.01) increases were also noted for nondominant arm at the 3 studied angular velocities. In addition, 300°·s-1 eccentric peak torques of the dominant arm and nondominant arm have significantly improved for both external and internal rotations (P < .05; d = .99 [moderate] and d = 1.21 [large]; +15.7% and + 17.9%, respectively) with small changes at the other angular assessed velocities. Posttraining, TG's dominant arm showed significant improvements (P < .05-.01) in functional and conventional ratios at all velocities. Notably, significant differences (P < .05-.01) were observed at 60°·s-1 and across all velocities when comparing the TG with the control group. TG showed significant increase for internal rotation and external rotation shoulder range of motions (P < .05; d = 1.22-1.27 [large]), +5.0% and +7.7%, respectively). CONCLUSIONS: The specific 8-week throwing training program on the Arm/Shoulder Specific Strength Device showed significant performance improvements in almost all assessed isokinetic concentric and eccentric peak torques as well as internal and external range of motion increase for both arms while ensuring rotator cuff torque ratios and shoulder mobility in team handball real sport-specific condition.


Asunto(s)
Fuerza Muscular , Músculo Esquelético , Rango del Movimiento Articular , Entrenamiento de Fuerza , Hombro , Torque , Humanos , Masculino , Entrenamiento de Fuerza/instrumentación , Entrenamiento de Fuerza/métodos , Adulto Joven , Rango del Movimiento Articular/fisiología , Hombro/fisiología , Músculo Esquelético/fisiología , Fuerza Muscular/fisiología , Rotación , Dinamómetro de Fuerza Muscular
17.
J Int Med Res ; 52(7): 3000605241262186, 2024 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-39053453

RESUMEN

OBJECTIVE: Existing isokinetic contractions are characterized using standardized angular velocities, which can induce differing adaptations. Here, we characterized the variation in the isokinetic parameters of knee extensors according to individualized angular velocity (IAV). METHODS: We performed a cross-sectional study of 19 young, healthy men. We measured the maximum angular velocity (MAV) of concentric knee extension using the isotonic mode of an isokinetic dynamometer. Isometric and isokinetic (at angular velocities corresponding to 100%, 70%, 40%, and 10% of each individual's MAV) knee extensor contractions were performed, and the peak torque and mean power were recorded. RESULTS: Peak torque significantly decreased with increasing IAV (129.42 ± 25.04, 84.37 ± 20.97, and 56.42 ± 16.18 Nm at 40%, 70%, and 100%, respectively), except for isometric contraction (233.36 ± 47.85) and at 10% of MAV (208 ± 48.55). At the mean power, 10% of MAV (74.52 ± 20.84 W) was significantly lower than the faster IAV (176.32 ± 49.64, 161.53 ± 56.55, and 145.95 ± 50.64 W at 40%, 70%, and 100%, respectively), and 100% was significantly lower than 40%. CONCLUSION: The optimized IAV for isokinetic contraction to improve power output while maintaining torque is 10% to 40% of MAV. IAV may reflect both the velocity and force components of power because individuals do not have the same angular velocity.


Asunto(s)
Contracción Isométrica , Rodilla , Músculo Esquelético , Torque , Humanos , Masculino , Adulto Joven , Contracción Isométrica/fisiología , Adulto , Estudios Transversales , Músculo Esquelético/fisiología , Rodilla/fisiología , Fuerza Muscular/fisiología , Articulación de la Rodilla/fisiología , Fenómenos Biomecánicos/fisiología , Contracción Muscular/fisiología
18.
Scand J Med Sci Sports ; 34(6): e14683, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38898582

RESUMEN

Our previous study showed that daily six maximal eccentric contractions that were performed 5 days a week for 4 weeks increased maximal voluntary isometric (MVC-ISO), concentric (MVC-CON), and eccentric contraction (MVC-ECC) strength of the elbow flexors and muscle thickness of biceps brachii and brachialis (MT) by 8.3 ± 4.9%, 11.1 ± 7.4%, 13.5 ± 11.5%, and 10.6 ± 5.1%, respectively. In the present study, we tested the hypothesis that the muscle strength and MT would still increase when the training intensity was reduced to 2/3 or 1/3 of the peak MVC-ECC torque. Thirty-six healthy young (19-24 years) adults who had not performed resistance training were placed to three groups (n = 12/group): 2/3MVC or 1/3MVC that performed six eccentric contractions with 2/3 or 1/3 MVC-ECC load using a dumbbell 5 days a week for 4 weeks or control group that did not perform any training. Changes in the MVC-ISO, MVC-CON, MVC-ECC torque, and MT before and after the 4-week period were compared among the groups and with the group of the previous study in which six maximal eccentric contractions were performed 5 days a week for 4 weeks (MVC group; n = 12). The control and 1/3MVC groups showed no significant changes in any measures. Significant (p < 0.05) increases in MVC-ISO (10.3 ± 11.4%), MVC-CON (10.9 ± 9.5%), and MVC-ECC (9.3 ± 8.8%) torque and MT (10.1 ± 9.2%) were observed for the 2/3MVC group. These changes were not significantly different from those of the MVC group. These results suggest that the 2/3-intensity eccentric contractions with a dumbbell are as effective as maximal-intensity isokinetic eccentric contractions to induce muscle adaptations.


Asunto(s)
Contracción Isométrica , Fuerza Muscular , Músculo Esquelético , Torque , Humanos , Fuerza Muscular/fisiología , Adulto Joven , Masculino , Músculo Esquelético/fisiología , Femenino , Contracción Isométrica/fisiología , Entrenamiento de Fuerza/métodos , Contracción Muscular/fisiología , Codo/fisiología
19.
PeerJ ; 12: e17508, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38854796

RESUMEN

Objectives: Low back pain (LBP) is common in elite athletes. Several peripheral and central factors have been identified to be altered in non-athletic LBP populations, however whether these alterations also exist in elite athletes with LBP is unknown. The aim of this study was to determine whether elite basketballers with a history of persistent LBP perform worse than those without LBP at a lumbar muscle endurance task, a lumbar extension peak-torque task, and a lumbar motor imagery task. Method: An observational pilot study. Twenty junior elite-level male basketballers with (n = 11) and without (n = 9) a history of persistent LBP were recruited. Athletes completed a lumbar extensor muscle endurance (Biering-Sorensen) task, two lumbar extensor peak-torque (modified Biering-Sorensen) tasks and two motor imagery (left/right lumbar and hand judgement) tasks across two sessions (48 hours apart). Performance in these tasks were compared between the groups with and without a history of LBP. Results: Young athletes with a history of LBP had reduced lumbar extensor muscle endurance (p < 0.001), reduced lumbar extension peak-torque (p < 0.001), and were less accurate at the left/right lumbar judgement task (p = 0.02) but no less accurate at a left/right hand judgement task (p = 0.59), than athletes without a history of LBP. Response times for both left/right judgement tasks did not differ between groups (lumbar p = 0.24; hand p = 0.58). Conclusions: Junior elite male basketballers with a history of LBP demonstrate reduced lumbar extensor muscle endurance and lumbar extension peak-torque and are less accurate at a left/right lumbar rotation judgement task, than those without LBP.


Asunto(s)
Baloncesto , Dolor de la Región Lumbar , Región Lumbosacra , Resistencia Física , Humanos , Dolor de la Región Lumbar/fisiopatología , Baloncesto/fisiología , Masculino , Proyectos Piloto , Adolescente , Resistencia Física/fisiología , Torque , Atletas , Músculo Esquelético/fisiopatología , Músculo Esquelético/fisiología
20.
Sci Robot ; 9(91): eadi2377, 2024 Jun 12.
Artículo en Inglés | MEDLINE | ID: mdl-38865477

RESUMEN

Repetitive overhead tasks during factory work can cause shoulder injuries resulting in impaired health and productivity loss. Soft wearable upper extremity robots have the potential to be effective injury prevention tools with minimal restrictions using soft materials and active controls. We present the design and evaluation of a portable inflatable shoulder wearable robot for assisting industrial workers during shoulder-elevated tasks. The robot is worn like a shirt with integrated textile pneumatic actuators, inertial measurement units, and a portable actuation unit. It can provide up to 6.6 newton-meters of torque to support the shoulder and cycle assistance on and off at six times per minute. From human participant evaluations during simulated industrial tasks, the robot reduced agonist muscle activities (anterior, middle, and posterior deltoids and biceps brachii) by up to 40% with slight changes in joint angles of less than 7% range of motion while not increasing antagonistic muscle activity (latissimus dorsi) in current sample size. Comparison of controller parameters further highlighted that higher assistance magnitude and earlier assistance timing resulted in statistically significant muscle activity reductions. During a task circuit with dynamic transitions among the tasks, the kinematics-based controller of the robot showed robustness to misinflations (96% true negative rate and 91% true positive rate), indicating minimal disturbances to the user when assistance was not required. A preliminary evaluation of a pressure modulation profile also highlighted a trade-off between user perception and hardware demands. Finally, five automotive factory workers used the robot in a pilot manufacturing area and provided feedback.


Asunto(s)
Diseño de Equipo , Rango del Movimiento Articular , Robótica , Hombro , Torque , Dispositivos Electrónicos Vestibles , Humanos , Robótica/instrumentación , Fenómenos Biomecánicos , Masculino , Hombro/fisiología , Adulto , Rango del Movimiento Articular/fisiología , Músculo Esquelético/fisiología , Electromiografía/instrumentación , Industrias/instrumentación , Lesiones del Hombro/prevención & control , Femenino , Adulto Joven , Análisis y Desempeño de Tareas , Articulación del Hombro/fisiología , Dispositivo Exoesqueleto
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...